Top Banner
Universal aluminium busbar system up to 6300 A plus 78 | Lafer | Smart-Energy
6

Universal aluminium busbar system up to 6300 A · • Anodized aluminium profiles with a nickel contact surface applied. • Linear system with the option to be installed in the cable

Feb 02, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Universal aluminium busbar system up to 6300 A · • Anodized aluminium profiles with a nickel contact surface applied. • Linear system with the option to be installed in the cable

Universal aluminium busbar systemup to 6300 A

plus

78 | Lafer | Smart-Energy

Page 2: Universal aluminium busbar system up to 6300 A · • Anodized aluminium profiles with a nickel contact surface applied. • Linear system with the option to be installed in the cable

Economic, innovative, flexible.

Main characteristics• Insulators made of self-extinguishing

PA6 polyamide, class V0IEC 60695-11-10.

• Anodized aluminium profiles with a nickel contact surface applied.

• Linear system with the option to be installed in the cable compartment, in rear and upper zone.

• Maximum easiness and speed in wiringwith hammer-head screws and Laferaccessories.

• Simplicity in coupling and junctionbetween bars.

• Certified system according to norm61439-1 / 61439-2.

• Short-circuit Certificationup to 105 kA.

Main characteristics• Connection system in tin-plated

aluminium up to 6300 A.• Innovative system designed to be

shaped to the connections.• System certified according to norm

61439-1 / 61439-2.• Short circuit Certification

up to 105 kA.

plus

Smart-Energy plus can be used in Lafer cabinets and in those of other brands as well.

IEC 61439-1 test n. B5002265 resistance to short circuit In=6300 A e Icc=105 kA for 1 sec.• seal test for short circuit.• masses connection test equipment and protection circuit.

IEC/TR 61641CEI 17-86

test n. B5014994 arc conditions due to internal fault 105 kA for 300 msec.

IEC 61439-1 test n. 02472-15-0378 overtemperature limit testing.• verification of the dielectric properties: Pulse tests at industrial frequency. • clearance and creepage distance verification.

Certifications

plus

Smart-Energy | Lafer | 79

Page 3: Universal aluminium busbar system up to 6300 A · • Anodized aluminium profiles with a nickel contact surface applied. • Linear system with the option to be installed in the cable

plus

Upper area.

BA25P2500 A31x100 mm

BA25P/51000 A (neutral 50%)2000 A (neutral 100%)31x100 mm

BA404000 A31x180 mm

BA40/51000 A (neutral 50%)2000 A (neutral 100%)31x180 mm

BA16P1600 A31x80 mm

BA12P1250 A31x60 mm

BA10P1000 A31x60 mm

BA8P800 A31x50 mm

BA6P630 A31x50 mm

BA32P3000 A31x120 mm

BA32P/51000 A (neutral 50%)2000 A (neutral 100%)31x120 mm

BA20P/51000 A (neutral 50%)2000 A (neutral 100%)31x80 mm

BA20P2000 A31x80 mm

Rear area.

A specific bar for every powerAnodized aluminium profiles with applied nickel contact surface.

Bars available in two lengths 1750 mm and 2325 mm.

80 | Lafer | Smart-Energy

Page 4: Universal aluminium busbar system up to 6300 A · • Anodized aluminium profiles with a nickel contact surface applied. • Linear system with the option to be installed in the cable

BA20P/51000 A (neutral 50%)2000 A (neutral 100%)31x80 mm

Compatible with Smart-Energy plus busbars and also with traditional copper bars.

Busbar holders Maximum speed of installation

3 poles busbar holder from 630 to 1600 A 4 poles busbar holder from 630 to 1600 A

3 poles busbar holder from 630 to 3200 A 4 poles busbar holder from 630 to 3200 A

3 poles busbar holder from 630 to 4000 A 4 poles busbar holder from 630 to 4000 A

3 poles busbar holder from 5000 to 6300 A 4 poles busbar holder from 5000 to 6300 A

Smart-Energy | Lafer | 81

Page 5: Universal aluminium busbar system up to 6300 A · • Anodized aluminium profiles with a nickel contact surface applied. • Linear system with the option to be installed in the cable

Tangs extensiondrawer form 4b

Connection system with tin-plated aluminium busbars from 250 to 4000 A.

Suitable for all connections

Circuit breaker connection and extensionof horizontal busbars tangs.

Circuit breaker connection in the upper zone.

Busbar juncture.Extension of the connection to busbars duct.

Circuit breaker connection to vertical busbars.

82 | Lafer | Smart-Energy

Page 6: Universal aluminium busbar system up to 6300 A · • Anodized aluminium profiles with a nickel contact surface applied. • Linear system with the option to be installed in the cable

Modular circuit breakers connection.

Connection with brass washer.

Rapid connection system frontal/lateral insertionInsulator phase compensators

Phases and neutralidentification. Busbars alignment system.

Very fast installation and reduced use of mounting tools.

AccessoriesComfort close at handsVery fast installation and reduced use of mounting tools.

Rectangular-head screws.

ENG

_06_2017 - studiobrand.it - In order to ensure a continuous improvem

ent of the products, Lafer reserves the right to make m

odifications to the characteristics described (without notice).

Smart-Energy | Lafer | 83