Top Banner

of 45

Whoer Hydr Car Park.pdf

Jul 06, 2018

Download

Documents

Heri Setyanto
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 8/17/2019 Whoer Hydr Car Park.pdf

    1/451

       P   a   r   k   l   i   f   t   3   4   0

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   3   0   4   0

    We compact parking space

    Fon +49 [0] 7044 46-0Fax +49 [0] 7044 46-149

    [email protected]

    P. O. Box 115171288 Friolzheim/Germany

    Otto Wöhr GmbHAuto-Parksysteme

    Data Sheet WöhrParklift 340Single unit = 2 cars Suitable for condominium and office buildings.Double unit = 4 cars For permanent use only!*

    Notes

    1. Car width max. 190 cm (see width details page 2). In case of special platform widths narrower than 230 and 460 cm respectively, the maximum vehiclewidth is reduced accordingly. For cars with two outside mirrors, a minimum platform width of 250 cm or 500 cm is recommended.

    2. For standard lowered cars or cars with front spoilers exceeding the above clearance profiles, we recommend to use our system Parklift 440.

    3. Due to recent increases in car length dimensions, and potential future developments, a pit length of 540 cm is advisable. This offers bigger

    safety distances also for future cars.4. At the edge of the pit a 10cm wide, yellow-black marking according to ISO 3864 has to be provided by the purchaser(see “statics and construction requirements“ on page 3).

    5. The manufacturer reserves the right to modify or alter above specifications.

    Parklift 340-155/150 (height 295) Parklift 340-155/150 (height 305)

    Clearance profile (standard saloon/estate car) Examples (09.2008)

    Upper level saloon carsup to 150 cm

    Lower level saloon/estate cars 158up to 154 cm

    car height distance (h)Upper level saloon cars

    up to 160 cmLower level saloon/estate cars 158

    up to 154 cm

    car height distance (h)

    The various model-series versions may vary in

    size and/or dimensionally, based on versionconfiguration, design and execution!

    Cars up to 150 cm/154 cm height:e.g. Audi Variant; BMW-Touring; Opel-Caravan;VW-Variant, always without roof rails

    Cars up to 160 cm height:e.g. MB A-class; VW Golf V, New Beetle; Smart

    * The total car height includes roof rail and antenna fixture and must not exceed thementioned max. height dimension.

    X = to be clarified with  door supplier

    15

    sl ope 7 ,5° =13% 

    460

    Dimensions in cm

    155+3

    0

    400

    100

    Both platforms are inclined.

    Load per platform max. 2000 kg(load per wheel max. 500 kg)

    70

    min.300 cm horizontalmax. slope 1%

    X

    150+30

    min.18

    15

    85

    60

    free space for door20

    60

    slope 5 °= 9 %

    h

    w   a  l   l    o   p  e  n  i   n   g    f    o  r   

    e  l   e  c  t   r   i   c  a  l    a  n  d   

    h   y   d   r   a  u  l   i   c   s  e  r   v   i   c  e  s  

    X = only applicaple if garage  doors are to be fitted.  For roller doors x = 10/15 cm

    clear heightfor a lintel

      p  o  s  s   i   b   l  e

       c   h  a

      n  n  e   l

       1  0  x  2

       p   l  u

      s

      r  e  c  e

      s  s   f  o  r   s

      u  m  p   p  u

      m  p   5  0

      x  5  0  x  2

      0

      p  o  s  s  i   b   l  e 

      s  p  a  c

      e

      f  o  r   s

      u  c  t  i  o

      n

      530+10

    0

    2%   2%

    50

    155

    295

    150+30+3

    0

    +30

    305

    155 150+3

    0

    +3

    0

    +30

    13

    12060   3814

    275 22

    46

    90max.290500

    48

    81627540

    37

    154*

    10

    22

    38

    2025

    90   55   162

    500120

    275

    60max. 290 90

    46

    65   8

    14

    48150*

    (154*)(160*)

    Please attend to restricted car- and platform distance height! If higher cars or platform distance heights are requested, we suggest to useour Parklift 440 system.

  • 8/17/2019 Whoer Hydr Car Park.pdf

    2/452

       P   a   r   k   l   i   f   t   3   4   0

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   3   0   4   0

    Width dimensions · Underground garages

    Wall to wall

    Pillars outside pit

    Pillars inside pit

    Important notes

    All dimensions shown are minimum. Construction tolerances must be taken into consideration.All dimensions in cm.

    The access to the Parklift should be level for a distance of 300cm immediately in front of the pit (max. slope allowable 1%).Beyond this max. slope 10%.

    If not stated differently in the of fer, platform widths of 230 cm or 460 cm will be delivered. Bigger/smaller platform widths can be deliveredat additional price.

    Cars wider than 190 cm should be parked on platforms270/500 cm width only.For spaces against walls, or at end of rows, werecommend that largest possible platform widths areutilized to assist turning motion.

    If maximum platform widths are not installed, difficulties mightarise when entering or exiting the cars on the parking units.This depends on the car type, the access and the individualdriving behaviour.

    Space requiredB

    gives clearplatform width

    260270280290300

    230240250260270

    Space requiredB

    gives clearplatform width

    490510530

    460480500

    gives clearplatform width

    750780810820830

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Space requiredB

    Wall openings required betweenpartitions for electrical and hydraulicconduits must be provided whereapplicable. Wall openings may notbe closed after installation.

    Single unit (2 cars)

    B

    S

    Double unit (4 cars)

    B

    D

    Combinated unit (6 cars)

    B

    D S

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    250 240

    260 250270 260280 270290 280

    230

    240250260270

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    480 470

    500 490520 510

    460

    480500

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    740 730

    770 760800 790810 800820 810

    460+230

    480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Single unit (2 cars)

    B

    S S

    B1

    min. 20

    Double unit (4 cars)

    B

    D

    B1

    D

    Combinated unit (6 cars)

    B

    D

    B1

    S D Smin. 20 min. 20

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    255 245265 255275 265285 275295 285

    230240250260270

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    485 475505 495525 515

    460480500

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    745 735775 765805 795815 805825 815

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Single unit (2 cars)

    B

    S S

    B1

    min.15

    max.100

    Double unit (4 cars)

    B

    D

    B1

    max.100

    D

    Combinated unit (6 cars)

    B

    D

    B1

    max.100

    S D Smin.15 min.15

  • 8/17/2019 Whoer Hydr Car Park.pdf

    3/45

  • 8/17/2019 Whoer Hydr Car Park.pdf

    4/454

       P   a   r   k   l   i   f   t   3   4   0

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   3   0   4   0

    Electrical datas Installation diagram

    Item Performance Quantity Designation Position Frequency

    3 by customer as locally acc. to local power supply feed cable to 1 perrequired regulations main switch power pack

    3Ph+N+PE*

    1 by customer 1 unit electric meter in the feed cable

    2 by customer 1 unit fuse or automatic circuit in the feed cable 1 perbreaker 3x16A slow blow power packacc. to DIN VDE 0100 p. 430

    4 by customer each foundation earth corner pit floor/10 m connector rear wall

    5 by customer 1 unit equipotential bonding from foundation 1 peracc. to local requirements earth connector Parklift

    to Parklift

    Items 8–14 are included in Wöhr’s scope of delivery unless otherwise specified in theoffer/order.

    6 by customer 1 unit marked main switch, above operating 1 perlockable to prevent device power packunauthorized switching on

    7 by customer 10m PVC control cable with from main switch 1 permarked strands and pro- to hydraulic power power packtective conductor 5 x 1,52 pack

      7 PVC control cable 5x 1.52  from main switch to assembly

      4 Foundation earth connector 5 Equipotential bonding from  foundation earth connector  to Parklift

      9 PVC control cable 5 x1.52

      8 Hydraulic unit with three-phase  motor, 230/400V, 50Hz, 1.5/3.0kW.  Switching cabinet with motor,  protection, wired already for  installation

    11 PVC control cable 5 x1.52

      to the next facility

    10 Branch connector

    12 Operating device for UP/DOWN withEMERGENCY-STOP. If possible on theleft, but always outside the platform’smovement range. Cables always feed infrom below. (2 keys per parking place.)

    13 PVC control cable7 x1.52

    14 Cyl inder valve cable  PVC control cable 3 x1.52

    120 cm 110 cm

    conduit

      3 Feed line to the main switch

      1 Electric meter  2 Fuse or automatic circuit breaker  3 x16A slow blow according to  DIN VDE 0100 part 430

    6 Lockable main switch

    The electrical componentssuppliedbythemanufacturermust be connected in accord-ance with the appropriate wiringdiagram and local regulations.

    German VDE electrical require-ments must be adhered to, inorder to validate the TÜV testedcircuit.

    The electrical supply to thepower pack(s) must be provided

    prior to or during installation toenable our fitters to completetheir work satisfactorily and tocheck the correct functioningof the units.

    Parklifts has to be grounded tothe foundation earth connectorby customer. A foundation earthconnector should be provided bycustomer each 10 m or acc. tolocal requirements.

    * DIN VDE 0100 part 410 + 430 (not under permanent load) 3PH+N+PE(three-phase current) Note: Where a door is used to close the garage, themanufacturer of the door must be consulted before the electric cable is laid.

    Free spaces

    Maintenance

    Railings

    Recesses and conduits for rotaryswitches with rolling and sectional gates

    Protection against corrosion

    Dimensions

    Noise protection

    Temperature

    Drainage

    Conformity test

    Illumination

    BA

    BA

    A

    B

    8 8

    ====

    15

    Plastic or steel armoured conduit M 20

    Flexible plastic insulation pipe M 20

    Above plaster

    115 above access level

    Under plaster

    7

    min.20

    +0,5

    Basis is the German DIN 4109“Noise protection in buildings”.

    With the following conditionsrequired 30 dB (A) in roomscan be provided:

    – noise protection packagefrom our accessory

    – insulation figure of the

    construction of min. R’w = 57dB– walls which are bordering

    the parking systems must bedone as single wall anddeflection resistant with min.m’= 300 kg/m2

    – solid ceiling above theparking systems with min.m’= 400 kg/m2

    At differing constructionalconditions additional soundabsorbing measures arenecessary.

    The best results are reachedby separated sole plates fromthe construction.

    Increased noise protection:

    If increased noise protectionmust be provided planning hasto be confirmed on a projectbasis by Wöhr (further buildingmeasures are required).

    The installation is designed to operate between +5°and +40°C.Atmospheric Humidity: 50% at +40°C. If the local circumstancesdiffer from the above please contact Wöhr.

    We recommend the provisionof a drainage channel at thefront of the pit which can eitherincorporate a pump sump50 x 50 x 20 cm, or a connectioninto the storm water sewerage

    system via a petrol/oil intercep-tor. To prevent any possibilityof contamination of the ground-water we recommend that thepit floor is coated with an oilproof paint.

    All our systems are checked according to EC machinery directive98/37/EG and EN 14010.

    Illumination has to be considered acc. to local requirements by client.

    The units need to be provided acc. EN ISO 13857 with safety railingsif the gap between unit and wall exceeds 20cm. If walkways are arrangeddirectly to the side or behind the systems, railings have to be provided byclient acc. to local requirements, height min. 200 cm – this is applicableduring the construction phase too.

    Special drawings for free spaces to accommodate air ducts or otherpipes can be requested at Wöhr Agent!

    Regular maintenance by qualified personnel can be provided by meansof an Annual Service Contract.

    Independent of a maintenance workings has to be carried out acc. toWöhr Cleaning and Maintenance Instruction regularly.

    Clean up galvanized parts and platforms of dirt and road salt as wellas other pollution (corrosion danger)!

    Pit must be always ventilated and dearated well.

    All dimensions shown are minimum. Construction tolerances mustbe taken into consideration. All dimensions in cm.

    Notes

    In case of standard lowered cars with spoilers, contact CompanyWöhr or local agent.

  • 8/17/2019 Whoer Hydr Car Park.pdf

    5/451

       P   a   r   k   l   i   f   t   4   0   1

      ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   3   0   2

    We compact parking space

    Fon +49 [0] 7044 46-0Fax +49 [0] 7044 46-149

    [email protected]

    P. O. Box 115171288 Friolzheim/Germany

    Otto Wöhr GmbHAuto-Parksysteme

    Data Sheet WöhrParkbox 401dependent parkingFor permanent use only!*

    Notes

    1. According to the examples shown above the required height and length dimensions depend on the car size and parkingdirection (frontwards/reverse).

    2. Max.car width 190 cm, clear platform width 220 cm. Installation width 260 cm (forwards), installation width 280 cm(forwards and reverse parking) .P

    3. According to ISO 3864 the floor has to be marked with 10 cm wide yellow-black stripes at a distance of 90 cm from the platformedge by the purchaser (see “statics and construction requirements“ on page 2).

    4. The manufacturer reserves the right to modify or alter above specifications.

    70500

    155

    290

    min.18

    min. 300 cm horizontalmax. slope 10%

    * In case of short time user(e.g. for office-, hotel-,commercial building) onlypossible on lower platformand only if technicallyadjusted, ask WÖHR!

    Or with attendant or valetparking both levels arepossible for short time user.

    Load per platformmax. 2000 kg(load per wheel 500 kg)

    Dimensions in cm

    +30

    155

    305

    530

    70

    min.18

    +30

    100

    280

    585

    155

    min.18

    +30

    170

    70

    315

    500

    min.18

    +30

    hydraulic power pack

    260(280) 220

    Please attend to restricted car-and platform distance height!

  • 8/17/2019 Whoer Hydr Car Park.pdf

    6/452

       P   a   r   k   l   i   f   t   4   0   1

      ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   3   0   2

    Electrical datas Installation diagram

    Item Performance Quantity Designation Position Frequency

    3 by customer as locally acc. to local power supply feed cable to 1 perrequired regulations main switch power pack

    3Ph+N+PE*

    1 by customer 1 unit electric meter in the feed cable

    2 by customer 1 unit fuse or automatic circuit in the feed cable 1 perbreaker 3x16A slow blow power packacc. to DIN VDE 0100 p. 430

    4 by customer each foundation earth corner pit floor/10 m connector rear wall

    5 by customer 1 unit equipotential bonding from foundation 1 peracc. to local requirements earth connector Parklift

    to Parklift

    Items 8–16 are included in Wöhr’s scope of delivery unless otherwise specified in theoffer/order.

    6 by customer 1 unit marked main switch, above operating 1 perlockable to prevent device power packunauthorized switching on

    7 by customer 10m PVC control cable with from main switch 1 permarked strands and pro- to hydraulic power power packtective conductor 5 x 1,52 pack

    9 PVC control cable 5x 1.52 fromassembly to branch connector13 Operating device for UP/DOWN

    with EMERGENCY-STOP. Ifpossible on the left, but alwaysoutside the platform’s movementrange. Cables always feed infrom below. (2 keys per parking place.)

    12 PVC Steuerleitung5 x1.52 von Abzweig-dose zum Drehtaster

    11 PVC control cable 3 x1.52

    from branch connectorto unlock magnet

    14 Unlock magnet

    10 Branchconnector

    7 PVC control cable 5x 1.52

    from main switch toassembly

    6 Lockable main switch

    3 Feed line to the main switch

    1 Electric2 Fuse or automatic circuit breaker

    3 x16 A slow blow according toDIN VDE 0100 part 430

    8 Hydraulic unit with three-phasemotor, 230/400V, 50 Hz,1.5 kW. Switching cabinetwith motor, protection, wiredalready for installation

    16 PVC control cable 3 x1.52 frombranch connector to valve

    15 Cylinder valve

    4 Foundation earth connector5 Equipotential bonding from

    foundation earth connectorto Parklift

    The electrical componentssuppliedbythemanufacturermust be connected in accord-ance with the appropriate wiringdiagram and local regulations.

    German VDE electrical require-ments must be adhered to, inorder to validate the TÜV testedcircuit.

    The electrical supply to thepower pack(s) must be provided

    prior to or during installation toenable our fitters to completetheir work satisfactorily and tocheck the correct functioningof the units.

    Parklifts has to be grounded tothe foundation earth connectorby customer. A foundation earthconnector should be provided bycustomer each 10m or acc. tolocal requirements.

    * DIN VDE 0100 part 410 + 430 (not under permanent load) 3PH+N+PE(three-phase current) Note: Where a door is used to close the garage, themanufacturer of the door must be consulted before the electric cable is laid.

    Notes

    Maintenance

    Statics and construction requirements

    Railings

    Protection against corrosion

    Dimensions

    Noise protection

    Temperature

    Conformity test

    Basis is the German DIN 4109“Noise protection in buildings”.

    With the following conditionsrequired 30 dB (A) in roomscan be provided:

    – noise protection packagefrom our accessory

    – insulation figure of the

    construction of min. R’w =57dB– walls which are bordering

    the parking systems must bedone as single wall anddeflection resistant with min.m’= 300 kg/m2

    – solid ceiling above theparking systems with min.m’= 400 kg/m2

    At differing constructionalconditions additional soundabsorbing measures arenecessary.

    The best results are reachedby separated sole plates fromthe construction.

    Increased noise protection:

    If increased noise protectionmust be provided planning hasto be confirmed on a projectbasis by Wöhr (further buildingmeasures are required).

    The installation is designed to operate between +5°and +40°C.Atmospheric Humidity: 50% at +40°C. If the local circumstancesdiffer from the above please contact Wöhr.

    All our systems are checked according to EC machinery directive98/37/EG and EN 14010.

    If walkways are arranged directly to the side or behind the systems,railings have to be provided acc. EN ISO 13857 by client acc. to localrequirements, height min. 200cm.

    In case of lower cars with spoilers, sontact Company Wöhr or local agent.

    Regular maintenance by qualified personnel can be provided by meansof an Annual Service Contract.

    Independent of a maintenance workings has to be carried out acc. toWöhr Cleaning and Maintenance Instruction regularly.

    Clean up galvanized parts and platforms of dirt and road salt as wellas other pollution (corrosion danger)!

    Pit must be always ventilated and dearated well.

    The Parkbox will be fixed on the anchor points with heavy dutyanchor bolts to a depth of approx. 10–12cm.

    Slab thickness min. 18cm. Recommended concrete quality C20/25!Special foundations are required with asphalt floors or paving-stones.

    All dimensions shown are minimum. Construction tolerances mustbe taken into consideration. All dimensions in cm.

    5

        3 ,     2    4     °

        =      5 ,     6     %

    238220

    220

    155(170)

    x

    P1 = 12 kN*P2 = 4 kN

    x = 70: small andmiddle sizedcars

    x = 100: big sizedcars e.g.BMW series 7

    90

    Marking according to ISO 3864

    *all static

    loadingsinclude theweight ofthe car

    P1

    P2P1

    P2

    P1 P2

  • 8/17/2019 Whoer Hydr Car Park.pdf

    7/451

       P   a   r   k   l   i   f   t   4   0   2  ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   1   0   0

    Data Sheet WöhrParklift 402Single unit = 2 cars Suitable for condominium and office buildings.Double unit = 4 cars For permanent use only!*

    Standard type 402-185/180 Compact type 402-170/165 Comfort type 402-200/195

    Clearance profile (standard saloon/estate car) Examples (09.2008)

    Notes1. Car width max. 190 cm (see width details page 2). In case of special platform widths narrower than 230 and 460 cm respectively, the maximum vehicle

    width is reduced accordingly. For cars with two outside mirrors, a minimum platform width of 250 cm or 500 cm is recommended.

    2. Due to recent increases in car length dimensions, and potential future developments, a pit length of 540 cm is advisable. This offers biggersafety distances also for future cars.3. At the edge of the pit a 10 cm wide, yellow-black marking according to ISO 3864 has to be provided by the purchaser (see “statics and construction

    requirements“ on page 3).4. The manufacturer reserves the right to modify or alter above specifications.

    Upper level: estate cars up to a height of 150cm

    Clear height of 310cm is sufficient, if just cars upto a height of 150cm (no estate cars) should beparked on the upper platform.

    If sufficient headroom is available (305cm),estate cars up to a height of 150 cm can beparked on the upper platform provided that the»free space for door« (see section) is not utilized.

    Estate cars up to a height of 150 cm can be parkedon the upper platform provided that the »freespace for door« is not utilized.

    Clear height of 325cm is sufficient, if just cars upto a height of 150cm (no estate cars) should beparked on the upper platform.

    If vans up to a height of 180 cm are to be parkedon the upper level a clear height of 365cm aboveentrance level is required.

    Pit length min. 540cm.

    The various model-series versions may vary insize and/or dimensionally, based on versionconfiguration, design and execution!

    Cars up to 150 cm height:e.g. Audi A3 to A6; BMW-Touring; Opel-Caravan; VW-Variant, always without roof rails

    Cars up to 165 cm height:e.g. MB A-class, E-class estate, B-class;Opel Omega, Astra; VW Golf V

    Cars/Vans up to 180 cm height:e.g. Mazda MPV; Opel Sintra, Zafira;Renault Espace; VW Sharan

    * The total car height includes roof rail and antenna fixture and must not exceed thementioned max. height dimension.

    Dimensions in cm

    * In case of short time user– only possible on upper platformand only if technically adjusted,ask WÖHR!Or with attendant or valet parking bothlevels are possible for short time user.

    Special reinforcedunits for higherplatform loadings

    are available.

    for roller shutters:

    s l ope 8°  =  14,1% 

    min. 200 cmslope max.5%

    slopemax.14%

    clear heightfor a lintel

    min.18

    530 – 540*

    1015

    15

    20

    free spacefree space for door

    390

    11525

    60

    20

    90

    min. 300 cm horizontal,or else

    X

    Upper platform is in ahorizontal position to drive on.Lower platform is in aninclined position to drive on.

    Load per platform 2000 kg(load per wheel max. 500 kg)

    = only applicable if garage  doors are to be fitted.  For sectional doors: X = 25 cm  For roller shutters: X = 10/ 15 cm

    X

    = to be clarified with  doors supplier

    X

    free spacefor doors

    25 25

    40X

    min.18

    50

    h

      p  o  s  s   i   b   l  e

       c   h  a

      n  n  e   l

       1  0  x  2

       p   l  u

      s

      r  e  c  e

      s  s   f  o  r   s

      u  m  p   p  u

      m  p   5  0

      x  5  0  x  2

      0  w a l l  o p e n i n

     g   f o r

     e l e c t r i c a l 

     a n d

     h y d r a u l i c  s

     e r v i c e s

      p  o  s  s  i   b   l  e 

      s  p  a  c

      e

      f  o  r   s

      u  c  t  i  o

      n

    2%   2%

    185

    320

    180+30+3

    0

    +30

    165+30+3

    0170

    295+30

    200

    335

    195+3

    0+3

    0

    +30

    10

    22

    38

    2025

    90   55   162

    500120

    275

    60max.290   90

    46

    65   8

    14

    48150*(165*)(180*)

    10

    12060   3814

    275 22

    46

    90max.290500

    48

    81626040

    40150*(165*)(180*)

    *

    We compact parking space

    Fon +49 [0] 7044 46-0Fax +49 [0] 7044 46-149

    [email protected]

    P. O. Box 115171288 Friolzheim/Germany

    Otto Wöhr GmbHAuto-Parksysteme

    Upper level saloon carsup to 165 cm

    Lower level saloon/estate cars 170up to 165 cm

    car height distance (h)Upper level saloon cars

    up to 150 cmLower level saloon/estate cars 155

    up to 150 cm

    car height distance (h)Upper level saloon cars

    up to 165 cmLower level cars/vans up to 180 cm 185

    and max. 2000 kg

    car height distance (h)

    Please attend to restricted car- and platformdistance height!

  • 8/17/2019 Whoer Hydr Car Park.pdf

    8/452

       P   a   r   k   l   i   f   t   4   0   2  ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   1   0   0

    Width dimensions · Underground garages

    Wall to wall

    Pillars outside pit

    Pillars inside pit

    Important notes

    All dimensions shown are minimum. Construction tolerances must be taken into consideration.All dimensions in cm.

    The access to the Parklift should be flat of with an declination of max. 5% for a distance of 200 cm immediately in front of the pit.Beyond this the slope should not exceed 14%.

    If not stated differently in the of fer, platform widths of 230 cm or 460 cm will be delivered. Bigger/smaller platform widths can be deliveredat additional price.

    With platform widths 250, 260 and 270cm special reinforced units with max. platform loading capacity of 2.300kg are available forbig limousines e.g. Mercedes-Benz S-class, BMW 7, Audi A8 etc.

    Cars wider than 190 cm should be parked on platforms270/500 cm width only.For spaces against walls, or at end of rows, we recommendthat largest possible platform widths are utilized to assistturning motion.

    If maximum platform widths are not installed, difficulties mightarise when entering or exiting the cars on the parking units.This depends on the car type, the access and the individualdriving behaviour.

    Space requiredB

    gives clearplatform width

    260270280290300

    230240250260270

    Space requiredB

    gives clearplatform width

    490510530

    460480500

    gives clearplatform width

    750780810820830

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Space requiredB

    Wall openings required betweenpartitions for electrical and hydraulicconduits must be provided whereapplicable. Wall openings may notbe closed after installation.

    Single unit (2 cars)

    B

    S

    Double unit (4 cars)

    B

    D

    Combinated unit (6 cars)

    B

    D S

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    250 240260 250270 260280 270290 280

    230240250260270

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    480 470500 490520 510

    460480500

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    740 730770 760800 790810 800820 810

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Single unit (2 cars)

    B

    S S

    B1

    min. 20

    Double unit (4 cars)

    B

    D

    B1

    D

    Combinated unit (6 cars)

    B

    D

    B1

    S D Smin. 20 min. 20

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    255 245265 255275 265285 275295 285

    230240250260270

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    485 475505 495525 515

    460480500

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    745 735775 765805 795815 805825 815

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Single unit (2 cars)

    B

    S S

    B1

    min.15

    max.100

    Double unit (4 cars)

    B

    D

    B1max.100

    D

    Combinated unit (6 cars)

    B

    D

    B1max.100

    S D Smin.15 min.15

  • 8/17/2019 Whoer Hydr Car Park.pdf

    9/453

       P   a   r   k   l   i   f   t   4   0   2  ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   1   0   0

    Single garages (2 cars) Double garages (4 cars)

    Serial garages with single doors (2 cars) Serial garages with double doors (4 cars)

    Statics and construction requirements

    Width dimensions · Garages with doors

    All dimensions shown are minimum. Construction tolerances must be taken into consideration.All dimensions in cm.

    The access to the Parklift should be flat of with an declination of max. 5% for a distance of 200 cm immediately in front of the pit.Beyond this the slope should not exceed 14%.

    If not stated differently in the of fer, platform widths of 230 cm or 460 cm will be delivered. Bigger/smaller platform widths can be deliveredat additional price.

    With platform widths 250, 260 and 270 cm special reinforced units with max. platform loading capacity of 2.300 kg are available forbig limousines e.g. Mercedes-Benz S-class, BMW 7, Audi A8 etc.

    Hydraulic power pack

    Dimensions are in cm 1 –5 Parklifts 6 – 10 Parklifts

    Length = 100 150

    Height = 140 140

    Depth = 35 35

    The location of the hydraulic power pack is determinedaccording to your plan – space requirements are as follows:

    Single unit

    P1 P2

    P1 P2P3

    P3clearplatform-

    width +15

    P1 P2

    P2P1

    P3

    P3

    Double unit

    clearplatform-width +15

    P1 = +35kN *

    P2 = +10kN– 8kN

    P3 = + 3 kN

    P1 = +50kN

    P2 = +15kN–10kN

    P3 = + 3 kN

    *all static loadingsinclude the weightof the car

    Marking according to ISO 3864

    Bearing loads are transmittedto the pit floor by base plates ofapproximately 140 cm2, fixed byheavy duty anchor bolts to a depthof approximately 10–12cm.

    Base plate thickness min. 18 cm(recommended concrete qualityC20/25). When fixing to water-proof concrete floors chemicalanchors are employed (to beadvised by Wöhr).

    The front wall of the pits must beformed of concrete and mustbe perfectly flat and verticalwithout any protrusions.

    The specified lengths to thesupport points are mean values.Please contact us for exactpositions for any variations onthe standard units.

    230

    P3

    P1 P2+

    320430

    x = for doors. See page 1

    Space requiredB B1

    gives clearplatform width

    260 230270 240280 250290 260300 270

    230240250260270

    Space requiredB B1

    gives clearplatform width

    490 460510 480530 500

    460480500

    Minimum drivewaywidth according tolocal requirements

    Wall openings required betweenpartitions for electrical and hydraulicconduits must be provided whereapplicable. Wall openings may notbe closed after installation.

    B

    B1

    15 15

    D

    B

    B1

    15 15

    S

    X

    B

    B1

    15 30

    D

    B

    D

    B1

    30

    Space requiredB B1

    gives clearplatform width

    260 230270 240280 250290 260300 270

    230240250260270

    Space requiredB B1

    gives clearplatform width

    490 460510 480530 500

    460480500

    Minimum drivewaywidth according tolocal requirements

    B

    B1

    15 30

    S

    30 30

    B B

    B1 B1

    S S

    X

  • 8/17/2019 Whoer Hydr Car Park.pdf

    10/454

       P   a   r   k   l   i   f   t   4   0   2  ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   1   0   0

    Electrical datas Installation diagram

    Item Performance Quantity Designation Position Frequency

    3 by customer as locally acc. to local power supply feed cable to 1 perrequired regulations main switch power pack

    3Ph+N+PE*

    1 by customer 1 unit electric meter in the feed cable

    2 by customer 1 unit fuse or automatic circuit in the feed cable 1 perbreaker 3x16A slow blow power packacc. to DIN VDE 0100 p. 430

    4 by customer each foundation earth corner pit floor/10 m connector rear wall

    5 by customer 1 unit equipotential bonding from foundation 1 peracc. to local requirements earth connector Parklift

    to Parklift

    Items 8–14 are included in Wöhr’s scope of delivery unless otherwise specified in theoffer/order.

    6 by customer 1 unit marked main switch, above operating 1 perlockable to prevent device power packunauthorized switching on

    7 by customer 10m PVC control cable with from main switch 1 permarked strands and pro- to hydraulic power power packtective conductor 5 x 1,52 pack

     6 Lockable main switch

      7 PVC control cable 5 x 1.52  from main switch to assembly  8 Hydraulic unit with three-phase  motor, 230/400V, 50Hz, 1.5/3.0kW.  Switching cabinet with motor,  protection, wired already for  installation

      9 PVC control cable 5x1.52

    10 Branch

    11 PVC control cable 5 x1.52

      to the next facility12 Operating device for UP/DOWN withEMERGENCY-STOP. If possible on theleft, but always outside the platform’smovement range. Cables always feed infrom below. (2 keys per parking place.)

    13 PVC control cable7 x1.52conduit

    14 Cylinder valve cablePVC control cable

    3 x1.52

      3 Feed line to the main switch

      1 Electric  2 Fuse or automatic circuit breaker  3 x16A slow blow according to  DIN VDE 0100 part 430

     4 Foundation earth connector 5 Equipotential bonding from  foundation earth connector  to Parklift

    120 cm 110 cm

    The electrical componentssuppliedbythemanufacturermust be connected in accord-ance with the appropriate wiringdiagram and local regulations.

    German VDE electrical require-ments must be adhered to, inorder to validate the TÜV testedcircuit.

    The electrical supply to thepower pack(s) must be provided

    prior to or during installation toenable our fitters to completetheir work satisfactorily and tocheck the correct functioningof the units.

    Parklifts has to be grounded tothe foundation earth connectorby customer. A foundation earthconnector should be provided bycustomer each 10 m or acc. tolocal requirements.

    * DIN VDE 0100 part 410 + 430 (not under permanent load) 3PH+N+PE(three-phase current) Note: Where a door is used to close the garage, themanufacturer of the door must be consulted before the electric cable is laid.

    Free spaces

    Maintenance

    Railings

    Recesses and conduits for rotaryswitches with rolling and sectional gates

    Protection against corrosion

    Dimensions

    Noise protection

    Temperature

    Drainage

    Conformity test

    Illumination

    BA

    BA

    A

    B

    8 8

    ====

    15

    Plastic or steel armoured conduit M 20

    Flexible plastic insulation pipe M 20

    Above plaster

    115 above access level

    Under plaster

    7

    min.20

    +0,5Basis is the German DIN 4109“Noise protection in buildings”.

    With the following conditionsrequired 30 dB (A) in roomscan be provided:

    – noise protection packagefrom our accessory

    – insulation figure of theconstruction of min. R’w =57dB

    – walls which are borderingthe parking systems must bedone as single wall anddeflection resistant with min.m’= 300 kg/m2

    – solid ceiling above theparking systems with min.m’= 400 kg/m2

    At differing constructionalconditions additional soundabsorbing measures arenecessary.

    The best results are reachedby separated sole plates fromthe construction.

    Increased noise protection:

    If increased noise protectionmust be provided planning hasto be confirmed on a projectbasis by Wöhr (further buildingmeasures are required).

    The installation is designed to operate between +5°and +40°C.Atmospheric Humidity: 50% at +40°C. If the local circumstancesdiffer from the above please contact Wöhr.

    We recommend the provisionof a drainage channel at thefront of the pit which can eitherincorporate a pump sump50 x 50 x 20 cm, or a connectioninto the storm water sewerage

    system via a petrol/oil intercep-tor. To prevent any possibilityof contamination of the ground-water we recommend that thepit floor is coated with an oilproof paint.

    All our systems are checked according to EC machinery directive98/37/EG and EN 14010.

    Illumination has to be considered acc. to local requirements by client.

    The units need to be provided acc. EN ISO 13857 with safety railingsif the gap between unit and wall exceeds 20cm. If walkways are arrangeddirectly to the side or behind the systems, railings have to be provided byclient acc. to local requirements, height min. 200 cm – this is applicableduring the construction phase too.

    Special drawings for free spaces to accommodate air ducts or otherpipes can be requested at Wöhr Agent!

    Regular maintenance by qualified personnel can be provided by meansof an Annual Service Contract.

    Independent of a maintenance workings has to be carried out acc. toWöhr Cleaning and Maintenance Instruction regularly.

    Clean up galvanized parts and platforms of dirt and road salt as wellas other pollution (corrosion danger)!

    Pit must be always ventilated and dearated well.

    All dimensions shown are minimum. Construction tolerances mustbe taken into consideration. All dimensions in cm.

    Notes

    In case of standard lowered cars with spoilers, contact CompanyWöhr or local agent.

  • 8/17/2019 Whoer Hydr Car Park.pdf

    11/451

       P   a   r   k   l   i   f   t   4   0   3

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   4   1   3   0

    Data Sheet WöhrParklift 403Single unit = 3 cars Suitable for condominium and office buildings.Double unit = 6 cars For permanent use only!*

    We compact parking space

    Fon +49 [0] 7044 46-0Fax +49 [0] 7044 46-149

    [email protected]

    P. O. Box 115171288 Friolzheim/Germany

    Otto Wöhr GmbHAuto-Parksysteme

    Standard type 403-345/340

    Clearance profile (standard saloon/estate car) Examples (09.2008)

    Notes1. Car width max. 190 cm (see width details page 2). In case of special platform widths narrower than 230 and 460 cm respectively, the maximum vehicle

    width is reduced accordingly.For cars with two outside mirrors, a minimum platform width of 250 cm or 500 cm is recommended.

    2. Due to recent increases in car length dimensions, and potential future developments, a pit length of 540 cm is advisable. This offers biggersafety distances also for future cars.

    3. At the edge of the pit a 10cm wide, yellow-black marking according to ISO 3864 has to be provided by the purchaser (see “statics and constructionrequirements“ on page 3).

    4. The manufacturer reserves the right to modify or alter above specifications.

    The various model-series versions may vary insize and/or dimensionally, based on versionconfiguration, design and execution!

    Cars up to 150 cm height:e.g. Audi A3 to A6; BMW-Touring; Opel-Caravan; VW-Variant, always without roof rails

    Cars up to 170 cm height:e.g. MB A-class, B-class; Fiat Tempra;VW New Beetle; Smart* The total car height includes roof rail and antenna fixture and must not exceed the mentioned

    max. height dimension.

    Comfort type 403-385/380

    10

    22

    38

    2025

    90   55   162

    500120

    275

    60max.290   90

    46

    65   8

    14

    48

    150*(170*)

    10

    12060   3814

    275 22

    46

    90max.290500

    48

    81626040

    40

    150*(170*)

    460

    345 +30 340+3

    0

    +30 525

    385+3

    0 380+3

    0

    +30

    80

    350100

    20

    10

    15

    530–540

    70

    slopemax.14%

    min. 200 cmslope max.5%

    min. 300 cm horizontal, or else

    s l ope 8° = 14,1% 

    Dimensions in cm

    h

    Upper plattform is in a horizontalposition to drive on, middle andlower plattforms are in an inclinedposition to drive on.

    Covered installation:Load per platform max. 2000 kg(load per wheel max. 500 kg)

    = only applicable if garage doorsare to be fitted

    Roller doors:= 15

    Sectional doors:= 25 (single doors)= 30 (double doors)

    = to be clarified withdoor supplier

    X

    X

    X

    X

    X

    X

    15

    mind. 18

    free space for door

    clear heightfor a lintel

    free space

      p  o  s  s   i   b   l  e

       c   h  a

      n  n  e   l

       1  0  x  2

       p   l  u  s

      r  e  c  e

      s  s   f  o  r   s

      u  m  p   p  u

      m  p   5  0

      x  5  0

      x  2  0

     w a l l  o p

     e n i n g   f o

     r

     e l e c t r i c

     a l  a n d

     h y d r a u

     l i c  s e r v

     i c e s

      p  o  s  s  i   b   l  e 

      s  p  a  c

      e

      f  o  r   s

      u  c  t  i  o

      n

    502%   2%

    car height distance (h)Upper level saloon cars up to 150 cm

    Lower level saloon/estate cars up to 150 cm 155Entrance level saloon/estate cars up to 150 cm 155

    If sufficient headroom is available (475cm), estate cars up to a height of150cm can be parked on the upper platform provided that the“free space for door” is not utilized.

    car height distance (h)Upper level saloon cars up to 170 cm

    Lower level saloon/estate cars up to 170 cm 175Entrance level saloon/estate cars up to 170 cm 175

    Estate cars up to a height of 170cm can be parked on the upper platformprovided that the “free space for door” is not utilized.

    Please attend torestricted car- andplatform distanceheight!

  • 8/17/2019 Whoer Hydr Car Park.pdf

    12/452

       P   a   r   k   l   i   f   t   4   0   3

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   4   1   3   0

    Width dimensions · Underground garages

    Wall to wall

    Pillars outside pit

    Pillars inside pit

    Important notes

    All dimensions shown are minimum. Construction tolerances must be taken into consideration.All dimensions in cm.

    The access to the Parklift should be flat of with an declination of max. 5% for a distance of 200 cm immediately in front of the pit.Beyond this the slope should not exceed 14%.

    If not stated differently in the of fer, platform widths of 230 cm or 460 cm will be delivered. Bigger/smaller platform widths can be deliveredat additional price.

    Cars wider than 190 cm should be parked on platforms270/500 cm width only.For spaces against walls, or at end of rows, werecommend that largest possible platform widths areutilized to assist turning motion.

    If maximum platform widths are not installed, difficulties mightarise when entering or exiting the cars on the parking units.This depends on the car type, the access and the individualdriving behaviour.

    Space requiredB

    gives clearplatform width

    270280290300310

    230240250260270

    Space requiredB

    gives clearplatform width

    500520540

    460480500

    gives clearplatform width

    765795825835845

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Space requiredB

    Wall openings required betweenpartitions for electrical and hydraulicconduits must be provided whereapplicable. Wall openings may not

    be closed after installation.

    Single unit (3 cars)

    B

    S

    Double unit (6 cars)

    B

    D

    Combinated unit (9 cars)

    B

    D S

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    260 245

    270 255280 265290 275300 285

    230

    240250260270

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    490 475

    510 495530 515

    460

    480500

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    750 740

    780 770810 800820 810830 820

    460+230

    480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Single unit (3 cars)

    B

    S S

    B1

    min. 20

    Double unit (6 cars)

    B

    D

    B1

    min. 20D

    Combinated unit (9 cars)

    B

    D

    B1

    min. 20S D S

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    260 245270 255280 265290 275300 285

    230240250260270

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    490 475510 495530 515

    460480500

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    750 740780 770810 800820 810830 820

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Single unit (3 cars)

    B

    S S

    B1

    min. 20

    max.140

    Double unit (6 cars)

    B

    D

    B1

    min. 20

    max.140

    D

    Combinated unit (9 cars)

    B

    D

    B1

    min. 20

    max.140

    S D S

  • 8/17/2019 Whoer Hydr Car Park.pdf

    13/45

  • 8/17/2019 Whoer Hydr Car Park.pdf

    14/454

       P   a   r   k   l   i   f   t   4   0   3

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   4   1   3   0

    Electrical datas Installation diagram

    Item Performance Quantity Designation Position Frequency

    3 by customer as locally acc. to local power supply feed cable to 1 perrequired regulations main switch power pack

    3Ph+N+PE*

    1 by customer 1 unit electric meter in the feed cable

    2 by customer 1 unit fuse or automatic circuit in the feed cable 1 perbreaker 3 x 25 A slow blow power packacc. to DIN VDE 0100 p. 430

    4 by customer each foundation earth corner pit floor/10 m connector rear wall

    5 by customer 1 unit equipotential bonding from foundation 1 peracc. to local requirements earth connector Parklift

    to Parklift

    Items 8–14 are included in Wöhr’s scope of delivery unless otherwise specified in theoffer/order.

    6 by customer 1 unit marked main switch, above operating 1 perlockable to prevent device power packunauthorized switching on

    7 by customer 10m PVC control cable with from main switch 1 permarked strands and pro- to hydraulic power power packtective conductor 5x 2,52 pack

     4 Foundation earth connector 5 Equipotential bonding from  foundation earth connector  to Parklift

      3 Feed line to the main switch

      1 Electric meter  2 Fuse or automatic circuit breaker 3 x 25A slow blow  according to DIN VDE 0100 part 430

      6 Lockable main switch  7 PVC control cable 5 x 2,52  from main switch to assembly

      8 Hydraulic unit with three-phase  motor, 230/400 V, 50Hz, 5.5 kW.  Switching cabinet with motor,  protection, wired already for  installation

      9 PVC control cable 5 x1.52

    10 Branch connector

    14 Cylinder valve cablePVC control cable 3 x1.52

    11 PVC control cable 5x1.52

      to the next facility12 Operating device for UP/DOWN withEMERGENCY-STOP. If possible on theleft, but always outside the platform’smovement range. Cables always feed infrom below. (2 keys per parking place.)

    13 PVC controlcable 7 x1.52

    conduit

    120 cm 110 cm

    conduit

    The electrical componentssuppliedbythemanufacturermust be connected in accord-ance with the appropriate wiringdiagram and local regulations.German VDE electrical require-ments must be adhered to, inorder to validate the TÜV testedcircuit.

    The electrical supply to thepower pack(s) must be provided

    prior to or during installation toenable our fitters to completetheir work satisfactorily and tocheck the correct functioningof the units.

    Parklifts has to be grounded tothe foundation earth connectorby customer. A foundation earthconnector should be provided bycustomer each 10 m or acc. tolocal requirements.

    * DIN VDE 0100 part 410 + 430 (not under permanent load) 3PH+N+PE(three-phase current) Note: Where a door is used to close the garage, themanufacturer of the door must be consulted before the electric cable is laid.

    Free spaces

    Maintenance

    Railings

    Recesses and conduits for rotaryswitches with rolling and sectional gates

    Protection against corrosion

    Dimensions

    Noise protection

    Temperature

    Drainage

    Conformity test

    Illumination

    BA

    BA

    A

    B

    8 8

    ====

    15

    Plastic or steel armoured conduit M 20

    Flexible plastic insulation pipe M 20

    Above plaster

    115 above access level

    Under plaster

    7

    min.20

    +0,5

    Basis is the German DIN 4109“Noise protection in buildings”.

    With the following conditionsrequired 30 dB (A) in roomscan be provided:

    – noise protection packagefrom our accessory

    – insulation figure of theconstruction of min. R’w = 57dB

    – walls which are borderingthe parking systems must bedone as single wall anddeflection resistant with min.m’= 300 kg/m2

    – solid ceiling above theparking systems with min.m’= 400 kg/m2

    At differing constructionalconditions additional soundabsorbing measures arenecessary.

    The best results are reachedby separated sole plates fromthe construction.

    Increased noise protection:

    If increased noise protectionmust be provided planning hasto be confirmed on a projectbasis by Wöhr (further buildingmeasures are required).

    The installation is designed to operate between +5°and +40°C.Atmospheric Humidity: 50% at +40°C. If the local circumstancesdiffer from the above please contact Wöhr.

    We recommend the provisionof a drainage channel at thefront of the pit which can eitherincorporate a pump sump50 x 50 x 20 cm, or a connectioninto the storm water sewerage

    system via a petrol/oil intercep-tor. To prevent any possibilityof contamination of the ground-water we recommend that thepit floor is coated with an oilproof paint.

    All our systems are checked according to EC machinery directive98/37/EG and EN 14010.

    Illumination has to be considered acc. to local requirements by client.

    The units need to be provided acc. EN ISO 13857 with safety railingsif the gap between unit and wall exceeds 20 cm. If walkways are arrangeddirectly to the side or behind the systems, railings have to be provided byclient acc. to local requirements, height min. 200 cm – this is applicableduring the construction phase too.

    Special drawings for free spaces to accommodate air ducts or otherpipes can be requested at Wöhr Agent!

    Regular maintenance by qualified personnel can be provided by meansof an Annual Service Contract.

    Independent of a maintenance workings has to be carried out acc. toWöhr Cleaning and Maintenance Instruction regularly.

    Clean up galvanized parts and platforms of dirt and road salt as wellas other pollution (corrosion danger)!

    Pit must be always ventilated and dearated well.

    All dimensions shown are minimum. Construction tolerances mustbe taken into consideration. All dimensions in cm.

    Notes

    Standard lowered cars can p ark only partly, if necessary additionaladjustments can be carried out.

  • 8/17/2019 Whoer Hydr Car Park.pdf

    15/451

       P   a   r   k   l   i   f   t   4   1   1

      ·   1   2 .   2

       0   0   8

      ·   C   0   2

       7  -   4   1   2   8

    Data Sheet WöhrParklift 411dependent parkingFor permanent user only!*

    Parklift 411 Standard type

    Width dimensions

    Parklift 411 Comfort type

    Notes

    1. Car width max. 190 cm. In case of special platform widths narrower than 230 and 460 cm respectively, the maximum vehicle width is reducedaccordingly. For cars with two outside mirrors, a minimum platform width of 250 cm or 500 cm is recommended.

    2. According to ISO 3864 the floor has to be marked with 10 cm wide yellow-black stripes at a distance of 50 cm from the platform edge by thepurchaser (see “statics and construction requirements“ on page 2).

    3. The lowering speed of an empty platform is considerably lower than a loaded one.

    4. The manufacturer reserves the right to modify or alter above specifications.

    * In case of short time user (e.g. for office-, hotel-, commercial building) only possible on lower platform and only if technicallyadjusted, ask WÖHR! Or with attendant or valet parking both levels are possible for short time user.

    Parklift 411-2 0: load per platform max. 2000kg (load per wheel max. 500 kg).

    Parklift 411-2 6: load per platform max. 2600kg (load per wheel max. 650 kg).

    Dimensions in cm

    min. 300 cmhorizontalmax. -10%slope

    520

    min.18

    h1

    15

    15

    w  a  l  l   o  p e n  i  n   g   f   o r  

    e l  e c  t  r  i  c  a  l   a  n  d  

    h  y  d  r  a  u  l  i  c   s  e r  v  i  c  e s  

    520

    min.18

    h1

    15

    15

    w  a  l  l   o  p e n  i  n   g   f   o r  

    e l  e c  t  r  i  c  a  l   a  n  d  

    h  y  d  r  a  u  l  i  c   s  e r  v  i  c  e s  

    Parklift Parklift Parklift411-155 411-165 411-175

    Height h1* double unit 330 340 350Height h1* single unit 320 330 340

    Car height lower level 150 160 170Car height upper level* 150 150 150

    * With greater h1 height, higher cars can be parked on theupper platform

    Parklift Parklift Parklift411-185 411-195 411-205

    Height h1* double unit 360 370 380Height h1* single unit 350 360 370

    Car height lower level 180 190 200Car height upper level* 150 150 150

    * With greater h1 height, higher cars can be parked on theupper platform

    clearplatform width

    B

    clearplatform width

    B

    Single unit Double unit

    * Special platform widthsare available (e.g. 210,220 cm), please check ifthey correspond withlocal regulations.

    * Special platform widthsare available (e.g. 420,430, 440, 450 cm),please check if theycorrespond withlocal regulations.

    Spacerequired gives clear

    B platform width*495 460515 480535 500

    Spacerequired gives clear

    B platform width*265 230275 240285 250295 260305 270

    We compact parking space

    Fon +49 [0] 7044 46-0Fax +49 [0] 7044 46-149

    [email protected]

    P. O. Box 115171288 Friolzheim/Germany

    Otto Wöhr GmbHAuto-Parksysteme

    Please attend to restricted car heights on upper platforms! Please attend to restricted car- and platform distance height on the lower parking

    space (Parklift 411-155 and Parklift 411-165)!

  • 8/17/2019 Whoer Hydr Car Park.pdf

    16/452

       P   a   r   k   l   i   f   t   4   1   1

      ·   1   2 .   2

       0   0   8

      ·   C   0   2

       7  -   4   1   2   8

    Installation diagram

    9 PVC control cable 5x 1,52 fromassembly to branch connector

    13 Operating device for UP/DOWNwith EMERGENCY-STOP. Ifpossible on the left, but alwaysoutside the platform’s movementrange. Cables always feed infrom below. (2 keys per parking place.)

    12 PVC control cable7 x1,52 from branchconnector to operatingelement

    11 PVC control cable 3 x1,52

    from branch connector

    to unlock magnet

    14 Unlock magnet

    10 Branchconnector

    7 PVC control cable 5x 1,52

    from main switch toassembly

    6 Lockable main switch

    3 Feed line to the main switch

    1 Electric meter

    8 Hydraulic unit with three-phasemotor, 230/400V, 50 Hz,1,5/3,0 kW. Switching cabinetwith motor, protection, wiredalready for installation

    16 PVC control cable 3 x1,52 frombranch connector to valve

    2 Fuse or automatic circuit breaker3 x16 A slow blow according toDIN VDE 0100 part 430

    15 Cylinder valve

    4 Foundation earth connector

    5 Equipotential bonding fromfoundation earth connectorto Parklift

    Notes

    Railings

    Hydraulic power packs

    For the accommodation of the hydraulic power packs an additional spaceis required which will be determinded during the verifications of thedrawings, e.g. in a wall recess.

    If walkways are arranged directly to the side or behind the systems, railingshave to be provided acc. EN ISO 13857 by client acc. to local requirements,height min. 200cm.

    Statics and construction requirements

    The units will be fixed on the anchor points with heavy duty anchor boltsto a depth of approx. 10–12cm.

    Base plate thickness minimum 18cm! Concrete quality C20/25.Special foundations are required with asphalt floors or paving-stones.

    In case of lower cars with spoilers, contact Company Wöhr or local agent(see “clearance profile“).

    * The total car height includes roof rail and antenna fixture must notexceed the mentioned max. height dimension.

    Clearance profile (standard car)

    10

    12060

    3814

    275 22

    46

    90max.290

    500

    48

    81626040

    40 150*(160*)(170*)(180*)(190*)(200*)

    Marking according to ISO 3864

    clearplatform

    width

    50

    clearplatform

    width+20

    160 170

    P2P1

    P1 P2

    P2P1

    P3

    300

    P3

    P3

    *all staticloadingsinclude theweightof the car

    411-2,0

    Singleunit

    Doubleunit

    P1 = + 5 kN*P2 = +16 kNP3 = + 3 kN

    411-2,6 411-2,6P1 = + 7kN* P1 = +14kNP2 = +19kN P2 =+33kNP3 = + 3 k N P3 = + 3 k N

    Electrical datas

    Item Performance Quantity Designation Position Frequency

    3 by customer as locally acc. to local power supply feed cable to 1 perrequired regulations main switch power pack

    3Ph+N+PE*

    1 by customer 1 unit electric meter in the feed cable

    2 by customer 1 unit fuse or automatic circuit in the feed cable 1 perbreaker 3x16A slow blow power packacc. to DIN VDE 0100 p. 430

    4 by customer each foundation earth corner pit floor/10 m connector rear wall

    5 by customer 1 unit equipotential bonding from foundation 1 peracc. to local requirements earth connector Parklift

    to Parklift

    Items 8–16 are included in Wöhr’s scope of delivery unless otherwise specified in theoffer/order.

    6 by customer 1 unit marked main switch, above operating 1 perlockable to prevent device power packunauthorized switching on

    7 by customer 10m PVC control cable with from main switch 1 permarked strands and pro- to hydraulic power power packtective conductor 5 x 1,52 pack

    The electrical componentssuppliedbythemanufacturermust be connected in accord-ance with the appropriate wiringdiagram and local regulations.

    German VDE electrical require-ments must be adhered to, inorder to validate the TÜV testedcircuit.

    The electrical supply to thepower pack(s) must be provided

    prior to or during installation toenable our fitters to completetheir work satisfactorily and tocheck the correct functioningof the units.

    Parklifts has to be grounded tothe foundation earth connectorby customer. A foundation earthconnector should be provided bycustomer each 10 m or acc. tolocal requirements.

    * DIN VDE 0100 part 410 + 430 (not under permanent load) 3PH+N+PE(three-phase current) Note: Where a door is used to close the garage, themanufacturer of the door must be consulted before the electric cable is laid.

    Noise protection

    Basis is the German DIN 4109“Noise protection in buildings”.

    With the following conditionsrequired 30 dB (A) in roomscan be provided:

    – noise protection packagefrom our accessory

    – insulation figure of the

    construction of min. R’w =57dB– walls which are bordering

    the parking systems must bedone as single wall anddeflection resistant with min.m’= 300 kg/m2

    – solid ceiling above theparking systems with min.m’= 400 kg/m2

    At differing constructionalconditions additional soundabsorbing measures arenecessary.

    The best results are reachedby separated sole plates fromthe construction.

    Increased noise protection:

    If increased noise protectionmust be provided planning hasto be confirmed on a projectbasis by Wöhr (further buildingmeasures are required).

    Temperature

    The installation is designed to operate between +5°and +40°C.Atmospheric Humidity: 50% at +40°C. If the local circumstancesdiffer from the above please contact Wöhr.

    Dimensions

    All dimensions shown are minimum. Construction tolerances mustbe taken into consideration. All dimensions in cm.

    Maintenance

    Protection against corrosion

    Regular maintenance by qualified personnel can be provided by meansof an Annual Service Contract.

    Independent of a maintenance workings has to be carried out acc. toWöhr Cleaning and Maintenance Instruction regularly.

    Clean up galvanized parts and platforms of dirt and road salt as wellas other pollution (corrosion danger)!

    Pit must be always ventilated and dearated well.

    Conformity test

    All our systems are checked according to EC machinery directive98/37/EG and EN 14010.

  • 8/17/2019 Whoer Hydr Car Park.pdf

    17/451

       P   a   r   k   l   i   f   t   4   1   3

      ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   3   0   4

    Data Sheet WöhrParklift 413Single unit = 3 cars Suitable for condominium and office buildings.Double unit = 6 cars For permanent use only!*

    Normal type

    Clearance profile (standard saloon/estate car) Examples (09.2008)

    Notes

    1. Car width max. 190 cm (see width details page 2). In case of special platform widths narrower than 230 and 460 cm respectively, the maximum vehiclewidth is reduced accordingly. For cars with two outside mirrors, a minimum platform width of 250 cm or 500 cm is recommended.

    2. Due to recent increases in car length dimensions, and potential future developments, a pit length of 540 cm is advisable.This offers bigger safety distances also for future cars.3. At the edge of the pit a 10cm wide, yellow-black marking according to ISO 3864 has to be provided by the purchaser

    (see “statics and construction requirements“ on page 3).4. The manufacturer reserves the right to modify or alter above specifications.

    The various model-series versions may vary insize and/or dimensionally, based on versionconfiguration, design and execution!

    Cars up to 150 cm/155 cm height:e.g. Audi A3 bis A6; BMW-Touring; Opel-Caravan; VW-Variant, always without roof rails

    Cars up to 170 cm/175 cm height:e.g. MB A-class, B-class; Fiat Tempra;VW New Beetle; Smart

    * The total car height includes roof rail and antenna fixture and must not exceed the mentionedmax. height dimension.

    Comfort type

    10

    22

    38

    2025

    90   55   162

    500120

    275

    60max.290   90

    46

    65   8

    14

    48 150/155*(170/175*)

    10

    12060   3814

    275 22

    46

    90max.290500

    48

    81626040

    40 150/155*(170/175*)

    A B C h car height*

    Parklift 413-335/330: 335 330 480 155 150

    Parklift 413-345/340: 345 340 495 160 155

    * upper level, entrance level and lower level for saloon and estate cars

    A B C h car height*

    Parklift 413-375/370: 375 370 540 175 170

    Parklift 413-385/380: 385 380 555 180 175

    * upper level, entrance level and lower level for saloon and estate cars

    C

    B+3

    0A+3

    0

    +30

    A+3

    0

    C

    B+3

    0

    +30

    40

    min.18

    530–540

    70

    h

    38

    10

    15

    6050

    15

    25

    25

    X

    50

    free space for door

    clear heightfor a lintel

    free space

    Dimensions in cm

    All platforms are in a horizontalposition to drive on.

    Covered installation:Load per platform max. 2000 kg(load per wheel max. 500 kg)

    = only applicable ifgarage doors areto be fitted

    Roller doors:= 15

    Sectional doors:= 25 (single doors)= 30 (double doors)

    = to be clarified withdoor supplier

    X

    XX

    X

    X

    2%   2%

    max. + 3% slopemax. -10% slope

      p  o  s  s   i   b   l  e

       c   h  a

      n  n  e   l

       1  0  x  2

       p   l  u

      s

      r  e  c  e

      s  s   f  o  r   s

      u  m  p   p  u

      m  p   5  0

      x  5  0  x  2  0

     w a l l  o p

     e n i n g   f o

     r

     e l e c t r i c

     a l  a n d

     h y d r a u

     l i c  s e r v i

     c e s

      p  o  s  s  i   b   l  e

       s  p  a  c

      e

      f  o  r   s

      u  c  t  i  o

      n

    * In case of short time user– only possible on upper platformand only if technically adjusted,ask WÖHR!Or with attendant or valet parking alllevels are possible for short time user.

    We compact parking space

    Fon +49 [0] 7044 46-0Fax +49 [0] 7044 46-149

    [email protected]

    P. O. Box 115171288 Friolzheim/Germany

    Otto Wöhr GmbHAuto-Parksysteme

    Please attend torestricted car- andplatform distanceheight!

  • 8/17/2019 Whoer Hydr Car Park.pdf

    18/452

       P   a   r   k   l   i   f   t   4   1   3

      ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   3   0   4

    Width dimensions · Underground garages

    Wall to wall

    Pillars outside pit

    Pillars inside pit

    Important notes

    All dimensions shown are minimum. Construction tolerances must be taken into consideration.All dimensions in cm.

    The access to the Parklift is possible with max. 3% declination and max. 10% inclination.

    If not stated differently in the of fer, platform widths of 230 cm or 460 cm will be delivered. Bigger/smaller platform widths can be deliveredat additional price.

    Cars wider than 190 cm should be parked on platforms270/500 cm width only.For spaces against walls, or at end of rows, werecommend that largest possible platform widths areutilized to assist turning motion.

    If maximum platform widths are not installed, difficulties mightarise when entering or exiting the cars on the parking units.This depends on the car type, the access and the individualdriving behaviour.

    Space requiredB

    gives clearplatform width

    270280290300310

    230240250260270

    Space requiredB

    gives clearplatform width

    500520540

    460480500

    gives clearplatform width

    765795825835845

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Space requiredB

    Wall openings required betweenpartitions for electrical and hydraulicconduits must be provided whereapplicable. Wall openings may not

    be closed after installation.

    Single unit (3 cars)

    B

    S

    Double unit (6 cars)

    B

    D

    Combinated unit (9 cars)

    B

    D S

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    260 245

    270 255280 265290 275300 285

    230

    240250260270

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    490 475

    510 495530 515

    460

    480500

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    750 740

    780 770810 800820 810830 820

    460+230

    480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Single unit (3 cars)

    B

    S S

    B1

    min. 20

    Double unit (6 cars)

    B

    D

    B1

    min. 20D

    Combinated unit (9 cars)

    B

    D

    B1

    min. 20S D S

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    260 245270 255280 265290 275300 285

    230240250260270

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    490 475510 495530 515

    460480500

    Space requiredwall- pillar-pillar pillar

    B B1

    gives clearplatform width

    750 740780 770810 800820 810830 820

    460+230480+240500+250500+260500+270

    Further width combinations as well as smaller widths are possible

    Minimum drivewaywidth according tolocal requirements

    Single unit (3 cars)

    B

    S S

    B1

    min. 20

    max.140

    Double unit (6 cars)

    B

    D

    B1

    min. 20

    max.140

    D

    Combinated unit (9 cars)

    B

    D

    B1

    min. 20

    max.140

    S D S

  • 8/17/2019 Whoer Hydr Car Park.pdf

    19/45

  • 8/17/2019 Whoer Hydr Car Park.pdf

    20/454

       P   a   r   k   l   i   f   t   4   1   3

      ·   0   9 .   2

       0   0   8

      ·   C   0   2   7  -   4   3   0   4

    Electrical datas Installation diagram

    Item Performance Quantity Designation Position Frequency

    3 by customer as locally acc. to local power supply feed cable to 1 perrequired regulations main switch power pack

    3Ph+N+PE*

    1 by customer 1 unit electric meter in the feed cable

    2 by customer 1 unit fuse or automatic circuit in the feed cable 1 perbreaker 3 x 25 A slow blow power packacc. to DIN VDE 0100 p. 430

    4 by customer each foundation earth corner pit floor/10 m connector rear wall

    5 by customer 1 unit equipotential bonding from foundation 1 peracc. to local requirements earth connector Parklift

    to Parklift

    Items 8–14 are included in Wöhr’s scope of delivery unless otherwise specified in theoffer/order.

    6 by customer 1 unit marked main switch, above operating 1 perlockable to prevent device power packunauthorized switching on

    7 by customer 10m PVC control cable with from main switch 1 permarked strands and pro- to hydraulic power power packtective conductor 5x 2,52 pack

     4 Foundation earth connector 5 Equipotential bonding from  foundation earth connector  to Parklift

      3 Feed line to the main switch

      1 Electric meter  2 Fuse or automatic circuit breaker 3 x 25A slow blow  according to DIN VDE 0100 part 430

      6 Lockable main switch  7 PVC control cable 5 x 2.52  from main switch to assembly

      8 Hydraulic unit with three-phase  motor, 230/400 V, 50Hz, 5.5 kW.  Switching cabinet with motor,  protection, wired already for  installation

      9 PVC control cable 5 x1.52

    10 Branch connector

    14 Cylinder valve cablePVC control cable 3 x1.52

    11 PVC control cable 5x1.52

      to the next facility12 Operating device for UP/DOWN withEMERGENCY-STOP. If possible on theleft, but always outside the platform’smovement range. Cables always feed infrom below. (2 keys per parking place.)

    13 PVC controlcable 7 x1.52

    conduit

    120 cm 110 cm

    conduit

    The electrical componentssuppliedbythemanufacturermust be connected in accord-ance with the appropriate wiringdiagram and local regulations.

    German VDE electrical require-ments must be adhered to, inorder to validate the TÜV testedcircuit.

    The electrical supply to thepower pack(s) must be provided

    prior to or during installation toenable our fitters to completetheir work satisfactorily and tocheck the correct functioningof the units.

    Parklifts has to be grounded tothe foundation earth connectorby customer. A foundation earthconnector should be provided bycustomer each 10 m or acc. tolocal requirements.

    * DIN VDE 0100 part 410 + 430 (not under permanent load) 3PH+N+PE(three-phase current) Note: Where a door is used to close the garage, themanufacturer of the door must be consulted before the electric cable is laid.

    Free spaces

    Maintenance

    Railings

    Recesses and conduits for rotaryswitches with rolling and sectional gates

    Protection against corrosion

    Dimensions

    Noise protection

    Temperature

    Drainage

    Conformity test

    Illumination

    BA

    BA

    A

    B

    8 8

    ====

    15

    Plastic or steel armoured conduit M 20

    Flexible plastic insulation pipe M 20

    Above plaster

    115 above access level

    Under plaster

    7

    min.20

    +0,5

    Basis is the German DIN 4109“Noise protection in buildings”.

    With the following conditionsrequired 30 dB (A) in roomscan be provided:

    – noise protection packagefrom our accessory

    – insulation figure of the

    construction of min. R’w = 57dB– walls which are bordering

    the parking systems must bedone as single wall anddeflection resistant with min.m’= 300 kg/m2

    – solid ceiling above theparking systems with min.m’= 400 kg/m2

    At differing constructionalconditions additional soundabsorbing measures arenecessary.

    The best results are reachedby separated sole plates fromthe construction.

    Increased noise protection:

    If increased noise protectionmust be provided planning hasto be confirmed on a projectbasis by Wöhr (further buildingmeasures are required).

    The installation is designed to operate between +5°and +40°C.Atmospheric Humidity: 50% at +40°C. If the local circumstancesdiffer from the above please contact Wöhr.

    We recommend the provisionof a drainage channel at thefront of the pit which can eitherincorporate a pump sump50 x 50 x 20 cm, or a connectioninto the storm water sewerage

    system via a petrol/oil intercep-tor. To prevent any possibilityof contamination of the ground-water we recommend that thepit floor is coated with an oilproof paint.

    All our systems are checked according to EC machinery directive98/37/EG and EN 14010.

    Illumination has to be considered acc. to local requirements by client.

    The units need to be provided acc. EN ISO 13857 with safety railingsif the gap between unit and wall exceeds 20 cm. If walkways are arrangeddirectly to the side or behind the systems, railings have to be provided byclient acc. to local requirements, height min. 200 cm – this is applicableduring the construction phase too.

    Special drawings for free spaces to accommodate air ducts or otherpipes can be requested at Wöhr Agent!

    Regular maintenance by qualified personnel can be provided by meansof an Annual Service Contract.

    Independent of a maintenance workings has to be carried out acc. toWöhr Cleaning and Maintenance Instruction regularly.

    Clean up galvanized parts and platforms of dirt and road salt as wellas other pollution (corrosion danger)!

    Pit must be always ventilated and dearated well.

    All dimensions shown are minimum. Construction tolerances mustbe taken into consideration. All dimensions in cm.

  • 8/17/2019 Whoer Hydr Car Park.pdf

    21/451

       P   a   r   k   l   i   f   t   4   3   0

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   4   1   4   0

    We compact parking space

    Fon +49 [0] 7044 46-0Fax +49 [0] 7044 46-149

    [email protected]

    P. O. Box 115171288 Friolzheim/Germany

    Otto Wöhr GmbHAuto-Parksysteme

    Data Sheet WöhrParklift 430Single unit = 2 cars Suitable for condominium and office buildings.Double unit = 4 cars For permanent use only!*

    Clearance profile (standard saloon/estate car)

    Notes1. Car width max. 190 cm (see width details page 2). In case of special platform widths narrower than 230 and 460 cm respectively, the maximum vehicle

    width is reduced accordingly. For cars with two outside mirrors, a minimum platform width of 250 cm or 500 cm is recommended.

    2. Due to recent increases in car length dimensions, and potential future developments, a pit length of 540cm is advisable.This offers bigger safety distances also for future cars

    3. At the edge of the pit a 10cm wide, yellow-black marking according to ISO 3864 has to be provided by the purchaser(see “statics and construction requirements“ on page 3).

    4. The manufacturer reserves the right to modify or alter above specifications.

    10

    22

    38

    20

    25

    90   55   162

    500

    120

    275

    60

    max.290   90

    46

    65   8

    14

    48

    150

    bis195*

    13

    12060

    3814

    275 22

    46

    90max.290500

    48

    81627540

    37

    150bis

    195*

    * The total car height includes roof rail and antenna fixture and must not exceed the mentioned max. height dimension.

    min.18

    25

    free space

    max. +2% slopemax. –2% slope

    25

    40

    40 80

    40

    530–540

    clear heightfor a lintel

    70

    X

    free spacefor door

    Dimensions in cm

    = to be clarified with  door supplier

    X

    * In case of short time use– only possible on upper platformand only if technically adjusted,ask WÖHR!

    Or with attendant or valet parkingboth levels are possible for shorttime user.

    Load per platform max. 2000 kg(load per wheel max. 500 kg)

    = only applicaple if garage  doors are to be fitted.  For roller doors x = 10/15 cm

    X

    15

    15

    390

    80

    2%   2%

    50

    min. 295

    150to

    195

    +30

    +30

    155to

    200

    +30

    +30

       p  o  s  s    i    b    l  e

       c    h

      a   n   n  e    l   1

       0   x   2   p   l

      u  s

      r  e  c  e

      s  s    f  o  r   s

      u  m  p   p  u

      m  p    5   0

       x   5   0

       x   2   0

     w a l l  o p

     e n i n g   f o

     r

     e l e c t r i c

     a l  a n d

     h y d r a u

     l i c  s e r v

     i c e s

      p  o  s  s

      i   b   l  e   s  p

      a  c  e

      f  o  r   s

      u  c  t  i  o

      n

    +30

    We suggest to plan with min. car heights of 165 cm resp. platform distances of min. 170 cm!

  • 8/17/2019 Whoer Hydr Car Park.pdf

    22/452

       P   a   r   k   l   i   f   t   4   3   0

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   4   1   4   0

    Possible adjustemts

    Pit depth 1,55 m | Height above entrance level 2,95 m

    Pit depth 1,55 m | Height above entrance level 3,25 m

    Pit depth 1,70 m | Height above entrance level 2,95 m

    Pit depth 1,70 m | Height above entrance level 3,25 m

    For different dimensions please contact WOHR!

    * = platform slope during use 8° (14,1%)

    150155

    295

    530

    150155

    325

    530

    150155

    325

    530

    165170

    295

    530

    165170

    325

    530

    165170

    325

    530

    165170

    325

    530

    only saloon cars up to 1,50 m heigth, inclined*

    saloon/estate cars up to 1,50 m heigth, inclined*

    upper level

    lower level

    saloon/estate cars up to 1,50 m heigth, inclined*

    saloon/estate cars up to 1,50 m heigth, horizontal

    saloon/estate cars up to 1,65 m heigth, inclined*

    saloon/estate cars up to 1,50 m heigth, inclined*

    upper level

    lower level

    saloon/estate cars up to 1,50 m heigth, horizontal

    saloon/estate cars up to 1,50 m heigth, horizontal

    saloon/estate cars up to 1,65 m heigth, horizontal

    saloon/estate cars up to 1,50 m heigth, inclined*

    saloon/estate cars up to 1,50 m heigth, inclined*

    saloon/estate cars up to 1,65 m heigth, inclined*

    upper level

    lower level

    only saloon cars up to 1,50 m heigth, horizontal

    saloon/estate cars up to 1,50 m heigth, inclined*

    upper level

    lower level

  • 8/17/2019 Whoer Hydr Car Park.pdf

    23/453

       P   a   r   k   l   i   f   t   4   3   0

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   4   1   4   0

    Pit depth 1,85 m | Height above entrance level 3,20 m

    Pit depth 1,85 m | Height above entrance level 3,40 m

    Pit depth 2,00 m | Height above entrance level 3,35 m

    Pit depth 2,00 m | Height above entrance level 3,55 m

    Possible adjustemts

    For different dimensions please contact WOHR!

    * = platform slope during use 8° (14,1%)

    180185

    320

    530

    180185

    340

    530

    180185

    340

    530

    180185

    340

    530

    195200

    335

    530

    195200

    355

    530

    195200

    355

    530

    195200

    355

    530

    195200

    355

    530

    only saloon cars up to 1,65 m heigth or

    estate cars up to 1,50 m heigth, horizontal

    saloon/estate cars up to 1,65 m heigth, inclined*

    upper level

    lower level

    only saloon cars up to 1,65 m heigth or

    estate cars up to 1,50 m heigth, horizontal

    saloon/estate cars up to 1,80 m heigth, inclined*

    upper level

    lower level

    saloon/estate cars up to 1,50 m heigth, horizontal

    saloon/estate cars up to 1,80 m heigth, horizontal

    only saloon cars up to 1,80 m heigth or

    estate cars up to 1,65 m heigth, horizontal

    saloon/estate cars up to 1,80 m heigth, inclined*

    only saloon cars up to 1,65 m heigth or

    estate cars up to 1,50 m heigth, inclined*

    saloon/estate cars up to 1,95 m heigth, inclined*

    upper level

    lower level

    saloon/estate cars up to 1,50 m heigth, horizontal

    saloon/estate cars up to 1,65 m heigth, horizontal

    saloon/estate cars up to 1,65 m heigth, horizontal

    saloon/estate cars up to 1,65 m heigth, inclined*

    saloon/estate cars up to 1,50 m heigth, inclined*

    saloon/estate cars up to 1,80 m heigth, inclined*

    upper level

    lower level

    saloon/estate cars up to 1,80 m heigth, horizontal

    saloon/estate cars up to 1,50 m heigth, horizontal

    upper level

    lower level

  • 8/17/2019 Whoer Hydr Car Park.pdf

    24/454

       P   a   r   k   l   i   f   t   4   3   0

      ·   0   9 .   2

       0   0   8

      ·   C   0

       2   7  -   4   1   4   0

    Width dimensions · Underground garages

    Wall to wall

    Pillars outside pit

    Pillars inside pit

    Important notes

    All dimensions shown are minimum. Construction tolerances must be taken into consideration.All dimensions in cm.

    The access to the Parklift is possible with max. 2% declination and max. 2% inclination.

    If not stated differently in the of fer, platform widths of 230cm or 460cm will be delivered. Bigger/smaller platform widths can be deliveredat additional price.