Woodpecker Wood Pellet Boiler
Mar 31, 2015
Woodpecker Wood Pellet Boiler
Biomass Heating in Republic of Ireland
• Fingal Co Council – Longford Town Council• Tipperary Co Council – Waterford Energy
Agency (Warm Homes)
Fingal Co Council
System Details•15k & 25kW Wood Pellet Boiler – Self Cleaning.•High efficiency wood pellet burner with approved burn back protection.•110 kg pellet hopper and auger system.•Pellet level sensor kit.•5 stage modulating digital combustion control system.
Other System Details
•Weatherproof external casing.•Various flue options available.•Delivery by flat pack or complete assembled system.•Note ‘tank in tank’ pellet storage – always dry
Accreditations
• Woodpecker residential boilers are MCS Accredited and qualify for the Renewable Heat Incentive (RHI)
• The RHI will provide home owners a guaranteed ‘fixed rate cash back’ for 15 years to users of qualifying biomass boilers
Clough, Ballymena, Co. Antrim
Clough, Ballymena, Co. Antrim
Clough, Ballymena, Co. Antrim
Reference Sites
• Northern Irish Housing Executive (NIHE) – sites at Bushmills, Ballynahinch, Mosside and Clogh – N.Ireland
• Highland Co Council – Scotland
• Fingal Co Council – Republic of Ireland
• Warm Homes Scheme – N Ireland and Republic of Ireland
Advantages of Cosyman Pellet Boiler
• Can be used where Oil in not an option
e.g Terraced House, No room for oil tank
• Fits through Std Door width
• Takes people out of Fuel Poverty - 30-40% cheaper than Oil
• Space Saving
Tests to EN 14785 :2006 – Residential Space Heating Appliances Fired by Wood Pellets
Tests to EN303-5 - HEATING BOILERS - PART 5: HEATING BOILERS FOR SOLID FUELS, HAND AND AUTOMATICALLY FIRED, NOMINAL HEAT OUTPUT OF UP TO 300 KW - TERMINOLOGY, REQUIREMENTS, TESTING AND MARKING Performance at Nominal Output
Information Supplied By :
Test results
Performance requirements in EN303-5 (class 3)
Pass/Fail
Efficiency, % 85.3 74.1 Pass
Organic Gaseous Compounds (OGC), mg/m3 at 10% O2
<100 Pass
NOx, mg/m3 at 10% O2 211.3 - n/a
Carbon Monoxide,mg/m3 at 10% O2
180.1 <3000 Pass
Particulates,mg/m3 at 10% O2
58.5 <150 Pass
Ref instandard
Mean Requirementof standard
Pass/Fail
Total efficiency, % 6.4.2 94.0 ≥ 75 P
Nominal heat output, (to water) kW
6.5 15.7 > manufacturer’s declaration
P
Mean CO emission (at 13% O2)
6.3 0.01 ≤ 0.04 P
Overall Assessment Pass