VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Dec 26, 2015

Download

Documents

Darrell Sanders
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

VENTILASI

TRI MARTIANA

Page 2: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Introduction • A good and effective ventilation system is

necessary in a workplace which have processes that emit air contaminants such as dust, fumes, mists or vapours.

• Substitution or enclosure method• Simple, cheap and effective

Page 3: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Types of Ventilation

Natural General Dilution

LEV

Page 4: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Natural Ventilation• Natural movement of air entering and leaving

openings such as windows, doors, roof ventilators as well as through cracks and crevices of a building

• Heated air rises, cool air below

Page 5: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

General Ventilation• A method of improving or maintaining the

quality of air in the work environment with airflow

• A room or an entire building is flushed by supplying and exhausting large volumes of air throughout the area

1. Supply or forced ventilation

2. Exhaust or induced ventilation

Page 6: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Dilution Ventilation (DV)• DV consists of general ventilation• Uncontaminated outside air + inside air =

diluting and reducing the concentration of air contaminants to acceptable levels to which a worker can be safely exposed for eight hours a day

Page 7: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 8: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 9: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 10: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

LEV• Capture or contain contaminants at their

source before they escape into the work room environment

• System consists of one or more hoods, ducts, air cleaner and a fan

• LEVs remove contaminants rather than just dilute them

Page 11: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Use of Natural Ventilation• Not suitable for processes which emit dust,

fumes, mists or gas• Rooms for chemical storage +• 25% of floor area• Half the ventilating area should be between

floor level and a height of 2.25m from the floor

Page 12: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Use of Dilution Ventilation• DV is usually applied to the control of

contaminants in situation meeting these criteria:

To control vapours (+organic) from low toxicity solvents

To control contaminants released over such a large area or in such a manner that LEV is impossible, impractical or prohibitively expensive

Page 13: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Small quantities of contaminants released into the work room

Rate of contaminant release should be reasonably constant to avoid inadequate dilution during periods of peak contaminant release

No corrosion or other problems from the diluted contaminants in the work room air

Page 14: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Sufficient distance from the worker to the contaminants source to allow dilution to safe levels

Page 15: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• DV is prohibited – control emission of very toxic air contaminants e.g., formaldehyde or other carcinogenic chemicals

• For effective DV, the exhaust outlet and air supply must be so located that all the air employed in the ventilation passes through the zone of contamination

Page 16: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• Avoid re-entrance of the exhausted air.• The advantages and disadvantages of DV are

as follows:

Page 17: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Advantage Disadvantage• Simplicity• Low original cost• Large volumes of dilution air needed• Employee exposures are difficult to control

near source

Page 18: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Use of LEV• The most effective means of controlling air

contaminants is to capture and remove the air contaminants at their source with LEV and to prevent them from being carried away by air currents into the breathing zones of the worker

Page 19: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• Major release (toxic) of localized sources of contaminants.

• LEV consists of 4 parts:

1. Hoods (most important)

2. Ducts

3. Air cleaner device

4. Fan and motor

Page 20: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 21: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 22: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 23: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 24: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 25: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 26: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

High pressureVenturi

Page 27: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• The hood consists of 3 main types to contain and remove the air-borne contaminants.

1. Enclosures

2. Capturing hoods

3. Receiving hoods

Page 28: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Conclusion • Ventilation – an effective way to control toxic

air contaminants if substitution or enclosure method of control is not possible

• DV reduces contaminant concentrations by diluting them with fresh air. (not for toxic emission)

Page 29: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• LEV capture or contain contaminants at their source before they are dispersed in the workroom

• LEVs need to be maintained, inspected and tested regularly to ensure that it is performing adequately

Page 30: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Introduction • A good and effective ventilation system is

necessary in a workplace which have processes that emit air contaminants such as dust, fumes, mists or vapours.

• Substitution or enclosure method• Simple, cheap and effective

Page 31: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Types of Ventilation

Natural General Dilution

LEV

Page 32: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Natural Ventilation• Natural movement of air entering and leaving

openings such as windows, doors, roof ventilators as well as through cracks and crevices of a building

• Heated air rises, cool air below

Page 33: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

General Ventilation• A method of improving or maintaining the

quality of air in the work environment with airflow

• A room or an entire building is flushed by supplying and exhausting large volumes of air throughout the area

1. Supply or forced ventilation

2. Exhaust or induced ventilation

Page 34: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Dilution Ventilation (DV)• DV consists of general ventilation• Uncontaminated outside air + inside air =

diluting and reducing the concentration of air contaminants to acceptable levels to which a worker can be safely exposed for eight hours a day

Page 35: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 36: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 37: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 38: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

LEV• Capture or contain contaminants at their

source before they escape into the work room environment

• System consists of one or more hoods, ducts, air cleaner and a fan

• LEVs remove contaminants rather than just dilute them

Page 39: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Use of Natural Ventilation• Not suitable for processes which emit dust,

fumes, mists or gas• Rooms for chemical storage +• 25% of floor area• Half the ventilating area should be between

floor level and a height of 2.25m from the floor

Page 40: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Use of Dilution Ventilation• DV is usually applied to the control of

contaminants in situation meeting these criteria:

To control vapours (+organic) from low toxicity solvents

To control contaminants released over such a large area or in such a manner that LEV is impossible, impractical or prohibitively expensive

Page 41: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Small quantities of contaminants released into the work room

Rate of contaminant release should be reasonably constant to avoid inadequate dilution during periods of peak contaminant release

No corrosion or other problems from the diluted contaminants in the work room air

Page 42: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Sufficient distance from the worker to the contaminants source to allow dilution to safe levels

Page 43: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• DV is prohibited – control emission of very toxic air contaminants e.g., formaldehyde or other carcinogenic chemicals

• For effective DV, the exhaust outlet and air supply must be so located that all the air employed in the ventilation passes through the zone of contamination

Page 44: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• Avoid re-entrance of the exhausted air.• The advantages and disadvantages of DV are

as follows:

Page 45: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Advantage Disadvantage• Simplicity• Low original cost• Large volumes of dilution air needed• Employee exposures are difficult to control

near source

Page 46: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Use of LEV• The most effective means of controlling air

contaminants is to capture and remove the air contaminants at their source with LEV and to prevent them from being carried away by air currents into the breathing zones of the worker

Page 47: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• Major release (toxic) of localized sources of contaminants.

• LEV consists of 4 parts:

1. Hoods (most important)

2. Ducts

3. Air cleaner device

4. Fan and motor

Page 48: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 49: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 50: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 51: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 52: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 53: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Page 54: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

High pressureVenturi

Page 55: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• The hood consists of 3 main types to contain and remove the air-borne contaminants.

1. Enclosures

2. Capturing hoods

3. Receiving hoods

Page 56: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Conclusion • Ventilation – an effective way to control toxic

air contaminants if substitution or enclosure method of control is not possible

• DV reduces contaminant concentrations by diluting them with fresh air. (not for toxic emission)

Page 57: VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

• LEV capture or contain contaminants at their source before they are dispersed in the workroom

• LEVs need to be maintained, inspected and tested regularly to ensure that it is performing adequately