When every minute counts, choose the solution that makes a difference. VICTAULIC • PIPING SOLUTIONS FOR DATA CENTER FACILITIES
Jun 25, 2015
When every minute counts, choose the solution that makes a difference.
V I C T A U L I C • P I P I N G S O L U T I O N S F O R D A T A C E N T E R F A C I L I T I E S
2 Data Centers www.victaulic.com
As the world leader in mechanical piping systems, Victaulic has set the global standard for piping efficiency, engineering expertise and performance reliability by protecting, heating and cooling buildings all over the world.
Hoover Dam - United States
• Supplies 16 million people with water every day
• Generates 4 billion kilowatt hours of hydroelectric energy annually
• Outfitted with Victaulic mechanical piping products because they installed quickly and easily with only minimal service disruptions
From performing under pressure in the Hoover Dam to protecting ancient treasures in Egypt, Victaulic has been trusted for 85 years to provide quality products that meet the most demanding industry challenges.
Alexandria Library - Egypt
• Home to priceless ancient artifacts from around the world
• The Library required unparalleled piping system reliability
• Victaulic products for both HVAC and Fire Protection systems were trusted throughout the building
Victaulic PIPING. SYSTEMS. SOLUTIONS.
2 Data Centers2 Data Centers
Trust Victaulic to protect and cool your mission critical facilities.
As more and more data centers transition to water systems as the most efficient method of cooling - 4,000 times more efficient than air - owners and engineers demand only the most reliable piping systems are used in their facilities.
Whether cooling, heating or protecting your data center facility, Victaulic has the products and solutions to get your data center up and running quickly and operating efficiently.
Data Centers 3 Data Centers 3
4 Data Centers www.victaulic.com
Compressed Project Schedules
3
1
2
6
5
4
9
10
11
8
7
12
MAN
HOU
RS P
ER J
OIN
T
PIPE SIZE
Grooved
Welded
Flanged
2" 4" 6" 8" 10" 12"
Quicker, easier installations3 TO 5 TIMES FASTER TO INSTALL
Victaulic mechanical piping systems are three to five times faster to install than traditional joining methods. Meet and exceed the “flash-track” schedules associated with data center construction.
Victaulic benefits that save you time and valuable resources.
IMPROVED SAFETYNo flame joining method
LABOR SAVINGSEasier maintenance and system expansion
DESIGN VERSATILITYMore options and easily accomodates system change
4 Data Centers4 Data Centers
Welded systems demand 45% more man-hours on average compared to Victaulic no-flame piping solutions.
The math is simple: less man-hours equals less exposure and project risk.
NU
MBE
R OF
MEN
ON
SIT
E
MECHANICAL CONSTRUCTION WEEKS
Shift Maximum Manpower Line
Meet or Beat Project Schedule
Victaulic Peak Man-Power
Welded Peak Man-Power
Victaulic will increase project efficiency and reduce field man-hours from start to finish with value added services.
VICTAULIC SERVICES INCLUDE:
• Estimating
• Pre-Planning and Project Management
• Jobsite Training
• Software Solutions
Data Centers 5 Data Centers 5
6 Data Centers www.victaulic.com
Seismic Performance TestingNatural disasters happen, but when there is no time for downtime, planning ahead can make a world of difference.
Piping systems located in earthquake prone areas are likely to be exposed to forces and deflections beyond normal static conditions and the results can be catastrophic.
Victaulic components can accommodate seismic forces in the following piping system conditions.
• Code-regulated systems with adequate earthquake bracing
• Unregulated systems with little or no earthquake bracing
• Seismic joint connections between independently-moving sections
• Buried systems
Seismic swing joint utilizing Victaulic mechanical piping components
6 Data Centers6 Data Centers
Testing performed at the Real-Time Multi-directional Experimental Laboratory at the Center for Advanced Technology for Large Structural Systems at Lehigh University in Bethlehem, PA, USA proved the suitability of Victaulic grooved mechanical couplings to maintain operational integrity of piping systems during seismic events.
Victaulic couplings ranging in size from 4”-16”/100 - 400 mm were exposed to accelerations up to 50% greater than the Northridge, California earthquake. The water-filled assemblies were pressurized to 200psi/1375 kPa for the duration of all tests and no pressure loss or leakage was noted during any of the tests.
Data Centers 7 Data Centers 7
8 Data Centers www.victaulic.com
The versatility, reliability and speed of Victaulic mechanical pipe joining systems makes them ideal for use in data center applications.
By specifying and installing Victaulic, engineers, owners and installation contractors conserve time and financial resources through:
COMPRESSED PROJECT SCHEDULES Victaulic systems increase project efficiency from the start
LOWERED TOTAL INSTALLED COST Over the lifetime of the system
SAFER WORK ENVIRONMENT Reduced calendar days reduces exposure to job site accidents
REDUCED SYSTEM DOWNTIME during scheduled maintenance and service checks
Anatomy of a Grooved Joint
8 Data Centers8 Data Centers
A UNION AT EVERY JOINTRemoval of two couplings permits removal of a pipe section for replacement, cleaning or servicing.
MAINTAINABILITY Victaulic systems provide easy accessibility when conducting preventative systems maintenance, resulting in a continued high level of energy efficiency and little to no downtime required.
Maintenance plans are a critical element to every data center. Whether maintaining computer equipment or cooling equipment, system shut downs are limited to mere minutes. By using Victaulic mechanical piping systems, changing out inefficient equipment is as easy as loosening two bolts and two nuts. There is no need and no time required to cut out sections of pipe and re-weld.
Exaggerated for clarity
VALUE ADDED ENGINEERING
At the root of all the benefits that Victaulic solutions bring to a project - such as jobsite productivity, safety, design flexibility and quality - are the unique features of its products.
Roll Grooving
Expansion & Contraction
Coupling Assembly
Deflection Capabilities
Contraction
Expansion
De�ection
Contraction
Expansion
De�ection
Data Centers 9 Data Centers 9
10 Data Centers www.victaulic.com
Data Center Mechanical Room
Condenser Water Units
To get your data center up and running quickly, Victaulic offers a full line of couplings, fittings, valves and accessories for use throughout a facility’s mechanical room.
1ST FLOOR MECHANICAL ROOM
Mechanical Room Piping
End Suction Pumps
10 Data Centers10 Data Centers
Chillers
Horizontal Split Case Pump
From pumps and chillers to air handling units and cooling towers, Victaulic mechanical piping systems provide a fast, safe, reliable connection ideal for data center applications.
Data Centers 11 Data Centers 11
12 Data Centers www.victaulic.com
Data Center Distribution Piping
DN
.
DN
.
DN.
CH
ASE
MECH.CHASE
MECH.CHASE
FM-2
00 C
HAS
E BE
LOW
ELECT. CHASE BELOW
1'-111516"
BOM 7
BOM 9
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit CRAC Unit
CRAC Unit CRAC Unit
CRAC Unit CRAC Unit CRAC Unit CRAC Unit
CRAC Unit
CRAC Unit
Future CRAC Unit
CRAC Unit CRAC Unit CRAC Unit CRAC Unit CRAC Unit CRAC Unit
CRAC Unit
CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Futu
re C
RAC
Uni
tFu
ture
CRA
C U
nit
Futu
re C
RAC
Uni
t
Futu
re C
RAC
Uni
tFu
ture
CRA
C U
nit
CRAC Unit
Victaulic products are ideal for use in data center distribution piping because they install quickly and easily, provide a safe, reliable pipe connection and easily accommodates tight space constraints.
2ND FLOOR DATA CENTER
Victaulic couplings and fittings are ideal for use in tight spaces
Victaulic rigid couplings for straight runs of pipe
Branch connections made easy using Victaulic products
12 Data Centers12 Data Centers
DN
.
DN
.
DN.
CH
ASE
MECH.CHASE
MECH.CHASE
FM-2
00 C
HAS
E BE
LOW
ELECT. CHASE BELOW
1'-111516"
BOM 7
BOM 9
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit
CRAC Unit CRAC Unit
CRAC Unit CRAC Unit
CRAC Unit CRAC Unit CRAC Unit CRAC Unit
CRAC Unit
CRAC Unit
Future CRAC Unit
CRAC Unit CRAC Unit CRAC Unit CRAC Unit CRAC Unit CRAC Unit
CRAC Unit
CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Future CRAC Unit
Futu
re C
RAC
Uni
tFu
ture
CRA
C U
nit
Futu
re C
RAC
Uni
t
Futu
re C
RAC
Uni
tFu
ture
CRA
C U
nit
CRAC Unit
Victaulic butterfly valves for dead-end shutoff
Victaulic offers a full line of piping systems components
Victaulic couplings and elbows
Mechanical Room Connection to Second Floor Distribution Piping (Under-floor piping)
Data Centers 13 Data Centers 13
14 Data Centers www.victaulic.com
VictaulicVortex™ Fire SuppressionProtecting Equipment, Personnel and the Environment
Until now, fire suppression meant damaged equipment, lengthy and costly clean up, and lost productivity.
Now, data center owners can breathe a little easier knowing their equipment and environment are protected by the VictaulicVortex Fire Suppression System.
VictaulicVortex • The only hybrid nitrogen-water fire
suppression system
• Nearly ZERO wetting of protected areas
• No ozone depleting or greenhouse gas emissions
• Quick system recharge to support minimal facility downtime
“ My clients were very impressed with the VictaulicVortex system when they saw the level of fire protection it provides without huge amounts of water or toxic chemicals. It’s all about protecting the people and assets, minimal impact on the hazard environment and the fast return to normal operations.
The Vortex system delivers.”
TOM EUSON, 3S INCORPORATED
Made entirely of non-toxic agents — personnel are safe even during activation; reduction of oxygen in the space is at levels within safe breathing tolerances.
System activation is immediate when sensors detect smoke or heat — there is no delay in activation to evacuate personnel to avoid a toxic environment.
14 Data Centers14 Data Centers
VictaulicVortex in a Data Center
The system fully extinguishes fires in enclosed cabinets and isolated equipment within protected spaces.
Zones can be centrally controlled yet independently activated for fire suppression only where required.
The system delivers as little as one gallon of water per emitter per minute: each emitter can protect up to 2,500 cubic ft.
The system is compatible with facility fire protection systems providing greater design flexibility.
System is recharged rapidly allowing for a return to working conditions almost immediately after a fire.
Data Centers 15 Data Centers 15
16 Data Centers www.victaulic.com
Global Data Center Project SuccessesFrom the United States to Singapore, Victaulic mechanical piping systems are trusted all over the world to protect, heat and cool data centers.
16 Data Centers16 Data Centers
Data Centers 17 Data Centers 17
18 Data Centers www.victaulic.com
Global Data Center Project Successes
18 Data Centers18 Data Centers
Data Centers 19 Data Centers 19
Saved: October 28-2008 - 10:37 (+00 GMT)
User: Brian Conway-Smith
File: /Volumes/Current Work/• Victaulic Reference/Victaulic logo - Black & PANTONE NEW.aiDocument: Victaulic logo - Black#2F943.ai
www.victaulic.com
The Victaulic website is an information resource that can help you with your piping projects. Among the many resources available at the site:
• Fully searchable product and project databases • Free product submittals • Free product literature • Piping software demos, modules and downloads. • Information on new product innovations • Support services, and more...
VICTAULIC LOCATIONS
MB-110 5442 Rev.C
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
VICTAULIC GLOBAL CONTACT INFORMATION
US & WORLD HEADQUARTERS
P.O. Box 31Easton, PA 18044-0031 USA
4901 Kesslersville RoadEaston, PA 18040 USA 1-800-PICK-VIC (1-800-742-5842) 1-610-559-3300 1-610-250-8817 (fax) [email protected]
www.victaulic.com
UNITED KINGDOM
Units B1 & B2, SG1 Industrial ParkCockerell CloseGunnels Wood RoadStevenageHertfordshire, SG1 2NB (UK)+44 (0) 1438 310 690+44 (0) 1438 310 699 (fax)
CENTRAL AND SOUTH AMERICA
P.O. Box 31Easton, PA 18044-0031 USA
4901 Kesslersville RoadEaston, PA 18040 USA
1-610-559-33001-610-559-3608 (fax)[email protected]
ASIA PACIFIC
3A/F, A Mansion, No. 291 Fumin Road, Shanghai 200031, China +86 21 6170 1222+86 21 6170 1221 (fax)[email protected]
MIDDLE EAST
P.O. Box 17683Unit XB 8Jebel Ali Free ZoneDubai United Arab Emirates971-4-883-88-70971-4-883-88-60 (fax)
CANADA
123 Newkirk RoadRichmond Hill, ON L4C 3G5905-884-7444905-884-9774 (fax)[email protected]
EUROPE
Prijkelstraat 369810 Nazareth, Belgium32-9-381-15-0032-9-380-44-38 (fax)[email protected]
ENGLISH