Top Banner
World Class Oil & Gas Cables Gexol Gexol ®
36

World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

Jun 15, 2018

Download

Documents

truongthu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

WWoorrlldd CCllaassss OOiill && GGaass CCaabblleessGexolGexol

®

Page 2: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33

Ester Based Mud Resistant Cable . . . . . . . . . 30-31

General Information• Ampacity Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Bend Radius . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Hawke Gland Types . . . . . . . . . . . . . . . . . . . . . . . . . . 1• Gexol Cable Stranding Profile . . . . . . . . . . . . . . . . . . 2

Instrumentation Cable. . . . . . . . . . . . . . . . . . . . 15-18• Individually Shielded Pairs. . . . . . . . . . . . . . . . 15 - 16• Individually Shielded Triads . . . . . . . . . . . . . . . 17 - 18

Multi-Conductor Control Cable . . . . . . . . . . . . 13-14

Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12• Single Conductor . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4• Two Conductor . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6• Three Conductor . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 8• Four Conductor . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 10• Five Conductor. . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12

Type MMV Medium Voltage Power Cable . . 21-29

Type VFD Power Cable• Standard Gexol Insulated VFD Cable . . . . . . . . 19-20• MMV VFD Cable. . . . . . . . . . . . . . . . . . . . . . . . . 27-28

Assembly Solutions . . . . . . . . . . . . . . . . . . . . . . . . . 32

®

AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listedis approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application.

� Fastest Lead Times• Standard 6 - 8 weeks• Emergency 2 - 4 weeks

� Best On-Time Delivery Rate*

� Highest Ampacity Ratings• DNV: 95°C• ABS: 100°C• Lloyd’s: 95°C

� Extremely Flexible

*Visit www.AmerCable.com for our most current on time delivery rate

Flame RetardantCertified to IEC 92-3 (332-3A)

and IEEE 1580

Severe Cold DurabilityExceeds CSA Cold Bend / Cold Impact (-40°C/-35°C)

Oil ResistantDrilling Mud Resistant

Gexol® is a registered trademark of AmerCable Incorporated. Registered in the U.S. Patent and Trademark Office. © 2009 AmerCable Incorporated

Page 3: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

1

Diameter Conversion ➡ (inches to millimeters): Multiply by 25.4

Bend RadiusUnarmored Armored Armored & Sheathed

IEEE 45 6X Diameter 8X Diameter 8X Diameter

IEC 92 <1" (25mm) 6X Diameter 8X Diameter4 x Diameter>1" (25mm)6X Diameter

Transport <1" (25mm) 6X Diameter 6X DiameterCanada 4X Diameter

>1" (25mm)6X Diameter

Gexol® Insulated Oil & Gas Cables are the industry’s standard for premiumpower, control and instrumentationperformance. Gexol cables prove their value daily in the punishing operatingenvironments of offshore drilling andpetroleum facilities around the world.

Offshore applications challenge cableconstruction with relentless heat,vibration, salt corrosion, drilling mud and mechanical stress. And reliability is a huge issue – because it’s a long,long way to the nearest cable warehouse. You can depend on Gexol Insulated Oil & Gas cables for safe, reliable performance in theharshest operating conditions.

HawkeGland Types Unarmored Armored & SheathedIndustrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Hawke Gland Types

110°C (Free Air) Ratings Based on IEEE Std. 835-1994 for isolated cables in freeair with full sun, 2 ft/s air movement, and a 45°C ambient.

110°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 110°C ampacities should be multiplied by 0.8.

100°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the 100°C ampacities should be multiplied by 0.8.

95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU rules and a 45°C ambient.

• Ampacities for four conductor cables are based on one conductor not acting as a normal current-carrying conductor (e.g., grounded neutral or grounding conductor).

• For free air ratings, the IEEE Std. 45 numbers can be divided by 0.85

Ampacity Ratings

®

Oil & Gas Cables

Page 4: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

Individual Closest Equivalent UninsulatedSize Number Strand Dia. IEEE 45 Metric Size Conductor

AWG/kcmil of Strands (inches) Std. Size (mm2) Dia. (inches)

181614121086421

1/02/03/04/0

262313373444535646777

1111

19191919373761

133133209266342418532646777925

11101332159119242745

0.0100 0.0117 0.0147 0.01850.01670.0201 0.0201 0.01770.0223 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.02010.0201 0.0201 0.0201 0.0201 0.0201

2346

101626416683

106133168212262313373444535646777

1111

0.96 1.32 2.083.29 5.23 7.57

12.49 21.11 33.51 42.7954.45 70.01 85.57

108.91 132.25159.06 189.36227.23272.68325.70393.87561.94

0.0490.059 0.0740.093 0.113 0.1360.1750.2580.3240.361 0.4070.4610.510 0.5750.6540.720 0.7850.8600.9411.0291.1321.354

Gexol Insulated Power, Control andInstrumentation Cable

SSttrraannddiinngg PPrrooffiillee

Gexol Insulated Power, Control andInstrumentation Cable

SSttrraannddiinngg PPrrooffiilleeOil & Gas Cables

2

Flame RetardantCertified to IEC 92-3 (332-3A)

and IEEE 1580

Severe Cold DurabilityExceeds CSA Cold Bend / Cold Impact (-40°C/-35°C)

Oil ResistantDrilling Mud Resistant

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 5: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

3

37-102

Single Conductor Power CableGexol® InsulatedExtremely Flexible • 600V or 2kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� NVE 95/1696, FAL� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS) 91/60333 (E6)� American Bureau of Shipping (ABS) 99-BT5905-X� UL Listed as Marine Shipboard Cable (E111461) � United States Coast Guard November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

ApplicationDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.

Features� High strand count conductors make this product much

more flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higher insulationresistance reduces electrical losses.

� Gexol’s excellent resistance to moisture produces stableelectrical properties throughout the life of the cable.

� In a fire condition, Gexol’s nonchlorinated flame retardantsystem produces less toxic and less corrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV 95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA cold bend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.� Suitable for use in Class I, Division 1 and Zone 1

environments (armored and sheathed).� Optional braid armor of bronze or tinned copper.

Insulation/JacketGEXOL® cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.2000V/IEC 1000V.

Armor (Optional)Basket weave wirearmor per IEEE 1580 and UL1309/CSA 245. Bronze standard.Tinned copperavailable by request.

ConductorSoft annealedflexible strandedtinned copper perIEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compound meeting UL 1309/CSA 245 andIEEE 1580.

®

Oil & Gas Cables

Size Unarmored Inductive Voltage Drop DC Resistance AC Resistance at AmpacityAWG/ Part No. Diameter Weight Reactance at 110°C at 25°C 110°C, 60 Hz Free Airkcmil 37-102 (inches) (lbs/MFt.) (Ohms/k ft.) (Volts/Amp/kft.) (Volts/Amp/kft.) (Ohms/k ft.) 110°C 110°C 100°C 95°C18 -151 0.143 16 0.046 13.560 7.210 9.763 30 17 16 2016 -153 0.153 18 0.044 8.516 4.520 6.121 35 25 23 2314 -154 0.168 25 0.041 5.383 2.850 3.859 41 40 37 3212 -156 0.187 32 0.038 3.394 1.790 2.424 64 48 45 3810 -158 0.207 51 0.036 2.155 1.130 1.530 85 62 58 518 -159 0.255 71 0.036 1.338 0.694 0.940 112 77 72 686 -160 0.295 108 0.034 0.852 0.436 0.590 148 103 96 914 -162 0.377 173 0.030 0.583 0.286 0.399 196 137 128 1212 -164 0.443 242 0.029 0.368 0.175 0.244 259 181 169 1621 -165 0.484 335 0.029 0.301 0.140 0.195 298 208 194 187

1/0 -166 0.548 420 0.029 0.246 0.111 0.156 344 243 227 2172/0 -167 0.615 494 0.028 0.202 0.089 0.125 396 281 262 2503/0 -168 0.663 734 0.028 0.167 0.070 0.100 457 321 300 289

600VUnarmored

(2kV on next page)

Page 6: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

4

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 80

0-50

6-94

73 •

713-

896-

5800

• Fa

x: 7

13-8

49-9

009

1063

3 W

est L

ittle

Yor

k • B

ldg.

#1

• Sui

te #

100

• Hou

ston

, TX

7704

1 • w

ww

. am

erca

ble.

com

*Una

rmor

ed 3

/0 a

nd s

mal

ler h

as a

jack

et p

er U

L130

9 &

IEEE

1580

Cabl

e di

amet

ers

show

n as

nom

inal

are

sub

ject

to a

±5%

man

ufac

turin

g to

lera

nce

Orde

ring

Gexo

l Oil

& G

as C

able

sEx

ampl

e:

• Sin

gle

cond

ucto

r pow

er c

able

• 2kV

100

%• 5

35 k

cmil

• bro

nze

arm

ored

& s

heat

hed

Amer

Cabl

e Ge

xol

Oil &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(from

cha

rts)

Arm

or R

equi

rem

ent

BS –

arm

ored

&sh

eath

edBl

ank

– no

arm

or

37–1

02–

124

BS

See

page

2 fo

r Stra

ndin

g Pr

ofile

37-1

02

Sing

le C

ondu

ctor

Pow

er C

able

Gexo

l®In

sula

ted

Extre

mel

y Fl

exib

le •

2kV

• Rat

ed 1

10°C

2kV

– Fl

exib

le P

ower

Cab

le –

Sin

gle

Cond

ucto

rAr

mor

ed a

ndUn

arm

ored

Arm

ored

(B)

Shea

th (B

S)Si

zeUn

arm

ored

Diam

eter

Nom

inal

Nom

inal

Indu

ctiv

eVo

ltage

Dro

pDC

Res

ista

nce

AC R

esis

tanc

e at

Ampa

city

AWG/

Part

No.

Diam

eter

Wei

ght

Unde

r Arm

orW

eigh

t Di

amet

erW

eigh

tDi

amet

erW

eigh

tRe

acta

nce

at 1

10°C

at

25°

C11

0°C,

60 H

zFr

ee A

irkc

mil

mm

237

-102

(inch

es)

(lbs/

MFt

.)(in

ches

)(lb

s/M

Ft.)

(inch

es)

(lbs/

MFt

.)(in

ches

)(lb

s/M

Ft.)

(Ohm

s/10

00 ft

.)(V

olts

/Am

p/10

00 ft

.)(O

hms/

1000

ft.)

(Ohm

s/10

00 ft

.)11

0°C

110°

C10

0°C

95°C

181.

0-1

010.

232*

290.

143

160.

193

290.

324

380.

065

13.5

807.

210

9.76

330

1716

2016

1.3

-102

0.24

5*34

0.15

318

0.20

332

0.33

442

0.06

28.

535

4.52

06.

121

3525

2323

142.

1-1

050.

259*

420.

168

250.

218

450.

349

600.

057

5.40

12.

850

3.85

941

4037

3212

3.3

-106

0.28

1*53

0.18

732

0.23

758

0.36

880

0.05

33.

410

1.79

02.

424

6448

4538

105.

2-1

080.

302*

680.

207

510.

257

930.

388

127

0.05

02.

170

1.13

01.

530

8562

5851

87.

6-1

090.

354*

950.

255

710.

305

116

0.43

615

90.

048

1.35

10.

694

0.94

011

277

7268

612

.5-1

100.

384*

130

0.29

510

80.

345

155

0.47

620

40.

045

0.86

40.

436

0.59

014

810

396

914

21-1

120.

484*

210

0.37

717

30.

427

230

0.55

829

60.

039

0.59

30.

286

0.39

919

613

712

812

12

34-1

140.

576*

314

0.44

324

20.

493

303

0.62

436

50.

037

0.37

60.

175

0.24

425

918

116

916

21

43-1

150.

629*

393

0.48

433

50.

534

406

0.66

546

80.

036

0.30

70.

140

0.19

529

820

819

418

71/

054

-116

0.68

7*48

50.

548

420

0.59

849

40.

729

571

0.03

50.

253

0.11

10.

156

344

243

227

217

2/0

70-1

170.

737*

596

0.61

549

40.

665

579

0.79

666

20.

034

0.20

80.

089

0.12

539

628

126

225

03/

086

-118

0.78

8*70

90.

663

627

0.71

377

60.

886

900

0.03

40.

174

0.07

00.

100

457

321

300

289

4/0

109

-119

0.81

082

00.

810

820

0.86

088

91.

038

1036

0.03

30.

145

0.05

60.

080

528

376

351

335

262

132

-120

0.88

894

50.

888

945

0.93

811

471.

111

1295

0.03

40.

127

0.04

60.

067

599

436

407

382

313

159

-121

0.95

411

130.

954

1113

1.00

413

321.

177

1491

0.03

30.

112

0.03

80.

056

604

487

455

427

373

189

-122

1.01

814

191.

018

1419

1.06

815

761.

241

1741

0.03

20.

099

0.03

20.

047

674

553

516

476

444

227

-123

1.09

415

781.

094

1578

1.14

418

161.

317

1992

0.03

10.

089

0.02

70.

041

750

630

588

531

535

273

-124

1.21

219

761.

212

1976

1.26

222

461.

435

2425

0.03

10.

081

0.02

20.

035

839

709

630

597

646

326

-126

1.30

023

481.

300

2348

1.35

025

591.

523

2757

0.03

10.

073

0.01

90.

030

937

783

731

671

777

394

-127

1.39

527

951.

395

2795

1.44

530

131.

618

3205

0.03

00.

067

0.01

50.

026

1048

881

822

753

1111

562

-129

1.66

839

821.

668

3982

1.71

841

291.

954

4484

0.03

00.

056

0.01

10.

018

1303

1098

1025

937

Oil &

Gas

Cab

les

Page 7: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

5

37-102

Two Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

JacketA black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosettingcompound meeting UL 1309/CSA 245 andIEEE 1580.

InsulationGEXOL® cross-linkedflame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.Color code:Black-White

ConductorSoft annealedflexible strandedtinned copper perIEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.

Armor (Optional)Basket weave wire armorper IEEE 1580 and UL1309/CSA 245. Bronzestandard. Tinned copperavailable by request.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 8: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

6

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Cab

le d

iam

eter

s sh

own

as n

omin

al a

re s

ubje

ct t

o a

±5%

man

ufac

turin

g to

lera

nce

Arm

ored

and

Unar

mor

edAr

mor

ed (B

)Sh

eath

(BS)

Size

Nom

inal

Nom

inal

Nom

inal

AC R

esis

tanc

eIn

duct

ive

Volta

ge D

rop

AWG/

Part

No.

Diam

eter

Wei

ght

Diam

eter

Wei

ght

Diam

eter

Wei

ght

DC R

esis

tanc

e at

110°

C, 6

0 Hz

Reac

tanc

e11

0°C

Ampa

city

kcm

ilm

m2

37-1

02(in

ches

)(lb

s/M

Ft.)

(inch

es)

(lbs/

MFt

.)(in

ches

)(lb

s/M

Ft.)

25°C

(Ohm

s/10

00 ft

.)(O

hms/

1000

ft.)

(Ohm

s /1

000

ft.)

(Vol

ts/A

mp/

1000

ft.)

110°

C10

0°C

95°C

161.

3-5

010.

350

750.

400

141

0.54

020

24.

610

6.12

10.

039

8.51

120

1920

142.

1-5

070.

380

840.

430

165

0.56

123

02.

907

3.85

90.

036

5.37

933

3127

123.

3-5

150.

420

111

0.47

019

00.

601

263

1.82

62.

424

0.03

43.

390

4340

3210

5.2

-553

0.46

014

60.

510

230

0.64

130

71.

153

1.53

00.

032

2.15

153

4943

87.

6-2

090.

600

221

0.65

032

70.

781

416

0.70

80.

940

0.03

41.

336

6964

586

12.5

-210

0.68

030

80.

730

424

0.90

355

90.

445

0.59

00.

032

0.85

091

8577

421

-594

0.88

751

60.

937

664

1.11

083

50.

300

0.39

90.

029

0.58

211

811

010

31/

054

-216

1.24

311

281.

293

1334

1.46

615

620.

117

0.15

60.

028

0.24

521

319

918

44/

010

9-2

191.

593

2003

1.64

322

711.

878

2680

0.05

90.

080

0.02

60.

138

329

307

285

37-1

02

Two

Cond

ucto

r Pow

er C

able

Gexo

l®In

sula

ted

Extre

mel

y Fl

exib

le •

0.6/

1kV

• Rat

ed 1

10°C

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 80

0-50

6-94

73 •

713-

896-

5800

• Fa

x: 7

13-8

49-9

009

1063

3 W

est L

ittle

Yor

k • B

ldg.

#1

• Sui

te #

100

• Hou

ston

, TX

7704

1 • w

ww

. am

erca

ble.

com

Flex

ible

Pow

er C

able

– T

wo

Cond

ucto

r

Orde

ring

Gexo

l Oil

& G

as C

able

sEx

ampl

e:

• 2 c

ondu

ctor

pow

er c

able

• 0.6

/1kV

• #4

AWG

• bro

nze

arm

ored

& s

heat

hed

Amer

Cabl

e Ge

xol

Oil &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(from

cha

rts)

Arm

or R

equi

rem

ent

BS –

arm

ored

&sh

eath

edBl

ank

– no

arm

or

37–1

02–

594

BS

Oil &

Gas

Cab

les

See

page

2 fo

r St

rand

ing

Prof

ile

Page 9: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

7

37-102

Three Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

JacketA black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245 and IEEE 1580.

ConductorSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

InsulationGEXOL® cross-linkedflame retardantpolyolefin, meeting the requirements for Type P of IEEE 1580and Type X110 of UL 1309/CSA 245.Color code:Black-White-Red

Armor (Optional)Basket weave wirearmor per IEEE 1580and UL 1309/CSA 245.Bronze standard.Tinned copperavailable by request.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronzeor tinned copper.

An uninsulated ground conductormay be incorporated on a

make-to-order basis.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 10: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

8

37-1

02

Thre

e Co

nduc

tor P

ower

Cab

leGe

xol®

Insu

late

dEx

trem

ely

Flex

ible

• 0.

6/1k

V • R

ated

110

°C

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 80

0-50

6-94

73 •

713-

896-

5800

• Fa

x: 7

13-8

49-9

009

1063

3 W

est L

ittle

Yor

k • B

ldg.

#1

• Sui

te #

100

• Hou

ston

, TX

7704

1 • w

ww

. am

erca

ble.

com

Flex

ible

Pow

er C

able

– T

hree

Con

duct

or

Cab

le d

iam

eter

s sh

own

as n

omin

al a

re s

ubje

ct t

o a

±5%

man

ufac

turin

g to

lera

nce

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Arm

ored

and

Unar

mor

edAr

mor

ed (B

)Sh

eath

(BS)

Size

Nom

inal

Nom

inal

Nom

inal

AC R

esis

tanc

eIn

duct

ive

Volta

ge D

rop

Opt.

Unin

sula

ted

AWG/

Part

No.

Diam

eter

Wei

ght

Diam

eter

Wei

ght

Diam

eter

Wei

ght

DC R

esis

tanc

e at

110°

C, 6

0 Hz

Reac

tanc

e11

0°C

Grou

ndin

g Co

nd.

Ampa

city

kcm

ilm

m2

37-1

02(in

ches

)(lb

s/M

Ft.)

(inch

es)

(lbs/

MFt

.)(in

ches

)(lb

s/M

Ft.)

25°C

(Ohm

s/10

00 ft

.)(O

hms/

1000

ft.)

(Ohm

s /1

000

ft.)

(Vol

ts/A

mp/

1000

ft.)

Size

AW

G11

0°C

100°

C95

°C16

1.3

-502

0.36

965

0.41

912

70.

519

181

4.61

06.

121

0.03

98.

511

–17

1616

142.

1-5

080.

401

102

0.45

117

60.

583

228

2.90

73.

859

0.03

65.

379

–27

2522

123.

3-5

160.

445

133

0.49

521

20.

626

276

1.82

62.

424

0.03

43.

390

–33

3127

105.

2-3

080.

488

189

0.53

828

10.

669

352

1.15

31.

530

0.03

22.

151

–44

4136

87.

6-3

090.

637

274

0.68

738

50.

818

477

0.70

80.

940

0.03

41.

336

–56

5248

612

.5-3

100.

723

390

0.77

351

90.

946

650

0.44

50.

590

0.03

20.

850

875

7064

421

-312

0.94

267

80.

992

843

1.16

510

040.

300

0.39

90.

029

0.58

28

9992

852

34-3

141.

084

987

1.13

411

601.

307

1374

0.18

40.

244

0.02

80.

366

613

112

211

31

43-3

151.

206

1234

1.25

614

581.

431

1675

0.14

70.

195

0.02

80.

299

615

314

313

11/

054

-316

1.32

614

481.

376

1781

1.55

020

150.

117

0.15

60.

028

0.24

56

176

164

152

2/0

70-3

171.

422

1945

1.47

220

821.

645

2424

0.09

30.

125

0.02

70.

200

620

118

817

53/

086

-318

1.52

823

791.

578

2720

1.81

431

060.

074

0.10

00.

027

0.16

64

234

218

202

4/0

109

-319

1.76

528

641.

815

3233

2.05

036

520.

058

0.08

00.

026

0.13

84

270

252

235

262

132

-320

1.98

034

522.

030

3880

2.26

644

340.

048

0.06

70.

026

0.11

93

315

294

267

313

159

-321

2.13

140

232.

181

4434

2.41

849

190.

040

0.05

60.

026

0.10

53

344

321

299

373

189

-322

2.23

147

722.

281

5219

2.51

757

180.

034

0.04

70.

025

0.09

23

387

361

334

444

227

-323

2.39

456

702.

444

6176

2.68

068

640.

028

0.04

10.

025

0.08

32

440

411

372

535

273

-324

2.63

767

842.

687

7492

2.98

682

500.

024

0.03

50.

026

0.07

52

498

443

418

646

326

-326

2.95

879

613.

008

8414

3.30

192

580.

020

0.03

00.

026

0.06

81

553

516

470

777

394

-327

3.16

895

733.

218

1006

53.

511

1094

50.

016

0.02

60.

026

0.06

31

602

562

529

Orde

ring

Gexo

l Oil

& G

as C

able

sEx

ampl

e:

• 3 c

ondu

ctor

pow

er c

able

• 0.6

/1kV

• bro

nze

arm

ored

& s

heat

hed

• with

gro

und

Amer

Cabl

e Ge

xol

Oil &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(from

cha

rts)

Arm

or R

equi

rem

ent

BS –

arm

ored

&sh

eath

edBl

ank

– no

arm

or

Grou

nd C

ondu

ctor

G –

with

gro

und

Blan

k –

no g

roun

d

37–1

02–

320

BSG

Oil &

Gas

Cab

les

See

page

2 fo

r St

rand

ing

Prof

ile

Page 11: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

9

37-102

Four Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

JacketA black, arctic grade, flame retardant, oil,abrasion, chemical andsunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.

InsulationGEXOL® cross-linkedflame retardant polyolefin,meeting the requirementsfor Type P of IEEE 1580and Type X110 of UL 1309/CSA 245. Color code:Black-White-Red-Green

ConductorSoft annealed flexiblestranded tinnedcopper per IEEE 1580Table 11.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA245 and IEEE 1580.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

Armor (Optional)Basket weave wire armorper IEEE 1580 and UL1309/CSA 245. Bronzestandard. Tinned copperavailable by request.

An uninsulated ground conductormay be incorporated on a

make-to-order basis.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 12: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

10

37-1

02

Four

Con

duct

or P

ower

Cab

leGe

xol®

Insu

late

dEx

trem

ely

Flex

ible

• 0.

6/1k

V • R

ated

110

°C

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 80

0-50

6-94

73 •

713-

896-

5800

• Fa

x: 7

13-8

49-9

009

1063

3 W

est L

ittle

Yor

k • B

ldg.

#1

• Sui

te #

100

• Hou

ston

, TX

7704

1 • w

ww

. am

erca

ble.

com

Flex

ible

Pow

er C

able

– F

our C

ondu

ctor

Cab

le d

iam

eter

s sh

own

as n

omin

al a

re s

ubje

ct t

o a

±5%

man

ufac

turin

g to

lera

nce

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Arm

ored

and

Unar

mor

edAr

mor

ed (B

)Sh

eath

(BS)

Size

Nom

inal

Nom

inal

Nom

inal

AC R

esis

tanc

eIn

duct

ive

Volta

ge D

rop

Opt.

Unin

sula

ted

AWG/

Part

No.

Diam

eter

Wei

ght

Diam

eter

Wei

ght

Diam

eter

Wei

ght

DC R

esis

tanc

e at

110°

C, 6

0 Hz

Reac

tanc

e11

0°C

Grou

ndin

g Co

nd.

Ampa

city

kcm

ilm

m2

37-1

02(in

ches

)(lb

s/M

Ft.)

(inch

es)

(lbs/

MFt

.)(in

ches

)(lb

s/M

Ft.)

25°C

(Ohm

s/10

00 ft

.)(O

hms/

1000

ft.)

(Ohm

s /1

000

ft.)

(Vol

ts/A

mp/

1000

ft.)

Size

AW

G11

0°C

100°

C95

°C16

1.3

-529

0.40

299

0.45

215

40.

583

221

4.61

06.

121

0.04

28.

514

–17

1616

142.

1-5

090.

438

126

0.48

821

30.

619

262

2.90

73.

859

0.03

95.

382

–27

2522

123.

3-5

170.

486

168

0.53

625

60.

668

323

1.82

62.

424

0.03

73.

393

–33

3127

105.

2-4

080.

553

243

0.60

331

30.

734

390

1.15

31.

530

0.03

52.

154

–44

4136

87.

6-4

090.

698

355

0.74

846

60.

921

591

0.70

80.

940

0.03

71.

339

–56

5248

612

.5-4

100.

794

533

0.84

466

91.

017

808

0.44

50.

590

0.03

50.

853

875

7064

421

-412

1.03

587

91.

085

1062

1.25

812

360.

300

0.39

90.

032

0.58

58

9992

852

34-4

141.

194

1120

1.24

413

451.

417

1677

0.18

40.

244

0.03

00.

369

613

112

211

31

43-4

151.

332

1602

1.38

219

091.

555

2144

0.14

70.

195

0.03

10.

302

615

314

313

11/

054

-416

1.46

519

071.

515

2180

1.75

024

340.

117

0.15

60.

030

0.24

86

176

164

152

2/0

70-4

171.

573

2535

1.62

326

651.

859

3050

0.09

30.

125

0.03

00.

203

620

118

817

53/

086

-418

1.75

432

061.

804

3578

2.04

040

030.

074

0.10

00.

029

0.16

84

234

218

202

4/0

109

-419

1.96

437

652.

014

4214

2.24

946

700.

058

0.08

00.

029

0.14

04

270

252

235

262

132

-420

2.20

546

252.

255

4795

2.49

056

100.

048

0.06

70.

029

0.12

23

315

294

267

313

159

-421

2.37

453

672.

424

5868

2.65

963

950.

040

0.05

60.

028

0.10

73

344

321

299

373

189

-422

2.49

564

622.

545

6853

2.83

875

760.

034

0.04

70.

028

0.09

53

387

361

334

444

227

-423

2.65

375

602.

703

7987

3.00

287

600.

028

0.04

10.

028

0.08

62

440

411

372

535

273

-424

2.98

992

843.

039

9762

3.33

810

570

0.02

40.

035

0.02

80.

077

246

344

341

864

632

6-4

263.

277

1057

13.

327

1094

63.

620

1184

00.

020

0.03

00.

029

0.07

11

553

516

470

Orde

ring

Gexo

l Oil

& G

as C

able

sEx

ampl

e:

• 4 c

ondu

ctor

pow

er c

able

• 0.6

/1kV

• #6

AWG

• bro

nze

arm

ored

& s

heat

hed

• with

gro

und

Amer

Cabl

e Ge

xol

Oil &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(from

cha

rts)

Arm

or R

equi

rem

ent

BS –

arm

ored

&sh

eath

edBl

ank

– no

arm

or

Grou

nd C

ondu

ctor

G

– w

ith g

roun

d Bl

ank

– no

gro

und

37–1

02–

410

BSG

Oil &

Gas

Cab

les

See

page

2 fo

r St

rand

ing

Prof

ile

Page 13: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

11

37-102

Five Conductor Power CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

JacketA black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compound meeting UL 1309/CSA 245 andIEEE 1580.

InsulationGEXOL® cross-linkedflame retardant polyolefin,meeting the requirementsfor Type P of IEEE 1580and Type X110 of UL 1309/CSA 245. Color code:Black-White-Red-Green-Orange

ConductorsSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA245 and IEEE 1580.

Armor (Optional)Basket weave wirearmor per IEEE 1580and UL 1309/CSA 245.Bronze standard. Tinned copper available by request.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 14: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

12

Arm

ored

and

Unar

mor

edAr

mor

ed (B

)Sh

eath

(BS)

Size

Nom

inal

Nom

inal

Nom

inal

AC R

esis

tanc

eIn

duct

ive

Volta

ge D

rop

AWG/

Part

No.

Diam

eter

Wei

ght

Diam

eter

Wei

ght

Diam

eter

Wei

ght

DC R

esis

tanc

e at

110°

C, 6

0 Hz

Reac

tanc

e11

0°C

Ampa

city

kcm

ilm

m2

37-1

02(in

ches

)(lb

s/M

Ft.)

(inch

es)

(lbs/

MFt

.)(in

ches

)(lb

s/M

Ft.)

25°C

(Ohm

s/10

00 ft

.)(O

hms/

1000

ft.)

(Ohm

s /1

000

ft.)

(Vol

ts/A

mp/

1000

ft.)

110°

C10

0°C

95°C

181.

0-5

580.

418

950.

468

165

0.59

921

47.

350

9.76

30.

044

13.5

5811

1011

161.

3-5

590.

437

110

0.48

718

90.

619

264

4.61

06.

121

0.04

28.

514

1413

1314

2.1

-510

0.47

914

90.

529

234

0.66

030

12.

907

3.85

90.

039

5.38

221

2018

123.

3-5

600.

550

196

0.60

026

60.

744

334

1.82

62.

424

0.03

73.

393

2725

2210

5.2

-561

0.60

429

60.

654

406

0.78

549

41.

153

1.53

00.

035

2.15

435

3329

87.

6-5

620.

765

453

0.81

556

90.

988

704

0.70

80.

940

0.03

71.

339

4542

386

12.5

-563

0.91

465

30.

964

813

1.13

797

30.

445

0.59

00.

035

0.85

360

5651

421

-565

1.13

710

731.

187

1292

1.36

014

810.

300

0.39

90.

032

0.58

579

7468

234

-566

1.31

513

611.

365

1637

1.53

818

560.

184

0.24

40.

030

0.36

910

598

901

43-5

671.

470

2130

1.52

021

921.

756

2482

0.14

70.

195

0.03

10.

302

122

114

105

1/0

54-5

681.

618

2550

1.66

827

461.

903

3108

0.11

70.

156

0.03

00.

248

140

131

122

2/0

70-5

691.

802

2954

1.85

233

012.

088

3734

0.09

30.

125

0.03

00.

203

161

150

140

4/0

109

-746

2.16

736

152.

217

3955

2.45

345

920.

058

0.08

00.

029

0.14

021

620

218

8

37-1

02

Five

Con

duct

or P

ower

Cab

leGe

xol®

Insu

late

dEx

trem

ely

Flex

ible

• 0.

6/1k

V • R

ated

110

°C

Man

ufac

ture

d by

Am

erCa

ble

Inco

rpor

ated

• 80

0-50

6-94

73 •

713-

896-

5800

• Fa

x: 7

13-8

49-9

009

1063

3 W

est L

ittle

Yor

k • B

ldg.

#1

• Sui

te #

100

• Hou

ston

, TX

7704

1 • w

ww

. am

erca

ble.

com

Flex

ible

Pow

er C

able

– F

ive

Cond

ucto

r

Cab

le d

iam

eter

s sh

own

as n

omin

al a

re s

ubje

ct t

o a

±5%

man

ufac

turin

g to

lera

nce

GEXO

L®is

a re

gist

ered

trad

emar

k of

Am

erCa

ble

Inco

rpor

ated

Orde

ring

Gexo

l Oil

& G

as C

able

sEx

ampl

e:

• 5 c

ondu

ctor

pow

er c

able

• 0.6

/1kV

• #2

AWG

• bro

nze

arm

ored

& s

heat

hed

Amer

Cabl

e Ge

xol

Oil &

Gas

Pre

fixSp

ecifi

c Ca

ble

Num

ber

(from

cha

rts)

Arm

or R

equi

rem

ent

BS –

arm

ored

&sh

eath

edBl

ank

– no

arm

or

37–1

02–

566

BS

Oil &

Gas

Cab

les

See

page

2 fo

r St

rand

ing

Prof

ile

Page 15: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

13

37-102

Multi-Conductor Control CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

InsulationGEXOL® cross-linked,flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.

JacketA black, arctic grade,flame retardant, oil,abrasion, chemicaland sunlight resistantthermosettingcompound meeting UL 1309/CSA 245 and IEEE 1580. Color code:IEEE 1580 Table 22

ConductorsSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Sheath (Optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistantthermosetting compound meeting UL 1309/CSA 245 and IEEE 1580. Color code: IEEE 1580 Table 22

Armor (Optional)Basket weave wirearmor per IEEE 1580and UL 1309/CSA 245.Bronze standard.Tinned copper available by request.

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1, and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 16: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

37-102

Multi-Conductor Control CableGexol® InsulatedExtremely Flexible • 0.6/1kV • Rated 110°C

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900914

GEXOL® is a registered trademark of AmerCable Incorporated

Armored andUnarmored Armored (B) Sheath (BS)

Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter Weight AmpacityAWG Conductors 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.) 110°C 100°C 95°C16 4 -529 0.402 99 0.452 154 0.583 227 17 16 1616 5 -559 0.437 110 0.487 189 0.619 264 14 13 1316 7 -505 0.475 155 0.525 255 0.656 330 12 11 1116 8 -503 0.531 164 0.581 265 0.712 340 12 11 1116 10 -504 0.631 206 0.681 366 0.812 445 9 8 1116 16 -546 0.719 299 0.769 465 0.942 602 9 8 1116 20 -687 0.794 360 0.844 560 1.017 724 9 8 1116 24 -525 0.923 462 0.973 718 1.146 809 8 7 1116 37 -526 1.048 658 1.098 819 1.271 989 6 6 816 44 -577 1.173 807 1.223 980 1.396 1175 6 6 816 60 -527 1.298 1053 1.348 1256 1.521 1496 6 6 816 91 -581 1.548 1595 1.598 1896 1.833 2181 6 6 814 4 -509 0.438 126 0.488 213 0.619 262 27 25 2214 5 -510 0.479 149 0.529 234 0.660 301 21 20 1814 6 -511 0.539 182 0.589 264 0.720 335 21 20 1814 7 -521 0.539 205 0.589 297 0.720 377 19 18 1514 10 -512 0.691 280 0.741 406 0.914 515 14 13 1514 12 -585 0.713 307 0.763 428 0.936 558 14 13 1514 14 -523 0.749 415 0.799 540 0.972 665 14 13 1514 20 -513 0.916 560 0.966 812 1.139 876 14 13 1514 24 -571 1.013 615 1.063 892 1.236 1132 12 11 1514 30 -573 1.071 780 1.121 965 1.294 1180 12 11 1314 37 -514 1.153 876 1.203 1135 1.376 1405 11 10 1314 44 -574 1.293 1087 1.343 1260 1.516 1477 10 9 1114 91 -582 1.775 2200 1.825 2465 2.060 2855 10 9 1112 4 -517 0.486 168 0.536 256 0.668 323 33 31 2712 5 -560 0.550 196 0.600 266 0.744 334 27 25 2212 6 -547 0.611 280 0.661 405 0.792 500 27 25 2212 10 -518 0.771 369 0.821 500 0.994 629 17 16 1912 20 -519 1.022 701 1.072 890 1.245 1055 17 16 1912 24 -572 1.133 861 1.183 1167 1.356 1468 15 14 1912 37 -520 1.293 1262 1.343 1467 1.516 1677 13 12 16

Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance

Flexible Control Cable – Multi-Conductor

Ordering Gexol Oil & Gas CablesExample:

• Multi-Conductor control cable• 0.6/1kV• #12 AWG• bronze armored & sheathed

AmerCable Gexol Oil & Gas Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

37–102 – 519 BS

Oil & Gas Cables

See page 2 for Stranding Profile

Page 17: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

15

GEXOL® is a registered trademark of AmerCable Incorporated

37-102

Shielded Pairs InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Pairs • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronzeor tinned copper.

ConductorSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Armor (Optional)Basket weave wirearmor per IEEE 1580and UL 1309/CSA245. Bronze standard.Tinned copperavailable by request.

InsulationGEXOL® cross-linkedflame retardant polyolefin,meeting the requirementsfor Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245.

JacketA black, arctic grade,flame retardant, oil,abrasion, chemical andsunlight resistantthermosetting compound meeting UL 1309/CSA 245 andIEEE 1580.

PairsEach pair is twisted with a bare tinned drain wire.Each pair is shielded withpolyester-backed aluminum foil tape toafford 100% coverage.Pair to pair isolation plusoverall shield is provided.Pair color code:Black-White

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compoundmeeting UL 1309/CSA 245and IEEE 1580.

Cable available with blue jacket or stripe to signify

intrinsically safe circuit.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 18: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

GEXOL® is a registered trademark of AmerCable Incorporated

37-102

Shielded Pairs InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Pairs • 0.6/1kV • Rated 110°C

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900916

Armored andUnarmored Armored (B) Sheath (BS)

Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter WeightAWG Pairs 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.)18 1 -601 0.336 63 0.386 123 0.486 17618 2 -602 0.551 131 0.601 204 0.732 33518 3 -603 0.581 163 0.631 265 0.762 34318 4 -604 0.630 195 0.680 317 0.801 41018 5 -605 0.685 243 0.735 395 0.900 51118 7 -606 0.742 340 0.792 457 0.957 57518 8 -607 0.800 388 0.850 521 1.015 75218 10 -608 0.976 495 1.026 699 1.199 87418 12 -609 1.011 581 1.061 780 1.234 98218 16 -645 1.121 748 1.171 833 1.344 118218 18 -641 1.181 824 1.231 1050 1.404 130018 24 -646 1.382 1069 1.432 1151 1.605 172016 1 -610 0.356 77 0.406 120 0.507 20316 2 -611 0.565 160 0.615 249 0.751 37716 3 -612 0.617 200 0.667 311 0.785 41016 4 -613 0.671 239 0.721 389 0.886 56916 5 -614 0.730 297 0.780 483 0.945 60916 7 -615 0.792 416 0.842 559 1.007 70316 8 -616 0.896 475 0.946 638 1.119 80316 10 -617 1.047 606 1.097 787 1.270 109816 12 -618 1.081 711 1.131 923 1.304 113816 16 -619 1.207 948 1.257 1231 1.422 151716 18 -626 1.265 1100 1.315 1260 1.488 157016 20 -688 1.327 1215 1.377 1476 1.552 189416 24 -699 1.482 1510 1.532 1625 1.767 206514 1 -620 0.386 97 0.436 151 0.537 19914 2 -621 0.621 202 0.671 315 0.802 48114 3 -622 0.658 251 0.708 391 0.881 51514 4 -623 0.721 301 0.771 469 0.944 63314 5 -624 0.791 374 0.841 608 1.013 78714 7 -625 0.905 524 0.955 704 1.128 88614 8 -630 0.979 498 1.029 803 1.202 101114 10 -627 1.148 747 1.198 1003 1.371 119614 12 -628 1.186 896 1.236 1203 1.409 1434

Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance

Flexible Instrumentation Cable – Individually Shielded Pairs

Ordering Gexol Oil & Gas CablesExample:

• Instrumentation cable• 0.6/1kV• #14 AWG• bronze armored & sheathed

AmerCable Gexol Oil & Gas Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

37–102 – 620 BS

VALUES:

#18 PairsCapacitance (nF/1000 feet) = 28Inductance (mH/1000) = 0.22Resistance (Ohms/1000 feet) = 7.21 (@ 20°C)

#16 PairsCapacitance (nF/1000 feet) = 32Inductance (mH/1000) = 0.20Resistance (Ohms/1000 feet) = 4.52 (@ 20°C)

#14 PairsCapacitance (nF/1000 feet) = 37Inductance (mH/1000) = 0.19Resistance (Ohms/1000 feet) = 2.85 (@ 20°C)

See page 2 for Stranding

Profile

Oil & Gas Cables

Page 19: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

17

37-102

Shielded Triads InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Triads • 0.6/1kV • Rated 110°C

www. amercable.com • e-mail: [email protected]

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS)

99-BT5905-X� Transport Canada 8700-20-2� Det Norske Veritas (DNV)

E-6669, E-6388, E-6390, E-6391� Lloyd’s Register of Shipping (LRS)

91/60333 (E6)� NVE 95/1696, FAL� UL Listed as Marine Shipboard Cable

(E111461) � United States Coast Guard

November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

ApplicationDesigned and constructed for the demandingenvironments of offshore drilling and petroleumfacilities located throughout the world.

Features� High strand count conductors make this

product much more flexible, easier to installand more resistant to vibration than Type MC,IEC spec or commercial cables.

� Gexol’s lower dielectric constant and higherinsulation resistance reduces electrical losses.

� Gexol’s excellent resistance to moistureproduces stable electrical properties throughoutthe life of the cable.

� In a fire condition, Gexol’s nonchlorinated flameretardant system produces less toxic and lesscorrosive gases.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1, and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronzeor tinned copper.

ConductorSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Armor (Optional)Basket weave wirearmor per IEEE 1580and UL 1309/CSA245. Bronze standard.Tinned copperavailable by request.

InsulationGEXOL® cross-linked, flame retardant polyolefin,meeting the requirementsfor Type P of IEEE 1580and Type X110 of UL 1309/CSA 245.

JacketA black, arctic grade,flame retardant, oil,abrasion, chemical andsunlight resistantthermosettingcompound meeting UL 1309/CSA 245 andIEEE 1580.

TriadsEach triad is twisted witha bare tinned drain wire.Each triad is shieldedwith polyester-backed aluminum foil tape toafford 100% coverage.Triad to triad isolationplus overall shieldingis provided.Triad color code:Black-White-Red

Sheath (Optional)A black, arctic grade,flame retardant, oil,abrasion, chemical and sunlight resistantthermosetting compound meeting UL 1309/CSA 245 and IEEE 1580. Cable available with

blue jacket or stripe to signify intrinsically safe circuit.

®

Oil & Gas Cables

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 20: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

37-102

Shielded Triads InstrumentationCable – Gexol® InsulatedExtremely Flexible • Individually Shielded Triads • 0.6/1kV • Rated 110°C

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900918

GEXOL® is a registered trademark of AmerCable Incorporated

#18 Triads

Capacitance – (nF/1000 feet) = 28

Inductance – (mH/1000) = 0.22

Resistance – (Ohms/1000 feet) = 7.21 (@ 20°C)

#16 TriadsCapacitance – (nF/1000 feet) = 32

Inductance – (mH/1000) = 0.20

Resistance – (Ohms/1000 feet) = 4.52 (@ 20°C)

VALUES:

Armored andUnarmored Armored (B) Sheath (BS)

Nominal Nominal NominalSize Number of Part No. Diameter Weight Diameter Weight Diameter WeightAWG Triads 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.)18 1 -647 0.354 75 0.404 144 0.504 19918 2 -681 0.649 183 0.699 290 0.872 38018 3 -648 0.688 190 0.738 305 0.911 39318 4 -682 0.755 281 0.805 408 0.978 55118 5 -649 0.871 286 0.921 419 1.094 56118 7 -650 0.947 409 0.997 565 1.170 72418 8 -683 1.026 515 1.076 680 1.249 87018 12 -640 1.244 766 1.294 965 1.467 119516 1 -668 0.376 86 0.426 155 0.558 21316 3 -669 0.735 218 0.785 338 0.958 46616 4 -698 0.807 410 0.857 530 1.030 70016 6 -676 1.012 630 1.062 750 1.235 95516 7 -670 1.012 710 1.062 835 1.235 105016 8 -677 1.090 729 1.140 876 1.330 1103

Cable diameters shown as nominal are subject to a ±5% manufacturing tolerance

Flexible Instrumentation Cable – Individually Shielded Triads

Ordering Gexol Oil & Gas CablesExample:

• Instrumentation cable• 0.6/1kV • #18 AWG• bronze armored & sheathed

AmerCable Gexol Oil & Gas Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

37–102 – 682 BS

Oil & Gas Cables

See page 2 for Stranding Profile

Page 21: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

Termination KitsAmerCable Systems offers pre-sized and pre-formed termination kit packages specificallyfor VFD cable constructions

37-102VFD

Type VFD Power CableGexol® InsulatedThree Conductor • 2kV • Rated 110°C

www. amercable.com • e-mail: [email protected] 19

ApplicationA flexible, braid and foil shielded, 2kV powercable specifically engineered for use in variablefrequency AC motor drive (VFD) applications.

Features� Specially engineered cable design produces

a longer cable life in VFD applications.� Overall braid and foil shield provides 100%

coverage containing VFD EMI emissions.� Symmetrical insulated ground conductors

reduce induced voltage imbalances and carry common mode noise back to the drive.

� High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable.

� Gexol’s lower dielectric constant (standardXLPEs, EPRs and other Type P insulationmaterials have higher dielectric constants)reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system.

� 2kV insulation thickness resists the repetitive 2x voltage spikes from 600V VFDs and reduces drive over current trip problems due to cable charging current.

� Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110.

� Highest ampacity ratings: ABS 100˚C, DNV95˚C, LRS 95˚C, Transport Canada 95˚C.

� Severe cold durability: exceeds CSA coldbend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1 and Zone 1 environments (armored and sheathed).

� Optional braid armor of bronze or tinned copper.

Insulation (2kV)Gexol® cross-linked flameretardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. Color: Gray with

printed phase I.D.(Black-White-Red)

JacketA black, arctic grade, flameretardant, oil, abrasion,chemical and sunlight resistant thermosetting compound meeting UL1309/CSA 245 and IEEE 1580.

Power Conductors (x3)Soft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

Ground Conductors (x3)Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.Gexol® insulation sized per UL 1277.Color: Green

Armor (Optional)Basket weave wirearmor per IEEE 1580and UL 1309/CSA 245.Bronze standard. Tinned copper available by request.

ShieldOverall tinned copperbraid plus aluminum/polyester tape providing100% coverage.

Sheath (Optional)A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580.

Ratings & Approvals (Other certifications pending)

� 110˚C Temperature Rating� American Bureau of Shipping (ABS): 99-BT5905-X� Transport Canada: 8700-20-2� Det Norske Veritas (DNV): E-6669, E-6388, E-6390,

E-6391� Lloyd’s Register of Shipping (LRS): 91/60333 (E6)� NVE: 95/1696, FAL� UL Listed as Marine Shipboard Cable: (E111461)� UL Listed as Type TC (E123629) available by request� United States Coast Guard: November 2, 1987 / 9304� CSA listed as Marine Shipboard Cable (82346)

Gexol insulation has lowcapacitance for superior

performance in VFD

®

Oil & Gas Cables

Page 22: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

37-102VFD

Type VFD Power CableGexol® InsulatedThree Conductor • 2kV • Rated 110°C

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900920

GEXOL® is a registered trademark of AmerCable Incorporated

SSiizzee NNoommiinnaall WWeeiigghhtt NNoommiinnaall WWeeiigghhtt NNoommiinnaall WWeeiigghhttAAWWGG// PPaarrtt NNoo.. DDiiaammeetteerr PPeerr PPaarrtt NNoo.. DDiiaammeetteerr PPeerr PPaarrtt NNoo.. DDiiaammeetteerr PPeerrkkccmmiill 3377--110022 IInncchheess** 11000000 FFtt.. 3377--110022 IInncchheess** 11000000 FFtt.. 3377--110022 IInncchheess** 11000000 FFtt.. SSiizzee ((AAWWGG)) 111100˚̊CC 110000˚̊CC 9955˚̊CC 9900˚̊CC 7755˚̊CC

14 -508VFD 0.540 194 -508BVFD 0.590 281 -508BSVFD 0.725 356 18 27 25 22 - 18

12 -516VFD 0.590 224 -516BVFD 0.646 321 -516BSVFD 0.772 401 18 33 31 27 - 24

10 -308VFD 0.633 308 -308BVFD 0.694 412 -308BSVFD 0.820 497 14 44 41 36 - 33

8 -309VFD 0.764 441 -309BVFD 0.820 565 -309BSVFD 0.988 702 14 56 52 48 - 43

6 -310VFD 0.865 570 -310BVFD 0.925 708 -310BSVFD 1.090 865 12 75 70 64 93 58

4 -312VFD 1.072 886 -312BVFD 1.125 1061 -312BSVFD 1.295 1243 12 99 92 85 122 79

2 -314VFD 1.215 1421 -314BVFD 1.271 1618 -314BSVFD 1.440 1822 10 131 122 113 159 105

1 -315VFD 1.340 1517 -315BVFD 1.395 1743 -315BSVFD 1.560 1966 10 153 143 131 184 121

1/0 -316VFD 1.443 1803 -316BVFD 1.493 2027 -316BSVFD 1.666 2327 10 176 164 152 211 145

2/0 -317VFD 1.572 2153 -317BVFD 1.622 2399 -317BSVFD 1.854 2840 10 201 188 175 243 166

4/0 -319VFD 2.053 3463 -319BVFD 2.103 3785 -319BSVFD 2.335 4347 8 270 252 235 321 223

262 -320VFD 2.193 4175 -320BVFD 2.243 4522 -320BSVFD 2.475 5120 6 315 294 267 365 254

313 -321VFD 2.370 4727 -321BVFD 2.420 5104 -321BSVFD 2.652 5747 6 344 321 299 408 287

373 -322VFD 2.501 5415 -322BVFD 2.551 5809 -322BSVFD 2.845 6674 6 387 361 334 451 315

444 -323VFD 2.670 6707 -323BVFD 2.721 7141 -323BSVFD 3.014 8059 6 440 411 372 499 350

535 -324VFD 2.972 7483 -324BVFD 3.022 7966 -324BSVFD 3.316 8981 6 498 443 418 - 390

646 -326VFD 3.164 8916 -326BVFD 3.214 9428 -326BSVFD 3.508 10504 4 553 516 470 - 431

777 -327VFD 3.388 10395 -327BVFD 3.438 10940 -327BSVFD 3.732 12088 4 602 562 529 473

*Cable diameters are subject to a +/- 5% manufacturing tolerance

GGrreeeenn IInnssuullaatteeddGGrroouunnddiinngg

CCoonndduuccttoorr ((xx33))

andhas a

low capacitance for superior performance in

VFD applications!

Gexolis

flexible

110°C RatingsBased on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For thoseinstances where cable must be double banked, the 110°C ampacities should be multiplied by 0.8.

100°C Ratings Based on IEEE Std. 45 with a 45°C ambient and arranged in a single bank per hanger. For thoseinstances where cable must be double banked, the 100°C ampacities should be multiplied by 0.8.

95°C Ratings Based on 4-3-4/Table 10 of the 2001 ABS MODU rules and a 45°C ambient.

90°C Ratings Based on ICEA S-75-381 Table H-1 for a single isolated cable in air with a 40°C ambient. Thisampacity is typically used for mining and other portable applications.

75°C Ratings Based on Table B.310.1 of the 2005 NEC for cables in raceway and a 30°C ambient.

VFD Cable Ampacity Ratings

Unarmored ArmoredArmored &

Sheathed (BS)

Ampacity

Oil & Gas Cables

See page 2 for Stranding Profile

Page 23: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

37-105

Type MMV Medium Power CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

www. amercable.com • e-mail: [email protected]

ApplicationsAmerCable’s Type MMV marine mediumvoltage cables are for use aboard commercial ships, mobile offshoredrilling units (MODUs), and fixed orfloating offshore facilities.

Features� These cables utilize flexible

stranded conductors, braided shieldsand a braided armor (when armored)which make them very suitable forapplications involving repeated flexingand high vibration.

� These cables have a small minimumbending radius (6xOD for unarmoredcables and 8xOD for armored cables) for easy installation.

� Optional uninsulated groundingconductors sized per UL 1072.

� The increased flexibility of this cableallows for termination of one end and coiling on multiple module offshore platforms. Then coiling andterminating other end when modulesare mated at sea thereby reducinginstallation time.

� Passes IEC 332-3 Category A and IEEE 1202 flame tests.

Conductor ShieldA combination of semi-conducting tape andextruded thermosetting semi-conductingmaterial meeting UL 1309, IEEE 1580, ICEA S-68-516 and UL1072.

Armor (optional)(Optional) 0.0126" bronze braid providing 88%minimum coverage meeting UL 1309 and IEEE Std. 45-1998.

JacketA black, arctic grade, flame retardant, oil, abrasion,chemical and sunlight resistant thermosetting compound meeting UL 1309, IEEE 1580, ICEA S-68-516 and UL 1072. Colored jackets for signifyingdifferent voltage levels are also available on specialrequest (ie. yellow = 5kV, orange = 8kV and red = 15kV).

Sheath (optional)A black, arctic grade, flame retardant, oil, abrasion,chemical, and sunlight resistant thermosetting compound meeting UL 1309, IEEE 1580, ICEA S-68-516 and UL 1072. Colored jackets forsignifying different voltage levels is also availableon special request (ie. yellow = 5kV, orange = 8kv and red = 15kV).

Metallic ShieldComposite shieldconsisting of 0.0126"tinned copper braided with nylonproviding 60% copper Shieldedcoverage meetingUL 1309, IEEE Std.1580, ICEA S-68-516 and UL 1072.The nylon is coloredfor easy phase identification (threeconductor = black,blue, red) withoutthe need to removethe shield to find anunderlying coloredtape.

Insulation ShieldSemi-conducting tape, with overlap, for fastand easy termination meeting UL 1309, IEEE 1580, ICEA S-68-516 and UL 1072.

ConductorsSoft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

InsulationExtruded thermosetting90°C Ethylene PropyleneRubber (EPR), meetingUL 1309 (Type E), IEEE 1580 (Type E),ICEA S-68-516 and UL 1072.

Grounding Conductor (optional)One uninsulated soft annealed flexible strandedtinned copper conductor per ASTM B 33 andsized according to Table 21.1 of UL 1072.

Ratings & Approvals� UL Listed as Marine Shipboard Cable (E111461)� American Bureau of Shipping (ABS)� Det Norske Veritas (DNV) Pending� Lloyd’s Register of Shipping (LRS) Pending� 90˚C Temperature Rating� Voltage Rating – 5kV to 15kV

(25kV available on request)

Termination KitsAmerCable recommendsRaychem’s HVT seriesterminations for single conductorconstructions and HVT-M seriesterminations for multi-conductorconstructions.

®

Oil & Gas Cables

21

HawkeGland Types Unarmored Armored & Sheathed

Industrial & Safe Area (IP68) 121 153-XIncreased Safety 501/421 501/453/U“EExe”Explosion Proof 710 753

Class I, Div. 2 Class I, Div. 1Class I, Zone 2 Class I, Zone 1 & 2

Flameproof 501/421 501/453/U“EExd” Zone 1 & 2 (2 liter or < enclosures)

ICG 653/U(2 liter or > enclosures)

Zone 1 & 2

Page 24: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance

AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

86421

1/02/03/04/0

262313373444535646777

1111

7.612.5

213443547086

109132159189227273326394562

-101-102-103-104-105-106-107-108-109-110-111-112-113-114-115-116-117

0.5640.6040.6860.7500.7900.8770.9370.9801.0421.1211.1871.2521.3271.4081.4961.5991.883

204252344449528659787910

108612721467169219682294267231544414

1.2820.8220.5660.3610.2960.2450.2020.2780.1410.1220.1080.0950.0860.0770.0700.0650.054

0.0540.0500.0440.0410.0400.0390.0380.0370.0350.0340.0330.0320.0320.0310.0300.0300.029

0.7510.8360.9180.9811.0641.1081.1681.2121.2741.3531.4191.4841.5591.7061.7931.8812.169

401502622748894

100411601298149617081926217424762949336138595255

0.0610.0580.0510.0470.0470.0450.0430.0420.0400.0380.0370.0360.0350.0350.0340.0330.033

1.2880.8300.5730.3670.3030.2500.2070.1730.1460.1270.1120.0990.0900.0820.0750.0690.057

80107141186214247285328381435486544606682767865

1084

6992

121159184212244281325371413460510570635709853

6891

120158182210242279324370413462515580652735921

0.6940.4360.2860.1750.1400.1110.0890.0700.0560.0460.0380.0320.0270.0220.0190.0150.011

0.8850.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.0330.0280.0250.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 5kV, 100/133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance

AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

6421

1/02/03/04/0

262313373444535646777

1111

12.5213443547086

109132159189227273326394562

-118-119-120-121-122-123-124-125-126-127-128-129-130-131-132-133

0.6560.7380.8010.8840.9290.9891.0321.0941.1731.2391.3041.3791.4601.5481.6511.935

283378486604702835956

113513241522175020292359274131864498

0.8240.5670.3620.2980.2460.2030.1690.1420.1230.1090.0960.0870.0780.0710.0660.055

0.0520.0460.0430.0420.0410.0390.0380.0360.0350.0340.0330.0330.0320.0310.0300.030

0.8880.9701.0331.1081.1601.2201.2641.3261.4051.4711.5361.6031.7461.8331.9492.233

549673806942

107212261363156317791999225025383012342839445388

0.0590.0520.0480.0470.0460.0440.0430.0410.0390.0380.0370.0360.0360.0350.0340.033

0.8310.5740.3680.3040.2510.2080.1740.1470.1280.1130.1000.0910.0820.0750.0700.058

107141186214247285328381435486544606682767865

1084

92121159184212244281325371413460510570635709853

91120158182210242279324370413462515580652735921

0.4360.2860.1750.1400.1110.0890.0700.0560.0460.0380.0320.0270.0220.0190.0150.011

0.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.0330.0280.0250.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 8kV, 100% Insulation LevelArmored &

Sheathed (BS) Ampacity

®

Oil & Gas Cables

22 Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-9009

See page 29 for MMV

Stranding Profile

Page 25: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

www. amercable.com • e-mail: [email protected] 23

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance

AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

6421

1/02/03/04/0

262313373444535646777

1111

12.5213443547086

109132159189227273326394562

-134-135-136-137-138-139-140-141-142-143-144-145-146-147-148-149

0.7100.7920.8980.9380.9831.0431.0861.1481.2271.2931.3581.4331.4601.6021.7671.989

317417565648751884

1007118913811584181320952359281433764587

0.8260.5690.3650.3000.2470.2040.1710.1430.1240.1100.0970.0880.0780.0720.0670.055

0.0540.0470.0450.0440.0420.0400.0390.0380.0360.0350.0340.0330.0320.0320.0320.031

0.9421.0161.1291.1701.2141.2741.3181.3801.4591.5241.5821.7191.7581.8882.0652.275

603725916

1022114012931432163518542081231827343034352941815470

0.0600.0530.0500.0490.0470.0450.0440.0420.0400.0390.0380.0380.0360.0360.0360.034

0.8320.5750.3700.3050.2520.2090.1750.1480.1290.1140.1010.0930.0830.0760.0710.058

107141186214247285328381435486544606682767865

1084

92121159184212244281325371413460510570635709853

91120158182210242279324370413462515580652735921

0.4360.2860.1750.1400.1110.0890.0700.0560.0460.0380.0320.0270.0220.0190.0150.011

0.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.0330.0280.0250.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 8kV, 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance

AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

21

1/02/03/04/0

262313373444535646777

1111

3443547086

109132159189227273326394562

-150-151-152-153-154-155-156-157-158-159-160-161-162-163

1.0501.0881.1331.1911.2361.2981.3971.4631.5281.6031.7421.8301.9652.187

692778883

10241154134315681778201523132762316537294930

0.3690.3030.2510.2080.1740.1460.1280.1130.1000.0910.0820.0750.0700.057

0.0490.0470.0450.0440.0420.0400.0390.0380.0370.0360.0360.0350.0340.033

1.2691.3081.3521.4101.4561.5181.6161.7441.8091.8842.0242.1122.2462.468

10881186130114621608181720772422268530143520396045785870

0.0530.0510.0490.0470.0460.0440.0420.0420.0410.0400.0390.0380.0370.036

0.3730.3080.2550.2120.1780.1500.1310.1170.1040.0950.0860.0790.0730.060

186214247284327378431481536598672754848

1061

164189217250288332377418464514574638709857

158182210241278321366409456508571641721902

0.1750.1400.1110.0890.0700.0560.0460.0380.0320.0270.0220.0190.0150.011

0.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.0330.0280.0250.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 15kV, 100% Insulation LevelArmored &

Sheathed (BS) Ampacity

Ordering Type MMV Medium Voltage CablesExample:

• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed

AmerCable TypeMMV Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

Ground ConductorG – with groundBlank – no ground

37–105 – 319 BS G

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

®

Oil & Gas Cables

See page 29 for MMV

Stranding Profile

Page 26: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

Inductive Voltage Inductive Voltage Single DC ACSize Part Nominal Weight Reactance Drop Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance

AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 25°C at 90°C, 60 Hzkcmil mm2 37-105 (inches) 1000 ft.) 1000 ft.) 1000 ft.) (inches) 1000 ft.) 1000 ft.) 1000 ft.) (amps) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.)

21

1/02/03/04/0

262313373444535646777

1111

3443547086

109132159189227273326394562

-164-165-166-167-168-169-170-171-172-173-174-175-176-177

1.1321.1701.2151.2731.3381.4001.4791.5451.6101.7471.8241.9442.0472.269

771863970

11121267146116701884213225412889335038705083

0.3700.3050.2520.2090.1760.1480.1290.1140.1010.0930.0840.0770.0710.058

0.0500.0490.0470.0450.0440.0420.0400.0390.0380.0380.0370.0360.0350.034

1.3521.3901.4341.4921.5581.6201.7611.8271.8922.0292.1062.2262.3292.551

11941299141615781756197123202561283633013680419147536057

0.0550.0530.0510.0490.0470.0460.0440.0430.0420.0410.0400.0390.0380.036

0.3750.3090.2560.2130.1790.1510.1330.1180.1050.0960.0870.0800.0740.061

186214247284327378431481536598672754848

1061

164189217250288332377418464514574638709857

158182210241278321366409456508571641721902

0.1750.1400.1110.0890.0700.0560.0460.0380.0320.0270.0220.0190.0150.011

0.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.0330.0280.0250.017

Unarmored

Single Conductor Type MMV Marine Medium Voltage – 15kV, 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional

AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

86421

1/02/03/04/0

262313373444535646777

7.612.5

213443547086

109132159189227273326394

-301-302-303-304-305-306-307-308-309-310-311-312-313-314-315-316

1.1371.2261.4021.5381.6261.7831.9132.0072.1402.3102.4532.5892.8182.9743.1643.385

781955

1307169019742423288433153937461953196107728084639814

11526

12181424182423722692323237494220489956546549740286849964

1140713226

1.3691.4571.6251.8241.9112.0812.2102.3052.4382.6082.7963.0003.1613.3173.5073.729

6688

116152175201232266306348386429455528584647

567599

129149171197226260296328365387449496550

0.7080.4450.3000.1840.1470.1170.0930.0740.0580.0480.0400.0340.0280.0240.0200.016

0.8850.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.0330.0280.025

0.0480.0440.0390.0360.0350.0340.0330.0320.0310.0300.0290.0290.0280.0280.0270.027

1.2750.8150.5600.3560.2910.2390.1960.1630.1360.1180.1040.0920.0830.0740.0670.062

866644433322111

1/0

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 5kV, 100/133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900924

®

Oil & Gas Cables

See page 29 for MMV

Stranding Profile

v2.08.1

Page 27: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

www. amercable.com • e-mail: [email protected] 25

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional

AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

6421

1/02/03/04/0

262313373444535646

12.5213443547086

109132159189227273326

-332-333-334-335-336-337-338-339-340-341-342-343-344-345

1.4541.6301.8291.9162.0122.1412.2362.3692.5392.6802.8853.0363.2103.400

1249163921622467283833273763441751335870688479599167

10554

189623592964330637174259473454436422722783409491

1078212261

1.7401.9162.1142.2022.2972.4272.5212.6542.8883.0313.2353.3803.5523.742

88116152175201232266306348386429455528584

7599

129149171197226260296328365387449496

0.4450.3000.1840.1470.1170.0930.0740.0580.0480.0400.0340.0280.0240.020

0.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.0330.028

0.0480.0430.0400.0380.0370.0360.0350.0330.0320.0320.0310.0300.0300.029

0.8200.5640.3590.2940.2420.1990.1660.1390.1210.1060.0940.0850.0760.069

66644433322111

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 8kV, 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional

AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

6421

1/02/03/04/0

262313373444535646777

12.5213443547086

109132159189227273326394

-317-318-319-320-321-322-323-324-325-326-327-328-329-330-331

1.3381.5141.6501.8001.8952.0252.1192.2522.4222.5652.7042.9303.0963.2673.512

1094146219702263261731003531416248645581639275828806

1013711959

158921342725305434543989445851405913688477609059

103661178013708

1.5611.7991.9982.0852.1812.3102.4042.5372.7072.9143.0543.2803.4393.6113.855

88116152175201232266306348386429455528584647

7599

129149171197226260296328365387449496550

0.4450.3000.1840.1470.1170.0930.0740.0580.0480.0400.0340.0280.0240.0200.016

0.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.0330.0280.025

0.0460.0410.0380.0370.0360.0340.0330.0320.0310.0300.0300.0290.0290.0280.028

0.8180.5620.3570.2930.2410.1980.1650.1380.1190.1050.0930.0840.0750.0680.063

66644433322111

1/0

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 8kV, 100% Insulation LevelArmored &

Sheathed (BS) Ampacity

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

®

Oil & Gas Cables

Ordering Type MMV Medium Voltage CablesExample:

• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed

AmerCable TypeMMV Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

Ground ConductorG – with groundBlank – no ground

37–105 – 319 BS G

See page 29 for MMV

Stranding Profile

Page 28: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional

AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

21

1/02/03/04/0

262313373444535

3443547086

109132159189227273

-346-347-348-349-350-351-352-353-354-355-356

2.1572.2392.3352.4612.5592.6912.7492.8813.0213.1833.357

27593073346639914466515057496483733183809599

3697404544775242576465137348818488569983

11285

2.4432.5242.6202.8102.9103.0413.1523.2873.3653.5273.701

156178205234269309352389432456528

133151174199229263299331367388449

0.1840.1470.1170.0930.0740.0580.0480.0400.0340.0280.024

0.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.033

0.0420.0400.0390.0370.0360.0350.0340.0330.0320.0310.031

0.3610.2960.2440.2010.1680.1410.1220.1070.0950.0860.077

64443332211

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 15kV, 100% Insulation LevelArmored &

Sheathed (BS) Ampacity

Single InductiveSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional

AWG/ Part No. Diameter (Lbs./ Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Groundingkcmil mm2 37-105 (inches) 1000 ft.) (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Conductor

21

1/02/03/04/0

262313373444535

3443547086

109132159189227273

-357-358-359-360-361-362-363-364-365-366-367

2.3342.4162.5122.6372.8422.9762.9893.0913.2043.3473.521

3125347038744411520659306412699078978879

10144

413745155150574866407430783185299510

1056011910

2.6192.7012.8612.9873.1923.3253.3403.3943.5483.6903.865

156178205234269309352389432456528

133151174199229263299331367388449

0.1840.1470.1170.0930.0740.0580.0480.0400.0340.0280.024

0.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.033

0.0440.0430.0410.0390.0380.0370.0350.0340.0340.0330.033

0.3640.2990.2460.2030.1700.1420.1240.1090.0970.0880.079

64443332211

Unarmored

Three Conductor Type MMV Marine Medium Voltage – 15kV, 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-900926

Ordering Type MMV Medium Voltage CablesExample:

• 3 conductor power cable• 8kV 100%• #2 AWG• ground• bronze armored & sheathed

AmerCable TypeMMV Prefix

Specific Cable Number(from charts)

Armor RequirementBS – armored &

sheathedBlank – no armor

Ground ConductorG – with groundBlank – no ground

37–105 – 319 BS G

®

Oil & Gas Cables

See page 29 for MMV

Stranding Profile

v2.08.1

Page 29: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

www. amercable.com • e-mail: [email protected] 27

®

Oil & Gas Cables

v2.08.1

37-105VFD

Type MMV-VFDPower CableThree Conductor: 8kV –15kV • 133% Insulation Level • Rated 90°C

ApplicationsA flexible, braid and foil shielded,power cable specifically engineered for use in medium voltage variable frequency AC drive (VFD) applications.

Features� Flexible stranded conductors,

braided shields and a braided armor(when armored). Suitable for applications involving repeated flexing and high vibration.

� Small minimum bending radius (6xOD for unarmored cables and 8xODfor armored cables) for easy installation.

� Insulation resists the repetitive 3x voltage spikes from VFDs and reducesdrive over current trip problems due to cable charging current.

� Overall braid and foil shield provides100% coverage containing VFD EMI emissions.

� Symmetrical insulated ground conductors reduce induced voltageimbalances and carry common mode noise back to the drive.

� High strand count conductors andbraid shield design is much more flexible, easier to install and moreresistant to vibration than Type MC cable.

� Severe cold durability: exceeds CSA cold bend/cold impact (-40˚C/-35˚C).

� Flame retardant: IEC 332-3 Category A and IEEE 1202.

� Suitable for use in Class I, Division 1and Zone 1 environments (armoredand sheathed).

Conductor ShieldA combination of semi-conducting tape andextruded thermosetting semi-conductingmaterial meeting UL 1309, IEEE 1580, ICEA S-68-516 and UL1072.

Armor (optional)Basket weave wire armor per IEEE 1580 and UL 1309/CSA 245. Bronze standard. Tinned copper available by request.

JacketA black, arctic grade, flame retardant, oil, abrasion,chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245, IEEE 1580,and UL 1072. Colored jackets for signifying differentvoltage levels are also available on special request(orange = 8kV and red = 15kV).

Sheath (optional)A black, arctic grade, flame retardant, oil, abrasion,chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245, IEEE 1580,and UL 1072. Colored jackets for signifying differentvoltage levels are also available on special request(orange = 8kV and red = 15kV).

Insulation ShieldComposite shieldconsisting of 0.0126"tinned copper braidedwith nylon providing60% copper Shieldedcoverage meeting UL1309, IEEE Std. 1580,ICEA S-68-516 and UL1072. The nylon iscolored for easy phase identification (threeconductor = black, blue,red) without the need toremove the shield to findan underlying coloredtape.

Insulation ShieldSemi-conducting layer meeting UL 1309, IEEE 1580, ICEA S-68-516 and UL 1072.

EMI ShieldOverall tinned copperbraid plus aluminum/polyester tape providing100% coverage

Conductors (3)Soft annealed flexiblestranded tinned copperper IEEE 1580 Table 11.

InsulationExtruded thermosetting90°C Ethylene PropyleneRubber (EPR), meetingUL 1309 (Type E), IEEE 1580 (Type E),ICEA S-68-516 and UL 1072.

Symmetrical InsulatedGrounding Conductors (3)Soft annealed flexible stranded tinned copperconductor per IEEE 1580 Table 11. Gexol Insulationsized per Table 23.2 of UL1072. Color: Green

Ratings & Approvals� UL Listed as Marine Shipboard

Cable (E111461)� American Bureau of Shipping (ABS)� Det Norske Veritas (DNV) Pending� Lloyd’s Register of Shipping (LRS)

Pending� 90˚C Temperature Rating� Voltage Rating – 8kV to 15kV

(25kV available on request)

Termination Kits

AmerCableSystems offers

pre-sized and pre-formed termination kit

packages specifically for

VFD cable constructions

Low smoke halogen-free jacket available on request.

Page 30: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

Manufactured by AmerCable, Incorporated • (870) 862-4919 • (800) 643-1516 • Fax (870) 862-961328

37-105VFD

Type MMV-VFDPower CableThree Conductor: 8kV –15kV • 133% Insulation Level • Rated 90°C

Single Inductive Voltage Green InsulatedSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding

AWG/ Part No. Diameter (Lbs./ Part No. Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Conductor (3x)kcmil mm2 37-105 (inches) 1000 ft.) 37-105 (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Size (AWG)

6421

1/02/03/04/0262313373444535

12.5213443547086

109132159189227273

-332VFD-333VFD-334VFD-335VFD-336VFD-337VFD-338VFD-339VFD-340VFD-341VFD-342VFD-343VFD-344VFD

-332BSVFD-333BSVFD-334BSVFD-335BSVFD-336BSVFD-337BSVFD-338BSVFD-339BSVFD-340BSVFD-341BSVFD-342BSVFD-343BSVFD-344BSVFD

1.5411.7281.9392.0312.1332.2692.3702.5112.6912.8413.0583.2183.403

1349177023352664306535934064477055446340743585969900

20482548320135704014460051135878693678059007

102501164

1.8792.0692.2832.3782.4812.6212.7232.8663.1193.2733.4943.6503.836

88116152175201232266306348386429455528

7599

129149171197226260296328365387449

0.4450.3000.1840.1470.1170.0930.0740.0580.0480.0400.0340.0280.024

0.5560.3760.2300.1840.1470.1170.0940.0750.0630.0530.0450.0390.033

0.0480.0430.0400.0380.0370.0360.0350.0330.0320.0320.0310.0300.030

0.8200.5640.3590.2940.2420.1990.1660.1390.1210.1060.0940.0850.076

1010108886666444

Unarmored

Three Conductor Type MMV-VFD Marine Medium Voltage – 8kV • 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Single Inductive Voltage Green InsulatedSize Nominal Weight Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding

AWG/ Part No. Diameter (Lbs./ Part No. Diameter (Lbs./ Air in Trays at 25°C at 90°C, 60Hz (ohms/ (Volts per amp Conductor (3x)kcmil mm2 37-105 (inches) 1000 ft.) 37-105 (inches) 1000 ft.) (amps) (amps) (ohms/1000 ft.) (ohms/1000 ft.) 1000 ft.) per 1000 ft.) Size (AWG)

21

1/02/03/04/0262313373444

3443547086

109132159189227

-357VFD-358VFD-359VFD-360VFD-361VFD-362VFD-363VFD-364VFD-365VFD-366VFD

-357BSVFD-358BSVFD-359BSVFD-360BSVFD-361BSVFD-362BSVFD-363BSVFD-364BSVFD-365BSVFD-366BSVFD

2.4742.5612.6632.7953.0133.1553.1683.2763.3963.548

3375374841844764562264046925754985299589

44684876556262087171802484579211

1027111405

2.8292.9173.0903.2263.4473.5913.6073.6663.8323.985

156178205234269309352389432456

133151174199229263299331367388

0.1840.1470.1170.0930.0740.0580.0480.0400.0340.028

0.2300.1840.1470.1170.0940.0750.0630.0530.0450.039

0.0440.0430.041

0.0390.038

0.0370.0350.0340.0340.033

0.3640.2990.2460.2030.1700.1420.1240.1090.0970.08

10888666644

Unarmored

Three Conductor Type MMV-VFD Marine Medium Voltage – 15kV • 133% Insulation LevelArmored &

Sheathed (BS) Ampacity

Ordering Type MMV-VFD Medium Voltage CablesExample:

• 3 conductor MMV-VFD power cable• 15kV• #2 AWG• bronze armored & sheathed

AmerCable Type MMV-VFD Prefix

Specific CableNumber (from charts)

37–105 – 357BSVFD

Ordering Type MMV-VFD Medium Voltage CablesExample:

• 3 conductor MMV-VFD power cable• 8kV• #6 AWG• Unarmored

AmerCable Type MMV-VFD Prefix

Specific CableNumber (from charts)

37–105 – 332VFD

®

Oil & Gas Cables

Page 31: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

www. amercable.com • e-mail: [email protected] 29

Ampacities are based on API RP 14F (June 1999)Table 4 or 5 for single conductor cables and Table3 for multi-conductor cables. The notes to thesetables are also applicable. Ampacities are alsobased on a 90°C conductor temperature and a45°C ambient temperature.Inductive reactance and voltage drop values are based on a 90°C conductor temperature and 60 Hz operation. Values for single conductor cables are based on a symmetrical triangular configuration.Please consult AmerCable on values for other configurations.

MMV Ampacities & Electrical Data

Individual Closest Equivalent UninsulatedSize Number Strand Dia. IEEE 45 Metric Size Conductor

AWG/kcmil of Strands (inches) Std. Size (mm2) Dia. (inches)

86421

1/02/03/04/0

262313373444535646777

1111

3761

133133209266342418532646777925

11101332159119242745

0.0201 0.0201 0.0177 0.0223 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201 0.0201

1626416683

106133168212262313373444535646777

1111

7.57 12.49 21.11 33.51 42.79 54.45 70.01 85.57

108.91 132.25 159.06 189.36 227.23 272.68 325.70 393.87 561.94

0.136 0.175 0.258 0.324 0.361 0.407 0.461 0.510 0.575 0.654 0.720 0.785 0.860 0.941 1.029 1.132 1.354

MMV Bend RadiusUnarmored Armored Armored & Sheathed

IEEE 45 6X Diameter 8X Diameter 8X Diameter

IEC 92 <1" (25mm) 6X Diameter 8X Diameter4 x Diameter>1" (25mm)6X Diameter

Transport <1" (25mm) 6X Diameter 6X DiameterCanada 4X Diameter

>1" (25mm)6X Diameter

37-105

Type MMV Medium Voltage CableSingle Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°CMulti-Conductor: 5kV – 15kV, 100% & 133% Insulation Levels. Rated 90°C

MMV Stranding Profile

®

Oil & Gas Cables

Page 32: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

Designed to deliver outstanding performance in the harshest operating conditions – specifically in high temperature Ester Based drilling muds.

Designed to deliver outstanding performance in the harshest operating conditions – specifically in high temperature Ester Based drilling muds.

30

Ester Based Mud ResistantJacketed Cables110°C • UL Marine Shipboard Cable

A swollen orsplit cable

jacket due to drillingmud exposure

is a productivity

killer.

AmerCableoffers three

levels of mudresistance tomatch youroperating

conditions:

Standard, Advanced and

Ester Based Mud Resistant

Page 33: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

www. amercable.com • e-mail: [email protected] 31

1 All results representative of finished cables (6 3/C, 14 7/C and 18 7 PR). Test data on file at AmerCable

Aging Requirements 90°C Rated Jacket121±1°C Air Oven 240 Hours

Oil ExposureResistanceAfter Oil Immersion at121±1°C 18 Hours

Jacket Type Type N Type N Mud Resistant Jacket

Tensile Strength, Min, PSI 1800 1800 Pass

300 300 Pass

20 20 Pass

Elongation at Rupture, Min, %

Set, Max, %

Tensile Strength,Minimum

900 psi 900 psi Pass

50%Actual

50%Actual

Pass

80 80 Pass

60 60 Pass

100 130 Pass

Elongation at Rupture, %

Tensile Strength, % Retentionof Unaged, Min

Elongation at Rupture, %Retention of Unaged, Min

Mechanical WaterAbsorption mg / in2

Weatherometer TestNo

RequirementPass PassPer UL 1581

Tear NoRequirement

35 Passlb/in Thickness, Min

FT4/IEEE 1202 FlameExposure (UL-1685)

Pass Pass Pass–

IEC 332-3 FlameExposure

NoRequirement

No Requirement Pass–

Table ISpecifications UL-1309

Table 4IEEE 1580Table 5-7

AmerCable TestingProgram1

World Class Mud ResistantJacket

PhysicalRequirements –Unaged

When standard mud resistance isn’t enough, AmerCable has aWorld Class Mud Resistant cable jacket designed to deliveroutstanding performance in the harshest operating conditions.Designed specifically for exposure to high temperature ESTERBASED drilling muds, this cable meets all the performancerequirements of industry standards UL 1309 and IEEE 1580for Type N jackets. When tested for prolonged exposure to themost aggressive ester based drilling muds, it easily passes the mud resistance requirements of NEK 606.

AmerCable’s ester based mud resistant cables were also testedagainst the requirements of UL 1309 and IEEE 1580 and theresults are shown in Table I.1 This product easily passed allthe requirements. Table II shows the results of this cablewhen aged in Baroid Petrofree® (Ester Based) drilling mud perNEK 606. All aging requirements were met. Additional testingdone on these cables show the jacket to pass cold impact at -20°C and cold bend at -40°C.

Table II

MUD Resistant –NEK 606

Note: Tested forChanges in Each ListedRequirement

70°C, 56 Days

Elongation at Break ±25% Baroid Petrofree® (Ester Based) Pass

Tensile Strength ±25% Baroid Petrofree® (Ester Based) Pass

Volume Swelling Max 20% Baroid Petrofree® (Ester Based) Pass

Weight Increase Max 15% Baroid Petrofree® (Ester Based)

Baroid Petrofree® (Ester Based)

Pass

Oxygen Index Min 25% Pass

Requirements Mud Type Results

Ester Based Mud ResistantJacketed Cables110°C • UL Marine Shipboard Cable

®

Oil & Gas Cables

v2.08.1

Page 34: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

The Assembly Application ProfessionalsThe Assembly Application Professionals

CableASSEMBLIESCableASSEMBLIES

Precision Engineered

Turn-key cable assembly solutions for hazardous

and industrial environments

Constructions:� 300V – 15kV AC� DC Power� Composite Power

& Control� Instrumentation� Thermocouple� Fiber Optic� Electro-Optic

Applications:� Service Loops� Driller’s Console� Mud Pump Controls� 15kV Bridle Assembly� Tender-to-Platform Bridle� Ship-to-Shore Power� Portable Power Generation� Zone 1 (EX) Rated

Cable Assemblies

32

Page 35: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

(800) 506-9473

[email protected]

Cable Assemblies from AmerCable Systems

save you time & money!

� Fast Delivery� Job-site application evaluation

and consultation� Highly reliable cable assemblies

custom built and tested to spec

Fiber OpticSolutions

Top DriveService Loops

Page 36: World Class Oil & Gas Cables - Mercado Ideal GEXOL OIL AND GA… · 95°C Ratings Based on Table 4/3C.10 of the 1997 ABS MODU ... American Bureau of Shipping ... Highest ampacity

9_09© 2009, AmerCable Incorporated

10633 West Little York • Building #1 • Suite #100 • Houston, TX 77041 800-506-9473 • 713-896-5800 • Fax: 713-849-9009 • e-mail: [email protected] • www.amercable.com

®

Low smokehalogen-freefire resistantor flameretardant Type P cables.

SHF1, SHF2and NEK 606IEC cables

Precisionengineered cableassembliesfor hazardousand industrialapplications.

Top DriveServiceLoops

VFDCABLES

Crush andImpactResistant Type P cableswithoutexternalarmoring.

Foil shielded,power cablesengineered for use in variablefrequency AC driveapplications.

Available in severalconstructions

AmerCable is an ISO 9001 certified cable manufacturerthat combines leading-edge manufacturing technology,

innovative thinking, and high quality service to deliver the finest oil & gas cable andengineered cable assemblies available.

AmerCable serves the world from our Oil & Gas Group headquarters in Houston, Texas. Ourprofessional field engineers and sales force work withyou to create innovative, cost-effective project solutions.

What can you expect from AmerCable?� Fastest Lead Times in the Industry

� On-Time Delivery

� Professional Sales, Support and Service

� Productivity Solutions

� Global Cable Management

AmerCable’s manufacturing facility in El Dorado, Arkansas.