Jergel's Rhythm Grille WARRENDALE, PA Entertainment Audio Video Technical Specifications
9

WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

Jan 26, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

Jergel's Rhythm GrilleW A R R E N D A L E , P A

Entertainment ★ Audio ★ Video ★ Technical Specifications

Page 2: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

Jergel's is a 17,000 square foot facility packed with pro-sound audio and the best in video capabilities. Featuring 23 high-definition television monitors and two 14-foot projection monitors, you won’t miss a beat when you’re in our house!

Highlights of the Venue: • Centrally located on 3.5 acres with 190 parking spaces, within ½ mile of Interstate I-79 and the PA Turnpike

• Capacity of 600+

• 32 ft. stage for all live performances

• Permanently installed state-of-the-art Pro Sound and lighting

• Private dressing room w/full bath for show performers

• Second floor balcony with full views of the stage below

• Full restaurant (120 seats)

• Cigar/Scotch bar (featuring 30 scotches)

• Three large bar areas with 18 draft beers

• Outdoor patio area with two fire pits

• 80-seat banquet facility and 18-seat VIP Lounge for private parties

• Four second floor VIP/custom private booths

• Shuttle services featuring Cranberry Taxi, Classy Cab and Star Limo service

• Free Wi-fi

A sampling of shows that have played at Jergel'salphabetical order

• ASIA

• Artemus Pyle

• Black Lillies

• BoDeans

• Bret Michaels

• Cadillac Three

• Canaan Smith

• Clarks

• Dave Mason

• Donnie Iris

• Eddie Money

• Fabulous Thunderbirds

• Foghat

• Geoff Tate

• Gin Blossoms

• Jefferson Starship

• Leon Russell

• Little Feat

• Little River Band

• Locash

• Lou Graham

• Marshall Tucker

• Michael Stanley

• Molly Hatchett

• Night Ranger

• Outlaws

• Parmalee

• Pure Prairie League

• Reb Beach

• Robert Randolph

• Sonny Landreth

• Southside Johnny

• Uriah Heep

• Shooter Jennings

• Smithereens

• Tubes

• WAR

- 1 -

Page 3: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

TECHNICAL SPECS Stage Dimension: • 32 Feet wide X 19 Feet Deep X 21 Inches High

Audio: • (1) Yamaha LS932 Digital Console-FOH

• (2) Martin Audio W8VDQ (Three-Way Passive/Biamp) Flown Second Floor. (1 left/1 right)

• (2) Martin Audio WS218X Dual 18” Subs. Built into stage. Stage Left/ Stage Right

• (2) Martin Audio W8VDQ (Three-Way Passive/Biamp) Flown First Floor. Stage Left/Stage Right

• BSS Mini Drive

• (3) QSC ISA1350 Amps (1300w @ 4ohm; 1300 @ 4ohm)

• (6) QSC KW 122, 12”x2” Powered Active Monitors

• (1) QSC KW 181 Sub-Woofer (Drum Mix)

• (4) EV 1/3 Octave EQ- Stage Monitors

• (1) Rapco 48 Channel Mic Splitter, 100’ fan to FOH, 25’ fan for Monitor Console (Transformer Balanced with Ground Lifts)

Microphones/Misc Gear: • (4) Audix i5 Instrument Microphone

• (6) Shure SM58LC Handheld Microphone

• (2) K&M 2591 Heavy Base Short Stand-Kick Drum

• (6) K&M 259 Short Tripod Stand

• (6) K&M 2109 Tripod Boom Stand

• (6) K&M #252 3 Section Tripod Boom Stand

• (25) Belden Ultimate 25’ Mic Cable w/ Neutrik Conn.

• (10) Belden Ultimate 10’ Mic Cable w/ Neutrik Conn.

Stage Equipment/Drum Mics: • (2) Radial Engineering Stage Slug (12x25’)

• (5) Radial Engineering ProD1 Direct Box

• (2) Radial Engineering ProD2 Direct Box

• (1) Heil PR48 Kick Drum Microphone

• (2) Audix D2

• (2) Audix D4

• (4) MicEze M3 Drum Clip

• (3) AT 4041 Condensor Microphone

Stage/Floor Lighting: • (1) Leprecon 36 Channel Controller-Stage

• (1) S/MC-7016 NSI Controller-Dance Floor

• (18) 36HP 1W RGB LED

• (6) 24-1 Watt, Elation LED

• (10) Applied LD 12x12 Box Truss

• (3) Tomcat 12x12 Core Truss

• (6) ETC JR Zoom

• (3) ETC S4 19 Degree

• (2) 6 Ch Dimmer Hp-Duplex

• (1) 5 Way OPTO ISO Splitter

• (12) Elation Micro Wash RGBW

• (5) Opti LED

• (1) Mystic Multi Light

• (1) Avenger II Multi Light

• (1) Follow Spot-On Tripod

- 2 -

Page 4: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

32 ft. stage right to stage left

16 ft. downstage center to upstage center

Second floor railing aligns with back side of stage

Subs: 50 in. wide by 25 in. deep,9 in. above stage level

21 in.

30 in.

48 in.from steel

beam to wall

48 in.from steel

beam to wall

30 in.

32 ft.

21 ft. between steel beams

33 ft.

19.9 ft.

- 3 -

Page 5: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

REGULAR STAGE DIMENSIONS

32 ft.

16 ft.

19.9 ft.

9 in. beam 9 in. beam

17.9 ft.50 in. 50 in.45° 45°

- 4 -

Page 6: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

OPTIONAL STAGE DIMENSIONS

32 ft.

16 ft.

19.9 ft.

9 in. beam 9 in. beam

17.9 ft.50 in. 50 in.

16 ft.

45° 45°

4 ft.

23.9 ft.

- 5 -

Page 7: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

first floor planSCALE - 1/4" = 1'

STAGE:32 Feet wide X 16 Feet Deep X 21 Inches High SOUND BOOTH

- 6 -

Page 8: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

MEZZANINE floor planSCALE - 1/4" = 1'

DRESSING ROOM

STAGE VIEW FROM SECOND FLOOR

- 7 -

Page 9: WARRENDALE, PAjergels.com/wp-content/uploads/2017/01/1.25.16_Jergels_Technical_Specs.pdf · • Uriah Heep • Shooter Jennings • Smithereens • Tubes • WAR - 1 -TECHNICAL SPECS

EXTERIOR SEATING floor planSCALE - 1/4" = 1'

- 8 -