Global experts in Rotational Moulding Global experts in Rotational Moulding Numerous studies have demonstrated that the peak internal mould air temperature gives a good indication of whether or not a polyethylene rotomoulded part is correctly cured. K-LABEL provides a simple quality control method to check that the moulding has obtained correct cure and avoided under or over curing. • Avoided under curing • Avoid Over Curing Vent Mounted, peak temperature recorded Certified and filed ... job done Label Temperature Control for Rotational Moulding
2
Embed
Vent Mounted, peak temperature recorded Certifi ed and fi led …€¦ · has obtained correct cure and avoided under or over curing. • Avoided under curing • Avoid Over Curing
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Global expertsin Rotational MouldingGlobal expertsin Rotational Moulding
Numerous studies have demonstrated that the peak internal mould air temperature gives a good indication of whether or not a polyethylene rotomoulded part is correctly cured.
K-LABEL provides a simple quality control method to check that the moulding has obtained correct cure and avoided under or over curing.
• Avoided under curing• Avoid Over Curing
Vent Mounted, peak temperature recordedCertifi ed and fi led ... job done
493K Limited, 23 Watch Hill Road, Ballyclare,County Antrim, BT39 9QW, United Kingdom www.493k.comE: [email protected] T: +44 (0)28 9335 9922
Label
K-LABEL mounted using a cable tie
K-LABEL mounted with adhesive tape
K-LABEL Basic displays three separate squares of thermographic ink that which will permanently change colour when they reach a specifi c temperature.
Using K-LABEL Basic for normal roto-grades of polyethylene, correct cure will be indicated when the bottom two squares
have turned from white to black. This indicates that a peak internal mould air temperature of 204° has been reached. If no squares, or only one square, of ink has changed colour, the part will probably be under-cured. If all three squares have changed colour, the part will probably be over-cured.
K-LABEL Advanced comes with eight squares of thermographic ink. The advanced label provides a much wider range of measurement allowing for more precise control. It will also accommodate cure of other polymer grades.