Top Banner
VIMA (Volatile Induction and Maintenance Anesthesia) How and Why James H. Philip M.E.(E), M.D. © Copyright 1995 - 2007, James H Philip, all rights reserved
102

(Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Mar 22, 2018

Download

Documents

phamkiet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

VIMA(Volatile Induction and Maintenance Anesthesia)

How and Why

James H. Philip M.E.(E), M.D.

© Copyright 1995 - 2007, James H Philip, all rights reserved

Page 2: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

VIMA(Volatile Induction and Maintenance Anesthesia)

How and Why

James H. Philip, M.E.(E.), M.D.Anesthesiologist and

Director of Bioengineering,Brigham and Women's Hospital

Associate Professor of Anaesthesia, Harvard Medical School

Medical Liaison, Partners Biomedical Engineering

Page 3: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Gas Man

Info:gasmanweb.com

I will u

se

Page 4: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Three unique uses for Sevoflurane

Almost uniqueSevoflurane SedationSevoflurane for a difficult airwaySevoflurane Vital Capacity Induction

Page 5: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sevoflurane Sedation

2 L/min FGFSevoflurane 2%PO Oral Ibuprofen (Advil, Motrin) $0.50

Page 6: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

It worksNo need for other drugs

IV Induction agent (Pent/Prop)OpioidMuscle relaxant (any NMB)Reversal agents for NMB

Why do VCI?

Page 7: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

No relaxants No Propofol

Page 8: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

No relaxants No Propofol

No use

Page 9: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

No relaxants No Propofol

No use

No waste

Page 10: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

InexpensiveSatisfying toPatientAnesthesiologistSurgeon

Why do VIMA?

Page 11: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Howto do

VolatileInduction

Page 12: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Premedication

None, typicallyAnything, as requiredTry talking, first

Page 13: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sedation possibility

Propofol 10 mgBWH Pharmacy makes 10 mL syringes2 mL syringes would be better

Page 14: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Volatile Induction

Fast*Volatile agent alone,

with or without nitrous oxideDeep breath

51 ± 4 seconds, 1 - 4 breaths39 ± 3 seconds, if 1 breath

* Philip BK, Lombard L, Calalang I, Philip J. Sevoflurane Vital Capacity Induction Compared with Propofol Intravenous Induction for AdultAmbulatory Anesthesia. Anesth & Analg 87:623-7, 1999.

Page 15: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

2 minute Preparation

Volatile Prime for anesthesia circuit

Oxygen Prime for lungs

Mental Prime for patient

Page 16: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Volatile Prime GoalPrime the circuit with8% Sevoflurane66 - 75% N2O

Page 17: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Semi-Closed CircuitVolatile Prime8% Sevoflurane1 L / min O2

3 L / min N2OPrime for 2 minutesSame time as pre-oxygenation

Page 18: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Volatile PrimeRequired to provide

sudden, large, controlledincrease ininspired anesthetic concentration

Inspired Control by any means is OKNew machines and techniquesmay make this easier

Page 19: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

How to do Volatile Prime

Page 20: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Volatile PrimeEmpty the circuitFGF = 0 - flows all offOpen relief (APL, pop-off) valveSqueeze bag to empty circuitAttach maskSeal mask

Glove, stopper, cork, plug, other

Page 21: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

One way - seal mask with glove

Page 22: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Another way -seal mask and circuit with tight-

fiting occluder

Page 23: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Prime the CircuitEmpty the circuit firstFGF=0Attach maskSeal maskOpen APL valve fullyEmpty reservoir bag through APL

Page 24: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Prime the CircuitEmpty the circuit firstFGF=0Attach maskSeal mask with glove Open APL valve fullyEmpty reservoir bag through APL Let reservoir bag fill

Page 25: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Normal flow in breathing circuit

Flow goes forwardIn the direction of the valvesEmptying and filling reservoir bagand lungs,alternately

Page 26: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

Exhaust

CO2

Ab-sorb-ant

200 mL/min

Fresh

Normal flow in the breathing circuit - Inspiration

Page 27: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

Exhaust

CO2

Ab-sorb-ant

200 mL/min

Fresh

Normal flow in the breathing circuit - Expiration

Page 28: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Priming the Circuit

Flow goes backwardsBlocked by each valveFilling the reservoir

Page 29: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

Exhaust

CO2

Ab-sorb-ant

200 mL/min

Fresh

Back-fill the breathing circuit (#1)

Page 30: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

Exhaust

CO2

Ab-sorb-ant

200 mL/min

Fresh

Back-fill the breathing circuit (#1)

Page 31: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

Exhaust

CO2

Ab-sorb-ant

200 mL/min

Fresh

Back-fill the breathing circuit (#1)

Page 32: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

Exhaust

CO2

Ab-sorb-ant

200 mL/min

Fresh

Empty the reservoir bag (#1)

Squeeze

Page 33: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

CO2

Ab-sorb-ant

Sampled

Exhaust

200 mL/min

Fresh

Fill the reservoir bag again (#2)

Page 34: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

CO2

Ab-sorb-ant

Sampled

Exhaust

200 mL/min

Fresh

Empty the reservoir bag (#2)

Page 35: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

CO2

Ab-sorb-ant

Sampled

Exhaust

200 mL/min

Fresh

Fill the reservoir bag again (#3)

Page 36: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

CO2

Ab-sorb-ant

Sampled

Exhaust

200 mL/min

Fresh

Close the Exhaust Valve

Page 37: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

Exhaust

CO2

Ab-sorb-ant

200 mL/min

Fresh

Empty reservoir bag (#3) and fill the inspired limb

Squeeze

Closed

Page 38: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

CO2

Ab-sorb-ant

200 mL/min

Fresh

Empty reservoir bag (#3) and fill the inspired limb

Squeeze

ExhaustClosed

Page 39: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

CO2

Ab-sorb-ant

200 mL/min

Fresh

Empty reservoir bag (#3) and fill the inspired limb

Squeeze

ExhaustClosed

Page 40: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

CO2

Ab-sorb-ant

200 mL/min

Fresh

Empty reservoir bag (#3) and fill the inspired limb

Squeeze

ExhaustClosed

Page 41: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

CO2

Ab-sorb-ant

200 mL/min

Fresh

Empty reservoir bag (#3) and fill the inspired limb

Squeeze

ExhaustClosed

Page 42: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

CO2

Ab-sorb-ant

200 mL/min

Fresh

Open the Exhaust - Fill the Expired Limb (#3)

Release

Page 43: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

CO2

Ab-sorb-ant

200 mL/min

Fresh

Open the Exhaust - Fill the Expired Limb (#3)

Release

Page 44: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sampled

Exhaust

CO2

Ab-sorb-ant

200 mL/min

Fresh

Remove Glove, Apply mask to patient (#4)

Release

Patient

Page 45: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Gas Monitor shows Circuit is Ready

Circuit is ready

Page 46: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Gas Monitor shows Circuit is Ready

Circuit is ready

After third bag-fill

Page 47: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Here is how to test when ckt is ready

Sampleto gas monitor

Page 48: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Sample from Reservoir Bag Attachment

Bag #

Page 49: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

2 minute Preparation

Volatile Prime for anesthesia circuit √

Oxygen Prime for lungs

Mental Prime for patient

Page 50: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

While priming circuitPreoxygenate

Page 51: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Simple Circuit

Page 52: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Simple parts

Page 53: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Simple parts

Reservoir bag(with cut end)

15-22mm adapter

Sampling(oxygenating)

Elbow

Oxygensource

Mask

Page 54: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Option in some countries:SiBI Connector

Skip the next 4 slides to skip this section

Facilitates pre-oxygenation during circuit prime

We have some at BWH

Page 55: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

SiBI(TM) Connector

Page 56: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

SiBI Close-up

Page 57: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

November 4, 2001 SiBI

Page 58: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

South Lake Regional Hosp Ont 01/22/02

Page 59: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Peak Inspired Agent MonitoringSome monitors report Inspired = Peak InspiredThis is a problem if Mean and Peak differMean is representative of what affects uptakeGE-Datex-Ohmeda ADU puts FGF after Insp ValveThis makes Mean and Peak differ greatly

Page 60: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

CO2

Ab-sorb-ant

Most ADS

Normal Breathing Circuit FGF path

I

E

Page 61: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

CO2

Ab-sorb-ant

ADU

GE “ADU” FGF path

I,E

Page 62: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

GE ADU wave data

Page 63: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

SiBI -> Ckt

InspExp

Exp

Insp

Page 64: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

SiBI -> Ckt

InspExp

Exp

Insp

Mean Inspired = 2%, different from 7.1% peak

Page 65: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Anesthetizes like 2%, not 7%

Page 66: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

2 minute Preparation

Volatile Prime for anesthesia circuit √

Oxygen Prime for lungs √

Mental Prime for patient

Page 67: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Mental Prime PatientInstruct and practice VCVC = Vital Capacity breath

Breathe all the way out Take a deep breath inHold it inMaintain positive verbal contact

Create positive experiencethrough words and actions

Page 68: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

2 minute Preparation is done

Volatile Prime for anesthesia circuit √

Oxygen Prime for lungs √

Mental Prime for patient √

Ready for Volatile Induction

Page 69: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

VI - Volatile InductionSay and DoSay: “Exhale”Do: Switch to Sevoflurane maskSay: “Inhale and hold inspiration”Do: Maintain positive verbal contact Maintain high (7%) inspired sevoflurane conc.

Page 70: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

> One Breath Induction

If patient breathes outInstruct patient to

take another deep breath and hold itTake another deep breath and hold itTake another deep breath and hold it

Page 71: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Data from BWH First Series

18 patients with perfect data for analysisIn first 20 seconds after VCISevoflurane %M SD

Inspired = 6.2 + 0.8Expired = 4.2 + 0.8

Nitrous OxideMean = 58 + 6

Most lost lash reflex in 1 breathSome required 2 breathsFew required 3 breaths

Page 72: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Anesthetize and Oxygenate togetherVCI Sevo 8% in Oxygen

Slightly slowerNo Second Gas EffectNo additional effect of N2O

Always quite adequateAllows same settings from VCI to airway securement (Tracheal Tube, LMA)

Page 73: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Volatile Induction Phase TwoDeepen Inhalation Anesthesia

After loss of consciousness in 1 minContinue induction with 8% SevoAssist or control ventilationPrepare to secure airway if desired

O2 + SevoSecure airway

LMA OK in 2 minutes ETT OK in 3 - 5 minutes (no relaxant)

Page 74: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Produce apnea before removing mask

Hyperventilate to apnea

Avoid losing anesthetic fromlungsbloodbrain

Page 75: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Or, keep anesthesia light

Natural airway orMinor airway interventions

Oropharyngeal airwayNasopharyngeal airway

Deepen anesthesia before incision

Page 76: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Monitor

CarefullyOftenBP q 1 minute (for a while)Always “automatic”

Page 77: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Induction is complete

Maintenance begins

Page 78: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

VM - Volatile Maintenance Anesthesia

We have always done thisMaintain desired anesthetic depthDecrease fresh gas flows to save costIncrease vaporizer settingMaintain previous expired anesthetic conc.Maintain previous anesthetic depthIncrease and decrease depth as requiredReact or anticipate

Page 79: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

VM - Volatile Maintenance Anesthesia

Depth = Constant + Adjust as requiredThree anesthetic conditions

Constant IncreaseDecrease

Page 80: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

VM - Volatile Maintenance Anesthesia

Depth = Constant + Adjust as requiredThree anesthetic conditions

Constant Increase Vaporizer to Max = 8%Decrease Vaporizer off = 0%Increase FGF if required

Readjust vaporizer to near prior setting

Overpressure

Underpressure

Page 81: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Up and downusing Overpressureand Underpressure

2

4

6

8

10

0-10 -20 -30

time (minutes)

I

E

Page 82: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

For short cases, remember

Awakening begins just after inductionDon’t be afraid to turn the vaporizer offBring expired concentration down to 1.3 MACKeep expired at 0.7 MAC near the very end

Page 83: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Prepare for recovery - always

Recovery begins with wake upRecovery ends with

patient back to normalNormal means normal -

Patient is satisfiedAnesthesiologist is satisfied Surgeon is satisfied

Page 84: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates
Page 85: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Volatile EmergenceVolatile emergence is smooth

Create and maintain zero (0.0) inspired agent concentrationEmpty the Reservoir Bag, Flush O2, High FGF

Ventilate anesthetic out of lungsMinute ventilation > 4 L/minpETCO2 around 36 mmHg

Page 86: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

FGF is low

Increase FGF

Problems occur with wake up if FGF or Ventilation is low

Poor circuitwash out;FGF too low

Page 87: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Ventilation is lowProblems occur with wake up if FGF or Ventilation is low

Poor lung wash out.Ventilation is too low

Page 88: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Better wake up w experience

Usually, wake up is better

Low inspiredLow expired

Page 89: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

1.0

.2

.4

.6

.8

0.00 Minutes of administration 30

A/I

Data from Yasuda & Eger, 1991

Zerothane 0.88

0.71

0.56

0.83

Volatile InductionDes

Sev

Iso

Hal FE

F I

Page 90: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

0 Minutes of discontinuation 30

A/I0 Zerothane

Alveolar response to inspired = 0

0.12

0.29

0.44

0.17

0.0

.8

.6

.4

.2

1.0

FE

FE0

After a long anesthetic

Volatile Emergence

DesSev

Iso

Hal

Page 91: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

0 Minutes of discontinuation 30

A/I0 Zerothane

Alveolar response to inspired = 0

0.12

0.29

0.44

0.17

0.0

.8

.6

.4

.2

1.0

FE

FE0

After a long anesthetic

0.33 MACAwake

Volatile Emergence

DesSev

Iso

Hal

Page 92: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

0 Minutes of discontinuation 30

A/I0 Zerothane

Alveolar response to inspired = 0

0.12

0.29

0.44

0.17

0.0

.8

.6

.4

.2

1.0

FE

FE0

After a long anesthetic

0.20MACclimb to strether (approx)

Volatile Emergence

DesSev

Iso

Hal

0.33 MACAwake

Page 93: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

No need forIV Induction agentOpioidMuscle relaxant (NMB)Reversal agents for NMBOther drugsComplications

Avoid Side EffectsAvoid Costs

Clinical Benefits of VIMA

Page 94: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

VIMA providesDeep anesthesia from beginning to endNo additional drugs for intubationNo additional drugs for intra-op painRapid awakening and return to normalPost-op pain requires local anesthesia infiltration

anesthesia and post-op analgesic

Page 95: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

How toavoid slow wake ups

Page 96: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

FGF is low

Increase FGF

Problems occur with wake up if FGF or Ventilation is low

Poor circuitwash out;FGF too low

Page 97: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Ventilation is lowProblems occur with wake up if FGF or Ventilation is low

Poor lung wash out.Ventilation is too low

Page 98: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Better wake up w experience

Usually, wake up is better

Page 99: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Better wake up w experience

Usually, wake up is better

Low inspiredLow expired

Page 100: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

SummaryVIMA is Volatile Induction and Maintenance Anesthesia.VIMA is an acceptable equivalent alternative to IV plus Volatile combinations.VIMA preparation requires 2 minutes for circuit anesthetic prime, lung oxygen prime, and brain psychological prime.VIMA Sevoflurane induction is faster than IV Propofol (51 ± 4 sec vs. 81 ± 12 sec).VIMA wake up is as fast and uncomplicated as Propofol induction and VM anesthesia.

Page 101: (Volatile Induction and Maintenance Anesthesia) How …etherweb.bwh.harvard.edu/education/PHILIP/VIMA_How_and...SiBI Connector Skip the next 4 slides to skip this section Facilitates

Thank you