UL Korea, Ltd A not-for-profit organization dedicated 33 rd FL, Gangnam Finance Center, 737 to public safety and committed to Yeoksam-dong, Gangnam-gu, Seoul quality service for over 100 years 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Underwriters Laboratories Inc. www.ul.com/emc www.ulk.co.kr Project: 11CA49640 File: MC16807 Report: 11CA49640-CE-EMC Date: October 28, 2011 Model: XT DUAL CE-R&TTE Directive Electromagnetic Compatibility Test Report For Satellite GSM Dual Phone Asia Pacific Satellite communications Inc. 9FL, Lotte IT Castle 2-Dong, #550-1,Gasan-Dong, GeumCheon-Gu, Seoul, Korea, 153-768 Copyright 2005 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Only those products bearing the UL Mark should be considered as being covered by UL.
72
Embed
Underwriters Laboratories Inc. - ITU: Committed to … Type: Satellite GSM Dual Phone Model Number: XT DUAL Trademark Product standards: ETSI EN 301 489-1 V1.8.1_ EMC standard for
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
UL Korea, Ltd A not-for-profit organization dedicated 33rd FL, Gangnam Finance Center, 737 to public safety and committed to Yeoksam-dong, Gangnam-gu, Seoul quality service for over 100 years 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405
Underwriters Laboratories Inc.
www.ul.com/emc www.ulk.co.kr
Project: 11CA49640
File: MC16807
Report: 11CA49640-CE-EMC
Date: October 28, 2011
Model: XT DUAL
CE-R&TTE Directive Electromagnetic Compatibility Test Report
For
Satellite GSM Dual Phone
Asia Pacific Satellite communications Inc.
9FL, Lotte IT Castle 2-Dong, #550-1,Gasan-Dong, GeumCheon-Gu, Seoul, Korea, 153-768
Copyright 2005 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety.
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 2 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Summary of Test Results:
The following tests were performed on a sample submitted for evaluation of compliance with ETSI EN 301 489-1 V1.8.1, ETSI EN 301 489-7 V1.3.1, EN 301 489-17 V1.3.2 and EN 301 489-20 V1.2.1.
Test #
Test Name Test Requirement/Specification
Compliant Not Compliant See Remark
1 Conducted emissions on Mains power port X - -
2 Radiated emission X - -
3 Harmonic current emission - - 1)
4 Voltage fluctuation and flicker X - -
5 Electrostatic Discharges (ESD) X - -
6 RF electromagnetic field X - -
7 Fast transients immunity X - -
8 Surges immunity X - -
9 RF conducted continuous immunity X - -
10 Power frequency magnetic field immunity - - 1)
11 Voltage dips and short interruption X - -
Remarks: 1) Not applicable to this EUT. 2) Modifications to EUT required for compliance: None. 3) Purpose of Application : This application is to verify the compliance to the essential requirements of the harmonised standards applied to the original assessment due to the minor change of components. Manufacturer has declared the details of change and provided as the reference of this assessment. The change details is shown in the separate declaration statement.
Conclusion: The tests listed in the Summary of Testing section of this report have been performed as a witness testing and the results recorded by UL Korea Ltd. in accordance with the procedures stated in each test requirement and specification. The test list was determined by the Applicant as being applicable to the Equipment Under Test. As a result, the subject product has been verified to comply or not comply as noted in the Summary of Testing with each test specification. The test results relate only to the items tested. The equipment under test has
Met the technical requirements Not met the technical requirements
Tested by Jeawoon Choi, Senior Project Engineer
Reviewed by Kyungyong Kim, WiSE Manager
Conformity Assessment Services - 3014ASEO Conformity Assessment Services - 3014ASEO UL Korea Ltd. UL Korea Ltd. October 28, 2008 October 28, 2008
Project Number: 11CA49640 File Number MC16807 Page 3 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Test Report Details Tests Performed By: UL Korea Ltd. 33rd FL. GFC Bldg. 737 Yeoksam-dong,
Kangnam-ku, Seoul, 135-984, Korea Test Site: DigitalEMC Co., Ltd. 683-3, Yubang-Dong, Cheoin-Gu, Yongin-Si, Gyeonggi-Do, 449-080, Korea The test facility was deemed to have the environment and capabilities necessary to
perform the tests included in the test package. Applicant: Asia Pacific Satellite communications Inc. 9FL, Lotte IT Castle 2-Dong, #550-1, Gasan-Dong, GeumCheon-Gu, Seoul, Korea,
153-768
Applicant Contact: Young-Soo, Lee / Junior Engineer – R&D Center Phone: +82 2-2026-7788 E-mail: [email protected]
Manufacturer: Asia Pacific Satellite communications Inc. 9FL, Lotte IT Castle 2-Dong, #550-1, Gasan-Dong, GeumCheon-Gu, Seoul, Korea,
153-768
Product Type: Satellite GSM Dual Phone
Model Number: XT DUAL
Trademark
Product standards: ETSI EN 301 489-1 V1.8.1_ EMC standard for radio equipment and services; Part 1: Common technical requirements
ETSI EN 301 489-7 V1.3.1 _Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems ETSI EN 301 489-17 V1.3.2_Part 17: Specific conditions for 2,4 GHz wideband transmission systems, 5 GHz high performance RLAN equipment and 5,8 GHz Broadband Data Transmitting Systems ETSI EN 301 489-20 V1.2.1_Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS)
Sample Serial Number: N/A
Sample Receive Date: October 12, 2011 Testing Start Date: October 12, 2011 Date Testing Complete: October 24, 2011 Test Report Date: Overall Results: Compliant
UL Korea Ltd. reports apply only to the specific samples tested under stated test conditions. All samples tested were in good operating condition throughout the entire test program. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. UL Korea Ltd. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from UL Korea Ltd. issued reports.
Project Number: 11CA49640 File Number MC16807 Page 4 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Report Directory 1. GENERAL PRODUCT DESCRIPTION ________________________________________________________ 5
1.1 REPORT REVISION HISTORY ________________________________________________________ 5
3.8 RADIO FREQUENCY, COMMON MODE ______________________________________________ 60
3.9 VOLTAGE DIPS AND INTERRUPTIONS ______________________________________________ 63
APPENDIX A. PRODUCT PHOTOS_EXTERNAL ______________________________________________ 65
APPENDIX B. PRODUCT PHOTOS_INTERNAL _______________________________________________ 70
APPENDIX C - ACCREDITATIONS AND AUTHORIZATIONS ____ ______________________________ 71
APPENDIX D - MEASUREMENT UNCERTAINTIES ___________________________________________ 72
Project Number: 11CA49640 File Number MC16807 Page 5 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
1. GENERAL PRODUCT DESCRIPTION
1.1 Report Revision History
Revision Date Description Revised By Revision reviewed By
None Original - -
1.2 Equipment Description
Description
Thuraya XT DUAL is an advanced satellite phone using cutting edge technology. Its superiority is reflected in having three integrated technologies in one handset: satellite (SAT), GSM and GPS offering you an unmatched combination of quality and performance. Thuraya XT DUAL is a tri-band phone that allows operations on three different GSM networks: 900, 1800, 1900 MHz offering highest flexibility. In order to establish communication on SAT mode, there are a few points to consider: - The antenna should be pulled out to make or receive SAT calls. - While observing the indicator for SAT signal strength, move your phone to achieve the best connection quality. - SAT communication requires clear space without obstructions such as buildings, trees or mountains. - Try to direct the antenna of the Thuraya XT DUAL towards a Thuraya satellite if the signal strength is not sufficient.
1.3 Equipment (EUT) Configuration
Equipment type Manufacturer Model
Satellite GSM Dual Phone Asia Pacific Satellite communications Inc. XT DUAL
Ear Set I-sound HC-MYD-APS001
Travel Charger Ktec KSAS0100500200D5
Note: All the following EUT information has been provided by the applicant.
1.4 Technical descriptions and documents:
No. Document Title and Description
1 User’s manual
Note: The manufacturer provided the following document.
Project Number: 11CA49640 File Number MC16807 Page 6 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
1.5 Technical Specification:
SAT Mode
Item Specification Comment
Transmitter frequency range(s) 1626.5~1660.5 MHz -
Channel Bandwidth 31.25 KHz -
Receiver frequency range(s) 1525~1559 MHz -
Transmitter power Max 2 W Typical 1.8 W
Radiated power (EIRP) Max 7 dBW Min 5.0 dBW
Intermediate frequency 246MHz Level -20 dBm
Frequency Accuracy Uncorrected: < ± 5ppm Corrected: < ± 0.006ppm
Kind of Baseband signal Voice / circuit data / packet data/ fax -
Kind of modulation (s) π/4 - CQPSK -
Data rate(s) Tx: 2.4Kbps /4.8Kbps/ 9.6Kbps /14.4Kbps
Rx2.4Kbps /4.8Kbps/ 9.6Kbps /60Kbps
FEC Convolution (1/2, 1/3, 1/4,1/5) -
Power supply (Battery Voltage) Typ. 3.7Vdc -
Note: All the technical data described above were provided by the manufacturer.
GSM Mode
Parameter / Frequency BAND GSM900 DCS1800
Transmitter frequency range(MHz) 880~915 1710 ~1785
Channel Spacing(kHz) 200 200
Receiver frequency range(MHz) 925 ~ 960 1805 ~ 1880
Transmitter power(dBm, Max) 33 30
Frequency Accuracy(Hz) +/-90 +/-180
Timeslot Period(us) 3.692 3.692
Kind of modulation (s) GMSK GMSK
Modulation Data Rate(kbit/s) 270.833 270.833
Frame period(ms) 4.615 4.615
Data rate(s) CSD RATE:2.4/4.8/9.6/14.4Kbps GPRS downlink max 85.6kbps GPRS uplink max 42.8kbps
CSD RATE:2.4/4.8/9.6/14.4Kbps GPRS downlink max 85.6kbps GPRS uplink max 42.8kbps
Time slot duration(us) 577 577
Power supply (Battery Voltage) Typ. 3.7Vdc
Project Number: 11CA49640 File Number MC16807 Page 7 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Bluetooth Mode
Item Specification
Carrier Frequency 2400MHz to 2483.5MHz (USA, Europe)
Modulation Method GFSK, 1Mbps, 0.5BT Gaussian
Maximum Data Rate Asymmtric: 723.2kbps/57.6kbps Symmetric: 433.9kbps/433.9kbps
Transmission Power Typ 1.0 dBm
Hopping 1600hops/sec, 1MHz channel space
Rx. Sensitivity (BER<0.1%) Typ. -83.0 dBm
Output Interface AUDIO, SPI, UART, PCM, USB
Baseband Crystal OSC 26MHz
Compliant Bluetooth Specification v1.1
Built in Memory Flash memory (4Mbit)
BC02 Bluetooth module Antenna Specifications
Frequency Range 2.4 ~2.485 GHz
VSWR 2.5 : 1 max.
Gain Avg. -3 dBi min.
Polarization Linear
Azimuth Beam Pattern Omni-directional
Impedance Nominal 50 Ω
Note: All the technical data described above were provided by the manufacturer.
Project Number: 11CA49640 File Number MC16807 Page 8 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
1.6 Equipment Marking Plate:
2. TEST CONDITION
2.1 Equipment Used During Test:
Use* Product Type Manufacturer Model Comments
EUT Satellite GSM Dual Phone Asia Pacific Satellite
communications Inc. XT DUAL EUT
EUT Ear Set I-sound HC-MYD-APS001 EUT
EUT Travel Charger Ktec KSAS0100500200D5 EUT
SIM Universal Radio
Communication Tester R&S CMU200 -
SIM SAT TEST NATIONAL INSTRUMENT SAT TEST -
SIM BLUETOOTH TESCOM TC-3000B
AE Notebook LG ELECTRONICS INC. LGR51 -
Note: Use = EUT - Equipment Under Test, AE - Auxiliary/Associated Equipment. SIM - Simulator (Not Subjected to Test)
Project Number: 11CA49640 File Number MC16807 Page 9 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
2.2 Input/Output Ports:
Port
# Name Type*
Cable Max. >3m Shielded Comments
1 Enclosure - - - -
2 DC Input DC 1.8 m Shielded -
3 USB Port I/O 1.5 m Shielded -
4 Ear set port I/O 1.2 m Unshielded -
Note 1: All the interface cables and Power Cable have been provided by the manufacturer Note 2: *AC = AC Power Port DC = DC Power Port N/E = Non-Electrical I/O = Signal Input or Output Port (Not Involved in Process Control) TP = Telecommunication Ports
2.3 Power Interface:
Mode #
Voltage (V)
Current (A)
Power (W)
Frequency (DC/AC-Hz)
Comments
Rated 100-240Vac 0.4 A 10 W AC 50-60Hz -
1 230 - - AC 50Hz -
2.4 EUT Internal Operating Frequencies:
Frequency (MHz) Description Frequency (MHz) Description
12 MHz Main Clock frequency 13 MHz Satellite frequency
2.5 EUT Operation Modes:
Mode # Description
1 GSM 900 Calling Mode While the charging adaptor and ear set were connected to the EUT, a communication link was set up with base station simulator.
2 GSM 900 Idle Mode GSM 900 Mode was set and keep stand-by status
3 BLUETOOTH Mode While the charging adaptor was connected to the EUT, a communication links were set up with base station simulator .
4 SAT Mode While the charging adaptor was connected to the EUT, a communication links were set up with base station simulator and Laptop PC .
Note : GSM 1900 mode of operation was not included in the test plan based on the engineering judgement by the manufacturer. The EMC performance for GSM 900 mode operation can be enough to presumption of conformity of this equipment.
Project Number: 11CA49640 File Number MC16807 Page 10 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
2.6 Test Configuration:
Mode #
Communication link Mode
1
2
Note: Mode 1: GSM/BT communication link, Mode 2 : Satellite communication link
EUT
AC/DC Adapter
Communication Tester
(CMU200, TC-3000B)
Ear set
SAT TEST
EUT
AC/DC Adapter
Notebook
USB Cable DATA CABLE
Ear set
Project Number: 11CA49640 File Number MC16807 Page 11 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
2.7 Performance Assessment
The establishment and maintenance of a communications link, the assessment of RXQUAL, and the assessment of the audio breakthrough by monitoring the speech output signal level, are used as performance criteria to ensure that all primary functions of the transmitter and receiver are evaluated during the immunity tests. In addition, the test shall also be performed in idle mode to ensure the transmitter does not unintentionally operate.
2.7.1 General Performance Criteria
Performance criteria for Continuous phenomena applied to Transmitters (CT) A communication link shall be established at the start of the test, and maintained during the test. During the test, the uplink speech output level shall be at least 35 dB less than the previously recorded reference levels, when measured through an audio band pass filter of width 200 Hz, centred on 1 kHz (audio breakthrough check). At the conclusion of the test, the EUT shall operate as intended with no loss of user control functions or stored data, and the communication link shall have been maintained. In addition to confirming the above performance during a call, the test shall also be performed in idle mode, and the transmitter shall not unintentionally operate.
Performance criteria for Transient phenomena applied to Transmitters (TT) A communications link shall be established at the start of the test. At the conclusion of each exposure the EUT shall operate with no user noticeable loss of the communication link. At the conclusion of the total test comprising the series of individual exposures, the EUT shall operate as intended with no loss of user control functions or stored data, as declared by the manufacturer, and the communication link shall have been maintained. In addition to confirming the above performance during a call, the test shall also be performed in idle mode, and the transmitter shall not unintentionally operate.
Performance criteria for Continuous phenomena applied to Receiver (CR) A communications link shall be established at the start of the test. During the test, the RXQUAL of the downlink shall not exceed the value of three, measured during each individual exposure in the test sequence. During the test, the downlink speech output level shall be at least 35 dB less than the previously recorded reference levels, when measured through an audio band pass filter of width 200 Hz, centred on 1 kHz (audio breakthrough check). At the conclusion of the test, the EUT shall operate as intended with no loss of user control functions or stored data, and the communication link shall have been maintained.
Performance criteria for Transient phenomena applied to Transmitters (TR) A communications link shall be established at the start of the test. At the conclusion of each exposure the EUT shall operate with no user noticeable loss of the communication link. At the conclusion of the total test comprising the series of individual exposures, the EUT shall operate as intended with no loss of user control functions or stored data, as declared by the manufacturer, and the communication link shall have been maintained.
2.7.2 Product Specific Performance
None
Project Number: 11CA49640 File Number MC16807 Page 12 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
2.8 Summary of test result Vehicle mounted MES (V-MES) intended to be powered by the vehicle main battery Portable MES (P-MES) powered by a stand alone battery and external charger Fixed MES (F-MES) powered either by a DC or AC mains
Remark : The EUT is designed for portable use but all the testing has been performed with external chager connected.
There was no deviations from the technical specification of the applied standard Deviation from the technical specification has been observed and ascertained
Application Type Original Assessment Reassessment for engineering change Multiple listing
ETSI EN 301 489-1 and EN 301 489- 7/ -17/ -20 Test Requirements
Phenomenon Port Level Basic standard Verdict
Conducted emission,
0.15 to 30 MHz
AC power Ports Class B
EN 55022:1998+A1:2000 +A2:2003
Complied
Radiated emission,
30 to 1000 MHz
Enclosure Class B
EN 55022:1998+A1:2000 +A2:2003
Complied
Harmonic current emission
AC power Ports Class A EN 61000-3-2: 2001 N/A6
Voltage fluctuation and flicker
AC power Ports Met limit EN 61000-3-3: 1995 Complied
Electrostatic Discharges (ESD)
Enclosure Contact : ± 2,4 kV
Air : ± 2,4,8 kV
EN 61000-4-2: 1995 + A1: 1998 + A2: 2001
N/A5
RF electromagnetic field Enclosure 80MHz to 1000MHz, 1400MHz to 2700MHz 3V/m, AM 80%, 1kHz
EN 61000-4-3: 2002+A1:2002 Complied
Fast transients AC power Ports ± 1kV, 5/50ns, 5kHz EN 61000-4-4: 2004 Complied
Surges AC power Ports ± 1kV, 1.2/50µs, Line to Line
EN 61000-4-5: 1995+A1:2001 Complied
RF Continuous Conducted, Common mode
AC power Ports 3V/m, AM 80%, 1kHz EN 61000-4-6:1996+A1:2001 Complied
Voltage dips and short interruption
AC power Ports 0% of UT : 0.5 cycle, 0% of UT : 1 cycle, 70% of UT : 25 cycle, 0% of UT : 250 cycle,
EN 61000-4-11: 2004 Complied
Project Number: 11CA49640 File Number MC16807 Page 13 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Note: This product has been tested in accordance with the measurement procedures specified in ETSI EN 301 489-1 / EN 301 489-7 at the DigitalEMC Co., Ltd. and the test results has been shown to be complied with the EMC requirements specified in the standard above. N/A1 : Not tested because not required by used standard N/A2 : Test not applicable because port does not exists N/A3 : Test not applicable because port only for services N/A4 : Test not applicable because port lengths not longer than 3m N/A5 : Not tested because not required by customer N/A6 : For equipment with a rated power of ≤ 75 W, other then lighting equipment, no limits are specified in this edition of the standard. N/A7 : No test shall be made on equipment which is unlikely to produce significant voltage fluctuations or flicker. N/A8 : Tested with alternative port permitted in the standard.
Project Number: 11CA49640 File Number MC16807 Page 14 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3. TEST CONDITION AND RESULTS
3.1 Conducted Emission Test
TEST: Limits of mains terminal disturbance voltage
Method Measurements were made on a ground plane that extends 1-meter minimum beyond all sides of the system under test. All power was connected to the system through Artificial Mains Network (AMN). Conducted voltage measurements on mains lines were made at the output of the AMN.
Basic Standard EN 55022:1998+A1:2000+A2:2003
Parameters recorded during the test Laboratory Ambient Temperature 24 °C
Relative Humidity 42 %
- Frequency range on each side of line Measurement Point
Fully configured sample scanned over the following frequency range
150 kHz to 30 MHz AC power input
Limits - Class B
Frequency (MHz)
Limit (dBµV)
Quasi-Peak Result Average Result
0.15 to 0.50 66 to 56 Pass 56 to 46 Pass
0.50 to 5 56 Pass 46 Pass
5 to 30 60 Pass 50 Pass
EUT Configuration Settings:
Power Interface Mode #
(See Section 2.3)
EUT Operation Mode #
(See 2.5)
EUT Configurations Mode #
(See Section 2.6)
1 1,2,3,4 1,2
Conducted Emissions Test Equipment used:
Description Manufacturer Model Identifier Cal. Due
Project Number: 11CA49640 File Number MC16807 Page 15 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Figure 1.1 Test Setup for Conducted Emissions
GSM, BT Mode_Operation mode 1,2,3
Project Number: 11CA49640 File Number MC16807 Page 16 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
SAT Mode_Operation mode 4
Project Number: 11CA49640 File Number MC16807 Page 17 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Figure 1.2 Conducted Emissions Graph
GSM 900 TRAFFIC Mode
Project Number: 11CA49640 File Number MC16807 Page 18 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 19 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
GPRS 900 IDLE Mode
Project Number: 11CA49640 File Number MC16807 Page 20 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 21 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
BT MODE
Project Number: 11CA49640 File Number MC16807 Page 22 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 23 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
SAT MODE
Project Number: 11CA49640 File Number MC16807 Page 24 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 25 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3.2 Radiated Emission
TEST: Limits for radiated disturbance
Method
Measurements were made in a 10-meter semi-anechoic chamber that complies to CISPR 16/ANSI C63.4. Preliminary (peak) measurements were performed at an antenna to EUT separation distance of 10-meter. The EUT was rotated 360° about its azimuth with the receive antenna located at 1, 2, 3 and 4 meter heights in both horizontal and vertical polarities. Final measurements (quasi-peak or average as noted) were then performed by rotating the EUT 360° and adjusting the receive antenna height from 1 to 4-meters. All frequencies were investigated in both horizontal and vertical antenna polarity, where applicable.
Basic Standards EN 55022:1998 + A1: 2000+ A2: 2003
Parameters recorded during the test Laboratory Ambient Temperature 24 °C
Relative Humidity 54 %
Frequency range Measurement Point
Fully configured sample scanned over the following frequency range
30 MHz – 1.0 GHz Enclosure
Limits – Class B
Frequency (MHz) Limit (dBµV/m)
Quasi-Peak Results
30 to 230 30 Pass
230 to 1000 37 Pass
EUT Configuration Settings:
Power Interface Mode #
(See Section 2.3)
EUT Operation Mode #
(See 2.5)
EUT Configurations Mode #
(See Section 2.6)
1 1, 2, 3, 4 1, 2
Radiated Emissions Test Equipment:
Description Manufacturer Model Identifier Cal. Due
EMI TEST RECEIVER
R&S ESU 100014 2012.01.20
Bilog Antenna SCHAFFNER CBL6112B 2737 2012.07.14
Horn Antenna SCHWARZBECK BBHA9120A 322 2012.04.13
Amplifier(22dB) H/P 8447E 2945A02865 2012.01.11
Pre Amplifier TSJ MLA-00108-B02-36 1518831 2012.01.11
Controller TOKIN 5905A N/A -
ANT.master TOKIN N/A N/A -
Project Number: 11CA49640 File Number MC16807 Page 26 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Figure 2.1 Test Setup for Radiated Emission
GSM/ BT Mode_Operation mode 1, 2, 3 30MHz ~ 1GHz
Project Number: 11CA49640 File Number MC16807 Page 27 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
GSM/ BT Mode_Operation mode 1, 2, 3
1GHz ~ 6GHz
Project Number: 11CA49640 File Number MC16807 Page 28 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
SAT Mode_Operation mode 4 30MHz ~ 1GHz
Project Number: 11CA49640 File Number MC16807 Page 29 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
1GHz ~ 6GHz
Project Number: 11CA49640 File Number MC16807 Page 30 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
GSM TRAFFIC MODE (30MHz ~ 1GHz)
902.4 MHz is TX frequency, 947.4 MHz is RX frequency
Project Number: 11CA49640 File Number MC16807 Page 31 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 32 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
GSM TRAFFIC MODE (1GHz ~ 6GHz)
1800.000 MHz, 2700.000 MHz, 3612.500 MHz, 4512.500 MHz 5425.000 MHz are TX harmonics There are no emissions as above data plots
Project Number: 11CA49640 File Number MC16807 Page 33 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 34 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
GSM IDLE MODE (30MHz ~ 1GHz)
947.4MHz is RX frequency
Project Number: 11CA49640 File Number MC16807 Page 35 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 36 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
GSM IDLE MODE (1GHz ~ 6GHz)
There are no emissions as above data plots
Project Number: 11CA49640 File Number MC16807 Page 37 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
BT TRAFFIC MODE (30MHz ~ 1GHz)
Project Number: 11CA49640 File Number MC16807 Page 38 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 39 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
BT TRAFFIC MODE (1GHz ~ 6GHz)
2400.000 MHz are TX frequncy There are no emissions as above data plots
Project Number: 11CA49640 File Number MC16807 Page 40 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 41 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
SAT MODE (30MHz ~ 1GHz)
Project Number: 11CA49640 File Number MC16807 Page 42 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 43 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
SAT MODE (1GHz ~ 6GHz)
1637.500 MHz is TX frequency 3287.500 MHz, 4937.500 MHz are TX harmonics
There are no emissions as above data plots
Project Number: 11CA49640 File Number MC16807 Page 44 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Project Number: 11CA49640 File Number MC16807 Page 45 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3.3 Voltage Fluctuations and Flicker
TEST: Limits of voltage changes, voltage fluctuations and flicker
Method
This test consists on the measurement of voltage changes, voltage fluctuations and flicker which may be produced by equipment having an input current ≤ 16 A per phase, and intended to be connected to public low-voltage distribution systems. The equipment is tested under specified conditions of operation.
Basic Standard EN 61000-3-3:1995
Parameters recorded during the test Laboratory Ambient Temperature 23.0 °C
Relative Humidity 43.0 %
EUT Configuration Settings:
Power Interface Mode #
(See Section 2.3)
EUT Operation Mode #
(See 2.5)
EUT Configurations Mode #
(See Section 2.6)
1 4 2
Test supply voltage specifications
Voltage ± 2 % of the nominal value
Frequency 50 Hz ± 0.5 %
Percentage total harmonic distortion Less than 3 %
Reference impedance (according to IEC 60725)
On phase 0.24 + j 0.15 Ω at 50 Hz
On neutral 0.16 + j 0.10 Ω at 50 Hz
Observation period (Tp) For Pst Tp = 10 minutes, For Plt Tp = 120 minutes
Limits
The value of Pst shall be not greater than 1.0 The value of Plt shall be not greater than 0.65 The value of d(t) during a voltage change shall not exceed 3.3 % for more than 500 ms The relative steady-state voltage change, dc shall not exceed 3.3 % The maximum relative voltage change dmax shall not exceed: a) 4 % without additional conditions b) 6 % for equipment which is: - switched manually, or - switched automatically more frequently than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds), or manual restart, after a power supply interruption c) 7 % for equipment which is - attended whilst in use (for example : hair dryers, vacuum cleaners, kitchen equipment such as mixers, garden equipment such as mowers, portable tools such as electric drills), or - switched on automatically, or is intended to be switched on manually, no more than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds) or manual restart, after a power supply interruption.
Project Number: 11CA49640 File Number MC16807 Page 46 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Test Equipment Used
Description Manufacturer Model Identifier Cal. Due
POWER ANALYZER VOLTECH
INSTUMENT PM6000 100006700031 2012.07.12
Reference Impedance Network
NF CORPORATION
ES4152 424059 2012.09.30
CVCF NF
CORPORATION 4420 304935/337980 2012.03.08
Figure 3.1 Photo of test setup
Project Number: 11CA49640 File Number MC16807 Page 47 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Table 3.1 Voltage fluctuation and flicker test data of SAT Mode
Parameter Result Parameter Result
Pst Pass dc Pass
Plt N/A dmax Pass
d(t) Pass -
Project Number: 11CA49640 File Number MC16807 Page 48 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3.4 Electrolectrostatic Discharge (ESD) : Test was not performed
TEST: Electrostatic Discharge
Method Measurements were made on a ground plane that extends 0.5-meter minimum beyond all sides of the system under test and the minimum distance between the equipment under test and any laboratory walls or any other metallic surfaces shall be at least 1-meter. Air discharges were applied to non-metallic parts of the system. Contact discharges were applied to all accessible metallic parts. Discharges were also applied to the Horizontal and Vertical Coupling Planes, where applicable. Each discharge was applied at a rate of one (1) discharge per second.
Basic Standard EN 61000-4-2:1995+A2: 2001
Parameters required prior to the test Laboratory Ambient Temperature °C
Relative Humidity %
Parameters recorded during the test
Laboratory Ambient Temperature
Relative Humidity %
Air pressure mbar
- Measurement Point
Fully configured sample subjected to the levels shown below.
Enclosure
Test Levels:
Discharge type Discharge Level (kV) Number of discharges per location (each polarity) Positive Positive Negative
Air – Direct 2, 4, 8 2, 4, 8 10
Contact – Direct 2, 4 2, 4 10
Contact – Indirect 2, 4 2, 4 10
EUT Configuration Settings:
Power Interface Mode #
(See Section 2.3)
EUT Operation Mode #
(See 2.5)
EUT Configurations Mode #
(See Section 2.6)
ESD Test Equipment used:
Description Manufacturer Model Identifier Cal. Due
Project Number: 11CA49640 File Number MC16807 Page 49 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3.5 RF Electromagnetic Field Immunity
TEST: Radio-frequency electromagnetic field Amplitude modulated
Method Measurements were made in a fully anechoic chamber and the indicated field strength was pre-calibrated prior to placement of the system under test. Tests were performed in both the horizontal and vertical polarities, where applicable. The antenna was placed 3 meters from the product under test. All sides of the EUT were investigated for anomalies.
Parameters recorded during the test Laboratory Ambient Temperature 21
Relative Humidity 46 %
Basic Standard EN 61000-4-3:2002+A1: 2002
- Frequency range Measurement Point
Fully configured sample scanned over the following frequency range
80.0 MHz – 2,7 GHz Enclosure
Applied Field Strength:
Frequency (MHz) (V/m) Modulation
80 – 1000 3 80 % AM (1 kHz)
1400 – 2700 3 80 % AM (1 kHz)
EUT Configuration Settings:
Power Interface Mode #
(See Section 2.3)
EUT Operation Mode #
(See 2.5)
EUT Configurations Mode #
(See Section 2.6)
1 1, 2, 3, 4 1, 2
Receiver exclusion band The lower frequency of the exclusion band is the lower frequency of the receive band of the EUT minus 6 % of that frequency.
The upper frequency of the exclusion band is the upper frequency of the receive band of the EUT plus 5 % of that frequency.
Transmitter exclusion band The exclusion band for transmitters extends three times the channel separation (3 × 200 kHz = 600 kHz) centred on the nominal operating frequency of the transmitter.
Project Number: 11CA49640 File Number MC16807 Page 50 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Radiated RF Field Immunity test equipment used:
Description Manufacturer Model Identifier Cal. Due
SIGNAL GENERATOR HP 8648C 3847U02308 2012.07.26
POWER METEER HP 438A 3513U04164 2012.07.26
POWER AMPLIFIER PRANA MT100 1099 -
POWER AMPLIFIER PRANA DP70 1098 -
DUAL DIRECTIONAL COUPLERS
ATM CHP272L-40F-40R M185203-01 -
DUAL DIRECTIONAL COUPLERS
WERLATONE C39100-712 94894 -
DUAL DIRECTIONAL COUPLERS
WERLATONE C5086-712 94950 -
POWER SENSOR HP 8482A 3318A95113 2012.07.26
POWER SENSOR HP 8482A US38290170 2012.07.26
LOG-PER ANTENNE SCHWARZBECK VULP 9118 9118E890 -
Horn Antenna SCHWARZBECK BBHA9120A 556 -
Project Number: 11CA49640 File Number MC16807 Page 51 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Figure 5.1 Radiated RF Field Immunity Test Setup
Photos of the RF Field Immunity Test Setup_Operation mode 1,2,3
WITH EARMIC
WITHOUT EARMIC
Project Number: 11CA49640 File Number MC16807 Page 52 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Photos of the RF Field Immunity Test Setup_Operation mode 4
SAT MODE
Project Number: 11CA49640 File Number MC16807 Page 53 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Table 5.1 Result for the RF Field Immunity Test_GSM 900 Calling Mode
Test Location Polarity Results Test Location Polarity Results
Front Horizontal A Front Vertical A
Left Side Horizontal A Left Side Vertical A
Right Side Horizontal A Right Side Vertical A
Rear Horizontal A Rear Vertical A
Bottom side Horizontal A Bottom side Vertical A
Top side Horizontal A Top side Vertical A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Table 5.2 Result for the RF Field Immunity Test_BT Mode
Test Location Polarity Results Test Location Polarity Results
Front Horizontal A Front Vertical A
Left Side Horizontal A Left Side Vertical A
Right Side Horizontal A Right Side Vertical A
Rear Horizontal A Rear Vertical A
Bottom side Horizontal A Bottom side Vertical A
Top side Horizontal A Top side Vertical A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Table 5.3 Result for the RF Field Immunity Test_SAT Mode
Test Location Polarity Results Test Location Polarity Results
Front Horizontal A Front Vertical A
Left Side Horizontal A Left Side Vertical A
Right Side Horizontal A Right Side Vertical A
Rear Horizontal A Rear Vertical A
Bottom side Horizontal A Bottom side Vertical A
Top side Horizontal A Top side Vertical A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Project Number: 11CA49640 File Number MC16807 Page 54 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3.6 Electrical Fast Transients
TEST: Electrical Fast Transients
Method Measurements were made on a ground plane that extends 1-meter minimum beyond all sides of the system under test. Mains power tests were conducted with the product connected to a Coupling/Decoupling Network (CDN). One of each unique interface was tested for a period of one (1) minute per polarity.
Parameters recorded during the test Laboratory Ambient Temperature 26
Relative Humidity 41 %
Basic Standard EN 61000-4-4: 2004
Measurement Port
Fully configured sample subject to the levels shown below.
A.C Main Power Input Ports
Applied Level:
Application Point (kV) Repetition Frequency (kHz)
Input A.C. Power Port 1.0 5
EUT Configuration Settings:
Power Interface Mode #
(See Section 2.3)
EUT Operation Mode #
(See 2.5)
EUT Configurations Mode #
(See Section 2.6)
1 1, 2, 3, 4 1, 2
Electrical Fast Transient Test Equipment used:
Description Manufacturer Model Identifier Cal. Due
ULTRA COMPACT SIMULATOR
EMTEST UCS 500 N5 V1113109125 2012.03.21
Project Number: 11CA49640 File Number MC16807 Page 55 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Figure 6.1 Photo of Electrical Fast Transient test setup
Photos of the Electrical Fast Transient Test Setup_Operation mode 1, 2, 3
Photos of the Electrical Fast Transient Test Setup_Operation mode 4
Project Number: 11CA49640 File Number MC16807 Page 56 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Table 6.1 Results for Electrical Fast Transients_GSM 900 Calling Mode
Applied port Point of application Results Point of application Results
Main power input L1 A L1+L2 A
L2 A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Table 6.2 Results for Electrical Fast Transients_BT Mode
Applied port Point of application Results Point of application Results
Main power input L1 A L1+L2 A
L2 A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Table 6.3 Results for Electrical Fast Transients_SAT Mode
Applied port Point of application Results Point of application Results
Main power input L1 A L1+L2 A
L2 A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Project Number: 11CA49640 File Number MC16807 Page 57 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3.7 Surges
TEST: Surges Immunity
Method Mains power tests were conducted with the product connected to a Coupling/Decoupling Network (CDN). The test voltage was increased from the lowest indicated level up to the maximum level. Five (5) positive surges and five (5) negative surges were applied at each of phases of the a.c. waveform: 0°, 90°, 180° and 270°. Each surge was applied 60 seconds after the previous surge. Signal and Telecommunications ports were subject to five (5) positive and five (negative) surges applied through the appropriate Coupling/Decoupling Network (CDN).
Basic Standard EN 61000-4-5:1995+A1: 2001
Parameters recorded during the test Laboratory Ambient Temperature 21
Relative Humidity 43 %
- Measurement Point
Fully configured sample subject to the levels shown below.
AC mains power input
Applied Level:
Application Point (kV) Required Surge Waveform
AC mains port
± 1.0 (Line to Line)
1.2/50µS Voltage (8/20µS, Current)
± 2.0 (Line to Ground)
1.2/50µS Voltage (8/20µS, Current)
EUT Configuration Settings:
Power Interface Mode #
(See Section 2.3)
EUT Operation Mode #
(See 2.5)
EUT Configurations Mode #
(See Section 2.6)
1 1, 2, 3, 4 1, 2
Surge Immunity Test Equipment:
Description Manufacturer Model Identifier Cal. Due
ULTRA COMPACT SIMULATOR
EMTEST UCS 500 N5 V1113109125 2012.03.21
Project Number: 11CA49640 File Number MC16807 Page 58 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Figure 7.1 Photo of Surges test setup
Photos of the Surges_Operation mode 1, 2,3
Photos of the Surges_Operation mode 4
Project Number: 11CA49640 File Number MC16807 Page 59 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Table 7.1 Results for Surges_GSM 900 Calling Mode
Mode of Application - Mains Level Polarity Result
Differential mode L to N 1.0 kV Positive A
Negative A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Table 7.2 Results for Surges_BT Mode
Mode of Application - Mains Level Polarity Result
Differential mode L to N 1.0 kV Positive A
Negative A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Table 7.3 Results for Surges_SAT Mode
Mode of Application - Mains Level Polarity Result
Differential mode L to N 1.0 kV Positive A
Negative A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Project Number: 11CA49640 File Number MC16807 Page 60 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3.8 Radio Frequency, Common Mode
TEST: Radio-Frequency Common Mode
Method Measurements were made on a ground plane that extends 0.5-meter minimum beyond all sides of the system under test. The EUT was located 10cm above the reference ground plane and any associated I/O cables attached to the EUT were located between 30mm and 50mm above the ground plane. The indicated field was pre-calibrated prior to placement of the system under test.
Basic Standard EN 61000-4-6:1996+A1: 2001
Parameters recorded during the test Laboratory Ambient Temperature 21
Relative Humidity 49 %
- Frequency range Measurement Point
Fully configured sample scanned over the following frequency range
150 kHz to 80 MHz AC Main Power input Ports
Applied Level:
Frequency (MHz) (Vrms) Modulation
0.150 – 80 MHz 3 80 % AM (1kHz)
Supplementary information: Frequency step: 1 %, Dwell time at each frequency: 3 s
EUT Configuration Settings:
Power Interface Mode # (See Section 2.3)
EUT Operation Mode # (See 2.5)
EUT Configurations Mode # (See Section 2.6)
1 1, 2, 3, 4 1, 2
Conducted Immunity Test Equipment used:
Description H.P Model Identifier Cal. Due
Signal Generator H.P 8657B 3630U08728 2012.07.02
Power Meter H.P 438A 3048U02191 2012.07.02
Power Sensor H.P 8482A MY41090826 2012.09.30
Power Sensor Frankonia 8482A 3630U08728 2012.07.02
RF Power Amplifier (~230MHz, 75W)
TSJ FLL75 0072 N/A
CDN TSJ TSCDN-M2-16A 2008 2012.07.01
Project Number: 11CA49640 File Number MC16807 Page 61 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Figure 8.1 Photo of Radio Frequency, Common Mode test setup
Photos of the Radio Frequency, Common Mode test setup_Operation mode 1, 2, 3
Photos of the Radio Frequency, Common Mode test setup_Operation mode 4
Project Number: 11CA49640 File Number MC16807 Page 62 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Table 8.1 Results for Radio Frequency, Common Mode_GSM 900 Calling Mode
Point of application Coupling Results
AC Main power input Ports CDN M2 A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Table 8.2 Results for Radio Frequency, Common Mode_BT Mode
Point of application Coupling Results
AC Main power input Ports CDN M2 A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Table 8.3 Results for Radio Frequency, Common Mode_SAT Mode
Point of application Coupling Results
AC Main power input Ports CDN M2 A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report
X - Not Performed.
Project Number: 11CA49640 File Number MC16807 Page 63 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
3.9 Voltage Dips and Interruptions
TEST: Voltage Dips and Interruptions
Method The product was subjected to voltage dips and interruptions. Testing was performed with the product connected directly to a generator capable of simulating the voltage drops and interrupts as described
Parameters recorded during the test Laboratory Ambient Temperature 23
Relative Humidity 46 %
Basic Standard EN 61000-4-11: 2004
- Measurement Point
Fully configured subjected to the levels indicated below. AC Mains Power Input port
Applied Levels:
Voltage Reduction Period (Cycles) Sync Angle (degrees)
30% 0.5 cycle 0, 180
60% 5.0 cycle 0, 180
≥95% 250 cycle 0, 180
EUT Configuration Settings:
Power Interface Mode #
(See Section 2.3)
EUT Operation Mode #
(See 2.5)
EUT Configurations Mode #
(See Section 2.6)
1 4 2
Voltage dips and Short Interruption Test Equipment:
Description Manufacturer Model Identifier Cal. Due
ULTRA COMPACT SIMULATOR
EMTEST UCS 500 N5 V1113109125 2012.03.21
MOTOR VARIAC EMTEST MV2616 V1113109126 2012.03.21
Project Number: 11CA49640 File Number MC16807 Page 64 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Figure 9.1 Photo of Voltage Dips and Interruptions test setup
Photos of the Voltage Dips and Interruptions test setup_Operation mode 4
Table 9.1 Results for Voltage Dips and interruptions _GSM 900 Calling Mode
Point of application Voltage Reduction Period (Cycles) Results
Mains power input 0% 0.5 cycle A
Mains power input 0% 1 cycle A
Mains power input 70% 25 cycle A
Mains power input 0% 250 cycle A
Results Descriptions: A – Compliant – met the performance criteria Continuous phenomena applied to Transmitter and Receiver according to the clause 2.7.1 of this report B – Compliant – During the interruption period, the LCD panel was getting brighter or turned on when the EUT was in energy saving mode.
X - Not Performed.
Project Number: 11CA49640 File Number MC16807 Page 65 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Appendix A. Product Photos_External
Front side
Rear side
Project Number: 11CA49640 File Number MC16807 Page 66 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Battery separated
AC/DC Adapter
Project Number: 11CA49640 File Number MC16807 Page 67 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
AC/DC Adapter_LABEL
EARMIC
Project Number: 11CA49640 File Number MC16807 Page 68 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
BATTERY
Project Number: 11CA49640 File Number MC16807 Page 69 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
BATTERY_LABEL
Project Number: 11CA49640 File Number MC16807 Page 70 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
Appendix B. Product Photos_Internal
Project Number: 11CA49640 File Number MC16807 Page 71 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
APPENDIX C - ACCREDITATIONS AND AUTHORIZATIONS
KCC: Designated as a testing laboratory by Radio Research Laboratory in accordance with the Regulation on Designation of Testing Laboratory for Information and Communication Equipment. Registration No. : KR0034
KOLAS: Accredited by Korea Laboratory Accreditation Scheme (KOLAS) as Testing Laboratory in accordance with the provisions of Article 23 of the National Standards Act. These criteria encompass the requirements of ISO/IEC 17025:2006. For a scope listing search at http://kolas.kats.go.kr/WebApp/Main/Search/Search0010.aspx?CompanyNo=3793&AccreditNo=3663&BigID=03
FCC: Details of the measurement facilities used for these tests have been filed with the Federal Communications Commission’s Laboratory in Columbia, Maryland and accepted in a letter dated May 28, 2010 (Reg. No. 678747). As a Conformity Assessment Body (CAB), our organization is designated to perform compliance testing on equipment subject to Declaration Of Conformity (DOC) and Certification under Part 15 and 18 of the Commission’s Rules in a letter dated May 28, 2010.
VCCI: Accepted as an Associate Member to the VCCI. The measurement facilities detailed in this test report have been registered in accordance with Regulations for Voluntary Control Measures, Article 8. Registration Nos.: (Radiated Emissions) R-3385, (Conducted Emissions) C-1427.
Project Number: 11CA49640 File Number MC16807 Page 72 of 72 Model Number: XT DUAL
UL Korea, Ltd. 33rd
FL, Gangnam Finance Center, 737 Yeoksam-dong, Gangnam-gu, Seoul 135-984 Korea Tel: +82.2.2009.9000, Fax:+82.2.2009.9405 Report Version 1.2 June-06,2007
Only those products bearing the UL Mark should be considered as being covered by UL.
APPENDIX D - MEASUREMENT UNCERTAINTIES
Test Item Measurement uncertainty
Conducted emission ± 4.43 dB, Note 1
Radiateded emission ± 3.47 dB, Note 1
Harmonic ± 7.10 %, Note 1
Fliker ± 7.66 %, Note 1
ESD At least a 95 % confidence
Radiated RF-electromagnetic field ± 1.38 dB, Note 1
Electrical fast transient/burst At least a 95 % confidence
Surge At least a 95 % confidence
Conducted RF field immunity ± 1.38 dB, Note 1
Magnetic Field At least a 95 % confidence
Voltage dips and short interruption At least a 95 % confidence
Note 1:Measurement uncertainty is calculated in according with LAB34(2002-08). The measurement uncertainty is given with a confidence of 95% with the coverage factor, k=2.