Top Banner
WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management Laverne Dalgleish Building Enclosure Moisture Management Institute (BEMMI)
34

WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Feb 25, 2016

Download

Documents

yuki_o

WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management. Laverne Dalgleish Building Enclosure Moisture Management Institute (BEMMI). Today’s Agenda. BEMMI Background Exterior Wall Science: As I Live and Breathe! Traditional Rainscreen Design - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Laverne DalgleishBuilding Enclosure Moisture Management

Institute (BEMMI)

Page 2: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Today’s Agenda

• BEMMI Background• Exterior Wall Science: As I Live and Breathe!• Traditional Rainscreen Design• Engineered Rainscreen Design• Absorptive Cladding• Building Code Requirements and Compliance• Bibliography

Page 3: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Building Enclosure Moisture Management Institute

• Founded in 2009• Founding Members:– Advanced Building Products– Benjamin Obdyke– Cosella-Dörken– CavClear/Archovations

Page 4: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

BEMMI Mission

To promote the growth of the engineered rainscreen products industry to improve moisture management in building enclosures through technical advocacy

Page 5: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Exterior Wall Science: As I Live and Breathe!

• Exterior Wall Assembly– Wall Covering Assembly– Water-Resistive Barrier– Insulating Sheathing (continuous insulation)– Structural Framing, Sheathing, Cavity Insulation– Interior Finish Materials

• Air Barrier Requirements• Penetrations

Page 6: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management
Page 7: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management
Page 8: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Traditional Rainscreen Design

• Ventilated Cladding– Anchored Brick and Stone Veneers– Wood Shakes and Shingles– Clapboards

• Drainage and Drying

Page 9: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Traditional Rainscreen Design

Page 10: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Absorptive Cladding

• Masonry and Stucco• Adhered Veneers• Wood Siding Materials• Engineered-wood Siding Materials• Cement-based Siding Materials

Page 11: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Absorptive Claddings

Page 12: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Engineered Rainscreen Design

• Bulk Water Drainage• Ventilation – – Precipitation, Condensation– Evaporation, Respiration

• Capillary Break Space – Isolate Cladding

Page 13: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Engineered Rainscreen Design

Types of Rainscreen Materials• 3-dimensional membrane • 3-dimensional mesh style• Polymer-based products• Roll out similar to water-resistive barriers• Continuous airspace

Page 14: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Engineered Rainscreen Design

Page 15: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

0.25 in (6mm) 0.40 in (10mm)Meets Canadian

Building Code

Engineered Rainscreen Design

Page 16: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Engineered Rainscreen Design

Page 17: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Engineered Rainscreen Design

Page 18: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Code Requirements: 2012 IRCSECTION R703

EXTERIOR COVERINGR703.1 General. Exterior walls shall provide the building with a weather-resistant exterior wall envelope. The exterior wall envelope shall include flashing as described in Section R703.8.R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water within the wall assembly by providing a water-resistant barrier behind the exterior veneer as required by Section R703.2 and a means of draining to the exterior water that enters the assembly. Protection against condensation in the exterior wall assembly shall be provided in accordance with Section R702.7 of this code.

Page 19: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Code Requirements: 2012 IRC

Exceptions:1. A weather-resistant exterior wall envelope shall not be required over concrete or masonry walls designed in accordance with Chapter 6 and flashed according to Section R703.7 or R703.8.

Page 20: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Code Requirements: 2012 IRCExceptions (cont.):2. Compliance with the requirements for a means of drainage, and the requirements of Sections R703.2 and R703.8, shall not be required for an exterior wall envelope that has been demonstrated to resist wind-driven rain through testing of the exterior wall envelope, including joints, penetrations and intersections with dissimilar materials, in accordance with ASTM E 331 under the following conditions:

Page 21: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Code Requirements: 2012 IRC

2.1. Exterior wall envelope test assemblies shall include at least one opening, one control joint, one wall/eave interface and one wall sill. All tested openings and penetrations shall be representative of the intended end-use configuration.2.2. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet (1219 mm by 2438 mm) in size.

Page 22: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Code Requirements: 2012 IRC

2.3 Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24 pounds per square foot (299 Pa).2.4. Exterior wall envelope assemblies shall be subjected to the minimum test exposure for a minimum of 2 hours.

Page 23: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Code Requirements: 2012 IRCPass / Fail Criteria

Exception 2 (cont.):The exterior wall envelope design shall be considered to resist wind-driven rain where the results of testing indicate that water did not penetrate control joints in the exterior wall envelope, joints at the perimeter of openings penetration or intersections of terminations with dissimilar materials.

Page 24: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

ASTM E331

Water penetration test.Simulates 8” rain / hr. with 50 mph wind.

Page 25: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Code Requirements: 2012 IRC

• IRC Provides Basic Performance Measures– Minimum Code (minimum legal requirements)

• Beyond Code:– Durability– Drainage and Drying– Moisture Management as Preventative Measure

Page 26: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Performance Expectations

• Help Remove Bulk Water• Promote Drying of Incidental and Absorbed

Water• Improve Condensation Management

Page 27: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

ICC-ES (Evaluation Services)

• Meeting the Intent of the Code– ICC-ES Acceptance Criteria: AC356• Drainage Test• Accelerated Aging & Weathering• Durability / Fungi Resistance• UV Exposure• Fire Resistance (optional)

Page 28: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Blower-Door Testing

Page 29: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Problem Areas

• Tighter the wall, the less it dries• Penetrations and openings create moisture

movement issues• Less expensive to address upfront than to fix

later

Page 30: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Engineered Rainscreen Performance• Drain bulk water from behind the cladding• Provide ventilation drying for other incidental

moisture• Separates cladding from WRB – Capillary break– Surfactant issues, enhance WRB durability

• Continuously over entire wall surface

Page 31: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Engineered Rainscreen Details

Rainscreen Material

Page 32: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Review

• BEMMI Background• Exterior Wall Science: As I Live and Breathe!• Traditional Rainscreen Design• Engineered Rainscreen Design• Absorptive Cladding• Building Code Requirements and Compliance• Bibliography

Page 33: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

Questions?

Page 34: WALL PERFORMANCE BY DESIGN: The Role of Rainscreens in Moisture Management

BibliographyAdvanced Building Products www.mortairvent.comAir Barrier Association of America www.airbarrier.org CavClear/Archovations www.cavclear.com Building Enclosure Moisture Management Institute www.bemmi.orgBenjamin Obdyke www.benjaminobdyke.comCosella-Dörken www.cosella-dorken.comInternational Code Council, Evaluation Services www.icc-es.orgInternational Code Council www.iccsafe.orgMasonry Veneer Manufacturers Association www.masonryveneer.org NAHB Research Center White Paper www.toolbase.org/PDF/DesignGuides/RainScreenDesigns.pdf