V68H - Olympian Plus plug-in system Pressure relief valves 05/16 en 8.260.500.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2000 - 8095d) © 2015 IMI International s.r.o. Medium: Compressed air only Maximum operating pressure: 20 bar (290 psi) Outlet pressure adjustment range: Standard 0,3 ... 10 bar (4 ... 145 psi) Optional 0,3 ... 4 bar ( 4 ... 58 psi), 0,7 ... 17 bar (10 ... 246 psi) Port sizes: 3/4”, 1”, 1 1/4” or 1 1/2” Gauge port: 1/8 PTF with PTF main ports Rc1/8 with ISO G main ports- Gauge ports: Rc 1/8 Relief port: 1” PTF with PTF yoke ports G1 with ISO G yoke ports Ambient/Media temperature: -20° ... +80°C (-4° ... +176°F) Version with gauge: -20° ... +65°C (-4° ... +149°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Body, bonnet & yoke: aluminium Adjusting screw: steel Elastomers: NBR Technical features > Port size: 3/4“ ... 1 1/2“ (ISO G/PTF) > Olympian relief valves protect compressed air systems from over-pressurisation > High relief capacity, sensitive and accurate > Threaded relief port for silencer or piped exhaust Technical data - standard models Symbol Port size Size Pressure range (bar) Weight (kg) Model G3/4 0,3 ... 10 2,21 V68H-6GD-RMN G1 Basic 0,3 ... 10 2,20 V68H-8GD-RMN G1 1/4 0,3 ... 10 2,22 V68H-AGD-RMN G1 1/2 0,3 ... 10 2,26 V68H-BGD-RMN Without yoke 0,3 ... 10 V68H-NND-RMN V68H-˙˙D-R˙˙ Option selector Port size Substitute 3/4“ 6 1” 8 1 1/4” A 1 1/2” B Without yoke (standard) N Thread Substitute PTF A ISO G parallel (standard) G Gauge Substitute With G Without (standard) N Spring (Outlet Pressure Range) *1) Substitute 0,3 ...10 (standard) M 0,3 ... 4 F 0,7 ... 17 S *1) Relief valves can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.
4

V68H - Olympian Plus plug-in system Pressure relief valvescdn.norgren.com/pdf/en_8_260_500_V68H.pdf · V68H - Olympian Plus plug-in system Pressure relief valves Our policy is one

Feb 06, 2018

Download

Documents

PhạmTuyền
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: V68H - Olympian Plus plug-in system Pressure relief valvescdn.norgren.com/pdf/en_8_260_500_V68H.pdf · V68H - Olympian Plus plug-in system Pressure relief valves Our policy is one

V68H - Olympian Plus plug-in system Pressure relief valves

05/16en 8.260.500.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2000 - 8095d) © 2015 IMI International s.r.o.

Medium:Compressed air only Maximum operating pressure:20 bar (290 psi)Outlet pressure adjustment range:Standard 0,3 ... 10 bar (4 ... 145 psi) Optional 0,3 ... 4 bar ( 4 ... 58 psi), 0,7 ... 17 bar (10 ... 246 psi)

Port sizes:3/4”, 1”, 1 1/4” or 1 1/2”Gauge port:1/8 PTF with PTF main portsRc1/8 with ISO G main ports-Gauge ports:Rc 1/8 Relief port:1” PTF with PTF yoke portsG1 with ISO G yoke ports

Ambient/Media temperature:-20° ... +80°C (-4° ... +176°F) Version with gauge: -20° ... +65°C (-4° ... +149°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials:Body, bonnet & yoke: aluminium Adjusting screw: steel Elastomers: NBR

Technical features

> Port size: 3/4“ ... 1 1/2“ (ISO G/PTF)

> Olympian relief valves protect compressed air systems from over-pressurisation

> High relief capacity, sensitive and accurate

> Threaded relief port for silencer or piped exhaust

Technical data - standard modelsSymbol Port size Size Pressure

range(bar)

Weight

(kg)

Model

G3/4 — 0,3 ... 10 2,21 V68H-6GD-RMN

G1 Basic 0,3 ... 10 2,20 V68H-8GD-RMN

G1 1/4 — 0,3 ... 10 2,22 V68H-AGD-RMN

G1 1/2 — 0,3 ... 10 2,26 V68H-BGD-RMN

Without yoke — 0,3 ... 10 V68H-NND-RMN

V68H-˙˙D-R˙˙Option selectorPort size Substitute

3/4“ 6

1” 8

1 1/4” A

1 1/2” B

Without yoke (standard) N

Thread Substitute

PTF A

ISO G parallel (standard) G

Gauge Substitute

With G

Without (standard) N

Spring (Outlet Pressure Range) *1)

Substitute

0,3 ...10 (standard) M

0,3 ... 4 F

0,7 ... 17 S

*1) Relief valves can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.

Page 2: V68H - Olympian Plus plug-in system Pressure relief valvescdn.norgren.com/pdf/en_8_260_500_V68H.pdf · V68H - Olympian Plus plug-in system Pressure relief valves Our policy is one

V68H - Olympian Plus plug-in system Pressure relief valves

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2000 - 8095d) © 2015 IMI International s.r.o.en 8.260.500.02

05/16

Inlet pressure 10 bar

Air flow

Ou

tlet

pre

ssu

re

How to select a relief valveThe function of a relief valve is to help prevent an over pressure condition that could result in damage to downstream equipment. Typically, a pressure regulator reduces the supply pressure from the air compressorto a suitable working pressure. The relief valve is installed downstream of the regulator to protect downstream equipment from high pressure spikes.Flow capacity of the relief valve selected must equal or exceed the flow and pressure rating of the air compressor.

EXAMPLE:If your compressor delivers 47 dm3/s (100 scfm) at 12 bar (175 psi) and your system requires a working pressure of 6.2 bar (90 psi), the relief valve must have a set pressure slightly higher than the 6,2 bar (90 psi) working pressure and be capable of flowing 47 dm3/s (100 scfm) at 12 bar (175 psi), or pressures less than 12 bar (175 psi).

0 50 100 150 200 250 dm3/s

0 100 200 300 400 500 600 scfm

12

10

8

6

4

2

0

bar

160

120

80

40

0

psi

See example

Flow characteristics

Unported Pressure range 1 ... 10 bar (15 ... 145 psi)

Service kitService kit

V68H-KIT

Thread

Single yoke Double yoke End connector kit

Single yoke non threads

3/2 Shut-off valveThreaded inlet only Threaded outlet only

Bracket mounting

G3/4 Y68A-6GN-N1N Y68A-6GN-N2N 5524-55 74785-98 T68H-6GB-B2N T68H-6GC-B2N 18-001-979

G1 Y68A-8GN-N1N Y68A-8GN-N2N 5524-52 T68H-8GB-B2N T68H-8GC-B2N 18-001-979

G1 1/4 Y68A-AGN-N1N Y68A-AGN-N2N 5523-52 T68H-AGB-B2N T68H-AGC-B2N 18-001-978

G1 1/2 Y68A-BGN-N1N Y68A-BGN-N2N 5523-93 T68H-BGB-B2N T68H-BGC-B2N 18-001-972

3/4 PTF Y68A-6AN-N1N Y68A-6AN-N2N 5524-53 T68H-6AB-B2N T68H-6AC-B2N 18-001-979

1 PTF Y68A-8AN-N1N Y68A-8AN-N2N 5524-50 T68H-8AB-B2N T68H-8AC-B2N 18-001-979

1 1/4 PTF Y68A-AAN-N1N Y68A-AAN-N2N 5523-50 T68H-AAB-B2N T68H-AAC-B2N 18-001-978

1 1/2 PTF Y68A-BAN-N1N Y68A-BAN-N2N 5523-95 T68H-BAB-B2N T68H-BAC-B2N 18-001-972

Nut Tamper resistant cover

Porting block Silencer

5520-89 1581-90 18-026-986 (G1/4 & G1/2) MB008B (R1)

18-026-983 (1/4 & 1/2 NPT) MB008A (1 NPT)

Accessories

GaugesCenter back connection, white face (full technical specification see datasheet 8.900.900)

Pressure range bar *1 MPa psi Ø Thread size Model

0 ... 4 0 ... 0,4 0 ... 58 50 mm R1/8 18-013-011

0 ... 10 0 ... 1 0 ... 145 50 mm R1/8 18-013-013

0 ... 25 0 ... 2,5 0 ... 362 50 mm R1/8 18-013-014

*1) primary scale

Center back connection, black face for North America (full technical specification see datasheet 8.900.900)

Pressure range psig *1 bar MPa Ø Thread size Model

0 ... 60 0 ... 4 0 ... 0.4 2” (50 mm) 1/8 NPT 18-013-202

0 ... 160 0 ... 11 0 ... 1.1 2” (50 mm) 1/8 NPT 18-013-204

0 ... 400 0 ... 28 0 ... 2.8 2” (50 mm) 1/8 NPT 18-013-206

*1) primary scale

Page 3: V68H - Olympian Plus plug-in system Pressure relief valvescdn.norgren.com/pdf/en_8_260_500_V68H.pdf · V68H - Olympian Plus plug-in system Pressure relief valves Our policy is one

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2000 - 8095d) © 2015 IMI International s.r.o.

V68H - Olympian Plus plug-in system Pressure relief valves

en 8.260.500.0305/16

Service kitService kit

V68H-KIT

Basic dimensions Dimensions in mm Projection/First angle

256 23

2

54

190 3

11 8

5 or 3/16”7

62

# Minimum clearance required to remove unit from yoke 1 Main ports 3/4”, 1”, 1 1/4” or 1 1/2” 3 Plus 10 mm for ports 1 1/4” or 1 1/2”7 Gauge port 1/8” 8 Relief port 1”

208

190

15

125

100

72

125,

5

2,5

190

4

8,5

1

1

1

333

315

12595

15

125

100

72 2,5

315

4

9

8,5

125,

5

1

1

1

1 For 1 1/4” and 1 1/2” ported yokes add 10 mm 1 For 1 1/4” and 1 1/2” ported yokes add 10 mm

Single yoke with bracket Double yoke with bracket

Page 4: V68H - Olympian Plus plug-in system Pressure relief valvescdn.norgren.com/pdf/en_8_260_500_V68H.pdf · V68H - Olympian Plus plug-in system Pressure relief valves Our policy is one

V68H - Olympian Plus plug-in system Pressure relief valves

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2000 - 8095d) © 2015 IMI International s.r.o.en 8.260.500.04

05/16

WarningThese products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, IMI International s.r.o.Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with these products.

Diese Produkte sind ausschließlich in Druckluftsystemen zu verwenden. Sie sind dort einzusetzen, wo die unter »Technische Merkmale/-Daten« aufgeführten Werte nicht überschritten werden. Berücksichtigen Sie bitte die entsprechende Katalogseite. Vor dem Einsatz der Produkte bei nicht industriellen Anwendungen, in lebenser-haltenden- oder anderen Systemen, die nicht in den veröffentlichten Anleitungsunterlagen enthalten sind, wenden Sie sich bitte direkt an IMI Precision Engineering, IMI International s.r.o.Durch Missbrauch, Verschleiß oder Störungen können in Pneumatik-

systemen verwendete Komponenten auf verschiedene Arten versagen.Systemauslegern wird dringend empfohlen, die Störungsarten aller in Pneumatiksystemen verwendeten Komponententeile zu berück-sichtigen und ausreichende Sicherheitsvorkehrungen zu treffen, um Verletzungen von Personen sowie Beschädigungen der Geräte im Falle einer solchen Störung zu verhindern. Systemausleger sind verpflichtet, Sicherheitshinweise für den End-benutzer im Betriebshandbuch zu vermerken, wenn der Störungs-schutz nicht ausreichend gewährleistet ist.

Te produkty są przeznaczone do pracy wyłącznie w przemysłowych układach ze sprężonym powietrzem i płynami. Nie używać produktów tam, gdzie ciśnienia i temperatury mogą przekroczyć parametry podane w sekcji „Cechy/Dane techniczne”. Przed użyciem produktów z płynami innymi niż określono i w celach innych niż przemysłowe, w systemach podtrzymywania życia i w innych zastosowaniach niewymienionych w opublikowanych specyfikacjach należy skontaktować się z IMI Precision Engineering, IMI International s.r.o.W wyniku niewłaściwego użytkowania lub procesów zużycia oraz usterek,

zastosowane komponenty w pneumatycznych i hydraulicznych układach zasilających mogą ulec awarii.Przestrzega się konstruktorów do zastosowania wszelkich środków bezpieczeństwa w celu uniknięcia obrażeń osobistych i zniszczenia mienia na wypadek awarii komponentów zastosowanych w układzie zasilania.Przestrzega się konstruktorów układów, aby zapoznać się ze szczególnymi ostrzeżeniami zamieszczonymi na kartach danych z instrukcjami, które są pakowane i wysyłane razem z produktami.

Les produits de ce catalogue ne conviennent que pour les systèmesindustriels fonctionnant à l‘air comprimé. Ne jamais soumettre cesappareils à des pressions ou à des températures autres que cellesindiquées dans les caractéristiques techniques.Pour une utilisation avec un fluide non spécifié dans cette fichetechnique, les applications non industrielles, les appareils derespiration artificielle ou toute autre application ne correspondant pasà nos spécifications, consultez notre service technique IMI Precision Engineering, IMI International s.r.o.Une utilisation abusive, l’âge des appareils ou leur manque d’entretienpeuvent entraîner différents types de dysfonctionnements.

Il est conseillé aux concepteurs de machines d’étudier tous les modesde défaillance de chacun des composants et de prévoir les protectionsnécessaires de manière à éviter tout accident corporel ou toutdommage aux systèmes environnants en cas de défaillance de l’un deceux-ci.Lorsqu‘une protection appropriée ne peut être installée, le concepteurde machine devra informer les utilisateurs des risques encourus parune mention portée dans sa notice d’utilisation.Il est recommandé aux concepteurs de systèmes et aux utilisateurs deprendre connaissance des mises en garde portées sur les feuilletsfournis avec les appareils ou bien indiquées directement sur ces derniers.

Estos productos están destinados a que se utilicen únicamente ensistemas industriales de aire comprimido. No utilizar estos productoscuando la presión y temperatura puedan exceder las especificadasen los ‘Datos Técnicos ’.Antes de utilizar estos productos con fluidos que no sean losespecificados, para aplicaciones no industriales, sistemas médicosanitarios u otras aplicaciones que no se encuentren entre las especificaciones publicadas, consultar IMI Precision Engineering, IMI International s.r.o.Por mal uso, antigüedad o montaje deficiente, los componentesutilizados en sistemas de fluidos energéticos pueden fallar y provocardiversos tipos de accidentes.

Se advierte a los diseñadores de sistemas que deben considerar laposibilidad de mal funcionamiento de todos los componentes utilizadosen sistemas de fluidos y prever las medidas adecuadas de seguridadpara evitar daños personales o desperfectos en el equipo en elsupuesto de producirse tales fallos.En el caso de no poder proporcionar la protección adecuada frente aalgún fallo, los diseñadores del sistema deben advertirlo al usuario finalen el manual de instrucciones.Se aconseja a los diseñadores del sistema, así como a los usuariosfinales, que revisen las advertencias especificadas de montaje que seindican en las hojas técnicas.

Questi prodotti sono adatti solo per l’impiego in impianti industrialifunzionanti con aria compressa. Non devono essere utilizzati nei casiin cui le condizioni di pressione e di temperatura non rientrino nei valoriindicati nelle ‘Caratteristiche Tecniche’.Prima di utilizzare questi prodotti con fluidi differenti da quelli indicati,per applicazioni non industriali, sistemi medico-sanitari o altreapplicazioni non specificatamente indicate nella documentazione,consultare la IMI Precision Engineering, IMI International s.r.o.In seguito all’utilizzo errato, l’invecchiamento o al mal funzionamento,

i componenti utilizzati in impianti pneumatici possono danneggiarsi. I progettisti degli impianti devono prendere in considerazione tutte lepossibilità di rottura dei componenti utilizzati nell’impianto pneumatico eprevedere dispositivi di sicurezza per evitare lesioni all’operatore odanneggiamenti all’impianto.Se le protezioni non sono adeguatamente sicure, il progettistadeve informare l’utilizzatore finale nel Manuale di Istruzione.Si consiglia agli utilizzatori ed ai progettisti di prendere inconsiderazione

EN

DE

PL

ES

FR

IT

Dimensions in mm Projection/First angle

1 For 1 1/2” ported yokes add 5 mm 1 Two additional plugged G1/4 ports

6243

95

ø 20

1/4”

100

801

1/2”

108

29

1

3/2 Shut-off valve Porting block Silencer

A B C D Model

R1 23 138 51 51 MB008B

1 NPT 23 138 51 51 MB008A

C

Ø D

B

A