Top Banner
W-H 1000 SYSTEM Wall cladding Metal product
8

W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

Mar 15, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

W-H 1000 SYSTEMWall cladding

Metal product

Page 2: W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

APPLICATION AREA

Acoustic and architectural design elements for market segments such as office, education, transportation etc., can be used for column claddings and bulkheads.

BENEFITS

n Variety of customised design solutionsn Impressive visual appearance n Complete acoustic wall solutionn Large module sizes with upright and reclined panel optionsn Easily assembled and demountedn Can be used as a magnetic board in office and education

environments

MAINTENANCE AND ENVIRONMENT

They are washable, making them easy to clean. Armstrong´s dirt-repelling powder coating has proven itself to be an indestructible surface finish for many decades. The solvent-free production process also makes our wall claddings innocuous from an ecological and health-related viewpoint.

QUALITY AND SERVICE

Armstrong´s production facilities guarantee optimal capacity and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality management and a global network of subsidiaries and distribution partners ensure orders are delivered on time.

PROJECT: Learning Commons Building - Manchester University (UK) :::::::: ARCHITECT: Sheppard Robson PROJECT: University of Texas at San Antonio, Multidisciplinary Studies Building :::::::: ARCHITECT: Alvidrez Architecture Inc., San Antonio, TX

:::: 3

WALL CLADDING SYSTEM W-H 1000

Page 3: W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

SPECIFICATION

System Hook-on solution with rectangular panels

Square edged

With 5 mm black gasket and plastic spacer on one short

and one long side

Offset distance standard 60 +10/-15 mm

Acoustical Standard with black acoustic fleece

treatment (further inlays on request)

Dimension Type A Length 600 – 1300 mm / Width 275 – 1000 mm

Type B Length 1301 – 2500 mm / Width 275 – 1000 mm

Type C Length 2501 – 3000 mm / Width 275 – 1000 mm

Type D Length 600 – 3000 mm / Width 275 – 1000 mm

Edge detail all around 30 mm for standard panels

40 different types of panels available on request

Grid Horizontal direction

C-wall profile fixed with wall anchors to the wall

CHOICE OF PANEL TYPE

STANDARD PERFORATION PATTERNS

ACOUSTIC PERFORMANCE

Metal wall cladding products have been tested for their acoustic performance of sound absorption. All perforated products can be supplied with a varietyof factory fitted acoustic infill options. Please contactus for more information.

THERMAL CONDUCTIVITY

(λ) W/mK50.0 : Steel0.04 : Acoustic fleece

HUMIDITY EXPOSURE

Not greater than 70% RH @ 16˚-23˚C for long termexposure. Not greater than 95% RH for short termexposure during building site installation.

SERVICES INTEGRATION

Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment.

CLEANING

Dust should be removed from the painted surfaceby wiping with a clean soft cloth. More stubbornmarks should be removed with a mild householddetergent in warm water. Excessive use of watershould be avoided. The use of abrasive cleaners orscrubbing of the painted surface is notrecommended.

COLOUR

Standard colourRAL 9010 white (20% gloss), optional Global White (12% gloss)

Special coloursOther RAL and NCS colours available on request

QUALITY STANDARD

Armstrong is a certified EN ISO 9001:2008 Quality Assumed Manufacturer. All wall cladding and grid items are manufactured to tolerances and quality standards as Armstrog ceilings. Where differences exists between this and any expressed or implied architectural specificaitons or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise.

ENVIRONMENTAL

Our metal panels have an average of up to 30% recycling content.Our European manufacturing plants are certified to:EN ISO 9001:2008ISO 14001:2004 + Cor. 1:2009.

Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings).

Microperforation Rd 1522Hole diameter: 1.5 mm Open area: 22%

Standard PerforationRg 2516Hole diameter: 2.5 mm Open area: 16%

RAL 9010 Global White RAL 9006 RAL 9007

executiontype

D01 - D10

executiontype

B01 - B10

executiontype

A01 - A10

executiontype

C01 - C10

panel alignment

panel dimensionpanel dimension

upright reclined

- 2500 mm

type A type B

- 1300 mm

type C type D

- 3000 mm

on request

specialsizes

- 3000 mm

on request

specialsizes

:::: 5

Page 4: W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

6 ::::

PROJECT: Learning Commons Building - Manchester University (UK) :::::::: ARCHITECT: Sheppard Robson

standard execution one single line upright

one single line reclined one single panel

standard execution one single line upright

one single line reclined one single panel

standard execution one single line upright

one single line reclined one single panel

Panels type A01 - A10length A: min. 600 / max. 1300 mmwidth B: min. 275 / max. 1000 mm

Panels type B01 - B10length A: min. 1301 / max. 2500 mmwidth B: min. 275 / max. 1000 mm

Panels type C01 - C10length A: min. 2501 / max. 3000 mmwidth B: min. 275 / max. 1000 mm

Panels type D01 - D10length A: min. 600 / max. 3000 mmwidth B: min. 275 / max. 1000 mm

standard execution one single line upright

one single line reclined one single panel

OVERVIEW AND CONSTRUCTION

Page 5: W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

:::: 9

PROJECT: Dubai International Airport. Dubai (UAE) :::::::: ARCHITECT: Aéroport de Paris (ADPi), Paris, France

Detail A connector for C-wall profile

C-wall profile length = 3

‚000 mm

Detail B wall anchor-installation

Detail C wall anchor installed

Detail D direct installation to wall (optional)

Detail E supporting bracket

4 x self drilling screweco-drill 3.5 x 9.5 mm

wall anchor for C-wall profile

wall anchor forC-wall profile

C-wall profile

2 x supporting bracket forC-wall profile

Raw wall

Raw wall

Raw wall

standard panelW-H 1000

supporting bracket for C-wall profile

wall anchor forC-wall profile

C-wall profile

C-wall profile

C-wall profileItem No. Designation

BPM 311200 plastic dowel UX-10

BPM 311201 screw for plastic dowel UX-10

BPM 315620 C-wall profile

BPM 315629 connector for C-wall profile

BPM 315628 supporting bracket for C-wall profile

BPM 315621 wall anchor for C-wall profile

BPM 311191 self drilling screw eco-drill 3.5 x 9.5 mm

raw wall

C-wall profile connector for C-wall profile

8 x self drilling screweco-drill 3.5 x 9.5 mm

C-wall profile

gasket 5 mm blackalong and across

plastic dowel UX-10 and screw

plastic dowel UX-10 and screw

PERSPECTIVE VIEW

Page 6: W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

:::: 1110 ::::

Type C01length A: min. 2‘501 / max. 3‘000 mmwidth B: min. 275 / max. 1‘000 mm4 suspension points on each long sideof the panel, upright misplaced

Type B01length A: min. 1‘301 / max. 2‘500 mmwidth B: min. 275 / max. 1‘000 mm3 suspension points on each long sideof the panel, upright misplaced

Type D01length A: min. 600 / max. 3‘000 mmwidth B: min. 275 / max. 1‘000 mm2 suspension points on each short sideof the panel, reclined misplaced

WALL PANEL TYPES

Type A01length A: min. 600 / max. 1‘300 mmwidth B: min. 275 / max. 1‘000 mm2 suspension points on each long sideof the panel, upright misplaced

Page 7: W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

:::: 1312 ::::

Detail F connection to the ceiling Detail G visible connection to the top Detail H connection to the top with profile

C-wall profile

wall anchor forC-wall profile

end profile

C-wall profile

wall anchor forC-wall profile

C-wall profile

wall anchor forC-wall profile

Detail J connection to the floor Detail K visible connection to the bottom

Detail L connection to the bottom with angle

C-wall profile

wall anchor forC-wall profile

C-wall profile

wall anchor forC-wall profile

C-wall profile

wall anchor forC-wall profile

angle

Detail M connection to the door frame Detail N connection to lintel

Detail I connection to the windowsill

windowsill

C-wall profile

wall anchor forC-wall profile

C-wall profile

wall anchor forC-wall profile

C-wall profile

wall anchor forC-wall profile

doorframe

door leaf

lintel (metal plate)

Detail O lateral connection to the wall Detail P visible lateral connection

Detail Q lateral connection to the door frame Detail R inside corner with gap

Detail S outside corner with special panel

wall anchor for C-wall profile

C-wall profile

supporting bracket for C-wall profile

wall anchor forC-wall profile

C-wall profiledoor frame

door leaf

special panel

wall anchor for C-wall profile

C-wall profile

supporting bracketfor C-wall profile

wall anchor for C-wall profile

C-wall profile

supporting bracket for C-wall profile

wall anchor for C-wall profile

C-wall profile

supporting bracket for C-wall profile

VERTICAL HORIZONTAL

CONCLUSION DETAILS

Page 8: W-H 1000 SYSTEM Wall cladding - Ceilings from Armstrong · 2019-11-26 · and the remarkably flexible production of wall cladding. Efficiently-organised processes, continuous quality

14 ::::

PROJECT: Dubai International Airport. Dubai (UAE) :::::::: ARCHITECT: Aeroport de Paris (ADPi), Paris, France

Starting position

n installed wall claddingn each panel can be dismounted

separately without a tool, starting from the top

n panels should only be touched with clean gloves

Step 1

n the panel must be lifted up vertically at min. 10 mm

n keep attention to existing installations

Step 2

n the panel can be removedn store the panel carefully

PANEL DISMOUNTING