CONTACT US at 1-888-5-WARMUPWARMUP INC. 4 Robert Speck Parkway, Suite 1500Mississauga, Ontario L4Z 1S1
The Warmup loose wire system is suitable for tile, carpet, vinyl, wood, stone and ceramic tile floors. With our plastic fixing guides, loose cables are quick and easy to install in irregular shaped rooms.
Features• Tough and thin wire: 1/8” (3 mm), multi-strand core,
double insulated using advanced fluoropolymers
• Approved for wet location applications
• Quick installation - Single connection lead for fewer steps - No need to return the wire to complete the circuit
• Easy installation with ultra thin plastic fixing strips (included)
Specifications• Operating voltage: 120V and 240V
• Wire thickness: 1/8” (3mm)
• Average output rating: 14 W/sq ft (at 3” spacing)
• Maximum operating temperature: 131°F/55°C
• Inner/outer insulation: Advanced fluoropolymers
• Cold tail length: 10 ft (3m)
• Cable heat output: 3.4 watts/linear foot
Earth braid
Multi-strand twin conductors
Advanced fluoropolymer insulation
INSTALLATIONGUARANTEE
TM
INSTALLATIONGUARANTEE
TM
Item
14W 11W
Length (ft)
Wattage (W)
Amps (A)
Resistance (Ω)
cable spaced at
3” 4”
gives sq ft coverage of
120
Volt
s
NADWS-120-140 10 13 40 140 1.2 102.9
NADWS-120-210 15 20 60 210 1.8 68.6
NADWS-120-280 20 27 80 280 2.3 51.4
NADWS-120-350 25 33 100 350 2.9 41.1
NADWS-120-420 30 40 120 420 3.5 34.3
NADWS-120-560 40 53 160 560 4.7 25.7
NADWS-120-700 50 67 200 700 5.8 20.6
NADWS-120-840 60 80 240 840 7.0 17.1
NADWS-120-1050 75 100 300 1050 8.8 13.7
NADWS-120-1260 90 120 360 1260 10.5 11.4
NADWS-120-1540 110 147 440 1540 12.8 9.4
NADWS-120-1620 120 160 480 1620 13.5 8.9
240
Volt
s
NADWS-240-350 25 33 100 350 1.5 164.6
NADWS-240-560 40 53 160 560 2.3 102.9
NADWS-240-700 50 67 200 700 2.9 82.3
NADWS-240-1050 75 100 300 1050 4.4 54.9
NADWS-240-1260 90 120 360 1260 5.3 45.7
NADWS-240-1540 110 147 440 1540 6.4 37.4
NADWS-240-2100 150 200 600 2100 8.8 27.4
NADWS-240-2520 180 240 720 2520 10.5 22.9
NADWS-240-3080 220 293 880 3080 12.8 18.7
NADWS-240-3240 240 320 960 3240 13.5 17.8
Sizing guide
CONTACT US at 1-888-5-WARMUPWARMUP INC. 4 Robert Speck Parkway, Suite 1500Mississauga, Ontario L4Z 1S1
The Warmup mat heating system is ideal for tile, carpet, vinyl, wood, stone and ceramic tile floors. The system is made up of advanced fluoropolymer insulated heating strands that are pre-spaced on to a thin fibreglass mesh to give an even and consistent heat output. This sytsem is ideal for larger regular shaped rooms.
Features• Sturdy fibreglass mesh for extra durability and super-
sticky double-sided tape for secure installation
• Even distribution of heat with even wire spacing
• Quick installation - Simply roll out mat with pre-spaced wire
• Suitable for wet locations and showers
• Flexible - can be cut around fixings
Specifications• Operating voltage 120V and 240V; 50/60Hz
• Width: 20” (500 mm)
• Overall mat thickness: 1/8” (3 mm)
• Inner and outer insulation: Advanced fluoropolymers
The cut & turn foil panel by Warmup is an ultra thin electric radiant floor heating system designed for use under carpet, laminate, cork, engineered wood and other floating floors.
It can be conveniently installed under the floor finish in both dry and wet areas without the need for additional earth grids.
Features• Installs between the insulation pad and the final floor
Warmup in-slab heating cable is excellent for installations within a concrete slab of any size. Once installed, the heated slab can be covered with any flooring type, including hardwood, vinyl, flagstones and more.
The in slab system is ideal for primary heating in conjunction with a suitable thermal block below the cable. The programmable thermostat can be set to utilize off-peak electricity making this application a perfect energy efficient thermal storage system.
Features• Tough thick heating cable is
protected by multiple layers of metal sheathing and insulation
• Floor covering can be changed without risk of damage to the heating cable
• Versatile - compatible with all floor finishes
• Suitable for new builds
Specifications• Operating voltage: 120V, 240V and 208V (de-rated)
• Cable thickness: 3/8” (10 mm)
• Cable heat output: 5.5W/linear foot
• Maximum operating temperature: 464°F (240°C)
• Cold lead length: 16.4” (610cm)
• Cable length tolerance: +/-5%
Sizing guide
In-slab heating cable system
Earth braid
Core
Advanced fluoropolymers insulation
Sheath
Return braid
Wire color may vary
• Spaced at 3”, 4” or 5” for in-slab heating with output of 21W, 17W and 12W per square foot
• Available in a wide range of lengths to suit your requirements
Designed exclusively by Warmup, the 3iE™ is the world’s first fully interactive, touch technology, energy monitoring thermostat, with a color screen and integrated GFCI.
The Warmup 3iE™ allows you to view actual graphs of your recorded energy consumption against costs. That means you know exactly what your underfloor heating running costs are.
Features• Easy-to-use interface
• Clear graphical display makes any adjustment quick and easy
• Choose the display style that suits you best – wide choice of screen themes
• Automatically adjusts to changing conditions to give optimal start-up times
• Graphics-based energy monitor shows exactly how much energy is being used and when
The Warmup Floor heating programmable thermostat WUDG is a digital thermostat with four (4) easy-to-program on/off settings per day.
Choose from three (3) sensor settings: ambient (built-in sensor), floor probe or ambient and floor. The master thermostat can be combined with one or more relays to heat large areas.
Features• Stylish and simple user interface
• Pre-programmed for quick set-up
• Monitored energy consumption
• Multi voltage: 120-240V (incl. 208V)
• Class A GFCI for wet room installation
• WUSG Relay available for applications greater than 15 A
Specifications• Supply: 120-240 Vac, 50/60 Hz
• Load: 15A maximum (resistive load)
• Power: 1800W @ 120V and 3600W @ 240V
• GFCI: Class A (5 mA trip level)
• Temperature range: +41°F to +104°F (+5°C to 40°C)
• Housing: Nema 2 (IP21)
• Floor sensor type: NTC (12 KΩ) 9 ft (2.7m)
• Dimensions(H/W/D): 4.8”x3.0”x1.0” Products and accessories
Floor heating thermostats
Code Description Amps (A)
3iE3iE™ Energy-Monitoring Thermostat with built-in GFCI - 120/240V Available in black, white, cream, silver, blue, pink, green and plum
Max 15 amp.
BACKBOX3iE 4” square electrical back box with single gang mud ring n/a
WUDG-4999 Dual voltage thermostat Max 15 amp.
WUSG-4999 Relay to combine with WUDG-4999 for large areas Max 15 amp.
WUDG-SENSOR Floor sensor probe for WUDG-4999 thermostat n/a
3IE-SENSOR Floor sensor probe for 3iE thermostat n/a
CFS12 Pack of 50 plastic cable fixing strips n/a
CONTACT US at 1-888-5-WARMUPWARMUP INC. 4 Robert Speck Parkway, Suite 1500Mississauga, Ontario L4Z 1S1
Warmup insulation boards (WIB) are made of waterproof extruded polystyrene with a fiberglass mesh embedded on each face into a cement polymer adhesive.
Warmup insulation boards (WIB) are approved for installation over all subfloor types and are suitable to provide insulation under most flooring material.
Easy to cut with a knife, it installs to any surface and with its excellent load-bearing it is ideal for thinset and tiles. Free of harmful asbestos, this board poses no health or safety risks and is unaffected by the freeze/thaw cycle.
Specifications• Meets ANSI, UBC and ASTM standards
• Compressive strength [ASTM D1621]: 36 psi or 0.40 N/mm2
Roof, gutter and pipe deicingSelf-regulating cable
Warmup self-regulating cables are ideal for keeping roofs, gutters and pipes snow and ice free in all commercial and residential applications.
The nature of the self-regulating cable causes its output of 3, 5 or 8 W/linear foot to vary with the outside conditions, thereby guaranteeing the safeguard of ducts and pipes.
Features• Available in 3, 5 and 8 watts per linear foot
• For use on metal and plastic pipes
• Available in pre-terminated kits (NAMSRK) or stock spools of 500ft (NAMSR)
• Easy to install, the self-regulating cable can be cut to any length in the field.
• Energy efficient, the self-regulating cable uses less energy when less heat is required.
Specifications• Voltages: 120, 208-277V
• Maximum maintenance temperature: 100°F/38°C
• Maximum exposure temperature: 185°F/85°C (power off)
• Approximate size: 3/8”W x 1/8”H
• Industrial Grade: 16 AWG Buss Wire
• Minimum Bend Radius 1-1/8”
• Circuit Lengths: up to 660 Ft.
Self-regulating cables
Length (ft) Cables Wattage (W/lin ft) @50°F
120
Volt
s 500 NAMSR-3W-120V 3
500 NAMSR-5W-120V 5
500 NAMSR8W-120V 8
240
Volt
s 500 NAMSR-3W-240V 3
500 NAMSR-5W-240V 5
500 NAMSR-8W-240V 8
120
Volt
s K
its
6 NAMSRK-6FT 5
12 NAMSRK-12FT 5
18 NAMSRK-18FT 5
24 NAMSRK-24FT 5
50 NAMSRK-50FT 5
Kits are sold with 3ft attached 3-prong molded plugs. Clips are not included.
For a list of the accessories needed for roof & gutter / pipe freeze protection applications, please refer to the Accessories spec sheet
CONTACT US at 1-888-5-WARMUPWARMUP INC. 4 Robert Speck Parkway, Suite 1500Mississauga, Ontario L4Z 1S1
The Warmup all-in-one sensor/controller (USASE - DS2/5) has a built-in sensor (external sensor for DS8) to automatically activate the snowmelt heating system. It is ideal for projects like stairs, walkways and driveways.
Features• Sensors & controller in one outdoor unit (except DS8)
The Warmup snowmelt advanced thermostat (USET02) is used for multiple-zone projects such as a combined roof and ground application. The system automatically activates via readings from temperature and moisture sensors.
Features• 2 zone control in one unit. Can control roof, ground
or roof & ground zones
• Can be switched to standby or forced on to override timer settings in extreme weather conditions
• Indoor mounting
• Electronic on/off control up to 11 kW
• Detection of temperature and moisture
• can be used to control external contactors for larger applications
The Warmup line voltage thermostats are perfect for small and medium sized projects. The devices come with a 5 ft remote capillary sensor (TRF115-005) or a control-mounted sensor (TF115) which activates heating cables on roof & gutter applications or in pipe freeze protection applications.
Features• NEMA 4R rugged, weather resistant enclosure
• Low mass, high surface area of sensors provide rapid response to temperature change
• Multi-positional mounting offers flexibility in new or existing installations