VIDAS ® ANTI-MÜLLERIAN HORMONE On-hand testing for greater patient comfort PIONEERING DIAGNOSTICS BIOMÉRIEUX
3

VIDAS ANTI˜MÜLLERIAN HORMONE - biomerieux-diagnostics.com · LH (mIU/mL) AMH (ng/mL) Days FSH (mIU/mL) Sensitive to conformational change in samples (5) More accurate than Antral

Aug 29, 2019

Download

Documents

truongthuan
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: VIDAS ANTI˜MÜLLERIAN HORMONE - biomerieux-diagnostics.com · LH (mIU/mL) AMH (ng/mL) Days FSH (mIU/mL) Sensitive to conformational change in samples (5) More accurate than Antral

VIDAS®

ANTI-MÜLLERIAN HORMONEOn-hand testing for greater patient comfort

PIONEERING DIAGNOSTICS

BIOMÉRIEUX

Page 2: VIDAS ANTI˜MÜLLERIAN HORMONE - biomerieux-diagnostics.com · LH (mIU/mL) AMH (ng/mL) Days FSH (mIU/mL) Sensitive to conformational change in samples (5) More accurate than Antral

Did you know?1/6 couples worldwide experience some form of infertility (1)

Polycystic Ovary Syndrome (PCOS) a� ects 5-10% of women

of reproductive age (2)

In 30 years, the success rate of IVF has increased

from 10% to above 30% (3)

VIDAS®

Anti-Müllerian HormoneOn-hand testing for greater patient comfort

Reliability and robustness

* See package insert

VIDAS®: an easy-to-usebenchtop platform

Greater reliability through patented proprietary raw materials ➔ Reliable results when compared with an existing automated method* ➔ Minimal impact of pre-analytical stage on test results:

1 patient = 1 test for maximum � exibility

Anti-Müllerian Hormone (AMH) testingfor ovarian function assessment in women

CLINICAL APPLICATIONS As an indicator of the ovarian follicle reserve, AMH is useful in di� erent contexts all along the reproductive lifespan: Personalization of infertility management (IVF/ART): Assessment of ovarian reserve for infertility investigations Help to select the best stimulation protocol ➔ Adapt treatment ➔ Avoid unnecessary stimulation ➔ Reduce risk of hyperstimulation syndrome

Detection of ovarian dysfunction (PCOS, Premature ovarian failure…):The use of AMH rather than Follicle Stimulating Hormone (FSH) or Luteinizing Hormone (LH) provides direct, more accurate assessment of ovulation.Monitoring of ovarian damage(surgery, gonadotoxic therapies) First-choice marker to detect the decline of the ovarian reserve.

≤ 8 hours at +18/+25°C in closed primary tube

≤ 5 days at +2/+8°C when aliquoted

≤ 3 freezing-thawing cycles

≤ 3 cycles≤ 8 hours ≤ 5 days

❄ ❄ ❄

● Just load & go● Limited calibration and maintenance● Compact instrument: easily � ts into your fertility center

or laboratory

00-2-4-6-8-10-12-14 2 4 6 8 10 12 14

5

10

15

20

25

30

35

0

1

2

3

4

5

6

LH (mIU/mL) AMH (ng/mL)

Days

FSH (mIU/mL)

Sensitive to conformational change in samples (5)

More accurate than Antral Follicular Count (AFC)● Inter-operator variation makes AFC subjective● AMH provides quantitative objective results (6)

A key test within the diagnostic work-up

Circulatory patterns of FSH, LH and AMH during the menstrual cycle of young healthy women (4)Day 0 = day of LH surge

AMH FEATURES Stable over the menstrual cycle

24/7 availability for your patients’ comfort

VIDAS® COMMUNITY:partnering over

30 000 usersworldwide

A COMPLETE SOLUTION ON YOUR VIDAS® INSTRUMENT

SEROLOGYPANELS HEPATITIS HIV TORC

HORMONEASSAYS

AMH ESTRADIOL FSH LH HCG PROLACTIN PROGESTERONE TESTOSTERONE THYROID PANEL

● On-demand testing● Results during the consultation ➔ Less patient stress ➔ Immediate integration of AMH results

into the full diagnostic work-up ➔ Treatment optimization ➔ No unnecessary ovarian stimulation

Page 3: VIDAS ANTI˜MÜLLERIAN HORMONE - biomerieux-diagnostics.com · LH (mIU/mL) AMH (ng/mL) Days FSH (mIU/mL) Sensitive to conformational change in samples (5) More accurate than Antral

bioMérieux S.A. • 69280 Marcy l’Etoile • France • Tel.: + 33 (0)4 78 87 20 00 • Fax: +33 (0)4 78 87 20 90www.biomerieux.com • www.biomerieux-diagnostics.com-

AVAILABLE ONVIDAS® INSTRUMENTS:VIDAS®, MINI VIDAS® AND VIDAS® 3

Reference number 417011

Tests / kit 30

Time to result 35 min

Sample type Serum, Plasma (Li Hep)

Sample volume 200 µL

Units ng/mL - pmol/L

Measuring range 0.02 – 9.00 ng/mL

Calibrators & Controls frequency 28 days

VIDAS® AMH

VIDAS® o� ers your lab simplicity and productivity. It will enhance your work� ow, thanks to its six independent compartments.

REFERENCES1. https://www.eshre.eu/Guidelines-and-legal/ART-fact-sheet2. https://www.pcosfoundation.org/3. https://www.sart.org/History_of_IVF/4. La Marca et al Human Reproduction 20065. Rustamov O et al Human Reproduction 20126. Anderson RA et al Fertility and Sterility 2015

05-1

8/ 9

3125

55/0

08/G

B/A

/ Do

cum

ent a

nd/o

r pic

ture

s no

t leg

ally

bin

ding

. Mod

i� ca

tions

by

bioM

érie

ux c

an b

e m

ade

with

out p

rior n

otic

e /

BIO

MÉR

IEU

X,

the

BIO

MÉR

IEU

X lo

go a

nd V

IDAS

are

use

d, p

endi

ng a

nd/o

r reg

iste

red

trad

emar

ks b

elon

ging

to b

ioM

érie

ux, o

r one

of i

ts s

ubsi

diar

ies

or o

ne o

f its

com

pani

es.

Any

othe

r tra

dem

ark

is th

e pr

oper

ty o

f its

resp

ectiv

e ow

ner.

/ bi

oMér

ieux

S.A

. RCS

Lyon

673

620

399

/ P

rinte

d in

Fra

nce

/ th

era/

RCS

Lyon

B 3

98 16

0 24

2

BIOMÉRIEUX