VIRCHOW PETROCHEMICAL PVT. LTD. SY.NO. 636 to 642, PEDDAPALLY VILLAGE,
JADCHERLA MANDAL, MAHABUBNAGAR DISTRICT, TELANGANA
FORM I
Project No. 1214‐21‐02December 2014
Virchow Petrochemical Pvt. Ltd. Sy. No. 17A, Phase – I , IDA, Patancheru, Medak District, Andhra Pradesh. Phone: 040‐30147102 Fax: 040‐30147126 E‐mail ID: [email protected]; [email protected]
STUDIES AND DOCUMENTATION BY TEAM Labs and Consultants B‐115‐117 & 509, Annapurna Block, Aditya Enclave, Ameerpet, Hyderabad‐500 038. Phone: 040‐23748 555/23748616, Telefax: 040‐23748666
SUBMITTED TO MINISTRY OF ENVIRONMENT AND FORESTS,
GOVERNMENT OF INDIA INDIRA PARYAVARAN BHAWAN, JOR BAGH ROAD, NEW DELHI
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 1
APPENDIX – I (See Paragraph – 6)
FORM I
I) Basic Information S.No.
Item Details 1
Name of the Project/s
Virchow Petrochemical Pvt. Ltd., 2
S. No in the Schedule
5 f – A category 3
Proposed capacity/area/length/tonnage to
be handled/command area/lease area/number of wells to be drilled
API’s (Synthetic Organic Chemicals). Capacity:
Phase I 500TPM Phase II
450TPM Total after Phase II
950TPM
Co‐generation Plant (Phase – II)
4MW Cost of the project: 150 Crores
4 New/Expansion/Modernization New 5
Existing Capacity/Area etc.
Not Applicable 6
Category of Project i.e. 'A' or 'B'
“A” 7
Does it attract the general condition? If yes,
please specify No
8
Does it attract the Specific condition? If yes, please specify.
No
9 Location
Plot/Survey/Khasra No.
Sy.No. 636 to 642 Village
Pedda pally(V), Pole Pally(Post)
Tehsil Jadcherla Mandal District
Mahabubnagar District State
Andhra Pradesh‐509302
10 Nearest railway station/airport
along with distance in kms.
Jadcherla(S.C Railways) 9 Km Rajivgandhi International Airport(Shamshabad)– 75 Km.
11 Nearest Town, City, District
Headquarters along with distance in kms.
Jadcherla– 6 Km
12 Village Panchayats, Zilla
Parishad, Municipal Corporation, Local
body (complete postal address with
telephone nos. to be given)
Pedda Pally‐ 1.5 KM
13 Name of the Applicant
Mr. M. Narayana Reddy 14
Registered Address M/s. Virchow Petrochemical
Pvt. Ltd.,
Plot No. 10, S.V.Co‐operative Industrial Estate, I.D.A Jeedimetla, Hyderabad‐500055.
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 2
15 Address for Correspondence:
Name
Mr. K. Nagendra Varma
Designation(Owner/Partner/CEO)
General Manager Address
Sy. No. 17A, Phase‐I, IDA,
Patancheru, Medak District.
Pin Code 502 319 E‐mail
[email protected]
[email protected] Telephone Number
040‐30147102 Fax No. 040‐30147126
16
Details of alternative Sites examined, if any. Location of these sites should be shown on a topo sheet.
‐NA‐
17 Interlinked Projects ‐NA‐ 18
Whether separate application of interlinked
project has been submitted? No
19 If yes, date of submission
20 If no, reason
21
Whether the proposal involves
approval/clearance under: if yes, details of the same and their status to be given.
(a) The Forest (Conservation) Act, 1980? (b) The Wildlife (Protection) Act, 1972? (c) The C.R.Z Notification, 1991?
‐NA‐
22 Whether there is any
Government Order/Policy relevant/relating to the site?
No
23 Forest land involved (hectares)
No 24
Whether there is any location pending
against the project and /or land in which the project is propose to be set up? (a) Name of the Court (b) Case No (c) Orders/directions of the Court, if any and its relevance with the proposed project.
No
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 3
(II) Activity
1. Construction, operation or
decommissioning of the Project
involving actions, which will
cause physical changes in the locality (topography, land use, changes in water bodies, etc.) S.No.
Information/Checklist confirmation Yes/No
Details thereof (with approximate quantities
/rates, wherever possible) with source of information data
1.1
Permanent or temporary change in land use, land cover or topography including increase in intensity of land use (with respect to local land use plan)
NO The proposal is
for a green
field project. The land area used
for the proposed plant
is 100.375acres. The land
is plain and does not involve much of leveling/excavation.
1.2
Clearance of existing land, vegetation and buildings?
NO The land area
is plain and
is not used for any agricultural activity
1.3 Creation of new land uses?
NO 1.4
Pre‐construction investigations e.g.
bore houses, soil testing? YES
Soil test done and soil load
bearing capacity
established. 1.5 Construction works?
NO Construction activity involves
plant
construction, erection only. 1.6
Demolition works? NO
1.7
Temporary sites used for construction works or housing of construction workers?
NO Construction labor from
local villages shall be employed.
1.8
Above ground buildings, structures orearthworks including linear structures, cut and fill or excavations
YES Office buildings, Production
blocks, Storage facilities for
raw material and final
products shall be constructed. No major cut and fill or excavation is anticipated.
1.9
Underground works including mining or tunneling?
NO
1.10 Reclamation works? NO
1.11 Dredging? NO 1.12
Offshore structures? NO 1.13
Production and manufacturing
processes? YES
Enclosed in Annexure – I
1.14
Facilities for storage of goods or materials?
NO Raw materials and solvents
shall be
stored with safety precautions.
1.15
Facilities for treatment or disposal of solid waste or liquid effluents?
YES Solid waste shall be
disposed to end users/recyclers or
sent to
incineration. Effluent generated from the plant are treated and reused. Details presented in Annexure II
1.16
Facilities for long term housing of operational workers?
NO
Local people shall be employed.
1.17
New road, rail or sea traffic during
YES
Construction materials shall be transported to
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 4
construction or operation? the site.
The traffic density of
the
existing connecting road is negligible.
1.18
New road, rail, air waterborne or other transport infrastructure including new or altered routes and stations, ports, airports etc?
NO
1.19
Closure or diversion of existing transport routes or infrastructure leading to changes in traffic movements?
NO
1.20
New or diverted transmission lines or pipelines?
NO
1.21
Impoundment, damming, culverting, realignment or other changes to the hydrology of watercourses or aquifers?
NO
1.22 Stream crossings? NO
1.23
Abstraction or transfers of water
form ground or surface waters? YES
Total water required shall be 706.9 KLD out of
which 493.9 KLD shall be drawn from bore well and the balance shall be recycled water.
1.24
Changes in water bodies or the land surface affecting drainage or run‐off?
NO
1.25
Transport of personnel or materials for construction, operation or decommissioning?
YES
The construction material shall be drawn from local sources within 10 – 15 km.
There is no transport of
personnel, as the
construction workers shall be drawn from local villages.
1.26
Long‐term dismantling or decommissioning or restoration works?
NO
1.27
Ongoing activity during decommissioning which could have an impact on the environment?
NO
1.28
Influx of people to an area in either temporarily or permanently?
YES The proposed project shall
increase
the employment potential and hence may lead to migration to surrounding villages.
1.29 Introduction of alien species?
NO 1.30
Loss of native species or genetic
diversity? NO
There are no major losses of tree/shrub
species. 1.31 Any other actions?
NO
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 5
2. Use of Natural resources for construction or operation of the Project (such as land, water, materials or energy, especially any resources which are non‐renewable or in short supply): S.No.
Information/checklist confirmation Yes/No
Details thereof (with approximate quantities
/rates, wherever possible) with source of information data
2.1
Land especially undeveloped or agricultural land (ha)
YES 100.375acres. Located
Sy.No. 636 to 642, Pedda pally Village, Pole Pally(Post), Jadcherla Mandal, Mahabubnagar
District, Andhra Pradesh.
2.2
Water (expected source & competing users) unit: KLD
YES
Total water required shall be 706.9 KLD out of which
493.9 KLD shall be drawn from
bore well and the balance shall be recycled water. (Water Balance Enclosed in Annexure III)
2.3 Minerals (MT) NA 2.4
Construction material – stone,
aggregates, sand / soil (expected source – MT)
YES
Shall be sourced from the local villages.
2.5
Forests and timber (source – MT)
NO 2.6
Energy including electricity and fuels
(source, competing users) Unit: fuel (MT), energy (MW)
YES The required energy shall
be drawn
from APTRANSCO. The power shall be drawn from existing
DG sets during load shut
downs. Backup DG sets of 2
x 1000 & 2 x 725
KVA after phase II shall be
provided to cater
to energy requirement during power shut downs period.
2.7
Any other natural resources (use appropriate standard units)
NA
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 6
3. Use, storage, transport,
handling or production of substances
or materials, which
could be harmful
to human health or
the environment or
raise concerns about
actual or perceived risks
to human health. S.No.
Information/Checklist confirmation Yes/No
Details thereof (with approximate
quantities/rates, wherever possible) with source of information data
3.1
Use of substances or materials, which are hazardous (as per MSIHC rules) to human health or the environment (flora, fauna, and water supplies)
YES Solvents shall be used
as reaction
media. MSIHC rules shall be followed during storage, transportation and handling of
raw materials and hazardous chemicals.
3.2
Changes in occurrence of disease or affect disease vectors (e.g. insect or water borne diseases).
NO
3.3
Affect the welfare of people e.g. by changing living conditions?
YES Shall increase the employment
potential for locals and affect
the living conditions
for betterment.
3.4
Vulnerable groups of people who could be affected by the project e.g. hospital patients, children, the elderly etc.,
NO No sensitive receptors are
present in the immediate vicinity
of the site. The project shall
not have any significant impact
on vulnerable groups of people.
3.5 Any other causes NO
4. Production of solid wastes during construction or operation or decommissioning (MT/month) S.No.
Information/Checklist confirmation Yes/No
Details thereof (with approximate
quantities/rates, wherever possible) with source of information data
4.1
Spoil, overburden or mine wastes NO
4.2
Municipal waste (domestic and or
commercial wastes) NO
Wastes from canteen, other
commercial
wastes like paper, empty containers etc. The canteen wastes
and commercial wastes
shall be in the range of 30 kg/day
4.3
Hazardous wastes (as per Hazardous Waste Management Rules)
YES The quantity of
hazardous wastes generated during
construction contains waste oils
and batteries from DG set.
The quantity of hazardous waste
generated during operation contain
salts from evaporators, stripper
distillate,
process residue, and solvent residues, ETP sludge and filtration media
etc. enclosed in Annexure
– IV
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 7
4.4 Other industrial process wastes
YES Enclosed at Annexure IV 4.5
Surplus product NO 4.6
Sewage sludge or other sludge from
effluent treatment YES
Sludge from Effluent treatment plant and
Salts from MEE & ATFD shall be sent to TSDF.
4.7 Construction or demolition wastes
NO
4.8 Redundant machinery or equipment
NO
4.9
Contaminated soils or other materials
NO
4.10 Agricultural wastes NO
4.11 Other solid wastes NO
Enclosed at Annexure IV
5. Release of pollutants or any hazardous, toxic or noxious substances to air (Kg/hr) S.No.
Information/Checklist confirmation Yes/No
Details thereof (with approximate
quantities/rates, wherever possible) with source of information data
5.1
Emissions from combustion of fossil fuels from stationary or mobile sources
YES
Coal Shall be used as fuel. Quantity of fuel and emissions details are enclosed in Annexure V
5.2
Emissions from production processes YES
Enclosed in Annexure ‐ VI 5.3
Emissions from materials handling
including storage or transport NO
Material transfer takes place in closed
pipeline systems. 5.4
Emissions from construction activities
including plant and equipment YES
Dust may rise during transport of material and
construction activity. The dust emissions shall be mitigated by water
spraying on the
roads within the premises.
5.5
Dust or odors from handling of materials including construction materials, sewage and waste
NO
5.6
Emissions from incineration of waste
NO 5.7
Emissions from burning of waste in
open air (e.g. slash materials, construction debris)
NO
5.8
Emissions from any other sources NO
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 8
6. Generation of Noise and Vibration, and Emissions of Light and Heat: S.No.
Information/Checklist
confirmation Yes/No
Details thereof (with approximate
quantities/rates, wherever possible) with source of information data with source of information data
6.1
From operation of equipment e.g. engines, ventilation plant, crushers
YES Material transport and
construction equipment shall be source
of noise, while transfer
pumps, vacuum systems, DG sets are the sources of noise during operation.
6.2
From industrial or similar processes
YES
From DG sets, and controlled by providing Acoustic Enclosures.
6.3 From construction or demolition
YES Noise during construction shall
be due
to construction equipment and emergency DG sets.
6.4 From blasting or piling NO
6.5
From construction or operational traffic
NO
The increased traffic shall not have any significant impact.
6.6
From lighting or cooling systems NO
6.7 From any other sources NO
7.Risks of contamination of land or water from releases of pollutants into the ground or into sewers, surface waters, groundwater, coastal waters or the sea: S.No.
Information/Checklist
confirmation Yes/No
Details thereof (with approximate
quantities/rates, wherever possible) with source of information data
7.1
From handling, storage, use or spillage of hazardous materials
NO All the hazardous materials
will be stored in Tanks/MS
drums, in a covered shed and
no contamination of soil is expected
7.2
From discharge of sewage or other effluents to water or the land (expected mode and place of discharge)
NO All the wastes
from domestic operations are
sent to septic tank followed by soak pit.
7.3
By deposition of pollutants emitted to air into the land or into water
NO Air Pollutants generated are
let out into atmosphere after
meeting the prescribed standards.
7.4 From any other sources NO
7.5
Is there a risk of long term build
up of pollutants in environment from these sources?
NO
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 9
8.Risk of accidents during construction or operation of the Project, which could affect human health or the environment S.No.
Information/Checklist confirmation Yes/No
Details thereof (with approximate
quantities/rates, wherever possible) with source of information data
8.1
From explosions, spillages, fires etc from storage, handling, use or production of hazardous substances
YES
All Inbuilt Safety precautions will be adopted
and there will not be
any damage to environment or
human health
8.2 From any other causes NA
8.3
Could the project be affected by natural
disasters causing environmental damage (e.g? Floods, earthquakes, landslides, cloudburst etc)?
NO
9.Factors which should be
considered (such as consequential
development) which could lead
to environmental effects or the
potential for cumulative impacts
with other existing or
planned activities in the locality S. No.
Information/Checklist confirmation Yes/No
Details thereof (with approximate
quantities/rates, wherever possible) with source of information data
9.1
Lead to development of supporting.
facilities, ancillary development or development stimulated by the project which could have impact on the environment e.g.: • Supporting infrastructure (roads, power supply, waste or waste water treatment, etc.)• housing development • extractive industries • supply industries • other
YES
The project shall enhance the socio economic
status of the area
by increasing the demand
for housing, improving the employment.
There are no major support
industries required for this plant.
9.2
Lead to after‐use of the site, which could haven impact on the environment
NO
9.3
Set a precedent for later developments
NO 9.4
Have cumulative effects due to proximity to
other existing or planned projects with similar effects
NO The baseline environmental
status of the surrounding areas
is within the prescribed limits
as
observed from the Secondary data.
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 10
(III) Environmental Sensitivity S.No.
Areas Name/
IdentityAerial distance (within 15 km.) Proposed project location boundary
1
Areas protected under international conventions, national or local legislation for their ecological, landscape, cultural or other related value
NA
2
Areas which are important or sensitive for ecological reasons ‐ Wetlands, watercourses or other water bodies, coastal zone, biospheres, mountains, forests
YES
Tigalapalli RF – 9Km – West Appannapalli RF – 9Km ‐ Southwest
3
Areas used by protected, important or sensitive species of flora or fauna for breeding, nesting, foraging, resting, over wintering, migration
NA
4
Inland, coastal, marine or underground waters
NO 5
State, National boundaries NO
6
Routes or facilities used by the public for access
to recreation or other tourist, pilgrim areas NO
7 Defense installations NO
8
Densely populated or built‐up area
YES Kaurapet is at
a distance of 7.4KM
in north‐eest with population
of 8000.
9
Areas occupied by sensitive man‐made land uses (hospitals, schools, places of worship, community facilities)
NA
10
Areas containing important, high quality or scarce resources (ground water resources, surface resources, forestry, agriculture, fisheries, tourism, minerals)
NO
11
Areas already subjected to pollution or environmental damage. (those where existing legal environmental standards are exceeded)
NO
12
Areas susceptible to natural hazard which could cause the project to present environmental problems (earthquakes, subsidence, landslides, erosion, flooding or extreme or adverse climatic conditions)
NO
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 11
(IV) Proposed Terms of Reference for EIA studies Scope of Work of EIA “...The EIA shall cover the following: Description of the proposed project: The
first task:” Description of the
proposed project” forms a vital
component of the Environmental Impact
Assessment (EIA) as it provides
the basis for evaluating the
likely causes of
Environmental Impacts.
Existing Environment and Baseline Conditions: The baseline assessment will be carried out to identify potentially sensitive and critical areas that may be affected by the project
in an area of 10 km surrounding the project
location.
The critical and sensitive targets shall be plotted on
land use map of project
impact area. The existing environment and baseline conditions should be established from:‐ Analysis of existing information published and secondary data. ‐Consultation with relevant statutory authorities, and Field visits for supplementation of missing gaps.
The key subject areas which the EIA shall address
include Ecology and Nature conservation, Air quality, surface and water quality in project impact area, soil quality, cultural heritage, landscape, land use, noise quality, etc.
Natural habitats
like national parks, wildlife reserves, sanctuaries, sacred grove, protected areas, forests, wetlands, major rivers and waterways if any, shall also be identified and marked.
Assessment of Environmental Impacts: Based
upon the results from the
review of existing information, field
visits, site data collection
and consultation, for each component of environment (physical, biological and socio economic) the positive, negative,
direct and indirect, temporary and
permanent impacts will be evaluated
along with
an indication of the degree of impact, i.e., whether the impact is significant, moderate, minor or negligible. The degree of impact shall also be quantified by using state of the art air quality impact prediction models based on ISCST3 algorithms.
Environment Management Plan And Mitigation Plan: For
each significant negative impact
identified, specialist shall work
closely with the
engineering team/technical consultants to
suggest practicable measures to avoid
or mitigate the impact.
The mitigation of environmental impacts will be by three mechanisms. =>Introduction of mitigation features through the engineering practices. =>Implementation of environmental controls during construction and operation. =>Legislative control involving compliance with Indian environmental laws. The Environmental management plan shall include an estimate of capital and recurring costs of mitigation measures and will identify the institutional framework for implementation.
Monitoring Plan: Having identified the significant environmental impact that is likely to arise as a result of the project, the project team shall specify what monitoring is required during the various phases of the project cycle. The monitoring plan will identify parameters and frequency of monitoring and responsible organization.
-
Virchow Petrochemical Pvt. Ltd.,
Form I
Page 12
I hereby give the undertaking that data and information given in the application and enclosures are true to
the best of my knowledge and belief and
I am aware that
if any part of the data and
information submitted is found
to be false or misleading at
any stage, the project will be
rejected and
clearance given, if any to the project will be revoked at our risk and cost.
Date:
Place:
Signature of the applicant With Name and Full Address
(Project Proponent/Authorized Signatory)
Mr. K. Nagendra Varma General Maager
M/s. Virchow Petrochemical
Pvt. Ltd., Sy. No. 17A, Phase‐I, IDA,
Patancheru, Medak District.
-
VIRCHOW PETROCHEMICAL PVT. LTD. SY.NO. 636 to 642, PEDDAPALLY VILLAGE,
JADCHERLA MANDAL, MAHABUBNAGAR DISTRICT, TELANGANA
ANNEXURES
SUBMITTED TO MINISTRY OF ENVIRONMENT AND FORESTS,
GOVERNMENT OF INDIA INDIRA PARYAVARAN BHAWAN, JOR BAGH ROAD, NEW DELHI
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 1
Loca
tion
Map
of
Vir
chow
Pet
roch
emic
al P
vt. L
td.,
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 2
TOTA
L AREA
: 1
00 A
CS
-15 G
TS
Kaurampet to Vollure Conncecting Road
Sy.
No.
633
GO
VT.
LAN
D
Gate
NH 7
(Hyder
abad -
Banga
lore)
Layo
ut o
f V
irch
ow P
etro
chem
ical
Pvt
. Ltd
.,
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 3
ANNEXURE - I
M/s. Virchow Petrochemical Pvt. Ltd., proposes to establish an
Active pharma
ingredient/synthetic organic chemical manufacturing unit at Sy.
No 636-642, Peddapally Village,
Jadcherla Mandal, Mahabubnagar District, Andhra Pradesh. The
project shall be established in
two phases. The first phase shall have manufacturing facility
for four products, while the second
phase shall has facility for five products along with 4 MW
co-generation plant. The land area
acquired for the proposed project is 100.375 acres. The capital
cost of the project is Rs. 150 crores.
The proposed list of products and manufacturing capacity is
presented in Table A-1 and list of by-
products is presented in Table A-2.
Table A-1 List of Products and Manufacturing Capacity
S.No Name of the Product CAS No. Capacity TPM Kg/day
PHASE - I 1 7-Phenylacetamido-3-Chloromethyl-Cephalosporanic
acid para-methoxybenzylester (GCLE) 104146-10-3 200 6666.67
2 Meta-Chloro Anisol 845-89-8 150 5000 3 Cefdinir 91832-40-5 50
1666.67 4 Cefixime 79350-37-1 100 3333.33 Total 500 16666.7 PHASE -
II
1 Aciclovir 59277-89-3 50 1666.67 2 Amoxicillin 26787-78-0 100
3333.33 3 Cephalexin 15686-71-2 100 3333.33 4 Ibuprofen 15687-27-1
100 3333.33 5 Tremadol Hydrogen Chloride 36282-47-0 100 3333.33
Total 450 15000
Total after Phase - II 950 31666.7 Co-generation Plant 4MW
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 4
Table A-2 List of By-Products
S.No Name of the Product Stage Name of the By-Product Capacity
Kg/day TPM
PHASE - I 1 7-Phenylacetamido-3-
Chloromethyl-Cephalosporanic acid para-methoxy benzylester
(GCLE)
I Potassium Chloride 1547 46.4 Spent HCl 5702 171
2 Meta-Chloro Anisol I Sodium Hydroxide (48%) 2924 87.7 3
Cefdinir I 2-mercapto benzothiazole 705 21.1 4 Cefixime I Tri
phenyl phosphine oxide 2260 67.8
II Phenyl Acetic Acid 937 28.1 III 2-mercapto benzothiazole
1228.8 36.9
PHASE - II 1 Aciclovir I Acetic Acid 998.3 29.9
III Di-methyl ammonium acetate
3112.1 93.4
2 Amoxicillin III Trimethylsilanol 821 24.6 Methyl acetoacetate
1059.1 31.8 Pivalic acid 930.5 27.9
3 Cefalexine III Pivalic acid 984.6 29.5 Ethyl aceto acetate
1123.9 33.7
4 Ibuprofen III Chromic sulfate 2114.3 63.4
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 5
Process Description of GCLE
Stage I:
1 3 8 ( P e n G K )
( W a t e r ) ( S - O x i d e )
( H y d r o g e n p e r o x i d e ) ( P - A n i s i c A l c o h
o l ) ( H y d r o c h l o r i c a c i d )
( P o t a s s i u m c h l o r i d e )
3 6 . 6
4 7 0 7 4 . 6 1 8
3 7 2 3 4
M e t h a n o lW a t e r
C 1 6 H 1 7 K N 2 O 4 S C 8 H 1 0 O 2 H C l H 2 O 2
C 2 4 H 2 6 N 2 O 6 S K C l 2 H 2 O
+ + +
+ +
Stage II:
( S - O x i d e )
( W a t e r )
( M B T ) ( B e n z e n e s u l f i n i c a c i d )
( S u l f o n e ) ( M B T )
C a t a l y s t N B A
D ST o l u e n eW a t e r4 7 0 1 6 7 1 4 2
5 9 4 1 6 7 1 8
H 2 O C 7 H 5 N S 2 C 3 0 H 3 0 N 2 O 7 S 2
C 7 H 5 N S 2 C 6 H 6 O 2 SC 2 4 H 2 6 N 2 O 6 S + +
++
Stage III:
(Sulfone) (Sodium bicarbonate)
(Chlorine) WaterMethanol
(Sodium methoxide)
84594 71 54
(GCLE) (Sodium Benzene sulfinate)
(Sodium chloride)
(Methanol)
32164 58.5486.5
C30H30N2O7S2 NaHCO3 Cl2 NaOCH3
C24H23N2O5SCl C6H5O2SNa NaCl CH3OH
+ ++
+ + + +
(Sodium ash)
106
Na2CO3 +
(Sodium bicarbonate)
84
NaHCO3
Process Description for Posaconazole:
Stage I: Penicillin G Potassium is reacted with p-Anisic
alcohol, Hydrochloric Acid and Hydrogen
peroxide in presence of Acetone, Methylene dichloride and
methanol to give p-methoxy benzyl 6-
phenacetamido penicillanate -1-oxide.
Stage II: P-methoxy benzyl 6-phenacetamido penicillanate
-1-oxide is reacted with 2-mercapto
benzothiazole and Benzene Sulphinic Acid in presence of NBA and
DS to form p-methoxy 2-
(benzene Sulphonyl thio)-α-(1-Methyl
ethyl-4-Oxo-3-phenacetamido-1-azetidine Acetate. The MLs
are further distilled to remove complete DS and water is added.
The mass is cooled and filtered to
get 2- mercapto benzothiazole for re-use.
Stage III: P-methoxy 2-(benzene Sulphonyl thio)-α-(1-Methyl
ethyl-4-Oxo-3-phenacetamido-1-
azetidine Acetate is reacted with sodium bicarbonate and
chlorine in presence of NBA and then
reacted with Sodium Methoxide to get p-methoxy
benzyl-7-phenacetamido-3-chloromethyl-3-
cephem-4-caroxylate(GCLE). The process flow diagram for GCLE is
presented in Fig A-1 and
material balance is presented in Table A-3.
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 6
Potassium chloride
Reaction & Distillation
(Stage‐I)
Penicillin G‐Potassium
P‐Anisic Alcohol
Hydrochloric acid (35%)
Acetone
M.D.C
Hydrogen peroxide
Acetone
Water
M.D.C
Methanol
Residue
S‐Oxide
Sodium Bisulfite
Water
Sodium bisulfite
Methanol
Stage I
Reaction & Distillation
(Stage‐II)Toluene
MBT
NBA
Catalyst
Water
Toluene
MBT
NBA
DS
SULFONE
Water
Residue
B.S.A (87%)
DS
Reaction & Distillation
(Stage‐III)
S.M.O
Sodium bicarbonate
Soda ash
Water
Methanol
Carbon dioxide
Sodium Benzene sulfinate
GCLE
Water
Residue
Chlorine
NBA
NBA
Sodium chloride
Methanol
S‐OxideStage II
Stage III
Fig A-1 Process Flow Diagram of GCLE
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 7
Table A-3 Material Balance for GCLE Stage I Input Quantity
(Kg/day) Output Quantity
(Kg/day) Remarks
Penicillin G-Potassium 9446.5 S-Oxide 11075.8 Stage I Product
P-Anisic Alcohol 3684.2 Potassium Chloride 1547 By-Product
Hydrochloric acid (35%) 6140.3 Potassium Chloride 211 To Wastewater
Hydrogen peroxide(50%) 1889 Water formed during
reaction 424.2 To Wastewater
Acetone 23616 Water formed during reaction
424.2 To By-Product (Spent HCl)
Methylene Dichloride (MDC)
37786 Acetone Recovery 23333 Recovered & reused
Water 23616 Acetone Loss 47 Fugitive Loss Sodium Bisulfite
151.14 Acetone to Residue 118 Solvent in Residue Methanol 28340
Acetone to
Wastewater 118 To Wastewater
MDC Recovery 36180 Recovered & reused MDC Loss 94 Fugitive
Loss MDC to Residue 378 Solvent in Residue MDC to Wastewater 1134
To Wastewater Methanol Recovery 27022 Recovered & reused
Methanol Loss 43 Fugitive Loss Methanol to Residue 1275 Solvent in
Residue Penicillin G-
Potassium 680.2 Organic Residue
P-Anisic Alcohol 432.1 Organic Residue Hydrochloric acid
(35%) 5277.8 By-Product (Spent
HCl) Hydrogen peroxide 143.4 To Wastewater Water 12280.5
Recovered & reused 12280.5 To Wastewater Sodium Bisulfite 151.1
To Wastewater Total Input 134670.1 Total Output 134669.8
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 8
Stage II Input Quantity
(Kg/day) Output Quantity
(Kg/day) Remarks
S-Oxide 11075.81 Sulfone 11187.2 Stage II Product 2-mercapto
benzothiazole 3876.5 2-mercapto
benzothiazole 2907.4 Recovered & reused
Benzene Sulfinic Acid (87%)
5537.9 2-mercapto benzothiazole
237.8 Organic Residue
N-Butyl Acetate (NBA) 44303 Water formed during reaction
339 To Wastewater
Catalyst 166.1 NBA Recovery 42531 Recovered & reused
Denatured Spirit (DS) 44303 NBA Loss 222 Fugitive Loss Water 5538
NBA to Residue 1329 Solvent in Residue Toluene 11076 NBA to
Wastewater 222 To Wastewater DS Recovery 42088 Recovered &
reused DS Loss 222 Fugitive Loss DS to Residue 1551 Solvent in
Residue DS to Wastewater 443 To Wastewater Toluene Recovery 10744
Recovered & reused Toluene Loss 33 Fugitive Loss Toluene to
Residue 244 Solvent in Residue Toluene to
Wastewater 55 To Wastewater
S-Oxide 2224 Organic Residue 2-mercapto
benzothiazole 731.3 Organic Residue
Benzene Sulfinic Acid (87%)
2143.6 Organic Residue
Water 3129 Recovered & reused 3129 To Wastewater Catalyst
166.1 Residue Total Input 125876.61 Total Output 125876.62
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 9
Stage III Input Quantity
(Kg/day) Output Quantity
(Kg/day) Remarks
Sulfone 11187.2 GCLE 6666.7 Final Product Sodium Bicarbonate
3468.0 Sodium Benzene
Sulfinate 2247.3 Organic Residue
Sodium Carbonate 2237.4 Sodium Bicarbonate 2302.2 Recovered
& reused Chlorine 1566.2 Sodium Methoxide(30%) 3468.0 Sodium
Chloride 801.6 To Wastewater N-Butyl Acetate (NBA) 44749 Methanol
438.5 Recovered & reused Methanol 33561 NBA Recovery 42959
Recovered & reused Water 10068 NBA Loss 224 Fugitive Loss NBA
to Residue 1298 Solvent in Residue NBA to Wastewater 268 To
Wastewater Methanol Recovery 32084 Recovered & reused Methanol
Loss 50 Fugitive Loss Methanol to Residue 1091 Solvent in Residue
Methanol to
Wastewater 336 To Wastewater
Methanol from Sodium Methoxide
2427.6 Recovered & reused
Sulfone 3047.4 Organic Residue Sodium Methoxide 300.4 Organic
Residue Chlorine in Sulfone
Complex 593.3 Organic Residue
Sodium Bicarbonate 2317 To Wastewater Sodium Carbonate 785 To
Wastewater Water 10068 To Wastewater Total Input 110305.34 Total
Output 110305.67
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 10
ANNEXURE – II: Wastewater Treatment Facilities
The effluent generated from the proposed M/s. Virchow
Petrochemical Pvt. Ltd., is mainly from
process, washings, scrubbers, cooling towers & boiler blow
downs and domestic effluent. Effluent
from process, washings and scrubbers are sent to Stripper,
Multiple Effect Evaporator followed by
ATFD and Biological treatment system and RO. Cooling towers
& boiler blow downs shall be
Biological treatment system followed by RO. RO permeate reused
for cooling towers and rejects
shall be sent to MEE. Domestic effluent shall be sent to sewage
treatment plant and treated effluent
shall be reused for gardening. Total Effluent generated after
Phase II and mode of treatment is
presented in Table A-4 and quantity and quality of effluent
generated from process is presented in
Table A-5.
Table A-4 Quantity of Effluent Generated
Description Quantity (KLD) Mode of Treatment Phase I Phase
II
HTDS Effluents Process 84.3 45 Treated in effluent treatment
plant consist
of Stripper, MEE, ATFD, Biological treatment and RO. RO permeate
reused for cooling tower makeup. RO rejects sent to MEE.
Washings 15 10 Scrubber Effluent 6 10
Total – I (HTDS) 105.3 65 LTDS Effluents
Boiler Blow downs 3 6.5 Sent to Biological Treatment System
followed by RO. RO permeate reused for cooling tower makeup. RO
rejects sent to MEE.
Cooling Tower Blow downs
12.5 31
Total - II (LTDS) 15.5 37.5 Domestic 8 8 Sent to Sewage
Treatment Plant and
treated effluent reused for gardening. Grand Total 128.8
110.5
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 11
Table A-5. Quantity and Quality of Effluent Generated from
Process S.No Name of the Product Kg/Day mg/l
Water Input
TDS COD Total Effluent
COD TDS
PHASE - I 1 GCLE 39222.7 4409 2810.4 33170.3 84737 132918 2
Meta-Chloro Anisol 11000 101.9 1.5 9583.9 158 10628 3 Cefdinir 5580
883.9 86.1 9203.7 9352 96037 4 Cefixime 26500 2406.1 813.3 32380.5
25117 74308 Total 82302.7 7800.9 3712 84338.8 44009 92494
PHASE - II 1 Aciclovir 5464.7 0 137.2 7405.8 18521 0 2
Amoxicillin 5199.9 625.8 19.8 6373.4 3112 98185 3 Cefalexine 186.1
56 3.9 773.8 4975 72362 4 Ibuprofen 14453 1390 150.5 16301.6 9229
85268 5 Tremadol Hydrogen
Chloride 10270 1121.6 294.7 14177.9 20786 79106
Total 35573.6 3193.3 606 45032.5 13457 70912 Total after Phase -
II 117876.3 10994.2 4317.7 129371.3 33374 84982
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 12
ANNEXURE – III: Water Balance
Water is required for process, scrubbers, washing, cooling tower
makeup, steam generation and
domestic purposes. The required water shall be drawn from ground
water sources in addition to
reuse of treated wastewater. It is proposed to provide storm
water storage tank of 15000 KL
capacity, which shall meet the plant water requirement for at
least 100 days. The total water
requirement after phase II is in the order of 706.9 KLD
consisting of 493.9 KLD fresh water and 213
KLD of recycled water. The fresh water requirement for Phase I
is 213.3 KLD and 280.6 KLD for
Phase II and treated wastewater reuse for Phase I is 115 KLD and
98 KLD for Phase II. The water
balance for daily consumption after Phase II is presented in
Table A-6.
Table A-6 Total Water Balance
Purpose INPUT (KLD) OUTPUT (KLD) Fresh Water Recycled Water Loss
Effluent
Phase I
Phase II
Phase I
Phase II
Phase I
Phase II
Phase I
Phase II
Process 82.3 35.6 84.3* 45* Washings 5 5 10 5 15 10 Scrubber 6
10 6 10 Boiler Feed 30 130 10 37 123.5 3 6.5 Cooling Tower 20 90 87
85 94.5 144 12.5 31 Domestic 10 10 2 2 8 8 Gardening 60 8 8 68 8
Gross Total 213.3 280.6 115 98 201.5 277.5 128.8 110.5 Total 493.9
213 479 239.4
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 13
ANNEXURE – IV: Solid Waste
Solid wastes are generated from the process shall be sent to
TSDF/ Cement Industries for Co-
incineration. The inorganic residue, evaporation salts from MEE
and ATFD and ETP Sludge shall
be sent to TSDF. The list of solid wastes generated from the
process is presented in Table A-7 and
total solid waste generated and mode of disposal is presented in
Table A-8.
Table A-7 Solid Waste Generated from Process
S.No Name of the Product
Quantity (Kg/Day) Process Organic Residue
Process Inorganic Residue
Solvent Residue
Spent Carbon
Catalyst Total
PHASE - I 1 GCLE 12637.4 0 7283.1 166.1 20086.6 2
Meta-Chloro
Anisol 286.6 2982.5 122 3391
3 Cefdinir 1126.3 0 79 1205.3 4 Cefixime 3634 429.9 667.3 4731.2
Total 17684.4 3412.4 8111.3 0 166.1 29374.2
PHASE - II 1 Aciclovir 856.1 0.0 269.3 12.0 3.0 1140.4 2
Amoxicillin 1290.2 769.3 242.2 2301.8 3 Cefalexine 2319.4 1334.4
504.4 4158.2 4 Ibuprofen 2420.5 1747.1 529.3 103.2 4800.1 5
Tremadol HCl 640.9 1057.3 254.4 1952.6 Total 7527.2 4908.1 1799.5
12.0 106.2 14353
Total after Phase - II 25211.5 8320.5 9910.8 12.0 272.3
43272.2
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 14
Table A-8 Total Solid Waste Generated and Mode of Disposal
S.No Description Units Phase I
Phase II
Mode of Disposal
1 Ash from Boiler TPD 13 32.6 Sold to Brick manufactures 2
Process Organic
residue TPD 17.68 7.5 Sent to TSDF/Cement Industries
3 Solvent Residue TPD 8.1 1.8 Sent to TSDF/Cement Industries 4
Spent Carbon Kg/day --- 12 Sent to TSDF/Cement Industries 5 Process
Inorganic
Residue TPD 3.4 4.9 Sent to TSDF
6 Mixed Solvents KLD 90.5 24.2 Sent to authorized recovery
units/Cement plants for co-incineration
7 Spent Solvents KLD 211.2 56.5 Recovered within the plant
premises.
8 Evaporation Salts TPD 7.8 6.9 Sent to TSDF 9 Stripper
Distillate KLD 4.97 2.75 Sent to Cement Industries for
Co-incineration. 10 Catalyst TPD 0.2 0.1 Returned to
manufacturer 11 ETP Sludge TPD 2.2 0.5 Sent to TSDF 12 STP Sludge
Kg/day 0.4 0.4 Sent to TSDF 13 Detoxified containers No.s/year 400
600 After detoxification sent to
Authorized agencies 14 Waste oil Kl/Month 2 2 Sent to Authorized
Recyclers 15 Used batteries No.s/year 10 10 Sent to Authorized
Recyclers
-
Virchow Petrochemical Pvt. Ltd., Form I Annexures
Page 15
ANNEXURE – V: Stack Emissions Details
The sources of air pollution from the plant are 12TPH and 30TPH
coal fired Boilers and DG set of
1000 & 725 KVA capacity each in Phase I and Phase II
respectively. The proposed air pollution
control equipment for coal fired boilers is bag filter and ESP
for 12 and 30 TPH boilers
respectively. DG sets shall be provided with stack heights based
on the CPCB formula for effective
stack height. The emission rates of SPM, SO2, NOx and SPM from
each stack are presented in
Table A-9.
Table A-9 Stack Emission Details
S. No
Stack Connected to Stack Ht (m)
Dia of stack
at top(m)
Temp. of
exhaust gases (OC)
Exit Velocity (m/sec)
Pollutant Emission Rate (g/sec)
SPM SO2 NOx
Phase - I 1 12TPH Coal fired Boilers 32 1 180 10 0.36 0.5 1.0 2
1000KVA DG Set 10 0.15 151 10 0.01 0.02 0.03 3 725KVA DG Set 6 0.8
140 8 0.010 0.015 0.020
Phase - II 1 30TPH Coal fired Boilers 42 2 200 15 2.5 4.5 5.1 2
1000KVA DG Set 10 0.15 151 10 0.01 0.02 0.03 3 725KVA DG Set 6 0.8
140 8 0.010 0.015 0.020
*DG sets will be used during load shut down by APTRANSCO.
Table A-10 Process Emission
S.No
Name of the Product
Stage Name of the Gas
Quantity (Kg/day)
Mode of Disposal
PHASE - I 1 Cefdinir I Carbon dioxide 185.5 Let out into
atmosphere safely 2 Cefixime I Carbon dioxide 336.8 Let out into
atmosphere safely
PHASE - II 1 Amoxicillin II Ammonia 175.5 To Scrubber 2
Cefalexine II Ammonia 175.6 To Scrubber 3 Ibuprofen I Hydrogen
Chloride 817.1 To Scrubber
II Carbon dioxide 787.6 Let out into atmosphere safely II
Hydrogen 17.9 Let into atmosphere safely
through water column
-
VIRCHOW PETROCHEMICAL PVT. LTD. SY.NO. 636 to 642, PEDDAPALLY VILLAGE,
JADCHERLA MANDAL, MAHABUBNAGAR DISTRICT, TELANGANA
STUDIES AND DOCUMENTATION BY TEAM Labs and Consultants QCI:
MoE&F OM, List A-1, S.No. 150. (An ISO 9001:2008, ISO
14001:2004 & OHSAS 18001:2007 Certified Organization) B-115,
Annapurna Block, Aditya Enclave Ameerpet, Hyderabad-500 038. Phone:
040-23748 555/616, Telefax: 040-23748666 Email:
[email protected]