UNIMASTER DUST COLLECTOR WITH DUST CONTAINERUMA 153 illustrated.
Suitable for inside locations. *Secondary filter and absolute
filter not available for UMA 72 dust collector.
SIDE ELEVATION FRONT ELEVATION
Publication 2724E (GB) 0906
Data Sheet
Donaldson reserve the right to alter design without notice.
Freedom from patent restrictions must not be assumed.
Unimaster Dust CollectorsSeries UMA 70-250
Fan chamber
Contaminatedair inlet(may be fittedeither side orat rear)
380required for cleanermotor cover removal
A
Lifting bracket(removable)
Terminal box
Cleaner motor
Filter chamber
Quick-releasesealer gear
Dust container
Cleaned airoutlet
drequired formaintenance
Joint line
102
e
C
B
fto centre ofinlet spigot
Acoustic diffuser(may be fitted withoptional secondary
orabsolute filter)*
230minimumclearance
SPECIFICATIONSInlet spigot NetFiltration DIMENSIONS in mm Motor
DustType (inside dia.) Fan weightarea A B C d e f rating
containermm (approx.)
UMA 72 6.23 m2 575 575 2029 600 729 648 ∅ 101 G1 0.75 kW 55
litre 203 kg
G1 0.75 kW 295 kgUMA 103 9.29 m2 765 575 2535 800 883 685 ∅ 203
80 litreK3 1.50 kW 300 kg
G1 0.75 kW 333 kgK3 1.50 kW 338 kg
UMA 153 13.94 m2 765 765 2591 800 883 685 ∅ 203 K5 2.20 kW 80
litre 353 kgK7 3.00 kW 378 kgG8 5.50 kW 393 kg
G1 0.75 kW 445 kgK3 1.50 kW 450 kg
UMA 253 22.67 m2 1146 765 2942 1150 1099 883 ∅ 254 K5 2.20 kW 80
litre 465 kgK7 3.00 kW 490 kgG8 5.50 kW 505 kg
Donaldson®Torit®DCE®
-
2
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
SPECIFICATIONSNetFiltration DIMENSIONS in mm MotorType Fan
weightarea A B C d rating (approx.)
UMA 70H 6.23 m2 575 575 1338 600 G1 0.75 kW 170 kg
G1 0.75 kW 235 kgUMA 100H 9.29 m2 765 575 1652 800 K3 1.50 kW
240 kg
G1 0.75 kW 270 kgK3 1.50 kW 275 kg
UMA 150H 13.94 m2 765 765 1708 800 K5 2.20 kW 290 kgK7 3.00 kW
315 kgG8 5.50 kW 330 kg
G1 0.75 kW 355 kgK3 1.50 kW 360 kg
UMA 250H 22.67 m2 1146 765 1843 1150 K5 2.20 kW 375 kgK7 3.00 kW
400 kgG8 5.50 kW 415 kg
UNIMASTER HOPPER TYPE DUST COLLECTORUMA 150H illustrated.
Suitable for inside locations. *Secondary filter and absolute
filter not available for UMA 70H dust collector.
SIDE ELEVATION FRONT ELEVATION
Fan chamber
380required for cleanermotor cover removal
A
Lifting bracket(removable)
Terminal box
Cleaner motor
Filter chamber
Cleaned airoutlet
drequired formaintenance
102
C
B
Acoustic diffuser(may be fitted withoptional secondary
orabsolute filter)*
230minimumclearance
S e a t i n g l e v e l
ApproxSize net weight
55 litre 5 kg80 litre 6 kg
A reasonable total load forremoval by hand would be 25 kg
55 litre(2 cu.ft.)
DUST CONTAINERTypical dust densities
Density withDust 50% voidageSander 0.13 kg/litreGraphite 0.80
kg/litreSand 1.33 kg/litreIron 3.58 kg/litreSteel 3.72 kg/litre
80 litre(3 cu.ft.)
Donaldson®Torit®DCE®
-
3
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
380required for cleanermotor cover removal
A
Lifting bracket(removable)
Cleaned airoutlet
drequired formaintenance
90
B230
minimumclearance
CCleaner motorFilter chamber
S e a t i n g l e v e l
SPECIFICATIONSNetFiltration DIMENSIONS in mmType weightarea A B
C d (approx.)
UMA 70V 6.23 m2 575 575 678 560 93 kg
UMA 100V 9.29 m2 765 575 678 560 114 kg
UMA 150V 13.94 m2 765 765 735 760 135 kg
UMA 250V 22.67 m2 1146 765 735 760 175 kg
UNIMASTER VENTING TYPE DUST COLLECTORUMA 150V illustrated.
Suitable for inside locations and outside when fitted with optional
weather cowl.
SIDE ELEVATION FRONT ELEVATION
SPECIFICATIONSInlet spigot NetFiltration DIMENSIONS in mm
DustType (inside dia.) weightarea A B C d e f containermm
(approx.)
UMA 72V 6.23 m2 575 575 1369 560 729 648 ∅ 101 55 litre 126
kg
UMA 103V 9.29 m2 765 575 1485 560 845 685 ∅ 203 80 litre 174
kg
UMA 153V 13.94 m2 765 765 1542 760 845 685 ∅ 203 80 litre 199
kg
UMA 253V 22.67 m2 1146 765 1758 760 1061 883 ∅ 254 80 litre 265
kg
Contaminatedair inlet(may be fittedeither side orat rear)
380required for cleanermotor cover removal
A
Lifting bracket(removable)
Cleaner motorFilter chamber
Quick-releasesealer gear
Dust container
Cleaned airoutlet
drequired formaintenance
Joint line
90
e
C
B
fto centre ofinlet spigot
230minimumclearance
UNIMASTER VENTING TYPE DUST COLLECTOR WITH DUST CONTAINERUMA
153V illustrated. Suitable for inside locations and outside when
fitted with optional weather cowl.
SIDE ELEVATION FRONT ELEVATION
Donaldson®Torit®DCE®
Donaldson®Torit®DCE®
-
4
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
SPECIFICATIONSNetFiltration DIMENSIONS in mm MotorType Fan
weightarea A B C d e rating (approx.)
UMA 100STU 9.29 m2 765 575 2706 800 1054 K3 1.50 kW 313 kg
UMA 150STU 13.94 m2 765 765 2762 800 1054 K3 1.50 kW 368 kg
UMA 250STU 22.67 m2 1146 765 2897 1150 1054 K3 1.50 kW 553
kg
Fan chamber
380required for cleanermotor cover removal
A
Lifting bracket(removable)
Terminal box
Cleaner motor
Filter chamber
Cleaned airoutlet
drequired formaintenance
102
C
B
Acoustic diffuser(may be fitted withoptional secondary
orabsolute filter)
230minimumclearance
S e a t i n g l e v e l
Alternative insertwith swing doorfor sack tipping unitsfitted
with optionalexplosion relief panelsOpening:585 wide x 665 deep
Quick-release hatch(removed when tipping)Standard opening onall
models:680 wide x 700 deep
Joint line
e
UNIMASTER SACK TIPPING UNITUMA 150STU illustrated. Suitable for
inside locations.
SIDE ELEVATION FRONT ELEVATION
DESIGN LIMITS (standard equipment)
Temperature range: −10° to +60°C
Pressure limits: Collectors with fan: as fan performance curves
from shut-off to operating pressureVenting type collectors: −300
mmW.G. to +250 mm W.G.
Dimension tolerances: ±3 mm on main dimensions; ±2 mm on detail
dimensions
Equipment suitable for use in a potentially explosive atmosphere
(Directive 94/9/EC)satisfying the requirements for group II
category 2D and 3D T135°C is available
Donaldson®Torit®DCE®
-
5
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
193=
37
= 193= =
284= =
193
=
=
284
=
=
284
=
=
120
120
37
130
46.5
46.5
13046.546.5
111.5 111.5
37120
37120
37
120
120
37
UMA 70V UMA 100V and 150V
UMA 250V
CLEANED AIR OUTLET DETAILS FOR VENTING TYPE COLLECTORSAll holes
∅4 mm
DIMENSIONS in mmType A B c
UMA 70 225 225 116
UMA 100 295 250 116
UMA 150 320 320 116
UMA 250 340 340 403
A
B
40
CLEANED AIR OUTLET DETAILSUMA 150 illustrated
c
-
6
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
UMA 70H and 70V
APERTURE AND MOUNTING FLANGE DETAILS FOR HOPPER AND VENTING TYPE
COLLECTORSAll holes ∅12 mm for M10 bolts
205200 8520520020585
85
205
225
205
8535 1145
1215
3535
765 835
35205225 8520585
85
205
225
205
8535 35
35
765 835
35
765
835
205225 8520585
40
180
175
180
4035 35
35
575 645
35
765
835
180175 4018040
40
180
175
180
4035 35
35
575 645
35
575
645
UMA 100H and 100V
UMA 150H and 150V UMA 250H and 250V
-
7
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
285 285 125125
190
190
125
125
575 675
50
50765
865
5050
285 285 125125
285
285
125
125
765 865
50
50765
865
5050
475 475 125125
285
285
125
125
765 865
50
5050
50 1145
1245
UMA 100STU UMA 150STU
UMA 250STU
APERTURE AND MOUNTING FLANGE DETAILS FOR SACK TIPPING UNITSAll
holes ∅12 mm for M10 bolts
Safety bars(30 x 30 x 5 RSA)welded at equalintervals betweenside
members
-
8
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
0 500 1000 1500 2000 2500 3000 3500 4000
AIR VOLUME (m3/h)
400
350
300
250
200
150
100
50STATICPRESSUREATFANINLET(mmW.G.)
UNIT PERFORMANCE CURVES
FAN SELECTION
These curves indicate static pressure available at fan inlet for
a given volume when fitted inside aUnimaster dust collector.
To select the most suitable fan for a given application:
1 Determine the air volume, in m3/h, needed to entrain the
dust.
2 Read off the unit resistance, in mm W.G., at air volume
required.
3 Assess pressure drop over filter bags prior to cleaning,
usually 50 to 100 mm W.G.
4 Estimate pressure drop through connected system − i.e. between
point of entrainment and collector inlet.5 The sum of 2, 3 and 4 =
W.G. required.6 Consult graph for fan performances available.
Sack Tipping Units have K3 (1.5 kW) fans with modified outlet to
ensure adequate face velocities at the tipping hatchunder normal
operating conditions. Typically, the exhaust rate for the UMA
250STU is 1275 m3/h (750 cfm).
K7
K5K
3
G1
UNITRES
ISTANCE
CURVE
G8
ELECTRICALREQUIREMENTS
UCS Controller
Voltage input: 220-240V, Single Phase, 50Hz (for collectors with
G1 or K3 fans only)218-242V / 380-420V, Three Phase, 50Hz250-277V /
440-480V, Three Phase, 60Hz
or to suit local voltage
-
9
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
NOISE LEVELS
Machinery noise levels are an important consideration in the
design and selection of new equipment.Several EC Directives and
National Laws/Regulations adopting these directives make reference
to airborne noise emissions.
Actions that employers are required to comply with if employees
are subjected to a daily personal noiseexposure Lep,d of 85 dB(A)
or more are also specified.
All Unimaster dust collectors, when fitted with an acoustic
diffuser, secondary filter or absolute filter,operating an 8 hour
shift, are below this action limit.
OPTIONAL WEATHER COWLUMA 150V illustrated
SIDE ELEVATION(Detail of cleaned air outlet withweather cowl and
lid removed)
FRONT ELEVATIONSIDE ELEVATION
A150
minimumclearance
194Bc= =
109 175
29
SPECIFICATIONSNetDIMENSIONS in mmType weightA B c (approx.)
UMA 70V 585 584 473 12 kg
UMA 100V 775 584 473 12 kg
UMA 150V 775 774 697 19 kg
UMA 250V 1156 774 697 19 kg
WEIGHTED SOUND PRESSURE LEVELS
All readings were taken in normal industrial areas, i.e.
semi-reverberant surroundings, with local equipment
silent.Measurements were taken at maximum air flow conditions at
1.0 metre radius from the equipment housing
and 1.6 metres above base level, using a precision sound level
meter and octave filter.
G1 K3 K5 K7 G8
With acoustic diffuser 65 dB(A) 67 dB(A) 68 dB(A) 69 dB(A)� 72
dB(A)With secondary filter * 67 dB(A) 68 dB(A) 69 dB(A) 72
dB(A)With absolute filter * 67 dB(A) 68 dB(A) 69 dB(A) 72 dB(A)
Noise levels of installed equipment may vary due to site
conditions.*Secondary and absolute filter not supplied with G1 fan.
�Measured data.
-
10
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
SIDE ELEVATIONREAR ELEVATION
POSITION OF OPTIONAL EXPLOSION RELIEF FLANGEUMA 153
illustrated
80
SIDE ELEVATIONREAR ELEVATION
POSITIONOFOPTIONALEXPLOSIONRELIEFFLANGESFORSACKTIPPINGUNITSUMA
150STU illustrated
If vent ducts are not connected to the explosion relief flanges,
then a minimum clearance of 500 mm should be madeto the rear of the
collector to ensure efficient operation of the explosion venting
process. Consideration should be given to the
local surrounding area in regards to the pressure and flame
effects.
80
100
152 (UMA 100)209 (UMA 150)143 (UMA 250)
548 (UMA 100 and 150)614 (UMA 250)
468 (UMA 100 and 150)402 (UMA 250)
Joint line
UMA type: 72 103 153 253 70H 100H 150H 250H 70V 100V 150V 250V
72V 103V 153V 253V
Dimension A in mm: 76 114 171 105 114 114 171 105 114 114 171
105 76 76 133 67
A
If a vent duct is not connected to the explosion relief flange,
then a minimum clearance of 500 mm should be madeto the rear of the
collector to ensure efficient operation of the explosion venting
process. Consideration should be given to the
local surrounding area in regards to the pressure and flame
effects.
-
11
Data Sheet
Unimaster Dust Collectors Series UMA 70-250
548468
40
4040452
532
4044
44
20
20
51 513 pitches @ 130 mm
3 pitches@ 140 mm
74 744 pitches @ 130 mm
40628
708
4044
44
20
3 pitches@ 140 mm 548468
40
40
59.5 59.57 pitches @ 135 mm
614534
40
40
20
20
27
27
20
4 pitches@ 130 mm
401024
1104
40
UMA 70 UMA 100 and 150
UMA 250
OPTIONAL EXPLOSION RELIEF FLANGE MOUNTING DETAILSAll vertical
holes drilled ∅10 mm for M8 bolts. All horizontal holes threaded to
accept M8 bolts.
-
Humberstone LaneThurmastonLeicester LE4 8HPEngland
Tel +44 (0)116 269 6161Fax +44 (0)116 269 3028
Email: [email protected]
www.donaldson.com
Research Park Zone 1Interleuvenlaan 1B-3001 Leuven
(Heverlee)Belgium
Tel +32 (0)16 383 970Fax +32 (0)16 383 938
Email: [email protected]