SERVICE Whirlpool Europe Customer Services Model AWM 6102 Version 8570 610 10490 Page Technical data 2 - 3 Spare part list 4 Exploded view 5 - 6 Wiring diagram 7 Circuit diagram 8 Program chart 9 - 14 Text/Legend 15 - 17 Family SC1 Service Manual Washing machine Frontloader AWM 6102 AWM 6102 This documentation is only intended for qualified technicians who are aware of the respec- tive safety regulations. Date: 26.08.2004 Subject to modification Document-No.: 4812 722 23243
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
S E R V I C EWhirlpool Europe
Customer Services
Model AWM 6102 Version 8570 610 10490 Page
Technical data 2 - 3
Spare part list 4
Exploded view 5 - 6
Wiring diagram 7
Circuit diagram 8
Program chart 9 - 14
Text/Legend 15 - 17
Family SC1
Service ManualWashing machineFrontloaderAWM 6102
AWM 6102
This documentation is only intended for qualified technicians who are aware of the respec-tive safety regulations.Date: 26.08.2004 Subject to modificationDocument-No.: 4812 722 23243
S E R V I C E26.08.2004 / Page 2 AWM 6102 Whirlpool EuropeDoc. No: 4812 722 23243 8570 610 10490 Customer Service
Technical data
Dimensions
Height 81.5 - 84 cmWidth 59.5 cmDepth 57.3 cm
Weight
Net weight ~72 kgWith package ~74 kg
Main Connection
Voltage 230 V ± 10%Frequency 50 HzPower consumption ~2.3 kWFuse rating 10 A
Cotton/coloured 5 kgCotton rapid 3 kgCotton short 5 kgEasy care 2.5 kgEasy care rapid 1.5 kgEasy care short 2.5 kgDelicate 1.5 kgWool 1 kgHandwash/Silk 1 kgDaily 3 kg
Pressostat
Kind of switch 1-level pressoswitchwith overflow contact
Type 760/B1-223Nominal voltage 230 V
Water Level
Level 1 (11 - 12, 14)Switching point 60 ± 5 mmWcSwitching back point 35 ± 5 mmWc
Water temperature <90 ˚CRated flow >1 bar 8 l/min ± 10%Pressure range 0.2 - 10 barNominal voltage 220 - 240 VFrequency 50 HzNominal current 35 mANominal power 6 W ± 10%Nominal resistance 3.8/4.0 kΩ ± 10%
S E R V I C EWhirlpool Europe AWM 6102 26.08.2004 / Page 3Customer Service 8570 610 10490 Doc. No: 4812 722 23243
Technical data
Drain pump (synchronous)
Type 72735Nominal power 34 WNominal/max. current 0.3/0.5 ARotation speed 3000 rpmResistor (coil) (20 ˚C) 155 ΩCapacity (0.55 - 1.0 m) 14 ± 2 l/minOverheating protection no
Program timer
Type SC1 - 3334Timer basic 4619 710 67636Timer programmed 4619 751 52751Nominal voltage 230 VFrequency 50 HzPositions 32
Washing 190 W ± 7%Rinsing 260 W ± 7%Spinning 360 W ± 10%
Radio interference supression
Rated voltage 250 VRated current 16 AFrequency 50 HzNominal capacity 240/250nFX1+2x22nFY
± 20%Nominal resistance 1000 kΩ ± 5%Derivation current(u = 250 V AC) ≤ 4.15 (2 x 2.075) mA
Display module
Type 3952 J4619 710 67203
Nominal voltage 230 +10%,-15% VConnection RAST 2.5Combination part of:
1 PCB with 1 micro-controller1 selector (for select programs and main switch)LEDs with lightguidesswitches (for select options and spin speed)2 digits (for temperature selection)