Top Banner
Applied Technology Development Division UV/VIS SPECTROPHOTOMETER MECASYS, Co., Ltd.
25

UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Jan 12, 2019

Download

Documents

buikhue
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

UV/VIS SPECTROPHOTOMETER

MECASYS, Co., Ltd.

Page 2: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

What is UV/VIS?What is UV/VIS?

� Electromagnetic Spectrum

X-Rays UV VIS NIR IR Micro wave

200nm 400nm 700nm 2500nm 500 µm

E0

E1

∆E= E1 -E0

Molecular rotationMicro Wave

Molecular vibrationIR

Outer ElectronUV/VIS

Inner ElectronX-Rays

Type of TransitionType of Radiation

Page 3: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Principle of UV/VIS SPECTROPHOTOMETERPrinciple of UV/VIS SPECTROPHOTOMETER

� Principle

• Light Intensity Change : By Absorbance or Transmittance

•Quantity : Using Absorbance

λ

I

λ

I

Sample

Page 4: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

LambertLambert--BeerBeer’’s Laws Law

� Transmittance, t

• Ι t / Ι 0 = t

� Absorbance, A

• log 1 / t = A

� Lambert – Beer’s Law

• A = abC, A = ξbC

� b : Sample Path length, C : Sample Concentration,

� a : Absorbance Constant

� ξ : Molecular Absorbance Constant

I0 It

Sample (Conc.C)

Path length b

Page 5: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Standard Curve, Calibration curveStandard Curve, Calibration curve

� Lambert-Beer’s Law

• A=abC

• Concentration determination of Sample

Conc.Conc.Conc.Conc.

AbsorbanceAbsorbanceAbsorbanceAbsorbance

Standard Curve

� Standard Curve

• Standard Samples

• Proportional constant

• Absorbance measurement of

Samples

Concentration

determination of Sample

Page 6: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

� Deviations in absorptivity coefficients

• at high concentrations (>0.01M) due to electrostatic interactions

between molecules in close proximity

� Scattering of light

• due to particulates in the sample

� Fluorescence or Phosphorescence of the sample

� Changes in refractive index at high analysis concentration

� Shifts in chemical equilibria as a function of concentration

� Stray light

Limitation of LambertLimitation of Lambert--BearBear’’s Laws Law

Page 7: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Application of Application of UV/VIS SpectrophotometerUV/VIS Spectrophotometer

Quantity analysisQuantity analysisQuantity analysisQuantity analysis

(Using a Spectrum)

Quality analysisQuality analysisQuality analysisQuality analysis

(Standard Curve)

Chemical analysis

Food safety analysis

Blood analysis

DNA/RNA Conc. analysis

Residual Pesticide analysis

Residual chlorine analysis

Page 8: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Functions of SpectrophotometerFunctions of Spectrophotometer

� ABS/%T/CONC

• Measuring Absorbance/Transmittance/Concentration

� Survey Scan

• Measuring Absorbance(Transmittance) Spectrum

� Standard Curve (Calibration Curve)

• Determining Proportional Constant between ABS and Conc

� Simple Kinetics

• Measuring Time Dependent ABS Variation

� ABS Ratio

• Measuring ABS Ratio (DNA/Protein)

Page 9: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Structure of UV/Visible SpectrophotometerStructure of UV/Visible Spectrophotometer

Light

source

Lens

or

Mirror

MonochromatorDetector

Sample

Page 10: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

ExampleExample

Spectrophotometer

Light

SourceMonochromator

Sample

Compartment

Sensing

Part

Page 11: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Light SourceLight Source

� Deuterium Arc Lamp

• UV Region

•Wavelength Range :

190~420nm

� Tungsten LampTungsten LampTungsten LampTungsten Lamp

• Wavelength Range : Part of the UV and the whole of the Visible Wavelength Range : Part of the UV and the whole of the Visible Wavelength Range : Part of the UV and the whole of the Visible Wavelength Range : Part of the UV and the whole of the Visible

range range range range ((((약약약약350 ~ 2,500350 ~ 2,500350 ~ 2,500350 ~ 2,500nm)nm)nm)nm)

� Xenon Lamp

• Wavelength Range : 190~800nm

Tungsten LampTungsten LampTungsten LampTungsten Lamp

Page 12: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

MonochromatorMonochromator

� Accepts polychromatic input light from a lamp and outputs

monochromatic light

� Components : Entrance slit, Dispersion device, Exit slit

Entrance slit

Exit slit

Dispersion device

White Light

Monochromatic

Light

Page 13: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Dispersion Device (I)Dispersion Device (I)

� Filter

• Absorptive Filter

• Interference Filter : FWHM 10

– 50 nm

Page 14: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Dispersion Device (II)Dispersion Device (II)

� Prism

Page 15: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Dispersion Device (III)Dispersion Device (III)

� Grating

• Plane Grating, Concave Grating

Page 16: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Monochromator structureMonochromator structure

Littrow mounting

Slit

Grating

Mirror

Czerny-turner mounting

Mirror Mirror

Grating Entrance

slit

Exit slit

Page 17: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Monochromator Design Monochromator Design

� Modified Czerny-Turner Type

- Focal Length : 200mm

- Sine Drive Mechanism

- 1nm Bandwidth

� Czerny-Turner Type

- Focal Length : 100mm

- Direct Drive Mechanism

- 4nm Bandwidth

Page 18: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Absorption CellAbsorption Cell

� Receptacle for Sample.

� Material

• Quartz, Fused Silica(Using over

190nm)

• Glass (Using Over Visible Region)

Page 19: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

DetectorDetector

� Photodiode

� Photodiode & CCD

� PMT(Photo Multiplier tube)

Page 20: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Type of Type of UV/VIS SpectrophotometerUV/VIS Spectrophotometer

• Single Beam Type • Double Beam Type

Page 21: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Type of Type of UV/VIS SpectrophotometerUV/VIS Spectrophotometer

Grating

Light Sample

Detector

� Scanning type : � PDA type :

Grating

Light

Multi channel

DetectorSample

Page 22: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Specifications ExampleSpecifications Example

� Spectral Bandwidth : 1 nm

� Wavelength

• Range : 190 – 1100 nm

• Accuracy : ± 0.5 nm

• Reproducibility : ± 0.1 nm

� Photometric

• Range : -0.3 – 3.0 Abs (0 – 125 %T)

• Accuracy : < 1% at 1 Abs

• Reproducibility : ± 0.001Abs

� Stray Light : <0.05% at 220 nm & 340 nm

Page 23: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Accessories (I)Accessories (I)

� Multi-Cell Holder � Sipper System

Page 24: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Accessories (II)Accessories (II)

� Micro Volume Cell � Round Cell � Long Path Cell

� Temperature Cell Holder, Film/Thin-Layer Holder

Page 25: UV VIS Spectrophotometer ̷ .ppt [ б ]) · Czerny-turner mounting Mirror Mirror Grating Entrance slit Exit slit. Applied Technology Development Division Monochromator Design Modified

Applied Technology Development Division

Thank You!