Top Banner
WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20 Development Team
22

WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

Jan 01, 2016

Download

Documents

Merilyn Miles
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 1

WinTR-20 Project Formulation Hydrology

Converting Old TR-20 Input Files

to New WinTR-20 Format

Presented by:

WinTR-20 Development Team

Page 2: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 2

WinTR-20 Data Converter

The data converter subprogram is within the new WinTR-20 editor.

Converts most items in the old TR-20 input data set (Version dated 1983 and later).

The data can be run in the present WinTR-20 format.

Page 3: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 3

WinTR-20 Data Converter(continued)

Some features in the old TR-20 program are not used in the new WinTR-20 and will not translate.

These features will be ignored during the conversion:- Runoff Option in Rainfall Distribution Table

- IPEAKS (intermediate peak output) - Multiple time increments (new WinTR-20 will take care of this automatically).

Page 4: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 4

WinTR-20 Converter Output Option Considerations

The output options used in the Old TR-20 input files translate over to the new version.

The user could revise the output parameters in the new data file:- Global Output- Sub-Area or Reach record

Page 5: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015

5

WinTR-20 Converter Reach Routing Considerations

Reach routing has been revised in the new program, the user will have to input additional data.

The routine in the new WinTR-20 (Muskingum-Cunge) requires:- Elevation- Discharge- End Area- Top Width- E.G. Slope

tables for ALL reach routing

Page 6: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 6

WinTR-20 Converter Reach Routing Considerations

(continued)

There is no provision for parametric routing (i.e. the “X” and “m” option with the old TR-20 ATT-KIN method) in the new version.

Any reach section using “X” and “m” in the Old data must have a complete cross section rating table developed (Elevation, Discharge, End Area, Top Width, and E.G. Slope).

Page 7: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 7

WinTR-20 ConverterReach Routing Considerations

(continued)If Old TR-20 data set had “XSECTN”

tables:–Converter program will calculate the top

width from the old TR-20 “XSECTN” table data.

–User only has to add the energy grade (E.G.) slope to the rating table.

Page 8: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 8

ExampleConverting Old TR-20 Data File

to New WinTR-20 Format

Page 9: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 9

WinTR-20 Converter Example

Double click on WinTR-20 icon.

WinTR-20 System Controller / Editor Window will pop up.

Click on “Convert old Data” from the “File” pull down menu.

Page 10: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 10

WinTR-20 Converter Example (continued)

Select Old TR-20 data file to convert (Example: A1.dat)

Page 11: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015

WinTR-20 Converter Example (Continued)

After Old TR-20 data file selected and converted – WinTR-20 Identifier window will appear.

You may make changes to:- Min. Hydrograph Values:- Watershed Description:

Click “Accept Changes” if changes were made, otherwise click “No Changes (Close)” to close this window.

11

Page 12: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 12

WinTR-20 Converter Example (continued)

WinTR-20 System Controller / Editor Window will appear.

Select “Stream Cross Section:” to add the missing “E.G. Slope”.

Page 13: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 13

WinTR-20 Converter Example (continued)

Select “Stream Cross Section - Xsec 1” from pull down menu.

Cross Section data will appear.

“Top Width” values – calculated automatically from old TR-20 data.

Page 14: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 14

WinTR-20 Converter Example (continued)

To enter the missing “E.G. Slope”:– Click on the line

from the table;– Data appears;– Enter “E.G. Slope”;

Click on “Display Data” button to view Cross Section plot.

Click on “Accept Changes (Close)” button to close this window.

Page 15: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 15

WinTR-20 Converter Example (continued)

Peak Output and Hydrograph Output for “Sub-Area” and “Reach” – click on “Global Output:”.

“Global Output” Window will appear.

At least one item on this window needs to be selected (either Yes or any number entered).

Page 16: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 16

WinTR-20 Converter Example (continued)

The User can enter or leave blank as default – Hydrograph Print Precision:– Minimum Hydrograph

Display Flow:– Print Time Increment:

For Peak Output and Hydrograph Output for “Sub-Area” and “Reach” – check “Yes”

Click on “Accept Changes (Close)” button to close this window.

Page 17: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 17

WinTR-20 Converter Example (continued)

Save new WinTR-20 data – select “Save As” from the “File” drop down menu.

Give a new file name with “.inp” extension.

Click “Save” to continue.

Page 18: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 18

WinTR-20 Converter Example (continued)

To view the schematic - select “Schematic” from the “View” drop down menu.

If the schematic looks OKAY! – exit the schematic window (If Diverts were used check them closely).

Page 19: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 19

WinTR-20 Converter Example (continued)

To view the Input File - select “Input File” from the “View” drop down menu.

Click “Close” button to exit this window.

Page 20: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 20

WinTR-20 Converter Example (continued)

To perform the calculation – select “Run” from the main menu.

After a successful run – the WinTR-20 Printed Page File will appear.

You are Done!

Page 21: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 21

The End

Page 22: WinTR-20 Data Converter May 2015 1 WinTR-20 Project Formulation Hydrology Converting Old TR-20 Input Files to New WinTR-20 Format Presented by: WinTR-20.

WinTR-20 Data Converter May 2015 22