Top Banner
UP TO 43% COST SAVINGS VS. COMPETITIVE BALLASTS Description: Program Start 5-100% dimming, 108-305V, Max. Case Temp 80°C/ Min. Start Temp. 10°C, use with 2 or 1 40 or 28W BX and PL-L Lamps, and 40/32/25/17W T8 Lamps. Approved with GE, Sylvania/Osram, or Philips. Input No. of Lamp Input Input Power Ballast Bench Heat Crest Model # Voltage Lamps Watts Watts Current Factor Factor THD Test at 25ºC Factor (AVG) (MAX) Ambient Temp. AC-S2/40RS-UVS-D 120V 1 28WBX 34.4W 0.29 >0.95 1.1 13.2 48°C <1.7 120V 1 40WBX 37.3W 0.32 >0.95 1.0 12.4 48°C <1.7 277V 1 28WBX 34.0W 0.14 >0.95 1.1 19.0 48°C <1.7 277V 1 40WBX 37.8W 0.15 >0.95 1.0 17.5 48°C <1.7 120V 2 28WBX 68.0W 0.57 >0.95 1.1 7.8 50°C <1.7 120V 2 40WBX 80.0W 0.67 >0.95 1.0 5.4 52°C <1.7 277V 2 28WBX 66.8W 0.25 >0.95 1.1 13.8 45°C <1.7 277V 2 40WBX 79.0W 0.29 >0.95 1.0 11.1 47°C <1.7 120V 1 17WT8 19.8W 0.17 >0.95 1.0 8.8 45°C <1.7 120V 1 25WT8 27.2W 0.23 >0.95 1.0 6.5 45°C <1.7 120V 1 32WT8 34.5W 0.29 >0.95 1.0 4.8 48°C <1.7 120V 1 40WT8 42.1W 0.35 >0.95 1.0 5.4 49°C <1.7 277V 1 17WT8 19.8W 0.78 >0.95 1.0 17.0 43°C <1.7 277V 1 25WT8 27.1W 0.11 >0.95 1.0 14.0 43°C <1.7 277V 1 32WT8 33.9W 0.13 >0.95 1.0 13.0 44°C <1.7 277V 1 40WT8 40.9W 0.15 >0.95 1.0 11.1 44°C <1.7 120V 2 17WT8 39.5W 0.33 >0.95 1.0 8.8 45°C <1.7 120V 2 25WT8 54.4W 0.46 >0.95 1.0 6.5 46°C <1.7 120V 2 32WT8 69.0W 0.58 >0.95 1.0 4.8 47°C <1.7 120V 2 40WT8 84.1W 0.70 >0.95 1.0 5.4 48°C <1.7 277V 2 17WT8 39.5W 0.16 >0.95 1.0 17.0 44°C <1.7 277V 2 25WT8 54.1W 0.21 >0.95 1.0 14.0 46°C <1.7 277V 2 32WT8 67.7W 0.25 >0.95 1.0 13.0 47°C <1.7 277V 2 40WT8 81.8W 0.30 >0.95 1.0 11.1 48°C <1.7 Performance: Voltage Range 108V 305V High Power Factor Rating: Type 1 Outdoor Remote wiring length: 25 ft. Application: Minimum Starting Temperature to -10°C Allowed Maximum Case Temperature 80°C Sound Rating A Rapid Start Safety: UL Listed Type CC HL Certified CUL Certified No PCB’s End of Lamp Life Protection Circuit Auto Reset Carrier Guard™ Protection for Powerline Carrier Signals Surge Protected, Meets ANSI C62.41 EMI/RFI Meets FCC Part 18 Subpart E Class P Thermally Protected (Inherent) Recommend Lamp Burn In of New lamps of 100 hours before dimming Notes: Dimming Range 5-100% Dimming Controls: Use with 0-10V, 1mA, Class 1 & 2 Circuit. Ballast shall ignite the lamps and any setting without first going to a different setting Physical Parameters: Length 9.5” Width 2.78Height 1.5Weight 2.1 lbs Mounting Length 8.75Black, White, Green 12.0Blue, Red 24.0Yellow, Brown 24.0Purple, Gray 12.0” Qty/Carton 10 pcs ©2007
2

UP TO 43% COST SAVINGS VS. COMPETITIVE BALLASTS …ace-ballast.com/...Electronic-Dimming-Ballast-for-Biax-PLL-Lamps.pdf · UP TO 43% COST SAVINGS VS. COMPETITIVE BALLASTS Description:

Feb 04, 2018

Download

Documents

duongkhanh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: UP TO 43% COST SAVINGS VS. COMPETITIVE BALLASTS …ace-ballast.com/...Electronic-Dimming-Ballast-for-Biax-PLL-Lamps.pdf · UP TO 43% COST SAVINGS VS. COMPETITIVE BALLASTS Description:

UP TO 43% COST SAVINGS VS. COMPETITIVE BALLASTS

Description: Program Start 5-100% dimming, 108-305V, Max. Case Temp 80°C/ Min. Start Temp. –10°C, use with 2 or 1 40 or 28W BX and PL-L Lamps, and 40/32/25/17W T8 Lamps. Approved with GE, Sylvania/Osram, or Philips.

Input No. of Lamp Input Input Power Ballast Bench Heat Crest Model # Voltage Lamps Watts Watts Current Factor Factor THD Test at 25ºC Factor

(AVG) (MAX) Ambient Temp. AC-S2/40RS-UVS-D 120V 1 28WBX 34.4W 0.29 >0.95 1.1 13.2 48°C <1.7

120V 1 40WBX 37.3W 0.32 >0.95 1.0 12.4 48°C <1.7 277V 1 28WBX 34.0W 0.14 >0.95 1.1 19.0 48°C <1.7 277V 1 40WBX 37.8W 0.15 >0.95 1.0 17.5 48°C <1.7 120V 2 28WBX 68.0W 0.57 >0.95 1.1 7.8 50°C <1.7 120V 2 40WBX 80.0W 0.67 >0.95 1.0 5.4 52°C <1.7 277V 2 28WBX 66.8W 0.25 >0.95 1.1 13.8 45°C <1.7 277V 2 40WBX 79.0W 0.29 >0.95 1.0 11.1 47°C <1.7 120V 1 17WT8 19.8W 0.17 >0.95 1.0 8.8 45°C <1.7 120V 1 25WT8 27.2W 0.23 >0.95 1.0 6.5 45°C <1.7 120V 1 32WT8 34.5W 0.29 >0.95 1.0 4.8 48°C <1.7 120V 1 40WT8 42.1W 0.35 >0.95 1.0 5.4 49°C <1.7 277V 1 17WT8 19.8W 0.78 >0.95 1.0 17.0 43°C <1.7 277V 1 25WT8 27.1W 0.11 >0.95 1.0 14.0 43°C <1.7 277V 1 32WT8 33.9W 0.13 >0.95 1.0 13.0 44°C <1.7 277V 1 40WT8 40.9W 0.15 >0.95 1.0 11.1 44°C <1.7 120V 2 17WT8 39.5W 0.33 >0.95 1.0 8.8 45°C <1.7 120V 2 25WT8 54.4W 0.46 >0.95 1.0 6.5 46°C <1.7 120V 2 32WT8 69.0W 0.58 >0.95 1.0 4.8 47°C <1.7 120V 2 40WT8 84.1W 0.70 >0.95 1.0 5.4 48°C <1.7 277V 2 17WT8 39.5W 0.16 >0.95 1.0 17.0 44°C <1.7 277V 2 25WT8 54.1W 0.21 >0.95 1.0 14.0 46°C <1.7 277V 2 32WT8 67.7W 0.25 >0.95 1.0 13.0 47°C <1.7 277V 2 40WT8 81.8W 0.30 >0.95 1.0 11.1 48°C <1.7

Performance: • Voltage Range 108V – 305V • High Power Factor • Rating: Type 1 Outdoor • Remote wiring length: 25 ft. Application: • Minimum Starting Temperature to -10°C • Allowed Maximum Case Temperature 80°C • Sound Rating A • Rapid Start Safety: • UL Listed • Type CC • HL Certified • CUL Certified • No PCB’s • End of Lamp Life Protection Circuit • Auto Reset • Carrier Guard™ Protection for Powerline Carrier Signals • Surge Protected, Meets ANSI C62.41 • EMI/RFI Meets FCC Part 18 Subpart E • Class P Thermally Protected (Inherent) • Recommend Lamp Burn In of New lamps of 100 hours before dimming Notes: • Dimming Range 5-100% • Dimming Controls: Use with 0-10V, 1mA, Class 1 & 2 Circuit. • Ballast shall ignite the lamps and any setting without first going to a different setting

Physical Parameters: Length 9.5” Width 2.78” Height 1.5” Weight 2.1 lbs Mounting Length 8.75” Black, White, Green 12.0” Blue, Red 24.0” Yellow, Brown 24.0” Purple, Gray 12.0” Qty/Carton 10 pcs

©2007

Page 2: UP TO 43% COST SAVINGS VS. COMPETITIVE BALLASTS …ace-ballast.com/...Electronic-Dimming-Ballast-for-Biax-PLL-Lamps.pdf · UP TO 43% COST SAVINGS VS. COMPETITIVE BALLASTS Description:

Perfect for Offices, Churches, Convention Areas, Meeting Rooms, etc.Higher Temperature Rating than Competitors for Better Thermal Protection • 80°C Maximum Case Operating Temperature Rating – Up to 13% higher than Competitors • Your Safest Choice For Multi Lamp And Enclosed Fixtures

Costs Up to 43% Less than Competitive Ballasts Maximum Dimming Range for Maximum Flexibility and Energy Savings • 100% to 5% Dimming Output without Annoying Flicker or Humming

Works with any UL Approved 0-10V Lighting Controller

Also Used with 28W, 39W Biax/PL-L Lamps

Innovative Ballast Engineering…with a Payback

1-800-375-6355 Fax: 817-624-8915 • 3401 Avenue D, Arlington, TX 76011 • www.ace-ballast.com

©2007

MAY 2007

Call your AC Representative today at 1-800-375-6355 for additional information or an evaluation sample.

See other side for complete specifications for the 40 Watt Dimming Ballast.

PlusAsk us about our 2 X 80W, T5 and Biax lamp ballast.

2 Lamp X 40 Watt Electronic Dimming Ballast for Biax, PL-L LampsMulti-Voltage - 108 – 305 Volts

AC-S2/40RS-UVS-D

VALU

E PRICED!