 G-78 Internet Contact Details Before using the product, please check the guide pages at the front of this catalog. http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Seat Type Solenoid Valve JIS graphic symbols for hydraulic system Features  No hydraulic locking occurs even during long periods of pressurized operation Nomenclature  - JSC -    01 - 2    - 10 -   1 2 3 4 5 6 7 8 Applicable fluid code  No designation: Petroleum-base d hydraulic uid F: Phosphate ester hydraulic uid Model No. JSC: J series seat type solenoid valve Connections G: Gasket mount type C: Cartr idge mo unt type Nominal diameter 01: Maximum operating pressure 2: 25 MPa { 250 kgf/cm 2 } Voltage code (See the solenoid specification table) Design No. (The design No. is subject to change) Option code  No designation: Lead wir e type C: DIN connecto r type (without lamp) CL: DIN connector type (with lamp) Specifications Model No. Nominal diameter Maximum operating pressure MPa {kgf/cm 2 } Maximum flow rate L/min Maximum switching frequency Times per minute Leak amount cm 3 /min Mass kg Gasket mount type (G) Cartridge mount type (C) JSC-01  25 {250} 15 240 0.25 maximum 0.97 0.27 6 : Solenoid specification table Voltage code Power supply voltage Starting current  A Holding current  A Holding power W Permissible voltage fluctuation %  A  AC 100 V (50 Hz) 0.362 0.258 17 80 to 110  AC 100 V (60 Hz) 0.318 0.208 14 90 to 121  AC 1 10 V (60 Hz) 0.356 0.244 18 82 to 11 0 B  AC 200 V (50 Hz) 0.1 83 0.1 3 17 80 to 11 0  AC 200 V (60 Hz) 0.1 58 0. 104 14 90 to 121  AC 220 V (60 Hz) 0.1 78 0. 121 18 82 to 11 0 N DC 12 V  1.48 17 .8 90 to 1 10 P DC 24 V  0.74 17.8 90 to 110 Note: The current and power indicated are the values at 20 °C. Time rating Insulation resistance Withstand voltage Insulation type Continuous 50 M AC 1500 V, 1 minute Class B (Class H for coi ls) Accessories (gasket mount type) Hexagon sock et head cap bolt Quantity Tightening torque N·m {kgf·cm} M5 × 45 4 6 to 8 {60 to 80} B  A 1 2 4 5 6 7 8 3
3

valve sheet.pdf

Oct 08, 2015

Download

Documents

Timothy Fields

data sheet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • G-78

    InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

    http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

    Seat Type Solenoid ValveJIS graphic symbols for hydraulic system

    Features No hydraulic locking occurs even during long periods of pressurized

    operation

    Nomenclature - JSC - 01 - 2 - 10 - 1 2 3 4 5 6 7 8

    Applicable fluid codeNo designation: Petroleum-based hydraulic fl uidF: Phosphate ester hydraulic fl uid

    Model No.JSC: J series seat type solenoid valve

    ConnectionsG: Gasket mount typeC: Cartridge mount type

    Nominal diameter01:

    Maximum operating pressure2: 25 MPa {250 kgf/cm2}

    Voltage code (See the solenoid specification table)

    Design No. (The design No. is subject to change)

    Option codeNo designation: Lead wire typeC: DIN connector type (without lamp)CL: DIN connector type (with lamp)

    Specifications

    Model No. Nominal diameter

    Maximum operating pressure

    MPa {kgf/cm2}

    Maximum flow rate

    L/min

    Maximum switching frequency

    Times per minute

    Leak amountcm3/min

    Mass kg

    Gasket mount type (G) Cartridge mount type (C)

    JSC-01 25 {250} 15 240 0.25 maximum 0.97 0.27

    6 : Solenoid specification table

    Voltage code Power supply voltage

    Starting currentA

    Holding currentA

    Holding powerW

    Permissible voltage fluctuation %

    A

    AC 100 V (50 Hz) 0.362 0.258 17 80 to 110

    AC 100 V (60 Hz) 0.318 0.208 14 90 to 121

    AC 110 V (60 Hz) 0.356 0.244 18 82 to 110

    B

    AC 200 V (50 Hz) 0.183 0.13 17 80 to 110

    AC 200 V (60 Hz) 0.158 0.104 14 90 to 121

    AC 220 V (60 Hz) 0.178 0.121 18 82 to 110

    N DC 12 V 1.48 17.8 90 to 110

    P DC 24 V 0.74 17.8 90 to 110Note: The current and power indicated are the values at 20C.

    Time rating Insulation resistance Withstand voltage Insulation type

    Continuous 50 M AC 1500 V, 1 minute Class B (Class H for coils)

    Accessories (gasket mount type)

    Hexagon socket head cap bolt Quantity Tightening torque Nm {kgfcm}

    M5 45 4 6 to 8 {60 to 80}

    B

    A

    1

    2

    4

    5

    6

    7

    8

    3

  • GDIR

    EC

    TIO

    NA

    L C

    ON

    TRO

    L VA

    LVE

    S

    G-79

    InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

    http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

    Performance curves (viscosity: 32 mm2/s {cSt}) Operation time (Sec.)Pressure drop characteristics Power

    supplyOperating direction

    Operation time Sec.

    ACExcited 0.02 to 0.03

    Demagnetized 0.02

    DCExcited 0.03

    Demagnetized 0.03 to 0.04

    Note: The operation time may change slightly depending on the conditions of use (pressure, flow rate, hydraulic fluid viscosity, etc.).

    Handling Wiring guide for solenoid (AC solenoid valve)

    Solenoids can be used with both 50 and 60 Hz. Flow directionFlow A B is blocked with the solenoid at the normal position (non-energized state), and fl ow B A becomes a free fl ow at the cracking pressure of approximately 0.2 MPa {2 kgf/cm2}.

    Flow B A cannot be utilized with the solenoid excited. Tightening torque

    Tightening torque Nm {kgfcm}

    Cartridge 66 to 70 {660 to 700}

    Button bolt 3 to 4 {30 to 40}

    Solenoid model codes

    Details Model code of solenoid coil

    Lead wire type C-PS-DIN connector type C-PS--C1

    Note: : Voltage code DIN connector type solenoid coils are not provided with a DIN connector socket.When a DIN connector socket is required, order it from your nearest distributor, specifying the model code given in the table below.Manufacturer: Hirschmann

    Model code Power supply voltage Details

    GDM2011 Without lamp

    GDML2011-LG110-H0 AC 100 V, AC 110 V

    With lampGDML2011-LG240-H0 AC 200 V, AC 220 V

    GDML2011-2LED12-H0 DC 12 V

    GDML2011-2LED24-H0 DC 24 V

    1.5

    1.0

    0.5

    00 5 10 15

    Pre

    ssur

    e dr

    op(M

    Pa)

    {10

    kgf

    /cm

    2 }

    Flow rate (L/min)

    Inlet port Outlet port(A B)

    Showing the valuesmeasured with a gasket type sub-block fitted

    ( )

    Outlet port Inlet port(B A)

  • 1 2 3 4 5

    8477

    .5

    46

    23

    46

    2001

    0Button bolt: M54-9.5Counter bore

    43 37.5

    5.3 712

    112

    7.45

    31.7

    531

    15.5

    0.75

    25.9 5.1

    AB

    12.7

    21.5

    30.240.5

    61

    12.25

    3.2a

    3.2a 1.6a

    M22 1.5, depth 22

    0.05

    30

    6 drill

    P

    P

    60

    45

    15

    +0.0

    30

    19

    +0.40

    23.

    8 0

    .1

    2544 to 46

    10.1

    0.05

    P

    T

    29 (Drill hole depth)

    1.6a

    2.6

    Lead wire 0.75 mm2

    1020

    0

    23(1

    9.5)

    37

    18.

    9 0.

    050

    26.

    5 0.

    2

    Port A side

    Port B side

    M22 1.5

    Filter 1940

    (92)52

    46

    (42.

    5)

    1

    27 (Width across flats)

    G-80

    InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.

    http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals

    External dimension diagram

    JSC-C01-2-10 (AC, DC) Mount dimensions

    JSC-G01-2-10 (AC, DC) JSC-C01-2-10-C (L) (Option)

    JSC-G01-2-10-C (L) (Option)

    The direction of the coil can be changed as required by loosening the button bolt.

    Sectional structural diagram JSC-C01

    Space required to remove the coil

    Sealing part tablePart No. Name Part specifications Quantity

    1 Backup ring JIS B 2407 bias cut P15 1

    2 O-ring JIS B 2401 1BP15 1

    3 O-ring AS568-116 NBR, Hs90 1

    4 O-ring JIS B 2401 1BP12 1

    5 O-ring JIS B 2401 1BP11.2 1