Top Banner
S.Hild and A.Freise January 2009 Warming up for the OSD workshop
9

Warming up for the OSD workshop

Jan 14, 2016

Download

Documents

Patty

Warming up for the OSD workshop. S.Hild and A.Freise January 2009. Reference layout of NDRC. See talk by Massimo. QUESTION => How much astigmatism is introduced by: Divergent beam (strong lens in input mirrors) passing BS and CP? Off axis telescopes of PRM1-3 and SRM1-3? - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Warming up for the OSD workshop

S.Hild and A.Freise

January 2009

Warming up for the OSD workshop

Page 2: Warming up for the OSD workshop

S. Hild January 2009 Slide 2

Reference layout of NDRC

QUESTION => How much astigmatism is introduced by: Divergent beam (strong lens

in input mirrors) passing BS and CP?

Off axis telescopes of PRM1-3 and SRM1-3?

QUESTION => How much astigmatism driven loss we can accept in PRC and SRC?

QUESTION => How to suspend PRM1, PRM3, SRM1 and SRM3?

See talk by Matteo

See talk by Massimo

Page 3: Warming up for the OSD workshop

S. Hild January 2009 Slide 3

NDRC with lenses moved to the BS In case the astigmatism

from the BS and the CPs is too strong…

IDEA: Move lenses out of input mirrors and put them close to the BS (out of IFO arms).

QUESTION => How to suspend the lenses in the BS tank?

QUESTION => Can we buy such lenses (quality, size, …)

QUESTION => Does the Non-Degeneracy still work in this setup?

See talk by Roberto/ Giovanni

Page 4: Warming up for the OSD workshop

S. Hild January 2009 Slide 4

Long NDRC without lenses In case we want/need a design without

any lenses we have to make the recycling cavities as long as possible…

IDEA (from Julien): Move PRM2 into north input tank, passing the beam underneath BS and suspend PRM2 from IM reference mass.

QUESTION => Does non-degeneracy still work?

QUESTION => Is it possible to suspende PRM2 from the reference mass?

QUESTION => Can we fit beams into the vacuum?

QUESTION => Could we fit suspended 35 cm optics onto the injection and detection benches?

See talk by Carlo/Antonio

See talks by Benoit and Eric ?

See slides from Andreas

See talk by Julien

Page 5: Warming up for the OSD workshop

S. Hild January 2009 Slide 5

Pick-off beams

QUESTION => Which pick-off beams are necessary for ISC? BSAR? IM/CP?

Proposed Strategy: all secondary beams (4 beams from each CP, 2 beams from each IM, 3 beams from BS = TOTAL about 15 large beams) are either detected or properly dumped.

Page 6: Warming up for the OSD workshop

S. Hild January 2009 Slide 6

Pick-off beams from IM and CP

QUESTION => Can pick-offs, consisting of several beams, be used for ISC purpose?

QUESTION => Is it possible to deal with divergent pick-off beams (up to about 1m diameter!)

QUESTION => Do we have the space direct pick-offs in 4 different directions (below, above, left and right of main beam)?This plot is only to show effects qualitatively. A proper CAD drawing is required…

Page 7: Warming up for the OSD workshop

S. Hild January 2009 Slide 7

Eliminating pick-offs from IM and CP?

We could get rid of the pick-off beams from the IM-AR by making them etalons: QUESTION: Are the etalons required for reducing noise couplings? QUESTION: Would it be possible to control an IM etalon?

In principle we could get rid of CP secondary beams by aligning the CPs to the main beam: QUESTION: Any noise problems from additional low finesse Fabry Perot? QUESTION: Is it possible to keep the CPs aligned (refernce mass moves when

actuating on main test masses)?

Page 8: Warming up for the OSD workshop

S. Hild January 2009 Slide 8

Extraction of pick-off from BS-AR Pick-off from BS-AR coating needs to

separated from the main beam before being reflected back into the interferometer from the Signal-Recycling mirror.

IDEA: Extract the BSAR-pickoff close to the beam waist between SRM2 and SRM3 (should work even without BS wedge).

QUESTION => Is it possible install a beam director between SR tower and detection tower?

QUESTION => How to dump the other secondary beams of the BS-AR?

Page 9: Warming up for the OSD workshop

S. Hild January 2009 Slide 9