Water Transmission Group Bar-Wrapped Concrete Cylinder Pipe (CCP)
Introduction
CCP, A COMPOSITE STRUCTURE THAT COMBINES THE ADAPTABILITY OF STEEL WITH THE DURABILITY AND CORROSION INHIBITING PROPERTIES OF CONCRETE AND CEMENT MORTAR, AND, IT’S CUSTOM DESIGNED TO YOUR SYSTEM NEEDS.
Bar-Wrapped Concrete Cylinder Pipe (CCP) consists of a steel cylinder lined with concrete or cement mortar, then helically wrapped with a mild steel bar and coated with dense cement mortar. Several easily assembled watertight joints are shown on the next page.
Since introducing the product in 1942, Ameron has supplied more than 6,000 miles of CCP for piping systems in the United States and throughout the world. Principal uses have been for the transmission and distribution of water in municipal, industrial and agricultural systems. CCP can be used to convey any liquid not corrosive to concrete, including seawater and sewage in force mains.
CCP is designed and manufactured in accordance with American Water Works Association (AWWA) Standard C303 and AWWA Manual M9, and is normally supplied in standard diameters of 18 to 72 inches for operating pressures up to 400 psi. Pipe has been manufactured in larger sizes and for higher pressures based on the concepts of this standard.
Quality Assurance
The national standard for Bar-Wrapped Concrete Cylinder Pipe is AWWA C303. This standard requires that every manufacturer maintain a quality assurance program, and that all materials used to manufacture the pipe conform to American Society for Testing and Materials (ASTM) standards. Welding procedures and welding inspection, as well as the welding operators and welders, must be qualified under nationally recognized standards. Quality assurance checks must be completed at every manufacturing process, including tests on the steel, the welds, the pipe lining and coating, and hydrostatic testing of the cylinders.
Ameron’s customers have requested well developed standards and consistently high quality products. So, in addition to maintaining our own quality assurance department, we require that Lloyd’s Register, the world’s premier classification society, annually audit each of our plants certifying that they are in compliance to the national standard.
The combination of Ameron’s commitment to its customers, the AWWA C303 standard, certifications from ISO 9001, Lloyd’s Register and National Science Foundation (NSF) verify to you that when Ameron’s Bar-Wrapped Concrete Cylinder pipe is delivered to your jobsite, it conforms to your specifications and is of consistent quality.
A Concrete or Cement Mortar Lining
B Dense Cement Mortar Coating
C Bar-wrapped Reinforcement*
D Round Rubber Gasket
E Steel Joint Rings*
F Steel Cylinder*
G Polyethylene foam-lined grout band
H Field applied cement mortar
* Mild Steel Components
Water Transmission Group Bar-Wrapped Concrete Cylinder Pipe (CCP)
Optimum Design
CCP is designed to resist internal hydrostatic pressure by a combination of the steel cylinder and helically wound bar. Thus, the pipe can be custom designed to provide the exact amount of steel needed for pipeline operating conditions by selecting the optimum combination of steel cylinder thickness, and bar diameter and spacing. This flexibility in design can result in substantial cost savings.
Significance of Bar Wrapping
After the lining is cured, the steel cylinder is helically wrapped with a continuous mild steel bar applied at a tensile stress of 8,000 to 10,000 psi. The bar wrapping provides the balance of steel required to resist tensile hoop forces. In addition, the bar wrapping reinforces the mortar coating and locks it tightly against the steel cylinder so that cylinder, bar and coating act as a composite structure. This composite construction greatly increases the pipe’s rigidity, beam strength, and resistance to impact and vacuum.
Carrying Capacity
Field studies have proven that a Hazen-Williams coefficient, C, design value of 140, will be maintained over the service life of your project.
Corrosion Protection
The cement mortar coating maintains the steel elements in a highly alkaline environment, typically pH of 12.5 or greater. In this alkaline environment, galvanic corrosion is inhibited. The cured, shop-applied mortar coating must pass a water-absorption test that limits the average absorption value for any ten consecutive tests to 9% with no individual test exceeding a value of 11%. This dense mortar coating, along with the rich cement slurry which is applied to coat the portion of the bar bearing against the cylinder, provides a corrosion inhibiting and passivating environment for the steel cylinder and the bar wrap.
Field Assembly
The self-centering steel bell and spigot joint sealed with a confined rubber ring and the long laying length permit CCP to be installed rapidly and economically. Laying rates of 30 to 50 pipe sections per day per crew are readily attained. The reliability of the joint sealed with a confined rubber gasket has been proved by more than 70 years of trouble-free performance.
Customized Pipeline Design
Ameron provides a complete engineering package for each CCP project, including pipe design calculations, pipeline layout drawings and fabrication details for each component. As part of a custom-designed system, special pipe and fittings are numbered to identify their location in the pipeline.
Restraint of Thrust
Hydraulic thrust in the pipeline can be resisted by appropriately field welding the joint of assembled pipe sections to develop the required longitudinal restraint.
Field Pressure Tapping
CCP can be economically tapped while in service with commercially available equipment and procedures, permitting the installation of a full range of outlets in any diameter pipe.
Standard CCP Joint
Placing rubber gasket on the Carnegie Spigot end of pipe
Carnegie Spigot with Expanded Bell
INSIDE OROUTSIDEOPTIONAL
Wrapping bar on to steel cylinder
Lap Welded Joint
Pipe Design
The total cross-sectional area of the circumferential steel reinforcement (steel cylinder plus bar reinforcement) is:
Each cylinder is hydrostatically tested after joint rings are attached.
Pipe Diameter Range Minimum Cylinder Thickness
inches gage* inches**
18-21 16 0.060
24-33 14 0.075
36-39 13 0.090
42-48 12 0.105
51-60 10 0.134
63-66 8 0.164
69-72 3/16” 0.188
Table 1* U.S. standard gage** Nominal thickness
A 72-inch diameter cylinder pipe on Ameron’s spiral weld machine.
where:
As = total cross-sectional area of circumferential steel, in²/LF of pipe wall
Ay = cross-sectional area of circumferential steel in the cylinder, in²/LF of pipe wall
Ab = cross-sectional area of circumferential steel in the bar reinforcement, in²/LF of pipe wall
S.F. = Safety Factor; 2.0
Pd = design pressure, psi
Dy = inside diameter of steel cylinder, in.
S = 36,000 psi
The actual yield strength of the steel used to manufacture the cylinders is typically greater than 36,000 psi, resulting in an actual Safety Factor greater than 2 to 1 in the equation.
The required circumferential steel area for a given diameter and pressure class of pipe can be provided by several combinations of steel cylinder thicknesses, and bar diameters and spacing. Any combination which satisfies the following criteria may be selected.
•Minimum steel cylinder gage thicknesses shall be as shown in Table 1.•Minimum yield strength of steel = 36,000 psi.•Minimum diameter of bar reinforcement shall be R in.•Minimum area of bar reinforcement shall be 0.23 square inches per
foot of pipe wall or numerically equal to 1 percent of the pipe diameter in inches.
•Maximum center-to-center spacing of bar reinforcement shall not exceed 2 inches.
•Design clear space between bars shall not be less than 1.5 times the diameter of the bar used.
= +
= 6 [ . .]
s y
y d
b
Pipe Design
The design of Concrete Cylinder Pipe conforms to AWWA Standard C303 and AWWA Manual M9.
Hydrostatic Design
The average circumferential stress in the steel cylinder and bar reinforcement of the pipe at design pressure is limited to 36,000 psi, the specified minimum yield strength of the steel used in the cylinder. The following procedure represents a minimum 2 to 1 safety factor.
Water Transmission Group Bar-Wrapped Concrete Cylinder Pipe (CCP)
External Load Design
CCP is a semi-rigid pipe designed as a composite wall steel and concrete structure. External loads of buried CCP pipelines are resisted by the ring flexural strength of the pipe (pipe stiffness) and by the passive lateral earth pressure on the sides of the pipe. The composite wall construction of CCP contributes significantly to its rigidity and, consequently, to its external load carrying capacity.
Recommended bedding and back filling procedures are included in Ameron’s Installation Guide for Semi-Rigid to Flexible Pipe and AWWA Manual M9. Ameron’s engineers can help determine your project’s specific pipe design based on pressure and earth cover load.
Standard Designs
Standard designs for Bar-Wrapped Concrete Cylinder Pipe based on a safety factor of 2.0 and a minimum yield of 36,000 psi for the steel are available on our website. The steel cylinder thicknesses and bar diameters may vary provided the total steel area, As, is equal to or greater than shown. The standard designs provide an allowance for transient pressure 1.5 times the design pressure in the pipe.
Specifications
Guide specifications for Bar-Wrapped Concrete Cylinder Pipe are available on our website.
A combination of graded backfill material and native soils are used to backfill CCP.
Ameron supplied this 72-inch diameter Bar-Wrapped Concrete Cylinder Pipe.
Pipe Dimensions
Tb
s
TC
D
L3.25"
NOM. LAP
t
Dj
Js
ROUND RUBBER GASKETBc Tl Dy
db
y
Bc = Outside diameter of pipe barrel, ftDb = Bar diameter, in.D = Inside diameter of pipe, in.Dy = Inside diameter of steel cylinder. in.Dj = Joint diameter, in.Js = Interior joint space
L = Standard laying length. fts = Bar spacing. center-to-center, in.tb = Bell thickness, in.tc = Minimum cement mortar coating thickness over steel bar, in. (0.75” minimum)tl = Nominal concrete or cement mortar fining thickness, in.ty = Cylinder thickness, in.
Pipe Inside Diameter
D
StandardLaying Length*
L
Outside Diameter Steel Cylinder
Dy + 2ty
Joint Diameter
Dj
Outside Diameter Pipe Barrel
Bc
Deflected Joint Beveled Joint Pipe Weight***
MinimumDeflection
MinimumRadius**
MaximumBevel
MinimumRadius**
t1 = 0.75”tc = 0.75”
inches feet inches inches feet degrees feet degrees feet lb/LF
18 36 19.78 20.28 1.82 2.11 978 5.00 412 140
20 40 21.78 22.28 1.98 1.92 1194 5.00 458 160
21 40 22.78 23.28 2.07 1.84 1246 5.00 458 165
24 45 25.75 26.25 2.31 2.18 1183 5.00 515 190
27 45 28.78 29.28 2.57 1.95 1323 5.00 515 215
30 45 31.875 32.375 2.82 1.76 1466 5.00 514 250
33 45 34.875 35.375 3.07 1.61 1602 5.00 514 280
36 45 37.875 38.375 3.32 1.49 1731 5.00 514 315
39 45 40.875 41.375 3.57 1.38 1869 5.00 514 340
42 45 43.875 44.375 3.82 1.29 2000 5.00 514 370
45 45 46.875 47.375 4.07 1.20 2150 5.00 514 400
48 45 49.875 50.375 4.33 1.13 2283 5.00 514 430
51 45 52.875 53.375 4.58 1.07 2411 5.00 514 470
54 45 55.875 56.375 4.83 1.01 2554 5.00 513 500
57 45 58.875 59.375 5.08 0.96 2687 5.00 513 540
60 45 61.875 62.375 5.33 0.92 2804 5.00 513 570
63 45 64.875 65.375 5.58 0.87 2965 5.00 513 610
66 45 67.875 68.375 5.85 0.84 3071 5.00 513 650
69 45 70.875 71.375 6.09 0.80 3224 5.00 513 690
72 45 73.875 74.375 6.37 0.77 3350 5.00 513 730
Table 2. Pipe Dimensions * Shorter lengths are available. ** Based on Standard Laying Lengths shown. Tighter radius can be achieved with shorter lengths. *** Pipe weight is for Class 150.
Applying mortar coating over bar-wrapped steel cylinder
Pipe dimensions
Centrifugally casting cement mortar lining inside steel cylinder
Water Transmission Group Bar-Wrapped Concrete Cylinder Pipe (CCP)
A full range of special pipe and fittings is available to satisfy project requirements. They are custom fabricated at the pipe manufacturing facility and delivered with the pipe to the construction site in proper sequence for installation in the pipeline. The design and manufacture of steel fitting and special pipe conform to the applicable section of AWWA Standard C303; their dimensions conform to AWWA Standard C208. Flanges for service rating to 300 psi conform to AWWA Standard C207. Flanges for service rating greater than 300 psi conform to ANSI Standard B16.5.
Virtually any size and shape can be supplied with various end configurations including rubber gasket, lap weld, buttstrap, flanged, mechanical couplings and plain ends.
Changes in Direction
Long-radius curves and minor changes in pipeline direction are achieved by joint deflection of standard pipe or by the use of pipe sections with ends beveled up to 5 degrees. For shorter radius curves, fabricated elbows are provided.
Special Pipe
Special pipe has the same design as standard pipe that is modified to incorporate short lengths, beveled ends and built-in outlets for manholes, air valves, blowoffs and other connections. The steel cylinder at the outlet opening is reinforced with either a steel collar, a wrapper plate or a crotch plate, depending on cylinder thickness, pipe and outlet diameters, and operating conditions.
Fittings
Fittings include elbows, reducers, and connections to mainline valves and appurtenances. These are fabricated from steel plate or sheet and cement mortar, lined and coated. The cylinder diameter for the mainline portion of the fitting is equal to the cylinder diameter of standard pipe.
Fitting Design
The design thickness of the steel cylinder used in a fitting is:
Double-Gasket Spigot Pipe
The reliability and durability of our standard, single, rubber-gasket joints have been proven for more than 70 years. However, in special applications, Ameron’s double gasket spigot pipe (see figure above) can be specified and used for the following:
•Field testing a field joint prior to laying the next pipe section•Field testing the pipe joints after the completion of the backfill• In areas where water is not readily available for field hydrostatic
testing•For subaqueous installations•For pipe installations in or near seismically active areas• In high-fill areas with the possibility of long-term settlement• In areas where the added protection of an additional gasket
is required
where:S.F. = Safety Factor; 2.0Pd = design pressure, psiDy = inside diameter of steel cylinder, in.S = 33,000 psiFittings are designed to be equal in strength to the adjacent standard pipe sections. The minimum steel cylinder thicknesses used in fittings are shown in Table 3.
= [ . .]
2 y y d
Fitting Diameter Range Minimum Thickness of Sheet or Plate
inches inches
18-21 0.135
24-36 0.179
39-48 0.2500
51-60 0.313
63-72 0.375
Table 3
CCP can be furnished with various end configurations to meet project requirements. A Carnegie joint with a single gasket is shown.
4.75"NOM LAP
A double gasket spigot pipe
Special Pipe and Fittings
© 2014 National Oilwell VarcoAll rights reserved
D392005308-MKT-001 Rev. 01
National Oilwell Varco has produced this brochure for general information only, and it is not intended for design purposes. Although every effort has been made to maintain the accuracy and reliability of its contents, National Oilwell Varco in no way assumes responsibility for liability for any loss, damage or injury resulting from the use of information and data herein. All applications for the material described are at the user’s risk and are the user’s responsibility.
w w w. n o v. c o m / A m e r o n
O n e C o m p a n y . . . U n l i m i t e d S o l u t i o n s
NOV Corporate Headquarters7909 Parkwood Circle DriveHouston, Texas 77036United StatesPhone: 713 375 3700Fax: 713 346 7687
Ameron International
HeadquartersWater Transmission Group10681 Foothill Boulevard, Suite 450Rancho Cucamonga, California 91730United StatesPhone: 909 944 4100Fax: 909 944 4113
Tracy Plant10100 W. Linne RoadTracy, California 95377United StatesPhone: 209 836 5050
Phoenix Plant2325 S. 7th StreetPhoenix, Arizona 85034United StatesPhone: 602 252 7111
SLRC PlantVia Ameron 100San Luis Rio Colorado, SonoraMexico
American Pipe and Construction International APCIApartado Aereo No. 90087Santa Fe de Bogota, ColombiaPhone: 57 1 6740600
Protective Linings Division201 North Berry StreetBrea, California 92821United StatesPhone: 714 256 1124
Downhole Solutions
Drilling Solutions
Engineering and Project Management Solutions
Industrial Solutions
Lifting and Handling Solutions
Production Solutions
Supply Chain Solutions
Tubular and Corrosion Control Solutions
Well Service and Completion Solutions