Top Banner
Wood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director – WoodWorks Texas Workshops – December, 2016
87

Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Feb 05, 2018

Download

Documents

duongthuy
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Wood-FrameShearWallandDiaphragmDesign

RickyMcLain,MS,PE,SE

TechnicalDirector– WoodWorks

TexasWorkshops–December,2016

Page 2: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Today’sMantra

Page 3: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Overview

• Diaphragms• Shearwalls

Page 4: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmDesign

Page 5: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

WindLoadDistributiontoDiaphragm

WINDINTODIAPHRAGMS

WINDSURFACELOADSONWALLS

Page 6: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

WindLoadPaths

WINDINTODIAPHRAGMSASUNIFORMLINEARLOADS

Page 7: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

WindLoadPaths

DIAPHRAGMSSPANBETWEEN

SHEARWALLS

WINDINTOSHEARWALLSASCONCENTRATEDLOADS

Page 8: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

StudtoDiaphragm

WINDLOAD

DIAPHRAGMSHEATHING

Floor/Roofframingperpendiculartowalls

FLOORJOIST

Page 9: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

StudtoDiaphragm

WINDLOAD

DIAPHRAGMSHEATHING

Floor/Roofframingparalleltowalls(addblocking)

FLOORJOIST

BLOCKING

Page 10: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

UnblockedDiaphragm

Page 11: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

UnblockedDiaphragmCapacity

• CapacitiesinSDPWSareNominal values.NotASD

DivideNominalValuesby2.0forASDCapacityMultiplyNominalValuesby0.8forLRFDCapacity

• CapacityisreducedforspecieswithSpecificGravity<0.5• ForSprucePineFirmultiplyby0.92

Page 12: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

BlockedDiaphragm

Page 13: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

BlockedDiaphragmCapacity

• CapacitiesinSDPWSareNominal values.NotASD

DivideNominalValuesby2.0forASDCapacityMultiplyNominalValuesby0.8forLRFDCapacity

• CapacityisreducedforspecieswithSpecificGravity<0.5• ForSprucePineFirmultiplyby0.92

Page 14: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ShearWallCapacitiesinAWCSDPWS

UnblockedBlocked

Page 15: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmTypes

CASE1DIAPHRAGM•HigherShearValues•Panelsperpendiculartofloorframingforimprovedperformance

CASES2-6Maybepreferredforlowsheardemandwherechangingframingdirectionhelps•HVACruns•FireBlocking/DraftStopping

RoofTrusses4x8sheathingN-S

Page 16: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmTypes

SDPWSTables4.2A&B

Page 17: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmAspectRatio

SDPWSTable4.2.4

Page 18: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

CalculatingDiaphragmForces

AWCDesignAid6

MaxShearatEnds

MaxMomentatMid-Span

Page 19: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

CalculatingDiaphragmForces

AWCDesignAid6

DiaphragmShear:• MaxShear=Diaphragm

ReactionatShearwall• DiaphragmUnitShear=

Reaction/LengthofDiaphragm=plf

Page 20: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

CalculatingDiaphragmForces

24’

72’

Diaphragm Fastener Schedule

Zone A12’

Zone A 12’Zone B 48’

Page 21: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Diaphragm– BendingMember

Tensionedge

Compressionedge

Page 22: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

CalculatingDiaphragmForces

AWCDesignAid6

DiaphragmChordForces:• MaxChordForceOccursat

LocationofMaxMoment• ChordForce=TorC• ChordForce=MMAX /

DiaphragmDepth• ChordUnitShear=ChordForce

/LengthofDiaphragm=plf

Page 23: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmChords

WallTopPlatesTypicallyFunctionasBothDiaphragmChordsandDragStruts

Page 24: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmBoundary

Strut

Strut

Chor

dCh

ord

Strut

Chor

d

SW1 – 10’ SW2 – 10’

SW3 – 16’

1 2 3

B

A

Strut

Stru

t

W =

200

plf

24’

80’

Reaction = 200 plf * 24’/2 = 2400 lbsDiaphragm Only at Shearwall = 2400 lbs / 16’ = 150 plf

Page 25: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmBoundary

Strut

Strut

Chor

dCh

ord

Strut

Chor

d

SW1 – 10’ SW2 – 10’

SW3 – 16’

1 2 3

B

A

Strut

Stru

t

W =

200

plf

Does this mean that no drag struts are required?

24’

80’

Page 26: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmBoundary

Alledgesofadiaphragmshallbesupportedbyaboundaryelement.(ASCE7-10Section11.2)

• DiaphragmBoundaryElements:• Chords,dragstruts,collectors,Shearwalls,frames

• Boundarymemberlocations:• Diaphragmandshearwall perimeters• Interioropenings• Areasofdiscontinuity• Re-entrantcorners.

Page 27: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

AssumeBasicWindSpeed=115mphUltimate

ExposureB

DiaphragmDesign

• Capacity

Shearwall Design

• Conventional• ForceTransferAroundOpening• PerforatedShearwall

Example:RetailRestaurant

Page 28: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

RetailRestaurant– DiaphragmDesign

CriticalShearwall atfrontofbuilding

CheckDiaphragmforwindloadson84’wall

84’

34’

10’6’ 8’5’

6’

6’

6’

6’

6’

3’3’

4’

29’24’

Page 29: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmAspectRatios

SDPWSTABLE4.2.4

TYPE- MAXIMUMLENGTH/WIDTHRATIO

Foran84x34diaphragmtheaspectratiois2.5<3.

DiaphragmaspectratioisOK.

Woodstructural panel,unblocked 3:1

Woodstructural panel,blocked 4:1

Single-layerstraight lumbersheathing 2:1

Single-layerdiagonallumbersheathing 3:1

Double-layerdiagonallumbersheathing 4:1

Page 30: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

CalculatingMWFRSWindLoads

CalculatewindpressureusingDirectionalMethod(ASCE7Chpt 27)

p=qh[(GCpf)-(GCpi)]

qh =0.00256*0.57*1.0*0.85*1152*1=16.4psf

GCpf =0.85*[0.8– (-0.3)]=0.935

GCpi =0.18- 0.18=0

p=(16.4psf)(0.935)=15.34psf

0.6*W=0.6*15.34=9.2 psf onwalls

Usemin9.6psf perASCE27.1.5

ASCE7-10Figure27.4-1

Page 31: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ParapetDesign– Figure27.6-2

Atparapetswindwardandleewardpressuresoccuroneachparapet.

Section27.4.5:Pp =q(GCpn)GCpn =1.5Windwardparapet,-1.0LeewardparapetWindwardParapetGCpf is1.5:16.4*1.5*0.6=14.76psfLeewardParapetGCpf is1.0:16.4*1.0*0.6=9.84psfNetParapet=14.76+9.84=24.6psf

Page 32: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

RetailRestaurant– DiaphragmDesign

84’

34’

10’6’ 8’5’

6’

6’

6’

6’

6’4’

29’24’

10’

3’3’

W=(9.6psf*(5’+3’)+(24.6)*3’)=150.6plfV=(150.6plf)*(84’/2)=6,325lbM=(150.6plf)*(84’2)/2=531,317lb*ftT=C=(531,317lb*ft)/(34ft)=15,627lb

νdiaphragm =6,325lb/34’=186plfνdiaphragm =15,627lb/84’=186plf

P

Page 33: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

DiaphragmCapacity:SDPWSTable4.2C

PANELGRADE

COMMONNAILSIZEORSTAPLEf

LENGTHANDGAGE

MINIMUMFASTENERPENETRATIONINFRAMING

MINIMUMPANELTHIICKNESS

MINIMUMNOMINALWIDTHOFFRAMINGMEMBERSATADJOININGPANELEDGESANDBOUNDARIESg

NAILSPACINGATALLPANELEDGES

Case1(Nounblockededgesorcontinuousjointsparalleltoload)

Allotherconfigurations(Cases2,3,4,5and6)

Sheathing&singlefloor

8d(2½“x0.131”)

13/8”

7/16”

2IN. 6IN. 460(Seismic)645(Wind)

340(Seismic)475(Wind)

3IN. 6IN. 510(Seismic)715(Wind)

380(Seismic)530(Wind)

CapacityisreducedforspecieswithSpecificGravity<0.5.ForSprucePineFirmultiplyby0.92

Capacity =(645plf)(0.92)/2 =297plf297plf >186plf,diaphragmisadequatewithsheathing&fasteningasshownabove

Page 34: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

SmallOpeningsinDiaphragms

http://cwc.ca/wp-content/uploads/2013/11/Design-example-of-designing-for-openings-in-wood-diaphragm.pdf

Accountingforopeningsinshearpanels(diaphragmsandshearwalls)isacoderequirement(IBC2305.1.1)

Nocodepathforcheckingminimumsizeopeninglimit(otherthanprescriptivedesign– IBC2308.4.4.1&2308.7.6.1)

Doyouneedtoaccountfora

12”squareopeninginadiaphragm?

Page 35: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

SmallOpeningsinDiaphragms

FPInnovationsmethodforcheckingsmallholesindiaphragms:

Recommendrunningananalysisoftheopening’seffectsonthediaphragmunlessthefollowingconditionsaremet.

Page 36: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Overview

• Diaphragms• Shearwalls

Page 37: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

WindLoadscreateshear(sliding)andrackingforcesonastructure

Slidingresistedbyshearwall baseanchorageRackingresistedbyshearpanel&fasteners

Shearwall Functions

Page 38: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ComponentsofShearWallDesign

Collector&DragDesign

ShearWallConstruction

ShearTransferDetailing

ShearResistance

Page 39: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ShearWallConfigurationOptions

SolidorSegmentedWalls

PerforatedWallsForceTransferAround

OpeningsWalls

MaximumASDCapacityof870plf (Seismic)1217plf (Wind)

Useful,IfNecessary.

Page 40: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwalls

HOLD-DOWN

WSPSHEATHING

ANCHORBOLTS

WOODSTUDS

Page 41: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

RackedShearwall

EDGENAILINGPROVIDESRACKINGRESISTANCE

Page 42: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

PanelFasteners

Page 43: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwalls

ANCHORBOLTSTOFOUNDATION

PREVENTSLIDING!

Page 44: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Hold-DownsResistEndUplift

HOLD-DOWNS

Page 45: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ShearWallRequirementsinAWCSDPWS

3:5:1maxaspectratioforblockedWoodStructuralPanelShearWall.

ReductioninCapacitywhengreaterthan2:1

WoodEducation Institute

Page 46: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwall AspectRatio

NDSSDPWSTABLE4.3.4

MAXIMUMSHEARWALLDIMENSIONRATIOS

SeeSDPWSTable4.3.4forfootnotes

Woodstructural panels,blocked Forotherthanseismic:3½:11

Forseismic:2:11

Woodstructural panels,unblocked 2:1

Diagonalsheathing,single 2:1

StructuralFiberboard 3½:13

Gypsumboard,portland cementplaster 2:12

L

H

AR=H/L

Page 47: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

WSPShearwall Capacity

• CapacitieslistedinAWC’sSpecialDesignProvisionsforWindandSeismic(SDPWS)

• Sheathedshearwallsmostcommon.Canalsousehorizontalanddiagonalboardsheathing,gypsumpanels,fiberboard,lathandplaster,andothers

• Blockedshearwallsmostcommon.SDPWShasreductionfactorsforunblockedshearwalls

• Notethatcapacitiesaregivenasnominal:mustbeadjustedbyareductionorresistancefactortodetermineallowableunitshearcapacity(ASD)orfactoredunitshearresistance(LRFD)

Page 48: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwall Capacity- SDPWSChpt 4

Page 49: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwall Capacity- SDPWSChpt 4

Page 50: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwall Capacity- SDPWSChpt 4

Capacitybasedonblockedshearwall.Reducecapacitiesforunblocked

Page 51: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ComponentsofShearWallDesign

Holdown

Anchorage

BoundaryPosts

Compression

Tension

Page 52: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwall HoldDowns

Source:DartDesignInc.com

Source:strongtie.com

BucketStyle

Page 53: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwall HoldDowns

Straps

Source:strongtie.com

Page 54: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ComponentsofShearWallDesign

Accumulatedtensionfromframingtohardwaretoframingateachfloorlevel

1kip

2kips

3kips

7k

4k

1.5k 1.5k

1.5k

4k

4k

7k

7k

Overturningrestrained

connectionatbottomofstory

20ft

10ft,typ

DiscreteHoldown Systems

Page 55: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ComponentsofShearWallDesign

Collector&DragDesign

ShearWallConstruction

ShearTransferDetailing

ShearResistance

Page 56: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ShearTransferDetailing

Source:WoodWorks Five-StoryWood-FrameStructureoverPodiumSlabDesignExample

Page 57: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ShearTransferDetailing

Source:WoodWorks Five-StoryWood-FrameStructureoverPodiumSlabDesignExample

Designacompleteloadpath

Page 58: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ComponentsofShearWallDesign

Collector&DragDesign

ShearWallConstruction

ShearTransferDetailing

ShearResistance

Page 59: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

LoadPath,LoadPath,LoadPath…

IBC1604.4Analysis. Loadeffects onstructuralmembersandtheirconnectionsshallbedeterminedbymethodsofstructuralanalysisthattakeintoaccountequilibrium,generalstability,geometriccompatibilityandbothshort- andlong-termmaterialproperties.

[…]

Anysystemormethodofconstructiontobeusedshallbebasedonarationalanalysisinaccordancewithwell-established principlesofmechanics.Suchanalysis shall resultinasystemthatprovidesacompleteloadpathcapableoftransferring loads fromtheirpointoforigintotheload-resisting elements.

Resources:

TheAnalysisofIrregularShapedDiaphragms. WhitepaperbyR.TerryMalonehttp://www.woodworks.org/wp-content/uploads/Irregular-Diaphragms_Paper1.pdf

TheAnalysisofIrregularShapedStructures. TextbookbytheR.TerryMalone

NEHRPSeismicDesignTechnicalBrief.SeismicDesignofWoodLight-FrameStructuralDiaphragmSystems:AGuideforPracticingEngineers

http://www.nehrp.gov/library/techbriefs.htm

Collector&Drag(Diaphragm)Design

Page 60: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

RetailRestaurant– Shearwall Design

84’

34’

10’6’ 8’5’

6’

6’

6’

6’

6’4’

29’24’

10’

3’3’

P =6,325lb – fromdiaphragmcalcs usingDirectionalMethod

Let’sseewhathappenswhenweuseEnvelopeMethodtocalculateMWFRSloadstofrontshearwall

P

Page 61: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

CalculatingMWFRSWindLoads

CalculatewindpressureusingEnvelopeMethod(ASCE7Chpt 28)

p=qh[(GCpf)-(GCpi)]

qh =0.00256*0.70*1.0*0.85*1152*1=20.14psf

GCpf (Zones1&4) =0.4– (-0.29)=0.69(ASCE7Fig.28.4-1)

GCpf (Zones1E&4E) =0.61– (-0.43)=1.04(ASCE7Fig.28.4-1)

GCpi =0.18- 0.18=0

P1&4=(20.14psf)(0.69)=13.9psf;0.6*W=0.6*13.9=8.3psf wallstyp.

P1E&4E=(20.14psf)(1.04)=20.9psf;0.6*W=0.6*20.9=12.5psf wallscrnr

ASCE7-10Figure28.4-1

Page 62: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

CalculatingMWFRSWindLoads

ASCE7-10Figure28.4-1

a=Lesserof:

• 10%leasthorizontaldimension(LHD)34’*0.1=3.4’

• 0.4h=0.4*13’=5.2’.Butnotlessthan:

• 0.04LHD=1.4’or3’

Usea=3.4’forzones1E&4E

2a=3.4’*2=6.8’

Page 63: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ParapetDesign– Section28.4.2

Atparapetswindwardandleewardpressuresoccuroneachparapet.

Section28.4.2:Pp =q(GCpn)GCpn =1.5Windwardparapet,-1.0LeewardparapetWindwardParapetGCpf is1.5:20.14*1.5*0.6=18.12psfLeewardParapetGCpf is1.0:20.14*1.0*0.6=12.08psfNetParapet=18.12+12.08=30.2psf

Page 64: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

RetailRestaurant– Shearwall Design

84’

34’

10’6’ 8’5’

6’

6’

6’

6’

6’4’

29’24’

10’

3’3’

P

6.8’12.5psf8.3psf

77.2’

P=(8.3psf*(5’+3’)+(30.2)*3’)*(84’/2)+((12.5psf-8.3psf)*(5’+3’))*6.8’*(77.2’/84’)=6,804lb(forcomparison:Directionalmethodgaveus6,325lb)

Page 65: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Shearwall AspectRatios

10’

3’3’

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

• CheckAspectRatios:AssumeblockedWSPShearwall• 10’/2’=5>3.5;Inadequate• 10’/6’=1.67<3.5;OK

FrontWallElevation

Page 66: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

• CheckAspectRatios:AssumeblockedWSPShearwall• 10’/2’=5>3.5;Inadequate• 10’/6’=1.67<3.5;OK

Shearwall AspectRatios

10’

3’3’

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

νshearwall =6,804lb/12’=567plf

Page 67: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ConventionalShearwall Capacities

νshearwall =567plf

Assume15/32”,StructuralIsheathingattachedwith8dnails

NominalTabulatedCapacity=1540plfAdjustedASDCapacity =(1370plf)(0.92)/2=630plf630plf >567plf,OK8dnailsat3”o.c.acceptable

PANELGRADE FASTENERTYPE&SIZE

MINIMUMPANELTHIICKNESS

MINIMUMFASTENERPENETRATIONINFRAMING

NAIL SPACINGATALLPANELEDGES

PANEL EDGEFASTENERSPACING

WoodStructuralPanels–Sheathing

8d(2½“x0.131”)

15/32” 13/8” 3IN. 980(Seismic)1370(Wind)

SDPWSTable4.3A

Page 68: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ConventionalShearwall Overturning

νshearwall =567plfHolddownsrequiredatshearwallsT=νhT=567plf*10’=5,670lb

Holddowncapacity=7,045lbManyavailableprefabricatedholddownswithcapacitieslistedbymanufacturers

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

Page 69: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Hold-DownAnchor

Page 70: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ConventionalShearwall Overturning

νshearwall =567plfPostsarealsorequiredatendsofthewalltoresistcompressionforcesC=T=νhC=567plf*10’=5,670lb

6’ 6’ 6’ 6’ 6’2’ 2’

10’

SizepostforbearingonwallsoleplateAssume2x6wall,Requiredpostwidth=5,670lb/(565psi)(5.5in)=1.8in;Use2-2x6postmin.

Page 71: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ConventionalShearwall BaseAnchorage

• νshearwall =567plf• ½”AnchorBoltcapacityforwoodbearing=680lb*1.6=1,088lb

perNDSTable11E• Spacing=1088lb/567plf =1’-11”o.c.max.

Page 72: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Hold-Downs:Segmentedv.Perforated

SegmentedShearwall

PerforatedShearwall

Page 73: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

PerforatedShearWallMethod

HOLDDOWNSATENDOFWALL

WSPSHEATHING

Fewerholddownsrequired,shearcapacityisreduced

Uniformupliftatbaseofwallrequired– magnitude=shearforce– SDPWS4.3.6.4.2.1

Page 74: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

• CheckAspectRatios:AssumeblockedWSPShearwall• 10’/2’=5>3.5;Inadequate• 10’/6’=1.67<3.5;OKUseonlyfullheightsheathedsectionstoresistshear

PerforatedShearwall Design

10’

3’3’

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

νshearwall =6,804lb/12’=567plf

TotalPerforatedShearwall

Page 75: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

PerforatedShearwall Capacity

Wallhas12’/18’=67%fullheightsheathing,max.openingH=6’-8”

Multiplycapacityby0.75foropening2H/3

Reducedcapacityis630plf*0.75=473plf <567plf,Inadequate

SDPWSTable4.3.3.5

Page 76: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

PerforatedShearwall Capacity

νshearwall =567plf

Tryreducingnailspacingto2”with8dnails– willrequire3xframing

NominalTabulatedCapacity=1790plfAdjustedASDCapacity=(1790plf)(0.92)(0.75)/2=618plf618plf >567plf,OK8dnailsat2”o.c.acceptableforperforatedwall

PANELGRADE FASTENERTYPE&SIZE

MINIMUMPANELTHIICKNESS

MINIMUMFASTENERPENETRATIONINFRAMING

NAIL SPACINGATALLPANELEDGES

PANEL EDGEFASTENERSPACING

WoodStructuralPanels–Sheathing

8d(2½“x0.131”)

15/32” 13/8” 2IN. 1280(Seismic)1790(Wind)

SDPWSTable4.3A

Page 77: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

PerforatedShearwall Overturning

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

νshearwall =567plfHolddownsrequiredatendsofperforatedwallT=νh/CoT=567plf*10’/0.75=7,560lb

Holddowncapacityfromsegmentedwalloption=7,045lb,Inadequate– needtoselecthighercapacityholddown

Page 78: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

PerforatedShearwall Uplift

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

νshearwall =567plf/0.75=756plf,usesamemagnitudeforuniformupliftatfullheightsegmentsOneoptionistouseanchorboltswithlargewasherstoresistupliftinbearingIfnetwasherarea=8in2,canresist(565psi)(8in2)=4,520lb inuplift• Max.anchorboltspacing=4,520lb/756plf =5’-11”o.c.• Willalsoneedtocheckshearloadsonanchorboltsforcontrolling

case

Page 79: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ForceTransferAroundOpening(FTAO)

Page 80: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

FTAOShearwalls Methodologies

• Shearwall designmethodologywhichaccountsforsheathedportionsofwallaboveandbelowopenings(perforatedneglects)

• Openingsaccountedforbyreinforcingedgesusingstrappingorframing

• SDPWS4.3.5.2providesspecificrequirements• H/Lratiodefinedbywallpier• Min.wallpierwidth=2’-0”

• Reducednumberofholddowns(onlyatendsoftotalwall)

• Thereare3mainmethodsofFTAOanalysis;SDPWSdoesnotrequireoneparticularmethodbeused,onlythatdesignis“basedonarationalanalysis”• DragStrut,CantileverBeam,&Diekmann DesignOptions

Page 81: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

WhyUseForceTransferAroundOpenings?

Fullheightwallpiersdonotmeetmax3.5:1Ratio

8feettall2feetwide8/2=4>3.5NotAShearwall!

Page 82: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

WhyUseForceTransferAroundOpenings?

ShorterConstrainedpiersdomeet3.5:1max

aspectratio

5feettall2feetwide5/2=2.5< 3.5CanbeaShearWall!

Page 83: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ReferencesforFTAODesign

APAAuthoredSEAOCPaperhttps://www.apawood.org/Data/Sites/1/documents/technicalresearch/seaoc-2015-ftao.pdf

SEAOCStructural/SeismicDesignManual,Volume2Providesnarrativeandworkedoutexample

DesignofWoodStructuresTextbookbyBreyeretal.

Page 84: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Double-SidedShearwalls

High-strengthwoodshearwallscanbedouble-sidedwithWSPsheathingoneachside:SDPWS4.3.3.3SummingShearCapacities:Forshearwallssheathedwiththesameconstructionandmaterialsonoppositesidesofthesamewall,thecombinednominalunitshearcapacity shallbepermittedtobetakenastwicethenominalunitshearcapacityforanequivalentshearwallsheathedononeside(4.3.5.3hasmaxcapacitiesfordouble-sidedperforatedwalls)

Page 85: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Double-SheathedShearwalls

Thereisalsoanoptiontohaveasinglesided,doublesheathedshearwall.

TestingandreportbyAPAconcludethatitispermissibletousethecapacityofthewallthesameasiftherewasonelayerofWSPoneachsideofthewallprovidedthatanumberofcriteriaaremetincluding:• Framingmembersatpanel

jointsare3xor2-2x• Minimumnailspacingis4”• Others

Page 86: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

Questions?

ThisconcludesTheAmericanInstituteofArchitectsContinuingEducationSystemsCourse

RickyMcLain,MS,PE,SE

TechnicalDirector- WoodWorks

[email protected]

(802)498-3310

Visitwww.woodworks.org formoreeducationalmaterials,casestudies,designexamples,aprojectgallery,andmore

Page 87: Wood-Frame Shear Wall and Diaphragm · PDF fileWood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director –WoodWorks Texas Workshops –December, 2016

ThispresentationisprotectedbyUSandInternationalCopyrightlaws.

Reproduction,distribution,displayanduseofthepresentationwithoutwrittenpermission

ofthespeakerisprohibited.

©TheWoodProductsCouncil2016

CopyrightMaterials