DNV serving the energy industry

Page 2: Wind, wave and tidal energy DNV serving the energy industry.

Type Testing Definitions

Mechanical Loads Measurement, generally per IEC 61400-13

This test is characterized by application of numerous strain gages, accelerometers, displacement and position sensors on a machine for purposes to measure loads in the machine structure. It requires installation of a hub height meteorological mast; the data system typically runs for at least 6 months as a remote installation.

Power Performance Measurement, generally per IEC 61400-12

This test is characterized by measurement of a suite of wind inflow conditions along with approximately ten turbine operation channels, including net power production. It requires installation of a hub height meteorological mast; the data system typically runs for at least several months as a remote installation.

Power Quality Measurement, generally per IEC 61400-21

This test is characterized by very high resolution measurement and analysis of electrical output waveforms to quantify machine attributes such as flicker and total harmonic distortion in a variety of conditions. It is generally continuously attended by engineers and/or technicians for a duration measured in days or weeks.

Acoustic Noise Measurement, generally per IEC 61400-11

This test is characterized by sound recording using a screen-shielded microphone in a standard position and orientation, mounted on a standard platform. Wind speed and direction measurements are referenced to 10 meter height, and often a short meteorological mast of this height is used. It is generally continuously attended by engineers and/or technicians for a duration measured in days or weeks.

Page 3: Wind, wave and tidal energy DNV serving the energy industry.

Type Testing Applications

Mechanical Loads Measurement, generally per IEC 61400-13

This test is most often applied to new turbine designs for purposes of certification. It is also used frequently to evaluate internal developments (new blades, new controls, etc.) and validate simulation models. Wind turbine manufacturers are the primary market, but the service could also be of use to others (evaluating loads effects of retrofits, etc.). This service is not often used to verify loads performance of machines because calculated design loads generally are neither site-specific nor published to owners.

Power Performance Measurement, generally per IEC 61400-12

This test is most often applied by wind turbine owners to verify power performance of their installations. It is also regularly applied by manufacturers to verify power performance of new design types before publishing a warranted power curve or similar documentation.

Power Quality Measurement, generally per IEC 61400-21

This test is often applied by manufacturers to ensure grid (network) code compliance of new design types. It may also be applied by owners at the turbine or park level, to address concerns with interconnection.

Acoustic Noise Measurement, generally per IEC 61400-11

This test is applied to both new designs (manufacturers verifying type performance) and operating machines (owners and/or local parties verifying noise levels).

Page 4: Wind, wave and tidal energy DNV serving the energy industry.

Relative Test Activity in Parts

Categorized in terms of Time (Duration) and Data Density (Sampling Rate).

Loads (61400-13)

- Largest overall data volume (20-200 Hz)

- Extensions of the standard are common

- Most complex calibrations

Power Performance (61400-12)

- Subset of loads data

- Considers only 10-minute averages

Power Quality (61400-21)

- Separate data system

- High sampling rates, shorter duration

Acoustic Noise (61400-11)

- Separate data system

- High sampling rates, shorter duration

Time

Data Density

LoadsPPT

Power Quality

Acoustic Noise

Page 5: Wind, wave and tidal energy DNV serving the energy industry.

Typical Loads Layout

Our systems are designed for multiple machines, though in

practice one test turbine is most common.

Page 6: Wind, wave and tidal energy DNV serving the energy industry.

Standard Loads Deliverables

Test PlanThe test plan includes reference to standards that will be followed, turbine descriptions, a full

channel list, desired capture matrix, data delivery and other reporting schedules. We always issue a test plan with our loads measurement services, but the scope and length of the test plan varies according to client preferences and requirements.

Instrumentation ReportThe instrumentation report provides details of the installation, for purposes of records and/or

troubleshooting.

Calibrated Data FilesOur preferred and internal working format is MATLAB, but we can deliver measured data in a

variety of formats, to customer specifications. Deliveries occur regularly throughout the test campaign, with frequency determined by customer needs.

Progress/Status ReportsWe often deliver updated capture matrices with statistics plots and summaries of channel validity

in order to allow tracking of progress and identification of especially interesting wind conditions or events. The progress/status reports also include a log of test activities and events.

Final ReportWe offer final reports according to the IEC 61400-13 standard, or other standards and

specifications required by clients.

Page 7: Wind, wave and tidal energy DNV serving the energy industry.

IMC Measurement System

De Facto Industry Standard

CAN Bus System for Remote Stations

Combo Box Configurability

Fast Analysis and Monitoring of Signals (FAMOS) Software & Native File Formats

Page 8: Wind, wave and tidal energy DNV serving the energy industry.

IMC Loads Test Layout

CAN

CAN over F.O.

CAN over F.O.

Signal Bundle

Ethernet

FTP Data

Windows PC

Page 9: Wind, wave and tidal energy DNV serving the energy industry.

Results Using IMC Option

Industry Standard Setup

Rapid Raw Data Delivery

Responsive Service & Reporting

Page 10: Wind, wave and tidal energy DNV serving the energy industry.

Bachmann M1 PLC

Full PLC Logical Capability

Flexible Bus Systems

Real time Quality Checking Capability

Digital Output Event Triggering Capability; Safe Remote Triggering of Special Events

System Notifications via Email, Status Logs

MATLAB Data Storage Format, Other Translations Possible

Commonly Known in the Industry

Reliability to Run 10,000+ Safety Critical Wind Turbine Controls

Page 11: Wind, wave and tidal energy DNV serving the energy industry.

Bachmann M1 Loads Test Layout

CAN

Rotor Data Backup

FAST Bus (F.O.)

Ethernet SMI

Signal Bundle

Ethernet

FTP Data

PC Optional

Online Quality Checks

Page 12: Wind, wave and tidal energy DNV serving the energy industry.

Results Using Bachmann M1 Option

Industry Leading Setup

Improved Reliability

Improved System Flexibility

Triggering, Secondary Sets

Online Quality Checks

Email Notifications

Rapid QC’d Data Delivery

Responsive Service & Reporting

Page 13: Wind, wave and tidal energy DNV serving the energy industry.

Committed to leadership

DNV – helping the industry safely turn the renewable energy potential into sustainable business value