Page 1: UV signal lossesand straylight by chemicalcontamination ...

UV signal losses and straylightby chemical contamination

Pierre ETCHETO, Delphine FAYE, CNES

Xueyan ZHANG, IAS

COMET RTS contamination, Toulouse Dec. 11th 2018

Page 2: UV signal lossesand straylight by chemicalcontamination ...

Contamination issues for Space UV optics

UV losses and straylight by chemical contamination Dec. 11th 2018

� Molecular contamination very critical for UV instrumen ts

� Loss of reflection / transmission + spectral shift

� Straylight by scattering (drops, droplets..,)

� Ageing

� Condensation on optical components

� On ground : manufacturing, AIT, transport, storage, on launch pad. UV optics cannot be cleaned!

� During launch : outgassing + re-condensation on (cold) optics and detectors

� In flight : ageing (under Sun UV, radiations, atox, thermal cycling… ).

Few data available to build contamination requirements + cleanliness plans

⇒ CNES + IAS R&T (2014-2017) for Solar Orbiter / EUI :

Try to assess effects of molecular contamination on scatter and transmission in the EUV (17-30 nm) and FUV (100-200 nm)

2

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

Page 3: UV signal lossesand straylight by chemicalcontamination ...

Outline of experiment(1) spectral losses a Lyman alpha(2) scatter in EUV

Samples tested : o (Lyman α) filters (MgF2 substrates) o (EUV) Mirrors (Al/Mo/Sic coating on SiO2 substrates)o (EUV) Filters (Al sheet on hexagonal grid)

Contaminants tested : outgassing products from typical Space contaminantso Scotchweld EC2216 epoxy resino RTV-566 Silicone elastomero M55J/RS-3C Carbon fiber-polycyanate resin composite honeycomb

Sequence :

o Measure all clean samples (transmittance and BRDF) + setup signature

o Contaminate samples with 2-3 levels of the 3 contaminants

o Measure samples again and check clean references

3

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 4: UV signal lossesand straylight by chemicalcontamination ...

Contamination process

� Samples exposed in CNES oven

o 4 days at 10-4 mbar / 100°C

o Several quantities of chosen contaminants => outgassing + condensation

o Quantity assessment by micro-weighting before and after

� Contamination levels obtained

o Composite honeycomb : 10 and 20 µg /cm2 (mirrors).

o EC2216 : Below measurement error (disturbed by water adsorption / desorption)

o RTV Silicone : 20-120 µg /cm2

Contamination level control : major issue . All we have today are orders of magnitude

4

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 5: UV signal lossesand straylight by chemicalcontamination ...

Molecular contamination aspect

Condensation of contaminants depends on :

o Sample surface state (Wettability)

o Sample temperature

o Sample exposure to evaporate contaminants…

⇒ Drops, droplets, RARELY uniform film

⇒ Strong effect on absorption (in drops) and on scatter

EC2216 contamination : Droplets and Drops =>

Silicone contamination : Droplets and drops =>

5

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 6: UV signal lossesand straylight by chemicalcontamination ...

Lyman αααα Contaminated samples

6

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 7: UV signal lossesand straylight by chemicalcontamination ...

Lyman αααα transmittance facility

SOLEIL synchrotron, APEX line :

• energy range : 1 - 20 eV (60 - 300 nm)

• spectral resolution : 0.1 nm

• beam size : about 4 x 4 mm² (split in 2 spots)

• detector : IRD AXUV100 photodiode +transimpedance amplifier

• MgF2 window : to cut spectral harmonics below 115 nm

• Measurements at 2 locations on sample : � centre + 2 mm off centre (to check non-

uniform cibtmination)

7

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 8: UV signal lossesand straylight by chemicalcontamination ...

Exposure of contamination to flux

• 13 -14 h (EC2216 and composite) : below

• 2h30 (Silicone)

⇒ Notable change in aspect and drop of transmittance

8

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 9: UV signal lossesand straylight by chemicalcontamination ...

Effects of EC2216 at Lyman αααα

9

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 10: UV signal lossesand straylight by chemicalcontamination ...

Effects of honeycomb resin at Lyman αααα

10

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 11: UV signal lossesand straylight by chemicalcontamination ...

Effects of silicone at Lyman αααα

11

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 12: UV signal lossesand straylight by chemicalcontamination ...

EUV : Scatter vs peak transmission

Contaminated BRDF vs. Clean BRDF and signature

Scatter depends on both surface state an specular T/R :

o Direct comparison with signature shows component T/ R and actual scatter

o Comparison between contaminated and clean shows T/R loss and actual scatterchange

o Comparison between normalised clean and contaminated shows scatter to specular ratio, ie. straylight ratio

12

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 13: UV signal lossesand straylight by chemicalcontamination ...

EUV Scatter measurement facility� Soleil synchrotron « Metrology » XUV beamline : both EUV spectrum and BRDF

Angle-resolved scatter (BSDF) configuration

o Wavelength 17.4 nm (72 eV)

o Beam 0.1 x 0.2 mm, divergence negligible

o Detector : Si photdiode + 1.5 mm pinhle, on 287.5mm long arm

o Incidence 0° (for transmitting filters) / 6° (for mirrors)

o Measuring range : +/- 3°

13

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Vacuum chamber

Page 14: UV signal lossesand straylight by chemicalcontamination ...

EUV References and signature

Checks :

o Check beam centering on samples : scan => uniform area (inside a stitch for grid filters)

o Measure and substract dark signal

o Signature (direct beam over +/-4°)

o Measure clean samples + compare with signature

Results :

o Signature : specular peak, width : +/-0.5° at 10-4, +/-0.7° at 10-5. Peaks 10-4 high at +/-3.5°, due to reflections on slitchamfers. Not critical : falls outside the samples => absorbed by sample holder

o Clean samples : specular peak + scatter. On mirrors, strong dispersion depending on sample roughness

14

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

Signature and clean mirror samples

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 15: UV signal lossesand straylight by chemicalcontamination ...

EUV : Results on EC2216-contaminated mirrors

MA-1 (strong level, unknown) :

Scatter x10 scatter at all angles

MA-2 (slightly higher level, unknown) :

Contaminated scatter slightly higher than MA-1. Clean scatter very high

=> Significant scatter increase (even whenmasked by strong clean scatter)

15

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 16: UV signal lossesand straylight by chemicalcontamination ...

EUV : Results on composite-contaminated mirrors

MC-1 (10 µg/cm2) :

x10 scatter near specular, then drops to clean scatter (medium level)

MC-2 (20 µg/cm2) :

x20 scatter close to specular,then slightlyabove clean scatter (similar to MC-1)

⇒Significant scatter increase.

⇒Linear relationship with contam. Level?

16

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 17: UV signal lossesand straylight by chemicalcontamination ...

EUV : Results on EC2216-contaminated filters

=> Those levels of EC2216 contamination cause little scatter.

17

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

FA-1 (7,35 µg/cm²) :

Scatter similar to clean scatter : few, small droplets

FA-2 (60 µg/cm²) :

Scatter similar to FA-1, but clean scatter much lower

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 18: UV signal lossesand straylight by chemicalcontamination ...

EUV : Results on composite-contaminated filters

=> No significant effect of contamination

18

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

FC-1 (58 µg/cm²) :

Scatter similar to clean scatter (rather high)

FC-2 (52 µg/cm²) :

Scatter similar to clean scatter (medium level)

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 19: UV signal lossesand straylight by chemicalcontamination ...

EUV : Results on Silicone-contaminated filters

FS-1 (50 µg/cm²) :

Scatter not increased, but specular peaknarrowed

FS-2 (69 µg/cm²) :

Scatter slightly increased + specular peakmore narrowed

=> Non-scatter effect : focusing by drops?

19

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 20: UV signal lossesand straylight by chemicalcontamination ...

EUV : Results on heavily Silicone-contaminated filters

FS-3 ( 117 µg/cm 2) :

Measurements on droplets alone areas and aiming at large drop

Droplets :

• Slightly reduce transmission

• Specular shape unchanged

• Increased scatter

Drops :

• drastically reduce signal (high local contaminant thickness)

• Specular beam strongly narrowed (lenseffect ?)

• Scatter +/- similar to droplets

⇒Drops combined with droplets?

20

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018

Page 21: UV signal lossesand straylight by chemicalcontamination ...

ConclusionsFirst exploration of yet poorly known effects : It confirms how critical molecular contamination is fo r UV instruments.

Signal loss at Lyman α α α α (peak) :

o 40% (EC2216) => 60% (13h under flux)o 25-80% (composite, depending on droplet size) => 85% (14h under flux)o 75-97% (Silicone, depending on droplets) => opaque (2.5h under flux)

Signal loss at 17.4nm (peak) :

o 10-25% (EC2216 and composite)o 25-50% (Silicone) especially through large drops

Noticeable scatter increase:

o Especially on mirrors (EC2216 and composite), o Much less on filters (except heavy Silicone contamination)o Can be blurred by strong scatter of clean component (manufacturing dispersion)o Non-scatter effect : narrowing of specular beam by drops (lens effect ?)

Trouble in assessing contamination levels (EC2216) : o Water adsorption / desorption disturbs micro-weigh measurementso Non-reproducible behaviour between sampleso Comparison with Alu samplesmay not be relevant

⇒ More effort needed in assessing contamination levels a nd process

21

Direction des Systèmes Orbitaux – sous-direction des Systèmes Instrumentaux

UV losses and straylight by chemical contamination Dec. 11th 2018