Vertical Emittance Measurement with a Vertical Undulator Mark Boland Australian Synchrotron University of Melbourne On behalf of Kent Wootton University of Melbourne Oxford, 10 July 2013 Low Emittance Ring Workshop
Jan 01, 2016
Vertical Emittance Measurement with a Vertical Undulator
Mark BolandAustralian SynchrotronUniversity of Melbourne
On behalf of
Kent WoottonUniversity of Melbourne
Oxford, 10 July 2013Low Emittance Ring Workshop
LER 2013, Oxford - Mark Boland 2
Abstract• Method developed to measure the vertical emittance in a storage
ring using a vertical undulator. (K. P. Wootton, M. J. Boland, et al. (2012). "Observation of Picometer Vertical Emittance
with a Vertical Undulator." Physical Review Letters 109(19): 194801.)
• Measure the ratio of the odd and even harmonic peaks.• Observed ultra low vertical emittance on SLSA storage ring.• Characterised the undulator radiation and got good agreement
with calculated radiation using measured magnetic field maps.• Improved sensitivity by scanning the e-beam and collect statistics• Planned improvements by measuring the photon polarisation.
10 July 2013
LER 2013, Oxford - Mark Boland 3
Overview of the Method• APPLE II undulator on the Soft X-ray
beamline at the Australian Synchrotron(B. C. Cowie, A. Tadich, and L. Thomsen, AIP Conf. Proc.
1234, 307 (2010).)
• Phase the magnets to vertical polarisation
10 July 2013
LER 2013, Oxford - Mark Boland 4
Spectral Measurement Results
10 July 2013
LER 2013, Oxford - Mark Boland 5
Cross Check with X-ray Pinhole Camera
10 July 2013
LER 2013, Oxford - Mark Boland 6
Sensitivity to Pinhole Size and Beam Decay
10 July 2013
LER 2013, Oxford - Mark Boland 7
Undulator Characterisation
• Blade scans to observe vertical distribution
• Asymmetry observe between the top and bottom peak
• Comparison with SPECTRA simulations of 2D radiation
• SPECTRA tracks of e-beam through measured magnetic field also produce assymetry
10 July 2013
LER 2013, Oxford - Mark Boland 8
New Approach
10 July 2013
• Time averaging• Normalise to beam current
due to 1 hour lifetime at minimised emittance
• Beam bumps instead of blade scans
• Electron beam Orbit bumps through the undulator
• Parallel position bump and vertical angle bumps
Angle scan of the e-beam through the undulator for three different harmonics (red odd, blue even, black odd)
LER 2013, Oxford - Mark Boland 9
Measurement of Latest Emittance Minimisation
• Not sensitive enough to sub pm emittance
• Need to separate p and s modes in the photon beam
• 2D x-ray pixel detector may also help resolve ultra low emttances
10 July 2013
LER 2013, Oxford - Mark Boland 10
Polarisation Simulations
• Improved sensitivity with selection of only vertical photon polarisation
• Acknowledgement of Spring-8 Takano work
10 July 2013
S. Takano, EMIT’ 97, KEK Proceedings 97-20 (1997)
LER 2013, Oxford - Mark Boland 11
Conclusions/further work
• Not sensitive enough for sub pm emittance• Planning polarisation measurements• Seeking interested collaborators (with 2D x-ray detectors?)
10 July 2013