1 VistA Imaging Approved DICOM Modality Interfaces October 2016 VistA Imaging has successfully tested many modalities and interfaced them to VistA using DICOM. The following list of approved DICOM modalities was generated based on the most current information and will change as more information becomes available. A DICOM modality is considered “Supported” if it passes the VA’s internet validation test suite listed in the Joint VA/DoD DICOM Modality Conformance Requirements (Rev 3.0) document. Some modalities have superscript numbers in the Status column which refer to the notes at the bottom of the table. If the software used on a modality is revised by the manufacturer, the modality will need to be re-validated. The VA retains the right to change modality testing requirements at any time as needed for VA medical care. These changes could require re-testing of the modalities. VA facilities are required to complete a quality review for the images produced by the device before it may be placed into clinical use. The results of the quality review must be filed with the National VistA Imaging Project Office. This list of approved DICOM modalities does not in any way constitute a product endorsement by the VA. It only states whether or not the listed product has passed the VA’s internet-based validation testing. Upgrades to the vendor devices can affect interoperability and may require re-validation. The validation process does not indicate how well the actual product will work operationally, either within the VA or elsewhere. Modality/Device Types Approved modalities and devices are grouped into the categories listed below. A list of approved devices for each category can be found on the page listed below. Bone Density ......................................................2 Cardiology ..........................................................2 CD/DVD Burners ...............................................2 Computed Radiography ......................................2 Computed Tomography ......................................5 Dental Extra-Oral Radiography ..........................6 Dental Intra-Oral Radiography ...........................8 Dental VL – Endoscopy………………………. 8 Dental Workstations ...........................................9 Digital Subtraction ..............................................9 Direct X-Ray.....................................................10 Evidence Creator (Encapsulated PDF) .............12 Film Digitizer ...................................................13 Film Digitizer Software ....................................13 Frame Grabber ..................................................14 General Microscopy..........................................14 Magnetic Resonance .........................................15 Mammography..................................................17 Middleware – Interface Engine.........................18 Nuclear Medicine..............................................19 Nuclear Medicine - SPECT ..............................19 Ophthalmic Photography ..................................20 Ophthalmic Ultrasound..................................... 21 Ophthalmic Workstation……………………...21 Optical Coherence Tomography (Ophthalmology use only).................................................................. 21 Other ................................................................. 22 PET ................................................................... 22 PET/CT ............................................................. 23 PET/MR............................................................ 23 Q/R – 3D Reconstruction Workstation..............23 Q/R – Planning Workstation ............................. 24 Q/R – Routers ................................................... 24 Q/R – Workstations ........................................ 255 Radio Fluoroscopy and X-Ray Angiography . 266 Secondary Capture............................................ 26 Secondary Capture (Injection Dosage Capture) 28 Surgical Workstation………………………….28 Ultrasound ........................................................ 29 Visual Field Analyzer (Encapsulated PDF) .... 311 VL – Endoscopy ............................................. 312 VL – Endoscopy/Microscopy ......................... 322 VL – Pathology............................................... 322 Notes ............................................................... 322
32
Embed
VistA Imaging Approved DICOM Modality Interfaces Imaging_DICOM_Modality...1 . VistA Imaging Approved DICOM Modality Interfaces . October 2016 . VistA Imaging has successfully tested
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1
VistA Imaging Approved DICOM Modality Interfaces October 2016
VistA Imaging has successfully tested many modalities and interfaced them to VistA using DICOM. The following list of approved DICOM modalities was generated based on the most current information and will change as more information becomes available. A DICOM modality is considered “Supported” if it passes the VA’s internet validation test suite listed in the Joint VA/DoD DICOM Modality Conformance Requirements (Rev 3.0) document. Some modalities have superscript numbers in the Status column which refer to the notes at the bottom of the table. If the software used on a modality is revised by the manufacturer, the modality will need to be re-validated. The VA retains the right to change modality testing requirements at any time as needed for VA medical care. These changes could require re-testing of the modalities. VA facilities are required to complete a quality review for the images produced by the device before it may be placed into clinical use. The results of the quality review must be filed with the National VistA Imaging Project Office. This list of approved DICOM modalities does not in any way constitute a product endorsement by the VA. It only states whether or not the listed product has passed the VA’s internet-based validation testing. Upgrades to the vendor devices can affect interoperability and may require re-validation. The validation process does not indicate how well the actual product will work operationally, either within the VA or elsewhere.
Modality/Device Types Approved modalities and devices are grouped into the categories listed below. A list of approved devices for each category can be found on the page listed below. Bone Density ......................................................2 Cardiology ..........................................................2 CD/DVD Burners ...............................................2 Computed Radiography ......................................2 Computed Tomography ......................................5 Dental Extra-Oral Radiography ..........................6 Dental Intra-Oral Radiography ...........................8 Dental VL – Endoscopy………………………. 8 Dental Workstations ...........................................9 Digital Subtraction ..............................................9 Direct X-Ray ..................................................... 10 Evidence Creator (Encapsulated PDF) ............. 12 Film Digitizer ................................................... 13 Film Digitizer Software .................................... 13 Frame Grabber .................................................. 14 General Microscopy .......................................... 14 Magnetic Resonance ......................................... 15 Mammography .................................................. 17 Middleware – Interface Engine ......................... 18 Nuclear Medicine .............................................. 19 Nuclear Medicine - SPECT .............................. 19 Ophthalmic Photography .................................. 20
Bone Density Supported Bone Density Devices Manufacturer Model Status GE DPX Bravo Supported GE DPX Duo Supported GE DPX-MD+ Supported GE DPX-NT Supported GE Lunar iDXA Supported GE Prodigy Advance Supported GE Prodigy Primo Supported GE Prodigy Pro Supported GE/Lunar Prodigy Supported Hologic Discovery Supported Hologic Horizon Supported Hologic Explorer Supported Hologic Oasis (QDR) Workstation Supported Norland Excell (IlluminatusDXA) Supported Norland XR-46 (IlluminatusDXA) Supported Norland XR-600 (IlluminatusDXA) Supported Norland XR-800 (IlluminatusDXA) Supported Notes
Cardiology Supported Cardiology Devices Manufacturer Model Status GE Innova IGS 520 Supported GE Innova IGS 530 Supported GE Innova IGS 540 Supported GE Innova IGS 620 Supported GE Innova IGS 630 Supported GE Discovery IGS 730 Supported GE Discovery IGS 740 Supported Notes
CD/DVD Burners Supported CD/DVD Burners Manufacturer Model Status Pacsgear Media Writer D100/D200 Supported1 RadInfo Systems CDPowerPACS Supported2 Sencor DICOM Part 10 Burner Supported Sorna FilmX Supported Sorna eXpedo Supported Sorna Vertex Supported Notes 1 Uses DICOM software that was approved for Pacsgear and Pacscan 2 Device now supported by Sorna
Computed Radiography Supported Computed Radiography Devices Manufacturer Model Status Agfa ADC-51xx Supported Agfa ADC 70 Supported4 Agfa ADC Compact Supported4 Agfa ADC Solo Supported4
Orex ACL2 and ACL4 Supported4 Philips AC3 Supported4 Philips Compano PCR Supported Philips PCR Corada Supported Philips PCR Eleva Supported Siemens AC3 Supported4 Siemens Multix FD Supported Viztek Onyx Rad workstation Supported Notes 1 No DICOM Modality Worklist capability. 4 Data is transferred via an intermediary device. Confirm intermediary device was purchased as well. 5 Tested as DICOM Object. Test images were not converted to Targa format. 8 Only supplies Modality Worklist.
5
Computed Tomography Supported Computed Tomography Devices Manufacturer Model Status Carestream CS 8100 3D Trophy 6.4 Supported Carestream CS 9300 Trophy 6.4 Supported Elscint CT Twin Supported Elscint OmniPro Supported GE Brightspeed (ALL) Supported GE CT/I Supported1 GE Discovery CT660 Supported GE Discovery CT750 HD Supported GE Discovery 590 (RT) Supported GE Gensys Supported GE HiSpeed CT/I Supported GE HiSpeed RP Supported GE Jupiter Supported GE Lightspeed (ALL) Supported GE Optima 520/540 Supported GE Revolution Supported GE Revolution Evo Supported GE Revolution HD Supported GE Revolution GSI Supported Hitachi Medical Corporation Scenaria Supported Marconi PQ2000 Supported Marconi PQ5000 Supported Marconi PQ6000 Supported Marconi PQS Supported Marconi TomoScan Supported1, 3 Marconi Ultra Z Supported10 Marconi/Philips Extended Brilliance Supported Marconi/Philips MX8000 Supported Marconi/Philips MX8000 IDT Supported NeuroLogica Corp. BoadyTom Portable CT Supported NeuroLogica Corp. CereTom Portable CT Supported NeuViz CT16 Supported NeuViz NV64 Supported Philips Brilliance 40 CT Supported Philips Brilliance 64 CT Supported Philips Brilliance CT Supported Philips Brilliance iCT Supported Philips Brilliance Ingenuity CT Supported Philips Brilliance Portal Supported17 Philips Brilliance Workspace Supported17 Philips Extended Brilliance Workspace Supported17 Philips MxViewEXP Supported Siemens CT Definition Supported Siemens Definition Flash Supported Siemens Emotion 6 Supported Siemens Emotion 16 Supported Siemens Sensation 10 Supported Siemens Sensation 16 Supported Siemens Sensation Cardiac Supported Siemens SOMATOM Supported1, 3
Digital Subtraction Supported Digital Subtraction Devices Manufacturer Model Status Philips Integris Supported Siemens AngioStar Supported Siemens Polytron Supported Notes None
10
Direct X-Ray Supported Direct X-Ray Devices Manufacturer Model Status Agfa DX-D 100 (Platform: NX) Supported Agfa DX-D 300 (Platform: NX) Supported Agfa DX-D 400 (Platform: NX) Supported Agfa DX-D 500n (Platform: NX) Supported Agfa DX-D 600 (Platform: NX) Supported Agfa DR 400 Supported Agfa DR 600 Supported Agfa Instant DR Retrofit Supported Canon CXDI Supported Canon CXDI Control NE Supported Canon RadPRO Elite XA (w/CDXI Control NE) Supported Canon RadPRO Elite XM (w/CDXI Control NE) Supported Canon RadPRO Elite FM1 (w/CDXI Control NE) Supported Canon RadPRO Mobile 40kW (w/CDXI Control NE) Supported Canon RadPRO Mobile 40kW Flex (w/CDXI Control NE) Supported Canon RadPRO Mobile 40kW Flex Plus (w/CDXI Control NE) Supported Canon RadPRO Omnera 400A (w/CDXI Control NE) Supported Canon RadPRO Omnera 400T (w/CDXI Control NE) Supported Canon RadPRO Delinia 200 (w/CDXI Control NE) Supported Canon RadPRO Soltus 100M (w/CDXI Control NE) Supported Canon RadPRO Soltus 100 (w/CDXI Control NE) Supported Canon RadPRO URS (w/CDXI Control NE) Supported Carestream DR7500 Supported Carestream DRX-1 Supported Carestream DRX-Evolution Supported Carestream DRX-Revolution Supported Carestream DR 3500 Supported Carestream DR 9500 Supported Carestream DRX-Mobile Retrofit Kit Supported DEL Medical DelWorks Medical DR System Supported CMT SmartRAD Supported Fuji AcSelerate (Platform: FDX Console) Supported Fuji Console Advance - DR-ID 300CL Supported Fuji Console Advance - DR-ID 300CL (Platform: FDX Console) Supported Fuji D-EVO (Platform: FDX Console) Supported Fuji Unity Supported Fuji Velocity Supported GE ADS_1.0 Supported GE Definium 5000 Supported GE Definium 8000 Supported GE Definium AMX700 Supported GE Discovery XR 650 (Platform Discovery XR) Supported GE Discovery XR 656 (Platform Discovery XR) Supported GE Discovery XR656+ Supported GE Discovery XR 650 (Platform Discovery XR) Supported GE Optima 220 (Platform Discovery XR) Supported GE Optima XR646 Supported GE Proteus US Supported GE Revolution XQ/i Supported GE Revolution XRd Supported
Evidence Creator (Encapsulated PDF) Supported Encapsulated PDF Devices Manufacturer Model Status Endosoft (UTECH) Endosoft Systems Supported Medima Solutions PacsPrinter Supported NeuroCom International BASIC Balance Master Supported NeuroCom International BASIC Balance Master (Platform: Balance Manager) Supported NeuroCom International Balance Master Supported NeuroCom International Balance Master (Platform: Balance Manager) Supported NeuroCom International EquiTest Supported NeuroCom International EquiTest (Platform: Balance Manager) Supported NeuroCom International EquiTest CRS Supported NeuroCom International EquiTest CRS (Platform: Balance Manager) Supported NeuroCom International inVision Supported NeuroCom International inVision (Platform: Balance Manager) Supported NeuroCom International PRO Balance Master Supported NeuroCom International PRO Balance Master (Platform: Balance Manager) Supported NeuroCom International SMART Balance Master Supported NeuroCom International SMART Balance Master (Platform: Balance Manager) Supported NeuroCom International SMART EquiTest Supported NeuroCom International SMART EquiTest (Platform: Balance Manager) Supported NeuroCom International SMART EquiTest CRS Supported NeuroCom International SMART EquiTest CRS (Platform: Balance Manager) Supported NeuroCom International VSR Supported NeuroCom International VSR (Platform: Balance Manager) Supported Notes None
13
Film Digitizer Supported Film Digitizers Manufacturer Model Status Array Corporation AR2905 Supported4 Hologic, Inc. Digital Now Film Scanner (MG) Supported5 Lumisys LS7 Supported4 Lumisys LS85 Supported4 Lumisys LS150 Supported4 Lumisys LS200 Supported4 Vidar Film Digitizer Supported4 Notes 4 Data is transferred via an intermediary device. Confirm intermediary device was purchased as well. 5 Tested as DICOM Object. Test images were not converted to Targa format.
Film Digitizer Software Supported Film Digitizer Software Manufacturer Model Status Lumisys DI-2000 Supported Mitra Mitra Express Supported Vidar Clinical Express Supported Notes None
14
Frame Grabber Supported Frame Grabbers Manufacturer Model Status ALI NewPort Supported Aspect Electronics See Kodak MIM Supported1 Camtronics NT-100 Supported1 Camtronics NT-200 Supported1 DicomIt Information Manager Supported Foresight Imaging formerly Imagraph HI-Def Plus Obsolete Foresight Imaging TIMS DICOM SYSTEM Supported Kodak MIM Supported Kodak MIMS-100 Supported Kodak MIMS-200 Supported RIS I2000 VICS Supported2 Notes 1 No DICOM Modality Worklist capability. 2 Poor DICOM Modality Worklist capability.
General Microscopy Supported General Microscopy Devices Manufacturer Model Status STI Hawaii, Inc. STI-Colposcope Supported Notes None
15
Magnetic Resonance Supported Magnetic Resonance Devices Manufacturer Model Status GE ADW Supported GE Discovery MR 450 Supported GE Discovery MR 750 Supported GE Discovery MR 750W Supported GE Optima MR430S Supported GE Optima MR 450 Supported GE Optima MR 450w Supported GE Signa Supported GE Signa HDe Supported GE Signa HDe 1.5T (14.0) (Platform: Signa HD) Supported GE Signa HDi Supported GE Signa HDi 1.5T (14.0) (Platform: Signa HD) Supported GE Signa HDx Supported GE Signa HDx 1.5T (14.0) (Platform: Signa HD) Supported GE Signa HDx 3.0T (14.0) (Platform: Signa HD) Supported GE Signa Ovation HD (14.0) (Platform: Signa HD) Supported GE Signa Profile Supported GE Signa Profile HD (14.0) (Platform: Signa HD) Supported GE ONI Medical Systems MR 430 Supported GE ONI Medical Systems MSK Extreme Supported Hitachi AIRIS II Supported Hitachi AIRIS Elite Supported Hitachi Altaire Supported Hitachi Echelon Supported Hitachi Echelon Oval Supported Hitachi Oasis Supported Hitachi Oasis XP Supported Marconi Eclipse 1.5T Supported Marconi Edge/Asset Supported Marconi Edge Supported Marconi Vista Supported Philips Achieva Supported Philips GyroScan Supported Philips GyroScanNT Supported Philips Gyroscan Intera Supported Philips Ingenia Supported Philips Intera Supported Philips Invivo DynaCad Supported5 Philips Panorama Supported Siemens Allegra Supported Siemens Avanto (syngoMR) Supported Siemens Concerto Supported Siemens Espree (syngoMR) Supported Siemens GBS III Supported3 Siemens Harmony Supported Siemens Impact Supported Siemens MAGNETOM Supported3 Siemens MAGNETOM Aera Supported Siemens MAGNETOM Amira Supported Siemens MAGNETOM Skyra Supported
16
Siemens MAGNETOM Verio Supported Siemens MAGNETOM -Vision Supported3 Siemens MAGNETOM Skyrafit Supported Siemens MAGNETOM Avantofit Supported Siemen MAGNETOM Prismafit Supported Siemens MAGNETOM Prisma Supported Siemens Sonata Supported Siemens Symphony Supported Siemens syngoMR Supported Siemens Trio (syngoMR) Supported Toshiba Excelart Vantage (MRT-1503) Supported Toshiba Excelart Vantage Atlas (MRT-1503) Supported Toshiba Excelart Vantage Titan (MRT-1504) Supported Toshiba Vantage Elan 1.5T Supported Toshiba Vantage Titan 1.5T Supported4 Toshiba Vantage Titan 3T Supported4 Notes 3 Tested using the DeJarnette Netshare for interfacing. Supported 4 “MPower” platform MR for Toshiba validated 5 Invivo DynaCad does not perform MWL, it is a Vista Storage only.
17
Mammography Supported Mammography Devices Manufacturer Model Status GE Senographe Essential Supported5 Hologic Cenova (CAD – Secondary Capture) Supported Hologic Multicare Platinum Supported Hologic SecureView Diagnostic Mammography Workstation Supported5,17 Hologic Selenia Dimensions (Selenia Dimensions V1.0 platform) Supported5 Hologic Selenia Dimensions Supported5 Hologic Trident RC Specimen Workstation Supported Siemens Mammomat Fusion/Inspiration Supported Siemens Mammomat Inspiration Supported Notes 5 Tested as DICOM Object. Test images were not converted to Targa format. 17 DICOM Query/Retrieve – Study/Root Q/R fully supported.
18
Middleware – Interface Engine Supported Middleware – Interface Engines Manufacturer Model Status Access AAM Supported Agfa Impax AS3000 Supported1 Agfa Impax DS3000 Supported1 Agfa Impax NG3000 Supported1 Carl Zeiss Meditec, Inc FORUM Supported DeJarnette ImageshareCR Supported DeJarnette MediShare Supported IMAGE Information Systems iQ-WEBX Supported IMAGE Information Systems iQ-VIEW Supported InfiMed GoldOne Supported2 InfiMed PlatinumOne Supported Foresight Imaging LLC TIMS 2000 SP Supported Kodak Cluster Server Supported Medtronics Stealth Station S7 Supported Merge Technologies Examworks Supported Merge Technologies MVP Supported Mitra Agfa PACS Broker Supported Mitra GE PACS Broker Supported Mitra PACS Broker Supported Mitra Picker PACS Broker Supported PACSGEAR (formerly NAI) DICOM Box Supported PACSGEAR PacsSCAN Supported PACSGEAR PacsSCAN Film Supported VIASYS Vasoguard Supported Visual-Med DicomPush Supported Notes 1 No DICOM Modality Worklist capability. 2 Poor DICOM Modality Worklist capability.
19
Nuclear Medicine Supported Nuclear Medicine Devices Manufacturer Model Status ADAC Forte Supported4 ADAC Genie Supported1 ADAC Pegasys (Wks.) Supported2 ADAC Solus Supported4 ADAC Vertex Supported4 Biodex Medical Systems, Inc Atomlab 960 Thyroid Uptake System Supported Capintec Captus 3000 (Thyroid Uptake System) Supported Digirad Corporation Prominence (See Digirad SeeQuanta) Supported Digirad Corporation SeeQuanta (DICOM Modality Worklist software) Supported4 Elscint Expert Supported GE Discovery NM 530c Supported GE Discovery NM 570c Supported GE Discovery NM 630 Supported GE Infinia Camera Supported4 GE Hawkeye Camera Supported4 GE Starcam Supported GE Varicam Supported GE Ventri Camera Supported4 GE Xeleris workstation Supported GE Xeleris 2 Workstation Supported GE Xeleris 3 Workstation Supported Marconi IRIX Supported Marconi Odyssey Supported1 Marconi P3000 Supported4 Marconi XP2000 Supported4 Pinestar Technologies NMIS DMWL Supported4 ec² Software Solutions NMIS DMWL Supported5 Philips Brightview Gamma Camera Supported4 Philips CardioMD Supported4 Philips JetStream Supported Philips Precedence Supported Siemens ICON workstation Supported1 Siemens Orbiter Supported Trionix Research BIAD Supported Trionix Research BIAD_24 Supported Trionix Research TRIAD Supported Notes 1 No DICOM Modality Worklist capability. 2 Poor DICOM Modality Worklist capability. 4 Data transferred via an intermediary device. Confirm intermediary device was purchased as well. 5. HL7 interface for MWL only.
Nuclear Medicine - SPECT Supported Nuclear Medicine – SPECT Manufacturer Model Status GE Brivo NM 615 (NM 600 Platform) Supported GE Discovery NM 630 (NM 600 Platform) Supported GE NM 600 Series (Platform) Supported GE Discovery NM/CT 670 Supported GE Discovery NM/CT 670 Pro Supported GE Discovery NM/CT 670 ES Supported
20
GE Optima NM/CT 640 (NM 600 Platform) Supported GE Vision POWERstation Supported Philips Brightview XCT Supported Philips Extended Brilliance Workplace Supported Siemens e.soft Supported Siemens Symbia E (eSoft Platform) Supported Siemens Symbia eSoft Platform (v8.5) Supported Siemens Symbia S (eSoft Platform) Supported Siemens Symbia T (eSoft Platform) Supported Siemens Symbia T2 (eSoft Platform) Supported Siemens Symbia T6 (eSoft Platform) Supported Siemens Symbia T16 (eSoft Platform) Supported Siemens Symbia E (syngo MI Applications platform) Supported Siemens Symbia Evo (syngo MI Applications platform) Supported Siemens Symbia Evo Excel (syngo MI Applications platform) Supported Siemens Symbia S (syngo MI Applications platform) Supported Spectrum-Dynamics DSPECT Supported
Ophthalmic Photography Supported Ophthalmic Photography Devices Manufacturer Model Status Canon CF1 (MYD) w/imageSPECTRUM Capture Plus v.5.0 Supported Canon CF1 (MYD) w/imageSPECTRUM Review v.5.1 Supported Canon CR1 Camera (non-MYD) Supported Canon CR1 Mark II (non-MYD) Supported Canon CR2 (Platform-Retinal Imaging Control 3.2) Supported Canon CR2 Plus (Platform-Retinal Imaging Control 3.2) Supported Canon CX1 (Platform-Retinal Imaging Control) Supported Canon EyeQ Pro Supported Canon CR2 (Platform-Retinal Imaging Control 4.1) Supported Canon CR-2 Plus AF (Platform-Retinal Imaging Control 4.1) Supported Canon CX-1 (Hybrid) w/imageSPECTRUM Capture Plus Version 5.0 Supported Canon CX-1 (Hybrid) w/imageSPECTRUM Review Version 5.1 Supported Canon CR2 w/imageSPECTRUM Capture Plus Version 5.0 Supported Canon CR-2 Plus AF w/imageSPECTRUM Capture Plus Version 5.0 Supported Canon CR-2 Plus AF w/imageSPECTRUM Review Version 5.1 Supported Canon CR-2 AF w/imageSPECTRUM Review Version 5.1 Supported Carl Zeiss Meditec, Inc. IOL Master 500 Supported 15,18 Carl Zeiss Meditec, Inc. VISUCAM Supported Carl Zeiss Meditec, Inc. VISUPAC Supported Carl Zeiss Meditec, Inc. FORUM Supported Chace and Associates Technologies, LLC ZPIP Supported Escalon Ophthavision Supported Estenda JVN Supported Haag Streit EyeCap Supported Kowa VKDICOM Supported Kowa VK-2 Supported Medflow oiCapture Supported15 Medflow MFCapture Supported Nidek 3Dx Supported Nidek (PACSPLUS) AFC 210/230 (PPdicom300E) Supported
Ophthalmic Ultrasound Supported Ophthalmic Ultrasound Devices Manufacturer Model Status Ellex Medical Pty Ltd Eyecubed Supported Ophthalmic Technologies, Inc. OTI-SCAN Supported Ophthalmic Technologies, Inc. OTI-SCAN 1000 Supported Ophthalmic Technologies, Inc. OTI-SCAN 2000 Supported Notes None
Ophthalmic Workstation Supported Ophthalmic Data Management Workstation Manufacturer Model Status Haag-Streit AG EYESUITE Supported Topcon Synergy Supported Topcon 3D-OCT Supported18
Optical Coherence Tomography (Ophthalmology use only) Supported Ophthalmic Coherence Tomography Devices Manufacturer Model Status Carl Zeiss Meditec, Inc. Cirrus HD-OCT 400/4000 Supported18 Carl Zeiss Meditec, Inc. Cirrus HD-OCT 500/5000 Supported18 Carl Zeiss Meditec, Inc. Cirrus HD-OCT Ver 9.0 Supported18 Heidelberg Engineering Spectralis HRA + OCT Supported Heidelberg Engineering Spectralis OCT Supported Ophthalmic Technologies, Inc... OCT Ophthalmoscope Supported Optovue XR Avanti w/DICOM Module 2.1+ Supported Optovue iCAM w/DICOM Module 2.1+ Supported Optovue iVue w/DICOM Module 2.1+ Supported Optovue RTVue w/DICOM Module 2.1+ Supported Optovue iScan w/DICOM Module 2.1+ Supported Notes: 18 DICOM Encapsulated PDF
22
Other Other Supported Devices Manufacturer Model Status DesAcc, Inc. Health Data Explorer Supported
Toshiba Ultimax (w/ADR-1000A) Supported Villa Sistemi Medicali Villa Apollo DRF Supported Ziehm Imaging 7000Plus Supported4 Ziehm Imaging 8000 Supported4 Ziehm Imaging NetPort (Platform Netport) Supported Ziehm Imaging NetPort (workstation) Supported Ziehm Imaging Vario 3D Supported4 Ziehm Imaging Ziehm Solo (Platform Netport) Supported Ziehm Imaging Ziehm Vision (Platform Netport) Supported Ziehm Imaging Ziehm Vision FD (Platform Netport) Supported Ziehm Imaging Ziehm Vision FD Vario 3D (Platform Netport) Supported Ziehm Imaging Ziehm Vision R (Platform Netport) Supported Ziehm Imaging Ziehm Vision RDF (Platform Netport) Supported Ziehm Imaging Ziehm Vision Vario 3D(Platform Netport) Supported Ziehm Imaging Vista Supported4 Ziehm Imaging VistaPlus Supported4 Notes
2 Poor DICOM Modality Worklist capability. 4 Data transferred via an intermediary device. Confirm intermediary device was purchased as well. 9 Automatic measurements may not be possible; manual calibration may be required. 17 DICOM Query/Retrieve – Study/Root Q/R fully supported.
Secondary Capture Supported Secondary Capture Devices Manufacturer Model Status Aranz Medical Limited SilhouetteLink Supported Bar-Code DICOMVIDEO Supported Biodex Medical Systems, Inc Atomlab 960 Thyroid Uptake System Supported E-Web Information Co. DICOM Engine Supported GE ViewPoint Supported1 Global Media Group, LLC CapSure CONI Supported Global Media Group, LLC CapSure Vista Supported Global Media Group, LLC CapSure Version 2.1.6.1 Supported Global Media Group, LLC CapSure Version 3.0 Supported Laborie Urodynamics System Supported2 Life-Tech, Inc. Urodynamics System Supported Life-Tech, Inc. Urodynamics System V/IV Supported Riverain Medical Softview (Bone Suppression SW) Supported Sapheneia Clarity Server (Router) Supported Notes
Manufacturer Model Status Bayer or Medrad Connect_PACS Supported Notes None
Surgical Workstation Manufacturer Model Status ImageStream nCare Supported Notes None
29
Ultrasound Supported Ultrasound Devices Manufacturer Model Status Accutome 4 Sight Supported Acuson 128-XP Supported5 Acuson KinetDX Supported5 Acuson Sequoia Supported5, 9 Siemens (Acuson) Sequoia Supported5, 9 ALI NewPORT Supported ATL 3000 Supported1, 5 ATL 5000 Supported5 BK Ultrasound (formerly BK Medical) Flex Focus 1202 Supported9 BK Ultrasound (formerly BK Medical) ProFocus 2202 Supported BK Ultrasound BK2300/3000/5000 Supported CorVascular Falcon Supported Digisonics DDI (Digisonics DICOM Implementation) Supported17 Esaote (Biosound) MyLab20 Plus Supported5, 9 Esaote (Biosound) MyLab25 Supported5, 9 Esaote (Biosound) MyLab30 Supported5, 9 Esaote (Biosound) MyLab40 Supported5, 9 Esaote (Biosound) MyLab50 Supported5, 9 Esaote (Biosound) MyLab60 Supported5, 9 Esaote (Biosound) MyLab70 Supported5, 9 Esaote (Biosound) MyLab70 XVG Supported5, 9 Esaote (Biosound) MyLab Class C (Platform: Mylab v4.1; v4.3) Supported5, 9 Esaote (Biosound) MyLab Five Supported5, 9 Esaote (Biosound) MyLab One (Platform: Mylab v4.1; v4.3) Supported5, 9 Esaote (Biosound) MyLab Twice (Platform: Mylab v4.1; v4.3) Supported5, 9 GE Healthcare (U-SYSTEMS) Invenia ABUS Supported GE Healthcare Echopac Supported9 GE Healthcare LOGIQ7 Supported5 GE Healthcare LOGIQS7 Supported GE Healthcare LOGIQ 400 Supported5 GE Healthcare LOGIQ 500 Supported5 GE Healthcare LOGIQ 700 Supported5 GE Healthcare LOGIQ Book Supported9 GE Healthcare LOGIQ E Supported9 GE Healthcare LOGIQ E9 Supported9 GE Healthcare LOGIQ P5 Supported GE Healthcare LOGIQ P6 Supported9 GE Healthcare LOGIQ S8 Supported5,9 GE Healthcare VIVID S6 Supported GE Healthcare VIVID 7 Supported9 GE Healthcare VOLUSONI (V730) Supported9 GE Healthcare VIVID Q Supported9 GE Vingmed VIVID E9 Supported9 GE Healthcare VIVID E90 Supported GE Healthcare VIVID E95 Supported GE Healthcare VIVID S70 Supported Hitachi Aloka Medical Avius Supported5, 9 Hitachi Aloka Medical EUB Hi VISION 5500 Supported5, 9
30
Hitachi Aloka Medical Hi VISION 900 Supported5, 9 Hitachi Aloka Medical Hi VISION Preirus Supported Hitachi Aloka Medical SSD-ALPHA 10SX Supported Hitachi Aloka Medical SSD-ALPHA5 Supported Hitachi Aloka Medical SSD-ALPHA6 Supported Hitachi Aloka Medical SSD-ALPHA7 Supported Hitachi Aloka Medical Arietta 60 Supported Hitachi Aloka Medical Arietta 70 Supported Hitachi Aloka Medical ProSound F75 Supported Hitachi Aloka Medical F37 Supported Hitachi Aloka Medical NOBLUS Supported KONICA MINOLTA HS1 Supported Mindray Medical M7 Supported5,9 Mindray Medical DC8 Exp Supported5,9 Mindray Medical TE7 Supported5,9 Mindray Medical M9 Supported5,9 Parks Medical Electronics Flo-Lab 2100SX (Sonova SW) Supported9 Parks Medical Electronics Flo-Lab 2100SX (SonovaE SW) Supported Parks Medical Electronics Flo-Lab 2100SX 2 (SonovaE SW) Supported Philips Affiniti Supported Philips iE33 Supported5 Philips iU22 Supported5, 19 Philips EPIQ5 Supported Philips EPIQ7 Supported Philips CX50 Supported Philips Sparq 2.0 Supported Samsung RS80 Supported Samsung WS80A Supported Samsung HM70A Supported Siemens G20 Supported5, 9 Siemens G50 Supported5, 9 Siemens G60S Supported5, 9 Siemens S1000 Supported Siemens S2000 Supported Siemens S3000 Supported Siemens SC2000 Supported Siemens Sequoia (v12.2) Supported5, 9 Siemens (Acuson) X300 Supported5, 9 SonoSite (FujiFilm) Edge Supported SonoSite Edge II Supported SonoSite M-Turbo Supported SonoSite MicroMAXX Supported SonoSite (FujiFilm) NanoMaxx Supported SonoSite Titan Supported SonoSite S-Series Supported SonoSite S II Supported SonoSite X-Porte Supported SuperSonic Imagine Aixplorer Supported Toshiba Aplio 80 Supported Toshiba Aplio 300 Supported Toshiba Aplio 400 Supported Toshiba Aplio 500 Supported Toshiba Aplio MX Supported
31
Toshiba Aplio XG Supported Toshiba Artida Supported Toshiba Nemio (SSA-550A) Supported Toshiba Nemio XG (SSA-580A) Supported Toshiba Viamo Supported Toshiba UltraExtend Supported1 Toshiba Xario Supported Toshiba Xario XG (SSA-680A) Supported Toshiba Xario 100/200 Supported Unetixs Unetixs Vascular MultiLab Series Supported Ultrasonix Medical Corp. SonicTOUCH Supported Ultrasonix Medical Corp. Sonix MDP Supported Ultrasonix Medical Corp. Sonix OP Supported Ultrasonix Medical Corp. Sonix RP Supported Ultrasonix Medical Corp. Sonix SP Supported Viasonix Falcon Supported Volcano S5 Supported9 Volcano S5i Supported5,9 Zonare Z.One Supported9 Zonare Z.OneUltra Supported9 Zonare ZS3 Supported Notes 1. No DICOM Modality Worklist capability. 5. Tested as DICOM Object. Test images were not converted to Targa format. 9. Automatic measurements may not be possible; manual calibration may be required. 17. DICOM Query/Retrieve – Study/Root Q/R fully supported. 19. Reported connectivity issues, please contact support for assistance
Visual Field Analyzer (Encapsulated PDF) Supported VL Visual Field Analyzer (Encapsulated PDF) Manufacturer Model Status Carl Zeiss Meditec, Inc. HFA 720-i Supported Carl Zeiss Meditec, Inc. HFA 740-i Supported Carl Zeiss Meditec, Inc. HFA 745-i Supported Carl Zeiss Meditec, Inc. HFA 750-i Supported Carl Zeiss Meditec, Inc. HFA II (Humphrey) Supported Carl Zeiss Meditec, Inc. HFA3 (with Forum) Supported Carl Zeiss Meditec, Inc. HFA3 Supported Carl Zeiss Meditec, Inc. HFA3 V1.3 Supported Carl Zeiss Meditec, Inc. Matrix 800 (HFA II) Supported Notes None
VL – Endoscopy Supported VL – Endoscopy Devices Manufacturer Model Status Endosoft (UTECH) Endosoft Systems Supported18 Endosoft (UTECH) Endosoft 6.0 (Platform: 6.0) Supported18 Endosoft (UTECH) EndoVault 1.3 (Platform: 6.0) Supported18 Endosoft EndoVault 2.15 and 3.0 Supported18 Envisionier Medical Technologies, Inc. eGoManager Supported Global Media Group, LLC CapSure 2.0 Supported5 Karl Storz AIDA HD Connect Supported Karl Storz OR1-AIDA Compact II Supported
32
Karl Storz StreamConnect NEO Supported1 KayPENTAX KDS (Digital Stroboscopy Workstation) Supported MedXchange DRSHD – Digital Recording System Supported MedXchange DRSHD – Digital Recording System v1.4 Supported Olympus EndoWorks Supported Olympus America, Inc. Endoworks 7,4 Supported STI UltraSight HD Supported Stryker Endoscopy SDC-HD Supported Stryker Endoscopy SDC Ultra Supported Stryker SDC3 Supported Notes 18 DICOM Encapsulated PDF.
VL – Pathology Supported VL –Pathology Devices Manufacturer Model Status Apollo Telemedicine ASAP Imaging Supported Notes None
Notes The notes below are included for reference purposes; see specific model listing for details.
1 No DICOM Modality Worklist capability. 2 Poor DICOM Modality Worklist capability. 3 Tested using the DeJarnette Netshare for interfacing. 4 Data transferred via an intermediary device. Confirm intermediary device was purchased as well. 5 Tested as DICOM Object. Test images were not converted to Targa format. 6 Obsolete; retained for numbering purposes. 7 Obsolete; retained for numbering purposes. 8 Only supplies Modality Worklist. 9 Automatic measurements may not be possible; manual calibration may be required. 10 Older versions of vendor’s software are not supported. 11 Obsolete; retained for numbering purposes. 12 Obsolete; retained for numbering purposes. 13 Obsolete; retained for numbering purposes. 14 Obsolete; retained for numbering purposes. 15 Does not support OP SOP Classes. 16 DICOM Query/Retrieve – Performs C-Find SCU and C-Move SCU roles only. 17 DICOM Query/Retrieve – Study/Root Q/R fully supported. 18 DICOM Encapsulated PDF. 19 Reported connectivity issues, please contact support for assistance 20 Version of DICOM Software approved on prior model 21 Requires using NNT/iRYS Workstation w/DICOM module