BALDUR Nordeon Specifications Baldur UNIQUELY DESIGNED, FLEXIBLE AND EFFICIENT LIGHT LINE SYSTEM Unique combination of both accent and ambient lighting in one design, great aesthetic fit between the light line and the spots: the drivers for the spots are 'hidden' inside the trunk Easy to adapt the configuration of the light line when a changing layout of the environment requires this: Flexibility to place general lighting units, sensors and lighting controls, emergency lighting units and blind covers at specific positions The combination of trunk lengths up to 5,058 mm and the Nordeon ClickFast system enables fast and easy installation Electrical units for three circuit lighting track systems (3C systems) and recessed version available
8
Embed
UNIQUELY DESIGNED, FLEXIBLE AND EFFICIENT LIGHT LINE ... · BALDUR Nordeon Specifications Baldur UNIQUELY DESIGNED, FLEXIBLE AND EFFICIENT LIGHT LINE SYSTEM Unique combination of
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
BALDUR
Nordeon Specifications Baldur
UNIQUELY DESIGNED, FLEXIBLE AND EFFICIENT LIGHT LINE SYSTEM
Unique combination of both accent and ambient lighting in one design, great aesthetic fit between the light line and the spots: the drivers for the spots are 'hidden' inside the trunk
Easy to adapt the configuration of the light line when a changing layout of the environment requires this:
Flexibility to place general lighting units, sensors and lighting controls, emergency lighting units and blind covers at specific positions
The combination of trunk lengths up to 5,058 mm and the Nordeon ClickFast system enables fast and easy installation
Electrical units for three circuit lighting track systems (3C systems) and recessed version available
3
* half-peak** for a homogenous light emission
1. Connect trunking sections
3. Click lighting unit into trunking line
2. Select electrical phase at the unit
4. All units can be removed and easlily placed at other positions when desired
NB Narrow beam for high halls and high rack areas (32°)*
MB Medium beam for general lighting in open areas best glare control, UGR 19, (74°)* (MB-O version, slightly opalised**)
System power 20-23.5 W 25.5-30 W 42-49 W 58-69 W 67-80 W 30-35 W 38.5-44.5 W 63-73.5 W 87-104 W 99-120 W
Colour temperature 3000 K / 4000 K / 6500 K
CRI Ra > 80; (> 90 on request)
Optic / narrow , medium , wide , ultra- wide, double asymmetrical and asymmetrical light beams, moreover opal light distribution optic and opal with indirect share
Lifetime 70.000 h (L80B10) 50.000 h (L80) 70.000 h (L80B10) 50.000 h (L80)
Operating temp. -20 °C to 35 °C -20 °C to 35 °C -20 °C to 35 °C -20 °C to 35 °C (-45 °C on request) (-45 °C on request)
Weight approx. 3.2 kg per meter (including trunking and accessories)
Additional EL3, daylight and presence sensor, blindcover (metal or plastic), 3C rails, recessed frame, Skadi on Baldur
Driver STD standard or DALI dimming, DC suitable
* preliminary values
GENERAL SPECIFICATIONS
BALDUR
Nordeon Specifications Baldur
70.000 hL80/B10
IP40
5
63
81,2
1124
1686
Different lengths of the trunking sections
Baldur units
Cross section
DIMENSIONAL DRAWING
All measures in millimeter
System 1124 mm (4 FT) 1686 mm (6 FT)
Throughwiring 5 x 2.5 mm², 7 x 2.5 mm², 9 x 2.5 mm², 11 x 2.5 mm²
Position distance between 1 FT(281 mm) 1 FT(281 mm) electrical contacts 2 FT (562 mm) 2 FT (562 mm) 4 FT (1124 mm) 6 FT (1686 mm)
Length of trunking sections 1124 mm (4 FT) 1686 mm (6 FT) 2248 mm (2 x 4 FT) 3372 mm (2 x 6 FT) 3372 mm (3 x 4 FT) 5058 mm (3 x 6 FT), new 4496 mm (4 x 4 FT)
Material / cover white (RAL9016), black (RAL9005) or silver (RAL9006) coated steel
TRUNKING SECTIONS RANGE
mounting brackets
trunking
electrical unit
electrical unit with 3C track
electrical unit with sensor
Skadi 3C spotlight
1124, 1686, 2248, 3372 and 5058
Nordeon Specifications Baldur
BALDUR CONFIGURATION MATRIX
Length of Light units Trunking sections Mounting Coupling pieces Power sets light line 1686 mm brackets between incl. two (meter) 1686 mm 3372 mm 5058 mm trunking end caps
1.69 1 1 2 0 1
3.37 2 1 2 0 1
5.06 3 1 2 0 1
6.74 4 2 3 1 1
8.43 5 1 1 3 1 1
10.12 6 2 4 1 1
11.8 7 2 1 4 2 1
13.49 8 1 2 5 2 1
15.17 9 3 6 2 1
16.86 10 2 2 6 3 1
18.55 11 1 3 7 3 1
20.23 12 4 7 3 1
21.92 13 2 3 8 4 1
23.60 14 1 4 8 4 1
25.29 15 5 9 4 1
26.98 16 2 4 9 5 1
28.66 17 1 5 10 5 1
30.35 18 6 11 5 1
Length of Light units Trunking sections Mounting Coupling pieces Power sets light line 1124 mm brackets between incl. two (meter) 1124 mm 2248 mm 3372 mm 4496 mm trunking end caps
1.12 1 1 2 0 1
2.25 2 1 2 0 1
3.37 3 1 2 0 1
4.5 4 1 2 0 1
5.62 5 1 1 2 1 1
6.74 6 1 1 3 1 1
7.87 7 1 1 3 1 1
8.99 8 2 3 1 1
10.12 9 3 4 2 1
11.24 10 1 2 4 2 1
12.36 11 1 2 5 2 1
13.49 12 3 5 2 1
14.61 13 1 1 2 5 3 1
15.74 14 1 3 6 3 1
16.86 15 1 3 6 3 1
17.98 16 4 6 3 1
19.11 17 3 2 7 4 1
20.23 18 1 4 7 4 1
SYSTEM LENGTH 1686 MM (6 FT)
SYSTEM LENGTH 1124 MM (4 FT)
7
NARROW BEAM (NB) FOR HIGH HALLS AND HIGH RACK AREAS (32°)
Installation height 6-12 m
Imax/2 (half peak) / UGR4h8h (glare control) 2 x 16° (32°), UGR22 (for 6000 lm at 1686 mm)
System Luminous Luminous Colour CRI (Ra) Order number Type power (W) flux (lm) efficacy (lm/W) temperature (K)