This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
UL 1007 CSA TR-64 SUPERCOMALHeat-resistant PVC Insulated Wire
Features : Application :- Bare/Tinned annealed, stranded or solid conductor. - For internal wiring of electrical and- Colour-coded PVC insulated. electronic equipment.- Rating temperature : 80°C (CSA : 90°C) - Rating voltage : 300V- Flammability : UL VW-1 / CSA FT1 / Japan -F-- Uniform thickness of wire enable easy stripping & cutting.
Construction and Characteristics :
Conductor Insulation
Conductor Insulation Max. cond. Min. ins. Dielectric Packing
Size Stranding Strand Thickness Nominal resistance resistance withstand LengthType (AWG) (No/mm) O.D Average O.D. 25°C 20°C voltage per roll
Remark : 1. Under UL Subject 758, the minimum thickness is 0.381mm (average) and 0.330mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
UL 1061 CSA AWM IA SUPERCOMALHeat-resistant Semi-rigid PVC Insulated Wire
Features : Application :- Bare/Tinned annealed, stranded or solid conductor. - For internal wiring of electrical and- Colour-coded PVC insulated. electronic equipment.- Rating temperature : 80°C - Wiring of small equipment where- Rating voltage : 300V space is limited.- Flammability : UL VW-1 / CSA FT1 / Japan -F-- Uniform thickness of wire enable easy stripping & cutting.- Excellent abrasion and cut through resistance.- Small outer diameter saves space.
Construction and Characteristics :
Conductor Insulation
Conductor Insulation Max. cond. Min. ins. Dielectric Packing
Size Stranding Strand Thickness Nominal resistance resistance withstand LengthType (AWG) (No/mm) O.D Average O.D. 25°C 20°C voltage per roll
Remark : 1. Under UL Subject 758, the minimum thickness is 0.229mm (average) and 0.178mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
UL 1185 CSA TR-64 SUPERCOMALHeat-resistant PVC Insulated Shielded Wire
Features : Application :- Stranded bare/tinned annealed conductor. - For internal wiring of electrical and- Colour-coded PVC insulated. electronic equipment requiring heat- Overall tinned or bare copper shielded. resistance.- Colour-coded PVC jacketed.- Rating temperature : 80°C (CSA : 90°C) - Rating voltage : 300V- Flammability : UL VW-1SC / CSA FT1 / Japan -F-- Use of spiral shield enable fast and simple termination.
Construction and Characteristics : Conductor
Insulation Shielded wire Jacket
Conductor Insulation Shielded Jacket Max. cond. Min. ins. Dielectric Packing
Remark : 1. Under UL Subject 758, the minimum thickness for insulation wire and jacket is 0.381mm (average) and 0.330mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
UL 1533 SUPERCOMALHeat-resistant Semi-rigid PVC Insulated Shielded Wire
Features : Application :- Stranded bare/tinned annealed conductor. - For internal wiring of electronic- Semi-rigid PVC insulated. equipment where not exposed to- Overall tinned or bare copper shielded. movement or mechanical abuse.- Colour-coded PVC jacketed.- Rating temperature : 80°C- Rating voltage : Not specified.- Flammability : UL VW-1SC / Japan -F-- Use of spiral shield enable fast and simple termination.- Small diameter saves space.
Construction and Characteristics : Conductor
Insulation Shielded wire Jacket
Conductor Insulation Shielded Jacket Max. cond. Min. ins. Dielectric Packing
Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.229mm (average) and 0.178mm (at any point). While, for the jacket is 0.304mm (average) and 0.254mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- Bare/Tinned annealed, stranded or solid conductor. - Internal wiring of small electronic- Colour-coded PVC insulated. equipment.- Rating temperature : 80°C - Internal wiring of micro-cassette- Rating voltage : 30V tape recorder, player, radio- Flammability : UL VW-1 / Japan -F- receiver etc.- Uniform thickness of wire enable easy stripping & cutting.- Excellent abrasion and cut through resistance.- Small outer diameter saves space.
Construction and Characteristics :
Conductor Insulation
Conductor Insulation Max. cond. Min. ins. Dielectric Packing
Size Stranding Strand Thickness Nominal resistance resistance withstand LengthType (AWG) (No/mm) O.D Average O.D. 25°C 20°C voltage per roll
(mm) (mm) (mm) ( Ω/km) (M Ω/km) (AC/1 min)
28 7/0.127 0.39 0.23 0.85 242.02
26 7/0.160 0.49 0.23 0.95 152.21
24 11/0.160 0.61 0.22 1.05 95.28
22 17/0.160 0.76 0.22 1.20 56.1 4000Ft
28 7/0.127 0.39 0.23 0.85 242.02 5 500
26 7/0.160 0.49 0.23 0.95 152.21 (1220M)
24 7/0.200 0.61 0.22 1.05 95.28
22 7/0.254 0.78 0.21 1.20 56.1
Solid 24 1/0.511 0.51 0.21 0.95 91.16
22 1/0.643 0.64 0.22 1.10 55.3
Remark : 1. Under UL Subject 758, the minimum thickness is 0.051mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.762mm (average) and 0.686mm (at any point). While, for the jacket is 0.178mm (average) and 0.127mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.381mm (average) and 0.330mm (at any point). While, for the jacket is 0.305mm (average) and 0.254mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
UL 1759 SUPERCOMALPVC Insulated Wire for Appliance Hook Up Use
Features : Application :- Bare/Tinned annealed, stranded or solid conductor. - For internal wiring of electrical and- Colour-coded PVC insulated. electronic equipment.- Rating temperature : 105°C - Rating voltage : 300V- Flammability : UL VW-1 / Japan -F-- Uniform thickness of wire enable easy stripping & cutting.
Construction and Characteristics :
Conductor Insulation
Conductor Insulation Max. cond. Min. ins. Dielectric Packing
Size Stranding Strand Thickness Nominal resistance resistance withstand LengthType (AWG) (No/mm) O.D Average O.D. 25°C 20°C voltage per roll
mm mm ( Ω/km) (M Ω/km) (AC/1 min)28 7/0.127 0.39 0.43 1.25 242.02
26 7/0.160 0.49 0.43 1.35 152.21
24 11/0.160 0.61 0.42 1.45 95.28
22 17/0.160 0.76 0.47 1.70 56.1
20 21/0.180 0.95 0.42 1.80 35.3
18 34/0.180 1.21 0.47 2.15 22.2 2000Ft
16 26/0.254 1.50 0.45 2.40 14.0 15 2000
28 7/0.127 0.39 0.43 1.25 242.02 (610M)
26 7/0.160 0.49 0.43 1.35 152.21
24 7/0.200 0.61 0.42 1.45 95.28
22 7/0.254 0.78 0.46 1.70 56.1
24 1/0.511 0.51 0.41 1.35 91.16
Solid 22 1/0.643 0.64 0.42 1.50 55.3
20 1/0.813 0.81 0.44 1.70 34.6
18 1/1.020 1.02 0.44 1.90 21.8
Remark : 1. Under UL Subject 758, the minimum thickness is 0.381mm (average) and 0.330mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- Bare/Tinned annealed, stranded or solid conductor. - For further processing as single - Colour-coded PVC insulated. conductor in multi-conductor- Rating temperature : 105°C jacket cables or flat ribbon type- Rating voltage : 300V cables.- Flammability : UL VW-1 / Japan -F-- Uniform thickness of wire enable easy stripping & cutting.
Construction and Characteristics :
Conductor Insulation
Conductor Insulation Max. cond. Min. ins. Dielectric Packing
Size Stranding Strand Thickness Nominal resistance resistance withstand LengthType (AWG) (No/mm) O.D Average O.D. 25°C 20°C voltage per roll
Remark : 1. Under UL Subject 758, the minimum thickness is 0.381mm (average) and 0.330mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Remark : 1. Under UL Subject 758, the minimum thickness for insulation and jacket is 0.381mm (average) and 0.330mm (at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Strandedtinnedcopper
1000Ft(305M)
or
500ft(153M)
AWM STYLE 2092 60°C 300V VW-1 E151684 SUPERCOMAL
Insulation
Al-mylar tape Jacket
Conductor
Drain wire
5 3000
UL 2464 CSA I/II A SUPERCOMALHeat-resistant Semi-rigid PVC Insulated Computer Cable
Features : Application :- Stranded bare/tinned annealed conductor. - Control, instrumentation and computer- Multi-conductor Semi-rigid PVC insulated. cable for EIA RS-232 and CAD/CAM- 100% Aluminium mylar shield with drain wire. applications.- Tinned copper braid shield with 65% coverage.- Colour-coded PVC jacketed.- Rating temperature : 80°C- Rating voltage : 300V- Flammability : UL VW-1SC / CSA I/IIA
Construction and Characteristics :
Conductor Insulation Braided Jacket Max. cond. Min. ins. Dielectric Packing
Size Strand Strand Thickness Nom. No. Size Nom. Thickness Nom. resistance resistance withstand LengthType (AWG) (No/mm) O.D Average O.D. of (mm) O.D. Average O.D. 25°C 20°C voltage per roll
Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.229mm (average) and 0.178mm (at any point). While, for the jacket is 0.762mm (average) and 0.610mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Type (AWG) (No/mm) O.D Average (thickness x width) 25°C 20°C voltage per roll
(mm) (mm) (mm) ( Ω/km) (M Ω/km) (AC/1 min)
26 7/0.160 0.49 0.45 1.40 x 2.80 152.21
24 11/0.160 0.61 0.54 1.70 x 3.40 95.28
22 17/0.160 0.76 0.57 1.90 x 3.80 56.1
20 21/0.180 0.95 0.57 2.10 x 4.20 35.3
18 34/0.180 1.21 0.49 2.20 x 4.40 22.2
26 7/0.160 0.49 0.45 1.40 x 2.80 152.21 15 2000
24 7/0.200 0.61 0.54 1.70 x 3.40 95.28
22 7/0.254 0.78 0.56 1.90 x 3.80 56.1
24 1/0.511 051 0.59 1.70 x 3.40 91.16
Solid 22 1/0.643 064 0.57 1.80 x 3.60 55.3
20 1/0.813 081 0.59 2.00 x 4.00 34.6
18 1/1.020 1.02 0.59 2.20 x 4.40 21.8
Remark : 1. Under UL Subject 758, the minimum thickness is 0.381mm (average) and 0.330mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
AWM 2468 E151684 VW-1 80°C 300V **AWG SUPERCOMAL CSA TYPE IA AWM **AWG FT1 90°C 300V LL96647 -F-
Stranded(Bare)
or(Tinned)
TOPor
OS-1
2000Ft(610M)
or
1000Ft(305M)
UL 2468 CSA IA AWM SUPERCOMALHeat-resistant PVC Insulated Flat Ribbon Wire
Features : Application :- Bare/Tinned annealed, stranded, TOP or OS-1 - For internal wiring of audio / video- PVC insulated. equipment.- Rating temperature : 80°C (CSA : 90°C)- Rating voltage : 300V- Flammability : UL VW-1 / CSA FT1 / Japan -F-- Uniform thickness of wire enable easy stripping & cutting
Construction and Characteristics : Conductor Insulation
Conductor Insulation Max. cond. Min. ins. Dielectric Packing
No Size Strand Strand Thickness Diamension resistance resistance withstand Length
Type of (AWG) (No/mm) O.D Average (thickness x width) 25°C 20°C voltage per roll
core (mm) (mm) (mm) ( Ω/km) (M Ω/km) (AC/1 min)2 1.35 x 2.803 1.35 x 4.254 1.35 x 5.705 26 0.49 0.43 1.35 x 7.15 152.216 1.35 x 8.60
Stranded 7 1.35 x 10.05(bare) 8 1.35 x 11.50 2000Ft
or 2 1.50 x 3.70 (610M)(tinned) 3 1.50 x 4.70
4 24 0.62 0.43 1.50 x 6.30 95.28 10 2000 orTOP 5 1.50 x 7.90
or 6 1.50 x 9.50 1000FtOS-1 7 1.50 x 11.10 (305M)
8 1.50 x 12.702 1.65 x 3.403 1.65 x 5.154 22 0.78 0.43 1.65 x 6.90 56.15 1.65 x 8.656 1.65 x 10.407 1.65 x 12.15
Remark : 1. Under UL Subject 758, the minimum thickness is 0.381mm (average) and 0.330mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
AWM 2468 E151684 VW-1 80°C 300V **AWG SUPERCOMAL CSA TYPE IA AWM **AWG FT1 90°C 300V LL96647 -F-
I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I
I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I
11/0.16stranded
or7/0.203
TOP/OS-1
17/0.16stranded
or7/0.254
TOP/OS-1
7/0.16stranded
orTOP/OS-1
UL 2468 CSA IA AWM SUPERCOMALHeat-resistant PVC Insulated Flat Ribbon Wire (P:2.0mm)
Features : Application :- Bare/Tinned annealed, stranded, TOP or OS-1 - For internal wiring of audio / video- PVC insulated. equipment.- Rating temperature : 80°C (CSA : 90°C)- Rating voltage : 300V- Flammability : UL VW-1 / CSA FT1 / Japan -F-- Uniform thickness of wire enable easy stripping & cutting
Construction and Characteristics :Line printing (Top & Bottom)
Type of (AWG) (No/mm) O.D Average (diameter x width) 25°C 20°C voltage per rollcore (mm) (mm) (mm) ( Ω/km) (M Ω/km) (AC/1 min)
2 1.35 x 3.353 1.35 x 5.354 1.35 x 7.355 26 0.49 0.43 1.35 x 9.35 152.216 1.35 x 11.357 1.35 x 13.358 1.35 x 15.359 1.35 x 17.35
10 1.35 x 19.35Stranded 2 1.50 x 3.50 2000Ft
(bare) 3 1.50 x 5.50 (610M)or 4 1.50 x 7.50
(tinned) 5 24 0.62 0.43 1.50 x 9.50 95.28 10 2000 or6 1.50 x 11.50
TOP 7 1.50 x 13.50 1000Ftor 8 1.50 x 15.50 (305M)
OS-1 9 1.50 x 17.5010 1.50 x 19.502 1.65 x 3.653 1.65 x 5.654 1.65 x 7.655 22 0.78 0.43 1.65 x 9.65 56.16 1.65 x 11.657 1.65 x 13.658 1.65 x 15.659 1.65 x 17.65
10 1.65 x 19.65 Remark : 1. Under UL Subject 758, the minimum thickness is 0.381mm (average) and 0.330mm (at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
11/0.16stranded
or7/0.203
TOP/OS-1
17/0.16stranded
or7/0.254
TOP/OS-1
7/0.16stranded
orTOP/OS-1
AWM 2468 E151684 VW-1 80°C 300V **AWG SUPERCOMALCSA TYPE IA AWM **AWG FT1 90°C 300V LL96647 -F-
p
d
W
UL 2651 CSA IA AWM SUPERCOMALHeat-resistant PVC Insulated Flat Ribbon Wire (P:2.5mm)
Features : Application :- Bare/Tinned annealed, stranded, TOP or OS-1 - For internal wiring of audio / video- PVC insulated. equipment.- Rating temperature : 105°C - Rating voltage : 300V- Flammability : UL VW-1 / CSA FT1 / Japan -F-- Uniform thickness of wire enable easy stripping & cutting
Construction and Characteristics :Line printing (Top & Bottom)
Type of (AWG) (No/mm) O.D Average (diameter x width) 25°C 20°C voltage per rollcore (mm) (mm) (mm) ( Ω/km) (M Ω/km) (AC/1 min)
2 1.35 x 3.853 1.35 x 6.354 1.35 x 8.855 26 0.49 0.43 1.35 x 11.35 152.216 1.35 x 13.857 1.35 x 16.358 1.35 x 18.859 1.35 x 21.35
10 1.35 x 23.85Stranded 2 1.50 x 4.00 2000Ft
(bare) 3 1.50 x 6.50 (610M)or 4 1.50 x 9.00
(tinned) 5 24 0.62 0.43 1.50 x 11.50 95.28 10 2000 or6 1.50 x 14.00
TOP 7 1.50 x 16.50 1000Ftor 8 1.50 x 19.00 (305M)
OS-1 9 1.50 x 21.5010 1.50 x 24.002 1.65 x 4.153 1.65 x 6.654 1.65 x 9.155 22 0.78 0.43 1.65 x 11.65 56.16 1.65 x 14.157 1.65 x 16.658 1.65 x 19.159 1.65 x 21.65
10 1.65 x 24.15 Remark : 1. Under UL Subject 758, the minimum thickness is 0.381mm (average) and 0.330mm (at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
11/0.16stranded
or7/0.203
TOP/OS-1
17/0.16stranded
or7/0.254
TOP/OS-1
7/0.16stranded
orTOP/OS-1
AWM 2651 E151684 VW-1 105°C 300V **AWG SUPERCOMALCSA TYPE IA AWM **AWG FT1 105°C 300V LL96647 -F-
p
d
W
UL 2652 CSA TR-64 SUPERCOMALParallel PVC Insulated Shielded Wire
Features : Application :- Stranded tinned annealed conductor. - For internal wiring of electronic- PVC insulated. equipment.- Overall tinned copper shielded.- Colour-coded PVC jacketed.- Rating temperature : 80°C- Rating voltage : 300V- Flammability : UL VW-1SC / CSA FT1 / Japan -F-- Use of spiral shield enable fast and simple termination.
Construction and Characteristics :
Conductor Insulation Shielded Jacket Max. cond. Min. ins. Dielectric Packing
Remark : 1. Under UL Subject 758, the minimum thickness for insulation and jacket is 0.381mm (average) and 0.330mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
37 7.52 0.34 8.20 Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.152mm (at any point). While, for the jacket is 0.229mm
(average) and 0.178mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Stranded(Bare)
or(Tinned)
1000Ft(305M)
or
500ft(153M)
AWM STYLE 2725 **°C 30V VW-1 E151684 SUPERCOMAL
Insulation
Paper tape Jacket
Conductor
UL 2733 SUPERCOMALHeat-resistant PVC Insulated Cable
Features : Application :- Stranded bare/tinned annealed conductor. - For internal wiring of electric fans.- 2 to 7 conductor PVC insulated.- Colour-coded PVC jacketed.- Rating temperature : 105°C- Rating voltage : 600V- Flammability : UL VW-1SC / Japan -F-
Construction and Characteristics :
Conductor Insulation Jacket Max. cond. Min. ins. Dielectric Packing
Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.762mm (average) and 0.686mm (at any point). While, for the jacket is 0.381mm (average) and 0.330mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.152mm (at any point). While, for the jacket is 0.762mm (average) and 0.610mm (at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Stranded(Bare)
or(Tinned)
1000Ft(305M)
or
500ft(153M)
AWM 2789 E151684 VW-1 60°C 30V **AWG SUPERCOMAL
Insulation
Aluminium mylar foilJacket
Drain wire
Conductor
5 1500
UL 2854 SUPERCOMALHeat-resistant Semi-rigid PVC Insulated Shielded Wire
Features : Application :- Stranded bare/tinned annealed conductor. - For internal wiring of electronic- Multi-conductor Semi-rigid PVC insulated. equipment.- Overall tinned or bare copper shielded.- Colour-coded PVC jacketed.- Rating temperature : 80°C- Rating voltage : 30V- Flammability : UL VW-1SC / Japan -F-- Use of spiral shield enable fast and simple termination.- Small diameter saves space.
Construction and Characteristics :
Conductor Insulation Shielded Jacket Max. cond. Min. ins. Dielectric Packing
Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.229mm (average) and 0.178mm (at any point). While, for the jacket is 0.127mm (average) and 0.076mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- Stranded bare/tinned annealed conductor. - Internal wiring or external interconnection- 100% Aluminium mylar shield with drain wire. of computers and electric business- Tinned copper braid shield with 85% coverage. machines.- Colour-coded PVC jacketed.- Rating temperature : 80°C- Rating voltage : 30V- Flammability : UL VW-1
Construction and Characteristics :
Three 28AWG video coaxial cable plus four 24AWGcontrol lines with overall Aluminium mylar shield and tinned copper braid shielding 85% coverage.PVC jacketed.
Three 28AWG video coaxial cable plus eight 24AWG control lines with overall Aluminium mylar shield and tinned copper braid shielding 85% coverage.PVC jacketed.
One pair of 28AWG signal wires (HDPE insulated)plus one pair of power wires (semi-rigid PVC insulated28 ~ 20AWG) with overall Aluminium mylar shield and tinned copper braid shielding 65% min. coverage.PVC jacketed.
UL 2960 SUPERCOMALMulti Conductor Cable
Features : Application :- Bare/Tinned annealed, stranded or solid conductor. - Internal wiring of electronic equipment- Multi-conductor Polypropylene insulated. such as computers and electric business- 100% Aluminium mylar shield with drain wire. machines.- Colour-coded PVC jacketed.- Rating temperature : 60°C- Rating voltage : 30V- Flammability : UL VW-1
Construction and Characteristics :
Conductor Insulation Jacket Max. cond. Min. ins. Dielectric Packing
37 7.43 1.03 9.50 Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.152mm (at any point). While, for the jacket is 0.762mm
(average) and 0.610mm (at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Stranded(Bare)
or(Tinned)
1000Ft(305M)
or
500ft(153M)
AWM 2990 E151684 VW-1SC 80°C 30V **AWG SUPERCOMAL
Insulation
Aluminium mylar foilJacket
Drain wire
Conductor
Coaxial Cable SUPERCOMALWith two layer braiding
Features : Application :- Solid, Stranded bare annealed copper. - For internal wiring and connection- Polyethylene insulated. of high frequency equipment.- Overall bare copper braid shield.- Colour-coded PVC jacketed.
Construction and Characteristics :
Conductor Insulation Braided Jacket PackingType Strand Material Nom. O.D Material Diameter Material Nom. O.D Material Length
Features : Application :- Bare/Tinned annealed , copper cald steel conductor. - For internal wiring and connection- Polyethylene or Foamed Polyethylene insulated. of high frequency equipment.- Overall tinned or bare copper braid shield.- Colour-coded PVC jacketed.
Construction and Characteristics :
Conductor Insulation Braided Jacket PackingType Strand Material Nom. O.D Material Coverage Material Nom. O.D Material Length
Features : Application :- Bare, copper cald steel conductor. - For internal wiring and connection- Polyethylene insulated. of high frequency equipment.- Overall bare copper braid shield.- Colour-coded PVC jacketed.
Construction and Characteristics :
Conductor Insulation Braided Jacket PackingType Strand Material Nom. O.D Material Diameter Material Nom. O.D Material Length
Features : Application :- Bare, copper cald steel conductor. - For internal wiring and connection- Polyethylene insulated. of high frequency equipment.- Overall bare copper braid shield.- Colour-coded PVC jacketed.
Construction and Characteristics :
Conductor Insulation Braided Jacket PackingType Strand Material Nom. O.D Material Diameter Material Nom. O.D Material Length
Features : Application :- Solid bare annealed copper. - For internal wiring and connection- Solid Polyethylene insulated. of high frequency equipment.- Overall tinned copper braid shield.- Colour-coded PVC jacketed.
Construction and Characteristics :
Conductor Insulation Braided Jacket ( P.V.C ) PackingNo. of cores Strand Material Nom. O.D Material Diameter Material Inner O.D Outer O.D Length
Features : Application :- Solid tinned annealed copper. - For internal wiring and connection- Foamed Polyethylene insulated. of high frequency equipment.- Overall bare copper braid shield.- Colour-coded PVC jacketed.
Construction and Characteristics :
Conductor Insulation Braided Jacket ( P.V.C ) PackingNo. of cores Strand Material Nom. O.D Material Diameter Material Inner O.D Outer O.D Length
Features : Application :- Solid tinned annealed copper. - For internal wiring and connection- Foamed Polyethylene insulated. of high frequency equipment.- Foil with Al-mylar Tape- Overall bare copper braid shield.- Colour-coded PVC jacketed.
Construction and Characteristics :
Conductor Insulation Braided Jacket ( P.V.C ) PackingNo. of cores Strand Material Nom. O.D Material Diameter Material Inner O.D Outer O.D Length
Features : Application :- Stranded tinned annealed conductor. - For security system and internal- Semi-Rigid PVC insulated. wiring of electronic equipments.- Chrome PVC jacketed.- Rating temperature : 80°C- Rating voltage : 30V
Construction and Characteristics :
Conductor Insulation Jacket Max. cond. Min. ins. Dielectric Packing
Remark : 1. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
24 7/0.200 95.280.61 0.15 1.00
8
6
4 3.50
4.30
4.70
0.60
3.27
2.82
2.31
4 2.77
6
8
26 7/0.160 0.49 0.18 1.20 3.39
3.92
0.50 152.21
4.20
4.90
5.40
Stranded(Tinned)
5 1000 1000Ft(305M)
Conductor Insulation
Jacket
AV SUPERCOMALLow Voltage Cable for Automobiles
Features : Application :- Stranded bare annealed copper - Wire harness for cars, motorcycles- Colour-coded PVC insulated. and motors.- Rating temperature : 105°C - Rating voltage : Not specified- Uniform thickness of wire enable easy stripping & cutting.
Construction and Characteristics :
Conductor Insulation
Conductor Insulation Packing
Nominal Cross Stranding Strand Thickness Nominal Maximum Length
sectional area (No/mm) O.D. Average O.D. O.D. per roll
(mm) (mm) (mm) (mm)
0.2 7/0.200 0.61 0.54 1.70 1.80
0.3 7/0.260 0.79 0.55 1.90 2.00
0.3f 15/0.180 0.81 0.54 1.90 2.00
0.5 7/0.320 0.98 0.61 2.20 2.40
0.5f 20/0.180 0.93 0.63 2.20 2.40 2000Ft
0.75f 30/0.180 1.14 0.63 2.40 2.60
0.85 11/0.320 1.23 0.63 2.50 2.60 (610M)
0.85f 16/0.260 1.20 0.65 2.50 2.60
1.25 16/0.320 1.48 0.61 2.70 2.90
1.25f 50/0.180 1.47 0.61 2.70 2.90
2.0 26/0.320 1.88 0.66 3.20 3.40
3.0 41/0.320 2.37 0.76 3.90 4.10
Remark : 1. "f" means "flexible" 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
(mm²)
SUPERCOM AV **mm²
AVS SUPERCOMALLow Voltage Cable for Automobiles
Features : Application :- Stranded bare annealed copper - Wire harness for cars, motorcycles- Colour-coded PVC insulated. and motors.- Rating temperature : 105°C - Rating voltage : Not specified- Uniform thickness of wire enable easy stripping & cutting.
Construction and Characteristics :
Conductor Insulation
Conductor Insulation Packing
Nominal Cross Stranding Strand Thickness Nominal Maximum Length
sectional area (No/mm) O.D. Average O.D. O.D. per roll
(mm) (mm) (mm) (mm)
0.3 7/0.260 0.79 0.50 1.80 1.90
0.3f 15/0.180 0.81 0.49 1.80 1.90
0.5 7/0.320 0.98 0.51 2.00 2.10
0.5f 20/0.180 0.93 0.53 2.00 2.10 2000Ft
0.75f 30/0.180 1.14 0.48 2.10 2.20
0.85 11/0.320 1.23 0.48 2.20 2.30 (610M)
0.85f 16/0.260 1.20 0.50 2.20 2.30
1.25 16/0.320 1.48 0.51 2.50 2.60
1.25f 50/0.180 1.47 0.51 2.50 2.60
2.0 26/0.320 1.88 0.51 2.90 3.10
2.0f 37/0.260 1.83 0.53 2.90 3.10
Remark : 1. "f" means "flexible" 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
(mm²)
SUPERCOM AVS **mm²
AVSS SUPERCOMALLow Voltage Cable for Automobiles
Features : Application :- Stranded bare annealed copper - Wire harness for cars, motorcycles- Colour-coded PVC insulated. and motors.- Rating temperature : 105°C - Rating voltage : Not specified- Uniform thickness of wire enable easy stripping & cutting.
Construction and Characteristics :
Conductor Insulation
Conductor Insulation Packing
Nominal Cross Stranding Strand Thickness Nominal Maximum Length
sectional area (No/mm) O.D. Average O.D. O.D. per roll
(mm) (mm) (mm) (mm)
0.3 7/0.260 0.79 0.35 1.50 1.60
0.3f 15/0.180 0.81 0.34 1.50 1.60
0.5 7/0.320 0.98 0.36 1.70 1.80
0.5f 20/0.180 0.93 0.38 1.70 1.80 2000Ft
0.75f 30/0.180 1.14 0.33 1.80 1.90
0.85 11/0.320 1.23 0.33 1.90 2.00 (610M)
0.85f 16/0.260 1.20 0.35 1.90 2.00
1.25 16/0.320 1.48 0.36 2.20 2.30
1.25f 50/0.180 1.47 0.36 2.20 2.30
2.0f 37/0.260 1.83 0.43 2.70 2.80
Remark : 1. "f" means "flexible" 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs ( 50 Pairs ) and vertical distribution, plenum and riser.
- 16.70mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- Packing method as per customer requirements.
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Impedance
Structural Return Loss (dB min.)
Attenuation (dB max.)
Delay (ns max.)
Skew (ns max.)
Near End Crosstalk (dB min.)
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs ( 75 Pairs ) and vertical distribution, plenum and riser.
- 19.60mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- Packing method as per customer requirements.
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Impedance
Structural Return Loss (dB min.)
Attenuation (dB max.)
Delay (ns max.)
Skew (ns max.)
Near End Crosstalk (dB min.)
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs ( 100 Pairs ) and vertical distribution, plenum and riser.
- 22.30mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- Packing method as per customer requirements.
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Impedance
Structural Return Loss (dB min.)
Attenuation (dB max.)
Delay (ns max.)
Skew (ns max.)
Near End Crosstalk (dB min.)
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- Overall Al-mylar foil with 24AWG drain wire.- 5.80mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Stranded bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- Overall Al-mylar foil with 24AWG drain wire.- 5.80mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Rating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- 5.20mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Stranded bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- 5.20mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Rating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- Overall Al-mylar foil with 24AWG drain wire- 5.80mm PVC / LSZH-FR jacketed.- Colour-coded jacketed.- Rating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box.
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Near End Crosstalk (dB min.) 64 62 53 48 47 44 42 41 39 35 32
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Stranded bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- Overall Al-mylar foil with 24AWG drain wire.- 5.80mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Rating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box.
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Near End Crosstalk (dB min.) 64 62 53 48 47 44 42 41 39 35 32
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- 5.20mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Near End Crosstalk (dB min.) 64 62 53 48 47 44 42 41 39 35 32
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs ( 25 Pairs ) and vertical distribution, plenum and riser.
- 12.00mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- Packing method as per customer requirements.
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Near End Crosstalk (dB min.) 64 62 53 48 47 44 42 41 39 35 32
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 24AWG Stranded bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- 5.20mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Rating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Near End Crosstalk (dB min.) 64 62 53 48 47 44 42 41 39 35 32
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 23AWG Solid bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- 6.20mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Impedance
Return Loss (dB min.)
Attenuation (dB max.)
Delay (ns max.)
Skew (ns max.)
Near End Crosstalk (dB min.)
PSNEXT (dB min.)
ELFEXT (dB min.)
PSELFEXT (dB min.)
LCL (dB min.)
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Features : Application :- 23AWG Stranded bare annealed conductor - For voice, data, video and low voltage control- Solid Polyethylene Insulated. It fits in all LAN topologies including horizontal - Twisted pairs and vertical distribution, plenum and riser.
Pair 1 : Blue + White/BluePair 2 : Orange + White/OrangePair 3 : Green + White/GreenPair 4 : Brown + White/Brown
- 6.20mm PVC / LSZH-FR Compound jacketed.- Colour-coded jacketed.- Operating temperature : -20°C to +80°C- Cadmium & Lead Free ( < 5ppm )- 305m per Box
Construction and Characteristics :
Testing Standard (TIA/EIA-568-B.2) ** 100 meter at 20°C **
Impedance
Return Loss (dB min.)
Attenuation (dB max.)
Delay (ns max.)
Skew (ns max.)
Near End Crosstalk (dB min.)
PSNEXT (dB min.)
ELFEXT (dB min.)
PSELFEXT (dB min.)
LCL (dB min.)
Remark : 1. Under UL Subject 444, the minimum thickness for insulation is 0.178mm (average) and 0.152mm (at any point). While, for the jacket is 0.508mm (average) and 0.406mm(at any point).
2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
Application :- The tubing is intended for use in damp or dry locations to insulate bare live parts or to supplement existing insulation in electrical equipment.
Rating :- SAC-300:- suitable used for 105°C 300V maximum.- SAC-600:- suitable used for 105°C 600V maximum.
** W-A = outdoor use Remark : 1. Under UL Subject 758, the minimum thickness for insulation is 0.762mm (average) and 0.686mm (at any point). While, for
the jacket is 0.762mm (average) and 0.584mm (at any point). 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
1000ft(305M)
2000
Conductor
Insulation
Jacket
Jacket
Fillers
Seperator
Conductor
Fillers
Insulation Aluminium mylar foil
Braided wire
Drain wire
UL SJT W-A E151685 **°C VW-1 SUPERCOMAL CSA TYPE SJT LL96647 **°C FT2 -F-
UL SJT E151685 **°C VW-1 SHIELDED SUPERCOMAL CSA TYPE SJT LL96647 **°C FT2 SHIELDED -F-
Features : Application :- Stranded bare annealed conductor. SPT-1 - For use in household clocks, fans, - PVC insulated. radios and similar appliances.- Rating temperature : 60°C or 105°C SPT-2 - For heavier construction than SPT-1- Rating voltage : 300V SPT-3 - For heavy-duty use in damp locations;- Flammability : UL VW-1 / CSA FT2 / Japan -F- especially for refrigerators and room-
size air conditioners.
Construction and Characteristics :
Conductor Insulation Max. cond. Min. ins. Dielectric Packing
Remark : 1. Under UL Subject 62, the minimum thickness of SPT-1 is 0.762mm (average) and 0.686mm (at any point); SPT-2 is 1.14mm
and 1.02mm respectively; SPT-3 is 1.52mm and 1.37mm for 18 - 16AWG and 2.03mm and 1.83mm for 14AWG. 2. If you have special technical requirements, please inform us. Meet and exceed customer expectation is our commitment.
SPT-1
SPT-2
SPT-3
1000ft(305M)
or
2000ft(610M)
UL SPT-* E151685 **°C VW-1 SUPERCOMAL CSA TYPE SPT-* LL96647 **°C FT2 -F-
UL SPT-* E151685 **°C VW-1 SUPERCOMAL CSA TYPE SPT-* LL96647 **°C FT2 -F-
ConductorJacket
ConductorJacket
Insulation
Telephone Cables SUPERCOMAL
Features : Application :- Solid Tinned annealed conductor - For internal distribution telephone Cables- Polyvinyl Chloride Insulated.- Twisted pairs and colour code.
- Colour-coded PVC jacketed.- Rating temperature : -20°C to +70°C
Construction and Characteristics :
Conductor Insulation Jacket Nominal Packing
Type Pairs Stranding Thickness Nominal Thickness Nominal Capacitance Length(No/mm) Any Point O.D. Average O.D. pF / 500m per roll
mm mm mm mm
Solid 2 1 / 0.500 0.15 0.93 0.40 3.50
Solid 3 1 / 0.500 0.15 0.93 0.50 5.30
Solid 4 1 / 0.500 0.15 0.93 0.50 5.80
Solid 5 1 / 0.500 0.15 0.93 0.60 6.50
Solid 10 1 / 0.500 0.15 0.93 0.60 7.60
Solid 25 1 / 0.500 0.15 0.93 0.80 11.20
Solid 50 1 / 0.500 0.15 0.93 0.80 17.20
1000ft (305M)
1st 2nd 3rd 4th 5th6th 7th 8th
1000ft (305M)
1000ft (305M)
1000ft (305M)
1000ft (305M)
1000ft (305M)
11th 12th 13th 14thYellow 20th
21st 22nd 23rd 24th 25th16th 17th 18th
Violet
Blue with Orange with Green withwire A liningwire A liningwire A lining
Application :- The tubing is intended for use in damp or dry locations to insulate bare live parts or to supplement existing insulation in electrical equipment.
Rating :- SAC-300:- suitable used for 105°C 300V maximum.- SAC-600:- suitable used for 105°C 600V maximum.
Features : Application :- Stranded tinned annealed conductor - For connecting the computer peripherals- Twisted pairs to computer easily without having to reboot
Signal wires : Green, White or run setup. 28AWG HDPE insulated.
Power wires : Black, Red 28~20AWG Semi-rigid PVC insulated.
- 100% Aluminium mylar shield with drain wire.- Tinned copper braid shield with 65% coverage.- Colour-coded PVC jacketed.
Construction and Characteristics :
Signal wires (28AWG)
Aluminium-mylar tape
Drain wire
Braided wire
Power wires (20~28AWG)
Jacket
Testing Standard : Universal Serial Bus Specification Rev. 2.0