Top Banner
Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th December 2007 December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk 6b Park St Leamington Spa CV32 4QN UK
22

Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Jan 31, 2018

Download

Documents

haminh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Warwick Wind Trial Results to Date

David Hailes and Helen Brown

11th

December 2007

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 2: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Agenda

Objectives of the trial•

Overview of the sites

Instrumentation and Analysis•

How useful is NOABL and MCS

How useful are power curves•

Patterns between sites

Energy consumption•

Conclusions

Page 3: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Objectives

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

To explore the market realities facing this technology

To understand community and customer reactions

To see how predictable technical performance is for customers

Typical customer starting points:

NOABL

No wind monitoring

Basic property geometry

Aim to complement and inform academic and industry trials

Page 4: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Instrumentation

PEET Kit

Meteo

Anemometer

Novus

Logbox

DA

ME162 Watt meter

BRE Kit

NRG Anemometer

Pace Scientific XR5-SE

ME162 Watt meter

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 5: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Sites

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 6: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

What could you expect to generate?

Average Energy Generated per Day (Wh)

63

63

67

91

174

187

211

225

251

253

385

394

875

875

1790

0 200 400 600 800 1000 1200 1400 1600 1800 2000

22nd August 2007

April (2007)

October (2005)

3rd July 2007

29th January 2007

30th January 2007

20th March 2007

7th October 2007

7th October 2007

7th October 2007

7th October 2007

1st November2007

7th October 2007

7th October 2007

24th September 2007

Inst

alle

d da

te

Average energy generated per day (Wh)

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 7: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

How useful is NOABL and the Microgeneration Installation Standard MIS3003?

Very early days•

NOABL data corrected for the month using a 20 year average taken from International Station Meteorological Climate Summary, Version 4.0

Above correction corrected again using MIS3003

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 8: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Measured Wind Speeds For a suburban location

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 9: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Measured Wind Speeds vs

Corrected

NOABL by month For a suburban location

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 10: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Measured Wind Speeds vs

MIS3003

Corrections For a suburban location

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 11: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Difficult to categorise in MCS

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 12: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Measured Wind Speeds vs

Corrected

NOABL by month For a Dense Urban location

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 13: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Measured Wind Speeds vs

MIS3003

Corrections For a Dense Urban location

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 14: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

How useful are Power Curves

All power curves are supplied by manufacturer or installer literature.

Can they be used to predict output?

Are there variations between manufacturers?

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 15: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Energy Calculations Using Power Curve

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 16: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Energy Calculations Using Power Curve

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 17: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Energy Calculations Using Power Curve

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 18: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Wind Speed Distribution

Can we spot any patterns?

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 19: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Can we spot any patterns? Suburban

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 20: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Can we spot any patterns? High Rise

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 21: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

How much energy do they consume?

Imported energy as proportion of exported energy

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.25

0.34

0.38

0.89

1.27

1.50

4.33

0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00

3rd July 2007

7th October 2007

7th October 2007

7th October 2007

7th October 2007

7th October 2007

24th September 2007

7th October 2007

22nd August 2007

October (2006)

30th January 2007

29th January 2007

April (2007)

20th March 2007

October (2005)

1st November2007

Inst

alle

d da

te

Ratio

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK

Page 22: Warwick Wind Trial - urbanwind Wind Trial Results.pdf · Warwick Wind Trial Results to Date David Hailes and Helen Brown 11 th. December 2007. ... 875 1790 0 200 400 600 800 1000

Conclusions

MIS3003 offers a helpful insight on low sites

Quality of power curves vary by manufacturer

There are patterns emerging

More data required to build up a more complete picture

Contact David Hailes [email protected]

December 2007 Warwick Wind Trial 01926 312159 www.encraft.co.uk

6b Park St Leamington

Spa CV32 4QN UK