NOTE: This drawing is shown for illustrative purposes only and is NOT a part of the proposed construction set. Original Architect retains copyright of all images shown this sheet Notes added this sheet 02-14-2020 are shown in red italics and not part of original drawing ENTRANCES TO RESIDENTIAL UNITS CONSOLIDATED INTO TWO ENTRY POINTS CONCRETE STOOPS / EXTERIOR STEPS ELIMINATED RAMP AND PLANTER BOXES ELIMINATED DINING TERRACE ADDED THIS AREA ENTRANCE MOVED TO MAIN STREET BIFOLD DOOR ADDED THIS WALL FOR TERRACE ACCESS ELEVATOR ELIMINATED UTILITY CORRIDOR ELIMINATED PARKING DEPTH INCREASED TO 18'-6" RAMP LENGTH REDUCED DUMPSTER AND TRANSFORMER PAD CLEARANCE INCREASED RESIDENTIAL GARAGES ADDED (2) STAIRWAY RELOCATED TO COURTYARD CRAWL SPACE BELOW PROPOSED GARAGES ELIMINATED BASEMENT ACCESS RELOCATED BASEMENT ENTRANCE ELIMINATED RESTROOMS REDESIGNED
16
Embed
UTILITY CORRIDOR ELIMINATED BASEMENT ACCESS RELOCATED · 2012 International Building code 2009 International Energy Code Town of Frisco Amendments TYPE OF CONSTRUCTION Type VN (Sprinklered)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
NOTE:This drawing is shown for illustrative purposes onlyand is NOT a part of the proposed construction set.Original Architect retains copyright of all images shown this sheetNotes added this sheet 02-14-2020 are shown in red italics and notpart of original drawing
ENTRANCES TO RESIDENTIAL UNITSCONSOLIDATED INTO TWO ENTRY POINTSCONCRETE STOOPS / EXTERIOR STEPS ELIMINATED
RAMP AND PLANTER BOXES ELIMINATEDDINING TERRACE ADDED THIS AREA
ENTRANCE MOVED TO MAIN STREET
BIFOLD DOOR ADDED THIS WALL FOR TERRACE ACCESS
ELEVATOR ELIMINATED
UTILITY CORRIDOR ELIMINATED
PARKING DEPTH INCREASED TO 18'-6"
RAMP LENGTH REDUCED
DUMPSTER AND TRANSFORMER PAD CLEARANCE INCREASED
RESIDENTIAL GARAGES ADDED (2)
STAIRWAY RELOCATED TO COURTYARD
CRAWL SPACE BELOW PROPOSED GARAGES ELIMINATED
BASEMENT ACCESS RELOCATED
BASEMENT ENTRANCE ELIMINATED
RESTROOMS REDESIGNED
ENTRANCE RELOCATED TO MAIN STREET
SECOND FLOOR COMMERCIAL DECK ELIMINATED
EXISTING STRUCTURE REMOVEDREPLACED WITH PROPOSED COMMERCIAL SPACE ANDRESIDENTIAL GARAGES (2)
ROOF HEIGHT LOWERED TO 35'-0" MAX
CURVED METAL ROOFS ELIMINATED
EXISTING TO REMAIN
ROOF HEIGHT LOWERED TO 35'-0" MAX
CURVED METAL ROOFS ELIMINATED
ENTRANCE RELOCATED TO MAIN STREET
BIFLOD DOOR SYSTEM ADDED THIS ELEVATION
COMMERCIAL ROOF DECK ELIMINATED
SECOND FLOOR COMMERCIAL DECK ELIMINATED
COMMERCIAL ROOF DECK ELIMINATED
ENTRANCES TO RESIDENTIAL UNITSCONSOLIDATED INTO TWO ENTRY POINTSCONCRETE STOOPS / EXTERIOR STEPS ELIMINATED
COMMERICAL SPACE AND DECK ADDED OVERPARKING SPACES
END RESIDENTIAL UNIT EXPANDED THIS AREA
EXISTING COMMERCIAL SPACE THIS AREAREPLACED WITH NEW CONSTRUCTION
VAULT ELIMINATED
RAMP LENGTH REDUCED
FINISH GRADE IN COURT REDUCED IN HEIGHTAPPROX 12"
NOTE:This drawing is shown for illustrative purposes onlyand is NOT a part of the proposed construction set.Original Architect retains copyright of all images shown this sheetNotes added this sheet 02-14-2020 are shown in red italics and notpart of original drawing
1. Strip existing topsoil from site in construction areas and stockpile topsoilfor landscape use
2. General contractor shall remove all debris, stumps, slash, concreteasphalt, etc, form site prior to landscape work.
3. Disturbed areas on site shall receive a minimum of 3” – 4” of topsoil inpreparation for landscape treatment.
4. Seed disturbed area where needed with short dry grass mix. Applystarter fertilizer (18-46-0) or equivalent @ 4 lbs/1000 sf sow grass mix @2 lbs/1000 sf. Rake materials into soil.
5. Cobble rock or rock from site may be used as a ground cover treatmentin designated areas with weed barrier fabric. Approximately 3”-6”diameter
6. Boulders recovered during construction (2’ and larger in diameter) to bestockpiled on site. When placed, bury 1/3 to ½ of each boulder.
7. Locate all plant material to avoid snow shed, snow removal locations,sight lines. Utility lines, and easements.
8. All new plants shall be placed under an automatic drip irrigation system.
9. All plant material shall be back filled with 1/3 topsoil, 1/3 manure, 1/3compost and mixed 50/50 with native soils.
10. All shrub beds and tree wells shall receive a minimum of 3 inchesshredded bark mulch
11. All newly planted trees shall be root fed at the time of installation. Rootfeeding shall consist of a liquid root growth stimulator, or soluble fertilizerat recommended rate of 1 tbs per 1 gallon of water.
12. All landscaping shall be maintained and dead trees shall be replacedwithin one year.
BUILDING CODES2012 International Building code2009 International Energy CodeTown of Frisco Amendments
TYPE OF CONSTRUCTIONType VN (Sprinklered)3-Story + Basement
EXISTING COMMERCIAL SPACEEXISTING COMMERCIAL SPACEAREA OF PROPOSED REMODEL
GR
AN
ITE
STR
EE
T A
LLE
Y
MA
IN S
TRE
ET
HOTEL FRISCO
BAGALI'S RESTAURANT / FRISCO MARKETPLACE CONDOS
8" W
ater
Gas
18" P
erfo
rate
d S
torm
Sew
er
8" V
CP
San
itary
Sew
er
+9151.00
EXISTING COMMERCIAL BUILDING TO BE REMOVED
Existing BreezewayBldg Structure Above To Be RemovedSee Structural Plans for Demolition Notes@ Tie-in to Existing ConstructionExisting Walkway (2-Levels) and Roof Above to Remain
This Area Removed Prior toRevised Site Plan Application 03-31-20
This Area to be Removed w/Revised Site Plan Application
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20DOWN
UP
Cus
tom
Tex
t
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20DOWN
UP
Cus
tom
Tex
t
1
2
3
4
5
6
7
8
9
10 11
12
13
14
15
16
17
18
19
20DOWNUP
Cus
tom
Tex
t
1
2
3
4
5
6
7
8 9
10
11
12
13
14
15
16
17DOWNUP
Cus
tom
Tex
t
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19DOWN
UP
Cus
tom
Tex
t
9 1/
2"26
'-1"
5 1/
2"
93'-7 1/2" 42'-10 1/2"
18'-6"
3'6'
13'-6
1/2
"5
1/2"
40'
80'
2'-10" 3'-6"
6'-4"
204.42 sq ft
MATERIALS STAGING
GA
S M
ETE
R
REFUSE ENCLOSURE
TRANSFORMER
MEN
WOMEN
DF
STORAGE / JANITORLANDCAPING
EXISTING COMMERCIAL SPACEEXISTING COMMERCIAL SPACEAREA OF PROPOSED REMODEL
GR
AN
ITE
STR
EE
T A
LLE
Y
MA
IN S
TRE
ET
HOTEL FRISCO
BAGALI'S RESTAURANT / FRISCO MARKETPLACE CONDOS
8" W
ater
Gas
18" P
erfo
rate
d S
torm
Sew
er
8" V
CP
San
itary
Sew
er
+9052.58 FF
+9053.58 FF
+9052.58 FF
+9052.58
+9151.00
DUMPSTER
PORTABLE TOILET
8' Tall Plywood Construction Barrier
8' T
all P
lyw
ood
Con
stru
ctio
n B
arrie
r
Construction Activity w/Controlled Access
Public Access
PROPOSED BUILDING
Area Shown is ApproximateSubject to Revision During Construction6'-0" Hi Chain Link Fence at Perimeter w/ Gate Access
Temporary Signage on Construction Barrier toComply w/ Town of Frisco Sign Code
General Contractor to comply with Applicable Codesfor Encroachments into the Public Right-of Way andTown of Frisco Requirements
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
TUBE ARCHITECTURAL DS-CD05LED Ceiling Mounts
ORDERING NUMBER
Diameter Watt BeamBeam Angle Color Temp CRI Lumens CBCP
Efficacy (Lm/W) Light Distribution Finish
DS-CD05 25W
SSpot 16°
92727930303540
2700K 2700K3000K 3000K3500K4000K
908590858585
BKWTBZGH
BlackWhiteBronzeGraphite
NNarrow 25°
92727930303540
2700K 2700K3000K 3000K3500K4000K
908590858585
FFlood 33°
92727930303540
2700K 2700K3000K 3000K3500K4000K
908590858585
PRODUCT DESCRIPTION
The latest energy efficient LED technology in an appealing cylindrical profile delivers accent lighting. Comes in various light beam angle options.
SPECIFICATIONS
Input: Dimming:
Light Source:
Finish:
Standards:
Operating Temp:
Universal voltage 120V - 277VAC, 50/60Hz Electronic low voltage (ELV) : 100% - 5% 0-10V: 100% - 1% High output 3 Step Mac Adam Ellipse COB Rated life of 60,000 hours at L70Electrostatically powder coated, white, black, bronze and graphiteIP65 rated, ETL & cETL wet location listed, Energy Star® 2.2 rated Title 24 JA8-2016 Compliant -13°F to 122°F (-25°C to 50°C)
DS-CD05-_____-___
Example: DS-CD05-N927-BK
FEATURES
• High performance exterior rated LED ceiling light• Solid aluminum construction• 39° visual cutoff angle or glare control• 5 year warranty
78”
4d”
18252190 1895 2300 2350 2375
1005012057 10427126441293713062
738876929495
18102170188022752330 2350
52806335 5478 664367976863
728775919394
190022801970239024452470
451554174685568158125870
769179969899
DS-CD0517 17W
1Reference output shows 25W output. Multiply by 0.7 to determine output for 17W combinations.
Reference Output 1
Fixture Type:
Catalog Number:
Project:
Location:
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. SEPT 2019
Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center1600 Distribution CtLithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
TUBE ARCHITECTURAL DS-WS05LED Wall Mounts
ORDERING NUMBERDiameter Watt
BeamBeam Angle Color Temp CRI Lumen
Efficacy (lm/w) Light Distribution Finish
DS-WS05 5” 25W
SStraight up or down
16°
927S27S930S30S35S40S
2700K2700K3000K3000K3500K4000K
908590858585
BKWTBZGH
BlackWhiteBronzeGraphite
NStraight up or down
25°
927S27S930S30S35S40S
2700K2700K3000K3000K3500K4000K
908590858585
FStraight up or down
33°
927S27S930S30S35S40S
2700K2700K3000K3000K3500K4000K
908590858585
FAway from the wall
N/A
927A27A930A30A35A40A
2700K2700K3000K3000K3500K4000K
908590858585
FTowards the wall
N/A
927B27B930B30B35B40B
2700K2700K3000K3000K3500K4000K
908590858585
PRODUCT DESCRIPTION
The latest energy efficient LED technology in an appealing cylindrical profile delivers accent and wall wash lighting. Comes in various light distribution and beam angle options.
FEATURES
• High performance exterior rated LED wall mount light• Fixture can install upside down to alter light distribution• Solid aluminum construction• 5 year warranty
DS-WS05-______-___
Example: DS-WS05-F930A-WT
SPECIFICATIONS
Input: Dimming:
Light Source:
Finish:Standards:
Operating Temp:
Universal voltage 120V - 277VAC, 50/60HzElectronic low voltage (ELV) : 100% - 5% 0-10V: 100% - 1%High output 3 Step Mac Adam Ellipse COB Rated life of 60,000 hours at L70Electrostatically powder coated, white, black, bronze and graphite IP65 rated, ETL & cETL wet location listed, Energy Star® 2.2 rated Title 24 JA8-2016 Compliant-13°F to 122°F (-25°C to 50°C)
4d”2w”
78” 5”
182521901895230023502375
100501205710427126441293713062
738876929495
181021701880227523302350
528063355478664367976863
728775919394
190022801970239024452470
451554174685568158125870
769179969899
200024002075252025752600
N/A
809683101103104
2000 24002075252025752600
N/A
809683101103104
CBCP
DS-WS0517 5” 17W
1Reference output shows 25W output. Multiply by 0.7 to determine output for 17W combinations.