Top Banner
BOOSTER FANS AIRFLOW SENSORS AND LINT TRAPS VENTILATION SOLUTIONS FOR THE LAUNDRY www.fantech.net March 2009 – SBL0309
4

VENTILATION SOLUTIONS FOR THE LAUNDRYirvinecodesigncriteria.com/wp-content/uploads/2015/... · 3/16/2015  · VENTILATION FOR THE LAUNDRY ANOTHER FANTECH VENTILATION SOLUTION DRYER

Oct 07, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: VENTILATION SOLUTIONS FOR THE LAUNDRYirvinecodesigncriteria.com/wp-content/uploads/2015/... · 3/16/2015  · VENTILATION FOR THE LAUNDRY ANOTHER FANTECH VENTILATION SOLUTION DRYER

BOOSTER FAN S

A I R F L O W S E N S O R S

A N D L I N T T R A P S

VENT ILAT ION SOLUT IONS FOR THE LAUNDRY

w w w . f a n t e c h . n e t

M a r c h 2 0 0 9 – S B L 0 3 0 9

Page 2: VENTILATION SOLUTIONS FOR THE LAUNDRYirvinecodesigncriteria.com/wp-content/uploads/2015/... · 3/16/2015  · VENTILATION FOR THE LAUNDRY ANOTHER FANTECH VENTILATION SOLUTION DRYER

VENTILATION FOR THE LAUNDRY

ANOTHERFANTECH

VENTILAT IONSOLUTION

DRYER BOOSTER FANS are speciallydesigned to solve the problems caused bylong duct runs on clothes dryers. Long ductruns with multiple elbows can causeextended drying time as well as lint andmoisture build-up within the dryer duct.

WHEN IS A DRYER BOOSTERNECESSARY?According to some dryer installationinstructions and local building codes,booster fans should be added in thedryer duct run when the length of theduct exceeds 25 feet with no bends,20 feet with one bend or 15 feet withtwo bends.

Dryers were designed to be located onan outer wall and directly vented out ofthe building. In today’s home, condo andapartment designs the laundry has beenmoved to interior locations causing theuse of extensive lengths of duct. Mosttypical dryers cannot operate efficientlyagainst the resistance created by thenecessary duct work. In these applicationsa dryer booster fan is the perfect solution.

HOW DO THEY WORK? When the dryer is on, Fantech’s patentedpressure sensing switch automaticallyturns the booster fan on. Thewarm, moist air in the dryerduct is exhausted quickly.

CALCULATING DUCT RUNTo calculate the length of your plannedduct run, measure from the dryer to theexternal venting point in roof or wall.For each bend or elbow add 5-7 feet toyour total duct run calculations. All ofFantech’s Dryer Boosters can be used onruns up to 130 feet except the DBF110which is effective up to 108 feet.

Always consult local codes before installation.

FIVEYEARWARRANTY

Exclusive Wall-MountPanel with LED Lightassures homeownerthat booster fan isworking normally.

Page 3: VENTILATION SOLUTIONS FOR THE LAUNDRYirvinecodesigncriteria.com/wp-content/uploads/2015/... · 3/16/2015  · VENTILATION FOR THE LAUNDRY ANOTHER FANTECH VENTILATION SOLUTION DRYER

DBF4XL Metal Dryer BoosterTap into the power of this dryer booster fan which can be usedon duct runs up to 130 feet. Includes fan with galvanized steelhousing, automatic pressure sensing switch, mounting bracket,hardware and 51/2 foot power cord with plug. Pressure switchactivates fan when dryer comes on. Backward inclined impellerallows lint to pass through the fan.

DRYER BOOSTER FANS/METAL

93/4"33/4"37/8"615/16"

1"

1"2"

2"

3"

2"

37/8"

93/4"

33/4"

37/8"615/16"

1"

1"2"

37/8"

FanModel

MaxWatts

MaxAmps

CFM0" Ps

CFM.2" Ps

DuctDia.

DBF4XL 83 170 150

CFM1.0" Ps

4"

Exhaust Fan Performance

0.73 86

CFM.8" Ps

103

CFM.6" Ps

119

CFM.4" Ps

134

DBF4XLT “Intelligent” Dryer BoosterThe newest dryer booster fan from Fantech is the mostadvanced in the industry. The unit can be used to effectivelyboost dryer exhaust in duct runs up to 130 feet. Fan features galvanized steel housing and integrated airflow sensing switch.Additional components include: mounting bracket, quick-connect/disconnect duct collar, 51/2 foot power cord with plugplus wall-mount indicator panel. LED light on wall panel letshomeowners know fan is working properly.

93/4"33/4"37/8"615/16"

1"

1"2"

2"

3"

2"

37/8"

93/4"

33/4"

37/8"615/16"

1"

1"2"

37/8"

FanModel

MaxWatts

MaxAmps

CFM0" Ps

CFM.2" Ps

DuctDia.

DBF4XLT 83 170 150

CFM1.0" Ps

4"

Exhaust Fan Performance

0.73 86

CFM.8" Ps

103

CFM.6" Ps

119

CFM.4" Ps

134

FIVEYEARWARRANTY

FIVEYEARWARRANTY

NEW“INTELLIGENT”

MODEL

FANTECH’S “INTELLIGENT”DRYER BOOSTER

NOTE: If DBF4XLT is located within 15 linear feet ofthe dryer, a DBLT4 Lint Trap should be added betweenthe dryer and the fan.(See back cover for description.)

Per HVI's Certified Ratings Program, charted airflow performance has been derated by a factorbased on actual test results and the certified rate at .2 inches WG.

Per HVI's Certified Ratings Program, charted airflow performance has been derated by a factorbased on actual test results and the certified rate at .2 inches WG.

Page 4: VENTILATION SOLUTIONS FOR THE LAUNDRYirvinecodesigncriteria.com/wp-content/uploads/2015/... · 3/16/2015  · VENTILATION FOR THE LAUNDRY ANOTHER FANTECH VENTILATION SOLUTION DRYER

INLINE & EXTERIOR-MOUNT DRYER BOOSTERS

United States 10048 Industrial Blvd.Lenexa, KS 66215Phone: 800-747-1762; 913-752-6000Fax: 800-487-9915; 913-752-6466

Fantech, reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position.

Article#412038 SBL0309 ©2009 Fantech, Inc. All Rights Reserved.

DB10 Pressure SwitchAutomatic pressure switch can be used with a Fantech RVF4XLExterior Mount Fan for dryer boost applications. The automaticswitch directs power to the fan in consecutive five minutecycles, effectively providing continuous boost as long as thedryer is on. 115V; 3.8 amps max..

DBLT4 Lint TrapPaintable galvanized metal lint trap for dryer boosting applications. Use when duct length between dryer and booster fan is less than 15 feet. Fits 4-inch duct. Features pull out door with view window, removable lint filter for easy cleaning and 1/2" flange for flush mount installation.

13"

101/4" 6"

37/8"

11/2"

23/4"

FanModel

MaxWatts

MaxAmps

CFM0" Ps

CFM.2" Ps

DuctDia.

RVF4XL 92 193 172

CFM1.0" Ps

4"

Exhaust Fan Performance

0.84 91

CFM.8" Ps

118

CFM.6" Ps

136

CFM.4" Ps

154

13"

101/4" 6"

37/8"

11/2"

23/4"

FanModel

MaxWatts

MaxAmps

CFM0" Ps

CFM.2" Ps

DuctDia.

RVF4XL 92 193 172

CFM1.0" Ps

4"

Exhaust Fan Performance

0.84 91

CFM.8" Ps

118

CFM.6" Ps

136

CFM.4" Ps

154

DB10

DBLT4

FIVEYEARWARRANTY

121/2”

111/4”

91/2”

91/2”

37/8”

37/8”

FanModel

MaxWatts

MaxAmps

CFM0" Ps

CFM.2" Ps

DuctDia.

DBF110 80 167 150

CFM1.0" Ps

4"

Exhaust Fan Performance

0.72 63

CFM.8" Ps

88

CFM.6" Ps

113

CFM.4" Ps

133

FIVEYEARWARRANTY

RVF4XL Exterior-MountExhaust Fan for Dryer BoostingFantech’s popular exterior-mount exhaust fan with white, powder-coated metal housing can be used for dryer boosting whenpaired with a DB10 Pressure Switch (purchase separately). Idealfor condos and apartments as well as homes. Effective on ductruns up to 130 feet. Pressure switch automatically activates thefan when the dryer comes on.

DBF110 Dryer Booster FanThis Fantech Dryer Booster Fan is engineered of thermoplasticresin and features an integrated automatic pressure switch. It canbe used on dryer duct runs up to 108 feet. The fan’s backwardinclined blades allow lint to pass through the fan.

ACCESSORIES

Canada50 Kanalflakt WayBouctouche, NB E4S 3M5Phone: 800-565-3548; 506-743-9500Fax: 877-747-8116; 506-743-9600

Distributed locally by:

Per HVI's Certified Ratings Program, charted airflow performance has been derated by a factorbased on actual test results and the certified rate at .2 inches WG.

Per HVI's Certified Ratings Program, charted airflow performance has been derated by a factorbased on actual test results and the certified rate at .2 inches WG.

[email protected]

jinguyen
Polygon