The EuP Directive, passed by the European Parliament and the Council of the European Union on July 6th 2005, establishes a framework of rules and criteria for setting requirements on the ecodesign of energy using products (EuPs). The directive’s goal is to reduce the environmental impact of energy using products and support sustainable development in a variety of ways and across a number of different product categories — such as standalone circulator pumps for domestic and commercial buildings. In 2013, the EuP Directive will change the stand alone circulator market in Europe permanently and installers who don’t already choose energy efficient circulators will no longer have a choice. The ecodesign for glandless stand alone circula- tors will be part of the Declaration of Conformity (CE) and without a CE mark products may not be sold in the EU. By 2015, all circulators sold in the EU will have to meet or exceed even more stringent energy-efficiency requirements. [email protected]2013 Ecodesign Pump Groups UPONOR PUSH 12 TH UPONOR PUMP GROUP VPG-10 UPONOR PUMP GROUP PPG-20 UPONOR PUMP GROUP PPG-30 UPONOR COMPACT CONTROL V5 HTG PACKS SPARE PARTS & PUMPS
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
The EuP Directive, passed by the European Parliament and the Council of the European Union on July 6th 2005, establishes a framework of rules and criteria for setting requirements on the ecodesign of energy using products (EuPs). The directive’s goal is to reduce the environmental impact of energy using products and support sustainable development
in a variety of ways and across a number of different product categories — such as standalone circulator pumps for domestic and commercial buildings.
In 2013, the EuP Directive will change the stand alone circulator market in Europe permanently and installers who don’t already choose energy efficient circulators will no longer have a choice. The ecodesign for glandless stand alone circula-
tors will be part of the Declaration of Conformity (CE) and without a CE mark products may not be sold in the EU. By 2015, all circulators sold in the EU will have to meet or exceed even more stringent energy-efficiency requirements.
Features� Compact water and room temperature control pump unit� Ideal for smaller under�oor heating areas served by one loop only� 2m long capillary sensor for remote room temperature control� 12 to 28°C room temperature regulation� Left or right hand installation mounting bracket� 230V mains power� 55°C maximum secondary water temperature� 2 x 15mm copper primary connections� Maximum 3kW output� Optional wired room thermostat control using actuator 1022244, shown below
PRODUCT CODE 1059834
Power consumption was 25 watts, now only 8 watts.
1059842 - UPONOR COMPACT CONTROL PACK V5
Features� Fixed water temperature control pump unit� 6m ‘A’ rated pump� Complete with �ll and vent points� High limit water temperature thermostat� ¾” Primary isolation and regulation valves� Ideal for direct coupling to Uponor TM manifolds for multi loop systems� 20 to 65°C secondary water temperature regulation� Left and right hand connection possible� 24V and 230V manifold loop actuators available� Maximum 15kW output
1059843 to 1059849 - UPONOR COMPACT CONTROL V5 HTG PACKS
Features� Pre-assembled pump unit with 2 to 8 port TM manifolds� Fixed water temperature control pump unit� Acoustic wall mounting brackets� 6m ‘A’ rated pump� Complete with fill and vent points� High limit water temperature thermostat� ¾” Primary isolation and regulation valves� 20 to 65°C secondary water temperature regulation� Left and right hand connection possible� Maximum 15kW output
Features� Pre-assembled �xed water temperature control pump unit� 6m ‘A’ rated pump� TMV with 3.5 kvs and zone actuator with end switch� 1” Primary isolation ball valves� Ideal for direct coupling to a single manifold for multi loop systems� 35 to 60°C secondary water temperature regulation� Supplied for left hand installation, right hand installation possible� Maximum 15kW output
Features� Pre-assembled variable water temperature control pump unit� 6m ‘A’ rated pump� 3 port mixing valve with 6.3 kvs� 1” Primary isolation ball valves� Secondary water temperature immersion pocket� Ideal for direct coupling to a single manifold for multi loop systems� Water temperature control via valve actuator and Uponor controller purchased separately� Supplied for left hand installation, right hand installation possible� Maximum 20kW output� 24V and 230V mixing valve actuators available� Excenter �ttings included for direct manifold coupling, 1059841
Features� Pre-assembled variable water temperature control pump unit� Heating and cooling water temperature control system� Pre-wired mixing valve actuator and weather compensated controller included� Outdoor air sensor provided for site installation� 8m ‘A’ rated pump� 3 port mixing valve with 8 kvs� 1” Primary isolation ball valves� 1½” Secondary connections� Secondary water temperature immersion pocket� Ideal for remote coupling to multiple manifold in a central location� Supplied for left hand installation, right hand installation possible� Maximum 30kW output� Excenter �ttings available for direct manifold coupling