SPECIFIERS GUIDE Vector F40
Apr 04, 2016
SPECIFIERS GUIDE
Vector F40
2
Key Features ≤ 588lm/m 179lm/ft
≤ 9.36w/m 2.85w/ft
≤ 63lm/w
≤ 88 CRI
≤ 6m (19.5ft)
2600 / 2900 / 3300K CCT
PowerTHRU
12VDC CV
IP67
Overview
Vector F40
Cost effective IP67 lighting solution for linear or curved, wet or dry concealed lighting applications such as coving, backlighting, signage panels or illuminated stretch ceilings. Dimmable White Spectrum™ twin LED modules are spaced with exactly 40mm between each LED to provide a consistent line of light.
F40 can be specified ‘per metre’ in lengths of up to 6m (19.5ft) in series or longer lengths wired in parallel at 12VDC. Fixing via self-adhesive 3M mounting pads or mounting clips. Note: F40 is not suitable for exterior use when mounted in direct sunlight.
3
Applications
Images clockwise from top:
1. Oval concealed cove Corinthia Hotel London 2. Bar backlighting Ormer Restaurant Jersey 3. Concealed stairs Cultural Centre Baku 4. Bar underlighting Annabel’s Club London
F40 is ideally suited to concealed lighting applications such as coving, backlighting for stretched ceilings.
4
Performance
Performance Table 9.36W /m
CCT lumens /m lumens /w watts /m CRI R9
2600K 479 51 9.36 88 +56
2900K 588 63 9.36 60 -49
3300K 561 60 9.36 81 +30
Power rated at 12vdc. Data @25°C Ta
LED
3-Chip 5450 SMT package40.0mm mounting pitch
Light output ratio
1.00 LOR 115º beam angle
5
F40 module lumen output testing and photometric data conducted by independent UKAS accredited test laboratory, LUX-TSI. Test duration approx 20 minutes at ambient temperature of 24.4C with 24hr burn-in time. Stabilisation period, approx. 60 minutes. Humidity <65% RH.
0° 30°30°
60°
90°
120°
0° 30°30°
60°
90°
120°
C90°C0°
Polar DistributionCIE 1931 X & Y Chromaticity
y
4.15
4.05
4.10
4.70 4.804.75x
2600K
2 SDCM
dv
dh
1.0
2.0
3.0
5.0
4.0
6.0
m
216
54
24
9
14
6
lx
3.2
6.3
9.5
15.8
12.6
19.0
dv
3.1
6.2
9.3
15.4
12.3
18.5
dh
Illuminance at a distanceLumen maintenence @25°C Ta
10,000 50,00030,000hrs
120
100
80
60
40
20
lm%
L70
49,500hrs
Photometric Data
150cd
250cd
6
Dimensions
~130g per metre
40.0
0
10.00
12.00
22.0
058
.00
40.0
0
9.50
7
IDC Dimensions
Accessories
6.8
0
97. 9
15.3
2.65
2.65
OPEN - 8.75
CLOSED - 6.5
Water Resistant Connectors
VECA-CA901-R1 Twin pack IDC Sealant Connector
Discreet IDC connectors are used to join two wires together while maintaining a water resistant seal. The principle used is the insulation displacement technique while the silicon sealant used in the connector provides effective wa-ter & moisture protection, no wire stripping is required. Robust hand pliers can be used to crimp the connectors, however we recommend the use of Scotchlok™ Hand Crimping Tool E-9Y.
8
Drivers & Dimming
Dimming with 1-10V / DALI / DMX
F40 is ideally suited to dimming with 1-10V control signal using the Vector P12-100/180-D10 dim-mable driver. Alternatively a non-dimmable driver can be combined with a PWM interface suitable for 1-10V, DALI or DMX control.
12VDC
Wiring
F40 can be installed in power-through configuration lengths up to 6 metres subject to maximum ca-ble size and length. Longer lengths can easily be achieved by running parallel feeds as shown in the 10m (2 x 5m) example below.
12VDC
6m example
12VDC Driver Interface
max. 2m
Dim Signal
230VAC
VECTOR DIMMABLE DRIVER
230VAC
Dim Signal
10m (2x5m) example
9
Installation Notes
12VDC power supplies and dimming interfaces are often tested and verified to be EMI compliant with secondary cable lengths of up to 10m (shorter lengths on some devices). For cable lengths exceeding 10m, EMI emissions should be verified in the application. When EMI emissions exceed the allowed levels it may be possible to reduce them by using ferrite cores (not supplied).
12VDC cables should be shielded if longer than 10m total length. Recommended maximum cable lengths for dimmed circuits should be adjusted to allow a typical dimming interface voltage drop of 0.3V. Installers should check the specific voltage drop of the interface they are using and adjust cable length accordingly. A reduction of 10% in total cable length is normally sufficient.
*Recommended cable lengths shown are based on average resistance for typical copper solid core cables. Cable characteristics may vary acording to manufacturer, temperature, copper purity, connections etc. Installers must make their own checks to avoid voltage drop issues.
Drivers & Cabling
Drivers must be of constant voltage type providing 12VDC power supply. Recommended mini-mum driver wattage ratings are shown in the table below along with maximum recommended cable lengths. The performance of different cable types may vary and installers should check that at least 9.6V is maintained at the end of the F40 run.
It is recommended that only drivers with overload and short-circuit protection are used. Cable lengths should be reduced by 10% if dimming.
>1m>2m>3m>4m>5m>6m
0.781.562.343.123.904.68
F40 A
F40Length
9.3618.7228.0837.4446.8056.14
F40W
73m37m24m18m15m12m
117m59m39m29m23m20m
188m94m63m47m38m31m
300m150m100m75m60m50m
480m240m160m120m96m80m
0.5mm²20AWG
0.75mm²18AWG
1.0mm²17AWG
1.5mm²15AWG
2.5mm²13AWG
10
Wiring Examples
Switched
100W 12VDC DRIVER
Dim Signal
230VAC
100W P12-100-D10DIMMABLE DRIVER
230VAC
Dim Signal
Dimmed
230VAC
100W 12VDC DRIVER
12m max. [0.5mm² / 20AWG] 6m max.
6m max.
6m max.
Interface
10.8m max. [0.5mm² / 20AWG]
10.8m max. [0.5mm² / 20AWG]
11
Optional Double Fixing Mount
Optional Fixing Mount
Mounting Examples
Application Guide
150
50
170
F40S-MA520-R1 F40 Mount (x20) F40S-MA500-R1 F40 Mount (x100) F40S-MA800-R1 F40 Mount (x500) 11.50
13.7
5
Self-adhesive tape backing supplied as standard. Mounts are optional for additional security. Recommended quantity 6 per metre.
24
14.2
5
F40S-MA530-R1 F40 Twin Mount (x20) F40S-MA510-R1 F40 Twin Mount (x100) F40S-MA810-R1 F40 Twin Mount (x500)
Self-adhesive tape backing supplied as standard. Mounts are optional for additional security. Recommended quantity 6 per metre.
12
White Spectrum™ LED
Vector LEDs with White Spectrum™ technology benefit from ultra-fine LED x,y binning coordinates to precise specifications. Testing and control of these specifications gives very accurate control of correlated colour temperatures (CCT). White Spectrum™ technology also allows us to offer our high colour rendering index rating of 88 CRI (Ra) as standard for 2600K products.
Each 2600K Vector LED is ultra-fine binned from a defined x, y range bin area covering approximately 2 MacAdam steps. This is far smaller than the ANSI C78.377A Standard which equates to 7 Mac-Adam steps. This binning accuracy equates to a colour temperature precision of less than 2.0% tolerance giving approximately +/- 50K.
White Spectrum™ is one of the leading global LED technologies. A typical warm white fine-bin from another manufacturer is typically at least 40% larger than Lumino’s White Spectrum™ ultra-fine bin-ning.
0.39
0.43
0.41
0.41 0.490.470.450.43
2800K
VECTOR 2600K2-step MacAdam
ANSI C78.377A 2700K7-step MacAdam
2600K
LED Specification
13
Specification Codes
F 4 0 I E A-S 6 0 0 0 C- 1 AP A
LED CCT
CDF
2600K WS2900K WS3300K WS
Codes
14
Technology
Certification Standards
EN55015: 2006+A1 :2007
EN61547: 1995+A1 :2000
Following the provisions of EMC Directive 2004/108/EC
Material specifications
Injection moulded polycarbonate module housings PCB electroplated copper foil on FR4 substrate 20AWG wires stranded copper / PVC
Operating environment
Running Temperature (Tc): Ave. 17°C above Ta Ambient Temperature (Ta): -20 to +60°C Storage Temperature: -30 to +80°C Ingress Protection rating: IP67 IP67
15
The information in this document is subject to change without notice
Check for latest specifications at www.lumino.co.uk
Copyright © 2014 Lumino Limited
E&OE
Lumino Limited Lumino House, Lovet Road Harlow, Essex CM19 5TB United Kingdom
T +44 (0) 1279 635411 E [email protected]
www.lumino.co.uk
Vector F40
SG-F40S-R1407