VS-400 & VS-800 Fogger Smoke Machines

User Manual

Page 2: VS-400 & VS-800 - Farnell element14 · VS-400 & VS-800 Smoke Machines Use anual 3 Product overview These compact smoke machines are ideal for small venues, house parties and mobile

www.prolight.co.uk VS-400 & VS-800 Smoke Machines User Manual 2

Safety advice

WARNING: FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.• Donotopentheequipmentanddonotmodifytheunit.• Donotswitchtheequipmentonandoffinshortintervals,

asthiswillreducethesystem’slife.• Onlyusetheequipmentindoors.• Donotexposetoflammablesources,liquidsorgases.• Alwaysdisconnectthepowerfromthemainswhen

equipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablevoltageisbetween220V~240V,50/60Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Iftheequipmenthasbeenexposedtodrastictemperaturefluctuation(e.g.aftertransportation),donotconnectpowerorswitchitonimmediately.Thearisingcondensationmightdamagetheequipment.Leavetheequipmentswitchedoffuntilithasreachedroomtemperature.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProlightdealerforservice.

• Onlyusefusesofsametypeandrating.• Repairs,servicingandpowerconnectionmustonlybe

carriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• WARRANTY:Oneyearfromdateofpurchase.

• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

CAUTION!KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

Beforefillingtheunitdisconnectthemains.Neverfillwithhotliquids.

Onlyusehighquality,waterbasedsmokefluidrecommendedbythemanufacturer.Othersmokefluidsmaycausecloggingandvoidtheguarantee.

Alwaysmakesurethereissufficientsmokefluidinthetank.Operatingthissmokemachinewithoutsmokefluidwillcausedamagetothepumpaswellasoverheatingoftheheater.

Operatetheunitonlyafteryouhavefamiliarisedyourselfwithitsfunctions.Donotpermitoperationbypersonsnotqualifiedforoperatingtheunitandalwaysdrainthetankandusetheoriginalpackagingiftheunitistobetransported.

IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

Page 3: VS-400 & VS-800 - Farnell element14 · VS-400 & VS-800 Smoke Machines Use anual 3 Product overview These compact smoke machines are ideal for small venues, house parties and mobile

www.prolight.co.uk VS-400 & VS-800 Smoke Machines User Manual 3

Product overview

Thesecompactsmokemachinesareidealforsmallvenues,housepartiesandmobileDJs.Theyhaveanextremelyfastwarm-uptimeandproduceanimpressivesmokeoutputtoprovidetheperfectatmosphere.Ahandheldremotecontrolisalsoincludedformanualoperation.

VS-400 & VS-800 Fogger Smoke Machines

Specifications VS-400 VS-800

Smokeoutput 2,000cu.ftperminute 4,000cu.ftperminute

Warm-uptime approx.2mins approx.4mins

Tankcapacity 0.25litre 1litre

Powerconsumption 400W 800W

Powersupply 240VAC,50/60Hz 240VAC,50/60Hz

Dimensions 240x144x150mm 325x186x222mm

Weight 1.75kg 3.4kg

Ordercode FOG11 FOG12Remotecontrol

Page 4: VS-400 & VS-800 - Farnell element14 · VS-400 & VS-800 Smoke Machines Use anual 3 Product overview These compact smoke machines are ideal for small venues, house parties and mobile

www.prolight.co.uk VS-400 & VS-800 Smoke Machines User Manual 4

O

I

www.prolight.co.uk

ADD FLUID

MAINS VOLTAGEREMOTE CONTROL

POWER SWITCH

240V~50HzFUSE: T3A 250V

01

Technical specifications

01-On/Offswitch

02-Remotecontrol(insocket)

03-Fluidlevel

04-IECpowerinsocket

05-Fuse:400W=T3A800W=T5A

Inthebox:1 x fixture, 1 x wired remote, 1 x power cable & 1 x user manual

0203

04

05

VS-400

O

I

www.prolight.co.uk

ADD FLUID

MAINS VOLTAGEREMOTE CONTROL

POWER SWITCH

240V~50HzFUSE: T3A 250V

01 03

02

04

05

VS-800

Page 5: VS-400 & VS-800 - Farnell element14 · VS-400 & VS-800 Smoke Machines Use anual 3 Product overview These compact smoke machines are ideal for small venues, house parties and mobile

www.prolight.co.uk VS-400 & VS-800 Smoke Machines User Manual 5

Operating instructions

Starting operation:

Installtheunitonalevelsurface.

Thefluidtankoftheunitneedstobefilledwithsmokefluidbeforeswitchingon.Alwaysdisconnecteditfromthemainssupplyasfluidcouldbespilled.

Onlyusequalitysmokefluidsrecommendedbyyourdealer.See page 7forourrecommendedhighqualitysmokefluids.Youmustnotusesubstanceswhichareclassifiedas‘DANGEROUS WORKING MATERIALS’or‘FLAMMABLE FLUIDS’.

Iffluidshouldgetinsidethemainhousing,disconnecttheunitfromthemainsimmediatelyandconsultatechnician.

Installation:

Installtheunitinawell-ventilatedarea.Useinaninsufficientlyventilatedroomcanleadtothecondensationofthesmokefluid.Theresultingslipperysurfacecancauseaccidents.Keepaminimumdistanceof50cmaroundtheunit.

Furthermoredonotorientatetheoutputnozzledirectlyinthedirectionoftheaudience’seyes.Inordertocreatethebesteffect,thereshouldbeadistancebetweentheunitandtheaudienceofatleast1.5m.

Onlyinstallthesmokemachineonfireresistant,scratchresistantandwaterresistantsurfaces.

Pleasemakesurethattheinstallationangledoesnotexceed15˚fromhorizontal.

Thisunitisconstructedforafreestandingorhanginginstallation.Iftheunitistobeinstalledoverhead,pleasefollowthesafetyinstructionsbelow:

Rigging installation:

Theinstallationhastobebuiltandconstructedinawaythatitcanhold10timestheweightoftheunit(s)tobeinstalledfor1hourwithoutanydeformation.

Theunitmustalwaysbesecuredwithasecondarysafetyattachment,e.g.anappropriatecatchnetorsafetywire.Thesecondarysafetyattachmentmustbeconstructedinawaythatnopartoftheinstalledunitcanfalldownifthemainattachmentfails.

Whenrigging,deriggingorservicing,donotallowpersonneltobedirectlyunderneaththeunit.

Theoperatormustalwaysmakesurethatthesafety-relatingandmachine-technicalinstallationsareapprovedbyanexpertbeforeoperationforthefirsttimeandafteranyfurtherchangesaremade.

Theoperatorhastomakesurethatthesafety-relatingandmachine-technicalinstallationsareapprovedbyaqualifiedpersononceayear.

DANGER OF FIRE!When installing the unit, make sure there is no highly flammable material

(decoration articles etc) within a minimum distance of 0.5m

Page 6: VS-400 & VS-800 - Farnell element14 · VS-400 & VS-800 Smoke Machines Use anual 3 Product overview These compact smoke machines are ideal for small venues, house parties and mobile

www.prolight.co.uk VS-400 & VS-800 Smoke Machines User Manual 6

Operating instructions

Procedure:

Whenhanging,theunitmustnotbeinstalledinareasabovewherepersonsmaywalkbyorbeseated.

IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE,including(butnotlimitedto)calculatingworkingloadlimits,installationmaterialsbeingused,andperiodicsafetyinspectionofallinstallationmaterialsandtheunit.Ifyouarenotqualified,donotattempttheinstallationyourself,butinsteaduseaprofessionalstructuralrigger.Improperinstallationcanresultinbodilyinjuryandordamagetoproperty.

Theunithastobeinstalledoutofthereachofpeople.

CAUTION:Unitsinoverheadinstallationsmaycausesevereinjurieswhenfalling!Ifyouhavedoubtsconcerningthesafetyofapossibleinstallation,donotinstalltheunit.

Mounttheunitwiththebrackettoyourhangingsystemusinganappropriateclamporbolt.

Foroverheaduse,alwaysinstallasafetywirewhichcanholdatleast12timestheweightoftheunit.Youmustonlyusesafetywireswithlinkscrewcaps.

Themaximumdropdistanceofanysafetybond(wire)mustneverexceed20cm.Asafetywirewhichhasalreadyheldthestrainofafallenitemorwhichisdefectivemustnotbeusedagain.

Adjustthedesiredinstallationangleviathemountingbracketandtightenthescrews.

Cleaning and maintenance:

Werecommendafrequentcleaningoftheunit.Pleaseuseasoftlint-freeandmoistenedcloth.Neverusealcoholorsolvents!Cleantheoutputnozzlefrequentlyfromsmokefluidresidues.Thefluidswerecommend(See page 7)arenon-hazardoustotheenvironmentandcanbedisposedofviathesewagesystem.

Therearenoserviceablepartsinsidethisunitexceptforthefuse.Maintenanceandserviceoperationsareonlytobecarriedoutbyauthorizeddealers.

Replacing the fuse:

Onlyreplacethefusewithafuseofsametypeandrating.

Before replacing the fuse, disconnect from the mains, see the following for procedure:

Step 1: Open the fuse holder on the rear panel with a suitable screwdriver. Step 2: Remove the old fuse from the fuse holder. Step 3: Install the new fuse in the fuse holder. (Replacement fuses should be of the same value as originally supplied) Step 4: Replace the fuse holder in the housing.

Shouldyouneedanyspareparts,onlyusegenuineparts.Ifdefective,pleasedisposeoftheunusableunitinaccordancewiththecurrentlegalregulations.

Shouldyouhaveanyfurtherquestions,pleasecontactyourdealer.

DANGER TO LIFE!Disconnect from the mains before starting maintenance

Page 7: VS-400 & VS-800 - Farnell element14 · VS-400 & VS-800 Smoke Machines Use anual 3 Product overview These compact smoke machines are ideal for small venues, house parties and mobile

www.prolight.co.uk VS-400 & VS-800 Smoke Machines User Manual 7

Operating instructions & Optional Fluid

Operation:Connectthefogmachinetoasuitablemainsoutletusingthe13A-IECpowercable.

Aftertheunithasbeenpoweredupthefogmachinewilltakeashortwhiletoheatuptooperatingtemperature.OnceheatedandreadyforusetheRed LEDontheremotewillilluminatetoindicatetheunitisReady to Fog.

Tobeginfoggingpressthebuttononthehandheldremotecontrol.TheGreen LEDwillilluminateontheremotecontroltoindicatethefogmachineisactiveandthepumpisrunning.Longperiodsofactivationmaytriggerthefogmachinetoenterthereheatcycleduringwhichthefogmachinewillnotproduceanyoutput.

Careshouldbetakentoensurethefluidlevelismaintainedandtheunitisnotallowedtorundryoffluid.Isolatefromthemainssupplybeforerefillingthefluidtank.

Fluid:Ourfluidisidealforusewithmostbrandsofwaterbasedfoggersandsmokemachines.

Leavesnoresidue,isnontoxicandismanufacturedfromfoodgradecomponentsinourUKlaboratory.

ThisindustrystandardfluidistheautomaticchoiceofDJsandbandsalike.Adensewhiteairbornefogisproducedwithamediumlengthdispersaltime.Itsmediumindexofrefractionmakesthisformulaidealforalleffects.

Remotecontrol

Pleasecontactyourlocalretailertopurchasetheseaccessories.

Version DJ Smoke Fluid PRO Smoke Fluid

Fluidamount 5litres 5litres

Forusewithmostwaterbasedfoggersandsmokema-chineswithheatersofupto1200W

Forusewithmostwaterbasedfoggersandsmokema-chineswithheatersofupto1800W

Ordercode FLUI21 FLUI22

Page 8: VS-400 & VS-800 - Farnell element14 · VS-400 & VS-800 Smoke Machines Use anual 3 Product overview These compact smoke machines are ideal for small venues, house parties and mobile

www.prolight.co.uk VS-400 & VS-800 Smoke Machines User Manual 8

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedofwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.