UVDI-360 Room Sanitizer
Advanced Ultraviolet Disinfection
UltraViolet Devices, Inc.
Proven to
Deliver No Touch Surface Disinfection
Reduce Hospital Acquired Infections
Improve Patient Outcomes
Designed and Manufactured by UVDI in California, USA
ISO 9001:2015ISO 14001:2015
UVDI EPA EstablishmentNumber 73542-CA-001
Designed and Manufactured by UVDI in California, USA
-
2UltraViolet Devices, Inc.
Why is Environmental Disinfection Important?
Environmental Contamination Leads to HAIs - the growing body of
evidence proves the hospital environment contributes to disease
transmission3
1.7 million HAIsoccur per year in acute-care hospitals,
resulting in $35 - $45 billion in healthcare costs annually5
Less than 50% of hospital room surfaces are adequately cleaned
and disinfected1
200% - 300% Greater Risk of infection if prior room occupant was
contaminated with an infectious pathogen4
Pathogens Surviveon surfaces from days to years2
C. Diff> 5 months
MRSA7 days to
12 months
VRE5 days to
> 46 months
5
https://www.beckershospitalreview.com/quality/how-hais-lead-to-direct-indirect-and-unintended-hospital-costs.html
1 Carling P. AJIC 2013;41:S20-S25
4 Otter, Yezli, French. ICHE. 2012;32:687-699
3 David J. Weber and William A. Rutala (2013). Understanding and
Preventing Transmission of Healthcare-Associated Pathogens Due to
the Contaminated Hospital Environment. Infection Control &
Hospital Epidemiology, 34, pp 449-452. doi:10.1086/670223.
2 Adapted from Hota B, et al. Clin Infect Dis 2004;39:1182-9 and
Kramer A, et al. BMC Infectious Diseases 2006;6:130
-
3
oz
one layer
UV-A
UV-B
Sun
ozone layer
UV-A
UV-B
UV-C
Sun
UV-C
T CC CT T T TT
AC GG AC A AG
UV-C
PHO
TONS
Delivers “No Touch” Surface Disinfection
The Effect of UV-C 254 nm Energy
UV-C energy alters the DNA of microorganisms preventing them
from reproducing and causing them to become non-pathogenic, or
incapable of causing disease.
UVDI-360 Room Sanitizer Produces Ultraviolet Germicidal
Radiation to Kill Microorganisms
UV-C Wavelength 200 nm - 280 nm • UV-C, which is produced
naturally in sunlight,
cannot penetrate the ozone layer
• UVDI-360 produces the same UV-C radiation through its
germicidal lamps
• Widely used for air, water and surface disinfection for
years
The 254 nm energy damages the DNA of the pathogens
PATHOGENS
-
4UltraViolet Devices, Inc.
LightweightOnly weighs 40 kg - durable and easy to move
Aluminum Reflector Mast Designed for maximum UV-C energy
distribution
Powerful 1.6 m Long Lamp TechnologyDesigned with four 1.6 m
maximum UV output lamps providing 360 degrees of UV radiation
Lamps are encapsulated with a special UV-transparent polymer to
contain glass in case of breakage
Touch Screen Easy and intuitive touch screen operating
system
Data RetentionSaves usage data for every cycle performed by
device
UVDI-360 Room Sanitizer
Safe to UseFour infrared motion sensors prevent operation if
movement is detected within the room
91 cm W
18
4 cm
H
Remote ControlDevice has a range of 15 m through walls
-
5
• Verifies that a specific UV-C dose has been received on a
target surface
• UV-C sensitive cards change color when exposed to UV-C energy.
The color change is calibrated to specific germicidal dose
levels
• Independent laboratory testing validated color change
associated with 2 log (99%) reduction for MRSA and C. difficile
• Used for establishing room disinfection protocols, quality
audits, training and record keeping
UV Dose Verify is calibrated and designed for exclusive use only
with the UVDI-360 Room Sanitizer and is not to be used with any
other UV disinfection device.
UV Dose Verify™ Technology
Device Serial No:
C-DIFF99% Kill
MRSA99% Kill
Date:Time:
Operator:
Cycle Time:
Target Location:
UV Dose Verify™Room or Unit No:
29-6077-01 Rev D
UNEXPOSED EXPOSED
Calibrated for exclusive use with UVDI’s disinfection
device.
UltraViolet Devices, Inc.
When closed, the case serves as a lamp protective case and
when
opened, the two halves of the case can be used separately as
two
independent warning signs.
2-in-1 Lamp Protective Case and
Warning Signs
Protective Case
Smart Data Web Portal
The UVDI-360 System features an optional robust website that
leverages data uploaded from your device.
• Provides analytical and diagnostic tools that help you
determine where, when, and how all your UV devices are working
Total Device Usage
Actual vs. Expected Rooms Treated
Cycle Time Per Room - Trend
Cycle Time Per Room - Aggregate
Cycle Interruptions
Lamp Life
Data Log
Upload Data
Dashboard
!
Parameters
UVDI-360 Smart Data ReportingWelcome
A
UltraViolet Devices, Inc.
English
-
6UltraViolet Devices, Inc.
Simple to Operate
Room Disinfection Protocols
The UVDI-360 Room Sanitizer delivers a programmed dose of UV-C
light to inactivate pathogens on hospital surfaces. After terminal
cleaning is complete, prepare the room for UV disinfection.
Depending on the room size, protocols may vary slightly. Below is
an example of a patient room prepared for UV disinfection.
Before Use
Follow the simple steps listed below to ensure a successful
outcome:
• Ensure bed rails are up and linens are removed from the
mattress
• Open all drawers and cabinet doors
Place the following objects in clear line of sight of the
UVDI-360 Room Sanitizer:
• TV Remote • Keyboard and Monitor • Bedside Table
• Call Button Device • Phone • Other High-touch Items
- David Pegues, MD, Professor of Medicine, Hospital of the
University of Pennsylvania (Leading teaching hospital in the
USA)
Position 1Typically 5 - 10
minutes
-
7
This UV-C device (UVDI) allowed room decontamination in 5 - 10
minutes
The UVDI-360 Room Sanitizer reduced C. difficile infection (CDI)
rates by 25% and prevented $134,568 — $191,604 annual direct
medical costs in Hematology/Oncology units
Efficacy and Performance
Microorganism Distance Time % Reduction Compared
to ControlLog Reduction
Compared to Control(meters) (minutes)
Methicillin-Resistant Staphylococcus aureus (MRSA) 2.44 3 >
99.999% > 5.69
Clostridium difficile (endospores) 2.44 5 99.992% 4.09
Escherichia coli (E. coli) (carbapenem-resistant; CRE) 2.44 5
99.9995% 5.33
Pseudomonas aeruginosa 2.44 5 99.9998% 5.7
Acinetobacter baumannii 2.44 5 99.9996% 5.38
Vancomycin-Resistant Enterococci (VRE) 2.44 5 99.997% 4.52
Ebola 2.44 5 99.9995% 5.26
Klebsiella pneumoniae 2.44 5 100% 5.4
Testing Conducted by a Third Party Lab in the USA*
Independent Laboratory Testing Efficacy
*Antimicrobial Test Laboratories, Round Rock, TX USA. December
2014
- Dr. William Rutala, Director, Hospital Epidemiology, The
University of North Carolina Health Care
- David Pegues, MD, Professor of Medicine, Hospital of the
University of Pennsylvania (Leading teaching hospital in the
USA)
UV-C technology implementation was associated with a 44%
reduction in viral infection incidence among pediatric patients in
a long-term care facility
- St. Mary’s Hospital for Children
“
“
“
“
“
“
@ = 99.992%reductionminutes
5 2.44meters
(endospores)
Outputs UV-C at 254 nm
C. diff
-
UltraViolet Devices, Inc.
uvdi.com • [email protected] • Phone: +1.661.295.8140 26145
Technology Drive, Valencia, California 91355 USA
Trusted History
Spanning three generations, a family owned business that
continues to look to the future
Technology Leadership
The people, experience and R&D assets driving
industry-leading innovation in UV disinfection
UVDI Offers A Broad Range of UV Devices for Multiple
Applications
Surfaces
Mobile UV devices for disinfection of hospital rooms. Currently
used in hundreds of hospitals worldwide
Air
UV air and coil disinfection products installed in over 1,000
hospital HVAC systems
Water
Providing millions of people worldwide with safe, clean water
disinfected by UV
Bringing over 70 years of Experience in UV Technology
twitter.com/uvdi
MKT
FM 3
13 R
ev H
060
320
ENG
Rapid Growth
Serving many countries around the world
SPAIN
GREECE
SLOVENIA
CROATIA
ROMANIA
CZECH REPUBLIC
HUNGARY
SOUTH AFRICA
EGYPT
TURKEY
SAUDI ARABIA
UNITED ARAB EMIRATES (UAE)
USA
CANADA
MEXICO
CHILE
ECUADOR
URUGUAY
UNITED KINGDOM
GERMANY
THE NETHERLANDS
SCANDINAVIA
SWITZERLAND
BELGIUM
ISRAEL
QATAR
INDIA
JAPAN
HONG KONG
SINGAPORE
Inte
rnational Growth