Top Banner
WLSA CONVERGENCE SUMMIT “SMARTPHONE PLATFORM SURVEY-SCALE HEART RATE COLLECTION – A PERFORMANCE EVALUATION IN ETHIOPIA” JAMES A. J. HEATHERS PH.D., UNIVERSITY OF SYDNEY
23

WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

Jun 19, 2015

Download

Healthcare

Wireless Health 2014 Conference Technical Session 6 featuring speaker James Heathers.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

WLSACONVERGENCE SUMMIT

“SMARTPHONE PLATFORM SURVEY-SCALE HEART RATE COLLECTION – A PERFORMANCE EVALUATION IN ETHIOPIA”

JAMES A. J. HEATHERSPH.D., UNIVERSITY OF SYDNEY

Page 2: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

Ph.D., University of SydneyJAMES A. J. HEATHERS

“Smartphone Platform Survey-Scale Heart Rate Collection – a Performance Evaluation in Ethiopia”

Page 3: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

3

WHAT IS HRV?

Page 4: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

4

PROBLEMS WITH HRV

Page 5: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

5

PROBLEMS WITH HRV

HRV NOW:

• POORLY CONTROLLED• SMALL SAMPLE SIZE

Page 6: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

6

TWO BETTER MODELS:

1. CAREFUL EXPERIMENTAL CONTROL

2. MASSIVELY INCREASED SAMPLE SIZE

PROBLEMS WITH HRV

Page 7: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

7

TWO BETTER MODELS:

1. CAREFUL EXPERIMENTAL CONTROL

2. MASSIVELY INCREASED SAMPLE SIZE

PROBLEMS WITH HRV

Page 8: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

8

IDEAL MASS COLLECTION:

• Accurate• Robust• Cheap• Components

• Off shelf• Swappable

THE NEW SYSTEM

Page 9: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

9

THE NEW SYSTEM

• iOS device (iPod, iPad etc.)

• Hardware switching box

• Optical finger sensor (PPG)

• www.myithlete.com

A/DBandpassfilter

d/dtPeak

detectTime

stamp

Sensor

iPod/iPhone

Logfile

HRV

Page 10: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

10

HEATHERS et al (2012); HEATHERS (2014b)

Is pulse rate accurate enough to measure HRV?

Yes.

PROBLEMS WITH HRV

Page 11: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

11

HEATHERS (2013);HEATHERS (2014a)

Is this system accurate enough to support HRV?

Yes.

PROBLEMS WITH HRV

Page 12: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

12

“The International Food Policy Research Institute (IFPRI) seeks sustainable solutions

for ending hunger and poverty.”

THE IFPRI

Page 13: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

13

HRV in Development Economics

• HRV as stress correlate (in realistic sample)

• HRV as predictor of program success or covariate

• HRV as control against response bias

THE IFPRI

Page 14: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

14

TWO PURPOSES

1. FIELD TRIAL, IN CONTEXT

2. PROPERTIES OF MASSIVELY INCREASING SAMPLE SIZE

EXPERIMENT

Page 15: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

15

PARAMETERS• 17 enumerators (locals, no research experience)

EXPERIMENT

Page 16: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

16

PARAMETERS• 20 iPod Touch + extra sensors

EXPERIMENT

Page 17: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

17

PARAMETERS• 6 supervisors

EXPERIMENT

Page 18: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

18

PARAMETERS• Animated indicators on phone

EXPERIMENT

Page 19: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

19

SAMPLE

• N=679• n=1205 recordings• 91.7% usability (93.3% in new sample)

RESULTS

Page 20: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

20

OUTCOMES

• Age/gender relationships as expected

• Relationship with alcohol consumption (analogue of self-control?)

RESULTS

Page 21: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

21

ONGOING:

• Correlate of food-aid program (n=1142), still analysing

• Largest HRV study ever… (presently n=3408)

RESULTS

Page 22: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

22

PAPER

Page 23: WH2014 Session: Smartphone platform survey-scale heart rate collection – a performance evaluation in ethiopia

WLSACONVERGENCE SUMMIT

www.wirelesshealth2014.org