Top Banner
Vertical Emittance Measurement with a Vertical Undulator Mark Boland Australian Synchrotron University of Melbourne On behalf of Kent Wootton University of Melbourne Oxford, 10 July 2013 Low Emittance Ring Workshop
11

Vertical Emittance Measurement with a Vertical Undulator

Jan 01, 2016

Download

Documents

amanda-conway

Vertical Emittance Measurement with a Vertical Undulator. Mark Boland Australian Synchrotron University of Melbourne On behalf of Kent Wootton University of Melbourne. Oxford, 10 July 2013 Low Emittance Ring Workshop. Abstract. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Vertical Emittance Measurement with a Vertical Undulator

Vertical Emittance Measurement with a Vertical Undulator

Mark BolandAustralian SynchrotronUniversity of Melbourne

On behalf of

Kent WoottonUniversity of Melbourne

Oxford, 10 July 2013Low Emittance Ring Workshop

Page 2: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 2

Abstract• Method developed to measure the vertical emittance in a storage

ring using a vertical undulator. (K. P. Wootton, M. J. Boland, et al. (2012). "Observation of Picometer Vertical Emittance

with a Vertical Undulator." Physical Review Letters 109(19): 194801.)

• Measure the ratio of the odd and even harmonic peaks.• Observed ultra low vertical emittance on SLSA storage ring.• Characterised the undulator radiation and got good agreement

with calculated radiation using measured magnetic field maps.• Improved sensitivity by scanning the e-beam and collect statistics• Planned improvements by measuring the photon polarisation.

10 July 2013

Page 3: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 3

Overview of the Method• APPLE II undulator on the Soft X-ray

beamline at the Australian Synchrotron(B. C. Cowie, A. Tadich, and L. Thomsen, AIP Conf. Proc.

1234, 307 (2010).)

• Phase the magnets to vertical polarisation

10 July 2013

Page 4: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 4

Spectral Measurement Results

10 July 2013

Page 5: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 5

Cross Check with X-ray Pinhole Camera

10 July 2013

Page 6: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 6

Sensitivity to Pinhole Size and Beam Decay

10 July 2013

Page 7: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 7

Undulator Characterisation

• Blade scans to observe vertical distribution

• Asymmetry observe between the top and bottom peak

• Comparison with SPECTRA simulations of 2D radiation

• SPECTRA tracks of e-beam through measured magnetic field also produce assymetry

10 July 2013

Page 8: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 8

New Approach

10 July 2013

• Time averaging• Normalise to beam current

due to 1 hour lifetime at minimised emittance

• Beam bumps instead of blade scans

• Electron beam Orbit bumps through the undulator

• Parallel position bump and vertical angle bumps

Angle scan of the e-beam through the undulator for three different harmonics (red odd, blue even, black odd)

Page 9: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 9

Measurement of Latest Emittance Minimisation

• Not sensitive enough to sub pm emittance

• Need to separate p and s modes in the photon beam

• 2D x-ray pixel detector may also help resolve ultra low emttances

10 July 2013

Page 10: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 10

Polarisation Simulations

• Improved sensitivity with selection of only vertical photon polarisation

• Acknowledgement of Spring-8 Takano work

10 July 2013

S. Takano, EMIT’ 97, KEK Proceedings 97-20 (1997)

Page 11: Vertical Emittance Measurement with a Vertical Undulator

LER 2013, Oxford - Mark Boland 11

Conclusions/further work

• Not sensitive enough for sub pm emittance• Planning polarisation measurements• Seeking interested collaborators (with 2D x-ray detectors?)

10 July 2013