M ) c ) ) c c FLORIDA LICENSE NUMBER05371 901 W Garden St Pensacola, FL 325 P 850-438-0050 F 850-432-8631 - UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS, 1 JUNE 2013 - UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 9 FEBRUARY 2012, WITH CHANGE 1, 1 OCTOBER 2013 - UFC 4-010-02, DOD MINIMUM ANTITERRORISM STANDOFF DISTANCE FOR BLDG.'s, 9 FEBRUARY 2012. 2. ALL REFERENCED STANDARDS REFER TO THE EDITION IN FORCE AT THE TIME THESE PLANS AND SPECIFICATIONS ARE ISSUED. 3. REVIEW ALL CONTRACT DOCUMENTS, DIMENSIONS AND SITE CONDITIONS AND COORDINATE WITH FIELD DIMENSIONS AND PROJECT SHOP DRAWINGS PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES IN WRITING TO CONTRACTING OFFICER. DO NOT CHANGE SIZE OR DIMENSIONS OF STRUCTURAL MEMBERS WITHOUT WRITTEN INSTRUCTIONS FROM THE STRUCTURAL ENGINEER OF RECORD. 4. ANY DISCREPANCIES, OMISSIONS OR VARIATIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS DISCOVERED DURING THE BIDDING PERIOD SHALL BE IMMEDIATELY COMMUNICATED IN WRITING TO THE CONTRACTING OFFICER. 5. PROTECT EXISTING FACILITIES, STRUCTURES AND UTILITY LINES FROM ALL DAMAGE. THE CONTRACTOR SHALL PROTECT HIS WORK, ADJACENT PROPERTY AND THE PUBLIC. EACH CONTRACTOR IS SOLELY RESPONSIBLE FOR DAMAGE OR INJURY DUE TO HIS ACT OR NEGLECT. 6. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND SUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 7. DO NOT SCALE DRAWINGS; USE DIMENSIONS. 8. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF OPENINGS IN STRUCTURE NOT SHOWN ON STRUCTURAL DRAWINGS. 9. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS APPLY TO ALL SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETHER OR NOT THEY ARE KEYED IN AT EACH LOCATION. QUESTIONS REGARDING APPLICABILITY OF TYPICAL DETAILS SHALL BE RESOLVED BY THE CONTRACTING OFFICER. 10. ALL WIND FORCES SHALL BE DETERMINED ACCORDING TO ASCE 7-2010 FOR THE MINIMUM WIND CRITERIA STATED BELOW, INCLUDE ALL APPROPRIATE SHAPE, HEIGHT, AND GUST FACTORS FOR THE MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS, AND CLADDING. TO CALCULATE THE MAXIMUM NET ROOF UPLIFT, USE A DEAD LOAD OF 5 PSF. FOR ROOF ATTACHMENTS USE THE LOADS DIRECTLY FROM THE CLADDING DIAGRAM. ) c c ) 12. ALL WINDOWS, DOORS, LOUVERS, SKYLIGHTS, ETC. AND THEIR ATTACHMENTS TO THEIR STRUCTURAL FRAME SHALL BE DESIGNED TO RESIST ALL INTERNATIONAL BUILDING CODE 2012 EDITION, ASCE 7-10, AND UFC 4-010-01 LOAD REQUIREMENTS INCLUDING BUT NOT LIMITED TO WIND LOADS, AND BLAST RESISTANCE. ALL WINDOWS, SKYLIGHTS, ETC. SHALL BE DESIGNED BY THEIR SYSTEMS ENGINEER AND PROVIDED AS A SYSTEM INCLUDING ANY REQUIRED INTERMEDIATE SUPPORT AND THEIR ATTACHMENTS TO THE MAIN STRUCTURAL FRAME. 13. ALL PROPRIETARY SYSTEMS OR ACCESSORIES DESIGNATED IN THESE PLANS AS "OR EQUAL" MAY BE SUBSTITUTED WITH ANOTHER SYSTEM THAT HAS LOAD CAPACITY GREATER THAN OR EQUAL, AND DEFLECTION LESS THAN OR EQUAL TO THE SYSTEM DESIGNATED. APPROVAL SHALL BE REQUESTED FOR ANY SUBSTITUTIONS BY THE ENGINEER OF RECORD THROUGH AN RFI. THE CONTRACTOR SHALL BE HELD FINANCIALLY RESPONSIBLE FOR THE REPLACEMENT OF UNAPPROVED SUBSTITUTIONS WHICH ARE NOT EQUIVALENT TO THE DESIGNATED SYSTEM OR ACCESSORY. 14. ALL PROPRIETARY SYSTEMS AND ACCESSORIES SHALL BE INSTALLED WITH STRICT ADHERENCE TO MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. 15. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS REFERENCES THE FINISHED FLOOR ELEVATION OF THE FIRST FLOOR. REFER TO THE CIVIL DRAWINGS FOR ACTUAL DATUM ELEVATION. Vmark| ^ddvl I SIZE: I ANSI D I PLOT SCALE: (DESIGNED BY: I S.SMITH 1. ALL STEEL WORK (INCLUDING FABRICATION AND ERECTION) SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION 14TH EDITION AND PROJECT SPECIFICATIONS, USE THE FOLLOWING: A. ROLLED SHAPES, ASTM A992, GRADE 50. B. PLATES BARS A36. C. COLD-FORMED STEEL TUBING: ASTM A500, GRADE B. D. HOT-FORMED STEEL TUBING: ASTM A501. E. STEEL PIPE: ASTM A53, TYPE E OR S, GRADE B. 2. USE STRUCTURAL STEEL THAT IS FULLY WELDABLE WITHIN GRADES AND FROM ANY GRADE TO ANY OTHER GRADE. WELD ALL SHOP CONNECTIONS, U.N.O. 3. ALL SHOP AND FIELD WELDING SHALL CONFORM TO THE STRUCTURAL WELDING CODE AWS D1.1, LATEST EDITION, PUBLISHED BY THE AMERICAN WELDING SOCIETY (AWS). USE ELECTRODES CONFORMING TO AWS D1.1, E70 SERIES, U.N.O. SHOW ALL SHOP WELDS ON THE FABRICATION DRAWINGS AND ALL FIELD WELDS ON THE ERECTION DRAWINGS. 4. ALL SHOP AND FIELD WELDERS, WELDING OPERATORS, AND TACKERS SHALL BE CERTIFIED ACCORDING TO AWS PROCEDURES FOR THE WELDING PROCESS AND WELDING POSITION USED. 5. ALL JOINT WELDING PROCEDURES TO BE USED SHALL BE PREPARED BY THE FABRICATOR OR CONTRACTOR AS WRITTEN PROCEDURE SPECIFICATIONS AND SUBMITTED TO THE CONTRACTING OFFICER FOR THEIR RECORD. ALL JOINT WELDING PROCEDURES SHALL BE QUALIFIED PRIOR TO USE ACCORDING TO AWS PROCEDURES. 6. A325 BOLTS: A. A325 BOLTS SHALL CONFORM TO ASTM A 325 TYPE 1, HIGH STRENGTH BOLTS FOR STRUCTURAL STEEL JOINTS. DO NOT USE TYPE 2 BOLTS. B. PROVIDE HARDENED WASHERS CONFORMING TO ASTM F 436. PLACE HARDENED WASHERS UNDER PART BEING TURNED. C. LOAD INDICATOR WASHERS OR BOLTS SHALL BE USED ON ALL A325 BOLTS. D. ALL BOLTS SHALL BE NEW AND DOMESTICALLY MANUFACTURED. DO NOT REUSE BOLTS. USE ONLY NON-GALVANIZED NUTS AND BOLTS THAT ARE CLEAN, RUST-FREE, AND WELL LUBRICATED. 7. USE F1554 BOLTS FOR ANCHOR BOLTS OR WHEN SPECIFICALLY CALLED FOR ON THE DRAWINGS. 8. CUT, DRILL, OR PUNCH HOLES PERPENDICULAR TO METAL SURFACES. DO NOT FLAME CUT HOLES OR ENLARGE HOLES BY BURNING. 9. SPLICING OF STRUCTURAL STEEL MEMBERS IN THE FIELD OR IN THE SHOP IS PROHIBITED EXCEPT WHERE INCLUDED ON THE DRAWINGS. 10. DO NOT PAINT STEEL SURFACES IN CONTACT WITH CONCRETE. DO NOT APPLY FINISH COAT AND LIMIT PRIME COAT TO 2 MILS AT FAYING SURFACES OF SLIP CRITICAL BOLTED CONNECTIONS, SURFACES TO BE WELDED AND TOP SURFACES OF BEAMS AND TRUSSES TO RECEIVE STEEL STUDS AND/OR SUPPORTING METAL FLOOR AND ROOF DECKING. USE PRIMER WHICH HAS A MIN. CLASS A SLIP COEFFICIENT (0.33). 11. REFER TO SPECIFICATIONS FOR PAINTING OF STRUCTURAL STEEL 12. SUBMIT STRUCTURAL STEEL SHOP DRAWINGS TO COTR FOR REVIEW BEFORE FABRICATION. 13. PROVIDE TEMPORARY BRACING AS NECESSARY TO INSURE A STABLE STRUCTURE DURING CONSTRUCTION. 14. DO NOT REPRODUCE THE STRUCTURAL DRAWINGS FOR USE AS SHOP DRAWINGS. 15. NO CUTTING OF SECTIONS, FLANGES, WEBS OR ANGLES SHALL BE ALLOWED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. 16. ALL EXPOSED STEEL MEMBERS & CONNECTIONS SHALL BE HOT DIP GALVANIZED PRIOR TO FABRICATION. ALL CONNECTIONS SHALL BE PRE DRILLED AND/OR WELDED PRIOR TO HOT DIP GALVANIZING. 17. SLIP CRITICAL JOINTS SHALL HAVE CLASS A FAYING SURFACES WITH SLIP CHECKED AT THE FACTORED LOAD LEVEL. 1. USE STRUCTURAL CONCRETE AND CONCRETING PRACTICES CONFORMING TO ACI-301, ACI-318, AND PROPORTION CONCRETE IN ACCORDANCE WITH ACI-318 CH. 4 AND MEETING A MINIMUM ULTIMATE COMPRESSIVE STRENGTH IN 28 DAYS AS FOLLOWS: -FOOTINGS 4000 PSI -SLABS ON GRADE 4000 PSI -ALL OTHER CONCRETE 4000 PSI PROVIDE CURRENT (MAX 1 YEAR OLD) STATISTICAL DATA FOR EACH CONCRETE MIX DESIGN SUBMITTED. 2. WHERE CONCENTRATION OF REINFORCING STEEL HINDERS PROPER CONSOLIDATION OF CONCRETE USE CONCRETE CONTAINING A SUPERPLASTICIZING (N.R.W.R.)ADMIXTURE, ASTM C494 TYPE F. SLUMP AFTER ADDITION OF SUPERPLASTICIZER SHALL BE 9"±1". 3. IF CONCRETE IS PUMPED, SLUMP MAY BE INCREASED TO 6" AT THE TRUCK, PROVIDED THE SLUMP SPECIFIED IN NOTE 2 IS MAINTAINED AT THE DISCHARGE END.USE A MINIMUM 4- INCH PUMP, UNLESS PRE-APPROVED BY THE ARCHITECT. TAKE CONCRETE SAMPLES FOR SLUMP AT TRUCK AND AT DISCHARGE END. TAKE CONCRETE SAMPLES FOR CYLINDER TESTING AT DISCHARGE END. 4. USE ASTM A-615 GR. 60 FOR ALL REINFORCING STEEL, CONFORM TO ACI-301, ACI-315, ACI-318, AND CRSI "MANUAL OF STANDARD PRACTICE:. ALL REINFORCING SHALL BE ACCURATELY PLACED, RIGIDLY SUPPORTED AND FIRMLY TIED IN PLACE WITH BAR SUPPORTS AND SPACERS IN ACCORDANCE WITH THE ABOVE REQUIREMENTS. PROVIDE CLASS B LAP SPLICE FOR CONTINUOUS BARS, U.N.O. LAP BOTTOM STEEL OVER SUPPORTS AND TOP STEEL AT MIDSPAN UNLESS OTHERWISE SPECIFIED. HOOK DISCONTINUOUS ENDS OF ALL TOP BARS AND ALL BARS IN WALLS, U.N.O. USE 1" COVER OVER REINFORCING EXCEPT AS FOLLOWS: BOTTOM TOP SIDES FOOTINGS 3" 2" 3" SLABS ON GRADE 2" 1" 2" POURED WALLS RETAINING FILL - - 2" * POURED WALLS ABOVE GROUND - - 3/4" NOTE: * = 2" FOR #6 BARS AND LARGER. 1-1/2" FOR #5 BARS AND SIMILAR. 5. USE PLAIN, COLD-DRAWN, ELECTRICALLY WELDED, STEEL WIRE FABRIC CONFORMING TO ASTM A-185. SUPPLY IN FLAT SHEETS ONLY. LAP SPLICES SHALL BE MEASURED BETWEEN OUTERMOST CROSS WIRES OF EACH FABRIC SHEET AND SHALL BE NOT LESS THAN TWICE THE SPACING OF THE CROSS WIRES PLUS TWO (2) INCHES 6. THE GROUND FLOOR SLAB SHALL BE UNDERLAIN BY A MINIMUM 10 MIL. VAPOR RETARDER ON 6" MINIMUM CLEAN SAND CAPILLARY BARRIER. 7. SLEEVE ALL PIPES THRU SLABS ON GRADE INDIVIDUALLY. OPENINGS LARGER THAN 6", NOT SHOWN ON STRUCTURAL DRAWINGS, SHALL REQUIRE SHOP DRAWINGS SHOWING SIZE AND LOCATION FOR COTR APPROVAL. PROVIDE (1)-#5x4'-0" E.W. PLACED DIAGONALLY AT MID DEPTH AROUND ALL OPENINGS LARGER THAN 12" UNLESS OTHERWISE NOTED ON DRAWINGS. NO CONDUIT SHALL BE EMBEDDED IN SLAB WITHOUT PRIOR APPROVAL FROM THE CONTRACTING OFFICER. 8. SUBMIT SHOP DRAWINGS FOR ALL REINFORCING STEEL TO COTR FOR APPROVAL PRIOR TO FABRICATION. 1. ALL MASONRY WORK IS TO CONFORM TO ACI 530 AND 530.1. 2. CONSTRUCT REINFORCED MASONRY AS NOTED ON THE PLANS AND DETAILS IN ACCORDANCE WITH THE REQUIREMENTS OF MASONRY SPECIFICATION SECTIONS. UNREINFORCED MASONRY SHALL NOT BE USED. 3. USE CONCRETE MASONRY UNITS CONFORMING TO ASTM C90. PROVIDE f'm OF 1500 PSI (UNIT STRENGTH 1900 PSI) FOR ALL REINFORCED MASONRY SHEAR WALLS. PERFORM f'm AND C90 COMPLIANCE BY UNIT STRENGTH METHOD. 4. USE TYPE "S" MORTAR IN ACCORDANCE WITH ASTM C270. USE 3/8" FULL-BEDDED JOINTS FOR ALL MASONRY UNITS. REMOVE MORTAR PROTRUDING INTO CELL CAVITIES THAT ARE TO BE REINFORCED AND GROUTED. ALLOW A MIN. OF 24 HOURS FOR MORTAR TO CURE BEFORE PLACING GROUT. 5. USE ALL GROUT CONFORMING TO ASTM C-476 WITH A MIN. COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS, TESTED IN ACCORDANCE WITH ASTM C1019. AGGREGATE TO CONFORM TO ASTM C404 FOR COARSE GROUT AND SLUMP OF 8" TO 11". TEST SAMPLES FOR COMPRESSIVE STRENGTH. TEST EVERY 30 YARDS OR EACH DAY'S GROUTING. 6. FOR REINFORCED MASONRY USE HEAVY DUTY (3/16" SIDE RODS WITH 9 GAUGE CROSS RODS) LADDER TYPE HORIZONTAL JOINT REINFORCING IN EVERY OTHER COURSE U.N.O. USE PREFABRICATED CORNERS AND TEES AT WALL INTERSECTIONS. OVERLAP DISCONTINUOUS ENDS A MIN. OF 12". HORIZONTAL REINFORCING SHALL CONFORM TO ASTM A-82. 7. FOR MASONRY CAVITY WALLS, HORIZONTAL JOINT REINFORCING SHALL BE HEAVY DUTY (3/16" SIDE RODS WITH 9 GAUGE CROSS RODS) LADDER TYPE. VERTICAL SPACING OF REINFORCING SHALL BE 16" O.C. MAX. WITH 8" O.C. MAX AT BUILDING CORNERS (SEE WIND CLADDING DIAGRAM FOR CORNER DIMENSION) TIES SHALL BE LOCATED WITHIN 8" OF WALL DISCONTINUITIES (MCJ, DOORS, WINDOWS, ETC.) 8. USE ASTM A-615 GRADE 60 REINFORCING STEEL. 9. IN HIGH-LIFT GROUTING USE A MAX. LIFT OF 5'-0" WITH MIN. HALF HOUR MAX. ONE HOUR BETWEEN LIFTS. VIBRATE EACH LIFT AND RECONSOLIDATE PREVIOUS LIFT AFTER PLACING NEXT LIFT. 10. WHERE ANCHOR BOLTS ARE SET IN MASONRY WALL, FILL BLOCK CELLS WITH GROUT FOR BOLTED COURSE, ONE COURSE ABOVE AND TWO COURSES BELOW ANCHOR ELEVATION. 11. CMU CONTROL JOINTS ARE NOT TO EXCEED 24'-0" U.N.O.. THE JOINTS SHALL BE LOCATED A MINIMUM OF 24" FROM DOOR OR WINDOW OPENINGS TO MISS LINTELS U.N.O. THE HORIZONTAL JOINT REINFORCING SHALL BE TERMINATED 2" FROM EACH SIDE OF JOINT. ALL BOND BEAM REINFORCING SHALL CONTINUE THRU THE JOINT. 12. PROVIDE 8" DEEP BOND BEAMS AT 10'-0" O.C. VERTICALLY REINFORCED WITH (2)-#5 CONT, U.N.O.. 1. PREPARE SUBGRADE PER THE RECOMMENDATIONS OUTLINED IN SPECIFICATION SECTION 31 00 00, EARTHWORK. 2. FOR 4" THICK SLABS ON GRADE REINFORCE WITH 6 X 6 - W2.9 X W2.9 WELDED WIRE FABRIC CENTERED IN SLAB, U.N.O. 3. FOR 6" THICK SLABS ON GRADE REINFORCE WITH 6 X 6 - W4.0 X W4.0 WELDED WIRE FABRIC PLACED 2" BELOW TOP OF SLAB, U.N.O. 4. CHAIR WIRE FABRIC DURING CONCRETE PLACEMENT TO INSURE PROPER POSITION IN SLAB. 5. USE 10 MIL POLYETHYLENE SHEETING BETWEEN SOIL AND CONCRETE SLABS. COORDINATE REQUIREMENTS WITH SPECIFICATIONS, U.N.O. 6. PLACE CRACK CONTROL JOINTS AS SHOWN ON PLAN OR AT 12FT MAX (18'- 0" MAX AT 6" SLABS) SO AS TO LIMIT CONCRETE PLACEMENT AREAS TO 144 SQ. FT. MAX. (324 SQ. FT AT 6" SLABS) IN ALL FLOATING SLABS ON GRADE. DO NOT EXCEED A 2 TO 1 WIDTH TO LENGTH RATIO. CONTRACTOR SHALL SUBMIT A CONTROL JOINT LAYOUT FOR ENGINEER'S REVIEW PRIOR TO CONCRETE PLACEMENT. LOCATE CONTROL JOINTS AT COLUMN LINES TYPICAL. 7. RECESS SLABS ON GRADE FOR THICKSET FLOOR TILE FINISHES. 8. PROVIDE 6" CAPILLARY WATER BARRIER UNDER INTERIOR PORTIONS OF SLAB ON GRADE. CAPILLARY WATER BARRIER SHALL CONSIST OF WASHED, NARROWLY GRADED MIXTURE OF CRUSHED STONE, OR CRUSHED OR UNCRUSHED GRAVEL; ASTM D448, COURSE - AGGREGATE GRADING SIZE 57; WITH 100 PERCENT PASSING A 1 1/2" SIEVE AND 0 TO 5 PERCENT PASSING A NO. 8 SIEVE, OR NATURAL SAND WITH A MAXIMUM 10 PERCENT PASSING A NO. 200 SIEVE. CONSULTING GROUP,INC. 901 W. Garden St. Pensacola, FL 32502 P: 850-438-0050 F: 850-432-8631 FLORIDA LICENSE NUMBER 05371 MECHANICAL ELECTRICAL STRUCTURAL COMMUNICATIONS INDUSTRIAL S C H M I D T . SCG PROJECT: 2015-176 STUART SMITH P.E. FLORIDA LICENSE NUMBER 49738 1 A SHEET IDENTIFICATION US Army Corps of Engineers ® Mobile District U.S. ARMY CORPS OF ENGINEERS DESIGNED BY: BULLOCK TICE ASSOCIATES 909 E. CERVANTES STREET, SUITE B. PENSACOLA, FLORIDA 2 3 4 5 B C D DWN BY: SUBMITTED BY: PLOT SCALE: SIZE: CKD BY: PLOT DATE: DATE: SOLICITATION NO.: CONTRACT NO.: PROJECT NUMBER: FILE NAME: MARK DESCRIPTION DATE APPR. MARK DESCRIPTION DATE APPR. 1:1 ANSI D MOBILE DISTRICT MOBILE, ALABAMA M015ES13 FY16 ADDITION TO 39 IOS FACILITY HURLBURT FIELD, FLORIDA W91278-17-R-0010 08 FEB, 2017 S001 STRUCTURAL NOTES S.SMITH J.KELLY S.SMITH S.SMITH FEBRUARY 8, 2017 S001ES13.DWG STRUCTURAL STEEL REINFORCED CONCRETE CONCRETE MASONRY SLABS ON GRADE 12. ALL WINDOWS, DOORS, LOUVERS, SKYLIGHTS, ETC. AND THEIR ATTACHMENTS TO THEIR STRUCTURAL FRAME SHALL BE DESIGNED TO RESIST ALL INTERNATIONAL BUILDING CODE 2012 EDITION, ASCE 7-10, AND UFC 4-010-01 LOAD REQUIREMENTS INCLUDING BUT NOT LIMITED TO WIND LOADS, AND BLAST RESISTANCE. ALL WINDOWS, SKYLIGHTS, ETC. SHALL BE DESIGNED BY THEIR SYSTEMS ENGINEER AND PROVIDED AS A SYSTEM INCLUDING ANY REQUIRED INTERMEDIATE SUPPORT AND THEIR ATTACHMENTS TO THE MAIN STRUCTURAL FRAME. 13. ALL PROPRIETARY SYSTEMS OR ACCESSORIES DESIGNATED IN THESE PLANS AS "OR EQUAL" MAY BE SUBSTITUTED WITH ANOTHER SYSTEM THAT HAS LOAD CAPACITY GREATER THAN OR EQUAL, AND DEFLECTION LESS THAN OR EQUAL TO THE SYSTEM DESIGNATED. APPROVAL SHALL BE REQUESTED FOR ANY SUBSTITUTIONS BY THE ENGINEER OF RECORD THROUGH AN RFI. THE CONTRACTOR SHALL BE HELD FINANCIALLY RESPONSIBLE FOR THE REPLACEMENT OF UNAPPROVED SUBSTITUTIONS WHICH ARE NOT EQUIVALENT TO THE DESIGNATED SYSTEM OR ACCESSORY. 14. ALL PROPRIETARY SYSTEMS AND ACCESSORIES SHALL BE INSTALLED WITH STRICT ADHERENCE TO MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. 15. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS REFERENCES THE FINISHED FLOOR ELEVATION OF THE FIRST FLOOR. REFER TO THE CIVIL DRAWINGS FOR ACTUAL DATUM ELEVATION. 1. THIS PROJECT IS DESIGNED TO COMPLY WITH THE FOLLOWING CRITERIA: - IBC 2012: INTERNATIONAL BUILDING CODE - ASCE 7-10: MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES - UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, 1 JULY 2013 WITH CHANGE 3, 1 AUGUST 2015 - UFC 3-301-01, STRUCTURAL ENGINEERING, 1 JUNE 2013 WITH CHANGE 1, 15 MAY 2014 - UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS, 1 JUNE 2013 - UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 9 FEBRUARY 2012, WITH CHANGE 1, 1 OCTOBER 2013 - UFC 4-010-02, DOD MINIMUM ANTITERRORISM STANDOFF DISTANCE FOR BLDG.'s, 9 FEBRUARY 2012. 2. ALL REFERENCED STANDARDS REFER TO THE EDITION IN FORCE AT THE TIME THESE PLANS AND SPECIFICATIONS ARE ISSUED. 3. REVIEW ALL CONTRACT DOCUMENTS, DIMENSIONS AND SITE CONDITIONS AND COORDINATE WITH FIELD DIMENSIONS AND PROJECT SHOP DRAWINGS PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES IN WRITING TO CONTRACTING OFFICER. DO NOT CHANGE SIZE OR DIMENSIONS OF STRUCTURAL MEMBERS WITHOUT WRITTEN INSTRUCTIONS FROM THE STRUCTURAL ENGINEER OF RECORD. 4. ANY DISCREPANCIES, OMISSIONS OR VARIATIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS DISCOVERED DURING THE BIDDING PERIOD SHALL BE IMMEDIATELY COMMUNICATED IN WRITING TO THE CONTRACTING OFFICER. 5. PROTECT EXISTING FACILITIES, STRUCTURES AND UTILITY LINES FROM ALL DAMAGE. THE CONTRACTOR SHALL PROTECT HIS WORK, ADJACENT PROPERTY AND THE PUBLIC. EACH CONTRACTOR IS SOLELY RESPONSIBLE FOR DAMAGE OR INJURY DUE TO HIS ACT OR NEGLECT. 6. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND SUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 7. DO NOT SCALE DRAWINGS; USE DIMENSIONS. 8. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF OPENINGS IN STRUCTURE NOT SHOWN ON STRUCTURAL DRAWINGS. 9. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS APPLY TO ALL SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETHER OR NOT THEY ARE KEYED IN AT EACH LOCATION. QUESTIONS REGARDING APPLICABILITY OF TYPICAL DETAILS SHALL BE RESOLVED BY THE CONTRACTING OFFICER. 10. ALL WIND FORCES SHALL BE DETERMINED ACCORDING TO ASCE 7-2010 FOR THE MINIMUM WIND CRITERIA STATED BELOW, INCLUDE ALL APPROPRIATE SHAPE, HEIGHT, AND GUST FACTORS FOR THE MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS, AND CLADDING. TO CALCULATE THE MAXIMUM NET ROOF UPLIFT, USE A DEAD LOAD OF 5 PSF. FOR ROOF ATTACHMENTS USE THE LOADS DIRECTLY FROM THE CLADDING DIAGRAM. 16. DESIGN FOR WIND IN ACCORDANCE WITH ASCE 7-10 AND UFC 3-301-01 UNIFIED FACILITIES CRITERIA, STRUCTURAL ENGINEERING, 1 JUNE 2013 WITH CHANGE 1, 15 MAY 2014. FLOOR LIVE LOADS: CLASS ROOMS (ACCESS FLOOR): 100 PSF CONFERENCE ROOMS: 100 PSF RESTROOMS: 75 PSF CORRIDORS (ABOVE FIRST FLOOR): 80 PSF WALKWAYS AND STAIRS: 100 PSF OFFICES: 50 PSF PARTITIONS: 15 PSF MECHANICAL ROOM: 125 PSF LIGHT STORAGE: 125 PSF TRAINING ROOM (ACCESS FLOOR): 100 PSF FLOOR DEAD LOADS: SELF WEIGHT ACTUAL SUPERIMPOSED (MEP) 15 ACCESS FLOOR 10 ROOF LOADS: LIVE LOAD: 20 PSF (REDUCTION ALLOWED) DEAD LOAD: ACTUAL SUPERIMPOSED DEAD LOAD: 15 PSF WIND DESIGN: DESIGN FOR WIND IN ACCORDANCE WITH ASCE 7-10 AND UFC 3-301-01 UNIFIED FACILITIES CRITERIA, STRUCTURAL ENGINEERING, 1 JUNE 2013 WITH CHANGE 1, 15 MAY 2014. WIND VELOCITY (ULTIMATE): 145 MPH WIND VELOCITY (NORMAL): 113 MPH EXPOSURE CATEGORY : 'C' RISK CATEGORY: II ENCLOSURE: ENCLOSED INTERNAL PRESSURE COEFFICIENT: +-0.18 SNOW: GROUND SNOW LOAD: 0 SOILS PROPERTY (FROM GEOTECHNICAL REPORT) DESIGN BEARING PRESSURE = 2000 PSF SEISMIC DESIGN: DESIGN FOR SEISMIC IN ACCORDANCE WITH IBC 2012 AND UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS, 1 JUNE 2013. Ss: 0.08 S1.0: 0.05 RISK CATEGORY: II SITE CLASS: D SEISMIC IMPORTANCE FACTOR: 1.00 Sds: 0.085 Sdi: 0.08 SEISMIC DESIGN CATEGORY: B SEISMIC FORCE RESISTING SYSTEM: STRUCTURAL STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE. SEISMIC DESIGN BASE SHEAR: 0.026W Cs: .026 R: 3.25 ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE METHOD GENERAL NOTES 11. ATFP DESIGN CRITERIA PER UFC 4-010-01 DATED 9 FEBRUARY 2012 WITH CHANGE 1, 1 OCTOBER 2013: BUILDING LOCATION:WITHIN CONTROLLED PERIMETER BUILDING OCCUPANCY CATEGORY: INHABITED / PRIMARY GATHERING WALL TYPE: VENEER AND CMU LOAD BEARING STANDOFF: DISTANCE PROVIDED: 49' STANDOFF EXPLOSIVE WEIGHT: TYPE II BLAST DESIGN: ROOF JOISTS, WINDOWS, WINDOW FRAMES AND CONNECTIONS, DOORS SHALL BE DESIGNED AND DETAILED TO CONFORM TO THE REQUIREMENTS OF THE LATEST UFC 4-010-01 STATED ABOVE.
25
Embed
WITH THE ABOVE REQUIREMENTS. PROVIDE … · electrodes conforming to aws d1.1, e70 series, u.n.o. show all shop welds on the fabrication drawings and all field welds on the erection
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
M) c )) ccPREPARE SUBGRADE PER THE RECOMMENDATIONS OUTLINED IN SPECIFICATION SECTION 31 00 00, EARTHWORK.FOR 4" THICK SLABS ON GRADE REINFORCE WITH 6 X 6 - W2.9 X W2.9 WELDED WIRE FABRIC CENTERED IN SLAB, U.N.O.FOR 6" THICK SLABS ON GRADE REINFORCE WITH 6 X 6 - W4.0 X W4.0 WELDED WIRE FABRIC PLACED 2" BELOW TOP OF SLAB, U.N.O.CHAIR WIRE FABRIC DURING CONCRETE PLACEMENT TO INSURE PROPER POSITION IN SLAB.USE 10 MIL POLYETHYLENE SHEETING BETWEEN SOIL AND CONCRETE SLABS. COORDINATE REQUIREMENTS WITH SPECIFICATIONS, U.N.O.PLACE CRACK CONTROL JOINTS AS SHOWN ON PLAN OR AT 12FT MAX
(18'- 0" MAX AT 6" SLABS) SO AS TO LIMIT CONCRETE PLACEMENT AREAS TO 144 SQ. FT. MAX. (324 SQ. FT AT 6" SLABS) IN ALL FLOATING SLABS ON GRADE. DO NOT EXCEED A 2 TO 1 WIDTH TO LENGTH RATIO.CONTRACTOR SHALL SUBMIT A CONTROL JOINT LAYOUT FOR ENGINEER'S REVIEW PRIOR TO CONCRETE PLACEMENT. LOCATE CONTROL JOINTS AT COLUMN LINES TYPICAL.RECESS SLABS ON GRADE FOR THICKSET FLOOR TILE FINISHES.PROVIDE 6" CAPILLARY WATER BARRIER UNDER INTERIOR PORTIONS OF SLAB ON GRADE. CAPILLARY WATER BARRIER SHALL CONSIST OF WASHED, NARROWLY GRADED MIXTURE OF CRUSHED STONE, OR CRUSHED OR UNCRUSHED GRAVEL; ASTM D448, COURSE - AGGREGATE GRADING SIZE 57; WITH 100 PERCENT PASSING A 1 1/2" SIEVE AND 0 TO 5 PERCENT PASSING A NO. 8 SIEVE, OR NATURAL SAND WITH A MAXIMUM 10 PERCENT PASSING A NO. 200 SIEVE.
FLORIDA LICENSE NUMBER 05371 901 W Garden St Pensacola, FL 325
P 850-438-0050 F 850-432-8631
- UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS, 1 JUNE 2013- UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 9
FEBRUARY 2012, WITH CHANGE 1, 1 OCTOBER 2013- UFC 4-010-02, DOD MINIMUM ANTITERRORISM STANDOFF DISTANCE FOR BLDG.'s,
9 FEBRUARY 2012.2. ALL REFERENCED STANDARDS REFER TO THE EDITION IN FORCE AT THE TIME
THESE PLANS AND SPECIFICATIONS ARE ISSUED.3. REVIEW ALL CONTRACT DOCUMENTS, DIMENSIONS AND SITE CONDITIONS AND
COORDINATE WITH FIELD DIMENSIONS AND PROJECT SHOP DRAWINGS PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES IN WRITING TO CONTRACTING OFFICER. DO NOT CHANGE SIZE OR DIMENSIONS OF STRUCTURAL MEMBERS WITHOUT WRITTEN INSTRUCTIONS FROM THE STRUCTURAL ENGINEER OF RECORD.
4. ANY DISCREPANCIES, OMISSIONS OR VARIATIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS DISCOVERED DURING THE BIDDING PERIOD SHALL BE IMMEDIATELY COMMUNICATED IN WRITING TO THE CONTRACTING OFFICER.
5. PROTECT EXISTING FACILITIES, STRUCTURES AND UTILITY LINES FROM ALL DAMAGE. THE CONTRACTOR SHALL PROTECT HIS WORK, ADJACENT PROPERTY AND THE PUBLIC. EACH CONTRACTOR IS SOLELY RESPONSIBLE FOR DAMAGE OR INJURY DUE TO HIS ACT OR NEGLECT.
6. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND SUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
7. DO NOT SCALE DRAWINGS; USE DIMENSIONS.8. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF
OPENINGS IN STRUCTURE NOT SHOWN ON STRUCTURAL DRAWINGS.9. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS APPLY TO ALL
SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETHER OR NOT THEY ARE KEYED IN AT EACH LOCATION. QUESTIONS REGARDING APPLICABILITY OF TYPICAL DETAILS SHALL BE RESOLVED BY THE CONTRACTING OFFICER.
10. ALL WIND FORCES SHALL BE DETERMINED ACCORDING TO ASCE 7-2010 FOR THE MINIMUM WIND CRITERIA STATED BELOW, INCLUDE ALL APPROPRIATE SHAPE, HEIGHT, AND GUST FACTORS FOR THE MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS, AND CLADDING. TO CALCULATE THE MAXIMUM NET ROOF UPLIFT, USE A DEAD LOAD OF 5 PSF. FOR ROOF ATTACHMENTS USE THE LOADS DIRECTLY FROM THE CLADDING DIAGRAM.
)c
c )
PROVIDE CURRENT (MAX 1 YEAR OLD) STATISTICAL DATA FOR EACH CONCRETE MIX DESIGN SUBMITTED.WHERE CONCENTRATION OF REINFORCING STEEL HINDERS PROPER CONSOLIDATION OF CONCRETE USE CONCRETE CONTAINING A SUPERPLASTICIZING (N.R.W.R.)ADMIXTURE, ASTM C494 TYPE F. SLUMP AFTER ADDITION OF SUPERPLASTICIZER SHALL BE 9"±1".IF CONCRETE IS PUMPED, SLUMP MAY BE INCREASED TO 6" AT THE TRUCK, PROVIDED THE SLUMP SPECIFIED IN NOTE 2 IS MAINTAINED AT THE DISCHARGE END.USE A MINIMUM 4- INCH PUMP, UNLESS PRE-APPROVED BY THE ARCHITECT. TAKE CONCRETE SAMPLES FOR SLUMP AT TRUCK AND AT DISCHARGE END. TAKE CONCRETE SAMPLES FOR CYLINDER TESTING AT DISCHARGE END.USE ASTM A-615 GR. 60 FOR ALL REINFORCING STEEL, CONFORM TO ACI-301, ACI-315, ACI-318, AND CRSI "MANUAL OF STANDARD PRACTICE:. ALL REINFORCING SHALL BE ACCURATELY PLACED, RIGIDLY SUPPORTED AND FIRMLY TIED IN PLACE WITH BAR SUPPORTS AND SPACERS IN ACCORDANCE WITH THE ABOVE REQUIREMENTS. PROVIDE CLASS B LAP SPLICE FOR CONTINUOUS BARS, U.N.O. LAP BOTTOM STEEL OVER SUPPORTS AND TOP STEEL AT MIDSPAN UNLESS OTHERWISE SPECIFIED. HOOK DISCONTINUOUS ENDS OF ALL TOP BARS AND ALL BARS IN WALLS, U.N.O. USE 1" COVER OVER REINFORCING EXCEPT AS FOLLOWS:
12. ALL WINDOWS, DOORS, LOUVERS, SKYLIGHTS, ETC. AND THEIR ATTACHMENTS TO THEIR STRUCTURAL FRAME SHALL BE DESIGNED TO RESIST ALL INTERNATIONAL BUILDING CODE 2012 EDITION, ASCE 7-10, AND UFC 4-010-01 LOAD REQUIREMENTS INCLUDING BUT NOT LIMITED TO WIND LOADS, AND BLAST RESISTANCE. ALL WINDOWS, SKYLIGHTS, ETC. SHALL BE DESIGNED BY THEIR SYSTEMS ENGINEER AND PROVIDED AS A SYSTEM INCLUDING ANY REQUIRED INTERMEDIATE SUPPORT AND THEIR ATTACHMENTS TO THE MAIN STRUCTURAL FRAME.
13. ALL PROPRIETARY SYSTEMS OR ACCESSORIES DESIGNATED IN THESE PLANS AS "OR EQUAL" MAY BE SUBSTITUTED WITH ANOTHER SYSTEM THAT HAS LOAD CAPACITY GREATER THAN OR EQUAL, AND DEFLECTION LESS THAN OR EQUAL TO THE SYSTEM DESIGNATED. APPROVAL SHALL BE REQUESTED FOR ANY SUBSTITUTIONS BY THE ENGINEER OF RECORD THROUGH AN RFI. THE CONTRACTOR SHALL BE HELD FINANCIALLY RESPONSIBLE FOR THE REPLACEMENT OF UNAPPROVED SUBSTITUTIONS WHICH ARE NOT EQUIVALENT TO THE DESIGNATED SYSTEM OR ACCESSORY.
14. ALL PROPRIETARY SYSTEMS AND ACCESSORIES SHALL BE INSTALLED WITH STRICT ADHERENCE TO MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS.
15. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS REFERENCES THE FINISHED FLOOR ELEVATION OF THE FIRST FLOOR. REFER TO THE CIVIL DRAWINGS FOR ACTUAL DATUM ELEVATION.
NOTE: * = 2" FOR #6 BARS AND LARGER. 1-1/2" FOR #5 BARS AND SIMILAR.USE PLAIN, COLD-DRAWN, ELECTRICALLY WELDED, STEEL WIRE FABRIC CONFORMING TO ASTM A-185. SUPPLY IN FLAT SHEETS ONLY. LAP SPLICES SHALL BE MEASURED BETWEEN OUTERMOST CROSS WIRES OF EACH FABRIC SHEET AND SHALL BE NOT LESS THAN TWICE THE SPACING OF THE CROSS WIRES PLUS TWO (2) INCHESTHE GROUND FLOOR SLAB SHALL BE UNDERLAIN BY A MINIMUM 10 MIL.VAPOR RETARDER ON 6" MINIMUM CLEAN SAND CAPILLARY BARRIER.SLEEVE ALL PIPES THRU SLABS ON GRADE INDIVIDUALLY. OPENINGS LARGER THAN 6", NOT SHOWN ON STRUCTURAL DRAWINGS, SHALL REQUIRE SHOP DRAWINGS SHOWING SIZE AND LOCATION FOR COTR APPROVAL. PROVIDE (1)-#5x4'-0" E.W. PLACED DIAGONALLY AT MID DEPTH AROUND ALL OPENINGS LARGER THAN 12" UNLESS OTHERWISE NOTED ON DRAWINGS. NO CONDUIT SHALL BE EMBEDDED IN SLAB WITHOUT PRIOR APPROVAL FROM THE CONTRACTING OFFICER.SUBMIT SHOP DRAWINGS FOR ALL REINFORCING STEEL TO COTR FOR APPROVAL PRIOR TO FABRICATION.
Vma
rk
|
^ddvl
I SIZ
E:I A
NSI
D
I PLO
T SC
ALE
:
(DES
IGNE
D B
Y:
I S.S
MIT
H
1. ALL STEEL WORK (INCLUDING FABRICATION AND ERECTION) SHALLCONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION 14THEDITION AND PROJECT SPECIFICATIONS, USE THE FOLLOWING:
A. ROLLED SHAPES, ASTM A992, GRADE 50. B. PLATES BARS A36. C. COLD-FORMED STEEL TUBING: ASTM A500, GRADE B. D. HOT-FORMED STEEL TUBING: ASTM A501. E. STEEL PIPE: ASTM A53, TYPE E OR S, GRADE B.2. USE STRUCTURAL STEEL THAT IS FULLY WELDABLE WITHIN GRADES
AND FROM ANY GRADE TO ANY OTHER GRADE. WELD ALL SHOPCONNECTIONS, U.N.O.
3. ALL SHOP AND FIELD WELDING SHALL CONFORM TO THESTRUCTURAL WELDING CODE AWS D1.1, LATEST EDITION,PUBLISHED BY THE AMERICAN WELDING SOCIETY (AWS). USEELECTRODES CONFORMING TO AWS D1.1, E70 SERIES, U.N.O.SHOW ALL SHOP WELDS ON THE FABRICATION DRAWINGS AND ALLFIELD WELDS ON THE ERECTION DRAWINGS.
4. ALL SHOP AND FIELD WELDERS, WELDING OPERATORS, ANDTACKERS SHALL BE CERTIFIED ACCORDING TO AWS PROCEDURESFOR THE WELDING PROCESS AND WELDING POSITION USED.
5. ALL JOINT WELDING PROCEDURES TO BE USED SHALL BEPREPARED BY THE FABRICATOR OR CONTRACTOR AS WRITTENPROCEDURE SPECIFICATIONS AND SUBMITTED TO THECONTRACTING OFFICER FOR THEIR RECORD. ALL JOINT WELDINGPROCEDURES SHALL BE QUALIFIED PRIOR TO USE ACCORDING TOAWS PROCEDURES.
6. A325 BOLTS: A. A325 BOLTS SHALL CONFORM TO ASTM A 325 TYPE 1, HIGH STRENGTH BOLTS FOR STRUCTURAL STEEL JOINTS. DO NOT USE TYPE 2 BOLTS. B. PROVIDE HARDENED WASHERS CONFORMING TO ASTM F 436.
PLACE HARDENED WASHERS UNDER PART BEING TURNED. C. LOAD INDICATOR WASHERS OR BOLTS SHALL BE USED ON ALL A325 BOLTS. D. ALL BOLTS SHALL BE NEW AND DOMESTICALLY MANUFACTURED. DO NOT REUSE BOLTS. USE ONLY NON-GALVANIZED NUTS AND BOLTS THAT ARE CLEAN, RUST-FREE, AND WELL LUBRICATED.7. USE F1554 BOLTS FOR ANCHOR BOLTS OR WHEN SPECIFICALLY
CALLED FOR ON THE DRAWINGS.8. CUT, DRILL, OR PUNCH HOLES PERPENDICULAR TO METAL SURFACES.
DO NOT FLAME CUT HOLES OR ENLARGE HOLES BY BURNING.9. SPLICING OF STRUCTURAL STEEL MEMBERS IN THE FIELD OR IN THE
SHOP IS PROHIBITED EXCEPT WHERE INCLUDED ON THE DRAWINGS.10. DO NOT PAINT STEEL SURFACES IN CONTACT WITH CONCRETE. DO
NOT APPLY FINISH COAT AND LIMIT PRIME COAT TO 2 MILS ATFAYING SURFACES OF SLIP CRITICAL BOLTED CONNECTIONS,SURFACES TO BE WELDED AND TOP SURFACES OF BEAMS ANDTRUSSES TO RECEIVE STEEL STUDS AND/OR SUPPORTING METALFLOOR AND ROOF DECKING. USE PRIMER WHICH HAS A MIN. CLASSA SLIP COEFFICIENT (0.33).
11. REFER TO SPECIFICATIONS FOR PAINTING OF STRUCTURAL STEEL12. SUBMIT STRUCTURAL STEEL SHOP DRAWINGS TO COTR
FOR REVIEW BEFORE FABRICATION.13. PROVIDE TEMPORARY BRACING AS NECESSARY TO INSURE A STABLE
STRUCTURE DURING CONSTRUCTION.14. DO NOT REPRODUCE THE STRUCTURAL DRAWINGS FOR USE AS SHOP
DRAWINGS.15. NO CUTTING OF SECTIONS, FLANGES, WEBS OR ANGLES SHALL BE
ALLOWED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OFRECORD.
16. ALL EXPOSED STEEL MEMBERS & CONNECTIONS SHALL BE HOT DIP GALVANIZED PRIOR TO FABRICATION. ALL CONNECTIONS SHALL BE PRE DRILLED AND/OR WELDED PRIOR TO HOT DIP GALVANIZING.17. SLIP CRITICAL JOINTS SHALL HAVE CLASS A FAYING SURFACES WITH SLIP CHECKED AT THE FACTORED LOAD LEVEL.
1. USE STRUCTURAL CONCRETE AND CONCRETING PRACTICES CONFORMINGTO ACI-301, ACI-318, AND PROPORTION CONCRETE IN ACCORDANCE WITHACI-318 CH. 4 AND MEETING A MINIMUM ULTIMATE COMPRESSIVE STRENGTHIN 28 DAYS AS FOLLOWS:
-FOOTINGS 4000 PSI-SLABS ON GRADE 4000 PSI-ALL OTHER CONCRETE 4000 PSI
PROVIDE CURRENT (MAX 1 YEAR OLD) STATISTICAL DATA FOR EACHCONCRETE MIX DESIGN SUBMITTED.
2. WHERE CONCENTRATION OF REINFORCING STEEL HINDERS PROPERCONSOLIDATION OF CONCRETE USE CONCRETE CONTAINING ASUPERPLASTICIZING (N.R.W.R.)ADMIXTURE, ASTM C494 TYPE F. SLUMPAFTER ADDITION OF SUPERPLASTICIZER SHALL BE 9"±1".
3. IF CONCRETE IS PUMPED, SLUMP MAY BE INCREASED TO 6" AT THE TRUCK,PROVIDED THE SLUMP SPECIFIED IN NOTE 2 IS MAINTAINED AT THEDISCHARGE END.USE A MINIMUM 4- INCH PUMP, UNLESS PRE-APPROVED BYTHE ARCHITECT. TAKE CONCRETE SAMPLES FOR SLUMP AT TRUCK AND ATDISCHARGE END. TAKE CONCRETE SAMPLES FOR CYLINDER TESTING ATDISCHARGE END.
4. USE ASTM A-615 GR. 60 FOR ALL REINFORCING STEEL, CONFORM TO ACI-301, ACI-315, ACI-318, AND CRSI "MANUAL OF STANDARD PRACTICE:. ALLREINFORCING SHALL BE ACCURATELY PLACED, RIGIDLY SUPPORTED ANDFIRMLY TIED IN PLACE WITH BAR SUPPORTS AND SPACERS IN ACCORDANCEWITH THE ABOVE REQUIREMENTS. PROVIDE CLASS B LAP SPLICE FORCONTINUOUS BARS, U.N.O. LAP BOTTOM STEEL OVER SUPPORTS AND TOPSTEEL AT MIDSPAN UNLESS OTHERWISE SPECIFIED. HOOK DISCONTINUOUSENDS OF ALL TOP BARS AND ALL BARS IN WALLS, U.N.O. USE 1" COVER OVERREINFORCING EXCEPT AS FOLLOWS:
BOTTOM TOP SIDESFOOTINGS 3" 2" 3"SLABS ON GRADE 2" 1" 2"POURED WALLS RETAINING FILL - - 2" *POURED WALLS ABOVE GROUND - - 3/4"
NOTE: * = 2" FOR #6 BARS AND LARGER. 1-1/2" FOR #5 BARS AND SIMILAR.5. USE PLAIN, COLD-DRAWN, ELECTRICALLY WELDED, STEEL WIRE FABRIC
CONFORMING TO ASTM A-185. SUPPLY IN FLAT SHEETS ONLY. LAP SPLICESSHALL BE MEASURED BETWEEN OUTERMOST CROSS WIRES OF EACH FABRICSHEET AND SHALL BE NOT LESS THAN TWICE THE SPACING OF THE CROSSWIRES PLUS TWO (2) INCHES
6. THE GROUND FLOOR SLAB SHALL BE UNDERLAIN BY A MINIMUM 10 MIL.VAPOR RETARDER ON 6" MINIMUM CLEAN SAND CAPILLARY BARRIER.
7. SLEEVE ALL PIPES THRU SLABS ON GRADE INDIVIDUALLY. OPENINGS LARGERTHAN 6", NOT SHOWN ON STRUCTURAL DRAWINGS, SHALL REQUIRE SHOP DRAWINGSSHOWING SIZE AND LOCATION FOR COTR APPROVAL. PROVIDE (1)-#5x4'-0" E.W. PLACEDDIAGONALLY AT MID DEPTH AROUND ALL OPENINGS LARGER THAN 12" UNLESSOTHERWISE NOTED ON DRAWINGS. NO CONDUIT SHALL BE EMBEDDED IN SLABWITHOUT PRIOR APPROVAL FROM THE CONTRACTING OFFICER.
8. SUBMIT SHOP DRAWINGS FOR ALL REINFORCING STEEL TO COTR FOR APPROVAL PRIORTO FABRICATION.
1. ALL MASONRY WORK IS TO CONFORM TO ACI 530 AND 530.1.2. CONSTRUCT REINFORCED MASONRY AS NOTED ON THE PLANS AND DETAILS
IN ACCORDANCE WITH THE REQUIREMENTS OF MASONRY SPECIFICATIONSECTIONS. UNREINFORCED MASONRY SHALL NOT BE USED.
3. USE CONCRETE MASONRY UNITS CONFORMING TO ASTM C90. PROVIDE f'mOF 1500 PSI (UNIT STRENGTH 1900 PSI) FOR ALL REINFORCED MASONRYSHEAR WALLS. PERFORM f'm AND C90 COMPLIANCE BY UNIT STRENGTH METHOD.
4. USE TYPE "S" MORTAR IN ACCORDANCE WITH ASTM C270. USE 3/8"FULL-BEDDED JOINTS FOR ALL MASONRY UNITS. REMOVE MORTARPROTRUDING INTO CELL CAVITIES THAT ARE TO BE REINFORCED ANDGROUTED. ALLOW A MIN. OF 24 HOURS FOR MORTAR TO CURE BEFOREPLACING GROUT.
5. USE ALL GROUT CONFORMING TO ASTM C-476 WITH A MIN. COMPRESSIVESTRENGTH OF 3000 PSI IN 28 DAYS, TESTED IN ACCORDANCE WITH ASTMC1019. AGGREGATE TO CONFORM TO ASTM C404 FOR COARSE GROUT ANDSLUMP OF 8" TO 11". TEST SAMPLES FOR COMPRESSIVE STRENGTH. TESTEVERY 30 YARDS OR EACH DAY'S GROUTING.
6. FOR REINFORCED MASONRY USE HEAVY DUTY (3/16" SIDE RODS WITH 9GAUGE CROSS RODS) LADDER TYPE HORIZONTAL JOINT REINFORCING INEVERY OTHER COURSE U.N.O. USE PREFABRICATED CORNERS AND TEES ATWALL INTERSECTIONS. OVERLAP DISCONTINUOUS ENDS A MIN. OF 12".HORIZONTAL REINFORCING SHALL CONFORM TO ASTM A-82.
7. FOR MASONRY CAVITY WALLS, HORIZONTAL JOINT REINFORCING SHALL BEHEAVY DUTY (3/16" SIDE RODS WITH 9 GAUGE CROSS RODS) LADDERTYPE. VERTICAL SPACING OF REINFORCING SHALL BE 16" O.C. MAX. WITH8" O.C. MAX AT BUILDING CORNERS (SEE WIND CLADDING DIAGRAM FORCORNER DIMENSION) TIES SHALL BE LOCATED WITHIN 8" OF WALLDISCONTINUITIES (MCJ, DOORS, WINDOWS, ETC.)
8. USE ASTM A-615 GRADE 60 REINFORCING STEEL.9. IN HIGH-LIFT GROUTING USE A MAX. LIFT OF 5'-0" WITH MIN. HALF HOUR
MAX. ONE HOUR BETWEEN LIFTS. VIBRATE EACH LIFT AND RECONSOLIDATEPREVIOUS LIFT AFTER PLACING NEXT LIFT.
10. WHERE ANCHOR BOLTS ARE SET IN MASONRY WALL, FILL BLOCK CELLSWITH GROUT FOR BOLTED COURSE, ONE COURSE ABOVE AND TWOCOURSES BELOW ANCHOR ELEVATION.
11. CMU CONTROL JOINTS ARE NOT TO EXCEED 24'-0" U.N.O.. THE JOINTSSHALL BE LOCATED A MINIMUM OF 24" FROM DOOR OR WINDOWOPENINGS TO MISS LINTELS U.N.O. THE HORIZONTAL JOINT REINFORCINGSHALL BE TERMINATED 2" FROM EACH SIDE OF JOINT. ALL BOND BEAMREINFORCING SHALL CONTINUE THRU THE JOINT.
12. PROVIDE 8" DEEP BOND BEAMS AT 10'-0" O.C. VERTICALLY REINFORCEDWITH (2)-#5 CONT, U.N.O..
1. PREPARE SUBGRADE PER THE RECOMMENDATIONS OUTLINED INSPECIFICATION SECTION 31 00 00, EARTHWORK.
2. FOR 4" THICK SLABS ON GRADE REINFORCE WITH 6 X 6 - W2.9 X W2.9WELDED WIRE FABRIC CENTERED IN SLAB, U.N.O.
3. FOR 6" THICK SLABS ON GRADE REINFORCE WITH 6 X 6 - W4.0 X W4.0WELDED WIRE FABRIC PLACED 2" BELOW TOP OF SLAB, U.N.O.
4. CHAIR WIRE FABRIC DURING CONCRETE PLACEMENT TO INSUREPROPER POSITION IN SLAB.
5. USE 10 MIL POLYETHYLENE SHEETING BETWEEN SOIL AND CONCRETESLABS. COORDINATE REQUIREMENTS WITH SPECIFICATIONS, U.N.O.
6. PLACE CRACK CONTROL JOINTS AS SHOWN ON PLAN OR AT 12FT MAX (18'- 0" MAX AT 6" SLABS) SO AS TO LIMIT CONCRETE PLACEMENT AREASTO 144 SQ. FT. MAX. (324 SQ. FT AT 6" SLABS) IN ALL FLOATING SLABS ONGRADE. DO NOT EXCEED A 2 TO 1 WIDTH TO LENGTH RATIO.CONTRACTOR SHALL SUBMIT A CONTROL JOINT LAYOUT FOR ENGINEER'SREVIEW PRIOR TO CONCRETE PLACEMENT. LOCATE CONTROL JOINTS ATCOLUMN LINES TYPICAL.
7. RECESS SLABS ON GRADE FOR THICKSET FLOOR TILE FINISHES.8. PROVIDE 6" CAPILLARY WATER BARRIER UNDER INTERIOR PORTIONS OF
SLAB ON GRADE. CAPILLARY WATER BARRIER SHALL CONSIST OF WASHED,NARROWLY GRADED MIXTURE OF CRUSHED STONE, OR CRUSHED ORUNCRUSHED GRAVEL; ASTM D448, COURSE - AGGREGATE GRADING SIZE 57;WITH 100 PERCENT PASSING A 1 1/2" SIEVE AND 0 TO 5 PERCENT PASSING ANO. 8 SIEVE, OR NATURAL SAND WITH A MAXIMUM 10 PERCENT PASSING ANO. 200 SIEVE.
CONSULTING GROUP,INC.
901 W. Garden St. Pensacola, FL 32502P: 850-438-0050 F: 850-432-8631
12. ALL WINDOWS, DOORS, LOUVERS, SKYLIGHTS, ETC. AND THEIR ATTACHMENTSTO THEIR STRUCTURAL FRAME SHALL BE DESIGNED TO RESIST ALLINTERNATIONAL BUILDING CODE 2012 EDITION, ASCE 7-10, AND UFC 4-010-01LOAD REQUIREMENTS INCLUDING BUT NOT LIMITED TO WIND LOADS, AND BLASTRESISTANCE. ALL WINDOWS, SKYLIGHTS, ETC. SHALL BE DESIGNED BY THEIRSYSTEMS ENGINEER AND PROVIDED AS A SYSTEM INCLUDING ANY REQUIREDINTERMEDIATE SUPPORT AND THEIR ATTACHMENTS TO THE MAIN STRUCTURALFRAME.
13. ALL PROPRIETARY SYSTEMS OR ACCESSORIES DESIGNATED IN THESE PLANSAS "OR EQUAL" MAY BE SUBSTITUTED WITH ANOTHER SYSTEM THAT HAS LOADCAPACITY GREATER THAN OR EQUAL, AND DEFLECTION LESS THAN OR EQUALTO THE SYSTEM DESIGNATED. APPROVAL SHALL BE REQUESTED FOR ANYSUBSTITUTIONS BY THE ENGINEER OF RECORD THROUGH AN RFI. THECONTRACTOR SHALL BE HELD FINANCIALLY RESPONSIBLE FOR THEREPLACEMENT OF UNAPPROVED SUBSTITUTIONS WHICH ARE NOT EQUIVALENTTO THE DESIGNATED SYSTEM OR ACCESSORY.
14. ALL PROPRIETARY SYSTEMS AND ACCESSORIES SHALL BE INSTALLED WITHSTRICT ADHERENCE TO MANUFACTURERS INSTRUCTIONS ANDRECOMMENDATIONS.
15. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS REFERENCESTHE FINISHED FLOOR ELEVATION OF THE FIRST FLOOR. REFER TO THE CIVILDRAWINGS FOR ACTUAL DATUM ELEVATION.
1. THIS PROJECT IS DESIGNED TO COMPLY WITH THE FOLLOWING CRITERIA:- IBC 2012: INTERNATIONAL BUILDING CODE- ASCE 7-10: MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES- UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, 1 JULY 2013 WITH CHANGE 3,
1 AUGUST 2015- UFC 3-301-01, STRUCTURAL ENGINEERING, 1 JUNE 2013 WITH CHANGE 1, 15 MAY
2014- UFC 3-310-04 SEISMIC DESIGN FOR BUILDINGS, 1 JUNE 2013- UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 9
FEBRUARY 2012, WITH CHANGE 1, 1 OCTOBER 2013- UFC 4-010-02, DOD MINIMUM ANTITERRORISM STANDOFF DISTANCE FOR BLDG.'s,
9 FEBRUARY 2012.2. ALL REFERENCED STANDARDS REFER TO THE EDITION IN FORCE AT THE TIME
THESE PLANS AND SPECIFICATIONS ARE ISSUED.3. REVIEW ALL CONTRACT DOCUMENTS, DIMENSIONS AND SITE CONDITIONS AND
COORDINATE WITH FIELD DIMENSIONS AND PROJECT SHOP DRAWINGS PRIORTO CONSTRUCTION. REPORT ANY DISCREPANCIES IN WRITING TOCONTRACTING OFFICER. DO NOT CHANGE SIZE OR DIMENSIONS OFSTRUCTURAL MEMBERS WITHOUT WRITTEN INSTRUCTIONS FROM THESTRUCTURAL ENGINEER OF RECORD.
4. ANY DISCREPANCIES, OMISSIONS OR VARIATIONS NOTED ON THE DRAWINGSOR IN THE SPECIFICATIONS DISCOVERED DURING THE BIDDING PERIOD SHALLBE IMMEDIATELY COMMUNICATED IN WRITING TO THE CONTRACTING OFFICER.
5. PROTECT EXISTING FACILITIES, STRUCTURES AND UTILITY LINES FROM ALLDAMAGE. THE CONTRACTOR SHALL PROTECT HIS WORK, ADJACENT PROPERTYAND THE PUBLIC. EACH CONTRACTOR IS SOLELY RESPONSIBLE FOR DAMAGEOR INJURY DUE TO HIS ACT OR NEGLECT.
6. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, ANDSUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THECONTRACTOR.
7. DO NOT SCALE DRAWINGS; USE DIMENSIONS.8. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF
OPENINGS IN STRUCTURE NOT SHOWN ON STRUCTURAL DRAWINGS.9. DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS APPLY TO ALL
SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLYDETAILED. SUCH DETAILS APPLY WHETHER OR NOT THEY ARE KEYED IN ATEACH LOCATION. QUESTIONS REGARDING APPLICABILITY OF TYPICAL DETAILSSHALL BE RESOLVED BY THE CONTRACTING OFFICER.
10. ALL WIND FORCES SHALL BE DETERMINED ACCORDING TO ASCE 7-2010 FORTHE MINIMUM WIND CRITERIA STATED BELOW, INCLUDE ALL APPROPRIATESHAPE, HEIGHT, AND GUST FACTORS FOR THE MAIN WIND FORCE RESISTINGSYSTEM, COMPONENTS, AND CLADDING. TO CALCULATE THE MAXIMUM NETROOF UPLIFT, USE A DEAD LOAD OF 5 PSF. FOR ROOF ATTACHMENTS USE THELOADS DIRECTLY FROM THE CLADDING DIAGRAM.
16. DESIGN FOR WIND IN ACCORDANCE WITH ASCE 7-10AND UFC 3-301-01 UNIFIED FACILITIES CRITERIA,STRUCTURAL ENGINEERING, 1 JUNE 2013 WITHCHANGE 1, 15 MAY 2014.FLOOR LIVE LOADS:
CLASS ROOMS (ACCESS FLOOR): 100 PSFCONFERENCE ROOMS: 100 PSFRESTROOMS: 75 PSFCORRIDORS (ABOVE FIRST FLOOR):
WIND DESIGN:DESIGN FOR WIND IN ACCORDANCE WITH ASCE 7-10AND UFC 3-301-01 UNIFIED FACILITIES CRITERIA,STRUCTURAL ENGINEERING, 1 JUNE 2013 WITHCHANGE 1, 15 MAY 2014.
FLORIDA LICENSE NUMBER 05371 901 W Garden St Pensacola, FL 325
P 850-438-0050 F 850-432-8631
c )FOUNDATION DESIGN IS BASED ON AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 POUNDS PER SQUARE FOOT BY THE GEOTECHNICAL REPORT PREPARED BY THE U.S.ARMY CORPS OF ENGINEERS (USACE) MOBILE DISTRICT APRIL 2016.GENERAL: EXISTING VEGETATED AREAS TO RECEIVE FILL SHALL BE STRIPPED OF ALL SURFACE VEGETATION AND TOPSOIL. TOPSOIL SUITABLE FOR REUSE SHALL BE STOCKPILED FOR REUSE. IF TOPSOIL IS REUSED, IT MAY REQUIRE FURTHER SOIL AMENDMENTS BEFORE IT IS SUITABLE. THE CONTRACTOR SHALL REFER TO RELEVANT SPECIFICATIONS FOR FURTHER GUIDANCE. PROVISIONS SHALL BE MADE TO MAINTAIN ALL EXCAVATIONS FREE OF SURFACE WATER.DEMOLITION: WHERE SURROUNDING PAVEMENTS AND STRUCTURES ARE DEMOLISHED TO MAKE WAY FOR NEW CONSTRUCTION, BURIED COMPONENTS SHALL BE COMPLETELY REMOVED. ANY RESULTING VOIDS SHALL BE BACKFILLED AND COMPACTED WITH SATISFACTORY SOILS. IF THERE ARE ANY UTILITY LINES THAT ARE TO BE REMOVED AND ARE TOO DEEP FOR PROPER EXCAVATION, THEY MAY BE GROUTED IN PLACE AFTER APPROVAL IS RECEIVED FROM BOTH THE CONTRACTING OFFICER AND THE USACE MOBILE DISTRICT OFFICE.DEWATERING: THE WATER TABLE ENCOUNTERED DURING THE SUBSURFACE INVESTIGATIONS IS AT A STATIC DEPTH OF 15 FEET AND MAY AFFECT THE CONSTRUCTION OF THE FOUNDATION SYSTEM. DEWATERING WILL BE NECESSARY FOR UTILITY CONSTRUCTION, UNDERCUTTING, AND RE-COMPACTION FOR STRUCTURAL FOOTINGS. BACKFILL SHALL BE PLACED IMMEDIATELY AS EXCAVATION PROGRESSES.UNDERCUTTING FOR FOUNDATIONS: THE SOIL WITHIN 2.0 FEET OF THE BOTTOM OF ALL FOOTINGS SHALL BE UNDERCUT AND BACKFILLED WITH AN ENGINEERED FILL. IT IS ANTICIPATED THAT THE IN-SITU MATERIAL USED DURING CONSTRUCTION WILL BE CLASSIFIED AS SATISFACTORY AND REQUIRE ONLY DENSIFICATION VIA COMPACTION.THE NEW CONSTRUCTION IS ADJACENT TO THE EXISTING 39TH IOS BUILDING (B90074) AND MAY INFLUENCE THE FOUNDATIONS SYSTEM OF THIS BUILDING. THERE SHALL NOT BE EXTENSIVE UNDERCUTTING NEXT TO THIS BUILDING. ONLY LIMITED UNDERCUTTING AND RE-COMPACTION IS ALLOWED FOR ISOLATED REMOVAL OF UNSATISFACTORY MATERIALS OR FILLING VOIDS DUE TO UTILITY REMOVAL. FILL AND SUBGRADE COMPACTION FOR NEW FOOTINGS ADJACENT TO THE EXISTING BUILDING (WITHIN 5.0 FEET) SHALL BE COMPACTED WITH HAND COMPACTORS IN 4" LOOSE LIFTS. ROLLER COMPACTION MAY NOT BE USED WITHIN 5.0 FEET OF THE EXISTING 39TH IOS BUILDING. LARGE VIBRATORY EQUIPMENT WILL NOT BE USED FOR THIS PROJECT.FOUNDATION RECOMMENDATIONS: THE NATIVE MATERIAL AT THE PROJECT SITE IS ANTICIPATED TO BE SATISFACTORY FOR RE-COMPACTION. WHERE THE SUBGRADE APPEARS TO BE UNSATISFACTORY IT SHALL BE UNDERCUT AND RE-COMPACTED. WHERE THE GRADE REQUIRES ADDITIONAL FILL IT SHALL BE CONSISTENT WITH THE NATIVE, SATISFACTORY MATERIAL; POORLY GRADED FINE-GRAINED SAND. ALL COMPACTED MATERIAL SHALL BE PLACED IN 8" LOOSE LIFTS FOR HEAVY COMPACTION EQUIPMENT. HAND COMPACTION SHALL BE DONE IN 4" LOOSE LIFTS. TWO FEET OF UNDERCUTTING AND RE-COMPACTION IS REQUIRED FOR FOOTINGS 10.0 FEET AWAY FROM THE EXISTING BUILDING. DURING CONSTRUCTION, ALL SOIL IMPROVEMENT WITHIN 5.0 FEET OF THE EXISTING FOOTINGS SHALL BE PERFORMED BY HAND COMPACTION IN 4" LOOSE LIFTS. ALL EXCAVATIONS SHALL BE MADE WITH THE INTENT TO EXECUTE THE REQUIRED CONSTRUCTION AND BACKFILL AS QUICKLY AS POSSIBLE. LARGE EXCAVATIONS SHALL NOT BE OPEN FOR EXTENDED PERIODS OF TIME.REFER TO THE SPECIFICATIONS FOR THE GEOTECHNICAL TESTING REQUIREMENTS.IF SOIL IS DISTURBED DURING FOOTING EXCAVATION RE-COMPACT TO 95% MODIFIED PROCTOR DENSITY IN 8" LIFTS.CENTER ALL FOOTINGS UNDER THEIR RESPECTIVE COLUMNS OR WALLS, U.N.O. ON PLANS.DO NOT EXCAVATE FOR ANY PURPOSE WITHIN ONE FOOT OF THE ANGLE OF REPOSE OF ANY SOIL BEARING FOOTING OR FOUNDATION UNLESS SUCH FOOTING OR FOUNDATION IS FIRST PROPERLY PROTECTED AGAINST SETTLEMENT.THE CONTRACTOR IS RESPONSIBLE FOR THE DISPOSAL OF ALL ACCUMULATED WATER FROM EXCAVATIONS AND DEWATERING OPERATIONS IN SUCH A WAY AS NOT TO CAUSE INCONVENIENCE TO THE WORK AND DAMAGE TO THE STRUCTURAL ELEMENTS.SOIL COMPACTION SHALL BE FIELD CONTROLLED BY A SOILS ENGINEER OR TESTING LABORATORY. A REPORT BEARING THE SIGNATURE AND SEAL OF A REGISTERED PROFESSIONAL ENGINEER WHO CONTROLLED AND TESTED THE SOIL COMPACTION SHALL BE SUBMITTED TO THE CONTRACTING OFFICER AS AN INDICATION THAT THE REQUIREMENTS OF THE CONTRACT DOCUMENTS HAVE BEEN FOLLOWED.SOIL COMPACTION, FILL AND ITS REPLACEMENT SHALL BE FIELD CONTROLLED BY THE TESTING AGENCY OR CONTRACTING OFFICER. THE TESTING AGENCY SHALL SELECT ALL TESTING LOCATIONS.
( ADHESIVE ANCHORING SYSTEMS )USE AN EPOXY OR POLYESTER RESIN ADHESIVE SUCH AS HILTI HIT HY-200 OR APPROVED EQUIVALENT.FOLLOW MANUFACTURER'S SPECIFICATIONS FOR USE AND INSTALLATION. INSTALL AND MAINTAIN A MIN. EMBEDMENT IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, OR AS SPECIFIED ON DRAWINGS. DIAMETER OF HOLE SHALL BE AS RECOMMENDED BY MANUFACTURER FOR THE PARTICULAR PRODUCT SPECIFIED IN THE DRAWINGS.UNLESS NOTED, ANCHOR SPACING AND ANCHOR EDGE DISTANCE SHALL BE ACCORDING TO THE MANUFACTURER'S MOST CURRENT PUBLICATION IN ORDER TO DEVELOP MAXIMUM WORKING LOADS.DO NOT EXCEED MANUFACTURER'S MAX. RECOMMENDED TIGHTENING TORQUE.ALL ANCHORS SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND UNDER MANUFACTURER'S SUPERVISION IN ORDER TO DEVELOP THE MOST CURRENT PUBLISHED WORKING LOADS.ALL EPOXIED ANCHORING SHALL BE TESTED AFTER INSTALLATION AT CONTRACTOR'S EXPENSE. A MINIMUM OF 10% OF EACH DAY'S APPLICATIONS AND NO LESS THAN 2 SHALL BE TESTED BY APPLYING A TENSING LOAD OF 1000 POUNDS TO THE EMBEDDED ANCHOR. IF A TEST APPLICATION FAILS, ALL APPLICATIONS FOR THAT DAY SHALL BE TESTED. TESTING PROCEDURES AND RESULTS SHALL BE SUBMITTED AND APPROVED BY ENGINEER.
c )
( SPECIAL STRUCTURAL INSPECTIONS )
Vma
rk
|
^ddvl
I SIZ
E:I A
NSI
D
I PLO
T SC
ALE
:
(DES
IGNE
D B
Y:
I S.S
MIT
H
1. EXTERIOR METAL STUDS AND ATTACHMENTS SHALL BE DESIGNED BY A SPECIALTYENGINEER. THE DESIGN SHALL CONFORM TO UFC 3-301-01, UFC 4-010-01, ANDB.I.A. TECHNICAL NOTE 28B. THE SIZES SHOWN ON THE DRAWINGS ARE A MINIMUMTO BE PROVIDED AND INSTALLED.
2. THE SPECIALTY ENGINEER OR MANUFACTURER SHALL PROVIDE, ANDINSTALL THEIR COMPONENTS, IT IS THE RESPONSIBILITY OF THE SPECIALTYENGINEER TO ENSURE ALL COMPONENTS ARE INSTALLED ACCORDING TO THEAPPROVED SHOP DRAWINGS. THE SPECIALTY ENGINEER SHALL SUBMIT A LETTERTO THE CONTRACTING OFFICER STATING THAT THE SYSTEM HAS BEEN INSTALLEDACCORDING TO THE APPROVED SHOP DRAWINGS.
3. METAL STUD ENGINEER SHALL REVIEW & COORDINATE METAL PANELS / SOFFITSUPPORT ATTACHMENTS PRIOR TO SHOP DRAWING SUBMITTAL.
4. COORDINATE, PROVIDE, AND INSTALL DOUBLE STUDS WITH METAL PANEL / SOFFITSUPPORT JOINTS, ATTACHMENT REQUIREMENTS AND SPACING.
5. PROVIDE STRAP BRACING TO BRACE FLANGES WHERE UNBRACED BY PANELS OR OTHER MEANS. ALL STRAP BRACING SHALL BE ANCHORED TO SOLID BLOCKING.6. COORDINATE UNBRACED FLANGE WITH SHEATHING LOCATIONS. WHERE NO
SHEATHING EXISTS PROVIDE STRAPPING OR BRACING OF UNSUPPORTED FLANGESAS REQUIRED TO RESIST GRAVITY AND WIND LOADS.
7. THE MINIMUM GAGE FOR EXTERIOR STUD FRAMING IS 16 GAGE.8. DESIGN SHALL BE IN ACCORDANCE WITH AISI "SPECIFICATION FOR THE DESIGN OF COLD FORMED STRUCTURAL MEMBERS".9. JOINTS AND CONNECTIONS SHALL BE MADE WITH SCREWS. PROVIDE A
MINIMUM TWO (2) SCREWS PER CONNECTION.10. POWDER ACTUATED FASTENERS (PAF'S) MAY BE USED IN NON-LOAD BEARING
APPLICATIONS.11. ALL COLD-FORMED STEEL FRAMING, CONNECTORS SHALL RECEIVE A G-90
GALVANIZED COATING.12. POWDER ACTUATED FASTENERS (PAF'S) EMBEDDED IN CONCRETE SHALL NOT BE
USED IN TENSION.13. EXTERIOR METAL STUDS AND THEIR CONNECTIONS ARE TO BE DESIGNED FOR
BLAST LOADS ACCORDING TO UFC 4-010-01.
1. USE POWDER ACTUATED FASTENING SYSTEMS SUCH AS HILTI, RED HEAD,RAMSET, OR AN ACCEPTED ALTERNATE HAVING I.C.B.O., OR S.B.C.G.I. APPROVAL.INSTALL IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, BUT NOTLESS THAN 1 1/4" INTO CONCRETE U.N.O.
2. PROVIDE A MINIMUM ANCHOR SPACING AND EDGE DISTANCE OF 3 INCHES INCONCRETE AND A MINIMUM ANCHOR SPACING OF 1 INCH AND EDGE DISTANCEOF 1/2 INCH IN STEEL.
3. ALLOWABLE WORKING LOADS SHALL NOT EXCEED MANUFACTURER'SRECOMMENDATIONS, BUT NOT MORE THAN ACCEPTED BY APPROVING AGENCY.NO INCREASE FOR WIND OR SEISMIC LOAD IS PERMITTED.
4. PROVIDE A MINIMUM OF TWO (2) FASTENERS PER CONNECTION.
1. USE 2 INCH DEEP, COMPOSITE STEEL DECK UNITS, FORMED OF20 GAUGE STEEL SHEETS CONFORMING TO ASTM A-446, HAVING AMINIMUM YIELD POINT OF 40 KSI, WITH A PROTECTIVE COATING OFZINC CONFORMING TO ASTM A-653 G90, AND HAVING INTEGRALLOCKING LUGS OR EMBOSSMENTS. MIN. HEIGHT OF EMBOSSMENTSOR LUGS SHALL BE .050".
A. Sp= 0.355 in^3/FT B. Sn= 0.360 in^3/FT C. Ip= 0.418 in^4/FT D. In= 0.415 in^4/FT2. THE DECK SHALL BE CAPABLE OF SUPPORTING A UNIFORMLY
DISTRIBUTED CONSTRUCTION LOAD OF 100 PSF AND TOTALSUPERIMPOSED LOADS LISTED UNDER GENERAL NOTES.
3. DESIGN AND MANUFACTURE THE DECK IN ACCORDANCE WITH THE"SPECIFICATIONS FOR DESIGN OF LIGHT-GAUGE COLD-FORMEDSTEEL STRUCTURAL MEMBERS", AND CONFORM TO THE STEELDECK INSTITUTE'S RECOMMENDED SPECIFICATIONS.
4. ERECT AND ANCHOR DECK UNITS IN ACCORDANCE WITH THEMANUFACTURER'S SPECIFICATIONS AND ERECTION DRAWINGS.ATTACH DECK TO SUPPORTS AS INDICATED.
5. USE 4" INCH THICK REGULAR WEIGHT CONCRETE SLAB ABOVETOP OF DECK. MINIMUM COMPRESSIVE STRENGTH OF CONCRETEIS 4000 PSI AT 28 DAYS, TYP U.N.O.
6. REINFORCE SLAB WITH 6x6 - W2.9xW2.9 PLACED 1 1/2 INCHESABOVE TOP OF STEEL DECK CORRUGATIONS.
7. GALVANIZED COMPOSITE FLOOR DECK SHALL BE OF THE DEPTH,GAGE, AND THICKNESS SPECIFIED ON THE DRAWINGS AND SHALLCONFORM TO ASTM A653 SQ GRADE 33 (Fy=33,000 PSI).GALVANIZED COATING SHALL CONFORM TO ASTM A924 WITH COATINGDESIGNATION G90.
8. THE COMPOSITE STEEL DECK SHOWN ON THE DRAWINGS IS THEMINIMUM REQUIRED FOR UNSHORED CONSTRUCTION FOR THE TYPICALCONDITION OF TWO CONTINUOUS SPANS OR MORE UNLESS SHORING ISSPECIFICALLY NOTED. THE DECK SUPPLIER SHALL INCREASE THE GAGETHICKNESS OR SPECIFY SHORING, IF NECESSARY, FOR SINGLE SPANCONDITIONS THAT CANNOT BE AVOIDED.
9. THE DECK GAGE AND DEPTH HAVE BEEN SELECTED BASED ON THE WETWEIGHT OF CONCRETE AND THE FINAL DESIGN LOADS ONLY.CONSTRUCTION MATERIALS MAY NOT BE PLACED ON THE BARE METALDECK.
10. THE FINAL SLAB THICKNESS SHALL BE NO LESS THAN INDICATED ONTHE PLANS AND THE SLAB SHALL BE FINISHED TO THE SPECIFIEDTHICKNESS. CONTRACTOR SHALL SUBMIT CONSTRUCTION JOINTLOCATIONS TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TOCONCRETE PLACEMENT. CONTRACTOR SHALL PROVIDE 10% ADDITIONALCONCRETE THAT MAY BE REQUIRED TO COMPENSATE FOR THEDEFLECTION OF UNSHORED BEAMS AND DECK.
11. SEE DETAILS FOR ATTACHMENT OF DECK TO SUPPORTS AND FOR SIDELAP CONNECTIONS BETWEEN SUPPORTS. PROVIDE DECK ACCESSORIESSUCH AS COLUMN CLOSURES, CELL CLOSURES, AND GIRDER FILLERSTO CONSTRUCT COMPLETE FLOOR DECK.
12. DECK SHALL BE FABRICATED SO THAT DECK RUNS CONTINUOUSLYOVER OPENINGS. THE OPENINGS IN THE DECK SHALL NOT BE CUTUNTIL THE OPENING IS NEEDED (PER OSHA).
13. THE CONTRACTOR SHALL COORDINATE ALL TRADE REQUIREMENTS ANDCONFIRM THE SIZE AND LOCATION OF ALL OPENINGS. OPENINGS LARGERTHAN 12", AND AS DETAILED, SHALL HAVE STEEL FRAMING SUPPORTINGALL EDGES. SEE TYPICAL FRAMING DETAILS.
14. STEEL MEMBERS (I.E. -EDGE ANGLES, PLATES, ETC.) SUPPORTING STEELDECK AT THE PERIMETER OF THE BUILDING SHALL BE CONTINUOUS,BUTT WELD PIECES WHERE SPLICES OCCUR.
15. CONDUIT, PIPING, ETC. SHALL NOT BE EMBEDDED IN COMPOSITE SLABCONSTRUCTION. MODIFICATION TO THE REFERENCED FIRE RATED DESIGNASSEMBLIES FOR ELEVATED COMPOSITE SLABS WILL NOT BE ALLOWED.SUCH MODIFICATIONS INCLUDE, BUT ARE NOT LIMITED TO, EMBEDDEDCONDUIT, PIPING, OR OTHER BUILDING ELEMENT OR SYSTEM NOTINDICATED INT THE REFERENCED ASSEMBLIES. REFER TO THEARCHITECTURAL DRAWINGS FOR THE FIRE RATED DESIGN ASSEMBLIESUSED ON THIS PROJECT.
16. CONSTRUCT COMPOSITE FLOORS TO Ff = 20 (13 MIN) PER ASTM E1155.
1. FOUNDATION DESIGN IS BASED ON AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000POUNDS PER SQUARE FOOT BY THE GEOTECHNICAL REPORT PREPARED BY THE U.S.ARMY CORPS OF ENGINEERS (USACE) MOBILE DISTRICT APRIL 2016.
2. GENERAL: EXISTING VEGETATED AREAS TO RECEIVE FILL SHALL BE STRIPPED OF ALLSURFACE VEGETATION AND TOPSOIL. TOPSOIL SUITABLE FOR REUSE SHALL BESTOCKPILED FOR REUSE. IF TOPSOIL IS REUSED, IT MAY REQUIRE FURTHER SOILAMENDMENTS BEFORE IT IS SUITABLE. THE CONTRACTOR SHALL REFER TO RELEVANTSPECIFICATIONS FOR FURTHER GUIDANCE. PROVISIONS SHALL BE MADE TO MAINTAIN ALLEXCAVATIONS FREE OF SURFACE WATER.
3. DEMOLITION: WHERE SURROUNDING PAVEMENTS AND STRUCTURES AREDEMOLISHED TO MAKE WAY FOR NEW CONSTRUCTION, BURIED COMPONENTSSHALL BE COMPLETELY REMOVED. ANY RESULTING VOIDS SHALL BE BACKFILLEDAND COMPACTED WITH SATISFACTORY SOILS. IF THERE ARE ANY UTILITY LINES THAT ARETO BE REMOVED AND ARE TOO DEEP FOR PROPER EXCAVATION, THEY MAY BE GROUTEDIN PLACE AFTER APPROVAL IS RECEIVED FROM BOTH THE CONTRACTING OFFICER ANDTHE USACE MOBILE DISTRICT OFFICE.
4. DEWATERING: THE WATER TABLE ENCOUNTERED DURING THE SUBSURFACEINVESTIGATIONS IS AT A STATIC DEPTH OF 15 FEET AND MAY AFFECT THE CONSTRUCTIONOF THE FOUNDATION SYSTEM. DEWATERING WILL BE NECESSARY FOR UTILITYCONSTRUCTION, UNDERCUTTING, AND RE-COMPACTION FOR STRUCTURAL FOOTINGS.BACKFILL SHALL BE PLACED IMMEDIATELY AS EXCAVATION PROGRESSES.
5. UNDERCUTTING FOR FOUNDATIONS: THE SOIL WITHIN 2.0 FEET OF THE BOTTOM OF ALLFOOTINGS SHALL BE UNDERCUT AND BACKFILLED WITH AN ENGINEERED FILL. IT ISANTICIPATED THAT THE IN-SITU MATERIAL USED DURING CONSTRUCTION WILL BECLASSIFIED AS SATISFACTORY AND REQUIRE ONLY DENSIFICATION VIA COMPACTION.THE NEW CONSTRUCTION IS ADJACENT TO THE EXISTING 39TH IOS BUILDING (B90074) ANDMAY INFLUENCE THE FOUNDATIONS SYSTEM OF THIS BUILDING. THERE SHALL NOT BEEXTENSIVE UNDERCUTTING NEXT TO THIS BUILDING. ONLY LIMITED UNDERCUTTING ANDRE-COMPACTION IS ALLOWED FOR ISOLATED REMOVAL OF UNSATISFACTORY MATERIALSOR FILLING VOIDS DUE TO UTILITY REMOVAL. FILL AND SUBGRADE COMPACTION FOR NEWFOOTINGS ADJACENT TO THE EXISTING BUILDING (WITHIN 5.0 FEET) SHALL BE COMPACTEDWITH HAND COMPACTORS IN 4" LOOSE LIFTS. ROLLER COMPACTION MAY NOT BE USEDWITHIN 5.0 FEET OF THE EXISTING 39TH IOS BUILDING. LARGE VIBRATORY EQUIPMENT WILLNOT BE USED FOR THIS PROJECT.
6. FOUNDATION RECOMMENDATIONS: THE NATIVE MATERIAL AT THE PROJECT SITE ISANTICIPATED TO BE SATISFACTORY FOR RE-COMPACTION. WHERE THE SUBGRADEAPPEARS TO BE UNSATISFACTORY IT SHALL BE UNDERCUT AND RE-COMPACTED. WHERETHE GRADE REQUIRES ADDITIONAL FILL IT SHALL BE CONSISTENT WITH THE NATIVE,SATISFACTORY MATERIAL; POORLY GRADED FINE-GRAINED SAND. ALL COMPACTEDMATERIAL SHALL BE PLACED IN 8" LOOSE LIFTS FOR HEAVY COMPACTION EQUIPMENT.HAND COMPACTION SHALL BE DONE IN 4" LOOSE LIFTS. TWO FEET OF UNDERCUTTING ANDRE-COMPACTION IS REQUIRED FOR FOOTINGS 10.0 FEET AWAY FROM THE EXISTINGBUILDING. DURING CONSTRUCTION, ALL SOIL IMPROVEMENT WITHIN 5.0 FEET OF THEEXISTING FOOTINGS SHALL BE PERFORMED BY HAND COMPACTION IN 4" LOOSELIFTS. ALL EXCAVATIONS SHALL BE MADE WITH THE INTENT TO EXECUTE THE REQUIREDCONSTRUCTION AND BACKFILL AS QUICKLY AS POSSIBLE. LARGE EXCAVATIONS SHALL NOTBE OPEN FOR EXTENDED PERIODS OF TIME.
7. REFER TO THE SPECIFICATIONS FOR THE GEOTECHNICAL TESTING REQUIREMENTS.8. IF SOIL IS DISTURBED DURING FOOTING EXCAVATION RE-COMPACT TO 95% MODIFIED
PROCTOR DENSITY IN 8" LIFTS.9. CENTER ALL FOOTINGS UNDER THEIR RESPECTIVE COLUMNS OR WALLS, U.N.O. ON
PLANS.10. DO NOT EXCAVATE FOR ANY PURPOSE WITHIN ONE FOOT OF THE ANGLE OF REPOSE OF
ANY SOIL BEARING FOOTING OR FOUNDATION UNLESS SUCH FOOTING OR FOUNDATION ISFIRST PROPERLY PROTECTED AGAINST SETTLEMENT.
11. THE CONTRACTOR IS RESPONSIBLE FOR THE DISPOSAL OF ALL ACCUMULATEDWATER FROM EXCAVATIONS AND DEWATERING OPERATIONS IN SUCH A WAY AS NOT TOCAUSE INCONVENIENCE TO THE WORK AND DAMAGE TO THE STRUCTURAL ELEMENTS.
12. SOIL COMPACTION SHALL BE FIELD CONTROLLED BY A SOILS ENGINEER OR TESTINGLABORATORY. A REPORT BEARING THE SIGNATURE AND SEAL OF A REGISTEREDPROFESSIONAL ENGINEER WHO CONTROLLED AND TESTED THE SOIL COMPACTION SHALLBE SUBMITTED TO THE CONTRACTING OFFICER AS AN INDICATION THAT THEREQUIREMENTS OF THE CONTRACT DOCUMENTS HAVE BEEN FOLLOWED.
13. SOIL COMPACTION, FILL AND ITS REPLACEMENT SHALL BE FIELD CONTROLLED BY THETESTING AGENCY OR CONTRACTING OFFICER. THE TESTING AGENCY SHALL SELECT ALLTESTING LOCATIONS.
1. ALL JOISTS SHALL BE DESIGNED AND FABRICATED BY THE MANUFACTURER, WITH STANDARD CAMBER, AND ERECTED IN ACCORDANCE WITH STEEL JOIST INSTITUTE, LATEST REVISION.2. STEEL JOIST MANUFACTURER SHALL SUBMIT ERECTION AND SHOP DRAWINGS SHOWING JOIST LOCATIONS, BRIDGING, CONNECTIONS AND DETAILS, SPECIAL AND EXTENDED ENDS, SLOPED SEATS AND ACCESSORIES REQUIRED FOR THE INSTALLATION OF JOISTS.3. JOISTS SHALL BE STORED ON WOOD SLEEPERS ON DRY, LEVEL GROUND. PERMANENTLY DEFORMED OR OTHERWISE DAMAGED JOISTS SHALL BE REPLACED AT THE CONTRACTORS'S EXPENSE.4. THE STEEL JOIST FABRICATORS SHALL SUBMIT CERTIFIED LETTERS TO THE
ARCHITECT STATING THAT HE HAS RECEIVED SPRINKLER DRAWINGS. THESTEEL JOIST FABRICATORS SHALL DESIGN THEIR PRODUCTS FOR LOADINGIMPOSED BY SPRINKLER MAIN SUPPLY LINES AND BRANCHES. THE STEELJOIST FABRICATORS SHALL BE SOLELY RESPONSIBLE FOR THE ADEQUACYOF THE JOIST DESIGNS. IF SPRINKLER DRAWINGS ARE NOT AVAILABLE, THEJOIST FABRICATORS SHALL USE A DESIGN LOAD OF 3 PSF APPLIEDAS UNIFORM OR CONCENTRATED LOADS WHICH CAN BE SUPPORTED BYTHEIR SYSTEMS.
5. K-SERIES JOIST STRUCTURAL STEEL SHALL BE ASTM A572, GRADE 50 (Fy = 50 KSI) UNLESS NOTED OTHERWISE.6. ALL JOISTS SHALL RECEIVE A COAT OF GRAY RUST INHIBITIVE PRIMER.7. THE STEEL JOIST MANUFACTURER SHALL INVESTIGATE THE JOISTS FOR A MINIMUM NET UPLIFT IN ACCORDANCE WITH THE STRUCTURAL NOTES AND FURNISH THE BRIDGING AND ATTACHMENTS NECESSARY TO ENSURE PROPER JOIST PERFORMANCE UNDER UPLIFT FORCES AND FORCES DUE TO ERECTION PER SJI SPECIFICATIONS AND OSHA REQUIREMENTS.8. STEEL JOIST BEARING AT EXTERIOR WALLS SHALL BE DESIGNED TO RESIST 1,200 POUNDS LATERAL FORCE PERPENDICULAR TO JOISTS APPLIED AT THE
TOP OF THE JOIST.9. ANY SINGLE PANEL POINT OF THE LOWER CHORD OF ROOF JOISTS MUST BE
CAPABLE OF SAFELY SUPPORTING A SUSPENDED CONCENTRATED LOAD OF200 POUNDS IN ADDITION TO THE DEAD LOADS.
10. UNLESS NOTED, K-SERIES STEEL JOISTS SHALL HAVE BEARING DEPTHS ASNOTED ON PLAN. WHERE STEEL JOIST SLOPE EXCEEDS 1/8" PER FOOT,PROVIDE SLOPED BEARING SEATS.
11. JOIST SEATS SHALL EXTEND A DISTANCE OF NOT LESS THAN 2-1/2" OVER STEEL SUPPORTS WHERE 2-1/2" LONG BEARING FOR K-SERIES JOISTS IS NOT PROVIDED. THE JOIST MANUFACTURER SHALL PROVIDE A SPECIAL JOIST SEAT DESIGN FOR ADEQUATE BEARING.12. JOIST SEATS SHALL EXTEND A DISTANCE OF NOT LESS THAN 4" OVER MASONRY
OR CONCRETE SUPPORTS AND CONNECT TO THE STEEL EMBED PLATES.13. UNLESS NOTED OTHERWISE OR AS REQUIRED BY DESIGN OF JOIST MANUFACTURER, K-SERIES JOISTS SHALL BE CONNECTED TO STEEL BY 1/8"
WELD, 2" LONG EACH SIDE.14. BRIDGING SHALL BE PROVIDED IN ACCORDANCE WITH S.J.I. REQUIREMENTS
WITH ADDITIONAL BRIDGING FOR UPLIFT TYPICAL AT EACH END OF ROOFJOISTS.
15. HORIZONTAL BRIDGING SHALL BE AN ANGLE AT TOP AND BOTTOM, DESIGNEDFOR L/R LESS THAN OR EQUAL TO 300. A SINGLE LINE OF BOTTOM CHORDBRIDGING MUST BE PROVIDED AT THE ENDS OF STEEL ROOF JOIST NEAR THEFIRST BOTTOM CHORD PANEL POINT.
16. DIAGONAL BRIDGING SHALL BE AN ANGLE DESIGNED FOR L/R LESS THAN OREQUAL TO 200.
17. UNLESS NOTED, 2ND AND 3RD JOIST SPACES FROM WALLS AND 1ST AND 2ND JOIST SPACES FROM DISCONTINUITIES SHALL HAVE CROSS BRIDGING (TO BE ALIGNED WITH HORIZONTAL BRIDGING).
18. PROVIDE AND INSTALL ADDITIONAL ROW AT BRIDGING AT THE FIRST PANEL POINTFROM THE ENDS OF THE JOISTS FOR UPLIFT.
19. JOIST BRIDGING SHALL NOT BE USED TO SUPPORT EQUIPMENT, PIPING,CONDUITS, DUCTWORK, ETC.
STEEL JOIST
1. USE AN EPOXY OR POLYESTER RESIN ADHESIVE SUCH AS HILTI HIT HY-200OR APPROVED EQUIVALENT.
2. FOLLOW MANUFACTURER'S SPECIFICATIONS FOR USE AND INSTALLATION.3. INSTALL AND MAINTAIN A MIN. EMBEDMENT IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS, OR AS SPECIFIED ON DRAWINGS.4. DIAMETER OF HOLE SHALL BE AS RECOMMENDED BY MANUFACTURER
FOR THE PARTICULAR PRODUCT SPECIFIED IN THE DRAWINGS.5. UNLESS NOTED, ANCHOR SPACING AND ANCHOR EDGE DISTANCE SHALL
BE ACCORDING TO THE MANUFACTURER'S MOST CURRENT PUBLICATION INORDER TO DEVELOP MAXIMUM WORKING LOADS.
6. DO NOT EXCEED MANUFACTURER'S MAX. RECOMMENDED TIGHTENINGTORQUE.
7. ALL ANCHORS SHALL BE INSTALLED AS PER MANUFACTURER'SRECOMMENDATIONS AND UNDER MANUFACTURER'S SUPERVISION INORDER TO DEVELOP THE MOST CURRENT PUBLISHED WORKING LOADS.
8. ALL EPOXIED ANCHORING SHALL BE TESTED AFTER INSTALLATION ATCONTRACTOR'S EXPENSE. A MINIMUM OF 10% OF EACH DAY'SAPPLICATIONS AND NO LESS THAN 2 SHALL BE TESTED BY APPLYING ATENSING LOAD OF 1000 POUNDS TO THE EMBEDDED ANCHOR. IF A TESTAPPLICATION FAILS, ALL APPLICATIONS FOR THAT DAY SHALL BE TESTED.TESTING PROCEDURES AND RESULTS SHALL BE SUBMITTED ANDAPPROVED BY ENGINEER.
1. SEE SPECIFICATION SECTION 01 45 35.00 25 FOR SPECIAL STRUCTURALINSPECTION REQUIREMENTS.
2. THE CONTRACTOR SHALL MEET ALL THE REQUIREMENTS FOR SPECIALINSPECTIONS IN ACCORDANCE WITH THE REQUIREMENTS OF CHAPTER 17OF THE INTERNATIONAL BUILDING CODE, 2012 EDITION.
CONSULTING GROUP,INC.
901 W. Garden St. Pensacola, FL 32502P: 850-438-0050 F: 850-432-8631
2. THE DECK SHALL BE CAPABLE OF SUPPORTING A UNIFORMLY DISTRIBUTEDTOTAL SUPERIMPOSED GRAVITY LOAD OF 55 PSF AND WIND UPLIFT ANDSHEAR LOADS LISTED UNDER GENERAL NOTES.
3. DESIGN AND MANUFACTURE THE DECK IN ACCORDANCE WITH THE"SPECIFICATIONS FOR DESIGN OF LIGHT GAGE COLD-FORMED STEELSTRUCTURAL MEMBERS", AND CONFORM TO THE STEEL DECK INSTITUTE'SRECOMMENDED SPECIFICATIONS.
4. ROOF DECK SHALL BE FASTENED TO THE SUPPORTING STRUCTURE WITH0.157"Ø P.A.F.'s IN A 36/7 FASTENER PATTERN AT ALL SUPPORTS WHEREBASE STEEL THICKNESS EXCEEDES 1/8" THICK. FOR APPLICATIONS WHEREBASE STEEL THICKNESS IS LESS THAN OR EQUAL TO 1/8" THICK, PROVIDE#12 BUILDEX TRAXX SCREWS IN A 36/7 FASTENER PATTERN AT ALLSUPPORTS. SIDE LAPS SHALL BE CONNECTED WITH #10 SELF DRILLINGSCREWS @12" O.C. MAX.
5. CEILING, DUCTS, AND LIGHT FIXTURES MAY BE HUNG FROM DECK. DO NOTHANG ANY OTHER ITEMS FROM ROOF DECK. NO SINGLE CONCENTRATEDLOAD SHALL EXCEED 60 POUNDS AND NO UNIFORM LOAD SHALL EXCEED 10PSF.
6. WHERE 4 OR MORE SUPPORTS ARE PROVIDED, STEEL DECK SHALL SPANCONTINUOUSLY OVER A MINIMUM OF 4 SUPPORTS (3-SPAN CONDITION).
STEEL ROOF DECK
ADHESIVE ANCHORING SYSTEMS
CONDITION CONNECTION- STUD TO
TRACK(1)-#10 SELF DRILLING SCREW, EACH FLANGE, STUDSECURELY INTO TRACK.
- TRACK TOCONCRETE
(2)-0.157Ø P.A.F.'s AT EACH STUD. PROVIDE A MINIMUMOF 1-1/2" EMBEDMENT, 2-1/2" EDGE OF DISTANCE, AND1" MINIMUM BETWEEN FASTENERS.
- TRACK TOSTRUCTURALSTEEL
(2)-0.157Ø P.A.F.'s @ 16"O.C. MAXIMUM. PROVIDE 1/2"MINIMUM EDGE DISTANCE AND 1" MINIMUM BETWEENFASTENERS.
SPECIAL STRUCTURAL INSPECTIONS
M) )c cSHOP DRAWINGS REQUIRING INPUT BY A _______ SPECIALTY ENGINEER_______1. THE FOLLOWING REQUIREMENTS IN NO WAY REDUCE OR LIMIT ANY ADDITIONAL
REQUIREMENTS OF SPECIFICATIONS.REVIEW OF SUBMITTALS BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AS PRESENTED BY THE CONTRACT DOCUMENTS. NO DETAILED CHECK OF QUANTITIES OR DIMENSIONS WILL BE MADE.ONLY THOSE SHOP DRAWINGS REQUIRED BY THE CONTRACT DOCUMENTS TO BE SUBMITTED WILL BE REVIEWED. ALL OTHERS WILL BE RETURNED WITHOUT COMMENT.IN ACCORDANCE WITH THE SPECIFICATIONS SUBMIT A COPY OF THE SHOP DRAWING SUBMITTAL REGISTER TO THE STRUCTURAL ENGINEER, SHOWING DATES OF SUBMITTAL FOR EACH SPECIFIC STRUCTURAL SECTION OF THE WORK, CONSISTENT WITH THE FOLLOWING CRITERIA:
A. SCHEDULE AND SUBMIT SHOP DRAWINGS FOR SPECIFIC COMPONENTS, SUCH AS COLUMNS, FOOTINGS, ETC., IN THEIR ENTIRETY. SHOP DRAWINGS FOR SIMILAR FLOORS SHALL BE SUBMITTED IN THE SAME PACKAGE.
B. SUBMIT SHOP DRAWINGS IN A TIMELY MANNER, CONSISTENT WITH THE ABOVE REQUIREMENTS.
4. ALL CHANGES AND ADDITIONS MADE ON RESUBMITTALS MUST BE CLEARLY FLAGGED AND NOTED. THE PURPOSE OF THE RESUBMITTALS MUST BE CLEARLY NOTED ON THE LETTER OF TRANSMITTAL. COTR REVIEW WILL BE LIMITED TO THE ITEMS CAUSING THE RESUBMITTAL.
5. DO NOT REPRODUCE THE CONTRACT DOCUMENTS FOR USE AS SHOP DRAWINGS.6. SHOP DRAWINGS NOT MEETING THE ABOVE CRITERIA OR SUBMITTED AFTER
FABRICATION WILL NOT BE REVIEWED.RESPONSIBILITIES OF DETAILERS AND FABRICATORS
A. GENERAL- SUBMIT SHOP DRAWINGS AND ANY OTHER SPECIAL INFORMATION NECESSARY FOR PROPER FABRICATION,ERECTION, AND PLACEMENT OF STRUCTURAL FABRICATIONS.INCLUDE PLANS, ELEVATIONS, AND SECTIONS. CLEARLY SHOW ANCHORAGES, CONNECTIONS, AND ACCESSORY ITEMS. THE DETAILER MUST INTERPRET THE CONTRACT DOCUMENTS AND CLEARLY CONVEY THIS INTERPRETATION TO THE FIELD IN THE FORM OF PLACING OR ERECTION DRAWINGS.
B. CONCRETE REINFORCING DETAILER- PROVIDE PLACING DRAWINGS FOR FABRICATION AND PLACING OF REINFORCING STEEL. THESE DRAWINGS SHALL INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: BAR LISTS, SCHEDULES,BENDING DETAILS, PLACING DETAILS, PLACING PLANS, AND PLACING ELEVATIONS.- CLEARLY SHOW ELEVATIONS OF ALL BEARING AND SHEAR
WALLS. INDICATE OPENINGS, DETAILS OF ALL REINFORCING WITH LOCATIONS OF SPLICES AND HOOKS, CONTROL JOINTS, EXPANSION JOINTS, LINTELS, CONCRETE BOND BEAMS, AND PILASTERS.
- CLEARLY SHOW BEAM ELEVATIONS AND SECTIONS. INDICATE BAR LENGTHS, HOOKS, STIRRUP SPACING, LAP SPLICES,OFFSETS, AND LOCATION OF BARS WITH RESPECT TO ALL SUPPORTS.
- CLEARLY SHOW COLUMN ELEVATIONS AND SECTIONS.INDICATE DOWELS, OFFSETS, LAP SPLICES, AND TIES.PLAN SECTIONS OF ALL COLUMNS MUST CLEARLY BE SHOWN.
- CLEARLY SHOW ELEVATION, SECTIONS, AND DETAILS OF ALL BEAM TO COLUMN CONNECTIONS.
- CLEARLY SHOW FOUNDATION REINFORCING. INDICATE BAR LENGTHS, LOCATION AND SPLICES OF CONTINUOUS BARS,AND BAR SUPPORTS. CLEARLY SHOW LOCATIONS OF ALL DOWELS ON PLAN. INDICATE FOOTING STEP LOCATIONS AND PROVIDE DETAILS.
8. FOR ADDITIONAL CRITERIA APPLICABLE TO SHOP DRAWINGS REQUIRING ENGINEERING INPUT BY A SPECIALTY ENGINEER, SEE NOTE HEADING "SHOP DRAWINGS REQUIRING INPUT BY A SPECIALTY ENGINEER"
FLORIDA LICENSE NUMBER 05371 901 W Garden St Pensacola, FL 325
P 850-438-0050 F 850-432-86311. AN EMPLOYEE OR OFFICER OF A FABRICATOR.2. AN EMPLOYEE OR OFFICER OF AN ENTITY SUPPLYING
COMPONENTS TO A FABRICATOR.3. AN INDEPENDENT CONSULTANT RETAINED BY THE
FABRICATOR OR HIS SUPPLIER.THE FOLLOWING SYSTEMS AND COMPONENTS AS A MINIMUM REQUIRE FABRICATION AND ERECTION DRAWINGS WITH INPUT BY A SPECIALTY ENGINEER, BUT ARE NOT LIMITED TO: STEEL JOISTS, PRE-ENGINEERED STAIR, WINDOW SYSTEMS, STOREFRONT SYSTEMS, ROOF SYSTEMS,LOUVERS, DOORS, AND CONNECTIONS TO THE STRUCTURE, LIGHT GAUGE METAL STUD FRAMING, AND ANY EXTERIOR ANCILLARY STRUCTURES.THE SPECIALTY ENGINEER OR MANUFACTURER SHALL DESIGN, PROVIDE, AND INSTALL THEIR COMPONENTS AND THE COMPONENT CONNECTIONS TO THE PRIMARY STRUCTURE PER THE WIND CRITERIA STATED IN THESE NOTES, THE REQUIREMENTS OF UFC 4-010-01, OR THE CURRENT GOVERNING BUILDING CODES, WHICHEVER IS MORE STRINGENT.SUBMITTALS SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT AND APPLICABLE CODES, LIST THE DESIGN CRITERIA, AND SHOW ALL DETAILS AND PLANS NECESSARY FOR PROPER FABRICATION AND INSTALLATION. CALCULATIONS AND SHOP DRAWINGS SHALL IDENTIFY SPECIFIC PRODUCT UTILIZED. GENERIC PRODUCTS WILL NOT BE ACCEPTED.SHOP DRAWINGS AND CALCULATIONS MUST BE PREPARED UNDER THE DIRECT SUPERVISION AND CONTROL OF THE SPECIALTY ENGINEER.SHOP DRAWINGS AND CALCULATIONS REQUIRE THE SEAL, DATE AND SIGNATURE OF THE SPECIALTY ENGINEER. COMPUTER PRINTOUTS ARE AN ACCEPTABLE SUBSTITUTE FOR MANUAL COMPUTATIONS PROVIDED THEY ARE ACCOMPANIED BY SUFFICIENT DESCRIPTIVE INFORMATION TO PERMIT THEIR PROPER EVALUATION. SUCHDESCRIPTIVE INFORMATION SHALL BEAR THE SEAL AND SIGNATURE OF THE SPECIALTY ENGINEER AS AN INDICATION THAT HE HAS ACCEPTED RESPONSIBILITY FOR THE RESULTS.REVIEW BY THE STRUCTURAL ENGINEER OF SUBMITTALS LIMITED TO VERIFYING THE FOLLOWING:
A. THAT THE SPECIALTY ENGINEER HAS UNDERSTOOD THE DESIGN INTENT AND HAS USED THE SPECIFIED STRUCTURAL CRITERIA. (NO DETAILED CHECK OF CALCULATIONS WILL BE MADE.)
B. THAT THE CONFIGURATION SET FORTH IN THE STRUCTURAL SUBMITTALS IS CONSISTENT WITH THE CONTRACT DOCUMENTS. (NO DETAILED CHECK OF DIMENSIONS OR QUANTITIES WILL BE MADE.)
1. THE FOLLOWING REQUIREMENTS IN NO WAY REDUCE OR LIMIT ANY ADDITIONALREQUIREMENTS OF SPECIFICATIONS.
2. REVIEW OF SUBMITTALS BY THE STRUCTURAL ENGINEER IS FOR GENERALCONFORMANCE WITH THE DESIGN CONCEPT AS PRESENTED BY THE CONTRACTDOCUMENTS. NO DETAILED CHECK OF QUANTITIES OR DIMENSIONS WILL BE MADE.ONLY THOSE SHOP DRAWINGS REQUIRED BY THE CONTRACT DOCUMENTS TO BESUBMITTED WILL BE REVIEWED. ALL OTHERS WILL BE RETURNED WITHOUTCOMMENT.
3. IN ACCORDANCE WITH THE SPECIFICATIONS SUBMIT A COPY OF THE SHOP DRAWINGSUBMITTAL REGISTER TO THE STRUCTURAL ENGINEER, SHOWING DATES OF SUBMITTALFOR EACH SPECIFIC STRUCTURAL SECTION OF THE WORK, CONSISTENT WITH THEFOLLOWING CRITERIA:
A. SCHEDULE AND SUBMIT SHOP DRAWINGS FOR SPECIFICCOMPONENTS, SUCH AS COLUMNS, FOOTINGS, ETC., INTHEIR ENTIRETY. SHOP DRAWINGS FOR SIMILAR FLOORS SHALLBE SUBMITTED IN THE SAME PACKAGE.
B. SUBMIT SHOP DRAWINGS IN A TIMELY MANNER, CONSISTENTWITH THE ABOVE REQUIREMENTS.
4. ALL CHANGES AND ADDITIONS MADE ON RESUBMITTALS MUST BE CLEARLY FLAGGEDAND NOTED. THE PURPOSE OF THE RESUBMITTALS MUST BE CLEARLY NOTED ON THELETTER OF TRANSMITTAL. COTR REVIEW WILL BE LIMITED TO THE ITEMS CAUSINGTHE RESUBMITTAL.
5. DO NOT REPRODUCE THE CONTRACT DOCUMENTS FOR USE AS SHOP DRAWINGS.6. SHOP DRAWINGS NOT MEETING THE ABOVE CRITERIA OR SUBMITTED AFTER
FABRICATION WILL NOT BE REVIEWED.7. RESPONSIBILITIES OF DETAILERS AND FABRICATORS A. GENERAL- SUBMIT SHOP DRAWINGS AND ANY OTHER SPECIAL
INFORMATION NECESSARY FOR PROPER FABRICATION,ERECTION, AND PLACEMENT OF STRUCTURAL FABRICATIONS.INCLUDE PLANS, ELEVATIONS, AND SECTIONS. CLEARLY SHOWANCHORAGES, CONNECTIONS, AND ACCESSORY ITEMS. THEDETAILER MUST INTERPRET THE CONTRACT DOCUMENTSAND CLEARLY CONVEY THIS INTERPRETATION TO THE FIELDIN THE FORM OF PLACING OR ERECTION DRAWINGS.
B. CONCRETE REINFORCING DETAILER- PROVIDE PLACINGDRAWINGS FOR FABRICATION AND PLACING OF REINFORCINGSTEEL. THESE DRAWINGS SHALL INCLUDE, BUT ARE NOTLIMITED TO THE FOLLOWING: BAR LISTS, SCHEDULES,BENDING DETAILS, PLACING DETAILS, PLACING PLANS, ANDPLACING ELEVATIONS.
- CLEARLY SHOW ELEVATIONS OF ALL BEARING AND SHEARWALLS. INDICATE OPENINGS, DETAILS OF ALL REINFORCINGWITH LOCATIONS OF SPLICES AND HOOKS, CONTROLJOINTS, EXPANSION JOINTS, LINTELS, CONCRETE BONDBEAMS, AND PILASTERS.
- CLEARLY SHOW BEAM ELEVATIONS AND SECTIONS. INDICATEBAR LENGTHS, HOOKS, STIRRUP SPACING, LAP SPLICES,OFFSETS, AND LOCATION OF BARS WITH RESPECT TO ALLSUPPORTS.
- CLEARLY SHOW COLUMN ELEVATIONS AND SECTIONS.INDICATE DOWELS, OFFSETS, LAP SPLICES, AND TIES.PLAN SECTIONS OF ALL COLUMNS MUST CLEARLY BESHOWN.
- CLEARLY SHOW ELEVATION, SECTIONS, AND DETAILS OF ALLBEAM TO COLUMN CONNECTIONS.
- CLEARLY SHOW FOUNDATION REINFORCING. INDICATE BARLENGTHS, LOCATION AND SPLICES OF CONTINUOUS BARS,AND BAR SUPPORTS. CLEARLY SHOW LOCATIONS OF ALLDOWELS ON PLAN. INDICATE FOOTING STEP LOCATIONSAND PROVIDE DETAILS.
8. FOR ADDITIONAL CRITERIA APPLICABLE TO SHOP DRAWINGS REQUIRING ENGINEERINGINPUT BY A SPECIALTY ENGINEER, SEE NOTE HEADING "SHOP DRAWINGS REQUIRINGINPUT BY A SPECIALTY ENGINEER"
1. SPECIALTY ENGINEER: A. DEFINITION - A FLORIDA REGISTERED PROFESSIONAL ENGINEER WHO
SPECIALIZES IN AND WHO UNDERTAKES THE DESIGN OF STRUCTURAL COMPONENTS OR STRUCTURAL SYSTEMS INCLUDED IN A SPECIFIC SUBMITTAL PREPARED FOR THIS PROJECT.
B. SHALL BE: 1. AN EMPLOYEE OR OFFICER OF A FABRICATOR. 2. AN EMPLOYEE OR OFFICER OF AN ENTITY SUPPLYING
COMPONENTS TO A FABRICATOR. 3. AN INDEPENDENT CONSULTANT RETAINED BY THE
FABRICATOR OR HIS SUPPLIER.2. THE FOLLOWING SYSTEMS AND COMPONENTS AS A MINIMUM REQUIRE
FABRICATION AND ERECTION DRAWINGS WITH INPUT BY A SPECIALTYENGINEER, BUT ARE NOT LIMITED TO: STEEL JOISTS, PRE-ENGINEEREDSTAIR, WINDOW SYSTEMS, STOREFRONT SYSTEMS, ROOF SYSTEMS,LOUVERS, DOORS, AND CONNECTIONS TO THE STRUCTURE, LIGHT GAUGE METALSTUD FRAMING, AND ANY EXTERIOR ANCILLARY STRUCTURES.
3. THE SPECIALTY ENGINEER OR MANUFACTURER SHALL DESIGN, PROVIDE, AND INSTALL THEIR COMPONENTS AND THE COMPONENT CONNECTIONS TO THEPRIMARY STRUCTURE PER THE WIND CRITERIA STATED IN THESE NOTES, THEREQUIREMENTS OF UFC 4-010-01, OR THE CURRENT GOVERNING BUILDING CODES,WHICHEVER IS MORE STRINGENT.
4. SUBMITTALS SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT AND APPLICABLECODES, LIST THE DESIGN CRITERIA, AND SHOW ALL DETAILS AND PLANSNECESSARY FOR PROPER FABRICATION AND INSTALLATION. CALCULATIONS ANDSHOP DRAWINGS SHALL IDENTIFY SPECIFIC PRODUCT UTILIZED. GENERICPRODUCTS WILL NOT BE ACCEPTED.
5. SHOP DRAWINGS AND CALCULATIONS MUST BE PREPARED UNDER THE DIRECTSUPERVISION AND CONTROL OF THE SPECIALTY ENGINEER.
6. SHOP DRAWINGS AND CALCULATIONS REQUIRE THE SEAL, DATE AND SIGNATUREOF THE SPECIALTY ENGINEER. COMPUTER PRINTOUTS ARE AN ACCEPTABLESUBSTITUTE FOR MANUAL COMPUTATIONS PROVIDED THEY ARE ACCOMPANIEDBY SUFFICIENT DESCRIPTIVE INFORMATION TO PERMIT THEIR PROPEREVALUATION. SUCHDESCRIPTIVE INFORMATION SHALL BEAR THE SEAL ANDSIGNATURE OF THE SPECIALTY ENGINEER AS AN INDICATION THAT HE HASACCEPTED RESPONSIBILITY FOR THE RESULTS.
7. REVIEW BY THE STRUCTURAL ENGINEER OF SUBMITTALS LIMITED TO VERIFYINGTHE FOLLOWING:
A. THAT THE SPECIALTY ENGINEER HAS UNDERSTOOD THEDESIGN INTENT AND HAS USED THE SPECIFIED STRUCTURALCRITERIA. (NO DETAILED CHECK OF CALCULATIONS WILL BE MADE.)
B. THAT THE CONFIGURATION SET FORTH IN THE STRUCTURAL SUBMITTALS IS CONSISTENT WITH THE CONTRACT DOCUMENTS. (NODETAILED CHECK OF DIMENSIONS OR QUANTITIES WILL BE MADE.)
5 5 5
5
4
4
WIND LOAD ZONE WALL DIAGRAM"a" = 8'-10"
"a"
1
NEGATIVE ZONE 1AREA
-48 -4510 SF 50 SF
WIND PRESSURE DIAGRAMCLADDING PRESSURES ROOF
-84 -68-44-62
100 SF
NEGATIVE ZONE 2-124 -105 -97NEGATIVE ZONE 330 24 21ALL POSITIVE ZONES
AREA-52 -45
10 SF 100 SF
CLADDING PRESSURES WALLS
-64 -50-40-40
500 SF
48 41 36ALL POSITIVE ZONES
NEGATIVE ZONE 4NEGATIVE ZONE 5
MWFRS = 45 PSF
PRESSURES ARE ULTIMATE
OVERHANG ZONE 1&2OVERHANG ZONE 3
-98 -98 -98-165 -128 -112
OVERHANG SOFFIT OR UNDERSIDE OF CANOPYPRESSURE EQUALS ADJ WALL PRESSURE(WHICH INCLUDES INTERNAL PRESSURE OF 8 PSF) 3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
21
1
2
23
2
3
3
2
3
1 22
23 3
5 5
5
44
WIND LOAD ZONE WALL DIAGRAM"a" = 8'-10"
"a"
12
23
23
32
3
5
CANOPY
CANOPY
OVERHANG
OVERHANG
CONSULTING GROUP,INC.
901 W. Garden St. Pensacola, FL 32502P: 850-438-0050 F: 850-432-8631
SHOP DRAWING SUBMITTALS SHOP DRAWINGS REQUIRING INPUT BY ASPECIALTY ENGINEER KSI KIPS PER SQUARE INCH
LB POUNDLL LIVE LOADLLV LONG LEG VERTICALLONG LONGITUDINALLW LIGHTWEIGHTMAX. MAXIMUMMECH MECHANIC(AL)MFR MANUFACTURE(R, ING)MIN. MINIMUMMISC. MISCELLANEOUSN.T.S. NOT TO SCALENW NORMAL WEIGHTO.C. ON CENTERPL PLATEPROJ. PROJECTIONPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHQTY QUANTITYREBAR REINFORCING BARREINF REINFORCE(D, ING)REQD. REQUIREDREV REVISION(S), REVISEDS.F. STEP FOOTINGSIM. SIMILARSJI STEEL JOIST INSTITUTESLV SHORT LEG VERTICALSPEC SPECIFICATION(S)SSMA STEEL STUD MANUFACTURER'S ASSOCIATIONT&B TOP AND BOTTOMTEMP TEMPERATURET.O. TOP OFT.O.C. TOP OF CONCRETET.O.F. TOP OF FOOTINGT.O.S. TOP OF STEELT.O.W. TOP OF WALLTRANS TRANSVERSET.S. THICKENDED SLABTYP. TYPICALU.N.O. UNLESS NOTED OTHERWISEVERT. VERTICALW/ WITHW/ O WITHOUTW.P. WORK POINTWWR WELDED WIRE REINFORCEMENT<<X/S-XXX>>
SECTION OR DETAIL REFERENCE
ACI AMERICAN CONCRETE INSTITUTEAISC AMERICAN INSTITUTE FOR STEEL
CONSTRUCTIONAISI AMERICAN IRON STEEL INSTITUTEALT ALTERNATEANSI AMERICAN NATIONAL STANDARDS INSTITUTEAPPROX APPROXIMATEARCH ARCHITECT(URAL)ASCE AMERICAN SOCIETY OF CIVIL ENGINEERSASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALSAWS AMERICAN WELDING SOCIETYBLDG. BUILDINGBOT BOTTOMBRG BEARINGCJ CONSTRUCTION JOINT / CONTROL JOINTCL CENTER LINECLR CLEAR, CLEARANCECMU CONCRETE MASONRY UNITCOL. COLUMNCONN CONNECTIONCONT CONTINUOUS, CONTINUEDIA, Ø DIAMETERDL DEAD LOADDWG. DRAWINGEA EACHEF EACH FACEEL. ELEVATIONE.J. EXPANSION JOINTE.W. EACH WAYE.O.S. EDGE OF SLABEQ EQUALEQUIP EQUIPMENTEXIST EXISTINGEXP EXPANSIONFF FINISHED FLOORF.O. FACE OFFS FOOTING STEPFT FOOT, FEETGA GAGE, GAUGEGALV. GALVANIZEDHDG HOT DIP GALVANIZEDHORIZ. HORIZONTALHSS HOLLOW STRUCTURAL STEELIN INCHJT. JOINTKSF KIPS PER SQUARE FOOT
12'-10"T.O.F. T.O.F.SLAB, SEE -4'-0" -4'-0"2' - 0"- ^-r-o" 1. SEE S001 FOR GENERAL STRUCTURAL NOTES.
CENTERLINE OF COLUMNS ARE CENTERED ON GRID, TYP., U.N.O.4" SLAB = 4" CONCRETE SLAB ON GRADE REINFORCED VW 6X6 W2.9XW2.9 W.W.R.ON 10 MIL VAPOR BARRIER ON 6" OF FREE DRAINING GRANULATE BASE, TYP., U.N.O.6" SLAB = 6" CONCRETE SLAB ON GRADE REINFORCED VW 6X6 W4.0XW4.0 W.W.R.ON 10 MIL VAPOR BARRIER ON 6" OF FREE DRAINING GRANULATE BASE.T/PICAL FINISH FLOOR ELEVATION = O'-O", U.N.O.T/PICAL TOP OF FOOTING ELEVATION = -(2'-8") FROM FINISH FLOOR ELEVATION, U.N.O. SEE BUILDING ELEVATIONS FOR STRUCTURAL STEEL FRAMING AROUND WINDOWS AND DOORS.CONTRACTOR TO COORDINATE RECESSED SLAB DIMENSIONS AND THICKNESS WITH EXACT EQUIPMENT PROVIDED PRIOR TO CONSTRUCTION. AFTER EQUIPMENT RAILS ARE INSTALLED, FILL RECESSED AREA WITH CONCRETE TO ELEVATION O'-O".USE TOO #4 REBAR AT REENTRANT CORNERS AS SHOWN.ALL CONTINUOUS FOOTING STEEL WILL BE CONTINUOUS THROUGH SPREAD FOOTINGS.
PRE-ENGINEERED STEEL STAIR INCLUDING UPPER AND INTERMEDIATE LANDINGS. SEE SPEC SECTION 05 51 00.PRIVIDE 8"X16" CMU BOND BEAM W/ 2 #5 T&B @ INTERMEDIATE LANDING STAIR SUPPORT.
SHEET NOTES:1. SEE S001 FOR GENERAL STRUCTURAL NOTES.2. CENTERLINE OF COLUMNS ARE CENTERED ON GRID, TYP., U.N.O.3. 4" SLAB = 4" CONCRETE SLAB ON GRADE REINFORCED W/ 6X6 W2.9XW2.9 W.W.R.
ON 10 MIL VAPOR BARRIER ON 6" OF FREE DRAINING GRANULATE BASE, TYP., U.N.O.4. 6" SLAB = 6" CONCRETE SLAB ON GRADE REINFORCED W/ 6X6 W4.0XW4.0 W.W.R.
ON 10 MIL VAPOR BARRIER ON 6" OF FREE DRAINING GRANULATE BASE.5. TYPICAL FINISH FLOOR ELEVATION = 0'-0", U.N.O.6. TYPICAL TOP OF FOOTING ELEVATION = -(2'-8") FROM FINISH FLOOR ELEVATION, U.N.O.7. SEE BUILDING ELEVATIONS FOR STRUCTURAL STEEL FRAMING AROUND WINDOWS
AND DOORS.8. CONTRACTOR TO COORDINATE RECESSED SLAB DIMENSIONS AND THICKNESS WITH
EXACT EQUIPMENT PROVIDED PRIOR TO CONSTRUCTION. AFTER EQUIPMENT RAILSARE INSTALLED, FILL RECESSED AREA WITH CONCRETE TO ELEVATION 0'-0".
9. USE TWO #4 REBAR AT REENTRANT CORNERS AS SHOWN.10. ALL CONTINUOUS FOOTING STEEL WILL BE CONTINUOUS THROUGH SPREAD FOOTINGS.11. A. PRE-ENGINEERED STEEL STAIR INCLUDING UPPER AND INTERMEDIATE LANDINGS.
SEE SPEC SECTION 05 51 00.B. PRIVIDE 8"X16" CMU BOND BEAM W/ 2 #5 T&B @ INTERMEDIATE LANDING
STAIR SUPPORT.
= 6" SLAB
= 1/2" RECESSED SLAB
TD = TURN DOWN
= COLUMNS SUPPORT 1 HOUR FIRE RATED OCCUPANCY SEPARATION TOBE PROTECTED WITH 1 HOUR RATEDGYPSUM WALLBOARD ASSEMBLY ULNO. X52B (UNRESTRAINED), REFER TO ARCHITECTURAL DRAWINGS FORADDITIONAL INFORMATION.
LEGEND:= C.J. (CONTROL JOINT)
= STEP DOWN
= 4 FILLED CELLS UNDER GIRDERS/RIDGE, SEE DETAIL 7/S-505
= MASONRY CONTROL JOINTLOCATE @ EDGE OF BRICK PILASTER, SEE ARCH. FOR DIM.
SECOND FLOOR FRAMING PLAN601. SEE S001 FOR GENERAL STRUCTURAL NOTES.CENTERLINE OF COLUMNS ARE CENTERED ON GRID, TYP., U.N.O.TTPiCAL FLOOR CONSTRUCTION = 2" 20 GAGE GALVANIZED COMPOSITE DECKING (D-1). 4" NW CONCRETE TOPPING REINFORCED WITH 6X6 W2.9XW2.9 W.W.F., TOTAL SU\B THICKNESS = 6" TYP., U.N.O.TTPiCAL FINISH FLOOR ELEVATION = 16'-8" /15'-8".TTPiCAL TOP OF STEEL ELEVATION = 16'-2"/15,-2".SEE BUILDING ELEVATIONS FOR STRUCTURAL STEEL FRAMING AROUND WINDOWS AND DOORS.CONTRACTOR TO COORDINATE RECESSED SLAB DIMENSIONS AND THICKNESS WITH EXACT EQUIPMENT PROVIDED PRIOR TO CONSTRUCTION. AFTER EQUIPMENT RAILS ARE INSTALLED, FILL RECESSED AREA WITH CONCRETE TO ELEVATION 0‘-0".
8. REFER TO DETAIL 9/S505 FOR CONCRETE POUR OVER DETAIL AT RAISED FLOOR AREAS.
9. [X] = QUANTITY OF 3/4"0x4" HEADED STUDS ON COMPOSITE BEAM.10. c = AMOUNT OF CAMBER AT BEAM MIDPOINT.11. BP = BEAM BEARING PLATE, SEE SCHEDULE FOR SIZES, 8/S506.12. SEE LINTEL DESIGNATION 1/S401.13. 8"x16" CMU BOND BEAM W/ 2 #5 CONT. T&B @ FLOOR LINE, TYP. ALL ELEVATOR14. A. PRE-ENGINEERED STEEL STAIR INCLUDING UPPER AND INTERMEDIATE LANDINGS.
SEE SPEC SECTION 05 51 00.B. PROVIDE 8"X16" CMU BOND BEAM W/2 #5 @ INTERMEDIATE LANDING FOR
STAIR SUPPORT.
PORTION OF STRUCTURAL FLOOR 2.ASSEMBLY (SLAB, STEEL DECK AND 3.BEAMS) SHALL BE PROTECTED WITH SPRAY APPLIED FIRE PROOFING MATERIAL TO PROVIDE A 1 HOUR FIRE 4. RATING, UL NO. D779 (UNRESTRAINED), 5. REFER TO ARCHITECTURAL DRAWINGS 6. FOR ADDITIONAL INFORMATION.
SHEET NOTES:1. SEE S001 FOR GENERAL STRUCTURAL NOTES.2. CENTERLINE OF COLUMNS ARE CENTERED ON GRID, TYP., U.N.O.3. TYPICAL FLOOR CONSTRUCTION = 2" 20 GAGE GALVANIZED
4. TYPICAL FINISH FLOOR ELEVATION = 16'-8" / 15'-8".5. TYPICAL TOP OF STEEL ELEVATION = 16'-2" / 15'-2".6. SEE BUILDING ELEVATIONS FOR STRUCTURAL STEEL FRAMING AROUND
WINDOWS AND DOORS.7. CONTRACTOR TO COORDINATE RECESSED SLAB DIMENSIONS AND THICKNESS
WITH EXACT EQUIPMENT PROVIDED PRIOR TO CONSTRUCTION. AFTER EQUIPMENTRAILS ARE INSTALLED, FILL RECESSED AREA WITH CONCRETE TO ELEVATION 0'-0".
LEGEND:= STEP DOWN
= 4 FILLED CELLS,SEE DETAIL 7/S-505
= CMU
= MOMENT FRAME
= LINTELS, SEE 1/S401
1/8" = 1'-0"1 SECOND FLOOR FRAMING PLAN8. REFER TO DETAIL 9/S505 FOR CONCRETE POUR OVER DETAIL AT RAISED FLOORAREAS.
9. [X] = QUANTITY OF 3/4"Øx4" HEADED STUDS ON COMPOSITE BEAM.10. c = AMOUNT OF CAMBER AT BEAM MIDPOINT.11. BP = BEAM BEARING PLATE, SEE SCHEDULE FOR SIZES, 8/S506.12. SEE LINTEL DESIGNATION 1/S401.13. 8"x16" CMU BOND BEAM W/ 2 #5 CONT. T&B @ FLOOR LINE, TYP. ALL ELEVATOR14. A. PRE-ENGINEERED STEEL STAIR INCLUDING UPPER AND INTERMEDIATE LANDINGS.
SEE SPEC SECTION 05 51 00.B. PROVIDE 8"X16" CMU BOND BEAM W/ 2 #5 @ INTERMEDIATE LANDING FOR
STAIR SUPPORT.
= PORTION OF STRUCTURAL FLOOR ASSEMBLY (SLAB, STEEL DECK AND BEAMS) SHALL BE PROTECTED WITHSPRAY APPLIED FIRE PROOFING MATERIAL TO PROVIDE A 1 HOUR FIRERATING, UL NO. D779 (UNRESTRAINED),REFER TO ARCHITECTURAL DRAWINGSFOR ADDITIONAL INFORMATION.
•r-o"
W24X55
I IBEAM SPLICE, TYP.
b CO
CM
<2.'k.V S'Zÿ'IS -VCVV "SZZD .'V_'V_\ V-V-W Vl 2V. V. VI V.V.V.'^_\ WV_V. VWV^ Y, £
21 - 3"ic4-2
S505/I4
3*1 H
b h
g I A. ;D-1;S506
j^X\y S506/Ifb4CO
CO 44- r-oM*i r-o" 2
4h4
S506
W16X26 W21X44 W24X55iiX
W10X19 <DI 7 ç^\
\S505 /
HOIST BEAM, BOTTOM AT BEAM 12'-4" ELEV. ABOVE FLOOR
LEGEND: SHEET NOTES:1. SEE S001 FOR GENERAL STRUCTURAL NOTES.
CENTERLINE OF COLUMNS ARE CENTERED ON GRID, TYP., U.N.O.1-1/2" DEEP, 20 GA. TYPE B GALVANIZED METAL ROOF DECK CONFORMING TO THE STEEL DECK INSTITUTE (SDI) RECOMMENDED PRACTICE. FASTEN WITH A 36/7 FASTENER LAYOUT USING #12 SCREW AT ALL JOIST SUPPORTS AND PERIMETER ANGLES, AND O.157"0 P.A.F. FASTENERS AT ALL BEAMS, PRE DRILL AS REQUIRED. SIDE LAPS SHALL HAVE (6) #10 SCREW BETOEEN SUPPORTS. ALL SCREWS SHALL BE SELF DRILLING W/ HEX HEAD WASHER OR APPROVED EQUIVALENT, TYP., U.N.O., SCREWS SHALL HAVE A MINIMUM PULLOUT VALUE OF 400 LB (ULT.) AND A MINIMUM SHEAR VALUE OF 965 LB (ULT.).
SHEET NOTES:1. SEE S001 FOR GENERAL STRUCTURAL NOTES.2. CENTERLINE OF COLUMNS ARE CENTERED ON GRID, TYP., U.N.O.3. 1-1/2" DEEP, 20 GA. TYPE B GALVANIZED METAL ROOF DECK
CONFORMING TO THE STEEL DECK INSTITUTE (SDI) RECOMMENDEDPRACTICE. FASTEN WITH A 36/7 FASTENER LAYOUT USING #12 SCREWAT ALL JOIST SUPPORTS AND PERIMETER ANGLES, AND 0.157"Ø P.A.F.FASTENERS AT ALL BEAMS, PRE DRILL AS REQUIRED. SIDE LAPS SHALL
HAVE (6) #10 SCREW BETWEEN SUPPORTS. ALL SCREWS SHALL BESELF DRILLING W/ HEX HEAD WASHER OR APPROVEDEQUIVALENT, TYP., U.N.O., SCREWS SHALL HAVE A MINIMUM PULLOUT VALUEOF 400 LB (ULT.) AND A MINIMUM SHEAR VALUE OF 965 LB (ULT.).
8" 10' - 0" 8" SCHMIDT1 8" 10' - 0" 8"6 1/2" TO BACK OF ANGLE
CONSULTING-GROUP,INC.S507PROTECT ROOF RAFTER SIM A-6 1/2" TO BACK-
OFANGLE
MECHANICAL ELECTRICAL STRUCTURAL COMMU NICATIONS I INDUSTRIAL4 ’ T
y 8"X16" BOND BEAM FLORIDA license number osstt VW 2 #5 CONT_____ 90pW8æ-438ooæ tTæSæSœî*LIGHT GAGE METAL
FRAMING BEYOND02
6 1/2" TO BACK^- OF ANGLE/k TYP. STUART SMITH P.E.
FLORIDA LICENSE NUMBER 49738D VENEER SUPPORT BEYOND
X x “x1-1/2" STEEL ROOF DECK
SC G PROJECT: 2015-176:IT-6 3/4"* X X x
I j11-6 3/4" £ tX4- 1-1/2" STEEL ROOF DECK
'T.O.J.12" T.O.J.6 1/2" TO BACK OF ANGLE
\ /1/4"X6"X6" BENT PLATE, CONT., TYP.
2" r 12"!■ Qxxlxxj IT-2 3/4"I! 1/4"X6"X6" BENT
PLATE, CONT., TYP.
10'-1 3/8"
12"11'-2 3/4"\ 7T.O.W. |
BOT. OF ANGLE W ody\
X T.O.W. \»Nt10'-1 3/8" X
I X nT1 XSET @ COURSINGT.O.J. T.O.J.X \X J X
9'-9 3/8" -9'-9 3/8"------XEl xX JOIST, SEEII\ 7T.O.W. T.O.W.-JOIST, SEE PLAN X Xi ii PLANXI oX ALIGN BOT. OFI XX \W10 BEYOND X X -VX \ -8'-8" SEE DETAIL 7/S401
FOR REINFORCING8" CONCRETE CAP W/2 #5 CONT., TYP. X LINTEL ANGLE W/
COURSING—X I l_ X I-—■df-
Xi 8" CONCRETE CAP W/2 #5 CONT., TYP.
\*X \3/4' CAP PLATE W/ (4)-3/4"0 A325 BOLTS Xi----------N X ii
NOTE: PLACE CONTROL JOINT AT 12'-0" MAXIMUM SO AS TO LIMIT CONCRETE PLACEMENT TO 144 S.F. MAXIMUM FOR ALL 4" FLOATING SLABS ON GRADE. DO NOT EXCEED A 2 T01 WIDTH TO LENGTH RATIO. SEE PLAN FOR LOCATIONS.
coCO SCHMIDTwg CONSULTING-GROUP,INC.
x MECHANICAL ELECTRICAL STRUCTURAL COMMU NICATIONS I INDUSTRIALSAW CUT WITHIN 8HRS
(MAX) AFTER PLACING CONCRETE. FILL WITH POURED JOINT FILLER
PROVIDE PREFORMED METAL GALVANIZED KEY OR 50x50 KEYWAY
z:SLAB< 3
P: 895-438-0095 F: 895-432-8631g 02REINFORCING SEE PLAN
o_CO UJ_u STUART SMITH P.E.
FLORIDA LICENSE NUMBER 49738T J—<> i XX00UJ_u3 ooLx-----X. SC G PROJECT: 2015-176
-1*—*
\--- WCL
VAPOR BARRIERUJLU
UJLUVAPOR BARRIER VAPOR
RETARDERco co r-o" r-o" 6" 6"t__ ^
SEE PLANS FOR LOCATIONS. COORDINATE SIZE AND DEPTH OF RECESS W/ARCHITECTURAL
CONTRACTION JOINT CONSTRUCTION JOINT
V S300JSLAB JOINT
V S300JRECESSED SLAB
3/4" = r-0" 3/4" = r-0"
IICMU WALL SEE PLANXT SEE CMU WALL
REINFORCING NOTES FOR SIZE & SPACING
D LAP DOWELS 48 BAR DIAMETER MATCH SIZE AND SPACING OF WALL REINFORCING
LAP DOWELS 48 BAR DIAMETERS
SEE CMU WALL REINFORCING NOTES
FOR SIZE AND SPACING
?STOP REINF @ JOINT
8" CMU WALL ^ (1) #5 CONT.90° HOOK OR EPOXY W/10"
MIN EMBEDMENT
3 3/4V UJUJ
o_(1) #5 CONT
IDUJUJ 00 O'-O"
A00
IL--------H■■'.-I%/ -1
/- ------------ ' F.F.E.î“ b&----------- /—-x^-7_
UUJ==JJJ==JlTl
VAPORRETARDER
(3) #5 CONTrrrillTTTl VAPORRETARDER
2‘ - 0"(3) #5 CONT2‘ - 0"
NOTE: PROVIDE T.S. UNDER ALL CMU WALLS AND WHERE NOTED ON PLANS, TYPICAL UNLESS NOTED OTHERWISE
NOTE: PROVIDE T.S. UNDER ALL CMU WALLS AND WHERE NOTED ON PU\NS. TYPICAL UNLESS NOTED OTHERWISE
INTERIOR THICKENED SLAB @ 8" PARTITION CMU WALL
TYPICAL CONTROL JOINT @ PARTITION CMU WALL(2^
V S300J V S300 73/4" = r-0" 3/4" = r-0"
11 - 3 5/8"
+ fr-3 5/8"A A
X XX \VENEER
SEE ARCH DWGSVENEER
SEE ARCH DWGS8" CMU 8" CMUX \X \XLAP DOWELS 48 BAR
DIAMETER MATCH SIZE & SPACING OF
WALL REINFORCING
LAP DOWELS 48 BAR DIAMETER MATCH
SIZE & SPACING OF WALL REINFORCING
\X \SEE CMU WALL
REINFORCING NOTES FOR SIZE & SPACING
SEE CMU WALL REINFORCING NOTES FOR SIZE & SPACING
X XX \X XX X(2) #5 CONT (2) #5 CONTX XX X1/2" EXPANSION
JOINT1/2" EXPANSION JOINTX X LX XO'-O" O'-O"
FILL AIRSPACE BELOW GRADE W/GROUT
FILL AIRSPACE BELOW GRADE W/GROUTX \
»—»—»-X F.F.E. XX X/!■/PC COz:
X3VAPORRETARDERX X\o_—TT ^TTs sX UJ
UJX âi âi!!CO
-
X v aUJUJ —nr
-1--*1-y
£ F.F.E.CO CO
0 VAPORRETARDERlirSEE PLAN SEE PLANta
•-■•XX*" ' ;
T.O.F. T.O.F.; 4**
s sUJUJ
UJUJ5
âi âico co«'•
EQ ^ EQ EQEQ 0 8" r-4" 2-8"SEE FOUNDATION SCHEDULE FOR SIZE AND REINFORCING
SEE FOUNDATION SCHEDULE FOR SIZE AND REINFORCINGSEE PLAN SEE PLAN
#6 @12" O.C., E.W., T&B -.2 #6@12" O.C., E.W., T&BNOTES:FOOTING STEP SHALL BE PLACED 24" FROM CENTER ON BOTH SIDES OF PIPES OR CONDUITS. SEE PLAN FOR LOCATIONS.
02CASE 1 :(1) OPENINGS IN NON-STRUCTURAL PARTITIONS OVER 100 SQ. INCHES(2) ANY OPENING 24" OR LESS,BOTH SIDES, ANDOVER100 SQ. INCHES IN STRUCTURAL OR EXTERIOR WALLS.
STUART SMITH P.E. FLORIDA LICENSE NUMBER 49738 S
SC G PROJECT: 2015-176
MIN.1,#5 BAR,TYP.
I
IOPENING
>\48 BAR DIA. OR 3'-0" MIN."
Il!
isIQ
V S400JWALL REINFORCEMENT AT OPENINGSNTS
CASE 3APPLIES TO STRUCTURAL. AND EXTERIOR WALLS WHEN OPENING EXCEEDS 48 INCHES BUT NOT MORE THAN 72"IN EITHER DIRECTION
OPENING -
48 BAR DIA. OR 3'-0" MIN"
48 BAR DIA._OR 3'-0" MIN
ÇZ\VS400J
WALL REINFORCEMENT AT OPENINGNTS
REINFORCED CELLS EACH SIDE OF JOINT, TYP.(STOP LONGITUDINAL WIRES @ EACH SIDE OF MCJ, TYP.)
STRUCTURAL BOND BEAM REINFORCEMENT CONTINUOUS ACROSS CONTROL JOINT LADDER TYPE JOINT
REINF., TYP.ALL BOND BEAM
REINFORCING SHALL BE CONTINUOUS
ACROSS MASONRY CONTROL JOINTS
2 MCJ
PQ DQ PQ-EXTEND DOWEL
REINFORCING INTO UPPERMOST BOND BEAM
WITH 90° HOOKS
H—H l l l l i|i S l i lD
JEXTERIOR VENEER
DETAIL
LADDER TYPE JOINT REINF., TYP.
%m ------ HORIZ. JOINT REINF.(CUT JOINT REINFORCEMENT AT CONTROL JOINT)
-— INTERIOR CMU WALL
EXTERIOR VENEER —- <'S7’
3 SECTIONMASONRY CONTROL JOINT
mmMATCH TYPICAL WALL REINFORCING EACH SIDE OF
CONTROL JOINT, TYP. mm2\sm J
DOUBLE WYTHE WALL REINFORCEMENT&NTS
LAP 48 BAR DIAMETERS, TYP. U.N.O.
C 3/8".-INTERIOR FACE
STRUCTURAL BOND BEAM REINFORCEMENT
CONTINUOUS ACROSS CONTROL JOINT
-f--------- UV--—i---------- *m. » . -
«mr RAKE 1/4"
CONTINUOUS FOOTING AYFINISHED FLOOR DETAILRAKE JOINT 1/4" AT INTERIOR
FACE OF EXPOSED WALLS. AYDETAIL
CONTROL JOINT KEY STOP LONGITUDINAL WIRES AT ALL C.J.'S INTERIOR FACE OF CMU WALL
SAME BAR SIZE AS VERTICAL WALL
REINFORCING —]B LVAPOR
BARRIER, TYP.
35
116" CAPILU\RY WATER BARRIER, TYP.
~
MBOUTSIDE FACE OF SLAB
AYCOMPACTED FILL DETAILDOWELS TO MATCH WALL REINFORCING RAKE 3/4"
BACKER ROD j AND SEALANT
W = 3/8"-EXTERIOR FACE f?'
%DETAIL AY CNJ
gACMU CONTROL JOINTS ARE NOT TO EXCEED 24‘, TYP U.N.O THE JOINTS SHALL BE LOCATED A MINIMUM OF 24" FROM DOOR OR WINDOW OPENINGS TO MISS LINTELS. THE HORIZONTAL JOINT REINFORCING SHALL BE TERMINATED 2" FROM EACH SIDE OF JOINT. ALL BOND BEAM REINFORCING SHALL CONTINUE THRU THE JOINT.
TRANSVERSEFOOTING
REINFORCEMENT
UNDISTURBED OR COMPACTED SUB-GRADE, TYP.
CONTINUOUSFOOTINGREINFORCEMENT
A
TYP CONTROL JOINT DETAIL w/ RUBBER KEYVS400 7
ISOMETRIC VIEWVS400 V \S400J
WALL REINFORCEMENT @ OPENINGNTS NTS NTS
SHEETIDENTIFICATION
S400
1 2 3 4 5
I 48 BA
R D
IA.
^TO
R 3
'-0" M
IN.
OR
3'-0
" MIN
.■Jr
x-48
BAR
DIA
.
Jr-
48 B
AR
DIA
. "O
R 3
'-0" M
IN.
\L
\/
x
//
A\
z
\MAR
KFI
LE N
AM
E:
S40
0ES
13.D
WG
I SIZ
E:I A
NS
I D
BULL
OC
K TI
CE
ASSO
CIA
TES
909
E. C
ERVA
NTE
S ST
REE
T, S
UIT
E B.
PE
NSA
CO
LA, F
LOR
IDA
PLO
T D
ATE:
08
FEB
, 201
7P
RO
JEC
T N
UM
BER
: M
015E
S13
1:1
I PLO
T S
CA
LE:
MA
SON
RY
DET
AIL
SS
UB
MIT
TED
BY:
S.
SMIT
HC
ON
TRA
CT
NO
.:
U.S
. AR
MY
CO
RPS
OF
ENG
INEE
RS
M
OB
ILE
DIS
TRIC
T M
OB
ILE
, ALA
BAM
AC
KD B
Y:
S. S
MIT
HD
WN
BY:
J.
KE
LLY
SO
LIC
ITA
TIO
N N
O.:
W91
278-
17-R
-001
0
FY16
AD
DIT
ION
TO
39
IOS
FAC
ILIT
Y
HU
RLB
UR
T FI
ELD
, FLO
RID
A
DAT
E:FE
BRU
ARY
8, 2
017
I DE
SIG
NE
D B
Y:
IS.S
MIT
H
DOWELS TO MATCHWALL REINFORCING
TRANSVERSEFOOTING
REINFORCEMENTCONTINUOUSFOOTINGREINFORCEMENT
UNDISTURBED ORCOMPACTEDSUB-GRADE, TYP.
OUTSIDE FACE OF SLAB
CONTINUOUS FOOTING
MASONRY CONTROL JOINT
HORIZ. JOINT REINF.(CUT JOINT REINFORCEMENTAT CONTROL JOINT)
STRUCTURAL BOND BEAMREINFORCEMENTCONTINUOUSACROSS CONTROL JOINT
STRUCTURAL BOND BEAMREINFORCEMENT
CONTINUOUSACROSS CONTROL JOINT
LAP 48 BAR DIAMETERS,TYP. U.N.O.
FINISHED FLOOR
COMPACTED FILL
6" CAPILLARY WATERBARRIER, TYP.
VAPORBARRIER, TYP.
ALL BOND BEAMREINFORCING SHALL
BE CONTINUOUSACROSS MASONRY
CONTROL JOINTS
MATCH TYPICAL WALLREINFORCING EACH SIDE OF
CONTROL JOINT, TYP.
EXTEND DOWELREINFORCING INTO
UPPERMOST BOND BEAMWITH 90° HOOKS
OPENING
CASE 1 :(1) OPENINGS IN NON-STRUCTURALPARTITIONS OVER 100 SQ. INCHES(2) ANY OPENING 24" OR LESS,BOTH SIDES, AND OVER100 SQ. INCHES IN STRUCTURALOR EXTERIOR WALLS. MIN. 1,#5 BAR,
TYP.
OR 3'-0" MIN.48 BAR DIA.
OR 3'
-0" M
IN.
48 B
AR D
IA.
MIN. 1, #5 BAR (TYP.)
OPENING
CASE 2 :APPLIES TO STRUCTURAL.AND EXTERIOR WALLS WHENOPENING EXCEEDS 24 INCHESBUT NOT MORE THAN48 INCHES IN EITHERDIRECTION.
SEE WALL SCHEDULE,MIN. 1,#5 BAR, TYP.
SEE LINTEL SCHED. ON S401
OR 3'
-0" M
IN.
48 B
AR D
IA.
OR 3'
-0" M
IN.
48 B
AR D
IA.
OR 3'-0" MIN48 BAR DIA.
SEE LINTEL SCHED
OPENING
CASE 3APPLIES TO STRUCTURAL.AND EXTERIOR WALLS WHENOPENING EXCEEDS 48 INCHESBUT NOT MORE THAN 72"IN EITHER DIRECTION
CMU CONTROL JOINTS ARE NOT TO EXCEED 24', TYPU.N.O THE JOINTS SHALL BE LOCATED A MINIMUM OF24" FROM DOOR OR WINDOW OPENINGS TO MISSLINTELS. THE HORIZONTAL JOINT REINFORCING SHALLBE TERMINATED 2" FROM EACH SIDE OF JOINT. ALLBOND BEAM REINFORCING SHALL CONTINUE THRU THEJOINT.
INTERIOR FACE
RAKE 1/4"
STOP LONGITUDINALWIRES AT ALL C.J.'SINTERIOR FACEOF CMU WALL
RAKE JOINT 1/4" AT INTERIORFACE OF EXPOSED WALLS.
CONTROL JOINT KEYSAME BAR SIZE AS
VERTICAL WALLREINFORCING
RAKE 3/4"
EXTERIOR FACE BACKER RODAND SEALANT
W = 3/8"
W/2,
(1/4"
MIN
.)
3/8".
EXTERIOR VENEER
LADDER TYPE JOINTREINF., TYP.
EXTERIOR VENEER
LADDER TYPE JOINTREINF., TYP.
INTERIOR CMU WALL
REINFORCED CELLS EACHSIDE OF JOINT, TYP.(STOP LONGITUDINAL WIRES@ EACH SIDE OF MCJ, TYP.)
MCJ
DETAIL
SECTION
CONSULTING GROUP,INC.
901 W. Garden St. Pensacola, FL 32502P: 850-438-0050 F: 850-432-8631
HORIZONTAL JOINT REINFORCING SEE REINFORCING NOTES,
OPENING SEE 3' - 0" MIN. 2' - 0"
ARCHITECHURAL TYP. TYP. MAX.Il! ! J_ _ _ _ _ L 1i: I
i i i 25 B1-4------- 1--------- 1I 4•3® PEA GRAVEL
CONCRETE, TYP.USE PREFABRICATED "T" AND "L" JOINT REINFORCING SHAPES AT CORNERS AND INTERSECTIONS. PROVIDE MINIMUM LENGTHS AS INDICATED.
3 /8" MIN BOND BEAM W/2-#5 BARS ABOVE
& BELOW OPENING
OPENI I
mm.VERTICAL REINFORCING TYP. Ill
my HORIZONTAL JOINT REINFORCING, SEE
REINFORCING NOTES, TYP.EEEEEEEEEHEE
ii i i l r2-BARS EACH SIDE OF OPENING IN GROUTED CELL FULL HEIGHT
OF WALL. BAR SIZE TO MATCH WALL REINFORCING.
I I
tSEEPLANTYP.
WIDTH
TOP STEELwXf -
2 "Z" BAR
BOTTOMSTEEL.iX
WIDTH^/C 7
WIDTH^C 7 1/4" GUSSET PLATE
@ Z-0" O.C. #3 TIESTOP STEEL
1 "Z" BARHI':rXj»M
nBOTTOM STEEL
P ;1
\
HDG 7 1/2"x6"x3/8" SLV BENT PU\TE W/ 5/8"0x5" EPOXY ANCHORS @24" O.C. MAX & 3/8" GUSSET PLATES @24" O.C. STAGGER GUSSET PLATES W/ BOLT LOCATIONS. EXTEND 8" PAST OPENING, HOT DIP GALVANIZE AFTER FABRICATION. 0" PROJECTION BOLT FLUSH W/NUT
HDG 7 1/2"x6"x3/8" SLV BENT PU\TE W/ 5/8"0x5" EPOXY ANCHORS @24" O.C. MAX & 3/8"
GUSSET PLATES @24" O.C. STAGGER GUSSET PLATES W/ BOLT LOCATIONS. EXTEND 8" PAST OPENING, HOT DIP GALVANIZE AFTER FABRICATION. 0" PROJECTION, BOLT FLUSH W/NUT
VS401JCORNER PILASTER DETAIL Çî\
\sS401JROLL UP DOORJAMB DETAIL
VS401JSECTION @ CONNECTOR
3/4" = r-0" 11/2" = r-0" 3/4" = r-0"
CONCRETE MASONRY UNIT CMU CONCRETE INTERIOR CMU LINTEL
VS401JTYPICAL WALL REINFORCING
VS401JCIRCULAR OPENING IN MASONRY WALL
VS401JSQUARE OPENING IN MASONRY WALL
NTS NTS NTS
T
SCHMIDTCONSULTING-GROUP,INC.
MECHANICAL ELECTRICAL STRUCTURAL COMMU NICATIONS I INDUSTRIAL
P: 893-4380093 F: 8934 32-863T02
STUART SMITH P.E. FLORIDA LICENSE NUMBER 49738
SC G PROJECT: 2015-176
CMU WALL NOTES:
1. DOWEL ALL CMU REINFORCING IN FOOTINGS AND EXTEND INTO UPPERMOST BOND BEAM WITH 90° HOOKS WITH A MINIMUM T-O" LEG.
2. CELLS AROUND REINFORCING ARE TO BE FILLED WITH 3000 PSI GROUT.3. PROVIDE FOUR (4) FILLED CELLS OF TYPICAL WALL REINFORCING AT
INTERSECTIONS. PROVIDE THREE (3) FILLED CELLS OF TYPICAL WALL REINFORCING AT ALL WALL CORNERS. PROVIDE TOO (2) FILLED CELLS AT EACH SIDE OF WALL OPENINGS AND AT DISCONTINUOUS ENDS.
4. ALL CONCRETE MASONRY UNITS SHALL BE PU\CED IN RUNNING BOND.5. TYPICAL WALL REINFORCING UNLESS OTHERWISE NOTED WITH ADDITIONAL
REINFORCING IN NOTE 3:A. EXTERIOR WALLS:
(1) VERTICAL REINF. IN 8" BLOCK SHALL BE #5 @ 32" O.C. w/ ADDITIONAL INDICATED IN NOTE 3.
B. INTERIOR WALLS:(1) VERTICAL REINFORCING IN 8" BLOCK SHALL BE #5 @ 48", WITH
ADDITIONAL REINFORCING AS INDICATED IN NOTE 3. HORIZONTAL REINFORCING IN ALL BLOCK WALLS SHALL BE HEAVY DUTY (3/16 SIDE RODS WITH 9 GAUGE CROSS RODS) LADDER TYPE WALL REINFORCING AT 16" U.N.O. ALL WALLS PERPENDICUU\R TO EXTERIOR WALLS SHALL HAVE ADDITIONAL PREFABRICATED "T" OR "L" JOINT REINFORCING IN ALTERNATE BLOCK AS INDICATED IN TYPICAL CMU DETAILS.HORIZONTAL JOINT REINFORCING IN MASONRY CAVITY WALLS SHALL BE HEAVY DUTY (3/16 SIDE RODS W/ 9 GAUGE CROSS RODS) LADDER TYPE WALL REINFORCING W/ ADJUSTABLE U-SHAPED PINTLE EYE VENEER TIES FABRICATED OF 3/16 INCH DIAMETER HOT DIPPED GALV STEEL WIRE SPACED @ 16" O.C. MAXIMUM ECCENTRICITY BETOEEN EACH ELEMENT OF THE TIE IS 1/2 INCH. JOINT REINFORCING SHALL BE AT 16" O.C. VERTICALLY W/ 8" O.C. VERTICALLY AT BUILDING CORNERS (SEE WIND CLADDING DIAGRAM FOR CORNER DIMENSIONS.) TIES SHALL BE WITHIN 8" OF WALL DISCONTINUITIES (MCJ, DOORS, WINDOWS, ETC.)PROVIDE HORIZONTAL BOND BEAMS AT 10‘-0" O.C. MAXIMUM VERTICALLY:8" CMU BOND BEAM SHALL BE REINFORCED WITH 2#5 CONT.GROUT STOP IS A FIBERGLASS MESH CONFORMING TO ASTM STANDARD D1668-73, TYPE 207.PROVIDE MINIMUM 8" DEEP CONCRETE CAP BEAM AT TOP OF ALL BEARING WALLS OR WALLS TO ROOF DECK, MINIMUM REINFORCING AS FOLLOWS:
C.
D.
E.
F,
G.
(1) 8" WALLS SHALL HAVE 2-#5 CONT.H. PROVIDE MINIMUM 8" CMU CAP BEAM AT TOP OF ALL NON-BEARING
WALLS WITH 2 #5 CONT., TOP.(1) 8" WALLS SHALL HAVE 2-#5 CONT.
I. SPLICE ALL BARS 48 BAR DIAMETERS UNLESS NOTED OTHERWISE. 6. IN WALL PILASTERS SHALL BE 4 FILLED CELLS WITH #5 EACH CELL, TYP.
1. DOWEL ALL CMU REINFORCING IN FOOTINGS AND EXTEND INTO UPPERMOSTBOND BEAM WITH 90º HOOKS WITH A MINIMUM 1'-0" LEG.
2. CELLS AROUND REINFORCING ARE TO BE FILLED WITH 3000 PSI GROUT.3. PROVIDE FOUR (4) FILLED CELLS OF TYPICAL WALL REINFORCING AT
INTERSECTIONS. PROVIDE THREE (3) FILLED CELLS OF TYPICAL WALLREINFORCING AT ALL WALL CORNERS. PROVIDE TWO (2) FILLED CELLS ATEACH SIDE OF WALL OPENINGS AND AT DISCONTINUOUS ENDS.
4. ALL CONCRETE MASONRY UNITS SHALL BE PLACED IN RUNNING BOND.5. TYPICAL WALL REINFORCING UNLESS OTHERWISE NOTED WITH ADDITIONAL
REINFORCING IN NOTE 3:A. EXTERIOR WALLS:
(1) VERTICAL REINF. IN 8" BLOCK SHALL BE #5 @ 32" O.C. w/ ADDITIONAL INDICATED IN NOTE 3.
B. INTERIOR WALLS: (1) VERTICAL REINFORCING IN 8" BLOCK SHALL BE #5 @ 48", WITH ADDITIONAL REINFORCING AS INDICATED IN NOTE 3.
C. HORIZONTAL REINFORCING IN ALL BLOCK WALLS SHALL BE HEAVY DUTY (3/16 SIDE RODS WITH 9 GAUGE CROSS RODS) LADDER TYPE WALL REINFORCING AT 16" U.N.O. ALL WALLS PERPENDICULAR TO EXTERIOR WALLS SHALL HAVE ADDITIONAL PREFABRICATED "T" OR "L" JOINT REINFORCING IN ALTERNATE BLOCK AS INDICATED IN TYPICAL CMU DETAILS.
D. HORIZONTAL JOINT REINFORCING IN MASONRY CAVITY WALLS SHALL BE HEAVY DUTY (3/16 SIDE RODS W/ 9 GAUGE CROSS RODS) LADDER TYPE WALL REINFORCING W/ ADJUSTABLE U-SHAPED PINTLE EYE VENEER TIES FABRICATED OF 3/16 INCH DIAMETER HOT DIPPED GALV STEEL WIRE SPACED @ 16" O.C. MAXIMUM ECCENTRICITY BETWEEN EACH ELEMENT OF THE TIE IS 1/2 INCH. JOINT REINFORCING SHALL BE AT 16" O.C. VERTICALLY W/ 8" O.C. VERTICALLY AT BUILDING CORNERS (SEE WIND CLADDING DIAGRAM FOR CORNER DIMENSIONS.) TIES SHALL BE WITHIN 8" OF WALL DISCONTINUITIES
(MCJ, DOORS, WINDOWS, ETC.)E. PROVIDE HORIZONTAL BOND BEAMS AT 10'-0" O.C. MAXIMUM
VERTICALLY:8" CMU BOND BEAM SHALL BE REINFORCED WITH 2#5 CONT.
F. GROUT STOP IS A FIBERGLASS MESH CONFORMING TO ASTM STANDARD D1668-73, TYPE 207.
G. PROVIDE MINIMUM 8" DEEP CONCRETE CAP BEAM AT TOP OF ALL BEARING WALLS OR WALLS TO ROOF DECK, MINIMUM REINFORCING AS FOLLOWS:
(1) 8" WALLS SHALL HAVE 2-#5 CONT.H. PROVIDE MINIMUM 8" CMU CAP BEAM AT TOP OF ALL NON-BEARING
WALLS WITH 2 #5 CONT., TOP.(1) 8" WALLS SHALL HAVE 2-#5 CONT.
I. SPLICE ALL BARS 48 BAR DIAMETERS UNLESS NOTED OTHERWISE.6. IN WALL PILASTERS SHALL BE 4 FILLED CELLS WITH #5 EACH CELL, TYP.
UNDER GIRDERS.
USE PREFABRICATED "T" AND "L"JOINT REINFORCING SHAPES ATCORNERS AND INTERSECTIONS.PROVIDE MINIMUM LENGTHS ASINDICATED.
4 SEE PLA% -V STUART SMITH P.E. FLORIDA LICENSE NUMBER 49738
- X I -- X~j,---------------------------- ^ --- ------ «--X- -X — X—— X — X — X E=? 1
-- ---- 1 * ■' I---- •---- 1
X--------- X—<xUJ <W 5^
F.F.E. F.F.E. 1CD r-o 'j SC G PROJECT: 2015-176•:.«-SLAB i ?BULKHEAD TO FOLLOW
METAL DECK FLUTE PROFILE.T.O.S.
s?REINFORCING s 5O 0 5b! ^
O 0
O 0NOTES:
7SEE PLANS FOR BEAM SIZES
PROVIDE GIRDER FILLER DECK ACCESSORIES AS REQUIRED
SHEAR CONNECTION TYP., SEE SCHEDULE
1. CONSTRUCTION JOINTS PARALLEL TO DECK FLUTES SHALL BE LOCATED NO
CLOSER THAN 5'-0" FROM THE CENTER LINE OF THE NEAREST GIRDER.
2. CONSTRUCTION JOINTS PERPENDICULAR TO DECK FLUTES SHALL BE LOCATED
AT THE CENTER LINE OF THE METAL DECK SPAN.
3. AT THE CONTRACTOR’S OPTION. PREFORMED METAL SHEAR KEY FOLLOWING
CONTOUR OF METAL DECK FLUTES MAY BE USED WITH SLAB REINFORCING STOPPING EACH SIDE AND #3 DOWELS x2'-0"(C ENTE RED ON JOINT) AT 18" O.C.
BEAM, SEE PLAN
CONT. GIRDER, SEE PLANCOMPOSITE STUD NOTES:
1. TYPICAL HEADED STUDS USED FOR COMPOSITE STEEL CONSTRUCTION SHALL BE 3/4"0x4", UNLESS NOTED OTHERWISE BY SPECIFIC FRAMING CONDITION AND/OR SECTIONS & DETAILS.+WELD STUDS TO STEEL BEAMS AND GIRDERS UNDER DRY CONDITIONS IN ACCORDANCE WITH AWS D-1.1 AND THE LATEST OSHA REQUIREMENTS. STUDS MAY BE WELDED THROUGH BOTTOM RIBS OF COMPOSITE STEEL DECK ATTACHED AND IN DIRECT CONTACT WITH SUPPORTING STEEL BEAMS OR GIRDERS.DO NOT WELD STUDS TO CONTINUOUS EDGE PLATES OR FILLER PLATES UNLESS SPECIFICALLY DETAILED ON THE CONSTRUCTION DOCUMENTS. STUD INSTALLATION SHALL PROVIDE A MINIMUM OF 1" CONCRETE CLEAR COVER ABOVE THE TOP OF STUD; AND 1" LATERAL CONCRETE CLEAR COVER EACH SIDE OF STUD UNLESS THE STUD IS INSTALLED IN THE DECK RIBS.REFER TO THE TYPICAL COMPOSITE STEEL CONSTRUCTION DETAIL FOR ADDITIONAL STUD INSTALLATION REQUIREMENTS.
2.1. PROVIDE SUPPORT CHAIRS AND ACCESSORIES TO PLACE SLAB REINFORCEMENT AT THE SPECIFIED LOCATION WITHIN THE SLAB THICKNESS.REFER TO STRUCTURAL NOTES FOR REINFORCING LAP SPLICE REQUIREMENTS.REFER TO SECTIONS AND DETAILS FOR ADDITIONAL SLAB REINFORCING AT THE SLAB EDGE AND OPENING CONDITIONS.COORDINATE SLAB REINFORCING PLACEMENT WITH CONSTRUCTION JOINT LOCATIONS. REFER TYPICAL CONSTRUCTION JOINT DETAILS.
TYP. ELEVATED SLAB CONST. JT DETAIL0 3.
3/4" = 1'-0" 2.
4.3.
5.CONNECT OVERLAPPED SIDE LAPS W/ #10 HEX HEAD SELF-DRILLING SELF TAPPING SCREWS.
4.C
5 6.
Y£LLULU
TYPICAL COMPOSITE SLAB AT GIRDER
TYPICAL COMPOSITE STUD DETAIL
V)ELEVATION
V S50(W \s5ooyzfc NTS NTSI I I
COMPOSITE STEEL DECK
I j-
\ ! .5/8"0 PUDDLE WELD OR APPROVED MECHANICAL FASTENER, TYP U.N.O.
* tY A
—L XX
t I •7
I
EDGE OFCOMPOSITE DECK
I——L ONE LAYER OF W.W.F., INSTALL 1" FROM TOP OF
SLAB, SEE PLAN FOR SIZE
<t CONSTRUCTION JOINTCOLLCOL 1/4 OF BEAM SPAN r-6"<L BEAMÇ. BEAM
1 ' - 0"PARTIAL PLAN PROVIDE CLOSURE OVER GAP IN DECK AS REQUIRED.
cd EXTENDW.W.F.
B SEE PLAN O EXTEND W.W.F.I SEE PLAN ASEE PLAN,> •. - 7 xt 4? i ! wmmi;X--------X-------- ±xUJ I X--------- X
T T hV) &CL& T T.O.S. $ < sT.O.S.2" (MIN.) DECK BEARING (PROVIDE 1/4"x5" CONT. PLATE WELDED TO BEAM FOR BEAM FLANGE WIDTHS LESS
INTERMEDIATESTRUCTURAL
SUPPORT
STRUCTURAL SUPPORTAT
END OF SHEET.
7 0 oCOMPOSITE BEAM, SEE PLAN DECK 0 o
0 oFLOOR BEAM FLOOR BEAM
EQ EQBEAM £ BEAM THAN 5"),SECTION GIRDER FLOOR BEAM
COMPOSITE SLAB STEEL REINFORCING INSTALLATION NOTES: ç CONSTRUCTION JOINT
DECK INSTALLATION NOTES: ^ GIRDER
1. PROVIDE SUPPORT CHAIRS AND ACCESSORIES TO PLACE SLAB REINFORCEMENT AT THE SPECIFIED LOCATION WITHIN THE SLABTHICKNESS.REFER TO GENERAL STRUCTURAL NOTES FOR REINFORCING LAP SPLICE REQUIREMENTS.REFER TO SECTIONS AND DETAILS FOR ADDITIONAL SLAB REINFORCING AT THE SLAB EDGE AND OPENING CONDITIONS. COORDINATE SLAB REINFORCING PU\CEMENT WITH CONSTRUCTION JOINT LOCATIONS. REFER TYPICAL CONSTRUCTION JOINT DETAILS.
1. SEE PLAN FOR SIZE AND GAUGE OF GALVANIZED COMPOSITE STEEL DECK. THE DECK SHALL BE FASTENED TO SUPPORT FRAMING BY 5/8"0 PUDDLE WELDS OR APPROVED MECHANICAL FASTENERS AT THE FOLLOWING LOCATIONS: -AT SHEET ENDS, FASTEN BETOEEN EACH RIB AND EACH SIDE OF SIDE U\PS -AT INTERMEDIATE STRUCTURAL SUPPORTS, FASTEN BETOEEN ALTERNATE RIBS OR AT 12" O.C. (WHICHEVER RESULTS IN THE SMALLEST SPACING) AND EACH SIDE OF SIDE LAPS. -AT SIDE SUPPORTS, FASTEN AT 12" O.C.OVERLAPPED SIDE LAPS BETOEEN STRUCTURAL SUPPORTS SHALL BE FASTENED BY #10 SELF DRILLING SCREWS SPACED MIDWAY BETOEEN THE STRUCTURAL SUPPORTS BUT NOT MORE THAN 3'-0" O.C.PROVIDE ADDITIONAL DECK ACCESSORIES SUCH AS COLUMN CLOSURES, CELL CLOSURES, AND GIRDER FILLERS AS REQUIRED TO COMPLETE THE FLOOR DECK ASSEMBLY. THE THICKNESS OF SUCH ADDITIONAL ACCESSORIES SHALL NOT BE LESS THAN THE SPECIFIED DECK GAUGE.
INSTALLATION NOTES:2. INSTALLATION NOTES:
1. OBTAIN APPROVAL FROM ENGINEER FOR PROPOSED LOCATIONS, PRIOR TO CONSTRUCTION.
2.1. LOCATE CONSTRUCTION JOINTS PARALLEL WITH FLOOR
BEAMS IN THE FIRST DECK SPAN ADJACENT TO COLUMN LINE.2. OBTAIN APPROVAL FROM ENGINEER FOR PROPOSED
LOCATIONS, PRIOR TO CONSTRUCTION.
3.
4.
3.
A 4.
COMPOSITE DECK INSTALLATION
TYPICAL COMPOSITE SLAB AT BEAM
COMPOSITE SLAB CONSTRUCTION JOINT PARALLEL W/BEAMS
COMPOSITE SLAB CONSTRUCTION JOINT PARALLEL W/ GIRDERS&
\S500 J v S50(y \s5ooy v ssolyNTS NTS NTS NTS
SHEETIDENTIFICATION
S500
MUS Army Corps of Engineers ® Mobile District
Vma
rk
I
^ddvl
FILE
NA
ME:
S5
00ES
13.D
WG
I SIZ
E:I A
NSI
DD
ATE
DES
CR
IPTI
ON
MA
RK
APP
R.
DA
TED
ESC
RIP
TIO
N
BULL
OC
K TI
CE
ASSO
CIA
TES
909
E. C
ERVA
NTE
S ST
REE
T, S
UIT
E B.
PE
NSA
CO
LA, F
LOR
IDA
PLO
T D
ATE
: 08
FEB
, 201
7PR
OJE
CT
NU
MB
ER:
M01
5ES1
31:
1
I PLO
T SC
ALE
:ST
EEL
DET
AIL
SSU
BM
ITTE
D B
Y:
S.SM
ITH
CO
NTR
ACT
NO
.:
U.S
. AR
MY
CO
RPS
OF
ENG
INEE
RS
M
OB
ILE
DIS
TRIC
T M
OB
ILE
, ALA
BAM
AC
KD
BY:
S.
SM
ITH
DW
N B
Y:
J.K
ELLY
SOLI
CIT
ATI
ON
NO
.: W
9127
8-17
-R-0
010
FY16
AD
DIT
ION
TO
39
IOS
FAC
ILIT
Y
HU
RLB
UR
T FI
ELD
, FLO
RID
A
DA
TE:
FEB
RUAR
Y 8,
201
7I D
ESIG
NED
BY:
IS
.SM
ITH
F.F.E.SEE PLAN
T.O.S.
PLAN
SEE
1-1/
2" M
IN.
3/4" HEADED STUD,SEE NOTES BELOW
COMPOSITE 2"STEEL DECK
BEAM ,SEE PLAN
COMPOSITE STUD NOTES:
1. TYPICAL HEADED STUDS USED FOR COMPOSITE STEEL CONSTRUCTIONSHALL BE 3/4"Øx4", UNLESS NOTED OTHERWISE BY SPECIFIC FRAMINGCONDITION AND/OR SECTIONS & DETAILS.+
2. WELD STUDS TO STEEL BEAMS AND GIRDERS UNDER DRY CONDITIONS INACCORDANCE WITH AWS D-1.1 AND THE LATEST OSHA REQUIREMENTS.
3. STUDS MAY BE WELDED THROUGH BOTTOM RIBS OF COMPOSITE STEELDECK ATTACHED AND IN DIRECT CONTACT WITH SUPPORTING STEELBEAMS OR GIRDERS.
4. DO NOT WELD STUDS TO CONTINUOUS EDGE PLATES OR FILLER PLATESUNLESS SPECIFICALLY DETAILED ON THE CONSTRUCTION DOCUMENTS.
5. STUD INSTALLATION SHALL PROVIDE A MINIMUM OF 1" CONCRETE CLEARCOVER ABOVE THE TOP OF STUD; AND 1" LATERAL CONCRETE CLEARCOVER EACH SIDE OF STUD UNLESS THE STUD IS INSTALLED IN THEDECK RIBS.
6. REFER TO THE TYPICAL COMPOSITE STEEL CONSTRUCTION DETAIL FORADDITIONAL STUD INSTALLATION REQUIREMENTS.
1" M
IN.
TO W
.W.F
.1"
CLR
SEE PLAN
TO #
4 1
1/2"
CLR
#4x8'-0" @18" O.C.CENTERED OVER
GIRDER
SEE PLAN FOR SLAB &DECK INFORMATION,TYP.
PROVIDE GIRDER FILLERDECK ACCESSORIESAS REQUIREDSHEAR CONNECTION TYP.,SEE SCHEDULE
1. OBTAIN APPROVAL FROM ENGINEER FORPROPOSED LOCATIONS, PRIOR TOCONSTRUCTION.
COL
SEE PLAN
T.O.S.
EQ EQ
1' - 0"
EXTEND W.W.F.
1" C
LR.
PLAN
SEE
FLOOR BEAMDECK
INSTALLATION NOTES:
1. LOCATE CONSTRUCTION JOINTS PARALLEL WITH FLOORBEAMS IN THE FIRST DECK SPAN ADJACENT TO COLUMN LINE.
2. OBTAIN APPROVAL FROM ENGINEER FOR PROPOSEDLOCATIONS, PRIOR TO CONSTRUCTION.
CONSTRUCTIONJOINT
BEAMCOL
FLOOR BEAM
DECK INSTALLATION NOTES:
1. SEE PLAN FOR SIZE AND GAUGE OF GALVANIZED COMPOSITE STEEL DECK.2. THE DECK SHALL BE FASTENED TO SUPPORT FRAMING BY 5/8"Ø PUDDLE
WELDS OR APPROVED MECHANICAL FASTENERS AT THE FOLLOWINGLOCATIONS: -AT SHEET ENDS, FASTEN BETWEEN EACH RIB AND EACHSIDE OF SIDE LAPS -AT INTERMEDIATE STRUCTURAL SUPPORTS, FASTENBETWEEN ALTERNATE RIBS OR AT 12" O.C. (WHICHEVER RESULTS IN THESMALLEST SPACING) AND EACH SIDE OF SIDE LAPS. -AT SIDE SUPPORTS,FASTEN AT 12" O.C.
3. OVERLAPPED SIDE LAPS BETWEEN STRUCTURAL SUPPORTS SHALL BEFASTENED BY #10 SELF DRILLING SCREWS SPACED MIDWAY BETWEEN THESTRUCTURAL SUPPORTS BUT NOT MORE THAN 3'-0" O.C.
4. PROVIDE ADDITIONAL DECK ACCESSORIES SUCH AS COLUMN CLOSURES,CELL CLOSURES, AND GIRDER FILLERS AS REQUIRED TO COMPLETE THEFLOOR DECK ASSEMBLY. THE THICKNESS OF SUCH ADDITIONALACCESSORIES SHALL NOT BE LESS THAN THE SPECIFIED DECK GAUGE.
SEE
PLAN
CONNECT OVERLAPPEDSIDE LAPS W/ #10 HEXHEAD SELF-DRILLINGSELF TAPPING SCREWS.
NOTES:1. CONSTRUCTION JOINTS PARALLEL TO DECK FLUTES SHALL BE LOCATED NO
CLOSER THAN 5'-0" FROM THE CENTER LINE OF THE NEAREST GIRDER.2. CONSTRUCTION JOINTS PERPENDICULAR TO DECK FLUTES SHALL BE LOCATED
AT THE CENTER LINE OF THE METAL DECK SPAN.3. AT THE CONTRACTOR'S OPTION. PREFORMED METAL SHEAR KEY FOLLOWING CONTOUR OF METAL DECK FLUTES MAY BE USED WITH SLAB REINFORCING STOPPING EACH SIDE AND #3 DOWELS x2'-0"(CENTERED ON JOINT) AT 18" O.C.
REMOVABLE VERTICAL FORMEDBULKHEAD SET IN LOWER FLUTE.
BULKHEAD MUST EXTEND FULL DEPTHOF SLAB WITH SLAB REINFORCING
EXTENDING THRU IT.
SLABREINFORCING BULKHEAD TO FOLLOW
METAL DECK FLUTE PROFILE.
1" C
LR M
IN.
SEE PLAN
F.F.E.
CONSULTING GROUP,INC.
901 W. Garden St. Pensacola, FL 32502P: 850-438-0050 F: 850-432-8631
V —n li=PROVIDE POUR STOP DECK ACCESSORY AT OPENING PERIMETERZs
?z r-o"Y
BAR 1/8"x3"x3'-0" WELD TO TOP OF DECK RIBS
MAX.
U Kl
ftPARTIAL PLAN
INSTALLATION NOTES:
1. DETAIL APPLIES TO TYPICAL SMALL DECK OPENINGS NOT EXCEEDING T- 0" MEASURED PERPENDICULAR TO DECK SPAN (TRANSVERSE TO DECK FLUTES) UNLESS NOTED OTHERWISE.DECK OPENINGS ARE TO BE FABRICATED SO THAT DECKING RUNS CONTINUOUSLY OVER OPENING BEFORE AND AFTER CONCRETE PLACEMENT. THE OPENINGS IN THEDECK ARE NOT TO BE CUT UNTIL OPENING IS NEEDED (PER OSHA). PROVIDE DECK SHORING AT MIDSPAN OR PERIMETER FRAME IF ANY VERTICAL FLUTES ARE CUT PRIOR TO CONCRETE PLACEMENT. CONCRETE FILL NOT SHOWN FOR CLARITY.TAKE CARE TO NOT BURN THROUGH DECK WHEN WELDING PLATE TO DECK. WELDING SHOULD ONLY BE DONE BY A WELDER EXPERIENCED IN WELDING LIGHT GAUGE STEEL
2.
3.
4.5.
x<r-o11
TYP. REINFORCING AT SMALL OPENINGS IN COMPOSITE SLABft
V S501J NTS
0 8" r-4" 2'-8"
SCALE: 3/4"= 1'-0"
D
C
MIN. OF 1 STUD PER SIDE FOR RECTANGULAR OPENING
3/16" BENT PLATE (SEE NOTES 2 & 3) W/ 5/8"0xO'-6" STUDS @ 24" O.C. TYP.
/ ?—*—*-i
HILTI 0.1450 X-EDNI FASTENERS @6" O.C. MAX., TYP.2-#4 BOTTOM EACH SIDE OF
OPENING, EXTEND 24"MIN. BEYOND OPENING AND TO
ADJACENT FL. BEAMS1'-0"~2'~6" MAX.B
SEE NOTES
Jf———x' ^x^-x- X;ftftHILTI 0.1450 X-EDNI
FASTENERS @6" O.C.MAX., TYP.
NOTES:
1. SEE OTHER DETAILS FOR ADDITIONAL REQUIREMENTS AT LARGE OPENINGS IN SLABS.2. BEND 3/16" PU\TE TO RADIUS AROUND CIRCULAR OPENINGS.3. ALTERNATE TO 3/16" PLATE; USE PREFORMED 14 GAGE MIN. SLEEVES PROVIDING ANCHORAGE TO CONCRETE AT TOP AND BOTTOM OF SLAB.
3" 3"
1/8I/
r-011 TO 2'-6"
ftV S501J
TYP ELEVATED SLAB @ OPENING DETAIL3/4" = T-0"
A
MUS Amy Corps of Engineers ® Mobile DistrictSCHMIDT
NOTES:1. SEE OTHER DETAILS FOR ADDITIONAL REQUIREMENTS AT LARGE OPENINGS IN SLABS.2. BEND 3/16" PLATE TO RADIUS AROUND CIRCULAR OPENINGS.3. ALTERNATE TO 3/16" PLATE; USE PREFORMED 14 GAGE MIN. SLEEVES PROVIDING ANCHORAGE TO CONCRETE AT TOP AND BOTTOM OF SLAB.
2-#4 BOTTOM EACH SIDE OFOPENING, EXTEND 24"MIN.BEYOND OPENING AND TO
ADJACENT FL. BEAMS
MIN. OF 1 STUD PER SIDEFOR RECTANGULAROPENING
3/16" BENT PLATE (SEE NOTES2 & 3) W/ 5/8"Øx0'-6" STUDS@ 24" O.C. TYP.
PROVIDE POUR STOPDECK ACCESSORY ATOPENING PERIMETER
BAR 1/8"x3"x3'-0"WELD TO TOPOF DECK RIBS
INSTALLATION NOTES:
1. DETAIL APPLIES TO TYPICAL SMALL DECK OPENINGS NOT EXCEEDING 1'-0" MEASURED PERPENDICULAR TO DECK SPAN (TRANSVERSE TODECK FLUTES) UNLESS NOTED OTHERWISE.
2. DECK OPENINGS ARE TO BE FABRICATED SO THAT DECKING RUNSCONTINUOUSLY OVER OPENING BEFORE AND AFTER CONCRETEPLACEMENT. THE OPENINGS IN THEDECK ARE NOT TO BE CUT UNTIL OPENING IS NEEDED (PER OSHA).
3. PROVIDE DECK SHORING AT MIDSPAN OR PERIMETER FRAME IF ANYVERTICAL FLUTES ARE CUT PRIOR TO CONCRETE PLACEMENT.
4. CONCRETE FILL NOT SHOWN FOR CLARITY.5. TAKE CARE TO NOT BURN THROUGH DECK WHEN WELDING PLATE TO
DECK. WELDING SHOULD ONLY BE DONE BY A WELDER EXPERIENCED INWELDING LIGHT GAUGE STEEL
PARTIAL PLAN
X < 1'-0"
CONSULTING GROUP,INC.
901 W. Garden St. Pensacola, FL 32502P: 850-438-0050 F: 850-432-8631
GIRDER, SEE PLAN SHEAR CONNECTION, SEE SCHEDULE, TYP.
SEE PLAN SEE PLAN SEE PLANCOLUMN, SEE PLAN t I COLUMN, SEE PLAN[3]* (NOTE 4) [10]
t BEAM t BEAMCOMPOSITE BEAM STUD INSTALLATION NOTES:
COMPOSITE GIRDER ELEVATION1. INSTALL STUDS CENTERED IN THE DECK RIB ALONG THE
CENTERLINE OF THE BEAM NO LESS THAN 1" FROM EDGES OF BEAM FU\NGES AND ENDS.[#] INDICATES TOTAL NUMBER OF STUDS REQUIRED PER BEAM AS SHOWN ON THE FRAMING PU\NS.STUD DISTRIBUTION ALONG THE BEAM LENGTH SHALL BE 1, 2, OR 3 STUDS PLACED IN THE LOW RIBS OF COMPOSITE DECK CENTERED ON THE BEAM FLANGE WIDTH TO ACHIEVE THE REQUIRED STUD QUANTITY.FOR BEAMS SUPPORTING COMPOSITE FLOOR DECK THAT DO NOT SHOW THE [#] OF STUDS REQUIRED, INSTALL STUDS AT 3'-0" O.C. MAXIMUM SPACING.*FOR CANTILEVERED BEAMS, INSTALL STUDS ONLY ON THE BACKS PAN.EXAMPLES OF A UNIFORM STUD LAYOUT FOR A BEAM WITH 11 RIBS PER SPAN: (NUMBERS = # STUDS PER RIB). TYPICAL DISTRIBUTION OF THE REQUIRED STUDS IS SYMMETRICAL ABOUT CENTERLINE OF BEAM SPAN AS SHOWN BELOW:
2.
COL 3.VARIES
SEE PLANcn cn OID Ë O'
CO LUi— Q_
CDLU 4.00
o_CNICOMPOSITE STEEL DECK 5.
ZZL
3 6.NOTE:UJCD TYPICAL STUD PLACEMENT
IS CENTERED WITHIN EACH LOW RIB£&'h
i 3
EDGE OF BEAM FLANGE BELOW [9] 111110
111111 2 2 2 1 1 13 3 2 2 2 2
1* 0 1 1 11I I[11] 1 1 1 1 1 1
-EQ I I I
yytECK VEQ
[17] 1 112 2 2 2 2 2 3 3
PROVIDE COLUMN FILLER DECK
ACCESSORY AS REQUIRED
1 ■ - 0" [28] 2PARTIAL PLANT 7*
MAX MIN3' - 0"* PROVIDE GIRDER
FILLER DECK ACCESSORY AS
REQUIRED —x
I I SEE PLAN FOR SLAB & DECKMAX
\ I ISEE PLAN
m 1» a! —^ . r
v2 » V
/—v H r• --
A- T.O.S.
t$
COMPOSITE STEEL DECK, SEE PLAN FOR SIZE AND GAUGE
FLOOR BEAM, SEE PLAN
SHEAR CONNECTION, SEE SCHEDULE, TYP.rCOLUMN,
SEE PLAN FLOOR GIRDER, SEE PLAN
^ COLUMN ‘t GIRDERCOMPOSITE BEAM ELEVATION
'VSEE PL^N
UJ §
» o2T.O.S.
s
llCOLUMN WEB
T
t COLUMN t GIRDERCAMBERED BEAM ELEVATION
STEEL FRAMING CAMBER REQUIREMENTS: CONCRETE PLACEMENT OVER CAMBERED STEEL FRAMING:
1. DETAIL APPLIES TO BEAMS AND GIRDERS REQUIRING CAMBER AS SHOWN ON THE FRAMING PLANS.
2. FOR SIMPLY SUPPORTED BEAMS AND GIRDERS, CAMBER SHALL BE INDUCED SUCH THAT A PARABOLIC CURVED PROFILE IS ACHIEVED TO THE SPECIFIED AMOUNT MEASURED AT MIDSPAN. CAMBER INDUCED BY HEAT OR FORCE APPLIED AT SINGLE POINT IS PROHIBITED.
3. FOR CANTILEVERED BEAMS AND GIRDERS, CAMBER IS MEASURED AT THE END OF THE CANTILEVERED MEMBER APPROXIMATING A LINEAR PROFILE MEASURED FROM THE SPECIFIED TOP OF STEEL AT SUPPORTING BEAM, GIRDER, OR COLUMN. SUPPORTING CONNECTIONS SHALL BE FABRICATED SUCH THAT THE SPECIFIED CAMBER AT THE END OF THE MEMBER IS ACHIEVED.
1. THE CONTRACTOR SHALL SUBMIT SU\B CONSTRUCTION JOINT LOCATIONS TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO CONCRETE PLACEMENT.CONCRETE SHALL BE PLACED OVER COMPOSITE DECK. TO THE SPECIFIED MIN. THICKNESS REQUIRED ON PLANS. BEAMS AND GIRDERS HAVE BEEN SIZED TO ACCOMMODATE UP TO 10% ADDITIONAL CONCRETE SLAB THICKNESS (MEASURED AT MIDSPAN) IF NECESSARY TO PROVIDE A LEVEL FINISH FLOOR SURFACE.
2.
3.
COLVARIES
SEE PLAN002 COMPOSITE GIRDER STUD INSTALLATION NOTES:*2
CXI 00
O'2 V? O
1. INSTALL STUDS NO LESS THAN 1" FROM EDGES OF GIRDER FLANGES AND ENDS.STUD INSTALLATION FOR STEEL GIRDERS MAY BE EITHER UNIFORM OR SEGMENTED AS SHOWN ON THE FRAMING PU\NS. [#] AFTER THE GIRDER SIZE DESIGNATION INDICATED THE NUMBER OF STUDS REQUIRED FORA UNIFORM STUD INSTALLATION. REFER TO COMPOSITE BEAM STUD INSTALLATION DETAIL ILLUSTRATED.FOR GIRDERS REQUIRING A SEGMENTED (NON-UNIFORM) STUD INSTALLATION: THE [#] OF STUDS REQUIRED ARE INDICATED BELOW THE GIRDER DESIGNATION BETOEEN EACH OF THE CONNECTED BEAMS FRAMING INTO THE GIRDER AS SHOWN ON THE PLANS. STUD INSTALLATION SHALL BE EVENLY SPACED ALONG THE SEGMENTED GIRDER LENGTH IN A EITHER A SINGLE ROW, 2 STAGGERED ROWS, OR 2 ROWS TO ACHIEVE THE REQUIRED [#] STUDS INSTALLED WITHIN THE GIRDER SEGMENT. AN EXAMPLE OF SEGMENTED STUD INSTALLATION IS ILLUSTRATED.FOR GIRDERS SUPPORTING COMPOSITE FLOOR DECK THAT DO NOT SHOW THE [#] OF STUDS REQUIRED, PROVIDE STUDS SPACED AT 36" ON CENTER MAXIMUM.*FOR CANTILEVERED GIRDERS, INSTALL STUDS ONLY ON THE BACKSPAN.
2 2cxi CD
2.
CDUJ
CM
4 o2^- 3.--------5 _
it COMPOSITE STEEL DECK
PARTIAL PLAN4.
6" 4-1/2" MIN. SPACING 6"7f
36" MAX. SPACINGCOLUMN FILLER DECK ACCESSORY
AS REQUIRED
5.
SEE PLAN FOR SLAB & DECK
SEE PLm I I
f-'T-HTIA- T.O.S.
SHEETIDENTIFICATION
V S503 VTYPICAL COMPOSITE STEEL CONSTRUCTION ft
V S503 VTYPICAL CAMBERED STEEL CONSTRUCTION
S503NTS NTS
MUS Amy Corps of Engineers ® Mobile District
1 2 3 4 5
D
C
B
A
T
SPE
CIF
IED
C
AMBE
R,
SE
E P
LAN
I-f-X
blab
th
ick
ne
ss
NIIA
I
Vmar
kJ
^ddvl
FILE
NA
ME
: S
503E
S13
.DW
GI S
IZE:
I AN
SI D
DAT
ED
ESC
RIP
TIO
NM
ARK
APPR
.D
ATE
DES
CR
IPTI
ON
BULL
OC
K TI
CE
ASSO
CIA
TES
909
E. C
ERVA
NTE
S ST
REE
T, S
UIT
E B.
PE
NSA
CO
LA, F
LOR
IDA
PLO
T D
ATE:
08
FEB
, 201
7P
RO
JEC
T N
UM
BER
: M
015E
S13
1:1
I PLO
T S
CA
LE:
STEE
L D
ETA
ILS
SU
BM
ITTE
D B
Y:
S.SM
ITH
CO
NTR
AC
T N
O.:
U.S
. AR
MY
CO
RPS
OF
ENG
INEE
RS
M
OB
ILE
DIS
TRIC
T M
OB
ILE
, ALA
BAM
AC
KD B
Y:
S. S
MIT
HD
WN
BY:
J.
KE
LLY
SO
LIC
ITA
TIO
N N
O.:
W91
278-
17-R
-001
0
FY16
AD
DIT
ION
TO
39
IOS
FAC
ILIT
Y
HU
RLB
UR
T FI
ELD
, FLO
RID
A
DAT
E:FE
BRU
ARY
8, 2
017
I DE
SIG
NE
D B
Y:
IS.S
MIT
H
EQ EQSEE PLAN
VARIES
SEE PLAN
T.O.S.
PLAN
SEE
COLUMN WEB
COLUMN GIRDER
GIRDER
SEE
P LAN
SPEC
IFIE
D
CAM
BER
,
CAMBEREDBEAM PROFILE
DEFLECTEDBEAM PROFILE
SEE PLAN FORSLAB & DECK(NOT SHOWN)
SHEARCONNECTION,SEE SCHEDULE,TYP.
MIN
.SL
AB T
HIC
KNES
S
CAMBERED BEAM ELEVATION
STEEL FRAMING CAMBER REQUIREMENTS:
1. DETAIL APPLIES TO BEAMS AND GIRDERS REQUIRING CAMBER ASSHOWN ON THE FRAMING PLANS.
2. FOR SIMPLY SUPPORTED BEAMS AND GIRDERS, CAMBER SHALL BEINDUCED SUCH THAT A PARABOLIC CURVED PROFILE IS ACHIEVED TOTHE SPECIFIED AMOUNT MEASURED AT MIDSPAN. CAMBER INDUCEDBY HEAT OR FORCE APPLIED AT SINGLE POINT IS PROHIBITED.
3. FOR CANTILEVERED BEAMS AND GIRDERS, CAMBER IS MEASURED ATTHE END OF THE CANTILEVERED MEMBER APPROXIMATING A LINEARPROFILE MEASURED FROM THE SPECIFIED TOP OF STEEL ATSUPPORTING BEAM, GIRDER, OR COLUMN. SUPPORTINGCONNECTIONS SHALL BE FABRICATED SUCH THAT THE SPECIFIEDCAMBER AT THE END OF THE MEMBER IS ACHIEVED.
CONCRETE PLACEMENT OVER CAMBERED STEEL FRAMING:
1. THE CONTRACTOR SHALL SUBMIT SLAB CONSTRUCTIONJOINT LOCATIONS TO THE ENGINEER FOR REVIEW ANDAPPROVAL PRIOR TO CONCRETE PLACEMENT.
2. CONCRETE SHALL BE PLACED OVER COMPOSITE DECK. TOTHE SPECIFIED MIN. THICKNESS REQUIRED ON PLANS.
3. BEAMS AND GIRDERS HAVE BEEN SIZED TOACCOMMODATE UP TO 10% ADDITIONAL CONCRETE SLABTHICKNESS (MEASURED AT MIDSPAN) IF NECESSARY TOPROVIDE A LEVEL FINISH FLOOR SURFACE.
COL COL
SEE PLAN
VARIES
SEE PLAN
T.O.S.
PLAN
SEE
SEE PLAN
T.O.S.
PLAN
SEE
MIN3"
2 1/
4"
GIRD
ER
6"
36" MAX. SPACING*
4-1/2" MIN. SPACING 6"
BEAM BEAM
COMPOSITESTEEL DECK
PARTIAL PLAN2 S
TUD
ROW
S
1 STU
D RO
W
SEE PLAN FORSLAB & DECK
SHEAR CONNECTION,SEE SCHEDULE, TYP.
COLUMN, SEE PLAN
SHEAR CONNECTION,SEE SCHEDULE, TYP.
GIRDER, SEE PLAN
COLUMN, SEE PLAN
COMPOSITE GIRDER ELEVATION
COMPOSITE GIRDER STUD INSTALLATION NOTES:
1. INSTALL STUDS NO LESS THAN 1" FROM EDGES OF GIRDER FLANGES ANDENDS.
2. STUD INSTALLATION FOR STEEL GIRDERS MAY BE EITHER UNIFORM ORSEGMENTED AS SHOWN ON THE FRAMING PLANS. [#] AFTER THE GIRDERSIZE DESIGNATION INDICATED THE NUMBER OF STUDS REQUIRED FOR AUNIFORM STUD INSTALLATION. REFER TO COMPOSITE BEAM STUDINSTALLATION DETAIL ILLUSTRATED.
3. FOR GIRDERS REQUIRING A SEGMENTED (NON-UNIFORM) STUDINSTALLATION: THE [#] OF STUDS REQUIRED ARE INDICATED BELOW THEGIRDER DESIGNATION BETWEEN EACH OF THE CONNECTED BEAMSFRAMING INTO THE GIRDER AS SHOWN ON THE PLANS. STUD INSTALLATIONSHALL BE EVENLY SPACED ALONG THE SEGMENTED GIRDER LENGTH IN AEITHER A SINGLE ROW, 2 STAGGERED ROWS, OR 2 ROWS TO ACHIEVE THEREQUIRED [#] STUDS INSTALLED WITHIN THE GIRDER SEGMENT. ANEXAMPLE OF SEGMENTED STUD INSTALLATION IS ILLUSTRATED.
4. FOR GIRDERS SUPPORTING COMPOSITE FLOOR DECK THAT DO NOT SHOWTHE [#] OF STUDS REQUIRED, PROVIDE STUDS SPACED AT 36" ON CENTERMAXIMUM.*
5. FOR CANTILEVERED GIRDERS, INSTALL STUDS ONLY ON THE BACKSPAN.
SEE PLAN
[3]* (NOTE 4)
SEE PLAN
[10]
SEE PLAN
COLUMN,SEE PLAN
COLUMN
MAX
1' - 0"
MIN
3"
MAX
3' - 0"*
GIRDER
FLOOR GIRDER,SEE PLAN
COMPOSITE STEEL DECK,SEE PLAN FOR SIZE AND GAUGE
FLOOR BEAM,SEE PLAN
PROVIDE COLUMNFILLER DECK
ACCESSORY ASREQUIRED SEE PLAN FOR
SLAB & DECK
SHEAR CONNECTION,SEE SCHEDULE, TYP.
COMPOSITE BEAM ELEVATION
BEAM
3"
PARTIAL PLAN
NOTE:TYPICAL STUD PLACEMENT
IS CENTERED WITHIN EACH LOW RIB
1 STU
DPE
R RI
B
3 STU
DSPE
R RI
B
2 STU
DSPE
R RI
B
COLUMN FILLERDECK ACCESSORY
AS REQUIRED
COMPOSITESTEEL DECK
COMPOSITE BEAM STUD INSTALLATION NOTES:
1. INSTALL STUDS CENTERED IN THE DECK RIB ALONG THECENTERLINE OF THE BEAM NO LESS THAN 1" FROM EDGESOF BEAM FLANGES AND ENDS.
2. [#] INDICATES TOTAL NUMBER OF STUDS REQUIRED PERBEAM AS SHOWN ON THE FRAMING PLANS.
3. STUD DISTRIBUTION ALONG THE BEAM LENGTH SHALL BE1, 2, OR 3 STUDS PLACED IN THE LOW RIBS OF COMPOSITEDECK CENTERED ON THE BEAM FLANGE WIDTH TOACHIEVE THE REQUIRED STUD QUANTITY.
4. FOR BEAMS SUPPORTING COMPOSITE FLOOR DECK THATDO NOT SHOW THE [#] OF STUDS REQUIRED, INSTALLSTUDS AT 3'-0" O.C. MAXIMUM SPACING.*
5. FOR CANTILEVERED BEAMS, INSTALL STUDS ONLY ON THEBACKSPAN.
6. EXAMPLES OF A UNIFORM STUD LAYOUT FOR A BEAMWITH 11 RIBS PER SPAN: (NUMBERS = # STUDS PER RIB).TYPICAL DISTRIBUTION OF THE REQUIRED STUDS ISSYMMETRICAL ABOUT CENTERLINE OF BEAM SPAN ASSHOWN BELOW:
MECHANICAL ELECTRICAL STRUCTURAL COMMU NICATIONS I INDUSTRIAL
P: 8S3-43S-OOK) F: 853-432-863102
STUART SMITH P.E. FLORIDA LICENSE NUMBER 49738D
SC G PROJECT: 2015-176
HSS COLUMN, SEE PLAN
L4x3 DOUBLE ANGLE CONNECTION, TRIM LEG AS
REQUIRED, 1TP FOR 6", 7", & 8" HSS COLUMNS. PROVIDE
L4X4 FOR 10" HSS COLUMNS
Af'.CL>
4"< 3/4"0 A325-N
BOLTS. SEE TABLE BELOW FOR QUANTITY
3/4"0 A325-N BOLTS, SEE TABLE BELOW FOR QUANTITY
C TYP RETURNI 2W 1 1/2" 1/2"->HSS COLUMN, SEE PLAN
3" I 4" 4 TYP3/4"0 A325-N BOLTS. SEE TABLE
BELOW FOR QUANTITY
*TYp\--------
/ W 1/2'H b!I/ BEAM, SEE PLAN£3 LBEAM, SEE PLANS3 t £_h.
oL4x3 DOUBLE ANGLE CONNECTION, TRIM LEG AS REQUIRED, TYP FOR 6",
7", & 8" HSS COLUMNS. PROVIDE L4X4 FOR 10" HSS COLUMNS
bb T> ?<r b bb b o -itI L4x3-1/2 DOUBLE ANGLE
CONNECTION, SEE TABLE BELOW FOR THICKNESS
S3 hi£3 S33/4"0 A325-N BOLTS, SEE TABLE BELOW
FOR QUANTITY
f f 1 1/2"- L4x3-1/2 DOUBLE ANGLE CONNECTION. SEE TABLE BELOW FOR THICKNESS
L4x3 DOUBLE ANGLE CONNECTION^-1 1/2"HSS COLUMN,
SEE PLAN ■7^BEAM, SEE PLAN I.
FIELD BOLTED SHOP BOLTEDFIELD WELDED SHOP BOLTED
ALL BOLTED DOUBLE ANGLE CONNECTION SCHEDULE
B BOLTED / WELDED DOUBLE ANGLE CONNECTION SCHEDULE
DOUBLE ANGLE MINIMUM THICKNESS
QUANTITY OF 3/4"0 A325-N BOLTS
DOUBLE ANGLE MINIMUM THICKNESS
1TPICAL BEAM SIZEQUANTITY OF BOLTS
FILLETWELD SIZE (W)
CAPACITY(KIPS)
TYPICAL BEAM SIZE
W10, W12 31/4"W10,W12 5/16 3 1/4 48
5/16"W14 35/16" 1/4 48W14 3
5/16"W16 45/16" 1/4 80W16 4
5/16"W18 55/16" 1/4W18 5 115
5/16"W21 65/16" 1/4 150W21 6
3/8"W24, W27 73/8" 5/16 223W24, W27 7
NOTES:NOTES: 1. CONNECTIONS MAY BE FIELD BOLTED OR SHOP BOLTED TO BEAM WEB AT
SUPPLIER’S OPTION.ALL DOUBLE ANGLE CONNECTIONS MUST COMPLY WITH OSHA REGULATIONS. DOUBLE ANGLE CONNECTION OPPOSITE SIDE OF BEAM WEB SHALL HAVE SHORTENED ANGLE AND ONE LESS BOLT. OPPOSITE SIDE WEBS.
1. CONNECTIONS SHALL BE FIELD BOLTED TO BEAM & SHOP WELDED TO HSS COLUMNS.WHEN CONNECTING MEMBER TO PLATE EMBEDS IN CONCRETE, PROVIDE SHORT HORIZONTAL SLOTTED HOLES IN BEAM WEB AND USE L6x3 1/2 DOUBLE ANGLE CONNECTION WITH LONG LEGS OUT.
2.2.
3.
A
VS504 /TYPICAL BEAM TO COLUMN CONNECTION
V S504 /TYPICAL BEAM TO BEAM CONNECTION
NTS NTS
Vmar
kI
'Yiddvj
FILE
NA
ME
: S
504E
S13
.DW
GI S
IZE:
I AN
SI D
DAT
ED
ESC
RIP
TIO
NM
ARK
APPR
.D
ATE
DES
CR
IPTI
ON
BULL
OC
K TI
CE
ASSO
CIA
TES
909
E. C
ERVA
NTE
S ST
REE
T, S
UIT
E B.
PE
NSA
CO
LA, F
LOR
IDA
PLO
T D
ATE:
08
FEB
, 201
7P
RO
JEC
T N
UM
BER
: M
015E
S13
1:1
I PLO
T S
CA
LE:
STEE
L D
ETA
ILS
SU
BM
ITTE
D B
Y:
S.SM
ITH
CO
NTR
AC
T N
O.:
U.S
. AR
MY
CO
RPS
OF
ENG
INEE
RS
M
OB
ILE
DIS
TRIC
T M
OB
ILE
, ALA
BAM
AC
KD B
Y:
S. S
MIT
HD
WN
BY:
J.
KE
LLY
SO
LIC
ITA
TIO
N N
O.:
W91
278-
17-R
-001
0
FY16
AD
DIT
ION
TO
39
IOS
FAC
ILIT
Y
HU
RLB
UR
T FI
ELD
, FLO
RID
A
DAT
E:FE
BRU
ARY
8, 2
017
I DE
SIG
NE
D B
Y:
IS.S
MIT
H
BOLTED / WELDED DOUBLEANGLE CONNECTION SCHEDULE
NOTES:1. CONNECTIONS SHALL BE FIELD BOLTED TO BEAM & SHOP WELDED TO HSS COLUMNS.2. WHEN CONNECTING MEMBER TO PLATE EMBEDS IN CONCRETE, PROVIDE SHORT
HORIZONTAL SLOTTED HOLES IN BEAM WEB AND USE L6x3 1/2 DOUBLE ANGLE CONNECTIONWITH LONG LEGS OUT.
TYPICAL BEAM SIZEDOUBLE ANGLE MINIMUM
THICKNESSQUANTITY OF
BOLTS
L4x3 DOUBLE ANGLE CONNECTION,TRIM LEG AS REQUIRED, TYP FOR 6",
7", & 8" HSS COLUMNS. PROVIDEL4X4 FOR 10" HSS COLUMNS
FIELD WELDED SHOP BOLTED
L4x3 DOUBLE ANGLECONNECTION
3/4"Ø A325-N BOLTS,SEE TABLE BELOWFOR QUANTITY
BEAM, SEE PLAN
4"
1/2"
1 1/
2"3"
3"1
1/2"
1 1/
2"
3"3"
1 1/
2"TYP3"
FILLET WELDSIZE (W)
3/4"Ø A325-NBOLTS, SEE TABLE BELOW
FOR QUANTITY 1 1/2"
WTYP
W 2WTYP RETURN
CAPACITY(KIPS)
1 1/
2"
TYP.4"
HSS COLUMN,SEE PLAN
L4x3 DOUBLE ANGLECONNECTION, TRIM LEG AS
REQUIRED, TYP FOR 6", 7", &8" HSS COLUMNS. PROVIDE
L4X4 FOR 10" HSS COLUMNS
HSS COLUMN,SEE PLAN
HSS COLUMN,SEE PLAN
BEAM, SEE PLAN
W10,W12 35/16 1/4 48
W16 4
W18 5
W21 6
W24, W27 7
5/16"
5/16"
5/16"
3/8"
1/4
1/4
1/4
5/16
80
115
150
223
W14 35/16" 1/4 48
ALL BOLTED DOUBLEANGLE CONNECTION SCHEDULE
L4x3-1/2 DOUBLE ANGLECONNECTION, SEE TABLE
BELOW FOR THICKNESS
FIELD BOLTED SHOP BOLTED
L4x3-1/2 DOUBLE ANGLECONNECTION. SEE TABLEBELOW FOR THICKNESS
3/4"Ø A325-NBOLTS. SEE TABLEBELOW FOR QUANTITY
BEAM, SEE PLAN
NOTES:1. CONNECTIONS MAY BE FIELD BOLTED OR SHOP BOLTED TO BEAM WEB AT
SUPPLIER'S OPTION.2. ALL DOUBLE ANGLE CONNECTIONS MUST COMPLY WITH OSHA REGULATIONS.3. DOUBLE ANGLE CONNECTION OPPOSITE SIDE OF BEAM WEB SHALL HAVE
SHORTENED ANGLE AND ONE LESS BOLT. OPPOSITE SIDE WEBS.
TYPICAL BEAM SIZEDOUBLE ANGLE MINIMUM
THICKNESSQUANTITY OF 3/4"Ø
A325-N BOLTS
4"
1/2"
1 1/
2"3"
3"1
1/2"
1 1/2"
TYP1 1/2"
1 1/
2"
3"3"
1 1/
2"
3/4"Ø A325-NBOLTS. SEE TABLE
BELOW FOR QUANTITY
W10, W12 31/4"
W16 4
W18 5
W21 6
W24, W27 7
5/16"
5/16"
5/16"
3/8"
W14 35/16"
CONSULTING GROUP,INC.
901 W. Garden St. Pensacola, FL 32502P: 850-438-0050 F: 850-432-8631
SEE PLAN TYPENOTE:EMBEDDED PLATE IS TYPICALLY CENTERED ON BEAM. OFFSET EMBEDDED PLATE AS REQUIRED WHERE EDGE OF CONCRETE IS CLOSER TO CENTER OF BEAM THAN 1/2 PLATE WIDTH.
"h" "W"T.O.S. W16 4 12" 5/16" 1/4" A
[ W21 6 18" 5/16" 1/4 B= :ixt= : NOTE: SEE DETAIL 10/S-505 FOR
EMBED PU\TE SCHEDULE?•!ON 1" RETURN,
I/ TYP."W"
Vv VL6x4x"t" EACH
SIDE OF WEB
EMBED PLATE PER SCHEDULE
BEAM, SEE PLAN= =
#3 TIES @8" O.C.
V S505 /BEAM TO CONCRETE CAP BEAM DETAIL
V S505JBEAM TO CONCRETE CAP BEAM SCHEDULE
3/4" = r-0" 3/4" = 1'-0"
1 2 3 4 5
1/2" COL COLTYP'. 3/161/2" CAP PLATE 1/2"
LARGER THAN COLUMN
1/2"-3 SIDES
W/BEAM, SEE PLAN 3/16BEAM, SEE PLAN SCHMIDTCOL
tIt MAX# OF 3/4"0 A325 BOLTS
BEAM, SEE PLANCONSULTING-GROUP,INC.SEE PLAN 1BEAM, SEE PLAN7 MECHANICAL ELECTRICAL STRUCTURAL
COMMU NICATIONS INDUSTRIALo 0 T.O.S. tactl o _4" SEE PLAN
P: 893-4380093 F: 8934 32-863T02
Ttyp.\pI 0
3/8" PLATE > EACH SIDE WEB-----
$ O? <> fo Ô1 T.O.S. <> STUART SMITH P.E. FLORIDA LICENSE NUMBER 49738
O4" <>0 I o _ 4j^.TYP, I 0
o0 SC G PROJECT: 2015-176
o f0 0WIDTH OF PLATE IS
WIDTH OF BEAM + 1/2"SEE TYPICAL DETAIL FOR INFORMATION NOT SHOWN
3/4" CAP PLATE W/ (4)-3/4"0 A325 BOLTS
1/4 (2)-L4x4x3/8"EACH SIDE, SHOP BOLTED TO BEAM, TYP EACH SIDE OF WEB
COPE AS REQUIRED
11/2" 11/2"COPE AS REQUIRED SEE TYPICAL DETAIL
FOR INFORMATION NOT SHOWN
HSS COLUMN, SEE PLANHSS COL,
SEE PLAN TRIM LEG AS REQUIRED FOR
WELD HSS COL, SEE PLAN
BEAM TO TUBE CONNECTION DETAIL
BEAM TO TUBE CONNECTION DETAIL
V S505J V S505J V S505JTYPICAL ROOF BEAM OVER COLUMN DETAIL
V S505JTYP BEAM SPLICE DETAIL
3/4" = r-0" 3/4" = r-0" 3/4" = r-0" 3/4" = r-0"
8" FILL W/5000 PSI GROUT AFTER BEAM INSTALLATION
POCKET
~t>t~ PACK VOID w/GROUT AFTER BEAM INSTALLATIONBEAM, SEE PLAN"D" MARK "D" "W"4" 4" 3/8" PLATE W/
1 - 5/8"0 X6" HEADED STUDS
:•
BEAM BEARING PLATE, SEE PLAN AND SCHEDULE FOR SIZE AND LOCATIONS
BP 1 6" 15" 1/2"1 SEE PLAN------ PACK VOID W/ GROUTAFTER BEAM INSTALLATION
1/4 4 1/4 4FULL WIDTH
OF PLATE.1/4 /‘ y BP 2 6" 9" 1/2"1/4 4 1/4 4TYP’.•T 1/4
BP 3 6" 8" 1/2" <>FILL W/FIRE GROUT 1/2" PLATE W/
2 - 5/8"0X6" HEADED STUDS
' o 8"X16" BOND BEAM X 4‘-0" LONG W/ (2)-#5 CONT. T&B + #3 TIES
2 #5 TOP & BOTTOM,STANDARD 90° HOOKENDS, #3 TIES @ 6"
1/4 4
1/4 4
2' - 8"
1' -
4"
4 FILLED CELLSMIN, SEE PLAN
FILL W/ 5000 PSIGROUT AFTER BEAMINSTALLATION
PACK VOID W/ GROUTAFTER BEAM INSTALLATION
PACK VOID W/ GROUTAFTER BEAMINSTALLATION
3/8" PLATE W/1 - 5/8"Ø X6"HEADED STUDS
FILL W/ FIRE GROUT
4 FILLED CELLS @BEAM BEARING
BOND BEAM W/ 2 - #6CONT. MIN 4'-0" EACHSIDE
POCKET
8"
4" 4"
PROVIDE 1" CLEARMINIMUM, ALL SIDES.
COPE ASREQUIRED
HSS COL,SEE PLAN
1/2" CAP PLATE1/2"LARGER THANCOLUMN
COL.
SEE TYPICAL DETAILFOR INFORMATIONNOT SHOWN
BEAM, SEE PLAN
TYP.4"
1/4
TYP.1/2"
COPE ASREQUIRED
HSS COL,SEE PLAN
SEE TYPICAL DETAILFOR INFORMATIONNOT SHOWN
BEAM, SEE PLAN
TYP.4"
COL
T.O.S.SEE PLAN
TRIM LEG ASREQUIRED FOR
WELD
3/8" PLATEEACH SIDE WEB
HSS COLUMN,SEE PLAN
WIDTH OF PLATE ISWIDTH OF BEAM + 1/2"
1 1/2" 1 1/2"
3/4" CAP PLATE W/(4)-3/4"Ø A325 BOLTS
COL
T.O.S.SEE PLAN
3/16
3/163 SIDES
BEAM, SEE PLAN
L6x4x"t" EACHSIDE OF WEB BEAM, SEE PLAN
MAX # 3/4"Ø A325N BOLTS IN LONGSLOTTED HOLES, PROVIDE PLATEWASHERS OVER SLOTS
3/4"ØX6" HEADED STUDS, SEETYPE FOR LAYOUT
EMBED PLATE PERSCHEDULE
SEE BEAM TO CONCRETE WALLSCHEDULE FOR BEAM CONNECTIONINFORMATION NOT SHOWN,DETAIL 9/S-505
"h"
"W"1" RETURN,TYP.
T.O.S.SEE PLAN
6"
NOTE:EMBEDDED PLATE IS TYPICALLYCENTERED ON BEAM. OFFSET EMBEDDEDPLATE AS REQUIRED WHERE EDGE OFCONCRETE IS CLOSER TO CENTER OFBEAM THAN 1/2 PLATE WIDTH.2'