Product Catalogue www.powerclad.com PRODUCT SELECTOR POWERCLAD ALL SCAFFOLD SYSTEMS MODULAR TEMPORARY ROOF SYSTEMS TEMPORARY FENCING SYSTEMS BANNERS & BUILDING WRAPS FLAME RETARDANT AIR PERMEABLE TEMPERATURE CONTROL NOISE CONTROL CUSTOM PRINTING SCAFFOLD SHEETING P P P P VENTED SHEETING P P P P P P DEBRIS NETTING P P P INSULATED SHEETING P P SOUND BARRIER P P P P P P FILTER SHEETING P P P KEDER SHEETING P P P TEMPORARY ROOF SHEETING P PVC BANNER P P P P P AIR MESH P P P APPLICATION FEATURES Specialists in flame retardant materials POWERCLAD ® Weather protection & containment solutions POWERCLAD ®
8
Embed
Weather protection & containment solutions Product Catalogue … · 2019-06-29 · product catalogue product selector powerclad all scaffold systems modular temporary roof systems
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Product Catalogue www.powerclad.com
PRODUCT SELECTOR
POWERCLAD ALL SCAFFOLD SYSTEMS
MODULAR TEMPORARY
ROOF SYSTEMS
TEMPORARY FENCING SYSTEMS
BANNERS & BUILDING
WRAPS
FLAME RETARDANT
AIR PERMEABLE
TEMPERATURE CONTROL
NOISE CONTROL
CUSTOM PRINTING
SCAFFOLD SHEETING P P P PVENTED SHEETING P P P P P PDEBRIS NETTING P P PINSULATED SHEETING P PSOUND BARRIER P P P P P PFILTER SHEETING P P PKEDER SHEETING P P PTEMPORARY ROOF SHEETING PPVC BANNER P P P P PAIR MESH P P P
Minimum tensile strength(both machine and cross direction) 630 N/50mm
Minimum eyelet strength 500 N
Minimum attachment fastener strength 500 N
BS 7955 Compliance Containment nets and sheets on construction works. Specification for perfomance and test methods
PRODUCT COMPLIANCE SUMMARY Contract ValueJoint Code of Practice on the Protection from Fire of Construction Sites and Buildings Undergoing Renovation (JCC)
BS 7955Compliant
Flame retardancy third party approval
required
<£2.5million Risk assessment shows flame retardant sheeting not required
P NA
<£2.5milliona. Risk assessment: FR sheeting recommended OR b. contract is part of a larger project
P a. Recommendedb. Yes
>£2.5million P Yes
POWERCLAD® SCAFFOLD SHEETINGReinforced sheeting with flame retardant grades
Reinforced polyolefin sheeting Strong reinforcement bands with eyelets every 10 cm Flame retardant grades have third party approval to the highest
standards (LPS 1215, LPS 1207) for both printed and non-printed
For all tube & fitting and modular scaffold systems
For all tube & fitting and modular scaffold systems
Knitted netting for temporary containment Flame retardant grade to BS 476 Part 12C
FR Premium 240 gsm P2.0 x 45, 2.2 x 40, 2.7 x 20, 3.0 x 45, 3.2 x 20, 4.0 x 45
FR Standard 170 gsm P2.0 x 45, 2.2 x 40, 3.0 x 45, 3.2 x 20
Standard XL 180 gsm P 4.0 x 45
Standard 170 gsm NA2.0 x 45, 2.2 x 40,
3.0 x45
Lite 150 gsm NA 2.0 x 45
Strong sheeting with high air permeability Suitable for scaffolding systems and temporary fencing Flame retardant grade to BS 476 Part 12C FR Vented Sheeting available in both white and black
For all scaffold systems and temporary perimeter fencing
POWERCLAD Weight BS 7955Compliant
Sizes(metres)
FR Vented 100 gsm P 2.0 x 45
Vented 100 gsm P 2.0 x 453.0 x 45
POWERCLAD Colour Sizes(metres)
FR Debris Netting White2.0 x 503.0 x 50
Debris Netting Green, Blue Red, Yellow, Orange, Pink, Black
POWERCLAD® FILTER SHEETINGFlame retardant closely woven air permeable mesh
Closely woven air permeable mesh Particularly suitable for exposed locations with high winds Compliant to BS 7955 Flame retardant to BS 476 Part 12C
For all tube & fitting and modular scaffold systems
For most temporary roof systems Available with keder hems or reinforced bands Compliant to BS 7955 Strong, tear-resistant reinforcement strips for fastening the
sheeting
POWERCLAD® TEMPORARY ROOF SHEETING Sheeting with strong reinforcement strips
For noise-sensitive construction sites Reinforced PVC with an acoustic foam insulate layer Waterproof outer layer for weather protection Flame retardant to BS 476 Part 12C Excellent heat retention Independently tested for acoustic performance to BS EN ISO 717-1 Sound reduction of up to 16dB Lightweight for easy installation Custom printing
For all scaffold systems and temporary perimeter fencing
Closely woven air permeable mesh Superior material for custom printing
For temporary perimeter fencing
PVC BANNERS AIR MESHCustom-printed fencing panels
For scaffolding systems & temporary fencing
Dip coated PVC mesh and coated reinforced PVC
POWERCLAD® INSULATED SHEETINGSheeting for insulation in hot and cold climates
Incorporates air cells to provide thermal insulation Excellent light transmission Compliant to BS 7955 Flame retardant grade to DIN 4102 B1
For all tube & fitting and modular scaffold systems
POWERCLAD Weight BS 7955Compliant
Sizes(metres)
FR Insulated Sheeting 370 gsm P 2.0 x 20, 2.2 x 20, 2.7 x 20
Insulated Sheeting 345 gsm P 2.0 x 20, 2.2 x 20, 2.7 x 20
For large and small printed banners
POWERCLAD Weight BS 7955Compliant
Sizes(metres)
FR Sound Barrier 1600 gsm P 2.0 x 1.2, 2.0 x 3.5, 2.2 x 10