Top Banner
X-ray Production
39

X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Dec 17, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

X-ray Production

Page 2: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Crookes’ Tube

PLATES FORHORIZONTAL DEFLECTION

PLATES FORVERTICAL DEFLECTION

ELECTRON GUN

ELECTRON BEAM

FLUORESCENTSCREEN

PHOTOGRAPHICPLATE

Roentgen’s discovery based on Crookes’ tube r

Page 3: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Electromagnetic RadiationRadiation may be defined as energy in transit from onelocation to another.

The Nature of X-Rays:

• X-rays, light, radio waves, ultraviolet rays, are electromagnetic radiation;

• electromagnetic Radiation can be produced by accelerating an electric charge;

. It has an associated electric and magnetic field.

Page 4: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

EM Radiation

Page 5: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.
Page 6: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Particle-wave duality of x-ray

• X-rays, as well as all other electromagnetic radiation, have the wave-particle duality;

• This wave can be described by its frequency (or wavelength ) and traveling velocity c.• c=3 x 108 m/sec (velocity in a vacuum)

c = c

Page 7: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

مثال : فركانس يك فتون پرتو ايكس با چقدر است ؟KeV 70انرژي

Hz 19101.69

Sec 101.69 evSec 104.15

ev 1070 ,

h

E , hE 119

15

3

EEk = = h c EEk = = hc / h = 4.15 * 10-15 ev-Sec

Page 8: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Electromagnetic Radiation Spectrum

Page 9: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

X rays generation

X rays are generated by interactions between the energetic electrons and atoms of the target.

The interactions result x rays in two ways:

(1)Bremsstrahlung (brake radiation, general radiation);

(2) Characteristic radiation

Page 10: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Bremsstrahlung (brake radiation, general radiation)

when a charged particle undergoes acceleration or deceleration, it emits photons.

Page 11: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Most electrons that strike the target give up their energy by interactions with a number of atoms;

Conclusion: The bremsstrahlung produces inherently continuous spectrum of x rays.

99% of the radiation are absorbed by target and the walls of the x-ray tube to produce only heat.

Bremmstrahlung

Page 12: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

For monoenergetic electrons passing through a thick target, the energy flounce spectrum is:

•kinetic energy = EEk= = h

= c / min=12.4/kVp A0

Bremmstrahlung

Page 13: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

حداكـــثر انرژي فتون x زماني اتفاق مي افتــد كه الكترون توسط اولين اتم متوقف شود در نتيجـه

فوتونـــي با حداقل طول مــوج ايجاد مي شود و بستگـــي به اختالف پتانسيل (High Voltage) يعني

KVp.دارد

بعنوان مثال طول موج X-ray با KVp=100 برابر است با :

oA 0.124nm 0.0124=100

1.24

kvp

1.24

min

•X-ray tube voltage is expressed as the peak kilovoltage (kVp). (eg; 100 kVp)

Page 14: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

•The minimum energy required to “knocking out” an electron in a specific orbit depends on binding energy.

Characteristic radiation

•Removal of an electron cause the target atom to a higher energy state with 2 productions:

1) Positive charged ion2) Negative charged ion

Two ways for an ionized atom returning to its normal (lower energy) state: (1) Characteristic x-ray radiation; (2) Emission of Auger electrons.

Page 15: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Characteristic x-ray

Page 16: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

K-shell filling is the most important for diagnostic x rays. For tungsten:This energy is ~70 keV for K shell.L-characteristic x-ray is ~11 keV.Ek-L= 59 (keV).

- It is ~ 10% of total spectrum-The low-energy photons are absorbed by the target and the walls of the x-ray tube to produce heat.

Characteristic radiation:

Page 17: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

K-Characteristic Radiation

12

1

1

K

L

M

N

K K K

Photon Energy (keV)

Page 18: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.
Page 19: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

فاكتورهائي كه در طيف اشعه : ايكس موCثر هستند عبارتند از

1 جنس مادى هدف -2 ولتاژ اعمال شده - (KVp) 3 جريان المپ اشعة ايكس -4 تأثير فيلتر ) صافي ( اضافي -5 اثر لبة -K 6 تأثير شكل موجي ولتاژ -

Page 20: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

X- rays Tube Bombardment must take place in a vacuum to prevent •Ionization of air.

Tungsten Target

Evacuated Envelope

AnodeElectrons

Cathode (heated tungsten filament)

Page 21: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

X-ray Tube

Page 22: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

اشعه كامل المپ با xساختماندوار آند

Page 23: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Disk-shaped, rotating anode allows heat to be spread over a much larger surface without compromising apparent size of focal spot.

Rotating Anode:

2 mm

7 mm

Page 24: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

What Is Happening In Cathode

For large focal spot

focusing cup

For small focal spot

cathodeelectrons

(--)

(1) Focusing cup.

Thermo ionic emission: when a metal is heated its atoms absorb thermal energy and some electrons escape the metal surface.

Page 25: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

(3) Electric circuit to provide the heating currents.This is filament circuit which is different from the x-ray tube current.

(4) Electrons are accelerated towards the anode. The x-ray tube current, measured in mA , refers to the number of electrons flowing per second from the filament to anode.

(2) Tungsten filament :

Filament is made of tungsten wire with high melting point (3370C), low vaporization, and lasting strength.

Page 26: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

What Is Happening In Anode

High-speed electrons collide with the tungsten atoms.

cathode

(--)

(+)

X-Rays

ElectronsTungsten Target

Page 27: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Angulation of anode

allows to deposit electron energy over larger surface of anode while maintaining smaller apparent focal spot size. (Typical anode angle 6- to 20-degree).

cathode

(--)(+)

X-Rays

ElectronsTungsten Target

Cu

Sin20° = 0.342, Sin16.5 =0.284Titling angle

Apparent focal spot size

Page 28: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Heel effect

x-ray beam produced in target is attenuated in anode body,

therefore its intensity is not constant over the entire field of coverage.

(X-ray intensity is diminished toward the direction of anode).

Page 29: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.
Page 30: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

X-ray Generator

•Electric power is needed in a x-ray tube for three objectives:(1) To boil off the electrons from the filament; (2) To accelerate electrons; (3) To control the exposure time.

•The x-ray generator has a circuit for each of these objectives:(1) Filament circuit;(2) High-voltage circuit;(3) Time circuit

•Two compartments Control panel : Exposure switching, Exposure timer. Transformer assembly : Voltage transformers, Current rectifiers.

Page 31: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

~

X-ray generator

•Voltage transformers provide low-voltage (~ 10 V ) for the filament current• and high-voltage ( ~ 150, 000 V) for the cathode-anode tube.

Principle of transformer: Changing magnetic field induces electric currentsV

primary coil

secondary coil

Vp/Vs=Np/Ns

Page 32: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Full-wave and half-wave rectification

half-wave rectification

full-wave rectification

input wave form

Page 33: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

X-ray Tube Chart

Heat Unit (HU) = kV.mA.S

For example a 70 kV @100 mA

Heat UnitsSingle phase 700Constant potential 980

A X-ray tube chart is used to determine the safe limit to operate the x-ray tube

Page 34: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Xray Tube Rating ChartFor example, a 35-kW X-ray tube can only accept 500 mA for

0.1 sec exposure at 70 kVp.

Page 35: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.

Useful Formulas

keV, kVP , S (sec), and mA are the units particularly suited to x-ray physics.

E(keV) = 12.4/(angstrom)1 angstrom =10-10 m1 eV = 1.6 X 10-19 joules1 e = 1.6 X 10-19 coulombs1 joule = 1 coulomb X 1V1 cal = 4.184 joule1 ampere = 1 coulomb/sec

Page 36: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.
Page 37: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.
Page 38: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.
Page 39: X-ray Production. Crookes’ Tube PLATES FOR HORIZONTAL DEFLECTION PLATES FOR VERTICAL DEFLECTION ELECTRON GUN ELECTRON BEAM FLUORESCENT SCREEN PHOTOGRAPHIC.