GSEducationalVersion
2014 DOCUMENTATION 1 MAJOR PROJECT HOUSE
N
6,65
0
3,000
1,00
01,
200
9.80
9.60
9.40
9.20
9.00
8.80
8.758.70
9.80 9.80
9.80
9.60
9.40
9.00
8.80
9.20
boundary 23.40m.
boundary 23.40m.
boun
dary
21.
20m
.
boun
dary
21.
20m
.
OUTLINE OF PROPOSED HOUSE
F.F.L. 10 00
proposed deck
landscaped
landscaped
landscapedlandscaped
sealeddriveway
entry
crossing
grass berm
footpath
path
paved service court
council w.w drainand manholeconnection
council sw. drainand manholeconnection
Site Plan 1:100
UNITEC SAMPLE
GSEducationalVersion
2014 DOCUMENTATION 1 MAJOR PROJECT HOUSE
2,86
0
2,60
026
02,
455
2,00
02,
200
300
30° 30°
+10,0001 Ground Floor
+10,0001 Ground Floor
+12,8602 First Floor
+12,8602 First Floor
2,86
0
2,60
026
0
2,20
020
00
300 300
135135
15°15°
+10,0001 Ground Floor
+10,0001 Ground Floor
+12,8602 First Floor
+12,8602 First Floor
Section AA 1:100
Section BB 1:100
UNITEC SAMPLE
GSEducationalVersion
Drawn by:
Student ID:
Stream 3
Scale:
Major Project House 2014Doc1
Layout:
L14
EAST/WEST SECTION
General Notes- No dimensions are to be scaled from this
drawing- Any discrepancies found in this drawing or any
related document must be reported to architectprior to construction
- Contractor must verify all dimensions andlevels on site before construction
- Drawing to be read in conjunction with all othersheets in set
- SED - Specific Engineering Design, refer toengineers drawings
- All construction to comply with NZS3604:2011,all relevant clauses of NZBC and requirementsof local planning authority
D-03A01
D-02A01
135
300
2,10
0
3,42
1
2,55
0
2,86
5
2,45
5
2,10
0
3,98
5
EXTERNAL WALLS: 90x45mm H1.2 wall framing @600crs(H3.1 for wet areas) w/ 180x16mm Jenkin a-lign® bevelback weatherboards on 20x45mm H3.1ventilated cavity battens @ 600crs on ThermakraftCovertek® building wrap and 10mm standard GIBinternal lining w/ R2.2 Pink Batts® wall insulation
TRUSS ROOF AND EAVES: Colorsteel Endura® 0.55mm longrun corrugated steelroofing on Thermakraft Covertek 405 roof underlay on 70x45mm H1.2 purlins @900crs. max spacing on prefabricated Pryda® roof trusses @ 900crs. max. spacingw/ Marley Typhoon uPVC 6100mm2 spouting system and 80mmØ downpipes into T-spreader system on Jenkin Tru-Pine 190x18mm barge board and 190x18mm fasciaw/ Glidevale ventilators in flat eaves w/ James Hardie Silkline soffit lining
MIDFLOOR FRAMING: 20mm particle board (plywoodfor wet areas) on 290x45mm H1.2 floor joists @450crs max spacing with solid blocking at centre line
HIP ROOF: Colorsteel Endura® 0.55mm longruncorrugated steel roofing on Thermakraft Coverup® roofunderlay on 70x45mm H1.2 purlins @ 900crs maxspacing on 2/140x45mm rafters @ 900 crs. notchedback at eaves overhang to 90x45mm fixed to140x45mm stringer with joist hanger and 2 stainlesssteel straps to top plate w/ R2.2 Pink Batts roofinsulation on 70x45mm purlins on the flat @ 900 crs.on 10mm GIB internal lining
INTERNAL WALLS: 90x45mm studs w/ 90x45mmmottomplates, nogs and topplates and 140x35mmstrapping plates w/ nogs @ max 1350mm crs. w/90mm Pink Batts Silencer insulation where indicated
EJ16 EJ17
EJ06 EJ01 EJ04 EJ02
IJ21 IJ16
SED SED
BEDROOM 2 BEDROOM 3LANDING
MASTER BEDROOM KITCHEN DINING LIVING WORKSHOPAND
SINGLE GARAGE
WR WR
Floo
r to
floor
Floo
r to
top
of s
trapp
ing
plat
e
Floo
r to
win
dow
/doo
r/bul
khea
d
Floo
r to
top
of s
trapp
ing
plat
e
Floo
r to
win
dow
/doo
r hea
d
Floo
r to
unde
rsid
e of
stri
nger
Floo
r to
ridge
+10,0001 Ground Floor
+12,8602 First Floor
+15,3153 Roof
D-04A01
D-06A02
CONCRETE SLAB FLOOR: 100mm conc. slab w/ 500E mesh onexport H-grade 40mm thick R1.1 insulation on 250 micron DPM on25mm sand blinding on 150mm compacted hardfill layer with Firth20-series® solid filled block foundation wall with D10 starters @600crs bent over D12 horizontal trim bar 350mm into slab conc.strip footing with 4/D12 bars horizontal with R10 ties @ 600 crs.
CEILING SYSTEM: 10mm GIB Ultraline Plus® ceilinglining on 70x35mm H1.2 battens @ 400crs with R2.2Pink Batts® ceiling insulation
TIMBER SUBFLOOR: 21mm Forte Prefinished woodflooring Ultra on140x45mm H1.2 floor joists @ 450 crs. w/ continues boundary joist forlateral support w/ 90mm R1.4 Pink Batts® insulation and 50mmpolystyrene (fixed w/ 45x35 battens on flat) on 2/190x45mm H3.2 bearerson 125x125mm H5 Senton piles @ 1650 crs. max spacing set inØ540x450mm deep concrete footings (900mm min. depth for anchor piles)
S-02 Long Section East / West 1L03, L04
1:50
Notes
- All timber Radiata Pine SG8 H1.2unless a perimeter joist - H3.2 or asspecified
- All measurements in mm, unlessspecified
Key
EJ - External Joinery IJ - Internal Joinery WR - Wardrobe
UNITEC SAMPLE
GSEducationalVersion
Drawn by:
Student ID:
Stream 3
Scale:
Major Project House 2014Doc1
Layout:
L13
NORTH/SOUTHSECTION
General Notes- No dimensions are to be scaled from this
drawing- Any discrepancies found in this drawing or any
related document must be reported to architectprior to construction
- Contractor must verify all dimensions andlevels on site before construction
- Drawing to be read in conjunction with all othersheets in set
- SED - Specific Engineering Design, refer toengineers drawings
- All construction to comply with NZS3604:2011,all relevant clauses of NZBC and requirementsof local planning authority
Roof Pitch 30°Roof Pitch 30°
D-11A03
+9,900+9,950
300
2,10
0
2,86
0
2,10
02,45
52,
550
3,98
5
2,30
0
1,556
EXTERNAL WALLS: 90x45mm H1.2 wall framing @600crs(H3.1 for wet areas) w/ 180x16mm Jenkin a-lign®bevelback weatherboards on 20x45mm H3.1 ventilatedcavity battens @ 600crs on Thermakraft Covertek®building wrap and 10mm standard GIB internal lining w/R2.2 Pink Batts® wall insulation
CONCRETE SLAB FLOOR: 100mm conc. slab w/ 500E mesh onexport H-grade 40mm thick R1.1 insulation on 250 micron DPM on25mm sand blinding on 150mm compacted hardfill layer with Firth20-series® solid filled block foundation wall with D10 starters @600crs bent over D12 horizontal trim bar 350mm into slab conc.strip footing with 4/D12 bars horizontal with R10 ties @ 600 crs.
STAIR SYSTEM: Prefabricated timber stairs w/179mm riser and 280mm going
TRUSS ROOF AND EAVES: Colorsteel Endura® 0.55mm longruncorrugated steel roofing on Thermakraft Covertek 405 roof underlay on70x45mm H1.2 purlins @ 900crs. max spacing on prefabricated Pryda®roof trusses @ 900crs. max. spacing w/ Marley Typhoon uPVC 6100mm2
spouting system and 80mmØ downpipes into T spreader system on JenkinTru-Pine 190x18mm barge board and 190x18mm fascia w/ Glidevaleventilators in flat eaves w/ James Hardie Silkline soffit lining CEILING SYSTEM: 10mm GIB Ultraline Plus® ceiling
lining on 70x35mm H1.2 battens @ 400crs with R2.2Pink Batts® ceiling insulation
MIDFLOOR FRAMING: 20mm particle board (plywoodfor wet areas) on 290x45mm H1.2 floor joists @450crs max spacing with solid blocking at centre line
MONO PITCH SKILLION ROOF: Colorsteel Endura®0.55mm longrun corrugated steel roofing onThermakraft Coverup® roof underlay on 70x45mmH1.2 purlins @ 900crs max spacing on 90x45mm H1.2rafters on 290x90mm H1.2 underpurlins
TIMBER SUBFLOOR: 21mm Forte Prefinished woodflooring Ultra on140x45mm H1.2 floor joists @ 450 crs. w/ continues boundary joist forlateral support w/ 90mm R1.4 Pink Batts® insulation and 50mmpolystyrene (fixed w/ 45x35 battens on flat) on 2/190x45mm H3.2 bearerson 125x125mm H5 Senton piles @ 1650 crs. max spacing set inØ540x450mm deep concrete footings (900mm min. depth for anchor piles)
TIMBER DECK AND STAIRS: 130x32mm deckingtimber on 140x45 H3.2 deck joists @ 600crs. on2/140x45mm H3.2 bearers/stringer on 125x125 H5Senton piles @ 1650 crs. max spacing set inØ290x450mm deep concr. footings (460Ø underextended roof posts)w/H3.2 Timber stairs w/180mm rise - 280mm going
ENTRY COLUMN CLADDING: 350x350mm Murosbrick panel
ENTRY SLAB: 100mm thick 17.5 MPa concr. edge tobe thickened 200wx450d w/ D12 starters into mainslab @ 600crs (100mm into main slab, 400mm intoentry slab) and extra reinforcement under columns w/1/D12 horizontal bottom rod and 2/D12 vertical starters
INTERNAL WALLS: 90x45mm studs w/ 90x45mmmottomplates, nogs and topplates and 140x35mmstrapping plates w/ nogs @ max 1350mm crs. w/90mm Pink Batts Silencer insulation where indicated
KITCHEN / DINING / LIVING
BATHROOM LANDING
ENTRYSTAIRS
ST.
LOBBYIJ17 IJ15
Floo
r to
floor
Floo
r to
top
of s
trapp
ing
plat
e
Floo
r to
win
dow
/doo
r/bul
khea
d
Floo
r to
top
of s
trapp
ing
plat
e
Floo
r to
win
dow
/doo
r hea
d
Floo
r to
ridge
Ent
ry c
olum
n cl
addi
ng h
eigh
t
+10,0001 Ground Floor
+12,8602 First Floor
+15,3153 Roof
D-05A01
D-10A03
S-01 Cross Section North / SouthL03, L04
1:50
Notes
- All timber Radiata Pine SG8 H1.2unless a perimeter joist - H3.2 or asspecified
- All measurements in mm, unlessspecified
Key
EJ - External Joinery IJ - Internal Joinery
UNITEC SAMPLE
GSEducationalVersion
Drawn by:
Student ID:
Stream 3
Scale:
Major Project House 2014Doc1
Layout:
L12
SOUTH & WESTELEVATION
General Notes- No dimensions are to be scaled from this
drawing- Any discrepancies found in this drawing or any
related document must be reported to architectprior to construction
- Contractor must verify all dimensions andlevels on site before construction
- Drawing to be read in conjunction with all othersheets in set
- SED - Specific Engineering Design, refer toengineers drawings
- All construction to comply with NZS3604:2011,all relevant clauses of NZBC and requirementsof local planning authority