Asko Appliances, Inc PO BOX 940609 • Plano • Texas • 75094 www.askousa.com W6324W LINE SERIES TM CLASSIC Type: Front-load, Family-size washer, ADA Compliant Colors: White (W) PROGRAMS Sani, White, Color, Quick, PermaPress, Wool / Handwash OPTIONS Up to 1200 RPM speed, 3 Temperatures up to 140ºF, Super rinse (up to 7 rinses), High wash water level CAPACITY UltraCare TM family-size – 2.12 cu. ft. TECHNOLOGY Line Series TM Classic LCD display with SmoothDial TM technology, Internal water heater produces optimal temperatures during main wash, Automatic load balancing, Electronic automatic door latch, Thermistor electronic sensor ensures accurate wash temperatures within +/-1ºF, and Aqua Block System CONSTRUCTION New ActiveDrum TM , Quattro TM commercial design, SmartSeal TM door gasket, Stainless Steel inner/outer drum, Heavy duty life-tested motor, Galvanized steel base, Cast iron counter balance weights and rear flywheel . Noise level 54 dB(A)wash / 74 dB(A) spin ASKO Laundry Care W6324 W6324W & T744CW
4
Embed
W6324 - Creative Laundry SystemsVentless), W6324/T744C Condenser Dryer Any ASKO family-size dryer can be mounted on top of any matching ASKO washer. Stacking kits are
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Asko Appliances, Inc
PO BOX 940609 • Plano • Texas • 75094
www.askousa.com
W6324W LINE SERIES TM CLASSICType: Front-load, Family-size washer, ADA Compliant Colors: White (W)
OPTIONSUp to 1200 RPM speed, 3 Temperatures up to 140ºF, Super rinse (up to 7 rinses), High wash water level
CAPACITYUltraCareTM family-size – 2.12 cu. ft.
TECHNOLOGYLine SeriesTM Classic LCD display with SmoothDial TM
technology, Internal water heater produces optimal temperatures during main wash, Automatic load balancing, Electronic automatic door latch, Thermistor electronic sensor ensures accurate wash temperatures within +/-1ºF, and Aqua BlockSystem CONSTRUCTIONNew ActiveDrum
IMPORTANT:ONLyUSETHEWATERSUPPLyHOSEPROVIDED WITHTHISMACHINE.ASKOprovidesaqualityPEXwaterfillhosethatutilizesaUSstandard¾˝brassconnectionfittingforattachmentonthe watersupply/faucetsideandaMetricthreadedfittingforthewasher side connection.
Every ASKO washer is delivered ready-fitted with a plug and is intended for connection to an ASKO dryer, which is equipped with a matching receptacle. If the washer is used separately or with another dryer, it must be on a separate220V,20Ampsingle-phasecircuit.
Second-floor (above grade) installations must meet all local building codes.
When placing the washer next to a wall or cabinet, be sure to leave ¼˝ (6 mm) of space between the washer and the wall or cabinet.
23 7/8˝ (606 mm)1 ¾˝
(44 mm)
Power
cord
Inlet
valve
Drain
hose
6 ¼
˝(1
60 m
m)
4 ¾˝ (120 mm)
3 1/8˝(80 mm)
36˝ (914 mm)23 5/8˝
(597 mm)
33 ½
˝ – 3
4 ½
˝(8
50 –
876
mm
)
jpark
Typewritten Text
37
4 1/8˝(105 mm)
46 ¼˝(1175 mm)
23 7/8˝(606 mm)
23 ½˝(597 mm)
36˝(914 mm)
38 ½
˝ –
40 ½
˝ **
(978
mm
– 1
028
mm
)
With
6˝
Hid
denH
elpe
r™:
72 ¾
˝ –
74 ¾
˝(1
848
mm
– 1
898
mm
)66
¾˝
– 6
8 ¾
˝(1
695
mm
– 1
746
mm
)
Specifications are subject to change without notice. See installation instructions for additional details.
Any ASKO family-size dryer can be mounted on top of any matching ASKO washer. Stacking kits are provided with the ASKO family-size dryer.RefertotheASKO family-size dryer Use and Care Guide for stacking instructions.
Every ASKO family-size washer is delivered ready-fitted with a plug and is intended for connection to an ASKO family-size dryer which is equipped with a matching receptacle. When an ASKO family-size washer is connected to the ASKO family-sizedryer,use220V,30 Amp sin gle-phase circuit. When the ASKO family-size dryer is on a separateoutlet,use220V,20Ampsingle-phase circuit. If the washer is used separately or with another dryer,itmustbeonaseparate220V,20 Amp single-phase circuit.
When placing a stacked set next to a wall or cabinet, be sure to leave ¼˝ (6 mm) of space between the washer and the wall or cabinet.
NOTE : Condenser dryers require adequate ventilation for proper operation. A louvered door is recommended for closet installations.
ASKO condenser dryers must be installed to continuously drain through a hose attached to the rear of the machine. To ensure proper drainage, the drain must not be higher than 40˝ (1016 mm) above the bottom of the dryer.
See page 33 for venting requirements.
See page 34 for condensation drain requirements.
See page 38 for stacked cabinet or closet installation dimensions.
WARNING! Never stack a washer on top of a dryer!
WARNING! To reduce the risk of fire, vented dryers must be exhausted OUTDOORS or the equivalent.
Never cover the end of the dryer stub or vent hose with anything to catch lint,
*Includes control knob. ** Height with 6˝ (152 mm) HiddenHelper™ installed. The following 6˝ (152 mm) height
HiddenHelpers models are available – HI115, HDB115, HB115.
** No venting required for condenser dryer (T753C). When HiddenHelper™ is specified, see pages 42-43. The following 6˝ (152 mm) height HiddenHelpers models are available HI115, HDB115, HB115.
39Specifications are subject to change without notice. See installation instructions for additional details.
PLanning & Design: FAMILy-SIZELAUNDRy
STACKEDCABINETORCLOSETINSTALLATIONS
ASKO´s front controls make it possible to install the washers and dryers under a cabinet or in a closet. Make sure there is a ¼˝ (6 mm) minimum clearance between units and cabinet or wall. To ensure proper ventilation, we recommend louvered doors, particularly for condenser dryers.
Every ASKO family-size washer is delivered ready-fitted with a plug and is intended for connection to an ASKO family-size dryer which is equipped with a matching receptacle. When an ASKO family-size washer is connected to the ASKO family-size dryer, use220V,30Ampsingle-phasecircuit.WhentheASKO family-sizedryerisonaseparateoutlet,use220V,20Amp single-phase circuit. If the ASKO family-size washer is used separately or with another dryer, it must be on a separate 220V,20Ampsingle-phasecircuit.
vented Dryer OpeningT794FI, T784 and T754 family-size dryers can be vented from the rear, left or right side. The cabinet cutout illustrated below gives the dimensions for a rear exhaust.
See page 33 for venting requirements.
Condenser Dryer OpeningASKO condenser dryers must be installed to continuously drain through a hose attached to the rear of the machine.
To ensure proper drainage, the drain must not be higher than 40˝ (1016 mm) above the bottom of the dryer.
See page 34 for condensation drain requirements.
NOTE: To avoid crimping the electrical and water con nec tions, do not install the hookups between the area of 26˝ (660 mm) to 35˝ (889 mm) from the floor (as indicated by shaded area in illustrations above).
For stacked installations, we recommend a 6' (1829 mm) cord.
Never cover the end of the dryer stub or vent hose with anything to catch lint, except for a UL-approved vent bucket.
When HiddenHelper™ is specified, see pages 46-47. The following 6˝ (152 mm) height HiddenHelpers models are available - HI115, HDB115, HB115.
WARNING! To reduce the risk of fire, vented dryers must be exhausted OUTDOORS or the equivalent.
NOTE: A louvered door is recommended for closet installations using an ASKO condenser dryer.
72 ¾
˝ –
74 ¾
˝(1
848
mm
– 1
898
mm
)w
ith 6
˝ H
idde
nHel
per™
72 ¾
˝ –
74 ¾
˝(1
848
mm
– 1
898
mm
)w
ith 6
˝ (1
52 m
m) H
idde
nHel
per™
\
67 ½
˝ –
69
½˝
(171
5mm
– 1
765
mm
)
67 ½
˝ –
69 ½
˝(1
715
mm
– 1
765
mm
)
220V 30 AmpSingle Phase
Outlet
See note
220V 30 AmpSingle Phase
Outlet
See noteCold Water
Drain
Cold Water
Drain
Height with 6 ̋(152 mm) HiddenHelper™:45 ¼˝ – 46 ¼˝
(1149 mm – 1174 mm)
4 1/8˝(105 mm)
24 ½˝ minimum(622 mm)
24 ½˝ minimum(622 mm)
15 ¾
˝ m
in(4
00 m
m)
15 ¾
˝ m
in(4
00 m
m)
39 ¼
˝ –
40 ¼
˝(9
97 m
m –
10
22m
m)
25˝
(635 m
m) 25˝
(635 m
m)
72 ¾
˝ –
74 ¾
˝(1
848
mm
– 1
898
mm
)w
ith 6
˝ H
idde
nHel
per™
72 ¾
˝ –
74 ¾
˝(1
848
mm
– 1
898
mm
)w
ith 6
˝ (1
52 m
m) H
idde
nHel
per™
\
67 ½
˝ –
69
½˝
(171
5mm
– 1
765
mm
)
67 ½
˝ –
69 ½
˝(1
715
mm
– 1
765
mm
)
220V 30 AmpSingle Phase
Outlet
See note
220V 30 AmpSingle Phase
Outlet
See noteCold Water
Drain
Cold Water
Drain
Height with 6 ̋(152 mm) HiddenHelper™:45 ¼˝ – 46 ¼˝