GENERAL NOTES
NORTH
NOT TO SCALE01 LOCATION MAP
VERANDA CLUBRENOVATION
100% REVIEW SET
CODE REVIEW
ABBREVIATIONS
CL
DRAWING ID
SHEET ID
SHEET ID
DRAWING ID
SHEET ID
DRAWING ID
SHEET ID
DRAWING ID
SHEET ID
DRAWING ID
0
0
0-0
NORTH
456 SF123
NAMEROOM
T/ SLAB+0'-0"
0
0000
0 X0-0
0
0
0
X-0000
X-0000
X-0000
X-0000
SYMBOLS LEGENDWINDOW
TYPE
DOORTYPE
CENTERLINE
COLUMNLINE
ELEVATION /HEIGHT
WALL /PARTITION
AREAIDENTIFICATION
NORTHARROW
REVISIONCLOUD
EXTERIORELEVATION
SECTIONCUT
SECTIONDETAIL
CUT
ENLARGEDDETAIL
INTERIORELEVATION
NOTES
PROJECTLOCATION
Project Address:6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
P 1 32
ARCHITECT
ARCHITECTURAL
OWNER M/E/P/FPELEVEN18 Architecture424 East Central Boulevard, #542Orlando, FL 32801
1. THE ATTACHED DRAWING PACKAGE HAS BEEN TRANSMITTED AS A SINGLE DOCUMENT CONSISTING OF MULTIPLE, INTERRELATED COMPONENTS AND, IN SOME CASE, DISCIPLINES. ANYSEPARATION AND/OR BREAKING APART OF ANY INDIVIDUAL COMPONENTS AND/OR DISCIPLINES OF THIS SINGLE DOCUMENT BY THE OWNER, GENERAL CONTRACTOR, AND/ORSUBCONTRACTOR FOR THE PURPOSES SUCH AS, BUT NOT LIMITED TO BIDDING, ESTIMATING, PERMITTING, ETC. IN NO WAY RELIEVES THE RECIPIENT OF THE ORIGINAL SINGLEDOCUMENT FROM BEING RESPONSIBLE FOR ALL INFORMATION CONTAINED WITHIN THE ORIGINAL SINGLE DOCUMENT IN SUCH ACTIVITIES. RECEIPT OF THESE DOCUMENTSCONSTITUTES ACCEPTANCE OF THESE TERMS AND CONDITION BY THE RECIPIENT.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR ISSUING COMPLETE SETS OF THE CONTRACT DOCUMENTS AND DESCRIPTION OF THE SCOPE OF WORK TO EACH OF THE SUBCONTRACTORS,PERSONS, OR ENTITIES FOR BIDDING, COORDINATION AND EXECUTION OF THEIR WORK.
3. ALL REFERENCES TO THE TERM 'CONTRACTOR' INCLUDE THE GENERAL CONTRACTOR AND SUBCONTRACTORS
4. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES, INSPECTIONS AND APPROVALS BY LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. PROVIDE COPIES OFALL TRANSACTIONS TO OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THIS WORK.
5. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE CONTROL OVER ALL CONSTRUCTION MEANS, TECHNIQUES, PROCEDURES AND COORDINATION OF ALL PORTIONS OF THEWORK REQUIRED BY THE CONTRACT DOCUMENTS.
6. CONTRACTOR SHALL FULLY FAMILIARIZE HIMSELF WITH THE CONDITIONS OF THE CONTRACT, LOCAL CONDITIONS RELATING TO LOCATION, ACCESSIBILITY, AND GENERAL CHARACTEROF THE CONSTRUCTION SITE AND LOCAL LABOR CONDITIONS SO THAT HE/SHE UNDERSTANDS THE NATURE, EXTENT, DIFFICULTIES AND RESTRICTIONS RELATED TO THE EXECUTION OFTHIS WORK.
7. G.C. IS RESPONSIBLE FOR CONNECTING UTILITY LINES TO THE BUILDING (REF. M/E/P/FP DRAWINGS).
8. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ORDERS OF ANYPUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK.
9. NEITHER THE ARCHITECT OR ANY OF THEIR CONSULTANTS HAVE EVALUATED THE SITE FOR EXISTING SOIL CONTAMINATION, HAZARDOUS MATERIAL OR TOXIC WASTE. THEREFORE THEARCHITECT OR THEIR CONSULTANTS SHALL NOT BE HELD RESPONSIBLE FOR EXISTING CONTAMINATED, HAZARDOUS OR TOXIC CONDITIONS DISCOVERED AT THE SITE.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES AND SERVICES, WHETHER SHOWN HEREIN OR NOT AND TO PROTECT THEM FROM DAMAGETHROUGHOUT THE COURSE OF THIS WORK. CONTRACTOR SHALL BEAR ALL EXPENSES OF REPAIR OR REPLACEMENT OF UTILITIES, SERVICES, OR OTHER PROPERTY DAMAGED BYOPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF THIS WORK.
11. THESE DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED TO THE ARCHITECT BY OTHERS. THEREFORE THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FORERRORS, OMISSIONS, CONFLICTS, DEFICIENCIES OR INACCURACIES ARISING FROM DISCOVERY OF CONCEALED, UNKNOWN OR DIFFERING CONDITIONS AS A RESULT OF THISCIRCUMSTANCE. CONTRACTOR SHOULD FULLY ACQUAINT HIMSELF WITH THE SITE AND FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO PERFORMING ANY WORK.
12. CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS HE MAY DISCOVER PRIOR TO PURCHASING, INSTALLATION AND/OR CONSTRUCTION.CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERRORS AT NO ADDITIONAL COST TO THE ARCHITECT OR OWNER ONCE WORK HAS COMMENCED. THE MEANS OFCORRECTING THESE ISSUES SHALL BE APPROVED BY THE OWNER.
13. EXISTING CONDITIONS NOT A PART OF THIS PERMIT ARE INDICATED IN THE DRAWINGS AS A SCREENED OR HALF-TONED IMAGE.
14. DO NOT SCALE DRAWINGS. IF A DIMENSION IS UNCLEAR OR NOT MARKED ON DRAWINGS, CONTACT THE ARCHITECT.
15. ALL DIMENSIONS FOR THE CONSTRUCTION INDICATED ARE TO THE CENTERLINE OR THE FACE OF THE STUDS (ROUGH), DEPENDENT ON THE LOCATION OF THE DIMENSION LINE.DIMENSIONS WHICH ARE TO FINISHED SURFACE ARE NOTED AS SUCH, EXCEPT AT EXISTING SURFACES. ALL ANGLES OF PLAN ARE MULTIPLES OF 45° UNLESS NOTED OTHERWISE.
16. G.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING SITE LIGHTING, SIGNAGE LIGHTING, AND EXTERIOR BUILDING LIGHTING. (SEE SITE, CIVIL, AND ELECTRICAL DRAWINGS)
17. IF REQUIRED, CONTRACTOR SHALL CONTRACT WITH A SPECIALTY ENGINEER LICENSED IN THE STATE OF FLORIDA FOR DESIGNING AN AUTOMATIC SPRINKLER SYSTEM COMPLYING WITHALL APPLICABLE CODES. G.C. SHALL SUBMIT SPRINKLER DESIGN AND LAYOUT TO OWNER AND ARCHITECT FOR REVIEW PRIOR TO PURCHASE, INSTALLATION AND/OR CONSTRUCTION.
18. ALL EXTERIOR ELEMENTS, ASSEMBLIES, GLAZING, GLAZING SYSTEMS AND COMPONENTS INCLUDING CLADDING AND CONNECTIONS USED ON THIS WORK, SHALL MEET THE DESIGNWIND PRESSURES SPECIFIED IN COMPLIANCE WITH FBC 1609.1.2. CONTRACTOR SHALL PROVIDE WINDOW AND DOOR MANUFACTURERS TEST REPORTS AND INSTALLATION DETAILS ASPART OF PERMIT SUBMITTAL DOCUMENTATION. SUBMIT SHOP DWGS. OF ALL DOORS AND HARDWARE TO ARCHITECT FOR REVIEW.
19. G.C. SHALL KEEP A COPY OF THE SOILS REPORT ON SITE. ALL CONSTRUCTION WORK SHALL COMPLY WITH ITS RECOMMENDATIONS / REQUIREMENTS.
20. THE LANDLORD WORK LETTERS DATED X-X-X, (INCLUDED HEREIN, REF. SHEETS ______) ARE CONSIDERED PART OF THIS WORK. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TOFAMILIARIZE HIM/HERSELF WITH THE REQUIREMENTS OUTLINED THEREIN. PRIOR TO BEGINNING WORK, NOTIFY ARCHITECT OF ANY CONFLICTS BETWEEN THESE DOCUMENTS.
AFF ABOVE FINISH FLOORACT ACOUSTICAL CEILING TILE
ALUM ALUMINUMAPPRX APPROXIMATEARCH ARCHITECTURALBRG BEARINGB/ BOTTOM OFBLDG BUILDING
CMU CONCRETE MASONRY UNIT(S)
CT CERAMIC TILECO CLEAN-OUT
CL CENTER LINE
COL COLUMNCONC CONCRETE
CJ CONTROL JOINTCONT CONTINUOUS
DIA DIAMETER
DIM DIMENSIONDN DOWNDS DOWNSPOUTDWG DRAWINGDF DRINKING FOUNTAINEA EACHEWC ELECTRICAL WATER COOLER
ELEV ELEVATIONEQ EQUALEQUIP EQUIPMENT
EJ EXPANSION JOINTEXT EXTERIORFIN FINISHFE FIRE EXTINGUISHER
PT PRESSURE TREATEDR RADIUSREINF REINFORCED (REINFORCING)REQ'D REQUIREDRTU ROOF TOP UNIT
TEMP TEMPORARY
T&G TONGUE AND GROOVE
SIM SIMILAR
SQ SQUARESS STAINLESS STEELSTD STANDARD
STL STEELSTRUCT STRUCTURAL
W/ WITHW/O WITHOUT
NIC NOT IN CONTRACT
T/ TOP OF
TYP TYPICALUNO UNLESS NOTED OTHERWISEVERT VERTICALVCT VINYL COMPOSITION TILE
WC WATER CLOSET
WP WATERPROOFWR WATER RESISTANT
WWM WELDED WIRE MESH
TS TUBE STEEL
N/A NOT APPLICABLE
VIF VERIFY IN FIELD
ELEC ELECTRICAL
WH WATER HEATER
WWF WELDED WIRE FABRIC
O-T-O OUTSIDE-TO-OUTSIDE (OUTSIDE DIMENSION)
I-T-I INSIDE-TO-INSIDE (INSIDE DIMENSION)
ETR EXISTING TO REMAIN
ATWA ALL THE WAY AROUNDTWOS THROUGH WALL OVERFLOW SCUPPER
FRT FIRE RETARDANT TREATED
PAF POWER ACTUATED FASTENERCLNG CEILING
RO ROUGH OPENINGCLR CLEAR
GC GENERAL CONTRACTOR
SPEC SPECIFICATION
PROJECT NARRATIVE
THIS WORK IS FOR A RENOVATION OF AN EXISTING RESIDENTIAL SPACE OF APPROXIMATELY 86,155 GSF. THE PROPOSED USE IS ARESIDENTIAL OCCUPANCY, WHICH IS CONSISTENT WITH THE ZONING OF THE PROPERTY. THE SCOPE OF WORK IS FOR THE BUILDINGINTERIOR AND SHELL WORK.
THE PROPOSED SCOPE OF WORK INCLUDES, BUT IS NOT LIMITED TO, CONCRETE SLAB-ON-GRADE, INTERIOR METAL FRAMED NON-BEARINGPARTITIONS, NEW RESTROOMS, NEW FINISHES INCLUDING LAY-IN ACOUSTIC CEILINGS AND MILLWORK, NEW KITCHEN EQUIPMENT, NEWELECTRICAL FIXTURES AND DISTRIBUTION FROM THE EXISTING ELECTRICAL PANEL, AND NEW AND/OR MODIFIED MECHANICAL ANDPLUMBING SYSTEMS ASSOCIATED WITH THE RECONFIGURED LAYOUT.
REFERENCED CODES
FLORIDA BUILDING CODE (FBC) - 6th EDITION (2017) FLORIDA ENERGY CONSERVATION CODE - 6th EDITION (2017)FLORIDA PLUMBING CODE - 6th EDITION (2017) FLORIDA FIRE PREVENTION CODE - 6th EDITION (2017)FLORIDA FUEL GAS CODE - 6th EDITION (2017) NATIONAL FIRE PROTECTION ASSOCIATION - NFPA 1 FIRE CODE - 2015FLORIDA MECHANICAL CODE - 6th EDITION (2017) NATIONAL FIRE PROTECTION ASSOCIATION - NFPA 101 LIFE SAFETY CODE - 2015FLORIDA ACCESSIBILITY CODE - 6th EDITION (2017) NATIONAL ELECTRIC CODE - 2014
ALL WALL, FLOOR AND CEILING FINISHES SHALL COMPLY WITH NFPA 101 SECTION 10.2.
REQUIRED FIRE-RESISTANCE FOR BUILDING ELEMENTS (FBC TABLE 601)STRUCTURAL FRAME - 0 HOURS NONBEARING WALLS (INTERIOR) - 0 HOURSBEARING WALLS (INTERIOR) - 0 HOURS NONBEARING WALLS (EXTERIOR) - 0 HOURSBEARING WALLS (EXTERIOR) - 0 HOURS FLOOR CONSTRUCTION - 0 HOURS
ROOF CONSTRUCTION - 0 HOURS
ARCHITECT'S STATEMENT OF FACTBY SIGNING AND SEALING THIS DRAWING, THE ARCHITECT ACKNOWLEDGES THAT TO THE BEST OF HIS/HER KNOWLEDGE, THESE DRAWINGSAND THE PROPOSED WORK COMPLY WITH THE MINIMUM APPLICABLE BUILDING CODES AND FIRE SAFETY REGULATIONS AS DETERMINEDBY THE LOCAL AUTHORITY HAVING JURISDICTION.
COVERA000
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
Electrical Wings Demolition PlansLighting PlansWing A Lighting PlansWing D Lighting PlansPower & Systems PlanPanel SchedulesPanel Schedules & Riser Diagram
A206 Pool Plan
Enlarged D Floor Plan & RCPA512
Millwork DetailsA602A603 Millwork Details
A002a Phasing Plan
ARCHITECT'S GENERAL CONDITIONS
I GENERAL CONDITIONS
1. THESE INSTRUCTIONS ARE TO BE FOLLOWED BY ALL CONTRACTORS AND SUBCONTRACTORS WHENPERFORMING THIS WORK. FAILURE TO DO SO MAY RESULT IN THE SUSPENSION OF ALL ACTIVITIESUNTIL DISPUTES ARE RESOLVED. ANY EXPENSES AND/OR DAMAGES INCURRED AS A RESULT OFDELAYS IN THE COMPLETION OF THE WORK DUE TO CONTRACTORS DISREGARD OF THESEINSTRUCTIONS SHALL BE BORNE BY THE CONTRACTOR.
2. CONTRACTOR SHALL PROVIDE AND MAINTAIN FULL INSURANCE AS REQUIRED BY THE GENERALCONDITIONS OF THE OWNER. INSURANCE (EXCEPT WORKERS COMPENSATION) SHALL INCLUDEARCHITECT AS ADDITIONAL INSURED. EVIDENCE OF INSURANCE SHALL BE PROVIDED TO THE OWNERAND ARCHITECT PRIOR TO COMMENCING WORK.
3. ARCHITECT IS NOT RESPONSIBLE FOR ERRORS, OMISSIONS OR DELAYS BY THE CONTRACTOR.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR, PROVIDE, AND PAY FOR ALL MATERIALS, LABOR,EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT, WAREHOUSING, TRANSPORTATION ANDDELIVERY COSTS, HOISTING, REMOVAL AND DISPOSAL OF TRASH AND DEBRIS, AND OTHER FACILITIESAND SERVICES NECESSARY FOR THE EXECUTION AND COMPLETION OF THIS WORK AND THAT OFHIS/HER SUBCONTRACTORS.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR ACTS AND OMISSIONS OF THE CONTRACTORSEMPLOYEES, SUBCONTRACTORS AND THEIR AGENTS AND EMPLOYEES, AND ANY OTHER PERSONSPERFORMING ANY OF THE WORK UNDER A CONTRACT WITH THE CONTRACTOR.
6. OWNER MAY PERFORM ADDITIONAL WORK IN THIS AREA THAT MAY OR MAY NOT BE A PART OF THISCONTRACT WITH HIS OWN FORCES, UNDER SEPARATE CONTRACTS AND/OR WITH OTHERCONTRACTORS WHICH MAY BE WORKING ON THE PREMISES SIMULTANEOUS WITH THE DURATIONOF THIS WORK. NO ACTION SHALL BE TAKEN ON THE PART OF THIS CONTRACTOR OR ANYSUBCONTRACTOR TO IMPEDE THE ACCESS OR OPERATION OF ANY OTHER CONTRACTOR ON THEPREMISES, REGARDLESS OF CONTRACTING PARTY OR UNION AFFILIATION. ANY CHANGES OR DELAYSARISING FROM CONFLICTS DUE TO THIS CIRCUMSTANCE SHALL BE THE RESPONSIBILITY OF THECONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPATIBILITY, APPROVAL AND APPROPRIATE USEOF ALL ASSEMBLIES AND COMPONENTS REQUIRED THAT ARE NOT SPECIFICALLY IDENTIFIED ORSPECIFIED AS PART OF THIS WORK BUT MAY BE REQUIRED BY JURISDICTIONAL AGENCIES HAVINGAUTHORITY OR THAT MAY BE REQUIRED TO COMPLETE THIS WORK.
8. CONTRACTOR IS RESPONSIBLE FOR WORKSITE SAFETY AND SHALL TAKE NECESSARY PRECAUTIONSTO ENSURE THE SAFETY AND PROTECTION OF THE WORKERS AND BUILDING OCCUPANTS AT ALLTIMES. REQUIREMENTS INCLUDE, BUT SHALL NOT BE LIMITED TO O.S.H.A. PART 1926, LATESTEDITION IN FORCE.
9. THE SPRINKLER SUBCONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND LAYOUT OF THE SYSTEM,AND SUBMISSION OF ANY DRAWINGS, EQUIPMENT INFORMATION AND FLOW CALCULATIONS ORTEST DATA REQUIRED BY GOVERNING AUTHORITIES.
10. CONTRACTOR IS RESPONSIBLE FOR CONTRACTING WITH AN ENGINEER LICENSED IN THE STATEWHERE THE WORK IS BEING PERFORMED TO PROVIDE LIGHT GAUGE STEEL STUD FRAMING DESIGN(SPACINGS, GAUGES, SIZES, CONNECTIONS, ETC.)
11. CONTRACTORS CONTRACT AMOUNT SHALL INCLUDE A CONTINGENCY SUM OF 4% TO BE USED TOCOVER COSTS ARISING FROM CONCEALED CONDITIONS WHICH COULD NOT HAVE BEEN REASONABLYFORESEEN OR ANTICIPATED, AND CHANGES IN SCOPE ARISING FROM ASSUMPTIONS ANDCLARIFICATIONS PROVIDED BY THE CONTRACTOR TO THE OWNER AND ARCHITECT.
12. THE AUTHORITY HAVING JURISDICTION MAY REQUIRE A SURVEY BE PERFORMED AND SUBMITTED TODEMONSTRATE THE STRENGTH OF RADIO SIGNALS FOR EMERGENCY SERVICES PERSONNEL. THIS ISNOT INCLUDED IN THE SCOPE OF WORK. BASED ON THE RESULTS OF THE SURVEY, THE AUTHORITYHAVING JURISDICTION MAY REQUIRE THAT A TWO-WAY RADIO COMMUNICATION ENHANCEMENTSYSTEM BE PROVIDED. THE DESIGN OF THIS SYSTEM IS NOT INCLUDED IN THE SCOPE OF WORK.
II CHANGE ORDERS
1. CONTRACTORS DETERMINATION AND COMPLIANCE WITH GOVERNING REGULATIONS AND ORDERSAS ISSUED BY GOVERNING AUTHORITIES DOES NOT CONSTITUTE SUBSTITUTIONS AND DOES NOTCONSTITUTE A BASIS FOR CHANGE ORDERS.
2. ALL CHANGES, REVISIONS AND MODIFICATIONS TO THE WORK SHALL BE DOCUMENTED AND ISSUEDBY THE ARCHITECT.
3. NO CONTRACTOR OR SUBCONTRACTOR SHALL PERFORM ADDITIONAL WORK UNLESS DIRECTED BYOWNER, OR ARCHITECT. ADDITIONAL CHARGES WILL NOT BE APPROVED FOR WORK WITHOUTPROPER AUTHORIZATION.
4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COSTS INCURRED FOR NONCOMPLIANCE WITHTHESE CONTRACT DOCUMENTS. CONTRACTOR WILL NOT BE ALLOWED CHANGE ORDERS FORPROBLEMS ARISING FROM NEGLECT OF PROVISIONS INCLUDED IN THESE CONDITIONS.
III EXISTING CONDITIONS
1. ANY AREA OUTSIDE THE LIMITS OF CONSTRUCTION DISTURBED BY OPERATIONS OF THECONTRACTOR SHALL BE RESTORED AT THE CONTRACTORS EXPENSE.
2. CONTRACTOR SHALL ACCEPT PREMISES AS FOUND. OWNER AND ARCHITECT ACCEPTS NORESPONSIBILITY FOR THE CONDITION OF THE EXISTING SITE OR STRUCTURES AT THE TIME OFBIDDING OR THEREAFTER.
3. CONTRACTOR SHALL TAKE EXCEPTIONAL CARE TO PROTECT AND MAINTAIN EXISTING BUILDING ANDPROPERTY AND SHALL CLEAN OR REPAIR ANY DAMAGE TO SAME CAUSED BY HIS/HERSUBCONTRACTORS, SUPPLIERS AND CRAFTSMAN AT NO COST TO THE OWNER.
4. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO PURCHASINGMATERIALS, INSTALLATON OR PERFORMING ANY WORK. INCLUDE COST FOR ALL WORK DESCRIBEDIN CONTRACT DOCUMENTS AND REQUIRED OR IMPLIED BY EXISTING CONDITIONS. BIDDERS SHALLBE RESPONSIBLE FOR LACK OF VERIFICATION. NOTIFY ARCHITECT OF ANY CONFLICTS BETWEEN THEDRAWINGS AND EXISTING CONDITIONS RELATED TO THE EXECUTION OF THIS WORK.
5. ALL DEMOLITION ACTIVITIES SHALL COMPLY WITH NFPA CODE 241 'BUILDING CONSTRUCTION',ANSI-A10 SERIES STANDARD FOR 'SAFETY REQUIREMENTS' FOR CONSTRUCTION AND DEMOLITION',NECA ELECTRICAL DESIGN LIBRARY 'TEMPORARY ELECTRICAL FACILITIES', AND 'MANUAL OFACCIDENT PREVENTION IN CONSTRUCTION' OF THE ASSOCIATED GENERAL CONTRACTORS OFAMERICA.
6. CONTRACTOR SHALL VERIFY THE INTEGRITY OF ALL EXISTING FIRE RATED OPENINGS WITHIN THESCOPE OF THIS WORK AND SHALL BE RESPONSIBLE FOR THE FIRE-SAFING AS REQUIRED BYJURISDICTIONAL AUTHORITIES TO PROVIDE A POSITIVE SMOKE-TIGHT SEAL TO MAINTAIN INTEGRITYOF WALL CONSTRUCTION AND RATING.
7. CONTRACTOR SHALL TAKE NECESSARY MEASURES TO ENSURE THAT NEIGHBORING TENANTS ANDRESIDENTS ARE NOT DISTURBED IN ANY WAY DURING THE CONSTRUCTION PROCESS. ANY WORKCREATING LOUD NOISES, HAZARDOUS FUMES OR NOXIOUS OR OFFENSIVE ODORS MUST BECOORDINATED WITH OWNER IN ADVANCE SO ACCOMODATIONS CAN BE MADE.
8. ANY CONTACT WITH TENANTS OF SURROUNDING PROPERTIES SHALL BE CONDUCTED IN THE MOSTCOURTEOUS MANNER POSSIBLE.
9. IF CONSTRUCTION IS TAKING PLACE WITHIN AN OCCUPIED SPACE OR STRUCTURE, CONTRACTORSHALL TAKE MEASURES TO ENSURE THAT DAY-TO-DAY OPERATIONS ARE NOT DISRUPTED ORAFFECTED IN ANY WAY.
10. PATCH WALLS, FLOORS AND CEILINGS AS REQUIRED ACCOMMODATING NEW CONSTRUCTION ANDFINISHES.
11. CONTRACTOR SHALL COORDINATE W/OWNER REGARDING THE REMOVAL, DISPOSAL OR SALVAGE OFEXISTING FIXTURES, EQUIPMENT & FURNISHINGS EFFECTED BY THIS WORK.
12. ANY PORTION OF THIS WORK SHALL NOT OBSTRUCT OR CAUSE TO BE INOPERATIVE THE FIREPROTECTION SYSTEMS OF EXISTING SITE AND/OR ADJACENT PROPERTIES. COORDINATE ALL WORKINVOLVING EXISTING FIRE ALARM/VOICE EVACUATION SYSTEM(S) WITH OWNER.
IV CONTRACT DOCUMENTS
1. BUILDING DEPARTMENT APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USEDBY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THECONTRACTOR SHALL ALSO MAINTAIN, IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALLREVISIONS, ADDENDUM'S AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES. THESE ARE TO BEKEPT UNDER THE CARE OF THE SUPERINTENDENT.
2. ALL CONSTRUCTION ITEMS NOT SPECIFIED OR INDICATED ON DRAWINGS SHALL BE COORDINATED W/ARCHITECT AND/OR ADDRESSED BY THE OWNER, THE CONTRACTOR OR HIS SUBCONTRACTORS.
3. CONTRACTOR SHALL BRING ANY CONFLICTS OR DISCREPANCIES FOUND IN THE DRAWINGS TO THEATTENTION OF THE ARCHITECT AND OWNER PRIOR TO PURCHASING, INSTALLATION AND/ORCONSTRUCTION.
4. MATERIALS, PRODUCTS AND ASSEMBLIES SPECIFIED IN THIS WORK BY THE ARCHITECT, ARE BASEDUPON LITERATURE, DRAWINGS OR OTHER DESCRIPTIVE MATERIALS SUPPLIED BY THEMANUFACTURER. IF ANY PRODUCT, MATERIAL OR ASSEMBLY FAILS TO MEET THE CLAIMS OF THEMANUFACTURER WHEN INSTALLED AND USED IN ACCORDANCE WITH THE MANUFACTURERSRECOMMENDATIONS, THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR LESS THANSATISFACTORY RESULTS.
5. CONTRACTOR SHALL BE RESPONSIBLE TO REPORT TO AND DISCUSS WITH THE ARCHITECT PRIOR TOPURCHASING ANY MATERIALS OR INSTALLATIONS SPECIFIED OR INDICATED ON THE DRAWINGSWHICH THE CONTRACTOR BELIEVES WILL NOT PROVIDE SATISFACTORY RESULTS. CONTRACTOR WILLPROVIDE A WORKABLE SOLUTION TO THE ARCHITECT FOR REVIEW PRIOR TO INSTALLING. IFCONTRACTOR FAILS TO NOTIFY THE ARCHITECT OR IF RECOMMENDATIONS ARE ACCEPTED,CONTRACTOR WILL BE RESPONSIBLE FOR INSTALLATION AND SATISFACTORY RESULTS.
6. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS. DO NOT SCALE DRAWINGS TO DETERMINELOCATIONS. LARGE SCALE DRAWINGS GOVERN OVER SMALLER SCALE DRAWINGS. ARCHITECT SHALLBE NOTIFIED OF ANY DISCREPANCY WHICH OCCURS PRIOR TO CONTINUING WITH THE WORK.
V SHOP DRAWINGS, SUBMITTALS & SUBSTITUTIONS
1. CONTRACTOR SHALL PROCURE MATERIALS SO AS NOT TO DELAY SUBSTANTIAL COMPLETION.NOTIFY OWNER WHEN SUBMITTING FINAL BID OF ANY MATERIAL DELIVERY WHICH COULD DELAYCOMPLETION OF CONTRACT BEYOND THE CONTRACT DATE.
2. G.C. SHALL SUBMIT SHOP DRAWINGS AND PRODUCT INFORMATION PRIOR TO PURCHASING,INSTALLATION AND/OR CONSTRUCTION.
3. ALL SUBMITTALS TO THE ARCHITECT SHALL BE SUBMITTED 16 DAYS PRIOR TO DATE REQUIRED.
4. CONTRACTORS SHALL REVIEW ALL SUBMITTALS PRIOR TO SUBMITTING TO ARCHITECT FORARCHITECTS REVIEW. SUBMITTALS SHALL BEAR THE STAMP OF THE CONTRACTOR INDICATINGHIS/HER REVIEW. NO SUBMITTAL SHALL BE PROCESSED BY ARCHITECT WITHOUT THIS STAMP.
5. MANUFACTURER'S OF SPECIFIED ITEMS ARE NOTED FOR QUALITY AND DESIGN. SUBSTITUTEPRODUCTS ARE SUBJECT TO APPROVAL BY ARCHITECT AND OWNER. WHERE SUBSTITUTIONS OFEQUIVALENT PRODUCTS OR ASSEMBLIES ARE PERMITTED, CONTRACTOR IS ENCOURAGED TO SUBMITALTERNATE PRODUCTS FOR CONSIDERATION IN AN EFFORT TO REDUCE THE CONSTRUCTION COSTOR TIME. REASONABLE REQUESTS WILL BE REVIEWED FOR COMPLIANCE WITH THE INTENT OF THECONSTRUCTION DOCUMENTS. IF DOCUMENTS STATE THAT SUBSTITUTIONS ARE NOT PERMITTED,CONTRACTOR SHALL PROVIDE MANUFACTURER/PRODUCT SPECIFIED.
VI FIRE-RESISTANCE-RATED CONSTRUCTION
1. REFERENCE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR DETAILS OF UTILITY WALLPENETRATIONS. ALL FIRE-RATED WALLS MUST BE CLEARLY AND PERMANENTLY LABELED ABOVEFINISH CEILING LEVEL AS REQUIRED BY CODE.
2. ALL FIRE-RATED MATERIALS, ASSEMBLIES AND PENETRATIONS MUST COMPLY WITH REQUIREMENTSOF THEIR ASSOCIATED U.L. (OR OTHER APPROVED TESTING AGENCY) DESIGN.
3. CONTRACTOR SHALL ATTACH AND STAGGER WALLBOARD ON ALL FIRE-RATED WALLS AS REQUIREDBY U.L. DESIGN DESCRIPTION.
VII EXECUTION
1. CONSTRUCTION BARRICADES ARE TO BE INSTALLED TO PREVENT ACCESS BY UNAUTHORIZEDPERSONAL TO CONSTRUCTION AREA. BARRICADES SHALL BE CONSTRUCTED IN A MANNER TOPREVENT DEMOLITION DEBRIS AND DUST FROM CONTAMINATING ADJACENT AREAS.
2. CONTRACTOR SHALL EXAMINE ALL SURFACES TO DETERMINE THAT THEY ARE SOUND, DRY, CLEANAND READY TO RECEIVE FINISHES PRIOR TO INSTALLATION. START OF INSTALLATION SHALL IMPLYACCEPTANCE OF SUBSTRATE AND SHALL NOT BE GROUNDS FOR CLAIMS AGAINST IMPROPERPERFORMANCE OF INSTALLED MATERIALS.
3. PERFORM ALL WORK IN STRICT ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS ANDINSTRUCTIONS AND IN A MANNER CONSISTENT WITH THE HIGHEST STANDARD OF WORKMANSHIP.
4. ALL FURNISHINGS AND EQUIPMENT SHALL BE PROVIDED AND INSTALLED BY THE OWNER UNLESSNOTED OTHERWISE. CONTRACTOR SHALL COORDINATE WITH OWNER'S CONSULTANTS ANDREPRESENTATIVES TO PROVIDE ACCESS SO WORK CAN BE ACCOMPLISHED IN A TIMELY MANNER.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE WORK IS INPROGRESS, AND UNTIL THE JOB IS COMPLETE AND HAS BEEN ACCEPTED BY THE OWNER.
6. POSSESSION, USE OR BEING UNDER THE INFLUENCE OF ALCOHOL, NARCOTICS OR ILLEGALSUBSTANCES OF ANY TYPE ON THE PREMISES IS STRICTLY PROHIBITED.
7. CONTRACTOR SHALL INSTALL AND MAINTAIN ALL NECESSARY COVERINGS, PROTECTIVE ENCLOSURESAND DUST BARRIERS TO PROTECT ALL WORK AND FINISHES. REPAIR AND REPLACE ANY DAMAGESCAUSED BY IMPROPER PROTECTIONS AT NO ADDITIONAL COST TO THE OWNER.
8. PROVIDE TEMPORARY WATERTIGHT WEATHERPROOF CLOSURES AT ALL ROOF OPENINGS UNTILAFTER INSTALLATION OF ROOFTOP MOUNTED MECHANICAL UNITS, DRAINS, VENTS, ETC. ROOF ISTHEN TO BE SEALED IN ACCORDANCE WITH ROOF WARRANTY.
9. PROVIDE CONTROL JOINTS TO PREVENT CRACKING IN ALL MATERIALS AND ASSEMBLIES. SUBMITCONTROL JOINT LAYOUTS TO OWNER AND ARCHITECT FOR REVIEW PRIOR TO PURCHASE,INSTALLATION AND / OR CONSTRUCTION.
10. ALL LOAD BEARING WALLS AND NON LOAD BEARING CMU WALLS ARE TO BE CAULKED ATINTERSECTIONS. TYPICAL.
11. WHERE DISSIMILAR METALS CONTACT, PAINT FACE OF ONE WITH TWO COATS OF BITUMINOUS PAINTAT THE AREA OF CONTACT.
12. ALL ATTACHMENT HARDWARE SHALL BE APPROPRIATELY CAMOUFLAGED AND CONCEALED. FINISHCOLOR OF ALL ATTACHMENT HARDWARE SHALL MATCH ADJACENT SURFACES U.N.O.
13. PROVIDE PRESSURE TREATED WOOD FOR ALL FRAMING, BLOCKING, FURRING, NAILING STRIPS, BUILTINTO EXTERIOR MASONRY WALLS, WOOD IN CONTACT WITH CONCRETE AND IN CONJUNCTION WITHROOFING AND MOISTURE-PERMEABLE FLOORS. PROVIDE FIRE-RETARDANT TREATED WOOD FORCONCEALED BLOCKING AND FOR EXPOSED LUMBER AND PLYWOOD IN HABITABLE SPACE.NON-STRUCTURAL WOOD ON EXTERIOR WALLS TO BE MOISTURE-RESISTANT.
14. ALL WOOD, LUMBER AND PLYWOOD MATERIALS SHALL BE FIRE-RESISTANT AND/OR FIRE-RATED ASREQUIRED BY CODE.
15. COMBUSTIBLE MATERIALS SHALL NOT BE PERMITTED IN THE RETURN AIR PLENUM. ALL INSULATIONEXPOSED TO CEILING PLENUM SHALL BE FIRE AND DUST PROOF.
16. CONTRACTOR SHALL PROVIDE SOLID 2" WOOD BACKING WITHIN WALLS FOR ANCHORAGE OF ALLWALL MOUNTED SHELVES, RAILS, TOILET ACCESSORIES, WOODWORK, ETC. AND AT ALL LOCATIONSDIRECTED BY OWNER. 2x6 CONT. WOOD BLOCK'G SHALL BE PROVIDED AT TOP AND BOTTOM OF ALLMILLWORK. COORDINATE LOCATION OF ALL BLOCKING / BACKING W ID DWGS. ALL WOOD BACKINGSHALL MEET THE REQUIREMENTS OF FBC 603 FOR COMBUSTIBLE MATERIAL.
17. CONTRACTOR SHALL PROVIDE, FRAME AND FINISH ALL OPENINGS AS REQUIRED FOR ELECTRICALAND MECHANICAL PENETRATIONS. ELECTRICAL PANELS, JUNCTION BOXES, RECESSED CABINETS,ETC. OCCURRING IN FIRE-RATED WALLS SHALL BE CONSTRUCTED IN ACCORDANCE WITH U.L. DESIGNREQUIREMENTS.
18. COORDINATE WITH ELECTRICAL CONTRACTOR REGARDING THE MOUNTING HEIGHT OF ALL SWITCHESAND OUTLETS AT MILLWORK, COUNTERS, SHELVING, SINKS ETC. COMPLY WITH APPLICABLEACCESSIBILITY REQUIREMENTS. REFER QUESTIONABLE MOUNTING HEIGHTS TO ARCHITECT FORREVIEW.
19. ALL PENETRATIONS THROUGH ROOF SHALL BE COORDINATED WITH THE HOLDER OF THE ROOFWARRANTY AND SHALL NOT VOID ANY EXISTING WARRANTIES IN ANY WAY. PROVIDE POSITIVEDRAINAGE AWAY FROM OPENINGS. CONTRACTOR IS SOLELY RESPONSIBLE FOR MAINTAININGINTEGRITY OF ROOFING AND ROOF WARRANTY. COORDINATE WITH OWNER.
20. SMOKING IS PROHIBITED INSIDE THE BUILDING AT ANY TIME.
21. COORDINATE THE STAGING AREA WITH THE OWNER OR OWNERS REPRESENTATIVE PRIOR TOSTARTING WORK. G.C. SHALL MAINTAIN A CLEAN AND WELL DEFINED STAGING AREA. PROVIDEDEMISING WALLS / VISUAL SCREENS WHERE REQUIRED BY OWNER OR AHJ.
22. STORAGE OF MATERIALS: CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER CARE ANDPROTECTION OF ALL HIS/HER MATERIALS, EQUIPMENT, TOOLS, ETC. NO SUBCONTRACTOR SHALLSTORE HIS/HER MATERIALS, EQUIPMENT, TOOLS, ETC., SO THAT THEY IMPEDE THE WORK OF ANYOTHER SUBCONTRACTOR OR THE USE OF THE BUILDING BY THE OWNER.
23. CLEANUP: CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEANUP OF DEBRIS ACCUMULATED BYHIS/HER WORK AND THAT OF HIS/HER SUBCONTRACTORS AND SUPPLIERS. AT THE COMPLETION OFTHE DAYS WORK, CONTRACTOR SHALL REMOVE ALL TOOLS AND DEBRIS AND LEAVE CONSTRUCTIONAREA - INCLUDING OUTDOORS - CLEAN AND FREE OF OBSTRUCTION. OCCUPIED AREAS SHALL BEMAINTAINED IN A CLEAN AND ORDERLY MANNER AT ALL TIMES.
24. TRASH AND RECYCLE DUMPSTERS SHALL BE LOCATED AS APPROVED BY OWNER. USE OF EXISTINGTRASH DUMPSTERS AND COMPACTORS SHALL NOT BE UTILIZED UNDER ANY CIRCUMSTANCES.
25. PARKING: CONTRACTOR SHALL COORDINATE THE PARKING AREA WITH THE OWNER AND OWNER'SREPRESENTATIVE PRIOR TO START OF THE WORK. VEHICLES ARE NOT PERMITTED TO REMAINPARKED IN HANDICAPPED DESIGNATED SPACES. LOADING AREAS ARE FOR LOADING ANDUNLOADING ONLY.
26. G.C. SHALL PROVIDE AND INSTALL PORTABLE FIRE EXTINGUISHERS AS INDICATED ON PLAN AND ASREQUIRED BY AHJ. PROVIDE TYPE AND SIZE REQUIRED AT THE LOCATIONS INDICATED. IF VISIBLE TOTHE PUBLIC, PROVIDE A RECESSED CABINET, COORDINATE AND VERIFY W/ SPECIFICATIONS.MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER SHALL BE 75 FEET.
VIII CLOSE-OUT
1. G.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ADDRESS / UNIT NUMBER SIGNAGE AT FRONTAND REAR ENTRIES OR AS INDICATED ON DRAWINGS. SIGNAGE TO MEET LOCAL CODES.
2. 24 HOURS PRIOR TO PUNCH-LIST OF ANY PHASE, THE CONTRACTOR SHALL THOROUGHLY CLEAN ALLSURFACES OF DUST, DEBRIS, AND LOOSE CONSTRUCTION MATERIAL.
3. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL CLEAN THE WORK AREA TO OWNERSSATISFACTION. FINAL CLEANUP SHALL INCLUDE THE FOLLOWING: VACUUM OR MOP ALL FLOORS.SWEEP, DAMP MOP, AND WAX RESILIENT FLOORING. DUST, DIRT, PAINT DRIPPINGS, OIL, GREASE,MASTIC, ADHESIVES, AND OTHER FOREIGN MATERIALS AND BLEMISHES SHALL BE REMOVED FROMSIGHT-EXPOSED FINISHES, INCLUDING PIPES AND EQUIPMENT. WINDOWS, GLASS UNITS, GLASSDOORS AND MIRRORS SHALL BE WASHED. PAINT OVERRUNS AND PUTTY SMEARS SHALL BEREMOVED AND HARDWARE SHALL BE RUBBED CLEAN WITH FLANNEL CLOTH.
4. WORK DAMAGED DURING CONSTRUCTION OR NOT CONFORMING TO SPECIFIED STANDARDS,TOLERANCES OR MANUFACTURERS INSTRUCTIONS FOR INSTALLATION SHALL BE REPLACED BY THECONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REPLACE OR REMEDY ANY FAULTY,IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP WHICH SHALL APPEAR WITHIN ONE (1)YEAR (OR CONTRACTUALLY AGREED UPON TERM REQUIRED BY OWNER) AFTER THE COMPLETIONAND ACCEPTANCE OF THE WORK UNDER THIS CONTRACT.
6. AN OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM MAY BE REQUIRED. COORDINATEWITH BUILDING OFFICIALS.
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
PHASE 2BUILDING A & SALON ON SECONDFLOOR OF MAIN BUILDING
PHASE 3BUILDING D & REMAINDER OF SECOND FLOOR OFMAIN BUILDING
CORRIDOR TO BE COMPLETEDOVERNIGHT. MUST REMAINOPEN DURING THE DAY.
PHASING LEGEND
02 2ND FLOOR PHASING1/32" = 1'-0"
WH
SALON TO REMAIN OPENDURING CONSTRUCTION
PHASING PLANA002a
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
LIFE SAFETY LEGENDEXIT WIDTH INDICATOR (SHOWING CLEAR WIDTHOF OPENING AND NUMBER OF OCCUPANTS THATCLEAR WIDTH CAN SERVE PER CODE)
TRAVEL DISTANCE INDICATOR (SHOWING EXITACCESS TRAVEL DISTANCE FROM MOST REMOTEPOINTS IN EACH AREA)
FIRE EXTINGUISHER IN RECESSED CABINET. SEEA201 FOR SCHEDULE.
EXIT SIGN; LITHONIA QUANTUM SERIES ORAPPROVED EQUAL (ALSO SEE ELEC DWGS)
REFERENCE MEP DWGS FOR DESCRIPTIONS, MANUFACTURER & SPECS.
LIFE SAFETY PLAN NOTES1. EXISTING CONDITIONS TO REMAIN SHOWN HALF-TONE. NEW CONSTRUCTION WITHIN THE LIMITS OF THIS
PERMIT SHOWN GRAPHICALLY HEAVY.
2. AUTOMATIC FIRE SPRINKLER AND FIRE ALARM SYSTEMS MUST BE REVIEWED AND APPROVED BY THE AHJ.
3. WALL RATINGS INDICATED ON LIFE SAFETY PLANS FOR OCCUPANT LIFE SAFETY.
4. REFERENCE SHEET A-000 FOR RATINGS OF STRUCTURAL ELEMENTS.
5. FIRE EXTINGUISHERS SHALL BE LOCATED IN ACCORDANCE W/ THE REQUIREMENTS OF NFPA 10 & SECTION13-6 OF NFPA 1 OF THE FFPC LOCATED SO THAT ALL AREAS ARE WITHIN 75' OF AN EXTINGUISHER. FORMECHANICAL & ELECTRICAL ROOMS, USE A "2A:10B:C" LOCATED SO THAT ALL AREAS ARE WITHIN 50' OF ANEXTINGUISHER. FOR KITCHENS USE A "K" EXTINGUISHER SO THAT ALL AREAS ARE WITHIN 30' OF ANEXTINGUISHER.
6. ALL GATES TO BE EQUIPPED WITH PANIC HARDWARE.
7. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD POSTED PERFBC 1004.3.
8. UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR OTHERWISE INSTRUCTED BY THE ARCHITECT,ELECTRICAL DEVICES SHALL HAVE THE FOLLOWING MOUNTING HEIGHTS. DIMENSIONS ARE TO CENTER OFBOX UNLESS OTHERWISE NOTED:
A. MANUAL FIRE ALARM PULL STATIONS - 48" A.F.F. MAX. TO TOP OF BOX;
B. FIRE ALARM SPEAKER/HORN - 1'-0" BELOW CEILING, OR IN CEILING AS REQUIRED;
C. FIRE ALARM STROBE - 80" A.F.F. OR 6" BELOW CEILING, WHICHEVER IS LOWER.
9. TACTILE SIGNAGE SHALL BE PROVIDED AT ALL EXIT DOORS TO MEET THE FOLLOWING CRITERIA:
A. TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR REQUIRING AN EXIT SIGN;
B. TACTILE SIGNAGE SHALL READ AS FOLLOWS: “EXIT”;
C. TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1.
LIFE SAFETY SUMMARY CHART PER FBC TABLE 1004.1.1
FBC 2010FUNCTION OF
SPACE
2,505.35
PROPOSEDAREA (SQ. FT.)
SQ. FT. PEROCCUPANT
OCCUPANTLOAD
EGRESSWIDTH
REQUIRED(HORIZONTAL)
EGRESSWIDTH
PROVIDED(HORIZONTAL)
15 NET 167.02 167.02 X 0.2" = 33.4" 256"
1,641.78 200 GROSS 8.2 8.2 X 0.2" = 1.64"
1,968.25 150 GROSS 13.12 213.12 X 0.2" = 2.6" 256"
8,790.50 -- 559.49 111.85" 256"
ASSEMBLY(UNCONCENTRATED)
KITCHEN
BUSINESS
TOTAL
FBC TABLE 1021.2 REQUIRES THAT THE MAXIMUM EXIT ACCESS TRAVEL DISTANCE NOT EXCEED 75' FOR THE FIRST FLOOR OFA MERCHANTILE OCCUPANCY WITH A SINGLE EXIT. NO TRAVEL DISTANCE EXCEEDS THIS DISTANCE.
256"
LOBBY100
LIBRARY102
DISCOVERYROOM
101
OFFICE104
OFFICE106
OFFICE107
OFFICE108
VESIBULE103
OFFICE105OFFICE
110
OFFICE109
OFFICE111
BREAKROOM112
HVAC113
HVAC114
ROTUNDA116
CORRIDOR115
MAILCORRIDOR
117
ELECTRICAL120
DINING ROOM121
MEN'S RESTROOM118
HVAC &ELECTRICAL
122
WOMEN'SRESTROOM
119
64"256
216.8 300 GROSS 0.72 0.72 X 0.2" = 0.144" 256"STORAGE
TOP OF FIRE EXT SHALL BEINSTALLED SUCH THAT THE TOP IS
NOT MORE THAN 5'-0" AFF
BOT OF FIRE EXT SHALL BEINSTALLED SUCH THAT THE BOT IS
NOT LESS THAN 4" AFF
INSTALLATION OF FIRE EXTINGUISHERS SHALL COMPLY WITH FLORIDA FIREPREVENTION CODE 1 SECTION 13.6.1.1PROVIDE WALL MOUNTED, PORTABLE FIRE EXTINGUISHERS AS INDICATEDON THE PLAN.PROVIDE TYPE 2-A:10-B:C CLASS A LIGHT HAZARD.
3'-6
"
FINISHED FLOOR
FIRE EXTINGUISHER DETAIL02 1/2" = 1'-0"
INDICATES NEW FIRE EXTINGUISHERFE
FIRST FLOOR LIFESAFETY PLAN
A003
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
LIFE SAFETY PLAN NOTES1. EXISTING CONDITIONS TO REMAIN SHOWN HALF-TONE. NEW CONSTRUCTION WITHIN THE LIMITS OF THIS
PERMIT SHOWN GRAPHICALLY HEAVY.
2. AUTOMATIC FIRE SPRINKLER AND FIRE ALARM SYSTEMS MUST BE REVIEWED AND APPROVED BY THE AHJ.
3. WALL RATINGS INDICATED ON LIFE SAFETY PLANS FOR OCCUPANT LIFE SAFETY.
4. REFERENCE SHEET A-000 FOR RATINGS OF STRUCTURAL ELEMENTS.
5. FIRE EXTINGUISHERS SHALL BE LOCATED IN ACCORDANCE W/ THE REQUIREMENTS OF NFPA 10 & SECTION13-6 OF NFPA 1 OF THE FFPC LOCATED SO THAT ALL AREAS ARE WITHIN 75' OF AN EXTINGUISHER. FORMECHANICAL & ELECTRICAL ROOMS, USE A "2A:10B:C" LOCATED SO THAT ALL AREAS ARE WITHIN 50' OF ANEXTINGUISHER. FOR KITCHENS USE A "K" EXTINGUISHER SO THAT ALL AREAS ARE WITHIN 30' OF ANEXTINGUISHER.
6. ALL GATES TO BE EQUIPPED WITH PANIC HARDWARE.
7. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD POSTED PERFBC 1004.3.
8. UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR OTHERWISE INSTRUCTED BY THE ARCHITECT,ELECTRICAL DEVICES SHALL HAVE THE FOLLOWING MOUNTING HEIGHTS. DIMENSIONS ARE TO CENTER OFBOX UNLESS OTHERWISE NOTED:
A. MANUAL FIRE ALARM PULL STATIONS - 48" A.F.F. MAX. TO TOP OF BOX;
B. FIRE ALARM SPEAKER/HORN - 1'-0" BELOW CEILING, OR IN CEILING AS REQUIRED;
C. FIRE ALARM STROBE - 80" A.F.F. OR 6" BELOW CEILING, WHICHEVER IS LOWER.
9. TACTILE SIGNAGE SHALL BE PROVIDED AT ALL EXIT DOORS TO MEET THE FOLLOWING CRITERIA:
A. TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR REQUIRING AN EXIT SIGN;
B. TACTILE SIGNAGE SHALL READ AS FOLLOWS: “EXIT”;
C. TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1.
LIFE SAFETY LEGENDEXIT WIDTH INDICATOR (SHOWING CLEAR WIDTHOF OPENING AND NUMBER OF OCCUPANTS THATCLEAR WIDTH CAN SERVE PER CODE)
TRAVEL DISTANCE INDICATOR (SHOWING EXITACCESS TRAVEL DISTANCE FROM MOST REMOTEPOINTS IN EACH AREA)
FIRE EXTINGUISHER IN RECESSED CABINET. SEEA201 FOR SCHEDULE.
EXIT SIGN; LITHONIA QUANTUM SERIES ORAPPROVED EQUAL (ALSO SEE ELEC DWGS)
REFERENCE MEP DWGS FOR DESCRIPTIONS, MANUFACTURER & SPECS.
LIFE SAFETY SUMMARY CHART PER FBC TABLE 1004.1.1
FBC 2010FUNCTION OF
SPACE
2,258.35
PROPOSEDAREA (SQ. FT.)
SQ. FT. PEROCCUPANT
OCCUPANTLOAD
EGRESSWIDTH
REQUIRED(HORIZONTAL)
EGRESSWIDTH
PROVIDED(HORIZONTAL)
15 NET 150.56 150.56 X 0.2" =30.11" 256"
249.56 200 GROSS 1.25 1.25 X 0.2" = 0.25"
253.83 150 GROSS 1.69 1.69 X 0.2" = 0.338" 256"
8,790.50 -- 856.22 171.24" 256"
ASSEMBLY(UNCONCENTRATED)
KITCHEN
BUSINESS
TOTAL
FBC TABLE 1021.2 REQUIRES THAT THE MAXIMUM EXIT ACCESS TRAVEL DISTANCE NOT EXCEED 75' FOR THE FIRST FLOOR OFA MERCHANTILE OCCUPANCY WITH A SINGLE EXIT. NO TRAVEL DISTANCE EXCEEDS THIS DISTANCE.
256"
528.18 300 GROSS 1.76 1.76 X 0.2" = 0.352" 256"STORAGE
ASSEMBLY OCCUPANCY (UNCONCENTRATED)
KITCHEN OCCUPANCY
STORAGE OCCUPANCY
BUSINESS OCCUPANCY
ASSEMBLY OCCUPANCY (CONCENTRATED)
EXERCISE ROOM OCCUPANCY
4,810.06 7 NET 687.15 687.15 X 0.2" =137.43" 256"
ASSEMBLY(CONCENTRATED)
690.52 50 GROSS 13.81 7.57 X 0.2" = 2.76" 256"EXERCISE
FE
SECOND FLOOR LIFESAFETY PLAN
A004
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
LIFE SAFETY PLAN NOTES1. EXISTING CONDITIONS TO REMAIN SHOWN HALF-TONE. NEW CONSTRUCTION WITHIN THE LIMITS OF THIS
PERMIT SHOWN GRAPHICALLY HEAVY.
2. AUTOMATIC FIRE SPRINKLER AND FIRE ALARM SYSTEMS MUST BE REVIEWED AND APPROVED BY THE AHJ.
3. WALL RATINGS INDICATED ON LIFE SAFETY PLANS FOR OCCUPANT LIFE SAFETY.
4. REFERENCE SHEET A-000 FOR RATINGS OF STRUCTURAL ELEMENTS.
5. FIRE EXTINGUISHERS SHALL BE LOCATED IN ACCORDANCE W/ THE REQUIREMENTS OF NFPA 10 & SECTION13-6 OF NFPA 1 OF THE FFPC LOCATED SO THAT ALL AREAS ARE WITHIN 75' OF AN EXTINGUISHER. FORMECHANICAL & ELECTRICAL ROOMS, USE A "2A:10B:C" LOCATED SO THAT ALL AREAS ARE WITHIN 50' OF ANEXTINGUISHER. FOR KITCHENS USE A "K" EXTINGUISHER SO THAT ALL AREAS ARE WITHIN 30' OF ANEXTINGUISHER.
6. ALL GATES TO BE EQUIPPED WITH PANIC HARDWARE.
7. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD POSTED PERFBC 1004.3.
8. UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR OTHERWISE INSTRUCTED BY THE ARCHITECT,ELECTRICAL DEVICES SHALL HAVE THE FOLLOWING MOUNTING HEIGHTS. DIMENSIONS ARE TO CENTER OFBOX UNLESS OTHERWISE NOTED:
A. MANUAL FIRE ALARM PULL STATIONS - 48" A.F.F. MAX. TO TOP OF BOX;
B. FIRE ALARM SPEAKER/HORN - 1'-0" BELOW CEILING, OR IN CEILING AS REQUIRED;
C. FIRE ALARM STROBE - 80" A.F.F. OR 6" BELOW CEILING, WHICHEVER IS LOWER.
9. TACTILE SIGNAGE SHALL BE PROVIDED AT ALL EXIT DOORS TO MEET THE FOLLOWING CRITERIA:
A. TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR REQUIRING AN EXIT SIGN;
B. TACTILE SIGNAGE SHALL READ AS FOLLOWS: “EXIT”;
C. TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1.
0000"
TRAVELDISTANCE
FE
LIFE SAFETY LEGENDEXIT WIDTH INDICATOR (SHOWING CLEAR WIDTHOF OPENING AND NUMBER OF OCCUPANTS THATCLEAR WIDTH CAN SERVE PER CODE)
TRAVEL DISTANCE INDICATOR (SHOWING EXITACCESS TRAVEL DISTANCE FROM MOST REMOTEPOINTS IN EACH AREA)
FIRE EXTINGUISHER IN RECESSED CABINET. SEEA201 FOR SCHEDULE.
EXIT SIGN; LITHONIA QUANTUM SERIES ORAPPROVED EQUAL (ALSO SEE ELEC DWGS)
REFERENCE MEP DWGS FOR DESCRIPTIONS, MANUFACTURER & SPECS.
LIFE SAFETY SUMMARY CHART PER FBC TABLE 1004.1.1
FBC 2010FUNCTION OF
SPACE
1,436.55
PROPOSEDAREA (SQ. FT.)
SQ. FT. PEROCCUPANT
OCCUPANTLOAD
EGRESSWIDTH
REQUIRED(HORIZONTAL)
EGRESSWIDTH
PROVIDED(HORIZONTAL)
15 NET 95.77 95.77 X 0.2" = 19.15" 256"
337.11 200 GROSS 1.69 1.69 X 0.2" = 0.34"
1,069.64 150 GROSS 7.13 7.13 X 0.2" = 1.43" 256"
8,790.50 -- 310.87 62.17" 256"
ASSEMBLY(UNCONCENTRATED)
KITCHEN
BUSINESS
TOTAL
FBC TABLE 1021.2 REQUIRES THAT THE MAXIMUM EXIT ACCESS TRAVEL DISTANCE NOT EXCEED 75' FOR THE FIRST FLOOR OFA MERCHANTILE OCCUPANCY WITH A SINGLE EXIT. NO TRAVEL DISTANCE EXCEEDS THIS DISTANCE.
256"
321.82 300 GROSS 1.07 1.07 X 0.2" = 0.21" 256"STORAGE
ASSEMBLY OCCUPANCY (UNCONCENTRATED)
KITCHEN OCCUPANCY
STORAGE OCCUPANCY
BUSINESS OCCUPANCY
ASSEMBLY OCCUPANCY (CONCENTRATED)
1,436.48 7 NET 205.21 205.21 X 0.2" =41.04" 256"
ASSEMBLY(CONCENTRATED)
WING A LIFE SAFETYPLAN
A005
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
LIFE SAFETY PLAN NOTES1. EXISTING CONDITIONS TO REMAIN SHOWN HALF-TONE. NEW CONSTRUCTION WITHIN THE LIMITS OF THIS
PERMIT SHOWN GRAPHICALLY HEAVY.
2. AUTOMATIC FIRE SPRINKLER AND FIRE ALARM SYSTEMS MUST BE REVIEWED AND APPROVED BY THE AHJ.
3. WALL RATINGS INDICATED ON LIFE SAFETY PLANS FOR OCCUPANT LIFE SAFETY.
4. REFERENCE SHEET A-000 FOR RATINGS OF STRUCTURAL ELEMENTS.
5. FIRE EXTINGUISHERS SHALL BE LOCATED IN ACCORDANCE W/ THE REQUIREMENTS OF NFPA 10 & SECTION13-6 OF NFPA 1 OF THE FFPC LOCATED SO THAT ALL AREAS ARE WITHIN 75' OF AN EXTINGUISHER. FORMECHANICAL & ELECTRICAL ROOMS, USE A "2A:10B:C" LOCATED SO THAT ALL AREAS ARE WITHIN 50' OF ANEXTINGUISHER. FOR KITCHENS USE A "K" EXTINGUISHER SO THAT ALL AREAS ARE WITHIN 30' OF ANEXTINGUISHER.
6. ALL GATES TO BE EQUIPPED WITH PANIC HARDWARE.
7. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD POSTED PERFBC 1004.3.
8. UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR OTHERWISE INSTRUCTED BY THE ARCHITECT,ELECTRICAL DEVICES SHALL HAVE THE FOLLOWING MOUNTING HEIGHTS. DIMENSIONS ARE TO CENTER OFBOX UNLESS OTHERWISE NOTED:
A. MANUAL FIRE ALARM PULL STATIONS - 48" A.F.F. MAX. TO TOP OF BOX;
B. FIRE ALARM SPEAKER/HORN - 1'-0" BELOW CEILING, OR IN CEILING AS REQUIRED;
C. FIRE ALARM STROBE - 80" A.F.F. OR 6" BELOW CEILING, WHICHEVER IS LOWER.
9. TACTILE SIGNAGE SHALL BE PROVIDED AT ALL EXIT DOORS TO MEET THE FOLLOWING CRITERIA:
A. TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR REQUIRING AN EXIT SIGN;
B. TACTILE SIGNAGE SHALL READ AS FOLLOWS: “EXIT”;
C. TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1.
0000"
TRAVELDISTANCE
FE
LIFE SAFETY LEGENDEXIT WIDTH INDICATOR (SHOWING CLEAR WIDTHOF OPENING AND NUMBER OF OCCUPANTS THATCLEAR WIDTH CAN SERVE PER CODE)
TRAVEL DISTANCE INDICATOR (SHOWING EXITACCESS TRAVEL DISTANCE FROM MOST REMOTEPOINTS IN EACH AREA)
FIRE EXTINGUISHER IN RECESSED CABINET. SEEA201 FOR SCHEDULE.
EXIT SIGN; LITHONIA QUANTUM SERIES ORAPPROVED EQUAL (ALSO SEE ELEC DWGS)
REFERENCE MEP DWGS FOR DESCRIPTIONS, MANUFACTURER & SPECS.
LIFE SAFETY SUMMARY CHART PER FBC TABLE 1004.1.1
FBC 2010FUNCTION OF
SPACE
1,334.11
PROPOSEDAREA (SQ. FT.)
SQ. FT. PEROCCUPANT
OCCUPANTLOAD
EGRESSWIDTH
REQUIRED(HORIZONTAL)
EGRESSWIDTH
PROVIDED(HORIZONTAL)
15 NET 88.94 88.94 X 0.2" =17.79" 256"
231.08 200 GROSS 1.16 1.16 X 0.2" = 0.23"
2,143.1 -- 168.3 33.66" 256"
ASSEMBLY(UNCONCENTRATED)
KITCHEN
TOTAL
FBC TABLE 1021.2 REQUIRES THAT THE MAXIMUM EXIT ACCESS TRAVEL DISTANCE NOT EXCEED 75' FOR THE FIRST FLOOR OFA MERCHANTILE OCCUPANCY WITH A SINGLE EXIT. NO TRAVEL DISTANCE EXCEEDS THIS DISTANCE.
256"
31.19 300 GROSS 0.10 0.10 X 0.2" = 0.02" 256"STORAGE
ASSEMBLY OCCUPANCY (UNCONCENTRATED)
KITCHEN OCCUPANCY
STORAGE OCCUPANCY
ASSEMBLY OCCUPANCY (CONCENTRATED)
546.72 7 NET 78.10 78.10 X 0.2" = 15.62" 256"ASSEMBLY
(CONCENTRATED)
WING D LIFE SAFETYPLAN
A006
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
LIFE SAFETY PLAN NOTES1. EXISTING CONDITIONS TO REMAIN SHOWN HALF-TONE. NEW CONSTRUCTION WITHIN THE LIMITS OF THIS
PERMIT SHOWN GRAPHICALLY HEAVY.
2. AUTOMATIC FIRE SPRINKLER AND FIRE ALARM SYSTEMS MUST BE REVIEWED AND APPROVED BY THE AHJ.
3. WALL RATINGS INDICATED ON LIFE SAFETY PLANS FOR OCCUPANT LIFE SAFETY.
4. REFERENCE SHEET A-000 FOR RATINGS OF STRUCTURAL ELEMENTS.
5. FIRE EXTINGUISHERS SHALL BE LOCATED IN ACCORDANCE W/ THE REQUIREMENTS OF NFPA 10 & SECTION13-6 OF NFPA 1 OF THE FFPC LOCATED SO THAT ALL AREAS ARE WITHIN 75' OF AN EXTINGUISHER. FORMECHANICAL & ELECTRICAL ROOMS, USE A "2A:10B:C" LOCATED SO THAT ALL AREAS ARE WITHIN 50' OF ANEXTINGUISHER. FOR KITCHENS USE A "K" EXTINGUISHER SO THAT ALL AREAS ARE WITHIN 30' OF ANEXTINGUISHER.
6. ALL GATES TO BE EQUIPPED WITH PANIC HARDWARE.
7. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD POSTED PERFBC 1004.3.
8. UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR OTHERWISE INSTRUCTED BY THE ARCHITECT,ELECTRICAL DEVICES SHALL HAVE THE FOLLOWING MOUNTING HEIGHTS. DIMENSIONS ARE TO CENTER OFBOX UNLESS OTHERWISE NOTED:
A. MANUAL FIRE ALARM PULL STATIONS - 48" A.F.F. MAX. TO TOP OF BOX;
B. FIRE ALARM SPEAKER/HORN - 1'-0" BELOW CEILING, OR IN CEILING AS REQUIRED;
C. FIRE ALARM STROBE - 80" A.F.F. OR 6" BELOW CEILING, WHICHEVER IS LOWER.
9. TACTILE SIGNAGE SHALL BE PROVIDED AT ALL EXIT DOORS TO MEET THE FOLLOWING CRITERIA:
A. TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR REQUIRING AN EXIT SIGN;
B. TACTILE SIGNAGE SHALL READ AS FOLLOWS: “EXIT”;
C. TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1.
0000"
TRAVELDISTANCE
FE
LIFE SAFETY LEGENDEXIT WIDTH INDICATOR (SHOWING CLEAR WIDTHOF OPENING AND NUMBER OF OCCUPANTS THATCLEAR WIDTH CAN SERVE PER CODE)
TRAVEL DISTANCE INDICATOR (SHOWING EXITACCESS TRAVEL DISTANCE FROM MOST REMOTEPOINTS IN EACH AREA)
FIRE EXTINGUISHER IN RECESSED CABINET. SEEA201 FOR SCHEDULE.
EXIT SIGN; LITHONIA QUANTUM SERIES ORAPPROVED EQUAL (ALSO SEE ELEC DWGS)
REFERENCE MEP DWGS FOR DESCRIPTIONS, MANUFACTURER & SPECS.
ASSEMBLY OCCUPANCY (UNCONCENTRATED)
LIFE SAFETY SUMMARY CHART PER FBC TABLE 1004.1.1
FBC 2010FUNCTION OF
SPACE
351.56
PROPOSEDAREA (SQ. FT.)
SQ. FT. PEROCCUPANT
OCCUPANTLOAD
EGRESSWIDTH
REQUIRED(HORIZONTAL)
EGRESSWIDTH
PROVIDED(HORIZONTAL)
15 GROSS 23.44 23.44 X 0.2" = 4.7" 256"
351.56 -- 23.44 4.7" 256"
ASSEMBLY(UNCONCENTRATED)
TOTAL
FBC TABLE 1021.2 REQUIRES THAT THE MAXIMUM EXIT ACCESS TRAVEL DISTANCE NOT EXCEED 75' FOR THE FIRST FLOOR OFA MERCHANTILE OCCUPANCY WITH A SINGLE EXIT. NO TRAVEL DISTANCE EXCEEDS THIS DISTANCE.
POOL HOUSE LIFESAFETY PLAN
A007
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
DEMOLITION PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. CONTRACTOR SHALL VERIFY EXTENT OF DEMOLITION WORK PRIOR TO STARTING ANY WORK. COORDINATETHE DEMOLITION WORK WITH THE MECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL, FIRE PROTECTIONAND NEW CONSTRUCTION PLANS.
3. EXISTING UNDERGROUND ELECTRICAL CONDUIT AND SERVICE FEEDERS MAY BE BURIED UNDER THE SLAB.THE CONTRACTOR SHALL LOCATE AND PROTECT ALL ELECTRICAL CONDUITS SERVING AREAS BEYOND THESCOPE OF WORK. PRIOR TO TRENCHING OR CUTTING, CONTRACTOR SHALL PRESENT PROPOSED ROUTE TOOWNERS REPRESENTATIVE, ENGINEER AND ARCHITECT FOR APPROVAL.
4. COORDINATE WITH OWNER AS TO WHAT EQUIPMENT & FINISH ITEMS ARE TO RE-USED SUCH AS RESTROOMFIXTURES AND ACCESSORIES, MOLDINGS, WAINSCOTS, TRIMS, INTERIOR DOORS, INTERIOR GLAZING &ORNAMENTAL ITEMS, CAREFULLY REMOVE & SET-ASIDE FOR RE-USE.
5. WHERE PARTITIONS ARE BEING REMOVED, ALL ELECTRICAL DEVICES SHALL BE DISCONNECTED AND MADESAFE. WHEREVER EXISTING UTILITIES ARE TO BE CAPPED, REROUTED, REMAIN IN PLACE, OR TERMINATED,COORDINATE W/ MEP DWGS.
6. WHERE FLOOR AND WALL FINISHES ARE BEING REMOVED, ALL ADHESIVE RESIDUE, MECHANICALFASTENERS AND MISC. ITEMS SHALL ALSO BE REMOVED. ALL DEPRESSIONS / VOIDS CREATED IN THEEXISTING SLAB DUE TO REMOVAL OF EQUIPMENT SHALL BE FILLED ACCORDINGLY TO BRING THEM UP LEVELAND FINISHED TO MATCH SURROUNDING FINISH SLAB.
RCP DEMOLITION NUMBERED NOTES
REMOVE LIGHT FIXTURE
REMOVE LIGHT FIXTURE TO BE REPLACED WITH LED PER NEW WORK PLANS
REMOVE ACT
REMOVE DECORATIVE WOODWORK
1
2
3
4
1 1
111
1 1 1
1 11
1 1 1
1
2
4
2 2
2
2
2
2
2
2
2
2 2
2
22
2
2
2
2
2
2
2
2
42
4
4 4 4
444
4
4
4
4
4
4
22
2
2 2 2
2
2
2
2
2 2
2 2
2
2
2
2
1
13
13
13
13
13
13
13
13
13 1
3
13
13
13
13
1
NORTH
01 FIRST FLOOR DEMOLITION PLAN1/8" = 1'-0"
0
2'
4'
8'
16'
7. REMOVE ALL ITEMS LOCATED ABOVE CEILING THAT IS NOT A PART OF THE PROPOSED WORK. COORDINATEWITH OWNER AS TO ANY ITEM THAT IS TO BE LEFT UNDISTURBED.
8. WHERE CUTTING OR DEMOLITION OF THE EXISTING BUILDING IS INDICATED OR REQUIRED TOACCOMMODATE NEW CONSTRUCTION, THE STRUCTURAL ENGINEER SHALL BE CONSULTED PRIOR TOBEGINNING OF TASK TO DETERMINE IF THIS WORK WILL IN ANY WAY UNDERMINE THE FOUNDATIONS ORCOMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING, AND TO DETERMINE A COURSE OFCORRECTIVE ACTION FOR RESTORING ANY DAMAGE AND RETURNING THE APPEARANCE TO AN ACCEPTABLELEVEL.
9. WHENEVER POSSIBLE, ALL CUTS IN MASONRY WALLS SHALL OCCUR AT JOINT LINES - COORDINATE WITHNEW CONSTRUCTION.
10. CONTRACTOR SHALL ADEQUATELY BRACE & SUPPORT STRUCTURE AS REQUIRED DURING DEMOLITIONPHASE. USE EXTREME CARE TO NOT DAMAGE SUPPORT BEAMS TO REMAIN.
11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF ALL DEMOLITION MATERIAL INCLUDING ANYEQUIPMENT THAT IS NOT TO BE REUSED.
12. MAINTAIN FIRE EGRESS AT ALL TIMES THROUGHOUT THE COURSE OF THIS WORK.
FLOOR PLAN DEMOLITION NUMBERED NOTES
REMOVE WALL TO DECK
REMOVE DOOR
REMOVE DOOR, RETAIL FOR REINSTALLATION PER NEW WORK PLAN
REMOVE ELECTRICAL PANEL, RETAIN FOR REINSTALLATION PER NEW WORK PLAN
REMOVE MAILBOXES
REMOVE PLUMBING FIXTURE
REMOVE MILLWORK
REMOVE PORTION OF EXTERIOR WALL FOR NEW WINDOW
REMOVE FLOOR AND WALL FINISHES
REMOVE EXISTING ROOM NUMBERS TO BE REPLACED BY VENDOR BY OWNER
REMOVE ELEVATOR CAB FINISHES
1
2
3
4
5
6
7
8
9
2
2
2
2
2
22
2
2
2
22
32
2
22
2
2
1
1
1
1
1
1
1
1
11
1
1
1
7
8
8
13'-2
7 8"4'
-4"
4'-0
"4'
-4"
5
4
4
4
67
9
9
99
9
9
10
10
1010
10
10
10
10
11
119 9
2
FIRST FLOORDEMOLITION
A101
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
DEMOLITION PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. CONTRACTOR SHALL VERIFY EXTENT OF DEMOLITION WORK PRIOR TO STARTING ANY WORK. COORDINATETHE DEMOLITION WORK WITH THE MECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL, FIRE PROTECTIONAND NEW CONSTRUCTION PLANS.
3. EXISTING UNDERGROUND ELECTRICAL CONDUIT AND SERVICE FEEDERS MAY BE BURIED UNDER THE SLAB.THE CONTRACTOR SHALL LOCATE AND PROTECT ALL ELECTRICAL CONDUITS SERVING AREAS BEYOND THESCOPE OF WORK. PRIOR TO TRENCHING OR CUTTING, CONTRACTOR SHALL PRESENT PROPOSED ROUTE TOOWNERS REPRESENTATIVE, ENGINEER AND ARCHITECT FOR APPROVAL.
4. COORDINATE WITH OWNER AS TO WHAT EQUIPMENT & FINISH ITEMS ARE TO RE-USED SUCH AS RESTROOMFIXTURES AND ACCESSORIES, MOLDINGS, WAINSCOTS, TRIMS, INTERIOR DOORS, INTERIOR GLAZING &ORNAMENTAL ITEMS, CAREFULLY REMOVE & SET-ASIDE FOR RE-USE.
5. WHERE PARTITIONS ARE BEING REMOVED, ALL ELECTRICAL DEVICES SHALL BE DISCONNECTED AND MADESAFE. WHEREVER EXISTING UTILITIES ARE TO BE CAPPED, REROUTED, REMAIN IN PLACE, OR TERMINATED,COORDINATE W/ MEP DWGS.
6. WHERE FLOOR AND WALL FINISHES ARE BEING REMOVED, ALL ADHESIVE RESIDUE, MECHANICALFASTENERS AND MISC. ITEMS SHALL ALSO BE REMOVED. ALL DEPRESSIONS / VOIDS CREATED IN THEEXISTING SLAB DUE TO REMOVAL OF EQUIPMENT SHALL BE FILLED ACCORDINGLY TO BRING THEM UP LEVELAND FINISHED TO MATCH SURROUNDING FINISH SLAB.
RCP DEMOLITION NUMBERED NOTES
REMOVE LIGHT FIXTURE
REMOVE LIGHT FIXTURE TO BE REPLACED WITH LED PER NEW WORK PLANS
REMOVE ACT
REMOVE DECORATIVE WOODWORK
1
2
3
4
1
1
1
1
1
2
2
2
2
2
2
2
22
2
2
2
4
1
2
NORTH
01 SECOND FLOOR DEMOLITION PLAN1/8" = 1'-0"
0
2'
4'
8'
16'
WH
7. REMOVE ALL ITEMS LOCATED ABOVE CEILING THAT IS NOT A PART OF THE PROPOSED WORK. COORDINATEWITH OWNER AS TO ANY ITEM THAT IS TO BE LEFT UNDISTURBED.
8. WHERE CUTTING OR DEMOLITION OF THE EXISTING BUILDING IS INDICATED OR REQUIRED TOACCOMMODATE NEW CONSTRUCTION, THE STRUCTURAL ENGINEER SHALL BE CONSULTED PRIOR TOBEGINNING OF TASK TO DETERMINE IF THIS WORK WILL IN ANY WAY UNDERMINE THE FOUNDATIONS ORCOMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING, AND TO DETERMINE A COURSE OFCORRECTIVE ACTION FOR RESTORING ANY DAMAGE AND RETURNING THE APPEARANCE TO AN ACCEPTABLELEVEL.
9. WHENEVER POSSIBLE, ALL CUTS IN MASONRY WALLS SHALL OCCUR AT JOINT LINES - COORDINATE WITHNEW CONSTRUCTION.
10. CONTRACTOR SHALL ADEQUATELY BRACE & SUPPORT STRUCTURE AS REQUIRED DURING DEMOLITIONPHASE. USE EXTREME CARE TO NOT DAMAGE SUPPORT BEAMS TO REMAIN.
11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF ALL DEMOLITION MATERIAL INCLUDING ANYEQUIPMENT THAT IS NOT TO BE REUSED.
12. MAINTAIN FIRE EGRESS AT ALL TIMES THROUGHOUT THE COURSE OF THIS WORK.
FLOOR PLAN DEMOLITION NUMBERED NOTES
REMOVE WALL TO DECK
REMOVE DOOR
REMOVE PORTION OF WALL TO ACCOMMODATE NEW DOOR
REMOVE PLATFORM STAGE
REMOVE FLOOR AND WALL FINISHES
REMOVE EXISTING ROOM NUMBERS TO BE REPLACED BY VENDOR BY OWNER
REMOVE MILLWORK ENTIRELY
REMOVE PLUMBING FIXTURE
REMOVE ELEVATOR CAB FINISHES
1
2
1
1
1
1
2
2
2
2
2
2
2
3
3
4
4
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
7
7
8
7
8
9
9
56
56 5
6
SECOND FLOORDEMOLITION
A102
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
DEMOLITION PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING
THIS WORK.
2. CONTRACTOR SHALL VERIFY EXTENT OF DEMOLITION WORK PRIOR TO STARTING ANY WORK.COORDINATE THE DEMOLITION WORK WITH THE MECHANICAL, ELECTRICAL, PLUMBING,STRUCTURAL, FIRE PROTECTION AND NEW CONSTRUCTION PLANS.
3. EXISTING UNDERGROUND ELECTRICAL CONDUIT AND SERVICE FEEDERS MAY BE BURIED UNDERTHE SLAB. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL ELECTRICAL CONDUITS SERVINGAREAS BEYOND THE SCOPE OF WORK. PRIOR TO TRENCHING OR CUTTING, CONTRACTOR SHALLPRESENT PROPOSED ROUTE TO OWNERS REPRESENTATIVE, ENGINEER AND ARCHITECT FORAPPROVAL.
4. COORDINATE WITH OWNER AS TO WHAT EQUIPMENT & FINISH ITEMS ARE TO RE-USED SUCH ASRESTROOM FIXTURES AND ACCESSORIES, MOLDINGS, WAINSCOTS, TRIMS, INTERIOR DOORS,INTERIOR GLAZING & ORNAMENTAL ITEMS, CAREFULLY REMOVE & SET-ASIDE FOR RE-USE.
5. WHERE PARTITIONS ARE BEING REMOVED, ALL ELECTRICAL DEVICES SHALL BE DISCONNECTED ANDMADE SAFE. WHEREVER EXISTING UTILITIES ARE TO BE CAPPED, REROUTED, REMAIN IN PLACE, ORTERMINATED, COORDINATE W/ MEP DWGS.
6. WHERE FLOOR AND WALL FINISHES ARE BEING REMOVED, ALL ADHESIVE RESIDUE, MECHANICALFASTENERS AND MISC. ITEMS SHALL ALSO BE REMOVED. ALL DEPRESSIONS / VOIDS CREATED INTHE EXISTING SLAB DUE TO REMOVAL OF EQUIPMENT SHALL BE FILLED ACCORDINGLY TO BRINGTHEM UP LEVEL AND FINISHED TO MATCH SURROUNDING FINISH SLAB.
7. REMOVE ALL ITEMS LOCATED ABOVE CEILING THAT IS NOT A PART OF THE PROPOSED WORK.COORDINATE WITH OWNER AS TO ANY ITEM THAT IS TO BE LEFT UNDISTURBED.
8. WHERE CUTTING OR DEMOLITION OF THE EXISTING BUILDING IS INDICATED OR REQUIRED TOACCOMMODATE NEW CONSTRUCTION, THE STRUCTURAL ENGINEER SHALL BE CONSULTED PRIORTO BEGINNING OF TASK TO DETERMINE IF THIS WORK WILL IN ANY WAY UNDERMINE THEFOUNDATIONS OR COMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING, AND TODETERMINE A COURSE OF CORRECTIVE ACTION FOR RESTORING ANY DAMAGE AND RETURNINGTHE APPEARANCE TO AN ACCEPTABLE LEVEL.
9. WHENEVER POSSIBLE, ALL CUTS IN MASONRY WALLS SHALL OCCUR AT JOINT LINES - COORDINATEWITH NEW CONSTRUCTION.
10. CONTRACTOR SHALL ADEQUATELY BRACE & SUPPORT STRUCTURE AS REQUIRED DURINGDEMOLITION PHASE. USE EXTREME CARE TO NOT DAMAGE SUPPORT BEAMS TO REMAIN.
11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF ALL DEMOLITION MATERIAL INCLUDINGANY EQUIPMENT THAT IS NOT TO BE REUSED.
12. MAINTAIN FIRE EGRESS AT ALL TIMES THROUGHOUT THE COURSE OF THIS WORK.
NORTH
02 WING A DEMOLITION RCP3/32" = 1'-0"
0
4'
8'
16'
24'
FLOOR PLAN DEMOLITION NUMBERED NOTES
REMOVE WALL TO DECK
REMOVE DOOR
REMOVE ELECTRICAL PANEL, RETAIN FOR REINSTALLATION PER NEW WORK PLAN
REMOVE MILLWORK
REMOVE EXISTING CARPET AND WALL FINISHES
REMOVE PASS STAINLESS STEEL PASS THROUGH
REMOVE EXISTING ROOM NUMBERS TO BE REPLACED BY VENDOR BY OWNER
1
2
3
4
5
6
RCP DEMOLITION NUMBERED NOTES
REMOVE LIGHT FIXTURE
REMOVE LIGHT FIXTURE TO BE REPLACED WITH LED PER NEW WORK PLANS
REMOVE ACT
REMOVE DECORATIVE WOODWORK
1
2
3
4
22
2
22
2
2
2
2
2
22
2 2
2 2
2
2 2
2
2
2 2 22
2
3
3'-7
1 2"
TO MAIN BUILDING
7
WING A DEMOLTIONA103
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
DEMOLITION PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL
REQUIREMENTS EFFECTING THIS WORK.
2. CONTRACTOR SHALL VERIFY EXTENT OF DEMOLITION WORK PRIOR TOSTARTING ANY WORK. COORDINATE THE DEMOLITION WORK WITH THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL, FIRE PROTECTION ANDNEW CONSTRUCTION PLANS.
3. EXISTING UNDERGROUND ELECTRICAL CONDUIT AND SERVICE FEEDERS MAYBE BURIED UNDER THE SLAB. THE CONTRACTOR SHALL LOCATE AND PROTECTALL ELECTRICAL CONDUITS SERVING AREAS BEYOND THE SCOPE OF WORK.PRIOR TO TRENCHING OR CUTTING, CONTRACTOR SHALL PRESENT PROPOSEDROUTE TO OWNERS REPRESENTATIVE, ENGINEER AND ARCHITECT FORAPPROVAL.
4. COORDINATE WITH OWNER AS TO WHAT EQUIPMENT & FINISH ITEMS ARE TORE-USED SUCH AS RESTROOM FIXTURES AND ACCESSORIES, MOLDINGS,WAINSCOTS, TRIMS, INTERIOR DOORS, INTERIOR GLAZING & ORNAMENTALITEMS, CAREFULLY REMOVE & SET-ASIDE FOR RE-USE.
5. WHERE PARTITIONS ARE BEING REMOVED, ALL ELECTRICAL DEVICES SHALL BEDISCONNECTED AND MADE SAFE. WHEREVER EXISTING UTILITIES ARE TO BECAPPED, REROUTED, REMAIN IN PLACE, OR TERMINATED, COORDINATE W/MEP DWGS.
6. WHERE FLOOR AND WALL FINISHES ARE BEING REMOVED, ALL ADHESIVERESIDUE, MECHANICAL FASTENERS AND MISC. ITEMS SHALL ALSO BEREMOVED. ALL DEPRESSIONS / VOIDS CREATED IN THE EXISTING SLAB DUE TOREMOVAL OF EQUIPMENT SHALL BE FILLED ACCORDINGLY TO BRING THEM UPLEVEL AND FINISHED TO MATCH SURROUNDING FINISH SLAB.
7. REMOVE ALL ITEMS LOCATED ABOVE CEILING THAT IS NOT A PART OF THEPROPOSED WORK. COORDINATE WITH OWNER AS TO ANY ITEM THAT IS TO BELEFT UNDISTURBED.
8. WHERE CUTTING OR DEMOLITION OF THE EXISTING BUILDING IS INDICATED ORREQUIRED TO ACCOMMODATE NEW CONSTRUCTION, THE STRUCTURALENGINEER SHALL BE CONSULTED PRIOR TO BEGINNING OF TASK TODETERMINE IF THIS WORK WILL IN ANY WAY UNDERMINE THE FOUNDATIONSOR COMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING,AND TO DETERMINE A COURSE OF CORRECTIVE ACTION FOR RESTORING ANYDAMAGE AND RETURNING THE APPEARANCE TO AN ACCEPTABLE LEVEL.
9. WHENEVER POSSIBLE, ALL CUTS IN MASONRY WALLS SHALL OCCUR AT JOINTLINES - COORDINATE WITH NEW CONSTRUCTION.
10. CONTRACTOR SHALL ADEQUATELY BRACE & SUPPORT STRUCTURE ASREQUIRED DURING DEMOLITION PHASE. USE EXTREME CARE TO NOT DAMAGESUPPORT BEAMS TO REMAIN.
11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF ALL DEMOLITIONMATERIAL INCLUDING ANY EQUIPMENT THAT IS NOT TO BE REUSED.
12. MAINTAIN FIRE EGRESS AT ALL TIMES THROUGHOUT THE COURSE OF THISWORK.
NORTH
02 WING D DEMOLITION RCP3/32" = 1'-0"
0
4'
8'
16'
24'
AHU
AHU
FLOOR PLAN DEMOLITION NUMBERED NOTES
REMOVE WALL TO DECK
REMOVE DOOR
REMOVE ELECTRICAL PANEL, RETAIN FOR REINSTALLATION PER NEW WORK PLAN
REMOVE EXISTING CARPET AND WALL FINISHES
REMOVE PASS STAINLESS STEEL PASS THROUGH
REMOVE ELECTRICAL PANEL TO BE REINSTALLED PER NEW WORK PLAN
REMOVE EXISTING ROOM NUMBERS TO BE REPLACED BY VENDOR BY OWNER
1
2
3
4
5
6
RCP DEMOLITION NUMBERED NOTES
REMOVE LIGHT FIXTURE
REMOVE LIGHT FIXTURE TO BE REPLACED WITH LED PER NEW WORK PLANS
1
2
2
22222
2
2
222 2
2
2
2
2
2
2
2
2
2
TO MAIN BUILDING
7
2
2
WING D DEMOLITIONPLAN
A104
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
DEMOLITION PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. CONTRACTOR SHALL VERIFY EXTENT OF DEMOLITION WORK PRIOR TO STARTING ANY WORK.COORDINATE THE DEMOLITION WORK WITH THE MECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL,FIRE PROTECTION AND NEW CONSTRUCTION PLANS.
3. EXISTING UNDERGROUND ELECTRICAL CONDUIT AND SERVICE FEEDERS MAY BE BURIED UNDER THE SLAB.THE CONTRACTOR SHALL LOCATE AND PROTECT ALL ELECTRICAL CONDUITS SERVING AREAS BEYOND THESCOPE OF WORK. PRIOR TO TRENCHING OR CUTTING, CONTRACTOR SHALL PRESENT PROPOSED ROUTE TOOWNERS REPRESENTATIVE, ENGINEER AND ARCHITECT FOR APPROVAL.
4. COORDINATE WITH OWNER AS TO WHAT EQUIPMENT & FINISH ITEMS ARE TO RE-USED SUCH ASRESTROOM FIXTURES AND ACCESSORIES, MOLDINGS, WAINSCOTS, TRIMS, INTERIOR DOORS, INTERIORGLAZING & ORNAMENTAL ITEMS, CAREFULLY REMOVE & SET-ASIDE FOR RE-USE.
5. WHERE PARTITIONS ARE BEING REMOVED, ALL ELECTRICAL DEVICES SHALL BE DISCONNECTED AND MADESAFE. WHEREVER EXISTING UTILITIES ARE TO BE CAPPED, REROUTED, REMAIN IN PLACE, OR TERMINATED,COORDINATE W/ MEP DWGS.
6. WHERE FLOOR AND WALL FINISHES ARE BEING REMOVED, ALL ADHESIVE RESIDUE, MECHANICALFASTENERS AND MISC. ITEMS SHALL ALSO BE REMOVED. ALL DEPRESSIONS / VOIDS CREATED IN THEEXISTING SLAB DUE TO REMOVAL OF EQUIPMENT SHALL BE FILLED ACCORDINGLY TO BRING THEM UPLEVEL AND FINISHED TO MATCH SURROUNDING FINISH SLAB.
7. REMOVE ALL ITEMS LOCATED ABOVE CEILING THAT IS NOT A PART OF THE PROPOSED WORK. COORDINATEWITH OWNER AS TO ANY ITEM THAT IS TO BE LEFT UNDISTURBED.
8. WHERE CUTTING OR DEMOLITION OF THE EXISTING BUILDING IS INDICATED OR REQUIRED TOACCOMMODATE NEW CONSTRUCTION, THE STRUCTURAL ENGINEER SHALL BE CONSULTED PRIOR TOBEGINNING OF TASK TO DETERMINE IF THIS WORK WILL IN ANY WAY UNDERMINE THE FOUNDATIONS ORCOMPROMISE THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING, AND TO DETERMINE A COURSE OFCORRECTIVE ACTION FOR RESTORING ANY DAMAGE AND RETURNING THE APPEARANCE TO ANACCEPTABLE LEVEL.
9. WHENEVER POSSIBLE, ALL CUTS IN MASONRY WALLS SHALL OCCUR AT JOINT LINES - COORDINATE WITHNEW CONSTRUCTION.
10. CONTRACTOR SHALL ADEQUATELY BRACE & SUPPORT STRUCTURE AS REQUIRED DURING DEMOLITIONPHASE. USE EXTREME CARE TO NOT DAMAGE SUPPORT BEAMS TO REMAIN.
11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF ALL DEMOLITION MATERIAL INCLUDING ANYEQUIPMENT THAT IS NOT TO BE REUSED.
12. MAINTAIN FIRE EGRESS AT ALL TIMES THROUGHOUT THE COURSE OF THIS WORK.
NORTH
02 POOL HOUSE DEMOLITION RCP3/16" = 1'-0"
0
2'
4'
8'
12'
FLOOR PLAN DEMOLITION NUMBERED NOTES
REMOVE TRELLIS STRUCTURE
REMOVE PLUMBING FIXTURE
REMOVE FLOOR FINISHES
REMOVE DOOR
REMOVE RESTROOM PARITIONS
REMOVE PORTION OF WALL TO ACCOMMODATE NEW RAMP
REMOVE PAVERS
REMOVE BOLLARDS TO BE REPLACED BY NEW WORK PLAN
1
2
3
4
5
RCP DEMOLITION NUMBERED NOTES
REMOVE LIGHT FIXTURE
REMOVE TRELLIS STRUCTURE
1
2
2
2
2
2 2
2 2
2
2
1 1
1
11
11
1
1
6
7
4'-212"5'-0"
8
8 8 8 8 8 8
8 8
POOL HOUSE DEMOPLAN AND RCP
A105
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
NORTH
02 FIRST FLOOR OVERALL RCP1/8" = 1'-0"
0
2'
4'
8'
16'
01A504
01A502
LOBBY100
LIBRARY102
DISCOVERYROOM
101
OFFICE104
OFFICE106
OFFICE107
OFFICE108
VESIBULE103
OFFICE105
OFFICE110
OFFICE109
OFFICE111
BREAKROOM112
HVAC113
HVAC114
ROTUNDA116
CORRIDOR115
MAILCORRIDOR
117
ELECTRICAL120
DINING ROOM121
MEN'S RESTROOM118
HVAC &ELECTRICAL
122
WOMEN'SRESTROOM
119
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUM BOARDDROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS, INSULATIONAND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
FIRST FLOOR OVERALLPLAN & RCP
A201
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUM BOARDDROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS, INSULATIONAND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
NORTH
01 SECOND FLOOR OVERALL PLAN1/8" = 1'-0"
0
2'
4'
8'
16'
WH
AUDITORIUM201
ARTS &CRAFTS
212
LOUNGE211
LOBBY200
FITCAMP202
SALON203
MEN'SRESTROOM
205 WOMEN'SRESTROOM
204
BILLIARDS206
CAFEDINING
207CAFE208
STORAGE210
OFFICE209
01A505
01A507
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
SECOND FLOOROVERALL PLAN
A202
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING
THIS WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FORACTUAL FINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, ANDTHE MECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUSLOCATIONS SHALL BE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALLTYPES, GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCEOVER SMALLER SCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALSTHAT VISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICALMATERIALS ARE UNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLEDPERFORMANCE WILL EQUAL OR SURPASS THAT OF EXISTING MATERIALS.
02A509
01A509
CORRIDORA100
DOCTOR'SOFFICE
A108
CHARTINGA110
THERAPYA111
NURSESOFFICE
A109
VESTIBULEA112
LOUNGEA103
MEDROOMA105
METER ROOMA104
OFFICEA107
EXISTINGRESTROOM
A106
MECH.A102
ELEVATORLOBBY
A101
CORRIDORA100
WHEELCHAIRSTORAGE
A113 DININGA114
EXISTINGRESTROOM
A112
EXISTINGKITCHEN
A115
AHU
AHU
AHU
NORTH
02 WING A OVERALL RCP3/32" = 1'-0"
0
4'
8'
16'
24'
TO MAIN BUILDING
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING
THIS WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FORACTUAL FINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLABUNLESS NOTED OTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, ANDTHE MECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALSTHAT VISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICALMATERIALS ARE UNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLEDPERFORMANCE WILL EQUAL OR SURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEENOPPOSITE WALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OFALL SUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALLGYPSUM BOARD DROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS,INSULATION AND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
01
01A510
CORRIDORA100
DOCTOR'SOFFICE
A108
CHARTINGA110
THERAPYA111
NURSESOFFICE
A109
VESTIBULEA112
LOUNGEA103
MEDROOMA105
METER ROOMA104
OFFICEA107
EXISTINGRESTROOM
A106
MECH.A102
ELEVATORLOBBY
A101
CORRIDORA100
WHEELCHAIRSTORAGE
A113DINING
A114
EXISTINGRESTROOM
A112
EXISTINGKITCHEN
A115
02A510
WING A OVERALL PLANA203
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS EFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUM BOARDDROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS, INSULATIONAND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
01
02A512
WING D OVERALL PLANA204
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
FLOOR PLAN NUMBERED NOTES
FURNITURE FOR REFERENCE ONLY, SEE FURNITURE SCHEDULES ON SHEET SERIES A704
NEW FREESTANDING GRILL BY XXXX
TV MOUNTED WITH BOTTOM OF SCREEN AT XX" AFF
EXISTING COLUMNS WRAPPED WITH FAUX WOOD FINISH
NEW OUTDOOR SHOWER HEAD
NEW BOLLARD LIGHTING
SIDEWALK TO LAKE CONTINUES, SEE LANDSCAPE PLANS NOT PART OF THIS SET.
1
2
3
4
4
4
4
4
44
4
4
4
2
11
1
1
1 1
1
1
5
5
8'-3
1 8"
04A301
02A301
04A301
01A301
03A301
A301
5'-0"14'-0"5'-0"
5'-0"14'-0"5'-0"
5'-0
"
5'-0
"
C-14
C-18
T-19T-19
T-18T-18
T-20
T-19T-19
T-19 T-19
C-14
C-14
C-14
C-14
C-14
C-14
C-18 C-18 C-18
C-18
C-18
C-18
C-18
C-16
C-17
C-17
C-18C-18 C-18C-18
6
6 6 6 6 6
66
6
C-16
C-16
C-16C-16
C-16
7
7 7
NORTH
02 POOL HOUSE RCP3/16" = 1'-0"
0
2'
4'
8'
12'
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUM BOARDDROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS, INSULATIONAND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
CEILING FIXTURE LEGEND
SURFACE MOUNTED LEDFIXTURE
FAN WITH LIGHT
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXHAUST FAN
*REF. MEP DWGS FOR SPECIFICATION AND DESCRIPTIONOF EACH ITEM
RCP NUMBERED NOTES
NEW GYPSUM CEILING, MATCH EXISTING HEIGHT1
EQ 9'-1034" EQ
EQ6'
-0"
EQEQ
EQ
EQ EQ
EQEQ
EQ EQ
6'-758" 6'-75
8"6'-758" 6'-75
8"
6'-758" 6'-75
8"6'-758" 6'-75
8"
1
11
06A301
POOL HOUSE PLANA205
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
EXISTING POOL
EXISTING HOTTUB
EXISTINGPLANTERS
C-13
T-19
U-1
C-13
C-13
T-19
U-1
C-13
C-13
T-19
U-1
C-13
C-13
T-19
U-1
C-13
C-18
T-19
C-18
C-18C-18
C-18
T-19
C-18
C-18C-18
C-13
T-19
U-1
C-13
C-13
T-19
U-1
C-13
C-13
T-19
U-1
C-13
C-13
T-19
U-1
C-13
POOL PLANA206
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
ELEVATION NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHEET WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. ALL PRE-MANUFACTURED TRIM, MOULDINGS, CLADDING & COMPONENTS SHALL BE FASTENED & ADHEREDTO BUILDING PER MANUFACTURER SPECIFICATIONS TO WITHSTAND DESIGN WIND PRESSURE IDENTIFIEDON STRUCTURAL DRAWINGS.
5. COORDINATE WITH ARCHITECT THE LOCATION OF ALL ADDITIONAL CONTROL JOINTS REQUIRED BUT NOTINDICATED ON PLANS.
6. ALL EXTERIOR SURFACES TO BE PAINTED IN FIELD OR BE PROVIDED WITH FACTORY OR SHOP APPLIEDFINISH AS REQUIRED. ALL COLORS SHALL BE SELECTED BY ARCHITECT, APPROVED BY OWNER.
01 EXTERIOR ELEVATION1/4" = 1'-0"
0
1'
2'
4'
8'02 EXTERIOR ELEVATION
1/4" = 1'-0"
0
1'
2'
4'
8'03 EXTERIOR ELEVATION
1/4" = 1'-0"
0
1'
2'
4'
8'
04 EXTERIOR ELEVATION1/4" = 1'-0"
0
1'
2'
4'
8'05 EXTERIOR ELEVATION
1/4" = 1'-0"
0
1'
2'
4'
8'
NEW FIREPLACEFINISH
OUTDOORTV
5'-8
1 2"
WOOD FRAMEDEXISTING BEAMS
06 EXTERIOR ELEVATION1/4" = 1'-0"
0
1'
2'
4'
8'
3'-4
7 8"
12:1 SLOPE3'-0
"CL
OF
HAN
DRA
IL
1'-0"
WOOD FRAMEDEXISTING BEAMS
WOOD FRAMEDEXISTING BEAMS
WOOD FRAMEDEXISTING BEAMS
WOOD FRAMEDEXISTING BEAMS
10'-1
13 16"
10'-1
13 16"
PAINTEDCONCRETEMANTLE CAP
NEW FIREPLACEFINISH
06 FIREPLACE FINISH DETAIL1/2" = 1'-0"
0
6"
1'
2'
4'
CT-2
CT-3
CT-4
4'-115 16
" O
R TO
NEX
T FU
LL T
ILE
5'-1
7 8" O
R TO
NEX
T FU
LL T
ILE
TO T
OP
OF
SHAF
T
4'-115 16
" O
R TO
NEX
T FU
LL T
ILE
5'-7
" O
R TO
NEX
T FU
LL T
ILE
TO T
OP
OF
SHAF
T
4'-5
5 16"
OR
TO N
EXT
FULL
TIL
E 5
'-91 4"
OR
TO N
EXT
FULL
TIL
ETO
TO
P O
F SH
AFT
EXTERIOR POOLHOUSE ELEVATIONS
A301
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
01
02
07
0504
08
06
10
11
09
13
###
14
17
19
18
16 15
A
A
11'-4
1 4"5'
-5"
6'-10
1 2"3'
-8"
2'-2
1 2"
1058"6'-67
8"6'-1118"4'-4"2'-0"8'-4"
7'-10
5 8"3'
-13 4"6'
-101 2"
135°
8'-918"6'-57
8"1'-3"
135°
8'-11
"9'
-03 4"
15'-5" 10'-4" 3'-378" 7'-111
8" 9'-0" 10'-078"
FLOOR PLAN NUMBERED NOTES
FURNITURE FOR REFERENCE ONLY, SEE FURNITURE SCHEDULES ON SHEET SERIES A704
RELOCATED ELECTRICAL POWER PANEL
TV MOUNTED WITH BOTTOM OF SCREEN AT 48" AFF
RELOCATED FIRE ACCESS PANEL
RELOCATED VENDING MACHINE
NEW CAROLINA (MODEL # MM-15472SCDZ) 24" STORAGE LOCKER WITH 2-Z DOORS FLAT TOP (10)
1
2
3
4
1 1
1
1
11
1
1
1
1
11
1
11
LOBBY100
LIBRARY102
DISCOVERYROOM
101
OFFICE104
OFFICE106
OFFICE107
OFFICE108 VESIBULE
103
OFFICE105
OFFICE110
OFFICE109
OFFICE111
BREAKROOM112
HVAC113
HVAC114
33
24
12
1'-378"
1'-35 8"
A A
A
A
AA
A AA
A
A
A
AA
A
AA
1'-65 8"
1'-61 2"
A
01A551
03A551
07A551
05A551
01A552
01A553
3'-3
3 4"
9'-038"7'-103
4"
2'-3
5 8"1'-
27 8"
C-1 C-1 C-1 C-1C-1 C-1 C-1 C-1
C-2 C-2C-2C-2
T-1 T-1
T-2
C-3
T-1 T-1
T-2
C-3
T-4
C-4
C-4
C-4
C-4
C-4
C-5
T-5
C-4C-4
C-5
T-5T-5
T-5
T-5T-5
C-5
T-5
T-5
T-5
T-5
C-5
C-5C-5
T-5
T-5
T-5
C-5
C-5C-4 C-4
C-4
C-4
T-6
C-5
B-1B-1
B-1
B-1
5
6
6
6
5
T-4
C-4
C-4
C-4
C-4
ENLARGED FIRSTFLOOR PLAN
A501
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUM BOARDDROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS, INSULATIONAND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
CEILING FIXTURE LEGEND
LAY-IN LED FIXTURE
RECESSED LED DOWNLIGHT
PENDANT LIGHT FIXTURE
WALL SCONCE LIGHT FIXTURE
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXHAUST FAN
*REF. MEP DWGS FOR SPECIFICATION AND DESCRIPTIONOF EACH ITEM
+9'-0"B/ACT
RCP NUMBERED NOTES
NEW GYPSUM CEILING, MATCH EXISTING HEIGHT1
+9'-0"B/ACT
+9'-0"B/ACT
+9'-0"B/ACT
+9'-0"B/ACT
+9'-0"B/ACT
+9'-0"B/ACT
+9'-0"B/ACT
+9'-0"B/ACT
+9'-0"B/ACT
11
1
LOBBY100
LIBRARY102
DISCOVERYROOM
101
OFFICE104
OFFICE106OFFICE
107
OFFICE108
VESIBULE103
OFFICE105
OFFICE110
OFFICE109OFFICE
111
BREAKROOM112
HVAC113
HVAC114
+9'-10"B/GYP
+9'-10"B/GYP
+9'-10"B/GYP
+9'-10"B/GYP
CHANDELIER LIGHT FIXTURE
1
+9'-10"B/GYP
ENLARGED FIRSTFLOOR RCP
A502
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
17
21
16
14
15
23
13
20
2724
2526
29
28
31 30
1
1
1
1
HVAC114
ROTUNDA116
CORRIDOR115
MAILCORRIDOR
117
ELECTRICAL120
DINING ROOM121
MEN'S RESTROOM118
HVAC &ELECTRICAL
122
WOMEN'SRESTROOM
119
5'-5
"
7'-914" 5'-0" 13'-23
4"
5'-5
"
5'-5 78 "
10'-9
"
15'-3"
8'-418"
2'-2 12 "
15'-7
"
7'-3 18 "
03A601
D
D
C
FLOOR PLAN NUMBERED NOTES
FURNITURE FOR REFERENCE ONLY, SEE FURNITURE SCHEDULES ON SHEET SERIES A704
RELOCATED ELECTRICAL POWER PANEL
TV MOUNTED WITH BOTTOM OF SCREEN AT 48" AFF
RELOCATED FIRE ACCESS PANEL
PT-2 ACCENT COLOR AT WAINSCOT BELOW CHAIR RAIL
1
2
3
4
05A552
07A552
22
A
A
A
T-8
T-7
T-8T-10
T-9
T-9T-9
T-9
T-10
T-10
T-10
T-9T-9
T-9
T-10 T-10
T-11 T-11
T-11 T-11
T-11T-11
T-11
T-11
T-12
C-6
C-6C-6
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7C-7
C-7
C-7C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7C-7 C-7 C-7 C-7
C-7
C-7
C-7
C-7 C-7 C-7C-7
C-7
C-7
C-7 C-7C-7 C-7
C-7
C-7
C-7C-7C-7
C-7
C-7
C-7
C-7
C-7
C-7 C-7
C-7
C-7
C-7
C-8
C-8
C-8
C-8
C-8C-8
C-8C-8
C-8C-8
5
5
5
5
5
5
5
LVT-1
LVT-1
33
T-21
ENLARGED FIRSTFLOOR PLAN
A503
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUM BOARDDROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS, INSULATIONAND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
HVAC114
ROTUNDA116
CORRIDOR115
MAILCORRIDOR
117
ELECTRICAL120
DINING ROOM121
MEN'S RESTROOM118
HVAC &ELECTRICAL
122
WOMEN'SRESTROOM
119
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-10"B/GYP
CEILING FIXTURE LEGEND
LAY-IN LED FIXTURE
RECESSED LED DOWNLIGHT
PENDANT LIGHT FIXTURE
WALL SCONCE LIGHT FIXTURE
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXHAUST FAN
*REF. MEP DWGS FOR SPECIFICATION AND DESCRIPTIONOF EACH ITEM
RCP NUMBERED NOTES
NEW GYPSUM CEILING, MATCH EXISTING HEIGHT1
CHANDELIER LIGHT FIXTURE
1
+9'-10"B/GYP
+9'-2"B/SOFFIT
+9'-10"B/GYP
+9'-2"B/SOFFIT
01A601
ENLARGED FIRSTFLOOR RCP
A504
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
FLOOR PLAN NUMBERED NOTES
FURNITURE FOR REFERENCE ONLY, SEE FURNITURE SCHEDULES ON SHEET SERIES A704
TV MOUNTED WITH BOTTOM OF SCREEN AT 48" AFF
1
2
1
1
1
A
A
T-13
T-14 T-14
T-14
T-14
T-13
C-9
C-10C-10
C-10
C-10
C-10
C-10
C-9
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
T-15
T-15
1'-61 2"
2'-71 2"
1'-23
4
"
1'-234" 9'-61
2"
912"
6'-412"
1'-858"
C-19
C-19
C-19
C-19
C-19
C-19
C-19
C-19
C-19
C-19
C-19
C-19
CPT-1
LVT-1 LVT-1
LVT-1
34'-1034"
34'-1034"
16'-6
1 2"
16'-1
03 4"
4'-5
7 8"
4'-3
3 4"4'
-33 4"
4'-334" 4'-57
8"
4'-5
7 8"
4'-578"4'-33
4"
EQUIPMENT INTHIS AREA PERHUR DESIGN
THIS
WAL
L TO
REC
EIVE
FU
LL L
ENG
TH M
IRRO
R
SECOND FLOORENLARGED PLAN
A505
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUM BOARDDROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS, INSULATIONAND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
CEILING FIXTURE LEGEND
LAY-IN LED FIXTURE
RECESSED LED DOWNLIGHT
PENDANT LIGHT FIXTURE
WALL SCONCE LIGHT FIXTURE
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXHAUST FAN
*REF. MEP DWGS FOR SPECIFICATION AND DESCRIPTIONOF EACH ITEM
RCP NUMBERED NOTES
NEW GYPSUM CEILING, MATCH EXISTING HEIGHT1
CHANDELIER LIGHT FIXTURE
MATCH EXISTINGB/ ACT
SECOND FLOORENLARGED RCP
A506
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
FLOOR PLAN NUMBERED NOTES
FURNITURE FOR REFERENCE ONLY, SEE FURNITURE SCHEDULES ON SHEET SERIES A704
TV MOUNTED WITH BOTTOM OF SCREEN AT 48" AFF
1
2
E
A
A
A
A
E
36
50
51
52
T-15
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
T-16
C-7 C-7
C-7
C-7C-7 C-7C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
T-17
T-17
C-20 C-20
C-20
C-20 C-20
C-20
C-11
C-11
C-11
C-12
C-12
C-12
C-12C-12
C-12
10'-0 38 "
2'-11
1 2"
10'-2 78 "
4'-8"
5'-8 38 "
4'-938"
C-5
T-5
C-4
12'-10 14 "
T-15
T-15
T-16
T-16
T-16
T-16
CPT-1
15'-9"EVEN BETWEEN COLUMNS
39'-4
1 2"EV
EN B
ETW
EEN
CO
LUM
NS
15'-2
3 8"
1'-6 14 "
CPT-1
LVT-1
SECOND FLOORENLARGED PLAN
A507
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUM BOARDDROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS, INSULATIONAND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
CEILING FIXTURE LEGEND
LAY-IN LED FIXTURE
RECESSED LED DOWNLIGHT
PENDANT LIGHT FIXTURE
WALL SCONCE LIGHT FIXTURE
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXHAUST FAN
*REF. MEP DWGS FOR SPECIFICATION AND DESCRIPTIONOF EACH ITEM
CHANDELIER LIGHT FIXTURE
04A601
SECOND FLOORENLARGED RCP
A508
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
02 ENLARGED WING A LOUNGE AND OFFICES PLAN3/16" = 1'-0"
0
2'
4'
8'
12'
DOCTOR'SOFFICE
A108
CHARTINGA110
THERAPYA111
NURSESOFFICE
A109
VESTIBULEA112
LOUNGEA103
MEDROOMA105
METER ROOMA104
OFFICEA107
EXISTINGRESTROOM
A106
MECH.A102
ELEVATORLOBBY
A101
CORRIDORA100
WHEELCHAIRSTORAGE
A113
DININGA114
EXISTINGRESTROOM
A112
EXISTINGKITCHEN
A115
A
A
A
11'-5
3 16"
12'-012"
MATCH EXISTING
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
2'-212"
6'-2
1 2"
A
05A553
5655
53
54 57
63
62
61
60
59
64
65
67
66
70
69
68
07A553
58
T-10
C-7
T-9 T-9
T-9T-9
T-9
T-9 T-9
T-9
T-9T-9
T-10
T-10
T-10
C-7C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7C-7
C-7
C-7
C-7C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7C-7
C-7
C-7C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
T-14
T-13
C-9
C-10
C-10
T-14
C-9C-10
C-10
C-10
C-10 C-10 C-10
C-10 C-10
T-13 C-9
T-14
T-14
C-7
A
ENLARGED WING APLANS
A509
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
02 ENLARGED WING A LOUNGE AND OFFICES RCP3/16" = 1'-0"
0
2'
4'
8'
12'
AHU
AHU AHU
DOCTOR'SOFFICE
A108
CHARTINGA110
THERAPYA111
NURSESOFFICE
A109
VESTIBULEA112
LOUNGEA103
MEDROOMA105
METER ROOMA104
OFFICEA107
EXISTINGRESTROOM
A106
MECH.A102
ELEVATORLOBBY
A101
CORRIDORA100
WHEELCHAIRSTORAGE
A113
DININGA114
EXISTINGRESTROOM
A112
EXISTINGKITCHEN
A115
3'-2
1 2"
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUALOR SURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUMBOARD DROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS,INSULATION AND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
CEILING FIXTURE LEGEND
NEW LAY-IN LEDFIXTURE
NEW RECESSED FLUORESCENTDOWNLIGHT
NEW LED WALL SCONCE LIGHTFIXTURE
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXHAUST FAN
*REF. MEP DWGS FOR SPECIFICATION AND DESCRIPTIONOF EACH ITEM
MATCH EXISTINGB/GYP
MATCH EXISTINGB/GYP
ENLARGED WING ARCPS
A510
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
CORRIDORD100
DININGD102
EXISTINGRESTROOM
D103
EXISTINGKITCHEN
D104
A
A
C
6'-4
1 2"
6'-412"
2'-2
1 2"
71
72
73
74
75
76
77
T-10
C-7
C-7
C-7
T-10
T-10
T-10
T-10
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
T-9
T-9
T-9
T-9
T-9
T-9
T-9
T-9
C-7C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
C-7
AHU
AHU
NORTH
02 ENLARGED WING D DINING ROOM RCP3/16" = 1'-0"
0
2'
4'
8'
12'
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUALOR SURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUMBOARD DROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS,INSULATION AND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
CORRIDORD100
DININGD102
EXISTINGRESTROOM
D103
EXISTINGKITCHEN
D104
CEILING FIXTURE LEGEND
NEW LAY-IN LEDFIXTURE
NEW RECESSED FLUORESCENTDOWNLIGHT
NEW LED WALL SCONCE LIGHTFIXTURE
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXHAUST FAN
*REF. MEP DWGS FOR SPECIFICATION AND DESCRIPTIONOF EACH ITEM
MATCH EXISTINGB/GYP
MATCH EXISTINGB/GYP
ENLARGED WING DPLAN & RCP
A511
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
LOUNGE ANDOFFICE AREA TO
BE FIELDVERIFIED. AREA
TO RECEIVE NEWFINISHES ANDFURNITURE.
LOUNGE ANDOFFICE AREA TO
BE FIELDVERIFIED. AREA
TO RECEIVE NEWFINISHES ANDFURNITURE.
OFFICES & LOUNGED105
OFFICES & LOUNGED106
NORTH
01 ENLARGED WING D PLAN3/16" = 1'-0"
0
2'
4'
8'
12'
CEILING PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION. ALL CEILING ELEVATION FINISHES ARE FROM TOP OF SLAB UNLESS NOTEDOTHERWISE.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR FINISH SCHEDULE.
6. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUALOR SURPASS THAT OF EXISTING MATERIALS.
7. LOCATION OF CEILING GRID AND TILES ARE REFERENCED FROM EQUAL DISTANCE BETWEEN OPPOSITEWALLS. U.N.O.
8. GYPSUM BOARD CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLATION OF ALLSUPPLEMENTAL AND MISCELLANEOUS ITEMS REQUIRED TO ADEQUATELY SUPPORT ALL GYPSUMBOARD DROPS, SOFFITS, CORNICES, ECT. FROM STRUCTURE ABOVE.
9. ALL FINISH CEILING MATERIALS SHALL BE INSTALLED AFTER UTILITIES, HANGARS, SUPPORTS,INSULATION AND MISC. INTERSTITIAL ITEMS ARE INSTALLED.
CEILING FIXTURE LEGEND
NEW LAY-IN LEDFIXTURE
NEW RECESSED FLUORESCENTDOWNLIGHT
NEW LED WALL SCONCE LIGHTFIXTURE
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXHAUST FAN
*REF. MEP DWGS FOR SPECIFICATION AND DESCRIPTIONOF EACH ITEM
LOUNGE ANDOFFICE AREA TO
BE FIELDVERIFIED. AREA
TO RECEIVE NEWFINISHES ANDFURNITURE.
LOUNGE ANDOFFICE AREA TO
BE FIELDVERIFIED. AREA
TO RECEIVE NEWFINISHES ANDFURNITURE.
OFFICES & LOUNGED105
OFFICES & LOUNGED106
NORTH
02 ENLARGED WING D RCP3/16" = 1'-0"
0
2'
4'
8'
12'
ENLARGED WING DPLAN & RCP
A512
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
FLOOR PLAN NOTES1. REFERENCE SHEET A-001 FOR GENERAL CONDITIONS AND ADDITIONAL REQUIREMENTS AFFECTING THIS
WORK.
2. FINISH FLOOR DATUM (REFERENCE) = 0'-0" IS TO TOP OF SLAB. REFER TO CIVIL DRAWINGS FOR ACTUALFINISH FLOOR ELEVATION.
3. CONTRACTOR SHALL COORDINATE ALL WORK ON THIS SHT. WITH THE DEMOLITION WORK, AND THEMECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL AND FIRE PROTECTION DRAWINGS.
4. EXISTING CONDITIONS NOT PART OF THIS PERMIT SHOWN LIGHTER.
5. REFERENCE THE A-700 SERIES SHEETS FOR DOOR, GLAZING AND FINISH SCHEDULES.
6. WINDOWS WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
7. ALL GYPSUM BOARD IN CORRIDORS SHALL BE HUNG VERTICALLY.
8. REFER TO ENLARGED PLANS FOR ADDITIONAL INFO. INCLUDING DIMENSIONS, DOOR TAGS, WALL TYPES,GLAZING LAYOUT, AND CONSTRUCTION DETAILS. ENLARGED PLANS TAKE PRECEDENCE OVER SMALLERSCALE DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING.
9. USE MATERIALS IDENTICAL TO EXISTING MATERIALS. FOR EXPOSED SURFACES, USE MATERIALS THATVISUALLY MATCH EXISTING ADJACENT SURFACES INSOFAR AS POSSIBLE. IF IDENTICAL MATERIALS AREUNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE WILL EQUAL ORSURPASS THAT OF EXISTING MATERIALS.
C-9
C-10 C-10
CPT-1LVT-1CPT-2
TRANSITION,TYPICAL IL
TRANSITION,TYPICAL IL
LVT IN FRONT OF RESIDENTENTRY AT ALL IL BUILDINGS.CARPET THROUGHOUT ALLAL-BUILDING CORRIDORS
CPT INHALLWAYS
03A552
TYPICAL ELEVATORLOBBY PLAN
A555
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
TOILET ACCESSORY LEGENDBASIS OF DESIGN: 'BOBRICK' OR 'BRADLEY' WASHROOM ACCESSORIES
18"W X 30"H FIXED POSITION TILT MIRRORB-293 1830
2
3
TOILET ACCESSORIES SHOWN ARE BASIS OF DESIGN ONLY, FOR BUDGETINGPURPOSES. CONTRACTOR MUST COORDINATE DIRECTLY WITH OWNER FORTYPE AND STYLE PRIOR TO ORDERING. ACCESSORIES MUST BE INACCORDANCE WITH ALL APPLICABLE ADA REQUIREMENTS.
TOILET FIXTURE & ACCESSORIES KEYED NOTES
THE HIGHEST OPERABLE PART OF DISPENSERS AND RECEPTACLES SHALL BE NO GREATER THAN 48"ABOVE FINISH FLOOR.
MIRRORS SHALL BE MOUNTED WITH BOTTOM EDGE OF THE REFLECTING SURFACE NO HIGHER THAN40" ABOVE FINISH FLOOR.
LAVATORIES SHALL BE MOUNTED WITH THE RIM OR COUNTER TOP NO HIGHER THAN 34" ABOVE FINISHFLOOR. PROVIDE A CLEARANCE OF AT LEAST 29" ABOVE FINISH FLOOR TO THE BOTTOM OF THE APRON.
THE DIAMETER OF THE GRIPPING SURFACE OF THE GRAB BAR SHALL BE 1 1/4"Ø TO 1 1/2"Ø. THE GRABBAR SHALL HAVE A 1 1/2" CLEARANCE FROM THE WALL. THE LENGTH OF THE GRAB BARS ARE ASSHOWN.THE HEIGHT OF HANDICAPPED WATER CLOSETS SHALL BE 17"-19" MEASURED TO THE TOP OF THETOILET SEAT ABOVE FINISH FLOOR AND SHALL HAVE AN 18" CLEARANCE ON EACH SIDE FROM CENTERLINE OF WATER CLOSET. FLUSH CONTROL MUST BE MOUNTED ON THE WIDE SIDE OF TOILET NO MORETHAN 44" HIGH.
THE TOILET PAPER DISPENSER SHALL BE MOUNTED SO THAT THE DISPENSING HEIGHT OF THE PAPERSHALL HAVE A CLEARANCE OF NOT LESS THAN 15" AND NO MORE THAN 48" FROM THE FINISH FLOORAND THE CENTER LINE BETWEEN 7" AND 9" FROM THE FRONT EDGE OF THE TOILET.
1. CONTRACTOR TO PROVIDE TOILET SIGNAGE TO COMPLY WITH ADA, AND IBC 2017 FOR BUILDINGCONSTRUCTION AND LOCAL ORDINANCES & REQUIREMENTS. ADA SIGN SHALL BE INSTALLED ON THE WALLADJACENT TO THE LATCH SIDE OF THE DOOR. MOUNTING HEIGHT SHALL BE 60" A.F.F.
2. HOT WATER & DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED. THERE SHALL BE NO SHARP ORABRASIVE SURFACES UNDER LAVATORIES.
3. PROVIDE ALL STRUCTURAL BACKING TO BRACE TOILET ACCESSORIES AND EQUIPMENT.
4. DIMENSIONS ARE FROM FINISH SURFACE.
GENERAL TOILET FIXTURE & ACCESSORIES NOTES
SURFACE MOUNTED TOILET TISSUE DISPENSER FOR SINGLE ROLLB-685
STAINLESS STEEL GRAB BAR 1-1/2" DIAMETERB-6806 X 42 B-6806 X 36
F
D
E
C
B
A
BC
D
AB
C
3
TEAK BENCHES. SEEFURNITURESCHEDULE
NOTE: DIMENSIONS ON THE SHEET TO FINISH FACE OF WALLS.
03 WOMENS RESTROOM1/2" = 1'-0"
0
6"
1'
2'
4'
45
4 SURFACE MOUNTED PAPER TOWEL DISPENSERB-359039
5 SURFACE MOUNTED SOAP DISPENSERB-2111
1'-6"
2'-11
"
11'-0
"
10'-9"
2'-10
" 3'-6
"
2'-0"1'-0"
C L
6"
1'-6"
D
E
03 WOMENS RESTROOM1/2" = 1'-0"
0
6"
1'
2'
4'
A
BCD
CT-1
TEAK BENCHES. SEEFURNITURESCHEDULE
3'-4
"
2'-10
"
1
BCCT-1
5'-10"
TEAK BENCHES. SEEFURNITURESCHEDULE
TEAK BENCHES. SEEFURNITURESCHEDULE
2'-0" 1'-0"
C L
6"
1'-6"
E
CT-1D
5'-10"
CT-1
CT-1CT-1
CT-1
CT-1
ENLARGED RESTROOMPLANS & ELEVATIONS
A556
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
EACH LOCKER UNIT CONTAINS 20 LOCKEDMAILBOXES AND 2 PARCEL LOCKERS
8 TOWERS160 MAILBOXES16 PARCEL LOCKERS
DETAILSA601
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
GENERAL DOOR SCHEDULE NOTES:1. EXIT DOORS SHALL BE OPERATIONAL FROM THE INSIDE WITHOUT USE OF A KEY, TOOL, SPECIAL KNOWLEDGE
OR EFFORT. DEVICES SHALL BE CAPABLE OF OPERATING WITH ONE HAND AND SHALL NOT REQUIRE TIGHTGRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. HARDWARE REQUIRED FORACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NO HIGHER THAN 48 INCHES ABOVE FINISH FLOOR.
2. DOOR CLOSERS TO BE SET AT MAXIMUM OF 5 LBF.
3. THRESHOLDS: CHANGES IN LEVEL GREATER THAN 1/4" IN HEIGHT AND NOT MORE THAN 1/2" MAX. IN HEIGHTSHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2.
4. DOOR HARDWARE SHALL BE MOUNTED BETWEEN 36" AND 42" ABOVE FLOOR AND BE LEVER TYPE.
5. ALL HARDWARE WILL BE "SCHLAGE" WITH A SATIN CHROME FINISH, UNLESS OTHERWISE NOTED.
6. THE MAIN EXIT DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED LOCKING DEVICES ROM THEEGRESS SIDE PROVIDED THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED. A READILY VISIBLEDURABLE SIGN SHALL BE POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: "THISDOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1 INCH HIGHON A CONTRASTING BACKGROUND.
GLAZING NOTES:1. ALL GLASS & GLAZING SHALL COMPLY WITH CHAPTER 54 OF THE U.S. CONSUMER PRODUCT SAFETY
COMMISSION SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS (16-CFR PART 1201).
2. ALL GLAZING, GLAZING SYSTEMS, COMPONENTS & CLADDING SHALL MEET THE DESIGN WIND PRESSURESSPECIFIED IN COMPLIANCE WITH FBC 16.06.16.1 WINDOW & DOOR MANUFACTURERS TEST REPORTS &INSTALLATION DETAILS SHALL BE INCLUDED AS PART OF PERMIT SUBMITTAL. SUBMIT SHOP DRAWINGS OFALL DOORS, GLAZING & HARDWARE FOR REVIEW.
3. ALL GLAZING WITHIN 24" OF DOOR SHALL BE SAFETY GLASS. ALL GLAZING IN HAZARDOUS LOCATIONS SHALLBE TEMPERED FOR IMPACT RESISTANCE.
HARDWARE GROUPS
HARDWARE GROUP D (POCKET DOOR)· JOHNSON HARDWARE POCKET DOOR 1500SC
SEIRES SOFT CLOSE POCKET DOOR FRAME KIT· SHLAGE POCKET DOOR PULL
DO
OR
#
DO
OR
THIC
KNES
S
DO
OR
TYPE
DO
OR
MAT
ERIA
L
FRAM
ETY
PE
FRAM
EM
ATER
IAL
DO
OR
WID
TH
DO
OR
HEI
GH
T
COMMENTS
MATERIALS AND FINISHESDOOR SCHEDULE
DO
OR
FIN
ISH
FRAM
EFI
NIS
H
01
03
HAR
DW
ARE
TYPE
04
02
05060708091011
1314
12
15161718192021
2324
22
25262728293031
3334
32
35363738394041
4344
42
45464748495051
5354
52
55565758596061
6364
62
65666768697071
7374
72
75767778798081
EXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAIN
EXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAIN
EXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAIN
EXISTING TO REMAINEXISTING TO REMAINEXISTING TO REMAIN
5/8" GYPSUM WALL BOARD(WATER RESISTANT GWB TO BE USED INRESTROOMS OR WITHIN 24" OFPLUMBING FIXTURES)
SUSPENDED CEILING GRIDW/ACOUSTICAL TILES OR GWB WHERESCHEDULED (SEE CEILING PLAN ANDDETAILS)
EXTEND KICKERS TO DECK EVERY 48"AND AT WALL TERMINATION
BASE BOARD TRIM AS SCHEDULED (SEEINTERIOR ELEVATIONS, FINISH PLANAND SCHEDULES
6" 20ga. METAL STUDS @ 16" O.C.
5/8" GYPSUM WALL BOARD(WATER RESISTANT GWB TO BE USED INRESTROOMS OR WITHIN 24" OFPLUMBING FIXTURES)
BASE BOARD TRIM AS SCHEDULED (SEEINTERIOR ELEVATIONS, FINISH PLANAND SCHEDULES
3-5/8" 20ga. METAL STUDS @ 16" O.C.
SUSPENDED CEILING GRIDW/ACOUSTICAL TILES OR GWB WHERESCHEDULED (SEE CEILING PLA N ANDDETAILS)
SOUND BATT INSULATION
SOUND BATT INSULATION
EXTEND KICKERS TO DECK EVERY 48"AND AT WALL TERMINATION
C
BA
5/8" GYPSUM WALLBOARD
EX'G WALLCONSTRUCTION
CONTINUE TO DECK
BLOCKING @ 8'
BASE BOARD TRIM AS SCHEDULED (SEEINTERIOR ELEVATIONS, FINISH PLANAND SCHEDULES
3-5/8" 20ga. METAL STUDS @ 16" O.C.
SOUND BATT INSULATION
03 WALL DETAILS1" = 1'-0"
0
3"
6"
1'
2'
D
5/8" GYPSUM WALLBOARD
BASE BOARD TRIM AS SCHEDULED (SEEINTERIOR ELEVATIONS, FINISH PLANAND SCHEDULES
3-5/8" 20ga. METAL STUDS @ 16"O.C.SOUND BATT INSULATION
BLOCKING AS REQUIRED
SOLID SURFACE CAP ASSCHEUDLED
6" INPRO CHAIR RAIL ASSCHEDULED+3'-0"
CL/CHAIR RAIL
E
5/8" GYPSUM WALLBOARD
BASE BOARD TRIM AS SCHEDULED (SEEINTERIOR ELEVATIONS, FINISH PLANAND SCHEDULES
3-5/8" 20ga. METAL STUDS @ 16"O.C.SOUND BATT INSULATION
BLOCKING AS REQUIRED
HEIGHT AS INDICATEDON INTERIORELEVATIONS
6"6"
GYP BOARD
HOLLOW METALFRAME
SEALANT @PERIMETER, MATCHFRAME COLOR
DOOR
H1
J1
GYP BOARD
HOLLOW METALFRAME
SEALANT @PERIMETER, MATCHFRAME COLOR
DOOR
H2
J2
0
1"
2"
4"
8"
12"04 HEAD/JAMB DETAILS
3" = 1'-0"
HOLLOW METALFRAME
DOOR
HOLLOW METALFRAME
DOOR
GYP BOARD
SEALANT @PERIMETER, MATCHFRAME COLOR
GYP BOARD
SEALANT @PERIMETER, MATCHFRAME COLOR
DOOR SCHEDULE &WALL DETAILS
A701
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
ESPRESSOOUTER CHAIR PANELS: ARTISAN- 65067 CHIFFONSEAT BACK AND CUSHION: BATIK- 65890 IMPERIAL
SPARE NUMBER
4
2
0
2
12
1
1
0
25
15
8
1
4
8
5
5
2
2
16
1
8
4
2
17
39
3
6
16
8
6
20
16
10
3
204
10
2
74
1
4
0
6
0
2
8
8
2
0
FURNITURE SCHEDULE
A703
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433
GENERAL FINISH NOTES:1. ALL FINISHES MUST BE SUBMITTED TO OWNER AND DESIGNER FOR APPROVAL PRIOR TO PURCHASE
AND/OR INSTALLATION.
2. USE COORDINATED, TINTED PRIMER THROUGH-OUT
3. PAINT COLORS BY OWNER
4. ALL PAINTED SURFACES TO RECEIVE ONE COAT PRIMER & TWO COATS OF FINISH PAINT MINIMUM. "ALLEXTERIOR, INTERIOR AND DEMISING WALLS SHALL BE METAL FRAMED. SHEETROCKED, FIREPROOFED ASREQUIRED BY CODE, FINISHED, TAPED AND SANDED SMOOTH. PRIMED AND READY FOR PAINTCONDITION." PER LANDLORD'S WORK DESCRIPTION
5. CONCRETE FLOORS TO BE PROTECTED DURING ALL PHASES OF CONSTRUCTION. MINIMIZE DAMAGE ANDSAW CUTS TO ENSURE THE FINAL APPEARANCE OF A SMOOTH, CONCRETE FINISH.
INTERIOR FINISH LEGENDSYMBOL MATERIAL MNFCTR SPEC NOTES
PT-1 PAINT SHERWINWILLIAMS
DIMENSIONS
NOTE:1. ALL WALL, FLOOR, AND CEILING FINISHES SHALL COMPLY WITH NFPA 101 SECTION 10.22. ALL QUESTIONS REGARDING FINISH LOCATIONS MUST BE ASKED BEFORE PROCEEDING.3. FINISHES ARE FOR PRICING PURPOSES ONLY. FINISHES HAVE NO BEEN SEEN OR APPROVED BY TENANT AT THIS
TIME. BEFORE PROCEEDING, CONFIRMATION OF APPROVAL MUST BE GIVEN AND ALL FINISHES MUST MEETMINIMUM CODE REQUIREMENTS.
4. LEVEL 4 FINISH AT WALLS THROUGHOUT.5. ALL PAINED SURFACES TO RECEIVE ONE COAT PRIMER & TWO COATS OF FINISH PAINT MINIMUM.6. INTERIOR WALL AND CEILING FINISH SHALL BE AS FOLLOWS (FBC T.803.9 UNSPRINKLERED)
a)EXIT ENCLOSURES AND EXIT PASSAGEWAYS: CLASS Ab)CORRIDORS: CLASS Bc)ROOMS AND OCCUPIED SPACES: CLASS Cd)INTEIROR FLOOR FINISH (FBC 804.2): CLASS I & IIe)BASE (FBC 806.6): CLASS II
PT-2 PAINT
LVT-1 LUXURY VINYL TILE SHAW QUIET COVERTIMBER
CPT-2
SHERWINWILLIAMS
LAM-1 PLASTIC LAMINATE FORMICA
SS-1 SOLID SURFACE CORIAN
6"
CPT-1 CARPET GATHER BATIK TILE, TIMELESS
SW 7604 SMOKY BLUE
SW 7005 PURE WHITE
WB-1
WP-1
WALL BASE
WALL PROTECTION
JOHNSONITE
INPRO
SHAW
CARPET SHAW
TBD
PALLADIUMDESIGNER WHITE
LINEN, TIMELESS
PLANKED COFFEE OAK
GLACIER WHITE
FIRST FLOOR FINISH SCHEDULE
ROOM # ROOM NAME FLOORINGWALLS
CEILINGMILLWORK
VERTICAL HORIZONTAL
100 LOBBY
104 OFFICE
106 OFFICE
107 OFFICE
108 OFFICE
109
110
111
112 BREAKROOM
113 HVAC
114 HVAC
115 CORRIDOR
116 ROTUNDA
117 CORRIDOR
118
119 WOMEN'SRESTROOM
CT-1 CERAMIC TILE DALTILE INDUSTRIAL PARK, LIGHT GREY
MAIN WALLS ACCENT WALL
LVT-1 LAM-1 SS-1PT-1 PT-2 GYP-1/PT-3
RUB-1 RUBBER FLOOR ECORE BURNISHED NICKEL
120
MEN'SRESTROOM
6" x 6"
12" x 12"
PT-3 PAINT SW 7007CEILING BRIGHT WHITE
SHERWINWILLIAMS
INSIDE AND OUTSIDECORNER PIECES TO BE USED
105 OFFICE
101DISCOVERY
ROOM CPT-2
103 VESTIBULE LVT-1
ACT-1 LAY IN ACOUSTICALTILE CALLAARMSTRONG
GYP-1 GYPSUM CEILNIG TBDTBD
121 DINING ROOM
200 LOBBY
201 AUDITORIUM
202 FITCAMP
203 SALON
204 WOMEN'SRESTROOM
205 MEN'SRESTROOM
206 BILLIARDS
207 CAFE DINING
208 CAFE
209 OFFICE
210 STORAGE
211 LOUNGE
212 ARTS ANDCRAFTS
A100 CORRIDOR
A101 ELEVATOR LOBBY
A102 MECHANICAL
A103 LOUNGE
A104 METER ROOM
A105 MED ROOM
A106 EXISTINGRESTROOM
A107 OFFICE
A108 DOCTOR'S OFFICE
A109 NURSES OFFICE
A110 CHARTING
A111 THERAPY
A112
A113 WHEELCHAIRSTORAGE
A114 DINING
A115 EXISTINGKITCHEN
D100 CORRIDOR
D101 ELEVATOR LOBBY
D102 DINING
D103 EXISTINGRESTROOM
D104 EXISTING KITCHEN
--
100 GRILL AREA &CABANAS
104
WOMEN'SRESTROOM
101 LOUNGE AREA
103
MEN'SRESTROOM
BASE PROTECTION
WB-1 WP-1
PT-1 PT-2 WB-1 WP-1 LAM-1 SS-1GYP-1/PT-3
ROOM # ROOM NAME FLOORINGWALLS
CEILINGMILLWORK
VERTICAL HORIZONTALMAIN WALLS ACCENT WALL BASE PROTECTION
ROOM # ROOM NAME FLOORINGWALLS
CEILINGMILLWORK
VERTICAL HORIZONTALMAIN WALLS ACCENT WALL BASE PROTECTION
ROOM # ROOM NAME FLOORINGWALLS
CEILINGMILLWORK
VERTICAL HORIZONTALMAIN WALLS ACCENT WALL BASE PROTECTION
ROOM # ROOM NAME FLOORINGWALLS
CEILINGMILLWORK
VERTICAL HORIZONTALMAIN WALLS ACCENT WALL BASE PROTECTION
WP-2 WALL PROTECTION INPRO PALLADIUM, RIGID SHEETDESIGNER WHITE
WP-1
D105
D106
OFFICES &LOUNGE
OFFICES &LOUNGE
CT-1 -- --GYP-1/PT-3--PT-1 -- WB-1
CT-1 -- --GYP-1/PT-3--PT-1 -- WB-1
FINISH LEGEND &SCHEDULE
A704
COPYRIGHT STATEMENT
These documents, their contents, and theideas, designs, and concepts presentedhere-in are the property of ELEVEN18Architecture and are issued only for thespecific project noted on thesedocuments. Holders of these documentsthat have established a mutually agreedcontractual relationship with ELEVEN18Architecture have been granted a limitedlicense to reproduce these documents inrelationship to the specific projectreferenced. All others are subject to USCopyright Law as defined by Title 17 of theUnited States Code and other regionallaws as may apply. Any revisions,reproductions, modifications, or re-use ofthese documents without the expresswritten consent of ELEVEN18 Architectureis prohibited by Law.
REVISIONS# DATE DESC.
PROJECT NAME:
VERANDACLUB6061 PALMETTO CIRCLE N.BOCA RATON, FL 33433