Window/Door Replacement - Residential Permit Guidelines (size for size) CGC, CBC, CRC, Specialty aluminum Structural, Specialty Carpentry, Specialty Finish Carpentry or Owner/Builder may apply for permit • Miscellaneous application. • Two (2) copies of floor plan/site or elevation plan showing location (locate windows by number) – See attached sample • Two (2) copies of window/door specifications and Florida Product Approval (make, model and series; installation instructions – latest edition; description of proposed impact protection – shutters) • Two (2) copies of the U-factor/Solar Heat Gain Co-efficient (Required only if the value of the replacement work, materials & labor, exceeds 30% of the assessed value. If it does not exceed 30% the assessed value the U-factor/Solar Heat Gain Co-efficient is no longer required. This is to be determined during the review process not the counter) • Two (2) copies of Window/Door/Shutter worksheet • Owner/Builder Affidavit (if homeowner). • NOC if value is $2500 or greater. Description: • Number of windows/doors being replaced Route to: OFFICE USE ONLY Building (POD) Processing: OFFICE USE ONLY • Type: Window/Door Replace • Subtype: Residential Inspections: 10 • Notice of Commencement (NOC) 20 • Miscellaneous Final (070) Fees: • Window/Door Replacement $113.00 • Surcharge YES Expiration: • Six (6) months NOTE: Replacement windows and new windows installed in sleeping rooms are required to comply with the Florida Building Code for Emergency Escape and Rescue Openings for size; minimum clear height, minimum clear width and minimum opening area. For replacement windows the Florida Building Code Existing allows a maximum of 5% reduction in the clear opening dimensions of replacement doors and windows. Locations of bedrooms or sleeping rooms shall be noted on the floor plan. 3/11/2019 Page 222 of 235
21
Embed
Window/Door Replacement - Residential Permit … Door Replacement...Window/Door Replacement - Residential Permit Guidelines (window to door / door to window) CGC, CBC, CRC or Owner/Builder
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Window/Door Replacement - Residential Permit Guidelines (size for size)
• Two (2) copies of floor plan/site or elevation plan showing location (locate windows by
number) – See attached sample
• Two (2) copies of window/door specifications and Florida Product Approval (make, model
and series; installation instructions – latest edition; description of proposed impact
protection – shutters)
• Two (2) copies of the U-factor/Solar Heat Gain Co-efficient (Required only if the value of the replacement work, materials & labor, exceeds 30% of the assessed value. If it does not exceed 30% the assessed value the U-factor/Solar Heat Gain Co-efficient is no longer required. This is to be determined during the review process not the counter)
• Two (2) copies of Window/Door/Shutter worksheet • Owner/Builder Affidavit (if homeowner). • NOC if value is $2500 or greater.
Description:
• Number of windows/doors being replaced
Route to: OFFICE USE ONLY
Building (POD)
Processing: OFFICE USE ONLY
• Type: Window/Door Replace
• Subtype: Residential
Inspections: 10
• Notice of Commencement (NOC) 20 • Miscellaneous Final (070)
Fees:
• Window/Door Replacement $113.00
• Surcharge YES
Expiration:
• Six (6) months
NOTE: Replacement windows and new windows installed in sleeping rooms are required to comply with the Florida Building Code for Emergency Escape and Rescue Openings for size; minimum clear height, minimum clear width and minimum opening area. For replacement windows the Florida Building Code Existing allows a maximum of 5% reduction in the clear opening dimensions of replacement doors and windows. Locations of bedrooms or sleeping rooms shall be noted on the floor plan.
3/11/2019 Page 222 of 235
~ ~ vJ 5(::,\-.::) ~ l L..J==1
t--1, E:,R: ~n" DIN l:)f'.-_
, v.11"~ ~n-\ · L B/\Tbt
1· cN1lc) LIV bf?"
t I
' &AR. D \A! vJ
I I _._
'i w
l ct '7 {p
'
~AnFLE FLA}J
SAMPLE OF FLOOR PLAN SHOWING WINDOW/DOOR LOCATIONS
NOTE: Per Building Official, if more than 25% of the windows and/or doors in the home are being replaced and the windows/doors are NOT impact glass, the windows/doors are required to have shutters (3-20-09).
For product approvals for window and door, use the following websites:
CGC, CBC, CRC or Owner/Builder may apply for permit
• Miscellaneous application.
• Two (2) copies of floor plan/site or elevation plan showing location (locate windows by
number) – See attached sample
• Two (2) copies of window/door specifications and Florida Product Approval (make, model
and series; installation instructions – latest edition; description of proposed impact
protection – shutters)
• Two (2) copies of the U-factor/Solar Heat Gain Co-efficient (Required only if the value of the replacement work, materials & labor, exceeds 30% of the assessed value. If it does not exceed 30% the assessed value the U-factor/Solar Heat Gain Co-efficient is no longer required. This is to be determined during the review process not the counter)
• Two (2) copies of Window/Door/Shutter worksheet
• Engineering ONLY IF the opening for the door is LARGER(wider) than the existing
window size. NO Engineering is required if the door is the same size (in width) as the
existing window being replaced and if all they are doing is opening the wall right
NOTE: If any additional work is being done in addition to the openings, then all of the
work would be covered under a remodel permit.
*Architectural/Engineered sealed plans required.
CGC, CBC, CRC or Owner/Builder may apply for permit
• Miscellaneous application.
• Two (2) copies of floor plan/site or elevation plan showing location (locate windows by
number) - See attached sample
• Two (2) copies of window/door specifications and Florida Product Approval (make, model
and series; installation instructions – latest edition; description of proposed impact
protection – shutters)
• Two (2) copies of the U-factor/Solar Heat Gain Co-efficient (Required only if the value of the replacement work, materials & labor, exceeds 30% of the assessed value. If it does not exceed 30% the assessed value the U-factor/Solar Heat Gain Co-efficient is no longer required. This is to be determined during the review process not the counter)
• Two (2) copies of Window/Door/Shutter worksheet
• Two (2) copies of signed/sealed engineered plans.
• Owner/Builder Affidavit (if homeowner).
• NOC if value is $2500 or greater.
Description:
• Adding new opening for window/door
Route to: OFFICE USE ONLY
Building (POD)
Processing: OFFICE USE ONLY
• Type: Window/Door Opening
• Subtype: Residential
Inspections:
• Notice of Commencement (NOC)
• Tie Beam (006)
• Frame Rough (007)
• Miscellaneous Final (070)
Fees:
• Window/Door Replacement
• Surcharge
• Structural Miscellaneous
Expiration : • Six (6) Months
3/11/2019
10
20
30
40
$113.00
YES
$100.00
Page 228 of 235
2J L/ v-J w $::,\".:) :JJ
l I t==s· I'
t--1, ~ -· ., , I -~ )I
5-✓
, w . -'\ ;;, ~n~ . L
51-\Tbt , ~
J
i -t,~) L IV ~}2 r
~-.:
{ l
• t &AR. D \A}
'W -~- __ , __ I \J../ ,---.
. i <l '/ {p
,,
I _I
'5AMFLE. FLAJ--J
·'
SAMPLE OF FLOOR PLAN SHOWING WINDOW/DOOR LOCATIONS
NOTE: Replacement windows and new windows installed in sleeping rooms are required to comply with
the Florida Building Code for Emergency Escape and Rescue Openings for size; minimum clear height,
minimum clear width and minimum opening area. For replacement windows the Florida Building Code
Existing allows a maximum of 5% reduction in the clear opening dimensions of replacement doors and
windows. Locations of bedrooms or sleeping rooms shall be noted on the floor plan.
Last Rev.
Page 229 of 235
Florida Building Code Online Page 1 of 4
BCIS Home [ Log In I User Registration Hot Topics I Submit Surcharge I Stats & Facts
~ Product Approval ~ USER: Publlc User
Product Approval Menu > Product or Application Search > APPiication list > Application Detail
FL#
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date Validated By
7630.1 a. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Single Door - lnswing or "ClassicCraft" and "ClassicCraft Outswing configuration (X) Rustic"
Limits of Use Insta llation I nstructions Approved for use in HVHZ: No FL.7!iJQ R!i II INST 7630.1.Qdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 I mpact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.1 for Design Pressure Ratings, any F!.7!iJQ R!i AE EVAL 72J0. l.11df
additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClasslc and SmoothStar doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of installation.)
-7630.2 j b. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Single Door with sidelite -
"ClassicCralt" and "ClassicCraft I nswing or Outswing configuration (OX or XO) Rustic"
,,
Limits of Use Insta llation Instructions Approved for use in HVHZ: No FL72JQ R!i II Inst 7630.2.Qdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Eva luation Reports Other: See INST 7630.2 for Design Pressure Ratings, any F1.7!iJQ R!i AE EVAL 72JQ.i.11df
additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites, this product approval requires the use of "J" part numbers for these doors and sidelites, which have been stained or painted within six months of installation.)
7630.3 c. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Single Door with sidel ites -"ClassicCralt" and "ClassicCraft Inswing or Outswing configuration (OXO) Rustic"
Limits of Use Installation Instructions Approved for use in HVHZ: No FLZ!iJQ R!i II Inst 7!iJQ,J.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.3 for Design Pressure Ratings, any FL7!i3Q R!i AE EVAL 7§J0.J.11df
additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites, this product approval requires the use of "J" part numbers for these doors and sidelites, which have been stained or painted within six months of installation.)
7630.4 d. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Double Door - Inswing or "ClassicCraft" and "ClassicCraft Outswing configuration (XX) Rustic"
Limits of Use Installation Instructions Approved for use in HVHZ: No F!.72JQ R!i II INST 76JQ.4.11gf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.4 for Design Pressure Ratings, any FL7!iJQ R!i AE EVAL 7!iJQ.4.Qdf
additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or pa inted within six months of installation .)
7630.5 e. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Double Door with sidelites -"ClassicCraft" and "ClassicCraft lnswing or Outswing configuration (OXXO) Rustic"
Limits of Use Installation Instructions Approved for use in HVHZ: No FLZ!iJQ R!i II Inst 7!iJQ.S.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
02355-00001 02355-00001 02355-00001 ArborwatchTM x
~ Homeward™ xx ;;,,; VillaaerTu
~ Arcadia"' XX~Ashurst™
Bella™ ncial™
X X
THERMA TRU® THERMA TRU DOORS
l l 8 INDUSTRIAL DR., EDGERTDN, O H 4351 7
iMOOTH STAR", "FIBER CLASSIC", SIC CRAFT" & "CLASSIC CRAFT RUSTIC" LAZED FIBERGLASS SINGLE DOOR w/ SIDELITE
INSWING I OUTSWING 5: (.'.)"IMPACr' :cill
5:
< u, ~
u:J z~ ~ <
c:i >< "(
Jc/ hos been evoluoled and is in compfionce with the 5th Edition (2014) Florido Building ><"( <
CJ structural requirements excluding the 'High Velocity Hurricane Zone" (HVHZ). < ~ 6 ~ C, a;mchors shall be as fisted and spaced as shown on details. Anchor embedmenf to base 0-
;hall be beyond wall dressing orstucco.
id in areas requiring wind bome debris protection this product complies with Section ,( the FBC and does not require on impact resistant covering. This product meets missile nd includes Wind Zone 4 as defined i.1 ASTM E 1996 and Section 1609.1.2.2 of the FBC.
d framing construction, anchoring of these units shall be the same as that shown for 2x onry construction.
ilions that deviate from the defoils of this drawing require further engineering analysis by a
har locations al the comers may be adjusted lo maintain /he min.
hor /acalions noledas 'MAX. ON CENTER" mus/ be adjusted lo nin. edge dis/once to mortarjoints, addifionol concrete anchors ed la ensure /he 'MAX. ON CENTER" dimension ore not exceeded. hortable:
ANCHOR SIZE
MIN. EMBEDMENT
MIN. CLEARANCE TO MASONRY
EDGE
MIN. CLEARANCE TO ADJACENT
ANCHOR
1/4" 1-1/4" 2" 4"
1/4" 1-1/ 4" 1· 4"
rINSTALJ.AUONNOTES: ..,;,_.,_ ~10" ,,..,,./,...,.. ,,./;,., ,..,..,..,.. I " ,,..,..,1,-1;,.1,..,..,..,.. II I",.. ,..
l
STRIKE JAMB
'CHOR NOTES:
1 to mortarjoints.
!:?
SEE HINGE DETNL
HINGE JAMB
,!;!g "'>-.., CD
u ~
" 0.. 0 V)-~ zeo 0
iii ~~~ ~ ~e~ a::
frl~l!!lE 1§ 1§ 0 "- Q.0:,:,
"'"'"'--- L,,J
" gi - ,_- <
co - ..,o
"'"' -~ "'"' 5 20 08
= N.T.S. DWG. B'I': AL QO(. B'I': LFS D.~WL~ NO.:
,;.: 0. ;z
~ 2 0 u 0 z ii., ; 0HINGE DETAIL j ri
,,,..,..,..;,..,.. ,..( ..
..:....
_;.
7 MASONRY OPENING
FRAME_/
2X BUCK
----,-..:,_
--~-~ 1=-r 6-~lb I I I I I I !o
7~ TYP. HEAD &
JAMBS
•~[
ufl :!: ci
J __j_
SILL SILL -r•,-r~ I I I 11
.:•'\
FRAME ANCHORING Mosofll)'2X buck conslruclion
LATCH & DEADBOLT DETAIL
t
t ~ g
f I i ! I I i !.: ~
! ! i,i
&
TTEM DESCRIPTION A IX BUCK SG >.a 0.55 B 2X Allr-r tr.: >.a n H
C MAX. I /4" SHIM SPACE D I 14" X 2-314" PFH ELCO OR rrw CONCREJE SCREW
MASONRY - 3,000 PSI MIN. CONCREJE CONFORMING TO ACI E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 F I /4" X 1-314" PFH rrw CONCREJ'E SCREW H I /4" x 3-114" PFH rrw CONCREJI: SCREW I I /4" X 2-1 /4" PFH rrw CONCREJ'E SCREW J I /4" X 3-3/4" PFH rrw CONCRETE SCREW K #BX 2-J /2" PFH WOOD SCREW L # 10 X 2-1 /2" PFH WOOD SCREW M #9 X 2• I /2" PFH SCREW N IX MUWON REINFORCEMENT (SG >= 0.42/ I EXTERIOR LITE FRAME 2 INTERIOR LITE FRAME 3 LITE FRAME TRIM 4 #J0X l-lf2"PFHSCREW 7 MEDIUM REACH COMPRESSION WEATHERSTRIP 8 LONG REACH COMPRESSION WEATHERSTRIP 9 4" X 4" HINGE .09r THK. JO #IO X 314" PFH WOOD SCREW /HINGE TO FRAMEI 12 # 10 X 2" PFH WOOD SCREW 17 PASSAGE LOCK - KWIKSET SIGNATURE SERIES 18 THRESHOLD OUTSWING 19 HEADER JAMB I PINE) SG >= 0.42 20 SJDE JAMB IPINEI SG >= 0.42 21 DEADBOLT - l<WIKSET SJGNAJURE SERIES (780) 22 INSWING SIDELITE ADAPTERS 23 OUT'SWING SIDELITE SPACER 24 S/UCONE CAULK 27 LATCH STRIKE Pl.ATE 28 DEADBOLT Pl.ATE 32 DOOR BOTTOM SWEEP 33 INSWING THRESHOLD ITI-IERMA-TRUJ 34 INSWJNG THRESHOLD CS ADJUSTABLE 35 INSWJNG THRESHOLD ADJUSTABLE 36 INSWING THRESHOLD ADJUSTABLE 37 INSWING THRESHOLD SELF ADJUSTABLE 38 INSWING THRESHOLD IMPERIAL
NOTE: WOOD DOOR COMPONENTS: PINE OR OAK (SG >= 0.42)
SILL OF MAJHJAI.S MATER/AL TTEM DESCRIPTION WOOD 40 FIBERGLASS uuOR PANEL. SMOOTH STAR Wf">f">D 41 FIBERGLASS SMC SKIN MIN 0.065" THICKNESS WOOD 42 IUl'RAIL
S'TEEL 43 LATl..M SIJLE 44 HINGE STILE
CONCREJ'E 45 i,uTTOMRA/l
S'TEEL 46 POLYUREJHANE FOAM CORE - I. 9 LBS. DENSITY
STEEL 50 FIBERGLASS DOOR PANEL - FIBER CLASSIC STEEL 51 FIBERGLASS SMC SKIN MIN 0.06S' THlCK.Nfil
STEEL 52 TOP RAIL STEEL 53 lA/LH~/11.1;
STEEL 54 HINGEmLE STEEL 55 BOTTOM RAIL
WOOD .56 l'ULYUREJHANE FOAM CORE - I. 9 LBS. DENSITY
ALUMINUM 60 FIBERGLASS DOOR PANEL - CLASSIC CRAFT & CLASSIC CRAFT RUSIJC ALUMINUM 61 t-ltltKGLASS ™C SKIN MIN 0.IMI' THICKNl-55
PVC 62 TOP RAIL STEEL 63 LATCH STILE FOAM 64 HINGE STILE FOAM 65 BOTTOM RAIL STEEL 66 1 ,-uLYu1<1:1nANE FOAM CORE - I. 9 LBS. DEN'S/TY
Business & Professional Regulation BCIS Home Log I n User Registration Hot Topics Submit Surcharoe Stats & Facts Publications FBC Staff BCIS Site Map Unks Search
dP~r ~ Product Approval ~ USER: Public User ·1'\~tAL Pr9ll11Cl t,pprov~I Menu > Product or AppUcation Search > AQPUCfltlOD l lSt > Applic.ition Detail \J \~DD\J FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/ Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/ Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard )
Equivalence of Product Standards Certified By
Fl1435-Rl9
Revision
2014
Approved
S-J'GM\11~L *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
https://floridabui lding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsbCUITKel20DuttT ... I 0/4/20 17
a Building Code Online
1435.6 SH-5500
its of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/ A Other: Please see the Installation I nstructions for design
pressure, size and anchorage informat ion.
FL1435 R19 AE SH-5400 Evaluation.pdf Created by Independent Third Party : No
WinGuard Vinyl Single Hung Window
Certification Agency Certificate Fl 1435 R19 C CAC SH-5500 Certification.pdf
Quality Assurance Contract Expiration Date 10/01/2018
Installation Instructions FL1435 R19 II SH- 5500.pdf Verified By: A. Lynn Miller, P.E. 58705 Created by Independent Third Party: No Evaluation Reports FL1435 R19 AE SH-5500 Evaluat ion.pelf Created by Independent Third Party: No
~ :: 2601 B1i11cstone Road Tallahassee Ft 32399 Phone· 850-487-1824
Page 3 of 3
The state of Florlda Is an AA/EEO employer. Coovciaht 2007-2013 State of flocida : : Privacy Statemc:nt :: Access1b11jty Statement : : Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released in response to a publlc-rec.ords request, do not send electronlc mall to this entity. I nstead, contact the offlce by phone or by trad itional mall. If you have any questions, please contact 850.487.1395. •Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, llcensees Hcensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record . If you do not wish to
supply a personal address, please provide the Department with an email address which can be made avallable to the pubUc. To determine lf you are a licensee under Chapter 455, F.S., please cl!ck ~ -
Product Appr oval Accepts:
~~~~El
Credit Card Safe
securityMnR1cs·
https://fl oridabu i ldi ng.org/pr/pr_ app _ dtl .aspx?param=wGEVX QwtDqsbCUITKel20DuttT ... I 0/4/20 17
DECADES r~oon:cnou . •~Tl::tfNGtH
www.pgtindustries.com
Line# Item Description
0001 MUL Tl-PART MULTI-PART UNITS
Sales Order#
PO Number:
Job Name:
Job Address:
Quantity
\J l LL :J\--\OU ~NER-0 '{ 1=f:~<f0~1\N,c.E, A~D Dlz.St01'.\ f12£ ':h L.) RE/J
1076463
KNIGHT
NONE
Location
FRONT DEN (1 .00) 36.X98.5X.,5500,SGLS,MTCH COL,W, .625FLANGE
Ordered: 2.00
PO Number:
0001 (2.00)
0001 (3.00)
BEGIN MODEL SET 001: ::::::::::::: Combination Configuration: SGLS Unit 2: PW5520 Frame Type: .625FLANGE Send Mull(s): Y Size Slection: ACTUAL Height: 98.5000 Frame Color: White Boxing Options: N
Certification Type: AAMAA440 Vent Configuration: EQUAL Size Selection: CUSTOM Height: 74 3/4 Rough Masonry: 37 3/4 X 75 3/4 Egress: 31 3/4 X 28 15/16 (6.387 SQFT) Does unit need to meet Turtle Code: NO
Ordered: 2.00
Series: 5500.0000 Unit 1 (Bottom Left Unit): SH5500 Continuous Shape Multi-Part: N Assembly Options: MTCHCOL Mull Part Selection: MULUCVR/CLPS Width: 36.0000 Horizontal Mull: 1.25X3.25X.100 Glass Color: CL
FRONT DEN
Frame Type: .625FLANGE Window Style: STD Size Ref: ACTUAL Actual Size: 36 X 74 3/4 Wood Frame: 36 1/4 X 75 Frame Color: White
Glass: 7/8" LIG (1/8 AN - 7/16 ARG -5/16 AN/AN Argon Gas: ARGON
GENERAL NOTES: SERIES 5500 IMPACT RESISTANT, VINYL SINGLE HUNG WINDOW --
1) THIS PRODUCT HAS BEEN DESIGNED 8 TESTED TO COMPLY WITH THE REQUIREMENTS OF me FLORIDA BUILDING CODE.
2)ALL WOOD BUCKS LESS THAN 1-1/2" THICKARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUSSTRATE W OOD BUCKS D EPICTED AS 2X ARE 1-1/2' THICK OR GREATER. 1X ANO 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN ANO INSTALLATION IS THE RESPONSIBILITY OF TIIE ENGINEER, (EOR) OR ARCHITECT OF RECORD, (AOR).
3) ANCHOR EMBEOMENT TO BASE MATERIAL SHALL OE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENTEMBEDMENT. INSTALLATION ANCHORS SHOULD OE SEALED. OVERALL SEALING/FLASHING SlRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE OONE BY OTHERS AND IS BEYOND THE SCOPE OF 1 HESE INSTRUCTIONS.
4) MAX. 1/4" SHI\ IS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE TI,E PRODUCT IS NOT FLUSH TO TI-iE SUBSTRATE. USE SHIMS CAPABLE rn::: TRANSFERRING APPI.IEO LOADS. WOOD BUC<S. BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE l',SNOOW.
5) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINOLOAOS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3',', STRESS INCREASE HAS NOT BEcN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THATCOME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE.
'RM\1
M/\X. BUCK WIDTH _ SEE TABLE 1
28" MAX DUCK WIDTH 1 SEE TABLE 1 =-1
M fvl. . 1t . r-I ~1- r--1 [
2" M _ D,SEE " Mfvl.. 0.C.~ r--- 4
SHEET 4 ------~ C,SEE12'Ml'v'..
SHEET 4_j_
17.867" MAX. O.C.
I.. <"MAX.
SEEo.c. M/\X. BUCK E 1 HEIGHT SEE
r I
L
I Q
~
--
·1 /I I
I
,7-2" Ml'v'..
-
r I
I
I
-
I M/\X. B UCK HEIGHT
TABL
~10" M/\X. Of.
ELEVATION FOR TYP. FLANGE FRAME, PROVIEW/ORIEL CONFIGURATION
(COTTAGE SIMILAR)
TABLE 1·
Window Buck Size
Width
52-1/6"
52-1/8"
52-1/8"
52-1/8"
52-1/6"
52-1/8"
uCERT. OF AUTH. #29206
1070 TECHNOLOGY DRIVE ··-- -· - ·---
Height
64"
84"
91-13/16"
64"
84"
91-13/16"
Configuration
Equal-lite
Std. PraView
Custom Sash
Equal-lite
Std. PraView
Custom Sash
5 VINYL SH WINDOW FPA (IMP.-RESIST.) & 12/13/14
~ GENERAL NOTES & ELEVATIONS ~£
, ,:, ... .;,
-.i~ ... .J;g
Reinf. Level
R1
R2
TABLE 1
D
ELEVATION FOR TYP. FIN OR J-CHANNEL FRAME. EQUAL-UTE CONFIGURATION
(SIMILAR ANCHOR DIMENSIONS FOR OTHER CONFIGURATIONS)
Design Pressure
(+) psf
50.0
65.0
(·) psf
50.0
70.0
Certification (CAR) Number
190-285, 1028
190-286, 1029
SHAPES MAY BE USED BY INSCRIBING THE SHAPE IN A BLOCK ANO OBTAINING DESIGN PRESSURES FOR THAT BLOCK SIZE FROM THE TABLE ON THIS SHEET.
WINDOW SHAPES AS SHOWN BELOW OR SIMILAR, MAY OE USED BY INSCRIBING THE SHAPE IN A BLOCK ANO OBTAINING DESIGN PRESSURES ANO ANCHORAGE FOR TtiAT BLOCK SIZE FROM THE TABLE ON SHEET 1.
1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 (941 )-480-1600
~
INSTALLATION NOTES:
1) SEE SHEET 1 FOR SPACING REQUIREMENTS. 2) SEE TABLE(S) ON SHEET 2 FOR ANCHORAGE ANO SUBSTRATE REQUIREMENTS. 3) MAX. SHIM THICKNESS TO BE 1/4'. 4) GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN REQUIREMENTS. 5) FIN ANO/OR FLANGE MAY BE REMOVED TO CREATE OTHER FRAME TYPES