Page 1
Wind & solar Hybrid ControllerOperating Instruction Manual
BeforeBeforeBeforeBefore use,pleaseuse,pleaseuse,pleaseuse,please readreadreadread thisthisthisthis mmmmanualanualanualanual
ThanksThanksThanksThanks forforforfor selectingselectingselectingselecting ourourourour companycompanycompanycompany provideprovideprovideprovide thethethethe windwindwindwind andandandand PVPVPVPV hybridhybridhybridhybrid powerpowerpowerpower systemsystemsystemsystem controllercontrollercontrollercontroller seriesseriesseriesseries
WWWWishishishish totototo bringbringbringbring youyouyouyou thethethethe bestbestbestbest productproductproductproduct andandandand satisfactorysatisfactorysatisfactorysatisfactory serviceserviceserviceservice!
Page 2
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
1
I.I.I.I. ProductProductProductProduct IntroductionIntroductionIntroductionIntroduction
DWSC602 family type is the most notable feature of wind and solar controller with LCD Chinese and
English menu interface, convenient for customers to easily complete a variety of control parameters and system
status of the visit, the unique remote communications capabilities, allowing customers to stay at home to keep
abreast of the work system and control; in addition, as the battery overvoltage protection, under voltage
protection, reverse polarity protection, short circuit protection, charge and discharge over-current protection, fan
over-speed protection, automatic braking and other basic protection more effective protection system safe and
reliable operation; two DC output, multiple operating modes: normally open, normally closed, light-controlled
open + control + light control when closed. LED lights on the load for the user, we also increased the power
output of your adjustable function, free energy-saving program settings.
Model Description:
D W S C 602 - 24 - P
LCD display
Rated battery voltage
Rated power controller
Controller
Solar
Wind Energy
Manufacturers
ProductionProductionProductionProduction featurefeaturefeaturefeature
♠ Exclusive use of three-phase soft brake technology within the industry, protect wind turbine more perfectly.
♠ Menu-driven operation,no manual,can directly manipulate,simple and easy to understand.
♠ Over-speed protection of the wind turbine,the turbine can effectively self-protection in windy conditions,to
extend the life of the entire system.
♠ Temperature display,real-time monitoring controller operating environment.
♠ Integration of multiple voltage,current,power meter,real-time monitoring of various parts of the electrical
parameters.
♠ Warranty 2 years,better service for end customers and integrators.
Page 3
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
2
♠ The majority parameters of the system can be setted by user,designed with flexibility better adapt to different
systems.
APPLICATIONAPPLICATIONAPPLICATIONAPPLICATIONAREAS:AREAS:AREAS:AREAS:
♠ Stand alone wind/solar hybrid power station.
♠ Stand alone domestic household wind/solar hybrid power system.
♠ GSM base stations, expressway and other no-residential regions.
♠ Coastal islands, remote mountainous, border posts for regions shortage of or without electricity.
♠ Government demonstration projects, landscape lighting project, street light project etc.
WARMWARMWARMWARMPROMPTS:PROMPTS:PROMPTS:PROMPTS:
Customers, who will order the wind/solar hybrid street light controllers, need to provide the following
information
♠ Rated battery voltage
♠ Rated DC load power
♠ Rated solar power
♠ Rated wind turbine power
♠ Whether the wind turbine is three phase AC output, single phase DC output or single phase AC output.
2.2.2.2.MainMainMainMain technicaltechnicaltechnicaltechnical parametersparametersparametersparameters
Model DWSC302-12 DWSC602-24
Rated Voltage 12V 24V
Battery maximum current 30A 30A
Rated Power of Solar panels 150W 300W
Voltage of Power on 1V(adjust able) 2V(adjust able)
Voltage of Power off 2V(adjust able) 4V(adjust able)
Rated Power of Wind Power 300W 600W
Maximum Speed of Wind turbines 100~2000r /min(adjust able)
Series of Wind turbines 6~35级(adjust able)
Page 4
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
3
Time of brake renewing of Wind turbines 10min ~60min (adjust able)
Float charging voltage 14V (adjust able) 28V (adjust able)
Charge return voltage 12.5V (adjust able) 25V (adjust able)
Over-discharge protection voltage 10V (adjustable) 20V (adjust able)
Over-discharge recovery voltage 11V (adjustable) 22V (adjust able)
Compensation factor of Charging temperature
(optional)
2mV/℃/2V(adjust able)
-20~65℃
4mV/℃/2V (adjust able)
-20~65℃
Maximum current 10A (could be designed)
Load Output(two independent outputs ) Normally closed 、normally open、light-control、
time-control、light&time-control
Load output Current 10A
Load output period 1~15hour(adjustable)
Load output power(optional) 0~100%(LED dedication)
Ambient temperature -20~+55℃
Storage temperature -30~+65℃
Operating humidity range 35~85%RH(no condensation)
Elevation Altitude ≤5500 M
Case size 127mm*150mm*75mm
Case material Milky/Black paint
Protection function Solar reverse charge&connection protection, Battery over
charge、 over discharge 、 reverse connection protection,
Lightning protection ,Wind turbine over speed 、current
limiting、automatic brake and manual brake
IIIIIIIIIIII、WiringWiringWiringWiring DiagramDiagramDiagramDiagram
Page 5
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
4
Wiring Figure 3-1
Attention!Attention!Attention!Attention!
Batteries and solar panels can not be reversed polarity , Wind power, regardless of the order of three lines
, DC output + Cathode lamps connected ,-1(Timed output)、-2(For the light control output)Respectively, then
the negative two-way street .
NotesNotesNotesNotes::::
1、Remove the controller, the controller is no visual damage to transport .
2、Select the corresponding operating voltage of the battery, the machine with the battery polarity protection
Although, it is still forbidden battery positive and negative reversed.
3、Battery connected and working correctly, connect the DC output,than wind turbine and solar panel.
4、Finally, access to wind turbines and solar panels, can not take no.
IVIVIVIV,,,, LCDLCDLCDLCD displaydisplaydisplaydisplay
Figure 4-1
Figure 4-1 shows the main interface for the control
Page 6
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
5
Display meaning of the following specific:
1. for the 12V system, for the 24V system .
2. that dawn , that dark .
3. rotating said wind energy in the rotating state, still, said wind energy in the stationary state,
Said fan brake .
4. 1 working status indicator lights: that an output means for normally open or normally closed mode, this
mode is that light has been lit; 1 output mode that is too controlling (H) mode, this mode is that light has
been lit , that an output mode for the light control (L) mode, This mode is that light has been lit .
5. 2 working status indicator lights, and four said the same meaning .
6. Battery charge indicator: Flashing indicates the battery voltage is about , That serious battery
feed , Said battery saturated and blinking battery overvoltage . Said 40% battery power, That the
battery power of 60%, and so on .
7. Net that the battery charge current, unit A (ampere)
8. Ambient temperature, temperature compensation reference.
9. Wind turbine speed display unit r / min.
110.Battery voltage, the unit V (V)
VVVV、SETUP PARAMETERS
Figure 5-1
For DATA key input The key is in the menu Settings/sure modification parameter; The ESC menu or cancel
Page 7
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
6
the revised; exit Menu up /add / Menu/down to move down
FIG. 5-2
FIG. 5-2 for the key operate flow chart, need attention points:
1.In the key is from level 2 menu into the parameters set .If parameters for frame shows
,Upper left is for ,It says the parameters can be modified ,That is
left for the says the parameters cannot be modified. Any parameters set after the completion of the must be
preserved .if upper left Disappear, said changes success,Press Esc exit is modified
failure.
1. When the parameters after setting, must press the Esc key returned to the interface, front set after all
parameters can take effect, it was sure to remember.
ManualManualManualManual brakebrakebrakebrake:
Automatic control in addition to brake function outside, still have a manual brake function,按住 hold the
Esc + fan braking,Esc+ remove fan brake.
VIVIVIVI、FunctionFunctionFunctionFunction CodeCodeCodeCode TableTableTableTable
System operating parameters:
Parameter entry Parameters Explain Function,Range Modify
Page 8
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
7
1 battery cell voltage Now the battery voltage ××××
2 Solar voltage Solar panels at present voltage ××××
3 Fan voltage The wind generator voltage value at
present
××××
4 Solar current Solar panels output current ××××
5 Fan current Wind turbine output current ××××
6 Total charge current Battery charging electric current ××××
7 Output 1 current 1 loaded output current ××××
8 Output 2 current 2 loaded output current ××××
9 Fan speed Wind power at present speed ××××
10 Ambient temperature Work environment temperature system ××××
11 solar panel board power Solar panels to power output ××××
12 Exhauster wattage The wind generator power output ××××
13 Output 1 power Load 1 power ××××
14 Output 2 power Load 2 power ××××
15 Output 1 time 1 already work time. Load ××××
16 Output 2 time 2 already work load time ××××
SystemSystemSystemSystem setsetsetset parametersparametersparametersparameters:
Parameters Parameter specification Function, scope statement the factory
value
Modificat
ion
1 System working voltage System work rated voltage 12/24V ××××
2 Storage battery charging
pressure
Storage battery charging pressure 14X2 √√√√
3 Restore charge voltage Battery below this threshold start
charging after
12.5VX2 √√√√
4 Allows the discharge
voltage
Ready to discharge, the battery voltage
is lower than this value can not load
discharge.
11VX2 √√√√
Page 9
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
8
5 Battery over-discharge
voltage
Battery voltage below this value to
stop the load discharge.
10VX2 √√√√
6 Maximum charge
current
Battery allows the charge current is
larger than this value of the
automatical system which will
reduce the battery charge.
30A √√√√
7
Light control voltage
lights
Solar panel will output voltage falls
below this value which will began to
load and discharge.
1V×2 √√√√
8 Light control of voltage
lights
Solar panel will output voltage which
is larger than this value of the load
discharge.
2V×2 √√√√
9 Maximum fan speed Wind turbine speed is greater than this
value, the fan automatically braking.
800Rp/m √√√√
10 Automatic braking time Automatic fan delay on the time after
the braking
10min √√√√
11 Generator pole pairs This parameter is read the instructions
or advice blower test blower
manufacturer, set the fan speed
measurement error will cause an error.
6 √√√√
12 Set the power time 2 outputs at work this time into the set
point output power mode.
6H √√√√
13 Set the power factor 12 percent power setting options 100% √√√√
14 1 output mode 0 often close,1 often open,2 Light
control + time control,3 Light control
2 √√√√
15
2 output mode
0 often close,1 often open,2 Light
control + time control,3 Light control
3 √√√√
16 Setting time 1 1 channel output load time. 1 Road 12H √√√√
Page 10
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
9
Work in timed mode, this parameter is
valid.
17 Setting time 2 2-way load output time. 2-way
working at control mode, this
parameter is valid.
12H √√√√
Note:Note:Note:Note:
1. Modify items that can change this parameter, × that can not be modified, √ that can be modified.
2 .Please do not change parameters if customers do not know too much. Because if set the system inaccurate
may affect the charging efficiency, before you buy this, you’d better give the specific parameters or requirements
of functionality to manufacturers, have factory settings, or call us.
VII.Troubleshooting
Phenomenon Check the following order Causes and treatment
Stall fan
1.Check whether the battery is
full the controller
2.Check the brake controller,
manual fan switch
3.Check whether the brake
controller
4.Check the blower output line
between three-terminal
resistance.
1.If full, then the battery is full
2. If the brake, it will switch to running
3. If the brake, then the fan does not turn
4.If one or more sets of resistance in Europe is less
than 0.4, indicating that the fan cable short-circuit, the
corresponding repair
Can not be
charged
1. Check all cables and terminal
access
2. The long-term no wind, no
sun
3. Check the controller input
terminal voltage of solar
4. Check the wind controller
1.If the cable is bad there is need to overhaul
2.If so, is a normal
3.If the voltage is too low, the cable is damaged or
solar panels is damaged, repair or replace accordingly
4. If the voltage is too low, or three sets of voltage is
not equal, indicating the fan motor windings or faulty
fan output cable, and make the appropriate repair
Page 11
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
10
AC voltage between input
terminals
Not lighting
1. Check the battery voltage
indicator controller
2. Check the output mode
3.Check the controller input
terminal voltage of solar
4.Check controller output load
terminal voltage
1.If the voltage indicator lit, it indicates the battery
power is low, or battery aging
2.Determine whether the setting is normally closed
3. If the voltage (higher than 5V), check whether
there is light source around the solar panels, resulting
in miscarriage of justice to dawn controller
4.If voltage, check the lights and connections; if have
not voltages, indicating that the controller failure,
repair
The light
will go on in
daytime
1. 1. Check the solar panels is
keep out
2. Check the controller solar
input terminal voltage3. Check output model
4. Check is normal
1. If there is keep out, then remove keep out content
2. If the voltage is too low (less than 3.8 V),
indicating that cable damage or solar damage,
corresponding repair or replacement
3. To decide whether it is set to often open
Return to factory maintenance
VIIIVIIIVIIIVIII.... AccessoriesAccessoriesAccessoriesAccessories
1. the scenery complementary controller one 2. a manual 3.a certification, 4. the power cord two (the
black and red root)□ 5. and RS232 turn USB2.0 converter□ 6.a random CD□ 7 a packing a set□
8.a screwdriver □ (off with the within said, a cross or blank said the no)
Page 12
HighHighHighHigh performanceperformanceperformanceperformance wind&solarwind&solarwind&solarwind&solar hybridhybridhybridhybrid controllercontrollercontrollercontroller
11
IX.IX.IX.IX.maintemaintemaintemaintenancenancenancenance cardcardcardcard
maintemaintemaintemaintenancenancenancenance cardcardcardcard
◆ this brand power supply before they leave the factory to ensure good quality, through the strict inspection,
has the company to users to ensure that the machine performance is good, complete parts.
◆ this brand series products sold since the date of execution, all a year warranty, to remove the or serious
violations (not according to the instructions) and the failure of the warranty, not within the scope of the company,
but in designated outlets maintenance cost charge.
◆this product warranty period, are more than at cost warranty.
The products are sold out vouchers as a single, please keep.
TheTheTheThe useruseruseruser datdatdatdataaaa sheetsheetsheetsheetDistribution unit: Use the unit:
Buying machine time: contact:
Equipment Numbers: Contact phone number:
The product model: Postal code:
MaintenanceMaintenanceMaintenanceMaintenance recordsrecordsrecordsrecordsdate Maintenance kinds note Maintenance
men
User name