Top Banner
Device C C USB Control from PC Custom Cables EX350 Analyzer A B A host C B C Gnd CC Vconn SBU1 & 2 SSTX2/RX2 Shield Vbus Gnd D+/D- SSTX1/RX1 Shield Analyzer 1 PC Running Analyzer SW
12

USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

Nov 14, 2018

Download

Documents

phamthuy
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

Device C C

USB Control from PC

Custom Cables

EX350 Analyzer

A B

A

host C

B

C

Gnd CC

Vconn SBU1 & 2

SSTX2/RX2 Shield

Vbus Gnd

D+/D- SSTX1/RX1

Shield

Analyzer

1

PC Running Analyzer SW

Page 2: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

UUT C

EX350 Generator (EXAMINER)

A B

C

PC Running Examiner

or Generator SW and Analyzer SW

USB Control from PC

Custom Cable

A

EX350 Analyzer

A B

A

B

B

CC

GND

STD-A to STD-B (for Vbus)

2

Examiner or Generator with Analyzer Setup for USB Host-capable UUT

Vconn

Page 3: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

UUT A

EX350 Generator (EXAMINER)

A B

A

PC Running Examiner

or Generator SW and Analyzer SW

USB Control from PC

A

EX350 Analyzer

A B

A

B

B

STD-A to STD-B

3

Examiner or Generator with Analyzer Setup for USB Host-capable UUT

With Std-A connector

STD-A to STD-B

Page 4: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

UUT C

EX350 Generator (EXAMINER)

A B

C

PC Running Examiner

or Generator SW and Analyzer SW

USB Control from PC

Custom Cable

A

EX350 Analyzer

A B

A

B

B

CC

GND

STD-A to STD-B (for Vbus)

4

Examiner or Generator with Analyzer Setup for USB Device-capable UUT

Vconn

Page 5: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

UUT B

EX350 Generator (EXAMINER)

A B

B

PC Running Examiner

or Generator SW and Analyzer SW

USB Control from PC

STD-A to STD-B

A

EX350 Analyzer

A B

A

B

B

STD-A to STD-B (for Vbus)

5

Examiner or Generator with Analyzer Setup for USB Device-capable UUT

With Std-B Connector

Page 6: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

Device C C

Type-C to Type-C Adapter

EX350 Analyzer

A B

Device C C C C GND GND GND

VBUS CC1 CC2

Ellisys Type-C Breakout Rev A

Dn Dp

SBU2

SBU1

C C

CC GND

6

USB Control from PC

PC Running Analyzer SW

Alternate Approach for Analyzer

Info: orientation must be determined manually

Page 7: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

Device C

EX350 Generator (EXAMINER)

A B

C

Custom Cable

A

USB Control from PC

7

Examiner or Generator (without Analyzer) for USB Host-capable UUT

PC Running Examiner or Generator SW

(No Analyzer)

Page 8: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

Device C

EX350 Generator (EXAMINER)

A B

C

Custom Cable

A

USB Control from PC

8

Examiner or Generator (without Analyzer) for USB Device-capable UUT

PC Running Examiner or Generator SW

(No Analyzer)

Page 9: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

Device

EX350 Analyzer

A B

A

Host C

B

C GND GND GND

VBUS CC1 CC2

Ellisys Type-C Breakout Rev A

Dn Dp

SBU2

SBU1

C C C

Type-C to Type-C Adapter

Captive

9

Captive Cable Approach

USB Control from PC

PC Running Analyzer SW

C

Info: orientation must be determined manually

Page 10: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

DP Sink (dongle)

EX350 Analyzer

A B

A

DP source

B

GND SBU1 SBU2

VBUS CC1 CC2

Ellisys Type-C Extender Rev A

Dn Dp C C

Type-C to Type-C Adapter

Captive

10

Analzying DP Alt mode without blocking video signal

USB Control from PC

PC Running Analyzer SW

C

Info: orientation must be determined manually

C-plug

C-receptacle

C

C-plug

C-receptacle CC

GND

Vconn

Note: A and B USB ports are not used on EX350, since they do not pass DP data

Note: in Analyzer mode, these 2 headers are electrically connected either one may be used for CC, VCONN, and GND connection

Page 11: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

EX350 Generator (EXAMINER)

A B

PC Running Examiner

or Generator SW and Analyzer SW

USB Control from PC

Custom Cable

A

EX350 Analyzer

A B

A

B

B

CC GND

STD-A to STD-B (for Vbus, opt.)

11

Generator with E-Marked Cable

VConn

GND GND GND

VBUS CC1 CC2

Ellisys Type-C Breakout Rev A

Dn Dp

SBU2

SBU1

C C C C C

E-Marked Cable

Type-C to Type-C Adapter

Info: orientation must be determined manually

Page 12: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB

Type-C to Type-C Cable

EX350 Analyzer

A B

Device C C C

CC

GND

12

USB Control from PC

PC Running Analyzer SW

Analyzer Passive Tapping to Board UUT

Device

CC GND

C