Page 1: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Integrated Vapor Intrusion Mitigation and Soil Vapor

Extraction Implementation for a Complex Building

Foundation

Authors: Omer J. Uppal, Matthew Ambrusch, Steven Ciambruschini,

Nadira Najib, Stewart H. Abrams, and Matthew Wenrick

Page 2: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Presentation Outline

Vapor Intrusion

How to Mitigate

What is SSDS?

SSDS Versus SVE

Components of a SSDS Design

SSDS Design Challenges

Case Study – Manhattan, New York

Lessons To Be Learned

Page 3: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Vapor Intrusion Migration of volatile chemicals from contaminated groundwater or

soil into buildings above

Indoor Air Quality

Chronic and acute health/safety hazards

Page 4: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

How to Mitigate

Passive Venting Systems

Impermeable Membrane Liners

Sub-Slab Depressurization Systems

http://www.nj.gov/dep/srp/guidance/vaporintrusion/subsurface.htm

Page 5: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

What is a SSDS?

Active venting system consisting of:

Fan/Blower

Well Network

Vacuum/Air Flow Rate Instrumentation

Control Panel

Telemetry System

Emission Controls

Page 6: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

SSDS Versus SVE

Differences: Purpose

MITIGATION versus REMEDIATION

Capture versus Extraction

Similarities: Principals

Active Pneumatic Systems

Dependent on intrinsic permeability

Page 7: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Design Components of a SSDS Design

• Pilot Testing

• Modeling

• Design Criteria

• Air Flow Rate

• Vacuum

• ROI

Page 8: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

SSDS Design Challenges

• Existing Structures

• Slab on grade

• Space/Access Constraints

• Heterogeneous Geology

• High Water Table

Page 9: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Case Study – Manhattan, New York

Page 10: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Site Background

Operated until June 2013 as an active dry cleaning facility

Residential dwellings located on floors two through five.

Indoor air assessment - PCE and TCE in exceedance of NYSDOH

Vapor Intrusion Guidance Matrix.

Page 11: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Site Constraints

2 - 6 inch thick concrete slab with granite bedrock beneath

Limited space for implementation/Manual drilling required

Possible demolition of building during application period

Page 12: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Pilot Testing

5 Vapor Recovery Wells (VP)

3 Shallow Vapor Probes (SVP)

Understand the site-specific sub-surface parameters (i.e., permeability)

to design the full-scale SSDS.

Page 13: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Outputs:

Ki, ROI, FD , PV exchanges

Benefits:

More cost-effective design

Valuable tool for SVE and VI Mitigation systems

Helps to ensure efficient and effective vapor mitigation

Modeling

MDFIT – Computer Pneumatic Modeling Program

Page 14: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Full-Scale Results

SSDS was meeting the required minimum sub-slab vacuum of

0.004 inches of water column (as recommended by USEPA)

Mitigating AND Remediating

Page 15: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Lessons To Be Learned

SSDS can be performed efficiently, even at complex sites, if we

understand and consider the constraints of the site when designing

the system.

Importance of pilot testing and pneumatic modeling when

designing/installing a SSDS in an existing building.

Properly designed systems can provide effective mitigation even in

a complex lithology (i.e., bedrock).

Page 16: Vapor Intrusion Mitigation Battelle 2014 - UPPAL 1

Questions?