Page 1: UNLEASH THE POWER OF REGAL REXNORD

PRODUCT CATALOG

INDUSTRIAL ENDURANCE SERIESTM LARGE MOTORJANUARY 2022 | Europe, Australia, Middle East, North America, Latin America

UNLEASH THE POWEROF REGAL REXNORD

Page 2: UNLEASH THE POWER OF REGAL REXNORD

TABLE OF CONTENTS

NAMEPLATE INFORMATION

page 1

ENDURANCE SERIES page 2

ENDURANCE SERIES NEMA®* MOTORSODP Motor

page 3

page 3

ENDURANCE SERIES IEC®* MOTORS

page 4

LV TEFC Motor

MV TEFC Motor

MV WP1 Motor

MV WP2 Motor

MV TEAAC Motor

page 4

page 5

page 6

page 7

page 8

ENDURANCE SERIES BUILD TO ORDER

page 9

LV ODP Motor

MV ODP Motor

LV WP1 Motor

MV WP1 Motor

LV WP2 Motor

MV WP2 Motor

LV TEFC Motor

MV TEFC Motor

MV TEAAC Motor

page 9

page 10

page 11

page 12

page 13

page 14

page 15

pages 16-17

page 18

BUILD UP OPTIONS / MODIFICATION DESCRIPTION

pages

19-26

v

*NEMA is a trademark or tradename of National Electrical Manufacturers Association and is not owned by or under the control of Regal Rexnord Corporation.

NAMEPLATE INFORMATIONThe nameplate is the key to selecting the proper replacement motor. The model number is the key to finding the correct replacement parts.

Agency symbols

LR2025

ENERGIE VERIFIE

Energy VerifiedOnly

R

SeulementEEV 102077

ENDURANCE SERIES ��

��������������

Inverter information and UL listed Division 2

Connection details for low or high voltage

MODEL - The ID numberCAT.NO. - Catalog numberFRAME - Size and mountingENCL - EnclosurePH - Electrical phaseIP - Ingress protectionIC - Inherent coolingMTG - Conduit box location - F1 or F2DES - Code by NEMA®*CODE - NEMA locked-rotor KVAINSL - Insulation classRISE - Full load operating temperature SF - Percentage of rated HP the motor can safely operate atAMB - The allowable surrounding air temperatureALT - The allowable altitudeVOLTS - Voltage rating of the motor at the operating frequencyHZ - Input frequency of the power supplyHP - Rated horsepower the motor will producekW - Rated output in wattsCos - Cosine is the ratio of actual power to the apparent powerRPM - Full load speed at rated frequencyNOM.EFF. - Average efficiencyFL AMPS - The rated load current expressed in amps at the namplated HP, voltage and frequencyDUTY - Time rating under loadSHAFT END BRG - Drive end bearing sizeOPP END BRG - Opposite drive bearing sizeYOM - Year of ManufactureWt (lbs/kg) - Motor weight in pounds and kilograms

1

Page 3: UNLEASH THE POWER OF REGAL REXNORD

2

ENDURANCE SERIESTM MOTORS

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: NEMA is a trademark or tradename of National Electrical Manufacturers Association;IEC is a trademark of International Electrotechnical Commission.

LARGE, ROBUST MOTORS FOR HEAVY DUTYAND EXTREME APPLICATIONS.

STANDARD FEATURES

• Conduit box is large size and built of cast iron or fabricated steel. IEC®* frame medium voltage motors feature termination connections on standoff insulators (optional on NEMA®* frame motors).

• End turn bracing yields long life and is designed to minimize the effects of coil fatigue from frequent starts, yet it allows for thermal expansion under full load temperatures.

• Corrosion protection against the effects of hostile atmospheres eases hardware removal for regular maintenance inspections. All large motor rotors are epoxy-coated for added protection against chemical attack. The motor nameplate is stainless steel.

• Anti-friction bearings are normally used in applications where high radial or axial thrust loading is common. The bearing chamber and lubrication system are designed with an ample grease supply, safely extending maintenance intervals. Sleeve bearing is optional on IEC frames.

The Marathon® Endurance SeriesTM motors are the right choice for applications demanding ruggedness and high reliability.Users recognize the value of Marathon® motors and their ability to support a multitude of applications with high efficiency and longer performance. Every Marathon Endurance SeriesTM Motor is backed by more than 100 years of manufacturing experience, plus state-of-the-art engineering and production, along with comprehensive service, starting in the earliest planning stages of your motor.

2

Page 4: UNLEASH THE POWER OF REGAL REXNORD

43 43

NE

MA

OD

P M

OT

OR

S

LOW VOLTAGEHP RPM VOLTS FRAME CATALOG

NO. MODEL NO. LIST PRICE (USD)

MULT.SYMBOL

NOM.EFF.

F.L.AMPS

EST. SHIPPING WT. (LBS)

OUTLINEDRAWING

"C" DIM(IN)

FOOTNOTES

500 3600 460 5008S Y9009 5008STDSL16001 $60,559 S6 96.2 551 3980 MCA8247 46.60

600 3600 460 5008S Y9012 5008STDSL16002 $66,260 S6 96.2 636 3420 MCA8247 46.60 8

700 3600 460 5010S Y9015 5010STDSL16001 $76,424 S6 96.2 744 3540 MCA8247 53.60 8

800 3600 460 5808S Y9018 5808STDSL16001 $93,148 S6 95.4 845 5140 MCA8256 53.55 8

900 3600 460 5808S Y9021 5808STDSL16003 $99,319 S6 95.8 950 5250 MCA8256 53.55 8

1000 3600 460 5808S Y9024 5808STDSL16004 $153,028 S6 96.2 1075 5360 MCA8256 53.55 2,3,5

1250 3600 460 5810S Y9027 5810STDSL16001 $160,446 S6 96.2 1337 6270 MCA8256 61.55 2,3,5

ENDURANCE SERIESTM

MOTORSNEMA®* OPEN DRIP PROOF MOTORSGENERAL PURPOSE, NEMA PREMIUM®* EFFICIENCY

APPLICATIONSIndustrial Refrigeration Compressors for HVAC, Oil and Gas, Food and Beverage,Chemical processing, Medical and other process industries.

FEATURES• Meets or exceeds NEMA Premium efficiencies as mandated• Cast Iron frame and brackets, fabricated steel conduit box• Internal epoxy paint• Max Guard® Class F, VPI Insulation system• 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power• Inverter Duty 10:1 Variable• Suitable for Across-the-Line, Wye-Delta and Part-Winding Starting• UL®* Recognized and CSA®* Certified• Ball bearing construction• 120V space heaters - F2 conduit box side• 100Ω Ohm Platinum shielded winding RTD's (2/phase)• Provisions for bearing RTD's - F1 and F2 conduit box side• Three year warranty

IN STOCK MODIFICATION OPTIONS - LIST PRICES (USD)Altitude Rerate Consult Factory

Ambient Rerate Consult FactoryAssembly-F1 to F2 Mounting Conversion $4,604.06Bearing-Current Protection (BCP) $3,161.69

Bearing-Insulated O.D.E. $4,696.37

Bearing-100Ω Platinum $3,277.08

Long Leads-Spliced at Endturn Consult Factory

Nameplate-Auxiliary Tag $1,234.67

Nameplate-Extra Main $1,326.99

Nameplate-Rotation $1,003.89

Packaging-Crate/Export $4,984.85

Rotation-Cast Rotor (CCW --> CW) $1,488.53

Rotation-Copper Bar (CCW --> CW) $6,969.56

Service Factor Consult Factory

WPI Enclosure Modification $8,365.78

WPII Enclosure Modification $31,582.24

MEDIUM VOLTAGEHP RPM VOLTS FRAME CATALOG

NO. MODEL NO. LIST PRICE (USD)

MULT.SYMBOL

NOM.EFF.

F.L.AMPS

EST. SHIPPING WT. (LBS)

OUTLINEDRAWING

"C" DIM(IN)

FOOTNOTES

350 3600 2300/4000 5008S Y9100 5008SVDSL16003 $71,992 S6 94.5 76/44 3310 MCA8250 46.60 2

400 3600 2300/4000 5008S Y9103 5008SVDSL16004 $74,128 S6 95.0 87/50 3390 MCA8250 46.60 2

450 3600 2300/4000 5008S Y9106 5008SVDSL16005 $77,093 S6 95.0 98/56 3570 MCA8250 46.60 2

500 3600 2300/4000 5008S Y9109 5008SVDSL16006 $80,993 S6 95.0 108/62 3630 MCA8250 46.60 2

600 3600 2300/4000 5010S Y9112 5010SVDSL16001 $84,059 S6 95.4 128/74 3780 MCA8250 53.60 2,3,5

700 3600 2300/4000 5010S Y9115 5010SVDSL16002 $88,906 S6 95.4 152/87 3830 MCA8250 53.60 2,3,5

800 3600 2300/4000 5808S Y9118 5808SVDSL16002 $109,245 S6 95.4 175/100 5460 MCA8259 53.55 2,3,5

900 3600 2300/4000 5808S Y9121 5808SVDSL16003 $118,097 S6 95.8 193/111 5510 MCA8259 53.55 2,3,5

1000 3600 2300/4000 5810S Y9124 5810SVDSL16001 $163,680 S6 96.2 216/124 6420 MCA8259 61.55 2,3,5

1250 3600 2300/4000 5810S Y9127 5810SVDSL16002 $170,608 S6 96.2 267/154 6480 MCA8259 61.55 2,3,5

1500 3600 2300/4000 5810S Y9130 5810SVDSL16003 $180,936 S6 96.5 316/182 6810 MCA8259 61.55 2,3,5

1750 3600 2300/4000 5810S Y9133 5810SVDSL16004 $193,601 S6 96.5 369/210 6980 MCA8259 61.55 2,3,5

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: CSA is a trademark or tradename of CSA Group; NEMA and NEMA Premium are trademarks or tradenames of National Electrical Manufacturers Association; UL is a trademark or trade name of Underwriters Laboratories.

Prices and specifications are subject to change without notice.

Catalog number (Cat No.) highlighted bold blue have efficiency levels that meet PREMIUM NEMA MG1 Table 12-12

Footnotes: 1 – Suitable for 2:1 CT operation2 – Form wound coil design 3 – Copper bar rotor design

5 – Fixed CCW rotation, viewing opposite shaft of motor8 – Not defined by NEMA Premium standards

Page 5: UNLEASH THE POWER OF REGAL REXNORD

43

IEC

MO

TO

RS

43

ENDURANCE SERIESTM

MOTORSIEC®* TOTALLY ENCLOSED FAN COOLEDGENERAL PURPOSE IEC

APPLICATIONSIndustrial Refrigeration Compressors for HVAC, Oil and Gas, Food and Beverage, Chemical processing, Medical and other process industries.

FEATURES• Cast iron frame, brackets and conduit box, fabricated steel fan guard• 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power• Provisions to add stub shaft for an encoder• Internal & external epoxy paint• MAX GUARD® Class F, VPI Insulation system• Inverter Duty 10:1 Variable• Extended grease tubes, regreasable in service• Ball bearing construction, insulated NDE bearing• 120V space heaters• 100Ω Ohm Platinum winding RTD's (2/phase)• 100Ω Ohm Platinum bearing RTD's (1/bearing)• Three year warranty

IEC - TEFC - LOW VOLTAGE

HP RPM VOLTS FRAME CATALOGNO. MODEL NO. LIST PRICE

(USD)MULT.

SYMBOLNOM.EFF.

F.L.AMPS

EST. SHIPPING WT. (LBS)

OUTLINEDRAWING

"C" DIM(IN)

FOOTNOTES

4001800 460 355 R9204 355HTFC6027 $77,041 S6 96.2 437 4410 0235501829 60.71 7

1200 460 355 R9205 355HTFC6077 $84,336 S6 95.8 465 4655 0235501829 60.71 7,8

4501800 460 355 R9007 355HTFC6028 $81,265 S6 96.2 492 4720 0235501829 60.71 71200 460 355 R9208 355HTFC6078 $97,024 S6 95.8 524 4890 0235501829 60.71 7,8

5001800 460 355 R9210 355HTFC6029 $85,384 S6 96.2 547 4985 0235501829 60.71 7

1200 460 355X R9211 355HTFC6079 $101,892 S6 95.0 587 6505 0235501810 74.80 8

6001800 460 355X R9212 355HTFC6030 $97,982 S6 95.4 669 6295 0235501810 74.80 8

1200 460 400 R9213 400HTFC6076 $120,018 S6 95.0 688 8670 0240000741 79.72 8

7001800 460 400 R9214 400HTFC6026 $116,347 S6 95.4 772 7540 0240000741 79.72 8

1200 460 400 R9215 400HTFC6077 $163,908 S6 95.0 802 8360 0240000741 79.72 8

8001800 460 400 R9216 400HTFC6027 $139,941 S6 95.4 882 7630 0240000741 79.72 8

1200 460 450 R9217 450HTFC6076 $180,206 S6 95.0 917 11115 0245001030 94.49 8

9001800 460 400 R9218 400HTFC6028 $142,862 S6 95.4 992 7960 0240000741 79.72 8

1200 460 450 R9219 450HTFC6077 $234,103 S6 95.0 1031 11574 0245001030 94.49 8

10001800 460 400 R9220 400HTFC6029 $156,733 S6 95.4 1103 8420 0240000741 79.72 8

1200 460 450 R9221 450HTFC6078 $259,269 S6 95.0 1146 12080 0245001030 94.49 8

IN STOCK MODIFICATION OPTIONS - LIST PRICES (USD)Altitude Rerate Consult Factory

Ambient Rerate Consult FactoryAssembly-F1 to F2 Mounting Conversion $4,604.06Leads-Spliced at Endturn Consult Factory

Nameplate-Auxiliary Tag $1,234.67

Nameplate-Extra Main $1,326.99

Nameplate-Rotation $1,003.89

Packaging-Crate/Export $4,984.85

Rotation-Cast Rotor (CCW --> CW) $1,488.53

Service Factor Consult Factory

Footnotes: 7 – E3 efficiency8 – Not defined by NEMA Premium®* standards

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: NEMA Premium is a trademark or tradename of National Electrical Manufacturers Association; IEC is a trademark of International Electrotechnical Commission and is not owned by or under the control of Regal Rexnord Corporation. Prices and specifications are subject to change without notice.

Catalog number (Cat No.) highlighted bold blue have efficiency levels that meet PREMIUM NEMA MG1 Table 12-12

Consult factory for constant torque speed range.

IEC

TE

FC M

OT

OR

S

Page 6: UNLEASH THE POWER OF REGAL REXNORD

65

IEC

MO

TO

RS

ENDURANCE SERIESTM

MOTORSIEC®* TOTALLY ENCLOSED FAN COOLEDGENERAL PURPOSE IEC

APPLICATIONSChemical plants, pulp and paper mills, refineries, mines, food processing, foundries and other servere duty enviroments where long life and ultra-high effiencies are desired.

FEATURES• Cast iron frame and brackets, fabricated steel conduit box and fan guard• 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power• Form wound coil design, copper bar rotor design• Internal & external epoxy paint• Provisions to add stub shaft for an encoder• MAX GUARD® Class F, VPI Insulation system• Inverter Duty 10:1 Variable• Extended grease tubes, regreasable in service• Brass drain and breather• UL®* Recognized• Ball bearing construction, Insulated NDE bearing• 120V space heaters• 100Ω Ohm Platinum winding RTD's (2/phase)• 100Ω Ohm Platinum bearing RTD's (1/bearing)• Three year warranty

IEC - TEFC - MEDIUM VOLTAGEHP RPM VOLTS FRAME CATALOG

NO. MODEL NO. LIST PRICE (USD)

MULT.SYMBOL

NOM.EFF.

F.L.AMPS

EST. SHIPPING WT. (LBS)

OUTLINEDRAWING

"C" DIM(IN)

FOOTNOTES

3501800 2300/4000 355 R9301 355HVFC6026 $102,057 S6 95.0 78/44.9 4189 0235502685 72.24

1200 2300/4000 355 R9302 355HVFC6077 $118,160 S6 95.0 81.8/47 5622 0235502685 72.24

4001800 2300/4000 355 R9304 355HVFC6027 $108,049 S6 95.0 89.6/51.5 4630 0235502685 72.24

1200 2300/4000 400 R9305 400HVFC6076 $125,830 S6 95.0 91.3/52.5 6614 0240001696 79.13

4501800 2300/4000 355 R9307 355HVFC6028 $120,032 S6 95.0 100/57.5 4740 0235502685 72.24

1200 2300/4000 400 R9308 400HVFC6077 $132,511 S6 95.0 102.6/59 6790 0240001696 79.13

5001800 2300/4000 355 R9310 355HVFC6029 $135,012 S6 95.0 111.3/64 4806 0235502685 72.24

1200 2300/4000 400 R9311 400HVFC6078 $144,689 S6 95.0 113.9/65.5 6945 0240001696 79.13

6001800 2300/4000 400 R9313 400HVFC6026 $145,498 S6 95.4 132.2/76 6460 0240001696 79.13

1200 2300/4000 450 R9314 450HVFC6076 $159,294 S6 95.0 135.7/78 7936 0245001222 87.40

7001800 2300/4000 400 R9316 400HVFC6027 $154,980 S6 95.4 153.9/88.5 6835 0240001696 79.13

1200 2300/4000 450 R9317 450HVFC6077 $180,266 S6 95.0 158.3/91 8488 0245001222 87.40

8001800 2300/4000 450 R9319 450HVFC6026 $166,964 S6 95.4 175.7/101 7826 0245001221 85.83

1200 2300/4000 450 R9320 450HVFC6078 $204,668 S6 95.0 180/103.5 9150 0245001222 87.40

9001800 2300/4000 450 R9322 450HVFC6027 $189,314 S6 95.4 197.4/113.5 8047 0245001221 85.83

1200 4000 500 R9323 500HVFC6076 $250,955 S6 95.0 117 11464 0250000728 94.88

10001800 2300/4000 450 R9325 450HVFC6028 $202,046 S6 95.4 220/126.5 8377 0245001221 85.83

1200 4000 500 R9326 500HVFC6077 $276,466 S6 95.0 130 11905 0250000728 94.88

IN STOCK MODIFICATION OPTIONS - LIST PRICES (USD)Altitude Rerate Consult Factory

Ambient Rerate Consult FactoryAssembly-F1 to F2 Mounting Conversion $4,604.06Leads-Spliced at Endturn Consult Factory

Nameplate-Auxiliary Tag $1,234.67

Nameplate-Extra Main $1,326.99

Nameplate-Rotation $1,003.89

Packaging-Crate/Export $4,984.85

Rotation-Cast Rotor (CCW --> CW) $1,488.53

Service Factor Consult Factory

Prices and specifications are subject to change without notice.

Catalog number (Cat No.) highlighted bold blue have efficiency levels that meet PREMIUM MG1 Table 20-C

Consult factory for constant torque speed range.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: IEC is a trademark of International Electrotechnical Commission; UL is a trademark or trade name of Underwriters Laboratories.

IEC

MV

TE

FC M

OT

OR

S

Page 7: UNLEASH THE POWER OF REGAL REXNORD

65

IEC

MO

TO

RS

ENDURANCE SERIESTM

MOTORSIEC®* WEATHER PROTECTED TYPE 1GENERAL PURPOSE IEC

APPLICATIONSIndustrial Refrigeration Compressors for HVAC, Oil and Gas, Food and Beverage, Chemical processing, Medical and other process industries.

FEATURES• Fabricated steel frame and conduit box, with cast iron brackets• 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power• MAX GUARD®* Class F, VPI Insulation system• Form wound coil design, copper bar rotor design• Internal & external epoxy paint• Inverter Duty 10:1 Variable• Extended grease tubes, regreasable in service• UL®* Recognized• Ball bearing construction, Insulated NDE bearing

IEC - WPI - MEDIUM VOLTAGE

HP RPM VOLTS FRAME CATALOGNO. MODEL NO. LIST PRICE

(USD)MULT.

SYMBOLNOM.EFF.

F.L.AMPS

EST. SHIPPING WT. (LBS)

OUTLINEDRAWING

"C" DIM(IN)

FOOTNOTES

3501800 2300/4000 355 R9401 355HVLF6027 $86,880 S6 91.7 80 / 46 4667 0235502461 72.05 1,4,8

1200 2300/4000 355 R9402 355HVLF6077 $104,708 S6 92.4 83 / 48 4799 0235502461 72.05 8

4001800 2300/4000 355 R9404 355HVLF6028 $91,297 S6 91.7 90 / 52 4667 0235502461 72.05 1,4,8

1200 2300/4000 355 R9405 355HVLF6078 $111,060 S6 92.4 94 / 54 5075 0235502461 72.05 8

4501800 2300/4000 355 R9407 355HVLF6029 $95,258 S6 94.5 101 / 58 4667 0235502461 72.05 1,8

1200 2300/4000 355 R9408 355HVLF6079 $118,040 S6 93.6 104 / 60 5075 0235502461 72.05 8

5001800 2300/4000 355 R9410 355HVLF6030 $99,076 S6 93.0 111 / 64 4667 0235502461 72.05 8

1200 2300/4000 400 R9411 400HVLF6076 $124,886 S6 94.5 117 / 67 6140 0240001510 77.95 1,8

6001800 2300/4000 355 R9413 355HVLF6031 $108,213 S6 93.0 136 / 78 4943 0235502461 72.05 8

1200 2300/4000 400 R9414 400HVLF6077 $131,028 S6 94.5 139 / 80 6448 0240001510 77.95 1,8

7001800 2300/4000 400 R9416 400HVLF6027 $121,806 S6 94.6 160 / 92 6625 0240001510 77.95 1,8

1200 2300/4000 400 R9417 400HVLF6078 $138,473 S6 94.5 162 / 93 6448 0240001510 77.95 8

8001800 2300/4000 400 R9419 400HVLF6028 $128,631 S6 95.0 176 / 101 6625 0240001510 77.95 8

1200 2300/4000 450 R9420 450HVLF6076 $155,970 S6 95.0 181 / 104 7870 0245001121 83.66 1

9001800 2300/4000 400 R9422 400HVLF6029 $138,667 S6 95.0 197 / 113 6867 0240001510 77.95 8

1200 2300/4000 450 R9423 450HVLF6077 $171,368 S6 95.0 203 / 117 7870 0245001121 83.66

10001800 2300/4000 450 R9425 450HVLF6026 $157,402 S6 95.8 216 / 124 8201 0245001121 82.68 1

1200 2300/4000 450 R9426 450HVLF6078 $198,070 S6 95.4 219 / 126 9039 0245001121 83.66

12501800 2300/4000 450 R9428 450HVLF6027 $168,971 S6 95.8 271 / 156 8201 0245001121 82.68

1200 2300/4000 450 R9429 450HVLF6079 $214,614 S6 95.4 278 / 160 9039 0245001121 83.66

15001800 2300/4000 450 R9431 450HVLF6028 $181,959 S6 95.8 325 / 187 8532 0245001121 82.68

1200 4000 500 R9432 500HVLF6076 $236,485 S6 95.8 191 11757 0250000684 89.17 1

1750 1800 4000 500 R9434 500HVLF6026 $202,076 S6 96.2 222 11515 0250000681 89.17

1200 4000 500 R9435 500HVLF6077 $262,804 S6 95.4 224 11757 0250000684 89.17

20001800 4000 500 R9437 500HVLF6027 $219,004 S6 96.2 253 11515 0250000681 89.17

1200 4000 560 R9438 560HVLF6076 $287,565 S6 95.4 250 15068 0256000375 100.79 1

22501800 4000 500 R9440 500HVLF6028 $246,267 S6 96.2 279 12617 0250000681 89.17

1200 4000 560 R9441 560HVLF6077 $311,234 S6 96.5 285 15642 0256000375 100.79

2500 1800 4000 560 R9443 560HVLF6026 $290,330 S6 96.5 306 16391 0256000372 98.82 1

3000 1800 4000 560 R9446 560HVLF6027 $308,582 S6 96.5 363 16391 0256000372 98.82 1,8

3500 1800 4000 560 R9449 560HVLF6028 $339,440 S6 96.7 433 16391 0256000372 98.82 8

• 120V space heaters• 100Ω Ohm Platinum

winding RTD's (2/phase)• 100Ω Ohm Platinum

bearing RTD's (1/bearing)• Three year warranty

Footnotes: 1 - Suitable for 2:1 CT operation

4 - 1.2 Service Factor8 - Not defined by NEMA

Premium standards

Prices and specifications are subject to change without notice.

Catalog number (Cat No.) highlighted bold blue have efficiency levels that meet PREMIUM MG1 Table 20-C

Consult factory for constant torque speed range.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: IEC is a trademark of International Electrotechnical Commission; UL is a trademark or trade name of Underwriters Laboratories.

IN STOCK MODIFICATION OPTIONS - LIST PRICES (USD)Altitude Rerate Consult FactoryAmbient Rerate Consult FactoryAssembly-F1 to F2 Mounting Conversion $4,604.06Leads-Spliced at Endturn Consult FactoryNameplate-Auxiliary Tag $1,234.67

Nameplate-Extra Main $1,326.99Nameplate-Rotation $1,003.89Packaging-Crate/Export $4,984.85Rotation-Cast Rotor (CCW --> CW) $1,488.53Service Factor Consult Factory

IEC

MV

WP

I MO

TO

RS

Page 8: UNLEASH THE POWER OF REGAL REXNORD

87

IEC

MO

TO

RS

Footnotes: 1 - Suitable for 2:1 CT operation

4 - 1.2 Service Factor8 - Not defined by NEMA Premium standards

ENDURANCE SERIESTM

MOTORSIEC®* WEATHER PROTECTED TYPE 2GENERAL PURPOSE IEC

APPLICATIONSIndustrial Refrigeration Compressors for HVAC, Oil and Gas, Food and Beverage, Chemical processing, Medical and other process industries.

FEATURES• Fabricated steel frame and conduit box, with cast iron brackets• 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power• MAX GUARD® Class F, VPI Insulation system• Form wound coil design, copper bar rotor design• Internal & external epoxy paint• Inverter Duty 10:1 Variable• Extended grease tubes, regreasable in service• UL®* Recognized• Ball bearing construction, Insulated NDE bearing

IEC - WPII - MEDIUM VOLTAGE

HP RPM VOLTS FRAME CATALOGNO. MODEL NO. LIST PRICE

(USD)MULT.

SYMBOLNOM.EFF.

F.L.AMPS

EST. SHIPPING WT. (LBS)

OUTLINEDRAWING

"C" DIM(IN)

FOOTNOTES

3501800 2300/4000 355 R9501 355HVMF6027 $104,568 S6 91.7 80 / 46 5072 0235502462 74.21 1,4,81200 2300/4000 355 R9502 355HVMF6078 $115,718 S6 92.4 83 / 48 5182 0235502462 74.21 8

4001800 2300/4000 355 R9504 355HVMF6028 $107,763 S6 91.7 90 / 52 5072 0235502462 74.21 1,81200 2300/4000 355 R9505 355HVMF6079 $122,339 S6 92.4 94 / 54 5479 0235502462 74.21 8

4501800 2300/4000 355 R9507 355HVMF6029 $112,028 S6 94.5 101 / 58 5072 0235502462 74.21 1,81200 2300/4000 355 R9508 355HVMF6080 $129,200 S6 93.6 104 / 60 5479 0235502462 74.21 8

5001800 2300/4000 355 R9510 355HVMF6030 $115,344 S6 93.0 111 / 64 5347 0235502462 74.21 81200 2300/4000 400 R9511 400HVMF6076 $136,256 S6 94.5 117 / 67 6526 0240001511 78.54 1,8

6001800 2300/4000 355 R9513 355HVMF6031 $131,073 S6 93.0 136 / 78 5347 0235502462 74.21 81200 2300/4000 400 R9514 400HVMF6077 $148,614 S6 94.5 139 / 80 6834 0240001511 78.54 1,8

7001800 2300/4000 400 R9516 400HVMF6026 $142,034 S6 94.6 160 / 92 7011 0240001511 78.54 1,81200 2300/4000 400 R9517 400HVMF6078 $166,649 S6 94.5 162 / 93 6834 0240001511 78.54 8

8001800 2300/4000 400 R9519 400HVMF6027 $149,123 S6 95.0 176 / 101 7011 0240001511 78.54 81200 2300/4000 450 R9520 450HVMF6076 $187,606 S6 95.0 181 / 104 8467 0245001125 84.84 1

9001800 2300/4000 400 R9522 400HVMF6028 $163,279 S6 95.0 197 / 113 7253 0240001511 78.54 81200 2300/4000 450 R9523 450HVMF6077 $212,158 S6 95.0 203 / 117 8467 0245001125 84.84

10001800 2300/4000 450 R9525 450HVMF6026 $182,656 S6 95.8 216 / 124 8710 0245001122 83.271200 2300/4000 450 R9526 450HVMF6078 $232,478 S6 95.4 219 / 126 9636 0245001125 84.84

12501800 2300/4000 450 R9528 450HVMF6027 $198,421 S6 95.8 271 / 156 8710 0245001122 83.271200 2300/4000 450 R9529 450HVMF6079 $258,101 S6 95.4 278 / 160 9636 0245001125 84.84

15001800 2300/4000 450 R9531 450HVMF6028 $220,576 S6 95.8 325 / 187 9129 0245001122 83.271200 4000 500 R9532 500HVMF6076 $283,057 S6 95.8 184 12368 0250000685 90.94 1

17501800 4000 500 R9534 500HVMF6026 $245,927 S6 96.2 222 12125 0250000682 90.941200 4000 500 R9535 500HVMF6077 $305,721 S6 95.4 224 12368 0250000685 90.94

20001800 4000 500 R9537 500HVMF6027 $261,591 S6 96.2 253 12125 0250000682 90.941200 4000 560 R9538 560HVMF6076 $335,344 S6 95.4 253 15741 0256000376 103.74 1

22501800 4000 500 R9540 500HVMF6028 $290,112 S6 96.2 279 13228 0250000682 90.941200 4000 560 R9541 560HVMF6077 $364,142 S6 96.5 285 16314 0256000376 103.74

25001800 4000 560 R9543 560HVMF6026 $302,302 S6 96.5 306 17064 0256000373 101.77 11200 4000 560 R9544 560HVMF6078 $364,142 S6 96.5 285 16314 0256000376 103.74

3000 1800 4000 560 R9546 560HVMF6027 $315,024 S6 96.5 363 17064 0256000373 101.77 1,83500 1800 4000 560 R9549 560HVMF6028 $333,558 S6 96.5 433 17064 0256000373 101.77 8

• 120V space heaters• 100Ω Ohm Platinum winding RTD's (2/phase)• 100Ω Ohm Platinum bearing RTD's (1/bearing)• Three year warranty

Catalog number (Cat No.) highlighted bold blue have efficiency levels that meet PREMIUM MG1 Table 20-C

IN STOCK MODIFICATION OPTIONS - LIST PRICES (USD)Altitude Rerate Consult FactoryAmbient Rerate Consult FactoryAssembly-F1 to F2 Mounting Conversion $4,604.06

Leads-Spliced at Endturn Consult FactoryNameplate-Auxiliary Tag $1,234.67

Nameplate-Extra Main $1,326.99Nameplate-Rotation $1,003.89Packaging-Crate/Export $4,984.85Rotation-Cast Rotor(CCW --> CW) $1,488.53

Service Factor Consult Factory

Consult factory for constant torque speed range.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: IEC is a trademark of International Electrotechnical Commission; UL is a trademark or trade name of Underwriters Laboratories.

IEC

MV

WP

II MO

TO

RS

Page 9: UNLEASH THE POWER OF REGAL REXNORD

87

IEC

MO

TO

RS

ENDURANCE SERIESTM

MOTORSIEC®* TOTALLY ENCLOSED AIR-TO-AIR COOLEDGENERAL PURPOSE IEC

APPLICATIONSIndustrial Refrigeration Compressors for HVAC, Oil and Gas, Food and Beverage, Chemical processing, Medical and other process industries.

FEATURES• Fabricated steel frame and conduit box, with cast iron brackets• 1.15 Service Factor on sinewave, 1.0 Service Factor on IGBT power• MAX GUARD® Class F, VPI Insulation system• Form wound coil design, copper bar rotor design• Internal & external epoxy paint• Inverter Duty 10:1 Variable• Extended grease tubes, regreasable in service• UL®* Recognized• Ball bearing construction, Insulated NDE bearing• 120V space heaters• 100Ω Ohm Platinum winding RTD's (2/phase)• 100Ω Ohm Platinum bearing RTD's (1/bearing)• Three year warranty

IEC - TEAAC - MEDIUM VOLTAGE

HP RPM VOLTS FRAME CATALOGNO. MODEL NO. LIST PRICE

(USD)MULT.

SYMBOLNOM.EFF.

F.L.AMPS

EST. SHIPPING WT. (LBS)

OUTLINEDRAWING

"C" DIM(IN)

FOOTNOTES

3501800 2300/4000 355 R9601 355HVKF6027 $137,990 S6 93.0 80 / 46 5203 0235502463 83.07 1,8

1200 2300/4000 355 R9602 355HVKF6077 $156,549 S6 92.4 83 / 48 5611 0235502463 83.07 8

4001800 2300/4000 355 R9604 355HVKF6028 $137,990 S6 93.6 90 / 52 5203 0235502463 83.07 1,8

1200 2300/4000 400 R9605 400HVKF6076 $156,549 S6 94.1 94 / 54 6845 0240001512 87.99 1,8

4501800 2300/4000 355 R9607 355HVKF6029 $145,291 S6 93.0 103 / 59 5478 0235502463 83.07 8

1200 2300/4000 400 R9608 400HVKF6077 $164,157 S6 94.1 104 / 60 6845 0240001512 87.99 1,8

5001800 2300/4000 355 R9610 355HVKF6030 $152,051 S6 93.0 117 / 67 5478 0235502463 83.07 8

1200 2300/4000 400 R9611 400HVKF6078 $172,378 S6 94.1 117 / 67 7154 0240001512 87.99 1,8

6001800 2300/4000 400 R9613 400HVKF6026 $160,258 S6 94.1 136 / 78 7330 0240001512 87.99 1,8

1200 2300/4000 400 R9614 400HVKF6079 $180,409 S6 94.1 141 / 81 7154 0240001512 87.99 8

7001800 2300/4000 400 R9616 400HVKF6027 $168,231 S6 94.5 155 / 89 7330 0240001512 87.99 8

1200 2300/4000 450 R9617 450HVKF6076 $189,170 S6 93.6 158 / 91 8918 0245001126 95.67 8

8001800 2300/4000 400 R9619 400HVKF6028 $177,605 S6 94.5 176 / 101 7573 0240001512 87.99 8

1200 2300/4000 450 R9620 450HVKF6077 $198,413 S6 94.1 183 / 105 8918 0245001126 95.67 8

9001800 2300/4000 450 R9622 450HVKF6026 $188,673 S6 94.5 197 / 113 9215 0245001123 94.09 8

1200 2300/4000 450 R9623 450HVKF6078 $215,950 S6 94.5 200 / 115 10086 0245001126 95.67 8

10001800 2300/4000 450 R9625 450HVKF6027 $201,144 S6 94.5 219 / 126 9215 0245001123 94.09 8

1200 2300/4000 450 R9626 450HVKF6079 $221,046 S6 94.5 221 / 127 10086 0245001126 95.67 8

12501800 2300/4000 450 R9628 450HVKF6028 $214,359 S6 95.0 273 / 157 9546 0245001123 94.09 8

1200 4000 500 R9629 500HVKF6076 $244,544 S6 95.0 161 13635 0250000686 101.38

15001800 4000 500 R9631 500HVKF6026 $227,427 S6 95.4 192 13360 0250000683 101.38

1200 4000 500 R9632 500HVKF6077 $266,926 S6 95.0 193 13635 0250000686 101.38

17501800 4000 500 R9634 500HVKF6027 $243,256 S6 95.4 224 13360 0250000683 101.38 8

1200 4000 560 R9635 560HVKF6076 $302,511 S6 95.0 221 17769 0256000377 113.58 1,8

IN STOCK MODIFICATION OPTIONS - LIST PRICES (USD)Altitude Rerate Consult FactoryAmbient Rerate Consult FactoryAssembly-F1 to F2Mounting Conversion $4,604.06

Leads-Spliced at Endturn Consult FactoryNameplate-Auxiliary Tag $1,234.67

Nameplate-Extra Main $1,326.99Nameplate-Rotation $1,003.89Packaging-Crate/Export $4,984.85Rotation-Cast Rotor(CCW --> CW) $1,488.53

Service Factor Consult Factory

Footnotes: 1 - Suitable for 2:1 CT operation

8 - Not defined by NEMA Premium standards

Prices and specifications are subject to change without notice.

Catalog number (Cat No.) highlighted bold blue have efficiency levels that meet PREMIUM MG1 Table 20-C

Consult factory for constant torque speed range.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: IEC is a trademark of International Electrotechnical Commission; UL is a trademark or trade name of Underwriters Laboratories.

IEC

MV

TE

AA

C M

OT

OR

SB

TO

TE

FC M

OT

OR

S

Page 10: UNLEASH THE POWER OF REGAL REXNORD

109

ENDURANCE SERIESTM

MOTORSOPEN DRIP PROOFLOW VOLTAGE

BUILT TO ORDER FEATURES• Rigid, Horizontal Mounting• Cast iron frame & brackets (NEMA®*)• MAXGUARD® Class F insulation system• IP23 minimum• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

Consult factory for 449 frame & smaller Consult factory for 315 frame & smaller

ODP - LOW VOLTAGE

HP RPMNEMA FRAME DESIGNS IEC FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES FRAME LIST PRICE (USD) FOOTNOTES

350

3600 - - - -

1800 505 $69,652 - -

1200 508 $86,464 - -

400

3600 - - - -

1800 508 $91,850 - -

1200 508 #VALUE! - -

450

3600 - - - -

1800 508 $94,347 - -

1200 - - - -

500

3600 5008S $73,903 - -

1800 508 $93,949 - -

1200 - - 355 $93,730

600

3600 5008S $82,969 - -

1800 510 $122,068 355 $76,995

1200 - - 355 $96,502

700

3600 5010S $92,479 - -

1800 5808 $147,355 355 $88,200

1200 - - 355 $114,858

800

3600 5808S $116,638 - -

1800 5808 $155,656 355 $75,802

1200 - - - -

900

3600 5808S $122,240 - -

1800 5810 $179,735 355 $112,460

1200 - - - -

1000

3600 5810S $188,343 2,3 - -

1800 5810 $193,079 - -

1200 - - - -

1250

3600 5810S $195,799 2,3 - -

1800 - - - -

1200 - - - -

1500

3600 - - - -

1800 - - - -

1200 - - - -

1750

3600 - - - -

1800 - - - -

1200 - - - -

2000

3600 - - - -

1800 - - - -

1200 - - - -

Footnotes: 1 - Suitable for 2:1 CT operation2 - Form wound coil design3 - Copper bar rotor design4 - 1.2 Service Factor5 - Fixed CCW rotation, viewing

opposite shaft of motor6 - Sleeve Bearing7 - Includes 100Ω Platinum

Winding RTD's & Bearing RTD's

*NEMA is a trademark or tradename of National Electrical Manufacturers Association and is not owned by or under the control of Regal Rexnord Corporation.

BT

O O

DP

MO

TO

RS

Page 11: UNLEASH THE POWER OF REGAL REXNORD

109

Footnotes: 2 - Form wound coil design3 - Copper bar rotor design6 - Sleeve Bearing

ENDURANCE SERIESTM

MOTORSOPEN DRIP PROOFMEDIUM VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting• Cast iron frame & brackets (NEMA®*)• Fabricated frame & cast iron brackets (IEC®*)• MAXGUARD® Class F insulation system• IP23 minimum• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

ODP - MEDIUM VOLTAGE

HP RPMNEMA FRAME DESIGNS IEC FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES FRAME LIST PRICE (USD) FOOTNOTES

350

3600 5008S $73,212 2 Consult Factory

1800 - - 355 $74,642 2,3

1200 - - 355 $77,560 2,3

400

3600 5008S $75,384 2 Consult Factory

1800 - - 355 $75,760 2,3

1200 - - 400 $80,460 2,3

450

3600 5008S $78,399 2 Consult Factory

1800 - - 400 $77,560 2,3

1200 - - 400 $91,654 2,3

500

3600 5008S $82,366 2 Consult Factory

1800 - - 400 $78,722 2,3

1200 - - 400 $97,192 2,3

600

3600 5010S $84,765 2,3 Consult Factory

1800 - - 400 $80,460 2,3

1200 - - 450 $99,955 2,3

700

3600 5808S $88,171 2,3 Consult Factory

1800 - - 400 $94,204 2,3

1200 - - 450 $123,852 2,3

800

3600 5808S $113,013 2,3 Consult Factory

1800 - - 450 $99,955 2,3

1200 - - 450 $131,731 2,3

900

3600 5808S $124,313 2,3 Consult Factory

1800 - - 450 $101,452 2,3

1200 - - 450 $149,426 2,3

1000

3600 5810S $169,324 2,3 Consult Factory

1800 - - 450 $126,435 2,3

1200 - - 500 $179,762 2,3

1250

3600 5810S $181,177 2,3 Consult Factory

1800 - - 450 $149,426 2,3

1200 - - 500 $203,428 2,3

1500

3600 5810S $193,860 2,3 Consult Factory

1800 - - 500 $153,497 2,3

1200 - - 560 $220,067 2,3

1750

3600 5810S $207,430 2,3 Consult Factory

1800 - - 500 $182,926 2,3

1200 - - 560 $296,577 2,3

2000

3600 - - Consult Factory

1800 - - 560 $219,515 2,3

1200 - - 630 $339,644 2,3,6

Consult factory for 449 frame & smaller Consult factory for 315 frame & smaller

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: IEC is a trademark of International Electrotechnical Commission; NEMA is a trademark or tradename of National Electrical Manufacturers Association. 

BT

O M

V O

DP

MO

TO

RS

Page 12: UNLEASH THE POWER OF REGAL REXNORD

1211

Footnotes: 2 - Form wound coil design3 - Copper bar rotor design

ENDURANCE SERIESTM

MOTORSWEATHER PROTECTED TYPE 1LOW VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting • Cast iron frame & brackets (NEMA®*) • MAXGUARD® Class F insulation system • 120V or 240V space heaters • Stator/Rotor Epoxy • IP23 minimum• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

WPI - LOW VOLTAGE

HP RPMNEMA FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES

350

3600 - -

1800 505 $73,398

1200 508 $90,211

400

3600 - -

1800 508 $95,596

1200 508 $98,093

450

3600 - -

1800 508 $98,093

1200 - -

500

3600 5008S $66,721

1800 508 $97,695

1200 - -

600

3600 5008S $74,277

1800 510 $125,815

1200 - -

700

3600 5010S $82,202

1800 5808 $151,101

1200 - -

800

3600 5808S $102,334

1800 5808 $159,402

1200 - -

900

3600 5808S $107,043

1800 5810 $183,481

1200 - -

1000

3600 5810S $162,088 2,3

1800 5810 $196,825

1200 - -

1250

3600 5810S $168,302 2,3

1800 - -

1200 - -

1500

3600 - -

1800 - -

1200 - -

1750

3600

1800 - -

1200 - -

2000

3600 - -

1800 - -

1200 - -

Consult factory for 449 frame & smaller

BT

O W

PI M

OT

OR

S

Page 13: UNLEASH THE POWER OF REGAL REXNORD

1211

ENDURANCE SERIESTM

MOTORSWEATHER PROTECTED TYPE 1MEDIUM VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting• Fabricated frame & cast iron brackets (IEC®*) • Cast iron frame & brackets (NEMA®*) • MAXGUARD® Class F insulation system • 120V or 240V space heaters • Stator/Rotor Epoxy

WPI - MEDIUM VOLTAGE

HP RPMNEMA FRAME DESIGNS IEC FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES FRAME LIST PRICE (USD) FOOTNOTES

350

3600 5008S $78,348 2 Consult Factory

1800 - - 355 $71,793 2,3,7

1200 - - 355 $87,990 2,3,7

400

3600 5008S $80,520 2 Consult Factory

1800 - - 355 $75,444 2,3,7

1200 - - 355 $93,319 2,3,7

450

3600 5008S $83,535 2 Consult Factory

1800 - - 355 $78,717 2,3,7

1200 - - 355 $99,193 2,3,7

500

3600 5008S $87,502 2 Consult Factory

1800 - - 355 $99,898 2,3,7

1200 - - 400 $125,930 2,3,7

600

3600 5010S $89,901 2,3 Consult Factory

1800 - - 355 $109,113 2,3,7

1200 - - 400 $132,124 2,3,7

700

3600 5808S $93,307 2,3 Consult Factory

1800 - - 400 $120,794 2,3,7

1200 - - 400 $139,626 2,3,7

800

3600 5808S $118,148 2,3 Consult Factory

1800 - - 400 $129,707 2,3,7

1200 - - 450 $154,681 2,3,7

900

3600 5808S $129,449 2,3 Consult Factory

1800 - - 400 $139,828 2,3,7

1200 - - 450 $172,808 2,3,7

1000

3600 5810S $174,460 2,3 Consult Factory

1800 - - 450 $156,092 2,3,7

1200 - - 450 $196,423 2,3,7

1250

3600 5810S $186,312 2,3 Consult Factory

1800 - - 450 $170,391 2,3,7

1200 - - 450 $216,413 2,3,7

1500

3600 5810S $198,996 2,3 Consult Factory

1800 - - 450 $183,483 2,3,7

1200 - - 500 $238,467 2,3,7

1750

3600 5810S $212,566 2,3 Consult Factory

1800 - - 500 $200,401 2,3,7

1200 - - 500 $265,003 2,3,7

2000

3600 - - Consult Factory

1800 - - 500 $220,844 2,3,7

1200 - - 560 $287,560 2,3,7

Consult factory for 449 frame & smaller

Footnotes:2 - Form wound coil design3 - Copper bar rotor design7 - Includes 100Ω Platinum Winding

RTD's & Bearing RTD'sConsult factory for 315 frame & smaller

• IP23 minimum• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: IEC is a trademark of International Electrotechnical Commission; NEMA is a trademark or tradename of National Electrical Manufacturers Association. 

BT

O W

PII

MO

TO

RS

Page 14: UNLEASH THE POWER OF REGAL REXNORD

1413

ENDURANCE SERIESTM

MOTORSWEATHER PROTECTED TYPE 2LOW VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting• Cast iron frame & brackets (NEMA®*)• MAXGUARD® Class F insulation system• 120V or 240V space heaters• Stator/Rotor Epoxy• IP24 minimum

WPII - LOW VOLTAGE

HP RPMNEMA FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES

350

3600 - -

1800 - -

1200 - -

400

3600 - -

1800 - -

1200 - -

450

3600 - -

1800 - -

1200 - -

500

3600 5008S $95,573

1800 - -

1200 - -

600

3600 5010S $103,128

1800 - -

1200 - -

700

3600 5808S $111,054

1800 - -

1200 - -

800

3600 5808S $131,186

1800 - -

1200 - -

900

3600 5808S $135,853

1800 - -

1200 - -

1000

3600 5810S $190,940 2,3

1800 - -

1200 - -

1250

3600 5810S $197,153 2,3

1800 - -

1200 - -

1500

3600 - -

1800 - -

1200 - -

1750

3600 - -

1800 - -

1200 - -

2000

3600 - -

1800 - -

1200 - -

Consult factory for 449 frame & smaller

Footnotes: 2 - Form wound coil design3 - Copper bar rotor design6 - Sleeve Bearing

*NEMA is a trademark or tradename of National Electrical Manufacturers Association and is not owned by or under the control of Regal Rexnord Corporation.

• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

BT

O M

V W

PI M

OT

OR

S

Page 15: UNLEASH THE POWER OF REGAL REXNORD

1413

ENDURANCE SERIESTM

MOTORSWEATHER PROTECTED TYPE 2MEDIUM VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting • Cast iron frame & brackets (NEMA®*) • Fabricated frame & cast iron brackets (IEC®*) • MAXGUARD® Class F insulation system • 120V or 240V space heaters • IP24 minimum• 60 Hertz• 40°C Ambient

WPII - MEDIUM VOLTAGE

HP RPMNEMA FRAME DESIGNS IEC FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES FRAME LIST PRICE (USD) FOOTNOTES

350

3600 5008S $107,199 2 Consult Factory

1800 - - 355 $102,844 2,3,7

1200 - - 355 $116,691 2,3,7

400

3600 5008S $109,372 2 Consult Factory

1800 - - 355 $106,872 2,3,7

1200 - - 355 $123,362 2,3,7

450

3600 5008S $112,387 2 Consult Factory

1800 - - 355 $111,088 2,3,7

1200 - - 355 $130,286 2,3,7

500

3600 5008S $116,353 2 Consult Factory

1800 - - 355 $116,313 2,3,7

1200 - - 400 $137,398 2,3,7

600

3600 5010S $118,753 2,3 Consult Factory

1800 - - 355 $132,174 2,3,7

1200 - - 400 $149,860 2,3,7

700

3600 5808S $122,159 2,3 Consult Factory

1800 - - 400 $140,860 2,3,7

1200 - - 400 $168,050 2,3,7

800

3600 5808S $147,000 2,3 Consult Factory

1800 - - 400 $150,364 2,3,7

1200 - - 450 $186,051 2,3,7

900

3600 5808S $158,300 2,3 Consult Factory

1800 - - 400 $164,651 2,3,7

1200 - - 450 $213,933 2,3,7

1000

3600 5810S $203,311 2,3 Consult Factory

1800 - - 450 $181,141 2,3,7

1200 - - 450 $230,549 2,3,7

1250

3600 5810S $215,164 2,3 Consult Factory

1800 - - 450 $200,086 2,3,7

1200 - - 450 $260,257 2,3,7

1500

3600 5810S $227,848 2,3 Consult Factory

1800 - - 450 $222,430 2,3,7

1200 - - 500 $285,433 2,3,7

1750

3600 5810S $241,418 2,3 Consult Factory

1800 - - 500 $243,893 2,3,7

1200 - - 500 $308,280 2,3,7

2000

3600 - - Consult Factory

1800 - - 500 $263,782 2,3,7

1200 - - 560 $335,344 2,3,7

Consult factory for 449 frame & smaller

Footnotes: 2 - Form wound coil design3 - Copper bar rotor design7 - Includes 100Ω Platinum Winding

RTD's & Bearing RTD's

Consult factory for 315 frame & smaller

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: IEC is a trademark of International Electrotechnical Commission; NEMA is a trademark or tradename of National Electrical Manufacturers Association. 

• 3300 FSL max• Stator/Rotor Epoxy• Three year warranty

BT

O T

EFC

MO

TO

RS

Page 16: UNLEASH THE POWER OF REGAL REXNORD

1615*NEMA is a trademark or tradename of National Electrical Manufacturers Association and is not owned by or under the control of Regal Rexnord Corporation.

ENDURANCE SERIESTM

MOTORSTOTALLY ENCLOSED FAN COOLEDLOW VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting • Cast iron frame and brackets • MAXGUARD® Class F insulation system • NEMA®* Design B • IP54 minimum• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

TEFC - LOW VOLTAGE

HP RPMNEMA FRAME DESIGNS IEC FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES FRAME LIST PRICE (USD) FOOTNOTES

400

3600 5011 $115,283 355 $85,394

1800 5011 $112,640 355 $83,437

1200 5011 $131,905 355 $97,708

900 5013 $190,748 400 $119,218

450

3600 5011 $117,635 355 $87,137

1800 5011 $116,262 355 $86,120

1200 5013 $178,928 400 $119,286

900 - - 400 $141,952

500

3600 5011 $131,197 355 $97,183

1800 5011 $118,001 355 $87,409

1200 5013 $214,593 400 $119,218

900 - - 400 $195,313

600

3600 - - 400 $103,339

1800 5011 $123,571 400 $91,534

1200 - - 400 $141,952

900 - - 400 $212,868

700

3600 - - 400 $127,701

1800 5013 $202,786 400 $119,286

1200 - - 400 $201,171

900 - - 450 $220,977

800

3600 - - 400 $153,241

1800 - - 400 $149,107

1200 - - 450 $215,977

900 - - 500 $293,716

900

3600 - - 400 $183,889

1800 - - 400 $201,295

1200 - - 450 $248,374

900 - -   500 $323,087

1000

3600 - - 400 $205,956

1800 - - 400 $221,424

1200 - - 450 $273,211

900 - - 560 $403,860

1250

3600 - - 450 $247,148

1800 - - 450 $276,781

1200 - - 500 $341,514

900 - - 560 $444,246

1500

3600 - - 500 $308,935

1800 - - 500 $359,814

1200 - - 500 $375,665

17501800 - - 500 $402,992

1200 - - 560 $469,581

20001800 - - 560 $523,890

1200 - - 560 $525,930

Consult factory for 449 frame & smaller

Footnotes: 1 - Suitable for 2:1 CT operation2 - Form wound coil design3 - Copper bar rotor design4 - 1.2 Service Factor5 - Fixed CCW rotation, viewing

opposite shaft of motor6 - Sleeve Bearing7 - Includes 100Ω PlatinumWinding

RTD's & Bearing RTD's

Consult factory for 315 frame & smaller

BT

O M

V W

PII M

OT

OR

S

Page 17: UNLEASH THE POWER OF REGAL REXNORD

1615*NEMA is a trademark or tradename of National Electrical Manufacturers Association and is not owned by or under the control of Regal Rexnord Corporation.

ENDURANCE SERIESTM

MOTORSTOTALLY ENCLOSED FAN COOLEDMEDIUM VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting• Cast iron frame and brackets• MAXGUARD® Class F insulation system• NEMA®* Design B• IP54 minimum• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

TEFC - MEDIUM VOLTAGE

HP RPMNEMA FRAME DESIGNS IEC FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES FRAME LIST PRICE (USD) FOOTNOTES150 900 5011 $130,554 355 $85,102 2,3 

200

3600 - - 355 $82,552 2,3

1800 5011 $114,294 355 $76,196 2,3 

1200 5011 $120,237 355 $80,158 2,3

900 5011 $141,907 355 $92,502 2,3 

250

3600 5009 $121,137 355 $89,731 2,3

1800 5011 $111,809 355 $82,821 2,3 

1200 5011 $130,692 355 $87,129 2,3

900 5011 $159,813 400 $113,646 2,3 

300

3600 5011 $136,658 355 $89,081 2,3

1800 5011 $131,876 355 $85,963 2,3 

1200 5011 $138,739 400 $98,658 2,3

900 5013 $201,295 400 $143,143 2,3 

350

3600 5011 $141,858 355 $92,470 2,3

1800 5011 $133,964 355 $87,324 2,3 

1200 5011 $159,813 400 $113,646 2,3

900 5013 $214,798 450 $165,473 2,3 

400

3600 5011 $144,104 400 $102,474 2,3

1800 5011 $140,801 400 $100,125 2,3 

1200 5011 $164,881 400 $117,250 2,3

900 5013 $209,823 450 $143,061 2,3 

450

3600 5011 $129,398 400 $104,563 2,3

1800 5011 $145,327 400 $103,344 2,3 

1200 5013 $196,822 450 $143,143 2,3

900 - - 450 $170,342 2,3 

500

3600 - - 400 $116,620 2,3

1800 5013 $177,002 400 $104,891 2,3 

1200 5013 $236,051 450 $143,061 2,3

900 - - 450 $234,375 2,3 

600

3600 - - 400 $113,673 2,3

1800 5011 $154,464 450 $109,840 2,3 

1200 - - 450 $170,342 2,3

900 - - 450 $255,442 2,3 

700

3600 - - 450 $153,241 2,3

1800 5013 $223,064 450 $143,143 2,3 

1200 - - 450 $241,406 2,3

900 - - 500 $265,173 2,3 

800

3600 - - 450 $183,889 2,3

1800 5013 $241,554 450 $178,928 2,3 

1200 - - 500 $259,172 2,3 

900 - - 500 $323,087 2,3

Consult factory for 449 frame & smaller

Footnotes:2 - Form wound coil design3 - Copper bar rotor design

Consult factory for 315 frame & smaller Continue on page 20

BT

O M

V T

EFC

MO

TO

RS

Page 18: UNLEASH THE POWER OF REGAL REXNORD

1817

TEFC - MEDIUM VOLTAGE

HP RPMNEMA FRAME DESIGNS IEC FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES FRAME LIST PRICE (USD) FOOTNOTES

900

3600 - - 450 $220,668 1800 - - 450 $241,554 1200 - - 500 $298,049 900 - - 500 $355,397

1000

3600 - - 500 $267,743 1800 - - 500 $287,852 1200 - - 500 $327,853 900 - - 560 $444,246

1250

3600 - - 500 $296,577 1800 - - 500 $332,137 1200 - - 560 $409,816 900 - - 560 $488,670

1500

3600 - - 500 $339,828 1800 - - 500 $395,796 1200 - - 560 $413,231

17501800 - - 560 $483,591 1200 - - 560 $516,539

20001800 - - 560 $576,280 1200 - - 560 $578,523

Consult factory for 315 frame & smallerConsult factory for 449 frame & smaller

Footnotes: 1 - Suitable for 2:1 CT operation2 - Form wound coil design3 - Copper bar rotor design4 - 1.2 Service Factor5 - Fixed CCW rotation, viewing opposite shaft of motor6 - Sleeve Bearing7 - Includes 100Ω Platinum Winding RTD's & Bearing RTD's

ENDURANCE SERIESTM

MOTORSTOTALLY ENCLOSED FAN COOLEDMEDIUM VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting• Cast iron frame and brackets• MAXGUARD® Class F insulation system• NEMA®* Design B• IP54 minimum• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

*NEMA is a trademark or tradename of National Electrical Manufacturers Association and is not owned by or under the control of Regal Rexnord Corporation.

BT

O M

V T

EFC

MO

TO

RS

Page 19: UNLEASH THE POWER OF REGAL REXNORD

1817

ENDURANCE SERIESTM

MOTORSTOTALLY ENCLOSED AIR TO AIR COOLEDMEDIUM VOLTAGE

BUILD TO ORDER FEATURES• Rigid, Horizontal Mounting • Fabricated frame & cast iron brackets (IEC®*) • MAXGUARD® Class F insulation system • IP55 minimum• 60 Hertz• 40°C Ambient• 3300 FSL max• Three year warranty

TEAAC - MEDIUM VOLTAGE

HP RPMIEC FRAME DESIGNS

FRAME LIST PRICE (USD) FOOTNOTES

3503600 Consult Factory 1800 355 $140,769 2,3,71200 355 $158,246 2,3,7

4003600 Consult Factory 1800 355 $145,467 2,3,71200 355 $177,098 2,3,7

4503600 Consult Factory 1800 355 $150,180 2,3,71200 400 $180,406 2,3,7

5003600 Consult Factory 1800 355 $165,165 2,3,71200 400 $183,714 2,3,7

6003600 Consult Factory 1800 400 $180,134 2,3,71200 400 $205,300 2,3,7

7003600 Consult Factory 1800 400 $181,796 2,3,71200 450 $216,418 2,3,7

8003600 Consult Factory 1800 400 $183,442 2,3,71200 450 $234,605 2,3,7

9003600 Consult Factory 1800 450 $212,173 2,3,71200 450 $255,783 2,3,7

10003600 Consult Factory 1800 450 $225,859 2,3,71200 450 $274,861 2,3,7

12503600 Consult Factory 1800 450 $232,158 2,3,71200 500 $291,311 2,3,7

15003600 Consult Factory 1800 500 $257,883 2,3,71200 500 $326,795 2,3,7

17503600 Consult Factory 1800 500 $288,902 2,3,71200 560 $359,287 2,3,7

20003600 Consult Factory 1800 500 $388,289 2,3,71200 560 $393,274 2,3,7

Footnotes: 2 - Form wound coil design3 - Copper bar rotor design7 - Includes 100Ω Platinum Winding RTD's & Bearing RTD's

Consult factory for 315 frame & smaller

* IEC is a trademark of International Electrotechnical Commission and is not owned by or under the control of Regal Rexnord Corporation.

BT

O M

V T

EA

AC

MO

TO

RS

Page 20: UNLEASH THE POWER OF REGAL REXNORD

2019

BU

OP

TIO

NS

*NEMA is a trademark or tradename of National Electrical Manufacturers Association and is not owned by or under the control of Regal Rexnord Corporation.

FEATURES ODP TEFC WPII TEAAC TEWAC

Altitude/Ambient

Altitude - Above 3300', up to 5000' $3,037

Ambient - Above 40°C, up to 60°C $2,515

Ambient - Below -25°C CONSULT FACTORY

Balance

Precision Balance $2,747

Special Balance CONSULT FACTORY

Bearing

Roller Bearing (DE)*** $25,999

Insulated Bearing (NDE)** $2,743 ² $2,743 $2,743 ³ $2,743 ³ $2,743 ³

Oil Site Gauge CONSULT FACTORY

Oil Sump Heater CONSULT FACTORY

Sleeve Bearing CONSULT FACTORY

Blowers

Radial Blower CONSULT FACTORY

Brackets

FF-Flange - DE (IEC Frames Only) $3,224 $3,224 $3,224 $3,224 $3,224

NEMA®* - C-Face - DE (NEMA Frames Only) $2,892 ¹ $2,892 $2,892 ¹ NA NA

NEMA - D-Flange - DE (NEMA Frames Only) $3,224 $3,224 $3,224 NA NA

Conduit Box

Accessory Auxiliary Box STANDARD WITH ACCESSORIES

Cable Gland Installed CONSULT FACTORY

Drain/Breather Installed $2,743 ¹

Oversized Box CONSULT FACTORY

Coupling

Customer Half Coupling Installed CONSULT FACTORY

Drain & Breathers

Brass Drain & Breather NA $338 NA $338 $338

Stainless Steel Drain & Breather NA $519 NA $519 $519

Encoder/Tachometer

Provisions (Tether Mount) CONSULT FACTORY

Installed CONSULT FACTORY

Frequency

60Hz to 50Hz Rerate CONSULT FACTORY

Grease/Lubrication/Fittings

High Temperature Grease $543

Low Temperature Grease $543

Oil Mist System CONSULT FACTORY

Grounding

Shaft Grounding Brush** $435

Shaft Grounding Ring** LOW VOTLAGE = $1,810 MEDIUM VOLTAGE = $3,714

Hardware

Stainless Steel CONSULT FACTORY

Leads

Longer Leads ($ per ft) $398

Special Terminal Requirement CONSULT FACTORY

Low Noise

Low Noise Abatement CONSULT FACTORY

Mounting/Assembly-Terminal Box Location

IEC®*-Low Voltage F3 F3 NA NA NA

IEC-Medium Voltage F1 / F2 F1 / F2 F1 / F2 F1 / F2 F1 / F2

NEMA®*-Low Voltage & Medium Voltage F1 / F2 F1 / F2 / F3 F1 / F2 F1 / F2 F1 / F2

Nameplate/Markings

Additional Data on Nameplate $350

Replacement Nameplate $761

Rotation Arrow $495

Separate Auxiliary Nameplate $676

ENDURANCE SERIESTM

MOTORSBUILD UP OPTIONS

** - Not Available on Division 2 motors*** - Not Available on 2 pole designs

¹ - Not available on ODP 5000 & 5800 frames² - Includes auxiliary box to route accessories to³ - Standard on IEC frames

Page 21: UNLEASH THE POWER OF REGAL REXNORD

2019

BU

OP

TIO

NS

BUILD UP OPTIONS / MODIFICATIONS DESCRIPTIONSALTITUDE / AMBIENTThe rating of standard motors assumes operation at sea level. Listed motors are suitable for operation at altitudes up to 3,300 feet in a maximum ambient temperature of 40°C within Class B rise limits when operated at rated horsepower. The ambient temperature is the temperature of the cooling medium surrounding the motor. All standard motors are suitable for operatation over the range of -15°C to 40°C ambient per NEMA®* MG-1.

The cooling effect of ventilating air is a function of its density. The air at higher altitudes is rarer and cannot remove as much motor heat, causing the motor to run hotter. When running a motor above 3,300 feet, the following alternatives are available to keep a standard rated motor within safe operating temperature limits:

A. Operating a standard sea level rated motor at less than rated load above 3,300 feet will reduce any heat problem. For example, a motor with a 1.15 service factor can be operated at altitudes up to 9,000 feet, with a 1.0 service factor.

B. If the motor is operated in a lower ambient temperature, it need not be modified for high altitude operation. For example, in a maximum ambient temperature of 30°C, a standard sea level rated motor can operate up to 6,000 feet. At 20°C maximum ambient temperature, a standard sea level rated motor can operate up to 9,900 feet.

Motors applied per A and B above do not require any additional charge for altitude and will not bear any special altitude or temperature data on the nameplate. The alternate to the above suggestion is to design a motor specially for the application, with appropriate data stamped on the nameplate.

ALTITUDE / AMBIENT – Frame size and performance may change with an altitude/ambient modification.

ALTITUDE RERATE – Special motor designed with appropriate data stamped on the nameplate. Frame size and performance may range with an altitude modification for motors rotating at 3,301 to 9,900 feet retaining a 40°C maximum ambient and with no change in service factor.

HIGH AMBIENT TEMPERATURE RERATE – Ambient temperature is defined as that temperature which the motor will see in the surrounding air as an expected maximum. The standard ambient is 40°C. Standard motors are designed so the temperature rise produced within the motor, added to the standard 40°C ambient temperature, will not exceed the safe winding insulation temperature limit of the motor's insulation system when in operation at maximum load conditions. Frame size, insulation class, bearings and grease may change with an ambient modification for motors operating outside the ambient envelope of the motor outside the ambient envelope of the motor.

LOW AMBIENT TEMPERATURE RERATE – For low ambient temperatures below -15°C , frame size, bearings and grease may change with an ambient modification for motors operating outside the ambient envelope of the motor.

BALANCE / VIBRATIONAll Marathon® AC motors are dynamically balanced to achieve vibration levels below NEMA Standards. The amplitude of vibration is measured in accordance with NEMA Standard MG-1 Part 7. The standard balance is 0.15 inches/second peak for 2- through 6-pole and 0.12 inches/second peak for 8-Pole and slower motors. When ordering, specify the level of balance, precision or special.

PRECISION BALANCE – Precision AC motor balancing is 0.05 inches/second per NEMA Standard MG-1 Part 7. Vibration is measured on all three axes using five separate locations. Motors with roller bearings are not available with vibration limits at the precision levels.

SPECIAL BALANCE – Special balance is 0.08 inches/second peak for 2- through 6-Pole motors and 0.06 inches/second peak for 8-Pole and slower motors. Special balance is standard on inverter duty, automotive and severe duty motors. Additionally, special balance is not available on 2-Pole (3600 RPM). Special balance levels are not available on motors with roller or sleeve bearings.

Vibration - Inches/Sec

RPM SPECIAL PRECISION

3000-4000 0.0005 0.0003

1500-2999 0.0008 0.0004

1000-1499 0.0010 0.0005

999 & Slower 0.0013 0.0007

BEARINGSAll standard motors use anti-friction deep groove Conrad type ball bearings, sized for the loads to be expected in industrial applications. These are of the AFBMA type BC with C-3 fit. Roller bearings are used on the drive end to handle heavy or overhung (radial) shaft loads.

CONVERT BALL TO ROLLER BEARING (DRIVE END) - Roller bearings are used where high radial loads are present for an improved L10 life in belted applications. This modification requires that the belting requirements are provided prior to order acceptance. Available on 1800 RPM and slower motors. Roller bearings are available as open type only (no shields or seals). They are not available on flange mounts where no radial load is applied and are not available for direct coupled applications.

FLOOD LUBRICATION SYSTEM - Flood lubrication is used where it is not possible to use an oil ring, or in applications, where additional bearing cooling is required.

INSULATED BEARING - Insulated bearings are used to prevent the transmission of shaft currents which can cause electrical arcing (bearing fluting) and premature bearing failure. Insulated bearings provide a thin, non-conductive aluminum oxide coating on the machined outer race of the bearings. This thin coating electrically insulates against bearing currents, however, it does not act as a "thermal insulator". In most applications, the opposite drive end bearing is insulated to break the electrical path of the circuit. If insulated bearings are required on both ends, double the adder. If roller bearings are required, the opposite shaft end will always be insulated.

OIL SITE GAUGE - A brass fluid gauge with a sight glass acts as a fluid level indicator and provides a means to view the level of oil in the bearing housing.

OIL SUMP HEATER - Oil sump heaters are required in sleeve bearing motors in ambient temperature from -40°C to -10°C. These heaters are thermally self-limited by watt density and thermal capacity of the oil reservoir. Heaters are ony available in 115V, 60 Hz. This modification includes heaters for drive and opposite-drive end sleeve bearings.

*NEMA is a trademark or tradename of National Electrical Manufacturers Association and is not owned by or under the control of Regal Rexnord Corporation.

Page 22: UNLEASH THE POWER OF REGAL REXNORD

2221

BU

OP

TIO

NS

FEATURES ODP TEFC WPII TEAAC TEWAC

Packaging

Crating CONSULT FACTORY

Export Packaging CONSULT FACTORY

Paint

Stock Marathon® Motor Color 2% Adder

Special Color CONSULT FACTORY

Protection-Current and Voltage

Current Transformer CONSULT FACTORY

Potential Transformer CONSULT FACTORY

Protection-Mechanical

Accelerometer $6,448

Vibration Sensor Provision $1,364

Vibration Sensor Installed $8,308

Protection-Surge

Lightning Arrestors CONSULT FACTORY

Surge Capacitors CONSULT FACTORY

Protection-Thermal

Bearing Temperature Detectors (BTDs) 100Ω Platinum $4,166²

Stator Temperature Detectors (RTDs) 100Ω Platinum $4,902²

Thermistor Control Module $1,162

Thermistors-Winding $1,413²

Thermostats (N/C) $1,461²

Thermostats (N/C) - Hermetically Sealed $1,703²

Service Factor

Service Factor Rerate CONSULT FACTORY

Shaft Modification

Shaft Extension (Length, Keyway, Tapered, etc) CONSULT FACTORY

Shaft Features (Internal Thread, Milled Flat, Material) CONSULT FACTORY

Shaft Seals

Labyrinth Seals NA $2,320 NA NA NA

Radial Lip Seals $2,898

V-Ring Seals $1,105

Space Heater

Space Heater-Standard (120V or 240V or 460V) $1,618²'³Space Heater-Silicone Free (120V or 240V) $1,980²'³Testing

Unwitnessed - Complete Initial Test $17,968

Unwitnessed - Polarization Index Test $4,818

Unwitnessed - Sound Test $4,818

Unwitnessed - Vibration Test $2,898

Witnessed - Complete Initial Test $30,948

Witnessed - Sound Test $7,704

Witnessed - Vibration Test $6,895

Torques

NEMA®* Design A, C or D CONSULT FACTORY

Torque - Special CONSULT FACTORY

Voltage

Low Voltage > 601V CONSULT FACTORY

Medium Voltage > 4160V, but < 6900V CONSULT FACTORY

Medium Voltage 6900V through 13.2KV CONSULT FACTORY

Weatherproofing / Special Service

Division 2 Hazardous Motor CONSULT FACTORY

Tropical Anti-Fungus Treatment $1,473

WPII Enclosure Options

Filter-Galvanized NA NA $1,932³ NA NA

Filter-Stainless NA NA $2,657 NA NA

Pressure Differential Switch NA NA $2,717 NA NA

ENDURANCE SERIESTM

MOTORSBUILD UP OPTIONS

² - Includes auxiliary box to route accessories to³ - Standard on IEC frames

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: IEC is a trademark of International Electrotechnical Commission; NEMA is a trademark or tradename of National Electrical Manufacturers Association. 

Page 23: UNLEASH THE POWER OF REGAL REXNORD

2221

BU

OP

TIO

NS

BUILD UP OPTIONS / MODIFICATIONS DESCRIPTIONSSLEEVE - Sleeve bearings are use for both ODP & TEFC applications. They are supplied with oil reservoirs, ring oilers, sight gauge, marked magnetic centers, and oil fill and an oil drain. Motors with sleeve bearings are not suitable for belted applications. The temperature range of sleeve bearings are limited to ambient temperature extremes of -10C to 40°C. For ambient temperatures below -10°C, an oil sump heater is required.

BLOWERSLow rotational speeds, common in many variable speed applications, cause additional heat within the motor. The use of an auxiliary blower may be required at these lower rotational speeds to mitigate damage due to the additional heat generated. The National Electrical Code 430-126(b) mandates that motors with external force-ventilation have a form of thermal protection. This protection is included when modifying the motor for forced ventilation

RADIAL BLOWER - A radial blower, in which air is forced ventilated from the top (or side) into a chamber on the non-drive end of the motor and air is forced over the frame. Blower voltages are single or three phase. Specify voltage and phase when ordering.

BRACKETS / FLANGES - Standard drive end bracket can be replaced with either a C-Face or D-Flange mounting.

C-FACE - A C-Face bracket consists of a male rabbet and tapped holes for mounting bolts typically used for direct mounting of pumps.

D-FLANGE - D-Flange bracket consists of a male rabbet, with holes in the flange for thru-bolts. This flange is typically used on direct mounting of gear drives.

CONDUIT / TERMINAL BOXStandard conduit/terminal box construction is based on the individual product description. A fabricated steel box is standard on larger frames. Conduit boxes meet or exceed 430.12 requirements for volume. Termination of protective or monitoring devices are provided in a separate auxiliary conduit box.

CABLE GLAND - Modification provides metal industrial grade cable glands for outlet opening on conduit/terminal box. The customer needs to provide the cable size and type, cable gland manufacturer with type and model number when ordering so the proper cable gland can be selected.

CONDENSATION HOLE/BREATHER - Addition of a condensation hole and breather to the conduit/terminal box to release moisture.

NEMA II TERMINAL BOX/STANDOFF BUS INSULATORS - NEMA®* Type II terminal box with bus bar termination on standoff insulators.

OVERSIZED CONDUIT/TERMINAL BOX - Add oversized fabricated conduit/terminal box in place of standard box with larger NEMA minimum volume.

SPACE HEATER IN CONDUIT / TERMINAL BOX - Addition of 115 VAC single phase space heater with leads brought out to auxiliary terminal box.

COUPLINGSCustomer supplied rigid, flexible, pinion couplings and V-Belt sheaves can be pressed on and dynamically balanced. Couplings, pinions or sheaves must be finish-bored and key seated to Marathon® motor shaft dimensions and must be shipped to plant freight prepaid. Lead-time is a combination of the delivery time of the component and time to perform the modification.

MOUNTING OF CUSTOMER SUPPLIED COUPLINGS - Customer's one-piece coupling half can be mounted on the shaft. The coupling half must be pre-balanced, finished machined and key seated and sent transportation prepaid to the factory. Motor vibration characteristics will be measured after coupling installation, however, the motor will not be rebalanced after coupling assembly.

DRAINS & BREATHERSStandard duty motors include a weep hole and closable plugs as standard. These are located in the drive end bracket or frame, at the lowest point. The drain hole plugs are open on delivery and users must ensure that the drain holes face downward when mounting the motor.

304 STAINLESS STEEL DRAIN & BREATHER - Combination self-draining and breather plugs are available on TEFC motors. Maximum enclosure rating is IP56 with breather.

ENCODERSThese electrical devices sense rotor speed and direction providing feedback to a control device. An encoder is a feedback device that translates mechanical motion into an electrical signal. A cable is connected from the encoder to the variable frequency drive to provide this feedback. Various mechanical provisions on the motor are required to attach the encoder. These may include C-Face on the non-drive end of the motor and special shaft extension. Various resolutions are available. All encoders offered have quadrature signal with line driver output.

DYNAPAR®* ENCODER - The Danaher®* HS35 encoder is provided as standard. Specify the type of termination (10 pin MS connector, industrial connector or M12 euro-style) required at time of order.

FAN / FAN COVERMotors incorporate an aluminum fan as standard.

LOW NOISE FAN COVER - Sound reducing foam-lined noise cancelling fan cover in lieu of traditional fan cover.

STEEL FAN - A steel fan in place of the standard aluminum fan.

FRAME / BASEThe motor frame consists of the enclosure constructed of fabricated steel or cast iron and configurated as open drip proof, weather protected I (WPI), weather protected II (WPII), totally enclosed air-to-air cooled (TEAAC), totally enclosed air-to-water cooled (TEWAC) or totally enclosed enclosed fan cooled (TEFC). Mounting arrangement will be horizontal, face or flange mounted with or without feet.

DOWEL PIN HOLES - For locating and alignment purposes, two dowel pin holes, one on each foot, diagonally opposite each other 1/4 inchdiameter, can be provided. The modification includes the dowel pin pilot holes with the pins supplied by others.

FOOT FLATNESS - Special 0.005" foot flatness from mounting hole tomounting hole. Available on cast iron 5000 Frame motors.

VERTICAL JACKING PROVISION - Four tapped holes are provided on the motor's feet to assist the installer in proper alignment of the motor shaft with the driven piece of equipment for shimming purposes. A 1/2-13 UNC treated hole on 400 through 5013 Frames. Bolts supplied by customer.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: Danaher/Dynaper are trademarks or tradenames of International Electrotechnical Commission; NEMA is a trademark or tradename of National Electrical Manufacturers Association. 

Page 24: UNLEASH THE POWER OF REGAL REXNORD

2423

BU

OP

TIO

NS

BUILD UP OPTIONS / MODIFICATIONS DESCRIPTIONSFREQUENCYMost motors commonly operate on 60 hertz (HZ) within North America.

FREQUENCY RERATE 60 HZ TO 50 HZ - Manufacturer's standard motor rating is 60 Hz, but may be operated at 50 Hz at reduced voltage and horsepower or Service Factor. A label containing specific re-rating information will be attached to the motor. Frame size is subject to change.

GREASE / LUBRICATION / FITTINGSStandard grease is Exxon Polyrex®* EM with a bearing operating temperature range of -30°C to +150°C for ball bearings.

HIGH TEMPERATURE GREASE - Bearing grease may be changed to allow for a higher operating range. The motor bearings and end bells are purged and repacked with Dow Corning®* DC44M grease or equivalent with a temperature range of -40°C to +204°C.

LOW TEMPERATURE GREASE - Bearing grease may be changed to allow for a lower operation range. The motor bearings and end bells are purged and repacked with Beacon 325®* grease or equivalent with a temperature range of -60°C to +120°C.

OIL MIST SYSTEM - The modification includes provisions to accommodate oil mist lubrication system. Motors will be modified to accept an external oil mist lubrication system. The bearing cavity is arranged for oil mist, but the bearings will be packed with grease for normal operation. Prior to the oil mist lubrication system being connected, the bearings and bearing cavities need to be purged and cleaned so grease/oil is compatible and does not affect performance and reduce bearing life. The oil mist lubrication system is supplied by others and consists of a centralized system where compressed gas is used to atomize oil. The oil is then conveyed by air in a low pressure distribution system to fittings on the motor that meter the oil to the bearing housings.

GROUNDINGAll motors have grounding provisions per NEMA®* and NEC Standards.

ON-FRAME GROUNDING - Addition of drilled and tapped hole on conduit box side of frame with installation of bronze grounding lug. These provisions are typically a drilled and tapped hole either 1/4-20 or 3/8-16 and can be located on a frame foot or on flange of a vertical motor.

SHAFT GROUNDING RING - Shaft grounding rings are recommended (NEMA MG131.4.4.3) as an effective means of bearing protection for motors operated from inverter power. One ring is adequate to bleed down inverter-sourced shaft voltages, thereby protecting both bearings for motors.

HARDWAREStandard hardware is non-corrosive, zinc-plated grade 5.

304 STAINLESS STEEL HARDWARE - 304 stainless steel fasteners for holding brackets, conduit box, fan cover, nameplates and T-Drain are available on all frame sizes. It does not include grease fittings, eyebolts or any other components.

316 STAINLESS STEEL HARDWARE - 316 stainless steel fasteners for holding brackets, conduit box, fan cover, nameplates and T-Drain are available on all frame sizes. It does not include grease fittings, eyebolts or any other components.

INSULATIONMarathon® motors incorporate a non-hygroscopic Class F (utilizing Class H components) vacuum pressure solvent less impregnation system. Special epoxy resins are applied over form-coiled, mica tapped insulation. Conductive and semi-conductive tapes are used to insulate the coils to ensure improved resistance to corona. This system meets the definition of NEMA MG1-1.27.1 as encapsulated for moisture resistance and also passes the testing required in NEMA MG1-12.63.

CLASS H INSULATION SYSTEM - A Class H (180°C) insulation system provides additional thermal endurance when operating at the limiting Class H temperature specified in the temperature rise standard.

CORROSION RESISTANT COATING FOR STATOR & ROTOR - This modification provides corrosion epoxy coating on the stator and rotor for added protection against corrosive environments.

VACUUM PRESSURE IMPREGNATION - Provides maximum winding protection against harsh environments. 100% Class F epoxy solids are forced into windings, filling slots and insulation making them virtually void free.

LEADSAll motors are provided with standard leads of ample length for easy connection in the conduit/terminal box to the power leads. Lead size and material are dependent upon the class of insulation system in the motor and the current capacity required. Lead length is measured from the face of the frame and extends a minimum of four inches beyond the face of the conduit terminal box base. All medium voltage motors come standard with single hole terminal lugs.

LONGER LEADS - UNSPLICED - Extended leads are available up to 60 inches in 12 inch increments.

TERMINAL LUGS - Add Burndy two hole lugs in place of standard terminal lugs.

MOUNTING / ASSEMBLYMotors listed are horizontal, foot mounted, clockwise (CW) rotation as viewed from the drive end of the motor.

F1 TO F2 MOUNTING CONVERSION - Relocate conduit/terminal box from F1 to F2.

NAMEPLATES / MARKINGSNameplates are etched 400 Series stainless steel. Nameplate data is provide per NEMA Standard 20.25.

ADDITIONAL DATA ON NAMEPLATE - The main motor nameplate can include additional customer information (48 characters maximum).

FOREIGN LANGUAGE NAMEPLATE - Nameplates are available in a foreign language with an English character alphabet (A, B, C,…Z). Languages using special characters and/or symbols are not available. A standard English motor nameplate will be provided on all motors in addition to the foreign nameplate. Specify language at time of order.

PRIVATE LABEL NAMEPLATES - Private label nameplates can be furnished but data must be submitted at time of order.

REPLACEMENT NAMEPLATE - A duplicate replacement can be provided, but will not have CSA®* or UL®* Listings.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: CSA is a trademark or tradename of CSA Group; Exxon Polyrex and Beacon 325 are trademarks or tradenames of Exxon Mobil Corporation; Dow Corning is a trademark or tradename of Dow Silicons Corporation; NEMA is a trademark or tradename of National Electrical Manufacturers Association; UL is a trademark or trade name of Underwriters Laboratories.

Page 25: UNLEASH THE POWER OF REGAL REXNORD

2423

BU

OP

TIO

NS

ROTATION ARROW - Metal plate mounted on motor with arrow showing direction of rotation. Specify rotation facing shaft extension on order entry form.

SEPARATE NAMEPLATE FOR CUSTOMER DATA - A separate customer nameplate can be furnished. Information contained must be submitted at time of order. These additional nameplates cannot be supplied with CSA®* or UL®* Listings.

304 STAINLESS STEEL NAMEPLATE - Replace existing nameplate with 304 stainless steel nameplate.

PACKAGINGManufacturer incorporates wooden skids with wrapping for shipping purposes.

EXPORT PACKAGING - Rugged wood crating of motors is available to protect the product from damage due to excessive shipping and handling, as well as below deck shipments. Export marks, size and weight would be stenciled on each crate.

PAINTThe standard paint finish is a two-coat paint system. The first coat is a rust-inhibitive primer applied to protect the castings during storage and manufacturing. The second coat is a 2-part epoxy. Special paints and color options are available if compatible and reviewed by Application Engineering. Paint chips and material safety data sheets are required.

REPAINT TO A MARATHON® MOTOR STOCK COLOR - Repaint motor to another Marathon stock paint color. Specify color on order.

RAL COLOR COLORRAL5011 BlueRAL9017 Black

Green RAL9003 WhiteRAL3003 RedRAL1018 Yellow

PAINT-SPECIAL COLOR - Special colors are available, but must be approved by Mod Central. A material safety data sheet (MSDS) must be furnished prior to painting. Special paint can be furnished (once approved) if compatible with Marathon's standard paint/primer, and are available commercially. Paints must be suitable for air drying and must not contain lead or zinc.

PRINTS & DATAStandard prints and data are available at no charge with up to five sets at time of order and consist of the following: certified dimension print, performance data, nameplate data, instruction manual, wiring diagram, parts, list, bearing life calculation, major component weights, paint specification, rotor air gap, rotor inertia, and cut sheets for accessories. Data is provided as quality black print on white paper, suitable for reproductions.

ACCELERATION TIME VS AMP CURVE - Acceleration time vs amp curve is available. Five reports are provided to the customer.

CERTIFICATE OF CONFORMANCE - A certificate of conformance is available. Five reports are provided to the customer.

PERFORMANCE CURVES - Performance curves are available. Five reports are provided to the customer.

ROTOR DETAIL PRINT - Rotor detail print data is available. Five reports are provided to the customer.

SHAFT PRINT - Shaft print data is available. Five reports are provided to the customer.

SHAFT STIFFNESS - Shaft stiffness curves are available. Five reports are provided to the customer.

SPEED VS TORQUE & AMP CURVE - Speed vs torque and amp curves are available. Five reports are provided to the customer.

STALL TIME CURVE - Safe stall time curves are available. Five reports are provided to the customer.

UL CERTIFICATE - UL certification is available. Five reports are provided to the customer.

PROTECTIONCURRENT AND VOLTAGE - Current and potential (voltage) transformers provide inputs to protective and predictive motor protection relays that protect the motor against overloads, short circuits and abnormal operating conditions. The conduit/terminal box will be oversized.

CURRENT TRANSFORMER - Ground Fault Protection Window-type current transformer (one per phase) are provided for protection against a winding fault ground.

CURRENT TRANSFORMER - LOAD MONITORING/PROTECTION - A single window-type current transformer (50:5) is mounted in the conduit/terminal box for load monitoring and current protection.

POTENTIAL TRANSFORMER - A 600 VAC 60 Hz primary potential transformer, 10kV BIL for load monitoring and metering.

PROTECTION - MECHANICALVibration/temperature protection devices detect potential problems by measuring and analyzing the vibrattion and temperature of the motor. These devices provide maintenance and plant supervisors with a means of identifying vibration, temperature, or bearing problems in a motor eliminating the possibility of equipment down time. Detectors are for single-direction monitoring (horizontal, vertical or axial) or total coverage of all three directions, three detectors must be used. Monitoring direction must be specified at time of order.

ACCELEROMETER - Accelerometer is used to sense bearing housing vibration on motors with anti-friction or sleeve bearings. Specify Metrics, BALLMAC or Bentley-Nevada®* at time of order.

VIBRATION SWITCH - These devices are mounted on the unit and detect vibration in any of three planes to signal a device when pre-set limits of vibration are exceeded.

PROTECTION - SURGESurge protection consists of surge capacitors and lightning arrestors. Surge capacitors reduce the steepness of a power surge front and lightning arrestors limit the peak voltage of such a surge. Surge capacitors are not available if the motor is used with an adjustable frequency drive.

LIGHTNING ARRESTORS - Station class metal oxide surge arrestors are supplied as standard.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: Bently-Nevada is a trademark or tradename Baker Hughes Company; CSA is a trademark or tradename of CSA Group; NEMA is a trademark or tradename of National Electrical Manufacturers Association; UL is a trademark or trade name of Underwriters Laboratories.

BUILD UP OPTIONS / MODIFICATIONS DESCRIPTIONS

Page 26: UNLEASH THE POWER OF REGAL REXNORD

2625

BU

OP

TIO

NS

SURGE CAPACITORS - The surge capacitors consist of porcelain bushings with an all-film unit utilizing Faradol 810, a non-PCB bio-degradable dielectric fluid. Internal discharge resistors provide a five minute discharge time afte de-energization.

SURGE PROTECTION PACKAGE - The surge protection package consists of surge capacitors connected in parallel with the lightning arrestors controlling the rise of the resultant over-voltage. The combination of surge capacitors and arrestors serves to limit the turn-to-turn insulation stress impressed on the motor.

PROTECTION - THERMALThermal protection is built in protective devices that prevent motor overheating. They work either by interrupting the power supply when the motor overheats or by incorporating a pilot device that opens the holding circuit of a magnetic starter or energizes an alarm bell or warning light.

BEARING/STATOR TEMPERATURE DETECTOR (RTDS) - RTDs are precision wire-wound resistors with calibrated temperature resistance characteristics. The standard arrangement is the addition of a 100ohm platinum RTD to the bearing housing with the leads brought out to the conduit box. These devices are used in conjunction with customer supplied instrumentation or indicating devices.

THERMISTORS - CONTROL MODULES - Control modules are available for thermistors. Shipped loose for customer installation. Specify 120 VAC or 240 VAC control power on order.

THERMISTORS - WINDING - Thermistors are small, non-linear resistance devices placed on the stator windings. As the critical temperature is reached, the resistance of the thermistor changes radically, causing operation of a control relay. The standard arrangement is Q-3 positive temperature coefficient (PTC) type on winding end-turns with leads brought out to the conduit box. Normally, 3 Texas Instruments®* thermistors are furnished, one per phase. Available on non-explosion proof motors.

THERMOSTATS - WINDINGS - Thermostats are mounted on the stator winding and are temperature-sensing only. They are available with normally open or normally closed snap action contacts. These devices are installed on the end-turns of the motor winding. Their purpose is to activate a warning device or shut down the motor upon excessive winding temperatures. The standard arrangement is the addition of 2 or 3 thermostats to the winding end-turns, connected in series with the leads brought out to the conduit box. Specify normally open or normally closed upon order entry. Modification does not include temperature read-out device.

SERVICE FACTORThe service factor of a motor is a multiplier which when applied to the nameplate horsepower of a motor indicates the highest permissible load that can be applied without exceeding insulation temperature limits for the conditions of usage. On non-fluctuating loads, it would indicate the maximum continuous duty cycle horsepower that could be sustained.Operating at service factors above 1.00 does not change locked rotor or breakdown torque capabilities, but current draw, efficiency and power factor will change as will heat rise, shortening the life of the motor. Standard stock motors are designed for 1.15 service factor unless otherwise noted.

SERVICE FACTOR RERATE - Higher service factors are available, but may require an increase in frame size or a special design.

SHAFT MODIFICATIONMotors are furnished with a single straight shaft with key.

ADDITIONAL SHAFT LENGTH - Longer than standard shaft extensions are usually suitable for direct connections. Other drives such as belts or gearing may require special bearing arrangement.

DOUBLE SHAFT - Add stub shaft to accommodate addition of HS style encoder on the opposite drive end of the motor.

DRILL & TAP HOLE - Drilled radially or in the end of the shaft. Drilled and tapped in the end of the shaft. Provide details of drill/tap hole with order.

LOCKNUT ON END OF SHAFT - A locknut can be supplied when an external thread on the shaft extension is required.

MILL FLAT ON SHAFT - Mill a flat on the drive end shaft extension. Provide detail of flat with the order.

SPECIAL KEYWAYS - Special flat, woodruff and tapered keyways are available. A diagram is required at time of order.

STEPS ON SHAFT - One to three reductions in shaft diameter. Customer to specify number of reductions at time of order.

TAPERED SHAFT - 1-1/4 or 1-1/2 inch per foot taper with threads, nut, and lock washer.

THREADED SHAFT - Class 2A right-hand thread of size appropriate to the shaft diameter. Provide details of threaded shaft with order.

304 STAINLESS STEEL - 304 stainless steel is the most versatile and most widely used stainless steel. Excellent in a wide range of atmospheric environments and many corrosive applications. Subject to pitting and crevice corrosion in warm chloride environments and to stress corrosion cracking above 60°C.

316 STAINLESS STEEL - 316 stainless steel has better overall corrosion resistant properties than grade 304, particularly higher resistance to pitting and crevice corrosion in chloride environments. 316 stainless steel is usually regarded as the standard "marine grade stainless steel", but it is not resistant to warm sea water. In many marine environments, 316 stainless steel does exhibit surface corrosion.

416 STAINLESS STEEL - 416 stainless steel offers corrosion resistance to dry atmospheres, fresh water and mild alkalines and acids, but offers less corrosion resistance than 304 and 316 grades.

4142 HIGH CARBON STEEL - 4142 carbon steel is a chromium-molybdenum alloy steel that provides good hardiness, resists creep in high temperature and possess good wear resistance.

SHAFT SEALSShaft seals are installed on the shaft at the bracket face to prevent the ingress of dirt and liquid.

LABYRINTH SEALS- Labyrinth seals incorporate a two-part machinednon-ferrous unit that has an outer part as a press fit to the motor bracket and inner race press fit to the shaft. These are non-contact seals and provide the greatest degree of protection, IP56. Inpro/Seals®* are normally furnished.

NEOPRENE SLINGER - Slingers are a large rubber washer-like device that helps restrict flow of debris into the gap between seal and shaft and bracket as the shaft exits. It consists of a flexible material, generally neoprene, that has an interference fit to the shaft and rotates with it.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: Inpro/Seal is a trademark or tradename of Dover Corporation; Texas Instruments is a trademark or tradename of Texas Instruments Incorporated.

BUILD UP OPTIONS / MODIFICATIONS DESCRIPTIONS

Page 27: UNLEASH THE POWER OF REGAL REXNORD

2625

BU

OP

TIO

NS

RADIAL LIP SEALS - These seals provide a unit which has a press fit outer race that is pressed into the bracket or bearing cap. The shaft is specially machined for size and surface finish to limit wear in the area where a flexible lip contacts it, hence the name "lip seal". These seals provide protection against dust and these seals have an inference fit to the shaft and rotate with it. They have a flexible lip which will contact a bracket face that has been specially prepared. These units provide protection against dust and water entry to an IP54 or IP55 rating.

SPACE HEATERSSpace heaters are used to prevent the build-up of condensation on the windings of the motor when the motor is not operating. Space heaters are typically installed on the end-turns of the coils.

SPACE HEATERS - ODP & TEFC - Space heaters can be furnished on dripproof and totally enclosed motors. Heater leads are normally brought out to the motor's auxiliary box and marked H1 and H2. Heater voltage is available in three voltages for 60 Hz operation of 120, 230 or 460 volt, single-phase. Space heaters are sized per NEMA®* standards.

TESTINGAll motors receive a short commercial test prior to shipment to ensure proper operation and to assure conformance with electrical and mechanical specifications. Each motor is given a routine test per NEMA and IEEE Standard 112. Test results for motors are shipped with each motor.

CALIBRATION TEST - A calibration test consists of 0-125% rated lead test measurement of speed, torque, current, power factor and efficiency at rated voltage. Five test reports are provided to the customer.

COMPLETE INITIAL TEST - A complete initial test consists of full-load heat run, percent slip, no load current, full-load current, locked rotor current, locked rotor torque, breakdown torque (calculated), efficiency and power factor, winding resistance, high potential and bearing inspection. This test is performed in accordance with IEEE112 Method B. Five test reports are provided to the customer.

EFFICIENCY TEST - Motor efficiency is determined by NEMA Standard MG-1 Part 12.59 and in accordance with IEEE Standard 112 or Canadian Standards Association Standard C390. Five test reports are provided to the customer.

HIGH-POTENTIAL TEST - The high-potential test consists of the application of a voltage higher than the rated voltage for a specified time for the purpose of determining the adequacy against breakdown of insulation materials and spacings for normal conditions. This procedure meets NEMA Standard MG-1 Part 3 and pertinent IEEE Standards. Five test reports are provided to the customer.

POLARIZATION INDEX TEST - The polarization index test is a specialized application of the dielectric absorption test. The polarization index is ratio of the insulation resistance at 10 minutes to the insulation resistance at one minute. Five test reports are provided to the customer.

ROUTINE TEST - Manufacturer performs routine tests on each motor manufactured per NEMA Standard MG-1 Part 12.56 and in accordance with IEEE Standard 112. These include measurement of winding resistance, no-load readings of current and speed at normal voltage and frequency current input at rated frequency at locked rotor and high potential test.

SOUND TEST - Sound quality is determined by the distribution of effective sound intensities as a function of frequency. It plays a significant role in determining how acceptable the sound is to the human ear. Sound measurements are taken per NEMA Standard MG-1 Part 12.54 and in accordance with IEEE Standard 85. Tests are performed under no load conditions. Five test reports are provided to the customer.

VOLTAGESSpecial motor designs are required for other than standard nameplate voltages of 200 VAC, 230 VAC, 460 VAC and 575 VAC. Motors will operate successfully, but not necessarily in accordance with all NEMA (MG1) performance standards, at voltage ±10% of the nameplate at maintained frequencies.

VOLTAGES - SPECIAL - This modification applies to 1000 VAC 60 Hertz motors and below.

WARRANTYAll motors are warranted per Terms and Conditions of Sale, MPN411. Special warranties are available.

WEATHERPROOFING / SPECIAL SERVICEWeatherproofing or special service provides additional protection to windings and mechanical parts as well as special greases or modifications per industry specifications such as NEMA, IEEE or marine.

DIVISION 2 HAZARDOUS MOTORS - The Division 2 hazardous modification incorporates a new fan, fan guard, and nameplate to Blue Chip Series® XRI® TEFC motors. The nameplate will say CSA®* Certified, Group I, Division 2, Groups A, B, C and D, Temperature Code (T-Code).

TROPICAL ANTI-FUNGUS TREATMENT - Windings and mechanical parts coated with poly-urethane for superior protection to resist tropical environments.

WPII ENCLOSURE OPTIONSAIR TEMPERATURE SENSOR - A resistance temperature detector (RTD) can be supplied in the air flow inlet of WPII motors to monitor incoming air temperature. Winding RTDs should be provided when this option is specified. The RTD monitoring the air flow should be the same rating as the winding RTD and will be wired to the same auxiliary terminal box.

DIFFERENTIAL PRESSURE MANOMETER - A passive device that provides a visual indication of clogged filters at the motor.

DIFFERENTIAL PRESSURE SWITCH ACROSS FILTER - When this accessory is applied to WPII motors with air filters, it guards against clogged filters that restrict cooling air. An air filter differential pressure switch measures the pressure drop across the air filters. This device takes into consideration the concentration of airborne particles allowing the filter to be used until its maximum dust holding capacity is reached. Contact Marketing if the application is Division 2. Provide 304 stainless steel filter in lieu of standard.

FILTERS - WPII - Removable dry-type air filters for use only on WPII motors. The filter media provides a high dust holding capacity. These are easy to clean and replacements are readily available.

*The following trademarks are not owned by or under the control of Regal Rexnord Corporation: CSA is a trademark or tradename of CSA Group; NEMA is a trademark or tradename of National Electrical Manufacturers Association.

BUILD UP OPTIONS / MODIFICATIONS DESCRIPTIONS

Page 28: UNLEASH THE POWER OF REGAL REXNORD

Sign up to stay updated with our Industrial motors newshttp://eepurl.com/g8-fsz

The proper selection and application of products and components, including assuring that the product is safe for its intended use, are the responsibility of the customer. To view our Application Considerations, please visit https://www.regalrexnord.com/Applica-tion-Considerations.

To view our Standard Terms and Conditions of Sale, please visit https://www.regalrexnord.com/Terms-and-Conditions-of-Sale (which may redirect to other website locations based on product family).

Industrial Solutions Regal Rexnord100 East Randolph StreetWausau, WI 54402-8003Phone: 715-675-3359Fax: 715-675-8026regalrexnord.com

“Regal Rexnord” is not indicative of legal entity.

Regal Rexnord, BCP, Blue Chip Series, Endurance Series, MAX GUARD, Marathon, XRI are trademarks of Regal Rexnord Corporation or one of its affiliated companies.

©2020, 2022 Regal Rexnord Corporation, All Rights Reserved.

MCC22013E • Form# SB0270E

The following trademarks are not owned by or under the control of Regal Rexnord Corporation: CE is a trademark or tradename of European Unions; CSA is a tradename od CSA Group; Danaher/Dynaper are trademarks or tradenames of International Electrotechnical Commission; Dow Corning is a trademark or tradename of Dow Silicons Corporation; Exxon Polyrex and Beacon 325 are trademarks or tradenames of Exxon Mobil Corporation; IEC is a trademark of International Electrotechnical Commission; Inpro/Seal is a trademark or tradename of Dover Corporation; NEMA and NEMA Premium are trademarks or tradenames of National Electrical Manufacturers Association; Texas Instruments is a trademark or tradename of Texas Instruments Incorporated; UL is a trademark or trade name of Underwriters Laboratories;